Loading...
18-105338 I f I • . . Building - Single Family, Community DevelopmentPermit #:18-145338-00-SF' 33325 8th Ave S i,)-"-Y2 N Federal Way,WA 98003kInspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax(253)835-2609 Project Name: RETREAT MEADOWS LOT 22 Project Address: 35913 2ND AVE SW Parcel Number:724290 0220 Project Description: NEW-Construction of a 3264 square foot 2-story single family residence with a 60 square foot covered entry and a 640 square foot attached garage. Includes plumbing and mechanical. ***4 Bedrooms;$350,000 Estimated Selling Price*** Owner Applicant Contractor Lender LENNAR NORTHWEST INC SPENCER FITCHLENNAR LENNAR NORTHWEST INC OWNER IS LENDER 33455 6TH AVE S SUITE I-B NORTHWEST INC 33455 6TH AVE S SUITE 1-B FEDERAL WAY WA 98003 33455 6TH AVE S UNIT 1-B FEDERAL WAY WA 98003 FEDERAL WAY WA 98003 Census Category: 101 -New Single Family House Includes: #1 #2 #3 #4 Occupancy Class: R-3 _ Construction Type: Type V-B Occupancy Load: Floor Area(sq.ft.) 3,264.00 0.00 Additional Permit Information New/Additional Sq.Feet-1st Floor 1645 New/Additional Sq.Feet-2nd Floor 1619 New/Additional Sq.Feet-3rd Floor 0 Occupancy#1-Area(Sq.Feet) 3264 New/Additional Sq.Feet-Basement 0 Basic Plan? No Occupancy#1-Construction Type Type V-B New/Additional Sq.Feet-Deck 0 New/Additional Sq.Feet-Garage 420 Mechanical to be Included? Yes Plumbing Work Valuation'? 20000 Mechanical Work Valuation? 10000 Number of Stories 2 New/Additional Sq.Feet-Other 180 Plumbing to be Included? Yes New/Additional Sq.Feet-Total 3864 Will Certificate of Occupancy be Issued' Yes Occupancy#1-Use Residence(1 or 2 family) Comprehensive Plan Designation SF-High-Density Zoning Designation RS 7.2 Residential Total Valuation:428,221.00 Ducting 1 Fans 5 Fireplace Inserts 2 Furnaces 1 Gas Piping 1 Gas Pipe Outlets 5 Hot Water Tanks 1 Bathtubs 2 Dishwashers 1 Laundry Washer Outlets 1 Lavatories 5 Showers 1 Sinks 1 Water Closets 3 Hose Bibbs 2 t • • • • ., ' R'' PERMIT EXPIRES Wednesday,26 June,2019 Permit Issued on Friday,December 28,2018 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date: City of Federal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance,this structure was in compliance with the various ordinances of the City regulating building construction or use.This certificate is valid ONLY when endorsed by City staff. Tenant Name: RETREAT MEADOWS LOT 22 Permit# 18-105338-00-SF Address: 35913 2ND AVE SW Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load: Floor Area(sq.ft.) 3,264.00 0.00 Owner Name: LENNAR NORTHWEST INC Owner Address: 33455 6TH AVE S SUITE 1-B FEDERAL WAY WA 98003 „/ 6," /11 /Building Official Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible(within budgetary time and personnel limitations),the City neither guarantees ' nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises. . THIS CARD IS TO REMAIN ON-SITE • . . i& a"r"'j Construction Inspection Record F@ INSPECTION REQUESTS:(253)835-3050 PERMIT#: 18 105338 00 Address: 35913 2ND AVE SW Project: LENNAR NORTHWEST INC FEDERAL WAY WA 98023 Scheduled inspections may be failed if this cud is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right,top to bottom). Please schedule