Loading...
20-102355-Site PlanINSTALLED BYSUPPLIED BYP.O REQ.1SECURITY ALARMN/AN/AN/A2AUDIO SYSTEMN/AN/AN/A3SHELVING ABOVE TOILETN/AN/AN/A4MANAGER'S DESKN/AN/AN/A5CASHWRAP & BACKWRAPN/AN/AN/A6DISPLAY FIXTURES FLOORN/AN/AN/A7GRAPHICS HOLDERSN/AN/AN/A8GRAPHICS INSERTSN/AN/AN/A9INTERIOR PARTITIONSNOLANDLORDLANDLORDSEE FINISH SCHEDULE10FLOORING MATERIALNOLANDLORDLANDLORDDIAMOND POLISHED CONCRETE FINISH12SHELVING @ MANAGER STATIONN/AN/AN/A13SAFEN/AN/AN/A14DOOR LOCKS (RE-KEY)NOTRUE SOURCETRUE SOURCEN.I.C. - COORDINATE WITH SKECHERS LOSS PREVENTION15DOOR ALARMNOLANDLORDLANDLORDDETEX, SEE PLAN FOR LOCATION16FIRE ALARM SYSTEMNOLANDLORDLANDLORDSEE PLAN FOR LOCATION17FIRE SPRINKLERSNOLANDLORDLANDLORDLANDLORD TO ADJUST AS NECESSARY* P.O. FOR THESE VENDORS WILL BE ISSUED BY SKECHERS LOSS PREVENTION DEPARTMENT - REFER TO PROJECT DIRECTORY.18FIRE EXTINGUISHERSNOLANDLORDLANDLORDLANDLORD TO COORDINATE INSTALLATION19HVAC ROOF TOP UNITNOLANDLORDLANDLORDLANDLORD TO PROVIDE WORKING SYSTEM. SEE HVAC DRAWINGS23LIGHT FIXTURESYESLANDLORDLANDLORDSEE LIGHTING SCHEDULE ON ELECTRICAL DRAWINGS22ELECTRICAL PANELSNOLANDLORDLANDLORDSEE ELECTRICAL DRAWINGS20HVAC DUCT / DIFFUSERNOLANDLORDLANDLORDLANDLORD TO MODIFY DUCTS AS NECESSARY. SEE HVAC DRAWINGS29LADDERS (SALES FLOOR)N/AN/AN/A24PLUMBING FIXTURESNOLANDLORDLANDLORDSEE PLUMBING DRAWINGS25RESTROOM ACCESSORIESNOLANDLORDLANDLORDMULTIPLE ITEMS REQURIED33SIGNAGE - EXTERIORN/AN/AN/A26STOCKROOM SHELVINGN/AN/AN/A27STOCKROOM EQUPMENTN/AN/AN/A21THERMOSTATS, SENSORSNOLANDLORDLANDLORDLANDLORD TO PROVIDE NEW THERMOSTAT & SENSORS. SEE HVAC DRAWINGS31TRASH SERVICEN/AN/AN/A30WATER DISPENSERN/AN/AN/A32SIGNAGE - INTERIORN/AN/AN/AREMARKSDESCRIPTIONNO.11VINYL BASE NOLANDLORDLANDLORD28LADDERS (STOCKROOM)N/AN/AN/AA-001COVER SHEETITEMDESCRIPTIONA-002GENERAL NOTESA-003GENERAL NOTESA-601ACCESSIBILITY NOTES & DETAILSA-101FLOOR PLANA-102REFLECTED CEILING PLAN1.CONTRACTOR SHALL COORDINATE THE DELIVERY (DATE, TIME) AND INSTALLATION OF ALL PRODUCTSSUPPLIED BY THE LISTED VENDORS, WHERE APPLICABLE.2.ALL VENDORS SHALL VERIFY DATE OF DELIVERY WITH CONTRACTOR UPON RECEIPT OF AN APPROVEDPURCHASE ORDER FROM SKECHERS, USA. SEE RESPONSIBILITY MATRIX.3.IT IS THE VENDORS RESPONSIBILITY TO ENSURE THAT THEIR MATERIALS OR FIXTURES ARE DELIVERED TOTHE JOBSITE UNDAMAGED. IN THE EVENT