Loading...
10-103106 ' •i ELettrical City of Federal Way Community Development Services Permit #: 10-103106-00-EL P.O.Box 9718 Federal Way,WA 98063-9718 Ins Inspection Request Line: (253) 835-3050 Ph:(253)835-2607 Fax:(253)835-2609 FILE -1301 � P q Project Name: FEDERAL WAY MARKET PLACE Project Address: 34624 16TH AVE S Parcel Number: 250090 0080 Project Description: Installing conduit in u/g trench from transformer on the Chase Bank site to the new pad to the north of the Chase Bank site. Owner Applicant Contractor MARKETPLACE WEST FEDWAY FOX ELECTRIC FOX ELECTRIC 3700 BEAZER RD PO BOX 630 FOXELC*278DA(8/30/10) BELLINGHAM WA KENT WA 98032 PO BOX 630 98226-8835 KENT WA 98032 '46ab'r.. ....�•....��;; ,.< h». �„air>R..�. 4 _ ,� r�,...�iw. ,.� ,.:.:• Is Use Educational or Institutional? No Service greater than 999 Amps9 No �g • • s C s � • G PERMIT EXPIRES Friday, July 22, 2011 Permit Issued on Thursday, July 22, 2010 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the us w.I b in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date: 7/2 Z"/$ �� /zCO/io - THIS CARD IS TO MAIN ON-SITE , . . • CITY OF • Construction In ction Record ` ` ' Federal Way INSPECTION REQU TS: (253) 835-3050 PERMIT#: 10-103106-00-EL Address: 34624 16TH AVE S Owner: MARKETPLACE WEST FEDWAY FEDERAL WAY, WA 98003 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. DI UFER Ground (4295) CI Ditch cover(4030) ❑ Slab/Concrete Floor(4255) Approved Approved Approved to place concrete By Date By . c Date n _ a 6.� By Date o Pool Bonding(4195) ❑ Temporary Power(4275) ❑ Service(4235) Approved Approved Approved By Date By Date By Date ❑ Feeders/Sub-panels(4045) ❑ Rough Electrical(4225) ❑ Ceiling Cover(4020) Approved Approved Approved By Date By Date By Date El Final-Electrical (4055) Approved By ac4,4_, Date() ____0_33,t,6 ❑ Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date ti 0 s I ..k CITY OF 1i s _ ( 3 ( V Ce Fe �` `� ELECTRICAL .uL %2 2o1PERMIT APPLICATION npgg Y rtf F . fi�t'?r la permits mav be obtained on-line at www cityo federalway corn** L. SITE ADDRESS: Qt �' 1 ` SUITE/UNIT/SPACE# ASSESSOR'S TAX/PARCEL# CURRENT/PROPOSED USE PROJECT NAME (Tenant or Homeowner Last Name) akr-Pea/9.y /114/2-err f161 C).7i/JD 'ko Y P✓C Co_ »vctc M (J 41- PROJECT DESCRIPTION visri,v4.) or_6x go ' 7b- Fit)rvrtipo Detailed description of work to be included on this permit only -$A, - '' . 3'3 .FEOPL EF ,.,. ..,.' ». . . ',,,v2.-:,-;-, .., l. _, NAME PRIMARY PHONE PROPERTY OWNER GO/Z -7-2 ej iU LI J Cm C03)23 2 7J MAILING ADDRESS S E-MAIL 3(// $'f 2© /it c)-( s'v 1 i£ 3oo FM TZ.,i) STATEW97202 ( ) FAX NAME PRIMARY PHONE MMAAIIix 1G �le ( C- ( ) _ -77-0ADDRESSE-MAIL I(�/ C ELECTRICAL fl x i 0 CONTRACTOR CITY STATE ZIP FAX KC'UT-- IM ?d C ( ) WA STATE CONTRACTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE# Foxc-c,e ' 279 J)n i/ o i 10 l �-J - oo ,> o69i3tCL no- l3MM �` PRIMARY PHONE aG APPLICANT p ex._ ( ) - MAILWO ADD / E-MAIL re) Gx. : ro..,id aro)c Erg(c, J 7- CITY STATE ZIP FAX KS")T w4- 91a3sr ( ) - PROJECT CONTACTC rAm AA€e PRIMARY PHONE 7:4,v I cert{lg under penalty of perjury that I am the property owner or authorised agent of the property owner.I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorised by the issuance of a permit.I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city - apart of this application. / SIGNATURE: / DATE 7/Z 2 / v PRINT NAME: . 