inspections as appropriate. Wolk must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 SWM Precon Site Mtg(4400) 0 Initial Erosion Control(4365) 3❑ Footinp/Setbaek(4110) Approved To be done PRIOR to breaking ground Approved to place concrete By Date By Date By ei.1 Date ( - I. El Foundation Wall(4115) ® Drainage/Downspout(4040) El Plumbing Groundwork(4190) Approved to place concrete Approved to backfill Approved to cover 4 4 i( tai,e By ; Date I f% By ' a Date l Z By �, Date i 1-3 / " ID Slab/Concrete Floor(4255) ® Underfloor Framing(4285) ® Floor Sheathing(4105) Approved to place concrete Approved to sheath floor Approved to install flooring By Date By lar.k Date 3 - By Date tM' Shear Walls(4245) M Roof Sheathing(4220) M Rough Plumbing(4230) Approved to install siding Approved to install roofing Approved 0 Date J By /IJ Date ,2- -- f' By i Date " . -- El 13 Mechanical Rough-in(4165) M Gas Piping(4125) tT3- Fire/Draft Stops(4095) C Approved Approved to release test Approved By t��)! Date • ., By Date 3 By/. 0 Date •/f, ® Interim Erosion Control(4370) Prior to aehednrrrg a Framing inspernaa; MI Framing(4120) Approved Rte' &Mecbooleal Raath-be Approved to insulate sad PIrefDrna Stop faapeettoas most be taped- BY Date off and approved. IBC 101.3.4BYZ Date �'` M Insulation(4150) El Gypsum Wallboard Nailing(4130) M Final Erosion Control(4375) Approved to install wallboard Approved to install mud&tape Approved By A Date 3 By , Date ! " / By Date • Final-Mechanical(4065) 31 Final-Plumbing(4075) ® Final-Building(4050) Approved Approved Approved / By Date S/ / By 4W Date S f l- By ' Da . (AFO' ole - 41J - )V 0 Rough Electrical 0 Final Electrical ❑ Right of Way Approved Approved Approved By Date . By • Date • By Date A..?\ RECEIVED 3265 �clrioF �" Nov t 4 tots PERMIT APPLICATION Federal Way OF FEDERAL WAY COMMUNITY DEVELOPMENT PERMIT NUMBER / 8 — / D 5 3 ..3 S - SF TARGET DATE11.1111 If SITE ADDRESS SUITE/UNIT i • 35913 2nd Ave SW Federal Way,WA PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL• $ 175,000.00 RS7.2 E( 7 2 4 2 9 0 - 0 2 2 0 TYPE OF PERMIT S BUILDING l?7 PLUMBING IJ MECHANICAL 0 DEMOLITION ❑ENGINEERING El FIRE PREVENTION NAME OF PROJECT Retreat Meadows • Build 2 story SFR 3264 Sq Ft. Lot 22 PROJECT DESCRIPTION Detailed description of work to be included on this permit only NAME PRIMARY PHONE Lennar Northwest Inc. 253-590-2215 PROPERTY OWNER E-MAIL 34556Ave S.,Unit 1-B spencer.j.fitch@lennar.com C1rr ZIP ederal Way STATE WA8003 NAME Lennar Northwest Inc. P253-590-2215 MAILING ADDRESS E-MAIL CONTRACTOR 33455 6th Ave S.,Unit 1-B spencer.j.fitch@lennar.com `Federal Way STAWA ZIP 98003 FAX WA STATE CONTRACTOR'S LICENSE I EXPIRATION DATE FEDERAL WAY IUSINESS LICENSE I CC LENNNANI893QG 11/ 7 /2019 NAME PRIMARY PHONE Spencer Fitch 253-590-2213 APPLICANT MAILING ADDRESS E-MAILspencer.j.fitch@lennar.com 33455 6th Ave S.,Unit 1-B STATE ZIP FAX Federal Way WA 98003 NAME PROJECT CONTACT Julie Fison 253)590 2213 (The individual to receive and MAILING ADDRESS E-MAIL respond to all correspondence 33455 6th Ave S.,Unit 1-B spencer.j.fitch@lennar.com concerning this application) `"ATM9eederal Way WA ZI98003 FAX PROJECT FINANCING N , Lennar Northwest Inc. ®—e