Loading...
21-104292 -Water System Hydraulic -10-14-2021-V1Lakehaven WATER & SEWER DISTRICT Hydraulic Model Fire Flow Estimate Request/Reporting Form RECEIVED Nov 19 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Requested By: Federal Way Public Schools Date: 11/24/2020 Location to be Modeled: Olympic View K-8 School / 1321039008 (Proposed Improvements) Lakehaven %4 Section Grid: E/9 intersection: SW 327t' St & 26th Ave SW Add. Description: See attached map Pressure zone: 538 Results By: Date: Model Run No.: John Bowe 12/04/2020 Master Water System Model 2007.net FF #417 Condition Pressure (psi) Flow (gpm) Static 85 0 Fire Flow 20 4500 NOTES: Lakehaven's adopted level of service goals for fire flow rates are 1000 gpm within single family residential areas (including duplexes) and 2500 gpm for multi -family, commercial, industrial areas. Model results depict the theoretical performance of the water system under high demand conditions and are not guaranteed to represent actual system performance. A design professional should be consulted for site specific design purposes. The calculated fire flow capacity in the above table is based on a currently available residual system pressure of 20 psi at the location modeled. The model indicates that Lakehaven's standard maximum allowable velocity of 10 ft/s is exceeded at a fire flow rate above 2300 gpm. Fire flow capacities greater than 2300 gpm may be accommodated through water system improvements. 12042OFF 417 - Olyimpic View Elm (Form Update 1/6/17) The above model run assumed an 8" diameter pipe loop across the property with no off -site improvements. No hydrant locations were provided, so a test point was assumed near the center of the property. A portion of the proposed on -site piping also reach the maximum design velocity for new main of 8 ft/s. To achieve a fire flow greater than the requested 2750 gpm, on -site and off -site improvements would be needed. Option 1: On -site mains assumed at 12" diameter. Off -site improvements increased sections A and B (�530 ft) to 8" diameter. This run provided a maximum of 3100 gpm without exceeding system velocities (6000 gpm at 20 psi). Option 2: On -site mains assumed at 12" diameter. Off -site improvements increased sections B, C and D (�630 ft) to 8" diameter. This run provided a maximum of 2800 gpm without exceeding system velocities (5900 gpm at 20 psi). Option 3: On -site mains assumed at 12" diameter. Off -site improvements increased sections A, D, and E (�860 ft) to 8" diameter. This run provided a maximum of 3100 gpm without exceeding system velocities (6000 gpm at 20 psi). 120420FF 417 - Olyimpic View Elm (Form Update 1/6/17)