THAT DAMAGE OCCURS DURING SHIPPING, THE VENDOR SHALLIMMEDIATELY REPLACE ALL DAMAGED MATERIAL OR FIXTURES AT NO COST TO SKECHERS USA OR THECONTRACTOR. ALL CLAIMS MADE FOR DAMAGES DURING SHIPPING WILL BE MADE BY THE VENDORDIRECTLY WITH THE SHIPPING AGENT.4.UPON DELIVERY AND ACCEPTANCE OF VENDOR SUPPLIED PRODUCTS, IT IS THE CONTRACTORSRESPONSIBILITY TO MAINTAIN THE ITEM IN LIKE NEW CONDITION UNTIL TURN OVER OF STORE.5.UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL NOTIFY LENNY SMITH OF SKECHERS LOSSPREVENTION. SKECHERS LOSS PREVENTION WILL REPLACE EXISTING DOOR CYLINDERS WITH MEDICOCYLINDERS.6.THE SKECHERS USA VIDEO MUST BE OBTAINED ON SITE BY THE CONTRACTOR PRIOR TO TURN OVER DATE.CONTACT PROJECT MANAGER AT SKECHERS USA.7.PRIOR TO TURN OVER TO RETAIL, CONTRACTOR IS RESPONSIBLE FOR A COMPLETE CLEANING, INCLUDINGEXPOSED CEILING ELEMENTS AND JOISTS.8.THE GENERAL CONTRACTOR SHALL INVENTORY THE LIGHTING FIXTURES AND LAMPS UPON RECEIPT OFSHIPMENT FROM PREMIUM QUALITY LIGHTING. SHOULD ANY INACCURACIES OR DAMAGE TO SHIPMENTOCCUR, THE CONTRACTOR MUST CONTACT LIGHTING VENDOR. UPON ACCEPTANCE OF SHIPMENT, LIGHTINGFIXTURES ARE THE RESPONSIBILITY OF THE CONTRACTOR..9.FIREMASTER SHALL PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY THE GOVERNING FIRE AUTHORITY.CONTRACTOR SHALL COORDINATE INSTALLATION.10.IF ITEM SHOWN IN RESPONSIBILITY CHART IS SHOWN AS EXISTING, CONTRACTOR MUST MAKE SURE THATITEM IS IN WORKING AND LIKE NEW CONDITION.*CONTRACTOR TO CONTACT SKECHERS' PROJECT MANAGER BEFORE CONSTRUCTION BEGINS TO DETERMINEWHICH VENDORS WILL BE USED FROM ABOVE LIST.NOTE TO CONTRACTORS:ALL SUBCONTRACTORS SHALL RECEIVE A COMPLETE SET OF CONSTRUCTIONDOCUMENTS AND SPECIFICATIONS AND SHALL BE RESPONSIBLE FOR THEIRCOMPLETE SCOPE OF WORK REGARDLESS OF WHERE IN THE DOCUMENT SETTHE DESCRIPTION OF WORK APPEARS.CONTRACTORS VERIFICATION OF RESPONSIBILITES:CONTRACTOR SHALL REPORT ANY DISCREPANCIES, OMISSIONS ORINCONSISTENCIES ON THE DRAWINGS TO THE ARCHITECT FOR VERIFICATIONBEFORE STARTING CONSTRUCTION. OWNER AND ARCHITECT ARE NOTRESPONSIBLE FOR ANY ERRORS IN CONSTRUCTION WHERE SUCHDISCREPANCIES, OMISSIONS OR INCONSISTENCIES HAVE NOT BEEN PROPERLYREPORTED IN A TIMELY MANNER.SCOPE OF WORK:THE NEW WORK IS LIMITED TO INTERIOR (TENANT) IMPROVEMENTS TO AN EXISTING STRUCTURE