23-101488_Geotech_Letter_3-22-2315365 N.E. 90th Street, Suite 100 • Redmond, WA 98052 • (425) 449-4704 • FAX (425) 449-4711 Earth Solutions NW LLC Geotechnical Engineering, Construction Observation/Testing and Environmental Services June 3, 2022 ES-8485 American Pride Lending, LLC P.O. Box 1226 Kent, Washington 98035 Attention: Mr. Sikander Sekhon Subject: Geotechnical Evaluation Proposed Short Plat 2240 South 288th Street Federal Way, Washington Reference: H.H. Waldron Geologic Map of the Poverty Bay Quadrangle, 1961 United States Department of Agriculture (USDA) Natural Resources Conservation Service Online Web Soil Survey (WSS) Resource Federal Way Revised Code (FWRC) Chapter 19.145 – Environmentally Critical Areas King County Flood Control District Liquefaction Susceptibility (Map 11-5), dated May 2010 King County Department of Natural Resources and Parks 2021 Surface Water Design Manual, dated July 23, 2021 Dear Mr. Sekhon: As requested, Earth Solutions NW, LLC (ESNW) has prepared this geotechnical evaluation for the subject site. We performed our work in general accordance with the scope of services outlined in our proposal dated March 10, 2022, which was authorized by you on March 29, 2022. A summary of the field investigation and pertinent geotechnical design recommendations and conclusions are provided in this letter. American Pride Lending, LLC ES-8485 June 3, 2022 Page 2 Earth Solutions NW, LLC Project & Site Description The subject site is located directly northwest of the intersection between South 288th Street and 23rd Place South in Federal Way, Washington. The approximate site location is illustrated on the attached Vicinity Map (Plate 1). The site is comprised of one tax parcel (King County Parcel No. 332204-9023), totaling about 0.9 acres. The subject site is currently unoccupied. Based on review of historical aerial photographs available on the King County iMap, the site was previously developed with a single-family residence which appears to have been removed sometime between 2002 and 2005; subsequent to removal of the structure, the site appears to have been cleared and somewhat regraded sometime between 2007 and 2009. Site topography gently descends to the southwest. Total elevation change across the subject site is approximately 15 feet. Vegetation consists of field grass and a few mature trees. Based on conceptual plans communicated to us, we four new single-family homes will be constructed on the subject site. Grading plans were not available at the time of this evaluation; however, based on the existing site topography, we anticipate grading will consist of cuts and fills of less than about 5 to 10 feet. Subsurface An ESNW representative observed, logged, and sampled three test pits on April 14, 2022. The test pits were excavated within accessible areas of the site using a mini trackhoe and operator retained by ESNW. The test pits were completed to assess soil conditions, classify site soils, and characterize groundwater conditions within the proposed development area. The approximate locations of the test pits are depicted on the attached Plate 2 (Test Pit Location Plan). Please refer to the attached test pit logs for a more detailed description of subsurface conditions. Representative soil samples collected at the test pit locations were analyzed in general accordance with both Unified Soil Classification System (USCS) and USDA methods and procedures. Topsoil Topsoil, was generally encountered within the upper 6 to 12 inches below the existing ground surface (bgs). The topsoil was characterized by its dark brown color, the presence of fine organic material, and root intrusions extending up to three feet bgs. Fill Fill was encountered at all test pit locations during our subsurface exploration extending to a depth of approximately two feet bgs. The fill is characterized as silty sand with gravel in a loose and moist condition. Based on the existing site conditions and review of historical aerial photographs, we anticipate that fill will be encountered across the majority of the buildable site area. American Pride Lending, LLC ES-8485 June 3, 2022 Page 3 Earth Solutions NW, LLC Native Soil Underlying topsoil and fill, native soil was encountered as medium dense to very dense silty gravel with varying amounts of sand (USCS: GW-GM and GM). Native soil relative density generally increased with depth and becomes weakly cemented beginning at depths of roughly three to four feet bgs. Native soil was generally encountered in a moist to wet condition. Geologic Setting The referenced geologic map identifies ground moraine deposits (Qgt) across the subject property and surrounding area. As reported on the geologic map resource, ground moraine deposits are comprised of compact, unoxidized glacial till. The material is typically very dense and weakly cemented resulting from glacial overburden. Glacial till is commonly termed “hardpan” in western Washington. Distinct features of the material are compactness, ability to maintain near-vertical slopes, very low permeability, and a heterogenous internal structure resembling a low-strength concrete. Based on our field observations, native soil likely to be exposed during grading activities will be consistent with glacial till deposits. The referenced WSS resource identifies arents of Alderwood material (Map Unit: AmC) as the primary soil unit underlying the subject site. Soils of the arents of Alderwood series are associated with glacial till ridge and hill landforms, which were modified by human grading activity. The native soil observed is generally consistent with Alderwood series soil. Groundwater Groundwater was encountered at test pit locations TP-1 and TP-2 during the April 2022 subsurface exploration. The light groundwater seepage was observed at depths of about four and five bgs. Additionally, light iron oxide staining was observed at all test pit locations at a depth of