Loading...
23-100364 water&sewer availability 02.28.2023Lakehaven WATER & SEWER DISTRICT Lakehaven Water & Sewer District - Development Engineering Section 31623 - 1st Ave S * PO Box 4249 * Federal Way, WA 98063-4249 Email: DE@Lakehaven.org * Telephone: 253-945-1581 or 253-945-1580 This certificate is intended to provide the applicant, land use agencies &/or public health departments with information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole discretion, reserves the right to delay, or deny, sewer service based upon capacity &/or supply limitations in Lakehaven's or Other Purveyor's system facilities. Proposed Land Use: ❑ Building Permit-SFR () ❑ Building Permit-MFR () ❑ Building Permit -Other ❑ Subdivision () ® Short Subdivision (2) ❑ Binding Site Plan ❑ Boundary Line Adjustment ❑ Other (specify/describe) Parcel Number(s): 3021049155 Site Address: 365XX — 6th Ave SW LWSD GIs Grid: H-14 Ex. Bldg. Area to Remain: N/A sf New Bldg. Area Proposed: UNKNOWN sf WATER SYSTEM INFORMATION 1. ® Water service can be provided by service connection to existing 12" diameter water mains that are approximately 50+ - & 5+ - feet from the site. 2. ❑ Water service for the site will require an improvement to LWSD's water distribution system of: ❑ a. feet of " diameter water main to reach the site; and/or ❑ b. The construction of a water distribution system on the site; and/or ❑ c. A major portion of LWSD's comprehensive water system plan would need to be implemented and/or constructed; and/or ❑ d. Other (describe): 3. ® a. The existing water system is in conformance with LWSD's Comprehensive Water System Plan. ❑ b. The existing water system is not in conformance with LWSD's Comprehensive Water System Plan and an Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits. 4. ® a. The subject property is within the corporate limits of Lakehaven Water & Sewer District, or has been granted Boundary Review Board approval for extension of water service outside of LWSD's water service area. ❑ b. Annexation or Boundary Review Board approval will be necessary to provide service. S. Water service is subject to: ® a. Payment of connection charges (to be determined by LWSD); ❑ b. Proof or reservation of easement(s) as required by LWSD; ® c. Other: All water service connection stubs (all components except the service meter) must be installed & approved by LWSD, prior to subdivision approval & recording. LWSD Service Connection Applications required. Comments/special conditions: The nearest fire hydrant is approximately 65+ - feet from the Property (as marked on map on the back of this page). System hydraulic model results (FF #127, copy attached), at no less than 20 psi, indicate that LWSD's standard maximum allowable liquid velocity of 10 ft/s is exceeded at a fire flow rate above 3,400 GPM. This flow figure depicts the theoretical performance of the water distribution system under high demand conditions. Fire flow rates greater than this may be accommodated through water distribution system improvements, contact LWSD for additional information. 538 Pressure Zone Est. Meter Elevation(s)-GIS: 385+/- Est. Pressure Range at Meter(s) (psi): 57-66 I hereby certify that the above water system information is true. This certification shall be valid for one (1) year from the date of signature. Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR Signature: 3higa ffi#M 1C1 fe-signed) Date: 1126123 3021049155 wtr swr.docx (Form Update 1/20/22) of 4 Page 1 210494 3D210 % 3DZ 04DD 52 F-- 3D21049154 3D21049155 ram. Hyd r. s w ass ?v s 7- 3D210 1 ;y 3D21049041 3D210 MOTE: Lakehaven Water and Sewer District neither warrants nor guarantees the accuracy of any facility information provided. Facility lcoati onsand conditions are subject to fiel d verificatiarl Water C ertificate of Ava i la b i I i ty 4 Parcel 30211-049155 17 3 1r'26V 3 3021049155 wtr swr.docx (Form Update 1/20/22) of 4 Page 2 Lakehaven WATER & SEWER DISTRICT SEWER CERTIFICATE OF AVAILABILITY Lakehaven Water & Sewer District - Development Engineering Section 31623 - 1st Ave S * PO Box 4249 * Federal Way, WA 98063-4249 Email: DE@Lakehaven.org * Telephone: 253-945-1581 or 253-945-1580 This certificate is intended to provide the applicant, land use agencies &/or public health departments with