33325 8th Avenue South•PO Box 9718♦Federal Way•WA•98063-9718♦253-835-2607•fax:253-835-2609•www.cityoffederalway.com Bulletin#160-April 9,2010 Page 1 of 2 k:\Handouts\Electrical Permit Application • i RESIDENTI• C•MERCIAL NEW SINGLE FAMILY RESIDENCE NEW COMMERCIAL Total Square Feet 1st Service/Feeder Additional Feeders (including attached garage): 0- 100 amp x$132.50 x$ 80.50 FEES: First 1300 ft2-$122.00; 101- 200 amp x$164.00 x$103.50 Each additional 500 ft2 $39.00 201- 400 amp x$307.00 x$121.00 NEW MULTIFAMILY (3 units or more) 401- 600 amp x$358.00 x$143.50 1st Service/Feeder Additional Feeders 601- 800 amp x$463.00 x$196.00 0- 200 amp x $132.50 x $ 39.00 801- 1000 amp x$565.00 x$236.50 201 -400 amp x $164.00 x $ 80.50 Over 1000 amp x$616.00 x$328.50 401 -600 amp x $224.00 x $111.50 601 -800 amp x $287.00 x $153.50 Over 600 volts surcharge x$103.50 Over 800 amp x $410.50 x $307.00 ALTERED SINGLE or MULTI FAMILY ALTERED COMMERCIAL 1st Service/Feeder 1st Service/Feeder Additional Feeders 0- 200 amp x $101.00 0- 200 amp x$132.50 x$103.50 201 600 amp x $164.00 201- 600 amp x$307.00 x$121.00 Over 600 amp x $246.50 601- 1000 amp x$463.00 x$196.00 Over 1000 amp x$515.50 x$328.50 Added or Altered Circuits 1-4 circuits$80.50;each additional$8.00 Added or Altered Circuits 1-5 circuits$103.50;each additional$8.00 Mast or meter repair $60.50 Mast or meter repair $111.50 MANUFACTURED HOMES PLAN REVIEW FEES Service or feeder only x $ 80.50 Plan Review required only for: Service and feeder x $132.50 • New,or alteration to,service of 1,000 amps or greater • Medical/Educational/Institutional Facility $103.50 plus 35%of Permit Fee (Permit Fee x 35%= +$103.50=Plan Review Fee) Plan review for modified submittals $105.50/hour MISCELLANEOUS SERVICE/EQUIPMENT LOW VOLTAGE TEMPORARY SERVICE ❑ Fire Alarm System 1st Service/Feeder Additional Feeders ❑ Security Alarm System ❑ Voice/Data Cabling 0- 60 amp x $ 71.00 x $ 32.00 ❑ Other 61- 100 amp x $ 80.50 x $ 39.00 Area to be served by system: 101-200 amp x $103.50 x $ 51.00 1st 2,500 ft2-$71.00;each additional 2,500 ft2-$18.50 201-400 amp x $121.00 x $ 60.50 #of Thermostats 401-600 amp x $164.00 x $ 80.50 First$60.50;each additional$18.50 Over 600 amp x $184.50 x $ 92.00 #of Signs FEE CALCULATIONS First$60.50;each additional$28.50 • Fees are determined by the scope of work as indicated. • A$6.00 Automation Fee will be added to all permits. Yard Pole/meter loops/pedestal x$ 80.50 • For assistance in calculating fees or completing the Portable Generator(transfer equipment) x$101.00 application form,contact the Permit Center at Ditch cover/inspection only x$121.00 253-835-2607 33325 8th Avenue South♦PO Box 9718•Federal Way•WA•98063-9718•253-835-2607•fax:253-835-2609•www.cityoffederalway.com Bulletin#160-April 9,2010 Page 2 of 2 k:\Handouts\Electrical Permit Application