about three feet bgs, which is indicative of seasonal groundwater seepage. Groundwater seepage rates and elevations fluctuate depending on many factors, including precipitation duration and intensity, the time of year, and soil conditions. In general, groundwater flow rates are higher during the winter, spring, and early summer months. Critical Areas Review ESNW reviewed FWRC Chapter 19.145 to determine if geologically relevant critical areas recognized by Federal Way (including erosion, landslide, and seismic hazard areas) exist on or near the subject site. Our review indicates that these critical areas have not been mapped on site or in proximity to the site. Based on our field observations, it is our opinion the site is correctly mapped outside of the geologically relevant critical areas listed herein. Discussion & Recommendations The following sections provide discussion and recommendations to aid with the design and construction of the proposed single-family residences and related improvements. American Pride Lending, LLC ES-8485 June 3, 2022 Page 4 Earth Solutions NW, LLC In-Situ and Imported Soil Most of the in-situ soils encountered at the subject site have a moderate to high sensitivity to moisture and were generally in a moist to wet condition at the time of exploration. Soils anticipated to be exposed on site will degrade if exposed to wet weather and construction traffic. Compaction of the soils to the levels necessary for use as structural fill may be difficult or impossible during wet weather conditions. Soils encountered during site excavations that are excessively over the optimum moisture content will likely require aeration or treatment prior to placement and compaction. Conversely, soils that are substantially below the optimum moisture content will require moisture conditioning through the addition of water prior to use as structural fill. An ESNW representative should determine the suitability of in-situ soils for use as structural fill at the time of construction. Imported soil intended for use as structural fill should consist of a well-graded, granular soil with a moisture content that is at (or slightly above) the optimum level. During wet weather conditions, imported soil intended for use as structural fill should consist of a well-graded, granular soil with a fines content of 5 percent or less (where the fines content is defined as the percent passing the Number 200 sieve, based on the minus three-quarter-inch fraction). Structural Fill Structural fill is defined as compacted soil in foundation, slab-on-grade, driveway, retaining wall, and utility trench areas. Soils placed in structural areas should be placed in maximum 12-inch loose lifts and compacted to a relative compaction of 95 percent, based on the laboratory maximum dry density as determined by the Modified Proctor Method (ASTM D1557). Fill should be placed on a firm and level surface. ESNW should be consulted during early grading activities to provide additional recommendations regarding structural fill placement, where necessary. Excavations and Slopes Based on the soil conditions observed at the test pit locations, the following allowable temporary slope inclinations, as a function of horizontal to vertical (H:V) inclination, are recommended. The applicable Federal Occupation Safety and Health Administration (OSHA) and Washington Industrial Safety and Health Act (WISHA) soil classifications are also provided: Loose soil 1.5H:1V (Type C) Areas exposing groundwater seepage 1.5H:1V (Type C)  Medium dense soil 1H:1V (Type B) Dense to very dense “hardpan” native soil 0.75H:1V (Type A) American Pride Lending, LLC ES-8485 June 3, 2022 Page 5 Earth Solutions NW, LLC ESNW can evaluate the feasibility of utilizing steeper temporary slopes at the time of construction. In any case, an ESNW representative should observe temporary slopes to confirm inclinations are suitable for the exposed soil conditions and to provide additional excavation and slope stability recommendations, as necessary. If the recommended temporary slope inclinations cannot be achieved, temporary shoring may be necessary to support excavations. Permanent slopes should be graded to 2H:1V (or flatter) and planted with vegetation to enhance stability and minimize erosion potential. Permanent slopes should be observed by ESNW prior to vegetation and landscaping. Foundations In our opinion, the proposed single-family residential structures can be constructed on a conventional continuous and spread footing foundation bearing on competent native soil, recompacted native soil, or new structural fill placed directly on competent native soil. Competent native soil suitable for support of foundations will likely be encountered beginning at depths of about two to three feet bgs. Where loose or unsuitable soil conditions are exposed at foundation subgrade elevations, compaction of the soil to the specifications of structural fill or overexcavation and replacement with suitable structural fill will be necessary. Provided the foundations will be supported as described above, the following parameters may be used for design: Allowable soil bearing capacity 2,500 psf  Passive earth pressure 300 pcf  Coefficient of friction 0.40 The passive earth pressure value provided above assumes the foundations will be backfilled with structural fill. A factor-of-safety of 1.5 has been applied to the passive earth pressure and coefficient of friction values provided in this section. For short-term wind and seismic loading, a one-third increase in the allowable soil bearing capacity may be assumed. With structural loading as expected, total settlement of about one inch and differential settlement of approximately one- half inch is anticipated. Most of the anticipated settlement should occur during construction, as dead loads are applied. Slab-on-Grade Floors Slab-on-grade floors should be supported on a suitable capillary break