information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole discretion, reserves the right to delay, or deny, sewer service based upon capacity &/or supply limitations in Lakehaven's or Other Purveyor's system facilities. Proposed Land Use: ❑ Building Permit-SFR () ❑ Building Permit-MFR () ❑ Building Permit -Other ❑ Subdivision () ® Short Subdivision (2) ❑ Binding Site Plan ❑ Boundary Line Adjustment ❑ Other (specify/describe) Parcel Number(s): 3021049155 Site Address: 365XX — 6th Ave SW LWSD GIs Grid: H-14 Ex. Bldg. Area to Remain: N/A sf New Bldg. Area Proposed: UNKNOWN sf SEWER SYSTEM INFORMATION 1. ® Sewer service can be provided by service connection to new 4" or 2" diameter low-pressure sewer mains that are approximately 15+ - feet from the site and the sewer system has the capacity to serve the proposed land use. 2. ❑ Sewer service for the site will require an improvement to LWSD's sanitary sewer system of: ❑ a. feet of " diameter sewer main or trunk to reach the site; and/or ❑ b. The construction of a sanitary sewer collection system on the site; and/or ❑ c. A major portion of LWSD's comprehensive wastewater system plan would need to be implemented and/or constructed; and/or ❑ d. Other (describe): 3. ® a. The existing sewer system is in conformance with LWSD's Comprehensive Wastewater System Plan. ❑ b. The existing sewer system is not in conformance with LWSD's Comprehensive Wastewater System Plan and an Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits. 4. ® a. The proposed site land use is within the corporate limits of Lakehaven Water & Sewer District, or has been granted Boundary Review Board approval for extension of sewer service outside of LWSD's sewer service area. ❑ b. Annexation or Boundary Review Board approval will be necessary to provide service. S. Sewer service is subject to: ® a. Payment of connection charges (to be determined by LWSD); ❑ b. Proof or reservation of easement(s) as required by LWSD; ® c. Other: All sewer service connection stubs (main -to -lot) must be installed & approved by LWSD, prior to subdivision approval & recording. LWSD Service Connection application required, subiect to completion of adiacent LWSD DE Agreement project(s). Private Grinder Pump Agreements required. Comments/special conditions: I hereby certify that the above sewer system information is true. This certification shall be valid for one (1) year from the date of signature. Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR Signature: Bs6 = ffi#U 6[L fe-signed) Date: 1126123 3021049155 wtr swr.docx (Form Update 1/20/22) of 4 Page 3 0 4901 3021049150 30210480 55 i i i i 3021049U 52 i i i i i i LI 3021049155 i i y i i i s ■ J 2 7 3021049041 a� i NOTE: Lakehaven Water and Sewer District neither warrants nor guarantees the accuracy of any facility information provided. Facility locations and conditions 3rE subject to field verification_ Sewer C ertificate of Avail abil ity Parcel3021049155 1130 3021049154 1f2EJ23 3021049155 wtr swr.docx (Form Update 1/20/22) of 4 Page 4 LAKEHAVEN UTILITY DISTRICT Hydraulic Model Fire Flow Estimate Request/Reporting Form Requested By: Kathy Brown Date: 08/17/99 Location to be Modeled: Lakebaven'/a Section Grid: H-14 Intersection: SW 361st St & 6' Ave SW - Approx. Add. Description: See attached map Pressure Zone: Results By: John Bowman Date: 08/19/99 Model Run No.: 95 LUDSFF.INP FF#127 Condition Pressure (psi) Flow (gpm) Static 71 0 Fire Flow 20 3500 NOTES: Lakehaven's adopted level of service goals for fire flow rates are 1000 gpm within single family residential areas (including duplexes) and 2500 gpm for multi -family, commercial, industrial areas. Model results depict the theoretical performance of the water system under high demand conditions and are not guaranteed to represent actual system performance. A design professional should be consulted for site specific design purposes. The calculated fire flow capacity in the above table is based on a currently available residual system pressure of 20 psi at the location modeled. The model indicates that Lakehaven's standard maximum allowable velocity of 10 ft/s is exceeded at a fire flow rate above 3400 gpm. Fire flow capacities greater than 2500 gpm may be accommodated through water system improvements. Form Rev. 5/30/08