Loading...
23-101750-CarmonaInterior-4-10-23PROJECT DATA I PROPERTY DATA I ENERGY DATA TRUST CONTACT PROJECT ADDRESS PRESCRIPTIVE OPTION (ENERGY CREDIT 1A) CARMONA FAMILY TRUST (BECU) 30104 17TH AVE SW CONTACT: RACHELLE CZAPLINSKI (206 439 5746) FEDERAL WAY, WA 98023 INSULATION VALUES RACHELLE.CZAPLINSKI@BECU.ORG SLAB PERIMETER (FIRST 24") R-10 ZONING DESIGNATION BELOW GRADE WALLS (EXTERIOR) R-10 RESIDENT CONTACT RS15.0 BELOW GRADE WALLS (INTERIOR) R-21 SHEILA CARMONA (206 660 3197) ABOVE GRADE WALLS R-21 CARMONS939@GMAIL.COM HEIGHT LIMIT FLOORS R-30 30104 17TH AVE SW 30' (UNCHANGED) ATTICS W/ 1" CLEAR VENT SPACE R-49 FEDERAL WAY, WA 98023 ADV FRAMED ATTICS W/ 1" CLEAR R-38 SETBACKS VAULTED JOISTS/RAFTERS R-38 ARCHITECT FRONT: 20' JOSH PS SIDE: 5' FENESTRATION U-0.28 5406 SW BEACH DRIVE TER REAR: 5' OVERHEAD GLAZING U-0.50 SEATTLE, WA 98116 SDCI ID: AC58960 LOT AREA CONTACT: S. JOSHUA BRINCKO (206 708 9933) 52,174 SF JOSH@JOSHARCH.COM ASSESSOR'S TAX NUMBER STRUCTURAL ENGINEER 005070-0100 SWENSON SAY FAGET 2124 3RD AVE #100 LEGAL DESCRIPTION SEATTLE, WA 98121 ADELAIDE FOREST ESTATES CONTACT: KARL ROSMAN (206 443 6212) PLAT BLOCK: N/A KROSMAN@SWENSONSAYFAGET.COM PLAT LOT: 10 CONTRACTOR OWNER CONSTRUCTION DATA VENTILATION DATA SCOPE OF WORK SYSTEM DESIGN ADA UPGRADES INCLUDING ADDITION OF RAMPS AND ELEVATOR & BATHROOM THIS SYSTEM IS DESIGN/BUILD (IRC CH. 15) RETROFIT SYSTEM CRITERIA AREA SUMMARY MINIMUM OF .35 AIR EXCHANGES PER HOUR FOR ALL HABITABLE ROOMS. CONDITIONED SPACE (UNCHANGED) MAXIMUM OF .50 AIR EXCHANGES PER HOUR LOWER LEVEL 2,960 SQ FT FOR ALL HABITABLE ROOMS. MAIN LEVEL 2,960 SQ FT TOTAL 5,920 SQ FT SYSTEM COMPONENTS UNCONDITIONED SPACE TIMER LOWER LEVEL 0 SQ FT INTAKE GRILL & DUCTING (FROM EXTERIOR) MAIN LEVEL (GARAGE) 1,466 SQ FT MOTORIZED DAMPER TOTAL 1,466 SQ FT ELECTRIC AIR TEMPERING UNIT INTAKE BLOWER LOT COVERAGE L DISTRIBUTION DUCTING (HABITABLE ROOMS) RESIDENCE &GARAGE 4,426 SQ FT DISTRIBUTION GRILLS (HABITABLE ROOMS) POOL, DRIVE, WALKWAYS ETC 7,183 SQ FT ELECTRIC EXHAUST FAN TOTAL 11,609 SQ FT EXHAUST DUCTING LOT AREA 52,174 SQ FT EXHAUST PORT WITH BACK DRAFT DAMPER COVERAGE CALC: 50%(52174) = 26,087 SFT SYSTEM FUNCTION ALLOWABLE COVERAGE 26,087 SQ FT PROPOSED COVERAGE 11,609 SF INTAKE BLOWER, AIR TEMPERING UNIT, AND EXHAUST FAN TO BE CONNECTED TO TIMER FOR SYNCHRONIZED, INTERMITTENT USE THROUGHOUT EACH DAY. FRESH AIR FROM THE EXTERIOR IS PULLED THROUGH AIR TEMPERING UNIT, THEN DISTRIBUTED THROUGH DUCTING TO ALL HABITABLE ROOMS. A BALANCED QUANTITY OF AIR IS SIMULTANEOUSLY EVACUATED FROM THE INTERIOR W/ THE EXHAUST FAN DUCTED TO EXT TABLE OF CONTENTS SHT DESCRIPTION SHT DESCRIPTION (TBD) A1.0 SITE PLAN + PROJECT