23-101690City of Federal Way
Community Development Dept,
33325 8th Ave Y
Federal Way, WA 98003
[Ph:(253)835-2607 Fax: (253) 835-2609
FINALED
Building - Single Family
Permit #:23-101690-00_SF
Inspection Request Line: (253) 835-3050
Project Name: THE WOODLANDS AT REDONDO CREEK LOT 27
Project Address: 30122 19TH AVE S
Parcel Number: 95265 ] 0270
Project Description: BLUEBEAM - Construction of a 2535 square foot, 2-story, single family residence with a 60
square foot covered entry, and a 421 square foot attached garage. Includes plumbing and
mechanical.
Owner
SSHI LLC DBA D R HORTON
11241 SLATER AVE NE SUITE 12C
KIRKLAND WA 98033
Applicant
JESS BOSANCUD R HORTON
11241 SLATER AVE NE SUITE 120
KIRKLAND WA 98033
Contractor
D R HORTON
11241 SLATER AVE NE SUITE 120
KIRKLAND WA 98033
Census Category: 101 - New Single Family House
Additional Permit Information
New / Additional Sq. Feet - I st Floor .....................
1 139
New / Additional Sq. Feet - 3rd Floor .....................
0
New / Additional Sq. Feet - Basement ....................
0
Occupancy #1 - Construction Type .........................
Type V - B
New / Additional Sq. Feet - Garage ........................
421
Plumbing Work, Veil nation? .....................................
25000
Number of Stories ...................................................
2
Plumbing to be Included? ........................................
Yes
Will Certificate of Occupancy be Issued? ...............
Yes
Comprehensive Plan Designation................... ....
SF - High -Density
Total Valuation: 442,822.99
Residential
Lender
OWNER FINANCED
New / Additional Sq. Feet - 2nd Floor ....................
1396
Occupancy # I - Area (Sq. Feet)....... .......................
2535
BasicPlan?...........................................................
No
New / Additional Sq. Feet - Deck ...,......'.•'...,...,,.,
0
Mechanical to be Included?..... ................................
Yes
Mechanical Work Valuation? ..................................
20000
New / Additional Sq. Feet - Other ...........................
60
New / Additional Sq. Feet - Total ....... »....... 4...... .
3016
Occupancy # 1 - Use ................................................
Residence (1 or 2
family)
Zoning Designation.......................4.........................
RS 5.0
Mechanical Fixtures
Ducting 1 Fans
Gas Piping 1 Gas Pipe Outlets
Plumbing Fixtures
Bathtubs 2 Dishwashers
Lavatories 4 Showers
Water Closets 3 Water Heaters
6 Furnaces I
2
1 Laundry Washer Outlets 1
2 Sinks 1
1 Hose Bibbs 2
Public Works: CONDITIONS:
1. All damaged sidewalks due to construction shall be repaired prior to occupancy.
2. All erosion control measures shall be installed prior to any inspection and shall be maintained
throughout the course of construction.
PERMIT EXPIRES Tuesday, 7 May, 2024
Permit Issued on Thursday, November 9, 2023
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use with the Federal laws, ways and regulations of the State of
Washington and the
-- Date:
Owner or agent:
City of Federal Way
Certificate of occupancy
This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section
R110 of the International Residential Code is certifying that at the time of issuance, this structure was in
compliance with the various ordinances of the City regulating building construction or use. This certificate is valid
ONLY when ersdorsed b Citr staff.
Tenant Name: THE WOODLANDS AT REDONDO CREEK LOT Permit # 23-101690-00-SF
Address: 30122 19TH AVE S
Includes:
#1 #2 #3 #4
Occupancy Class: R-3
Construction Type: Type V - B
Occupancy Load:
Floor Area (sq. ft.) 2,535.00
Owner Name: SSHI LLC DBA D R HORTON
Owner Address: 11241 SLATER AVE NE SUITE 120
KIRKLAND WA 98033
Date
Building Official
The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
experience has shown as s reasonably rely epossible ct the e(within budgetary tialth and safety of �ir:e and pers ne general 1nef ICJ tat ansJ, thelthough the n City r+e+thoty has sg guaranas cotee
a review and inspection
nornos re the owner/
of the Cityant or to any 0or the State of Washington ther person haffectr g he coat this [nstnrction or use of said istructure or the !arid upon
whihordinanceg
which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises.
r
A��
clrY of
Federal Way
THIS CARD IS TO REMAIN ON -SITE
Construction Inspection Record
INSPECTION REQUESTS: (253) 835-3050
PERMIT #: 23 101690 00 Address: 30122 19TH AVE S
Project: SSHI LLC dba D R HORTON FEDERAL WAY WA 98003
Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card.