IBRWRIMMEID-- When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE (RCW 19.17.095) 33455 6th Ave S.,Unit 1-B Federal Way,WA 98003 (253) 590-2215 I certify under penalty of perjury that I am the property owner or authorised agent of the property owner.I certify that to the best of my knowledge,the information submitted in support of this permit application is true and correct I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorised by the issuance of a permit.I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating • construction or environmental laws. r I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as apart of this application. SIGNATURE: Speitee't 3itc$ DATE 11/8/2018 PRINT NAME: Spencer Fitch Bulletin#100-February 22,2016 Page 1 of 2 k\Handouts\Permit Application • • • VALUE OF MECHANICAL WORK MECHANICAL PERMIT $ 10,000.00 Indicate Now many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain. AIR HANDLING UNITS 5 FANS 5 GAS PIPE OUTLETS • OTHER(Describe) AIR CONI)' $SER .qi . FIREPLACE INSERTS HOODS(Come,rdd) BOILERS; r �, FURNACES 1 HOT WATERJFAIVI46(O..)Tankless C)MPRESSORS 46 ' GAS LOG SETS REFRIGERATION SYST 1 DUCTING GAS PIPING WOODSTOVES PLUMBING PERMIT VALUE OF PLUMBING WORK • $ 20,000.00 Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain. 2 BATHTUBS(or Tub/Shower Combo) 5 LAVS(H.,,d si„k.) 3 TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe) DRAINS 1 SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS -1SINKS(Kitchen/Utility) WATER HEATERS(sketiq —2-- HOSE BIBBS SUMPS 1 WASHING MACHINES 16 TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS N/A Lakehaven Utilty District N/A $ EXISTING/PREVIOUS USE LOT SIZE(In Squere Pest) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? Vacant 175,111 ❑Yes I§ No D Yes of No • RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE BASEMENT ,µ _ FIRST FLOOR(or Mobile Home) 0 1645 1645 / 6 1 SCONP.FLOOR -0. ,1.611, x'619.' • COVERED ENTRY 0 C0 60 GARAGE if CARPORT ❑.,. 0 640 640 'O}1ER�(descilbe) •Rear.P41.--'ii-•` ---- _' 120 -_ ,20 - — LXISTIWOPIOroseo ... TOTAL Area Totals 4084 4084 : :-,..:-.._-,2.- -»*REVr.ao s oitti '.r-.; ,: ,-..;.:1.:',:::'::: :, ESTIMATED SELLING PRICE$ 350,000.00 I #OF BEDROOMS 4 _ COMMERCIAL—NEW/ADDITION Area in Construction ii of AREA DESCRIPTION Square Feet Occupancy Group(s) Type Stories Additional Information Nispr•Bu1LDING '`' , - -,..-'1' . ?.. . ,•1. - ADDITION - COMMERCIAL—REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area Occupancy Group(s) Construction Storiesl tion oAdditinal Information Square Feet AL BUiLDINO 3t TENANT AREA ONLY PROJECT AREAONLX • -., '. nil ,• ., '-'‘'• ..,.• - .. _, • Bulletin#100—February 22,2016 Page 2 of 2 k:\Handouts\Permit Application Ca 18 - 105338 ',ILE. ATER&SEWER DISTRICT 1111111111111111111 Lakehaven Water & Sewer District — Development Engineering Section 31623 - 1st Ave S * PO Box 4249 * Federal Way, WA 98063-4249 Telephone: 253-945-1581 or 253-945-1580 * Email: DE@Lakehaven.org This certificate is intended to provide the applicant, land use agencies &/or public health departments with information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole discretion, reserves the right to delay, or deny, sewer service based upon capacity 84/or supply limitations in Lakehaven's or Other Purveyor's system facilities. Proposed Land Use: ® Building Permit-SFR(56) 0 Building Permit-MFR 0 Building Permit-Other ❑ Subdivision 0 Short Subdivision 0 Binding Site Plan 0 Rezone 0 Boundary Line Adjustment ❑Other(specify/describe) Tax Parcel Number(s): TBD(oris. 3021049020. 