INFORMATION S1.1 GENERAL NOTES A1.0A FULL SITE PLAN S2.1 FOUNDATION PLAN A1.1 GENERAL NOTES S2.2 MAIN FLOOR FRAMING PLAN N/A SURVEY S2.3 ROOF FRAMING PLAN A2.0 MAIN FLOOR PLAN S3.1 FOUNDATION DETAILS A2.1 LOWER FLOOR PLAN S4.1 WOOD FRAMING DETAILS A2.2 ELEVATOR INFO 5 a ry 3d�h Pj SW 390Fh P, s W 3pah ar �3010417th N Avenue Southwest � a n O � N N a sw301stsr sw301scsi sw3airsi N b 5 � a J 3 n y d N Y 4 � � N y g � n Go,le RESCUE ECTED ECTION. ,ED IN THIS •7244 ire.org 23-101750-00-S F J O S H ARTISAN + ARCHITECT 206 708 9933 JoshArch.COM All drawings, specifications, plans, ideas, arrangements, and design solutions represented or referred to are the property of and owned by Josh PS whether the project for which they are made is executed or not. They were created, evolved, developed and produced for the sole use on and in connection with this project and none of the above may be disclosed or given to or used by any person, firm, or corporation for any use or purpose whatsoever including any other project, except upon written permission of Josh PS. COPYRIGHT 2018 © JOSH PS 9388 REGISTERED ARCHITECT S. JOSHUA BRINCKO STATE OF WASHINGTON DESIGN SJB DRAWN CEC CHECKED SJB DATE [2018-0314 DESIGN] [2018-0725 PERMIT] CARMONA INTERIOR ONLY 30104 17TH AVE SW FEDERAL WAY, WA 98023 UAWT IIIIIIIIII SITE PLAN PROJECT INFORMATION Al 00 VICINITY MAP NOT TO SCALE CITY OF FEDERAL WAY PARTIAL SITE PLAN (TO BE VERIFIED IN FIELD) COMMUNITY DEVELOPMENT SCALE: 1/8" = 1'-0" TRUE NORTH 23-101750-00-S F J O S H ARTISAN + ARCHITECT 206 708 9933 JoshArch.COM %`g%" rf e a '! \ Vim\ •• ' • � •�.• • •� �•. WON\ .., ••j•. •.• •••'• .. �`. ...•. ...S Y• / •�Q'F�ON� SETBACK. .• / 7"DEC SEN •• •�� •�� DEC6 TEL SENTRY i a 4•' • '��2 22" CED �• OL �BO FULL SITE PLAN (TO BE VERIFIED IN FIELD I I I I I *NOTE: ALL TREES TO BE RETAINED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT All drawings, specifications, plans, ideas, arrangements, and design solutions represented or referred to are the property of and owned by Josh PS whether the project for which they are made is executed or not. They were created, evolved, developed and produced for the sole use on and in connection with this project and none of the above may be disclosed or given to or used by any person, firm, or corporation for any use or purpose whatsoever including any other project, except upon written permission of Josh PS. COPYRIGHT 2018 © JOSH PS 9388 REGISTERED ARCHITECT VS. JOSHUA BRINCKO STATE OF WASHINGTON DESIGN SJB DRAWN CEC CHECKED SJB DATE [2018-0314 DESIGN] [2018-0725 PERMIT] CARMONA INTERIOR ONLY 30104 17TH AVE SW FEDERAL WAY, WA 98023 FULL SITE PLAN TRUE NORTH ■ SCALE: 1/16" = 1'-0"