CONSTRUCTEDFOR THE PURPOSE OF RETAIL SALES. NEW CONSTRUCTION WILL BE LIMITED TO ARCHITECTURAL FEATURES, NEWPARTITIONS, NEW FINISHES, INCLUDING PAINT, FLOOR COVERINGS. MEP WORK TO INCLUDE NEW LIGHTING, NEWHVAC UNITS W/ EXISTING &/OR NEW MECHANICAL DUCTWORK, NEW MOP SINK, NEW DRINKING FOUNTAIN AND NEWRESTROOMS. AS SUCH, NO MODIFICATION TO THE EXISTING, FUNDAMENTAL BUILDING SYSTEMS ARE ANTICIPATED. BUILDING CODES2015 INTERNATIONAL BUILDING CODE2015 INTERNATIONAL MECHANICAL CODE2015 INTERNATIONAL FIRE CODE2015 INTERNATIONAL ENERGY CONSERVATION CODE2015 WASHINGTON STATE ENERGY CODE2017 NATIONAL ELECTRICAL CODE2015 UNIFORM PLUMBING CODEBUILDING DEPARTMENT:33325 8TH AVE SFEDERAL WAY, WA 98003253-835-7001 EGRESS REQUIREMENTS:EGRESS WIDTH REQUIRED FRONT EXIT (SECTION 1005:1):0.2" x 52 OCCUPANTS = 10.4"EGRESS WIDTH PROVIDED FOR FRONT EXIT:72" EGRESS WIDTH REQUIRED REAR EXIT (SECTION 1005:1): 0.2" x 52 OCCUPANTS = 10.4" EGRESS WIDTH PROVIDED FOR REAR EXIT: 36"NUMBER OF EXITS REQUIRED (SECTION 1006):2NUMBER OF EXITS PROVIDED:2MAXIMUM TRAVEL DISTANCES (TABLE 1017.2):250'-0" ALLOWED (WITH SPRINKLERS)127'-7" ACTUALTOTAL BUILDING AREA: 7,160 S.F. (100%)SALES AREA: 6,103 S.F. (85%)STOCK/SUPPORT AREA: 1,057 S.F. (15%) CONSTRUCTION TYPE: TYPE 2B OCCUPANCY TYPE: M, MERCANTILEVICINITY PLAN1SCALE: NTSA-001COVER SHEETLOCATION PLAN5SCALE: NTSPROJECT & UTILITIES DIRECTORY2SCALE: NTSCODE REVIEW6SCALE: NTSSHEET INDEX7SCALE: NTSPROJECT VENDORS & NOTES3SCALE: NTSRESPONSIBILITY MATRIX4SCALE: NTSVENDOR NOTESA-201INTERIOR ELEVATIONSA-204HALLWAY & BACK OF HOUSE ELEVATIONSNOTE TO CONTRACTORS:ALL TENANT CONTRACTORS MUST PROVIDE LANDLORD WITH AN ORIGINAL SIGNEDCOPY OF THE CONSTRUCTION RULES (SEE FOLLOWING). THE TENANTCONTRACTOR OBTAINING THE TENANT IMPROVEMENT PERMIT IS THECONTRACTOR RESPONSIBLE FOR SUBMITTING ALL REQUIRED INFORMATION ANDCERTIFICATES OF INSURANCE TO THE LANDLORD.LOCKSMITHTRUE SOURCE17319 SAN PEDRO AVE.SAN ANTONIO, TX 78232PHONE: (800) 343-6835CELL: (562) 644-8555CONTACT: STACY RAMOSsramos@minercorp.comLIGHTINGPREMIUM QUALITY LIGHTING1871 TAPO ST.SIMI VALLEY, CA 93063PHONE: (800) 323-8107 x132FAX: (805) 579-8822CONTACT: CHRISTINA HAFEZIchafezi@pqllighting.comHVAC VENDORTRANE COMMERCIAL SYSTEMS3253 E. IMPERIAL HIGHWAYBREA, CA 92821PHONE: (714) 227-9366CONTACT: DEREK VAN