3021049021.3021049058. 3021049082) Site Address: Multiple Ex. Bldg.Area to Remain: N/A sf New Bldg.Area Proposed: 3.500-4.500 sf Lakehaven GIS Grid: H-13 Applicant's Name: Lennar NW. Inc. SEWER SYSTEM INFORMATION 1. ® Sewer service can be provided by service connections to new 2". 3" or 6" diameter sewer mains that are approximately 5+/- to 150+/-feet from the plat lots and the sewer system has the capacity to serve the proposed land use. 2. 0 Sewer service for the site will require an improvement to Lakehaven's sanitary sewer system of: ❑ a. feet of "diameter sewer main or trunk to reach the site; and/or ❑ b. The construction of a sanitary sewer collection system on the site; and/or ❑ c. A major portion of Lakehaven's comprehensive wastewater system plan would need to be implemented and/or constructed; and/or ❑ d. Other(describe): 3. tEl a. The existing sewer system is in conformance with Lakehaven's Comprehensive Wastewater System Plan. ❑ b. The existing sewer system is not in conformance with Lakehaven's Comprehensive Wastewater System Plan and an Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits. 4. ® a. The proposed site land use is within the corporate limits of Lakehaven Water&Sewer District,or has been granted Boundary Review Board approval for extension of sewer service outside of Lakehaven's sewer service area. O b. Annexation or Boundary Review Board approval will be necessary to provide service. 5. Sewer service is subject to: ® a. Payment of connection charges(to be determined by Lakehaven); ® b. Proof or reservation of easement(s) as required by Lakehaven; ® c. Other: Sewer Service Connection Permit(1/lot) required. Private Grinder Pump Agreement(1/lot) reauired. Comments/special conditions: Associated Developer Extension Agreement protect(#6314010) must be accepted by Lakehaven, prior to activating service connections. I hereby certify that the above sewer system information is true. This certification shall be valid for one (1) year from the date of signature. Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR ` f 0a 3/5-7/0Signature: w�`* Date: Or RECEIVED 1O\/ 14 ''x13 Retreat Meadows swr.docx (Form Update 1/3/17) Page 1 of 2 C;11-1' CI- :cL';`F \_`v`:A✓ COMMUNITY DEVELOPMENT SW 356"S1 sus : ..�PnI 1-4! ir`rn�„.% 31 w% # # NI 1 -w wb, 1E ioit .q 4 :Z N 302104902 W. 5 s 3021049036 M t 9 A ire 10 r 56 3021049125 11 : 55 r 12 3021049118 54 53 52 3021049164 13 • I 14 1IT #*, SW 358TH ST 15 1 43 — • 46 47 3021049156 3021049121 16 17 42 51 B 41 ~- 50 ; 3 S 358TH P4 — to �,•• 40 49 R 4 3021049004 18 3 39 : t~ X H vi - M ww...M+_� .64 19 `, N - in a 38 35134 3021049126 20 N 3 , 3021049157 21 SW 359TH Pt ,{ taws ■r as r # 22 , . El 26 27 28 29 3p 3021049092 6,, c- 3021049013 'rarrw*sem rrrONIONS*r rwrrr wrr■ " ' eel hi MOTE: Lakehaven Water and Sewer Sewer C ertifcate