ED
SWM Precon Site Mtg (4400)
El
Site Assessment (Erosion) (4365)
El
Footings/Setback (4110)
Approved
To be done PRIOR to breaking ground
Approved to place concrete
By
Date
By
Date
By
Date 1 ?/ 4/
® Foundation Wall (4115)
Drainage/Downspout (4040)
Plumbing Groundwork (4190)
Approved to place concrete
Approved to backfill
Approved to cover
By Date i 1-tP
By Date I $ Z Y
By Date I'Ir Z¢
Q Slab/Concrete Floor (4255)
El Underfloor Framing (4285) QP
Floor Sheathing (4105)
Approved to place concrete
Approved to sheath floor
Approved to install flooring
By Date
By Date 7. I,L4—
By Date
10 Shear Walls (4245) 0 Roof Sheathing (4220) l2 Rough Plumbing (4230)
Approved to install siding Approved to install roofing Approved
By Date %i 1 (Z� By Date Vt l'By Date 2,1 W1W
13 Mechanical Rough -in (4165)
14 Gas Piping (4125)
15 Fire/Draft Stops (4095)
�/�,� Approved _ r
WIv ' ''! I"Pt -�
,�,' Approved to release test f
By IVY Date '-1. %*I ?-*
Approved
By Date 1-1 (%C
By Date
1 S Interim Erosion Control (4370) Prior to scheduling a Framing inspection; 17 Framing (4120)
Approved Electrical, Plumbing & Mechanical Rough -in Approved to insulate
and Fire/Draft Stop inspections must be signed -
By Date off and approved. IBC 109.3.4 By 06 Date ZJ 7,61Z*
Is Insulation (4150)
19 Gypsum Wallboard Nailing (4130)
Final Erosion Control (4375)
A proved to install wallboard
Approved to install mud & tape
Approved
By 1`"v Date 7/�zl/ZA--
By Date LIZG%�"
By Date
l Final - Mechanical (4065) 22 Final - Plumbing (4075) 23 Final - Building (4050)
Approved Approved Approved
By 44 Date By (V14— Date By Date /VZs(z_v
-oi(-- (l Ll L�
Vriglff ni- O�- i 1z (v4—
w flt q rntir-4 - C�jr— tl Jzk P*f
&,�,t, vwjrr__ crl- iWA9
o IL,o $*Wry WVULrSVW- VA A Itwls*
❑
Rough Electrical
Final Electrical
Right of Way
Approved
Approved
Approved
By
Date
By
Date
By
Date
ADDRESS:
CITY OF Building Division
I deral Eighth Avenue South
Fedar� Way
Federal 07 Fax
98835-6325
Phone 253-835-2607 Fax 253-835-2609
CORRECTION NOTICE
50 ( Z2-
't f-- Ovvr-
IF YOU HAVE QUESTIONS CALL
PERMIT#:
(253) 835-
WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD
FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS.
L t =, _ Ar�
DATE INSPECTOR
DO NOT REMOVE THIS NOTICE
Page of
r
s
CITY OF
Federal Way
Building Division
33325 Eighth Avenue South
Federal Way, WA 98003-6325
Phone 253-835-2607 Fax 253-835-2609
CORRECTION NOTICE
ADDRESS: I z2 I cl t` A-1� S PERMIT#:__:�.-
,i.t_ P 4- —
IF YOU HAVE QUESTIONS CALL I CV6, (253) 835- �Z(
WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD
FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS.
v(r(-1,*- 0
DATE INSPECTOR
DO NOT REMOVE THIS NOTICE
Page of
CITY OF Building Division
33325 Eighth Avenue South
Federal
Way Federal Way, 98-6325
Phone 253-835-2607 Faxx 253-835835-2609
CORRECTION NOTICE
ADDRESS: 3012'Z l�l+" s PERMIT#: 7-3- I01 G9D
bts Prrkzf',3 ipr-n c- c
� SiG}tt� R�F�Cz l.i.r-+ic.5 /cr�� Zx C.�L�n+ off= 1E�lY�I.LR'1—
Ana v. +—*�i_
i�uA rf� VI-Sflf Pr r-�4 7n Expp"JSWn+ TrtgJiL—
vJ ►�2— ?a
t�
rf
i
IF YOU HAVE QUESTIONS CALL --Mk
(253) 835- 1-62-
WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD
FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS.
DATE INSPECTOR
EEO NOT REMOVE THIS NOTICE
Page of