RIPERderek.vanriper@trane.comSIGNAGEVISIBLE GRAPHICS9736 ETON AVE.CHATSWORTH, CA 91311PHONE: (818) 400-3682FAX: (818) 787-0415CONTACT: CHRISTINA GARCIAchristina@visiblegraphics.comA-202BACK OF HOUSE ELEVATIONS & DETAILSCELEBRATION CENTER32031 / 32041 PACIFIC HWY SOUTHFEDERAL WAY, WA 98003TENANT IMPROVEMENT FOR:A-602SCHEDULESSTAFFWAREHOUSE CONCEPT BUILDING OCCUPANT LOAD OCCUPANCY LOAD SF PER OCCUPANT OCCUPANTS SALES AREA: 6,103 S.F. / 60 101 STOCK/SUPPORT AREA: 1,057 S.F. / 300 3 TOTAL: 7,160 SF 104CMA-203EXTERIOR ELEVATIONSLANDLORD BUILD -OUTISSUE 06.17.20E-101POWER & SYSTEMS PLANE-102LIGHTING PLANE-501ELECTRICAL DETAILSM-101H.V.A.C. PLANM-601H.V.A.C. SCHEDULES AND DETAILSM-501H.V.A.C. DETAILSP-101PLUMBING PLANP-501PLUMBING SCHEDULES & DETAILSE-702ELECTRICAL SPECIFICATIONSM-701H.V.A.C. SPECIFICATIONSM-702H.V.A.C. SPECIFICATIONSP-701FIRE SUPPRESSION SPECIFICATIONSP-702PLUMBING SPECIFICATIONSMICHAEL'SSKECHERS ATCELEBRATION CENTERSKECHERS USA1240 ROSECRANS AVE, STE 400.MANHATTAN BEACH, CA 90266PHONE: (310) 318-3100FAX: (310) 937-1360CONSTRUCTION DEPT.CONTACT: KIM BENNETTPHONE: (310) 406-0606FAX: (310) 937-1360kbennett@skechers.comNEW STORE OPENING MANAGERCONTACT: FELICIA ETEFIAPHONE: (310) 318-3100 x1130FAX: (310) 374-6491feliciab@skechers.comLOSS PREVENTION DEPT.CONTACT: LENNY SMITHPHONE: (310) 318-3100 x4802FAX: (310) 374-6491lennys@skechers.comVISUAL MERCHANDISE DEPT.CONTACT: RICK DESIGANOPHONE: (310) 318-3100 x1820FAX: (310) 374-6492rickd@skechers.comARCHITECT:CORTLAND MORGAN ARCHITECT711 N. FIELDER ROADARLINGTON, TX 76012(817)635-5696MEP ENGINEER:SCHNACKEL ENGINEERS, INC.3035 SOUTH 72ND STREET OMAHA,NE 68124PHONE: (800) 581-0963 CONTACT: JOEL EMBURY jembury@schnackel.comLANDLORD: HARSCH INVESTMENT PROPERTIES1121 SW SALMON ST, STE 500PORTLAND, OR 97205PHONE: (503) 973-0205TENANT COORDINATOR: HARSCH INVESTMENT PROPERTIES1121 SW SALMON ST, STE 500PORTLAND, OR 97205PHONE: (503) 973-0205CONTACT: JAY FETHERSTONjayf@harsch.comCONTRACTOR:TBCPROJECT COORDINATOR:CONTACT: LUNCH BRENTPHONE: (310) 318-3100 x4633lunch.brent@skechers.com E-701ELECTRICAL SPECIFICATIONSE-601ELECTRICAL SCHEDULE & DETAILSS 320th St.S 324th St.20th Way SPacific Highway S13th Ave S11th Pl SROSSOLDNAVYRITE AIDTOTAL WINESKECHERSA-501DETAILSP-703PLUMBING SPECIFICATIONSP-704PLUMBING SPECIFICATIONS113606/12/2020