of Availability District neither warrants nor guarantees Plat of Retreatment Meadows the accuracy of any facility information a 200 r.00 provided.Facility locations and conditions ' are subject tofietdverifbatten. Fed 3/5,/2018 B1A Retreat Meadows swr.docx(Form Update 1/3/17) Page 2 of 2 I a LAKE HAVEN UTILITY DISTRICT Hydraulic Model Fire Flow Estimate Request/Reporting Form Requested By: Date: Bert Ross 03/3/98 Hydrant Location: Off site of Illahee Jr HS 1/9Section: H-14 Intersection: Approx. s 360th and 1 Ave S Add. Description: KCSuL'1S t3I: DAIb: _ MOI/hL Kt/Di N4).: John. Bowma4 03/05/98 95LUDSFF.INP FF#57 Condition Pressure (psi) Flow (gpm) Static 100 0 Fire Flow 20 4800 NOTE: This fire flow rate will cause velocities in excess of 10 f/s within the water distribution system. A fire flow rate less than 2700 gpm will maintain flow velocities below 10 f/s. There is no guarantee that the Hydraulic Model results will represent actual system performance. Model results depict the theoretical performance of the system under high demand conditions. Field measurements should always be obtained for design purposes. ''- �`'\ 1. FINISHED GRADE TO SLOPE AWAY NOT LESS THAN 1:12 FOR A MINIMUM OF 6-FT OR TO PROPERTY LINE ADJACENT TO FOUNDATION AND SHALL START BELOW THE BOTTOMS OF ALL FOUNDATION VENTS. PROVIDE ADDITIONAL SOIL AS REQUIRED TO CREATE DRAINAGE AWAY FROM STRUCTURES ALONG PROPERTY LINE BETWEEN STRUCTURES. 2. ANY PORTIONS OF STRUCTURES WITH LESS THAN 10-FEET OF SEPARATION SHALL BE FIRE RATED. 3. INSTALL 8" OF TOPSOIL WITH 4" OF COMPOST WORKED INTO THE TOPSOIL. THIS WOULD NEED TO BE SPREAD OVER THE ENTIRE SITE, WHERE LAWN AND OTHER LANDSCAPING WOULD BE INSTALLED BY THE BUILDER OR FUTURE HOMEOWNER. 40.09' 44.58' 8.52' 22.31' SD STUB LOT 21 PLAT BOUNDARY i ; '. ���. N88 33'35 W 115.50 ROW� _ INFILTRATION TRENCH. _ —' I— �.__�__ :_-.i 1UE^N N BSBL (TYP.) Ii I TSS"., BUILDING EAVE, '— j FOOTPRINT PORCH L a INSTALL SILT 1 PROPOSED SEWER >� FENCE AS SHOWN it GRINDER PUMPS 3 , PATIO i>. LOT 22 SS LINE VALVE W > I PROPOSED SINGLE � FAMILY RESIDENCE �} z Z YARD DRAIN I l S Z ;. N EX I � t o CONTIOURS INSTALL SILT FENCE — AS SHOWN is N88'33'35"N z W— LOT I 40.09' WATER WATER SERVICE 22 24.41' Scale., �GHAVS Designed BMS 18215 72ND AVENUE SOUTH Om,m DBRIWS Horizontal ��� �Z KENT, WA 98032 1"=zB• (425)251-6222 Checked-9 S (425)251-8782 FAX Vertical 04, Mpmwd -gm—N/A .S+G` VA;1�®, �y CIVIL ENGINEERING, LAND PLANNING, Date V13 18 TrN� ENG0 SURVEYING, ENVIRONMENTAL SERVICES Re:R:\18000s\I8221\1ots\18221—Retreat Meadows—Lot.dwg Dote,mme:8/13/2018 11:06 AM 08MGGS For: LENNAR NORTHWEST INC. 33455 6TH AVENUE SOUTH, UNIT 1-13 FEDERAL WAY, WA 98003 (253) 590-2205 BUILDING SETBACKS: GARAGE 20' SIDE: 5' ROR: W LOT ADDRESS: 35913 2ND AVENUE SW FEDERAL WAY, WA LOT SIZE = 7,219 SF TOTAL IMPERVIOUS: 3,487 SF (48.3%) ROOF: 2,682 SF DRIVEWAY: 620 SF WALKWAY: 83 SF DECK: 102 SF Dp m TCE =INSTALL TEMP. CONST, ENTRM O 0 ; r m,, TSS =INSTALL TEMP. SOIL STOCKPILE Title: RETREAT MEADOWS RESIDENTIAL SITE PLAN SUBDIVISION LOT-22 PLAN No. 326 ` � m I m Job Nvm. A rb :E w 0 con o A w 1821Qc D�D0 Q n (D c PARCEL NO, TBD RECEI -D sn : � o' „ 1 of o N CITY OF FEDERALb'VAY n T.rli IMUNITY DEVELOPMENT