material underlain by a compacted and competent subgrade. Structural fill in slab-on-grade areas should be compacted to a minimum relative compaction of 95 percent. Unstable or yielding areas of the subgrade should be recompacted, or overexcavated and replaced with suitable structural fill, prior to slab construction. American Pride Lending, LLC ES-8485 June 3, 2022 Page 6 Earth Solutions NW, LLC Slab-on-grade areas should be provided with a minimum four-inch-thick capillary break. Capillary break soils should consist of a granular, free-draining coarse sand and gravel soil that contains less than 5 percent fines (percent passing the Number 200 sieve, based on the minus three- quarter-inch fraction). To facilitate grading of the slab subgrade, the maximum aggregate size of the capillary break material should generally be one-and-one-quarter inch. In areas where slab moisture is undesirable, installation of a vapor barrier placed below the slab should be considered. If a vapor barrier will be utilized, it should consist of a material specifically designed for that use and should be installed in accordance with the specifications of the manufacturer. Seismic Design The 2018 International Building Code (2018 IBC) recognizes the most recent edition of the Minimum Design Loads for Buildings and Other Structures manual (ASCE 7-16) for seismic design, specifically with respect to earthquake loads. Based on the soil conditions encountered at the test pit locations, the parameters and values provided below are recommended for seismic design per the 2018 IBC. Parameter Value Site Class C* Mapped short period spectral response acceleration, SS (g) 1.336 Mapped 1-second period spectral response acceleration, S1 (g) 0.458 Short period site coefficient, Fa 1.200 Long period site coefficient, Fv 1.500 Adjusted short period spectral response acceleration, SMS (g) 1.603 Adjusted 1-second period spectral response acceleration, SM1 (g) 0.687 Design short period spectral response acceleration, SDS (g) 1.069 Design 1-second period spectral response acceleration, SD1 (g) 0.458 *Assumes very dense soil conditions, encountered to a maximum depth of 10 feet bgs during the March 2022 field exploration, remain very dense to at least 100 feet bgs. Based on our experience with the project geologic setting (glacial till) across the Puget Sound region, soil conditions are likely consistent with this assumption. Liquefaction is a phenomenon where saturated and loose cohesionless soil suddenly loses internal strength and behaves as a fluid. This behavior is in response to increased pore water pressures resulting from an earthquake or another intense ground shaking. In our opinion, site susceptibility to liquefaction can be considered negligible. The composition and relatively dense characteristics of the native soil were the primary bases for this opinion. American Pride Lending, LLC ES-8485 June 3, 2022 Page 7 Earth Solutions NW, LLC Retaining Walls Retaining walls must be designed to resist earth pressures and applicable surcharge loads. The following parameters may be used for design: Active earth pressure (unrestrained condition) 35 pcf (equivalent fluid) At-rest earth pressure (restrained condition) 55 pcf Traffic surcharge* (passenger vehicles)70 psf (rectangular distribution) Passive earth pressure 300 pcf (equivalent fluid)  Coefficient of friction 0.40  Seismic surcharge 8H psf** * Where applicable. ** Where H equals the retained height (in feet). Retaining walls should be backfilled with free-draining material that extends along the height of the wall and a distance of at least 18 inches behind the wall; a typical retaining wall drainage detail (Plate 3) is attached to this letter. The upper 12 inches of the wall backfill may consist of a less permeable soil, if desired. A sheet drain may be considered in lieu of free-draining backfill. A perforated drainpipe should be placed along the base of the wall and connected to an approved discharge location. If drainage is not provided, hydrostatic pressures should be included in the wall design. Drainage Groundwater was encountered at test pit locations TP-1 and TP-2 at depths of about four feet and five feet, respectively. Based on the encountered soil types, we anticipate groundwater seepage to be common during subsurface excavations on the subject property, particularly during utility excavations. Temporary measures to control groundwater seepage and surface water runoff during construction will likely involve passive elements such as interceptor trenches and sumps, as necessary. Surface grades must be designed to direct water away from structures and slopes. The grade adjacent to the buildings should be sloped away from the buildings at a gradient of at least 2 percent for a minimum horizontal distance of either 10 feet or as setbacks allow. In our opinion, perimeter footing drains should be installed at or below the invert of the building footings. A typical footing drain detail is provided on Plate 4 of this report. If footing drains are not installed, we recommend backfilling footings with a relatively impermeable soil. American Pride Lending, LLC ES-8485 June 3, 2022 Page 8 Earth Solutions NW, LLC Preliminary Infiltration Evaluation We understand on-site stormwater infiltration is being considered for the proposed project. Based on existing grades, we would anticipate project grading to include cuts of about 5 to 10 feet, which would expose weakly cemented, low permeability soil. Based on our subsurface observations of glacial till deposits and indications of seasonal groundwater seepage (iron oxide staining) as shallow as about three feet bgs, we do not recommend incorporating infiltration into the overall stormwater design. However, ESNW can further evaluate the potential for limited infiltration BMPs based on proposed site design, if requested. Limitations This letter has been prepared for the exclusive use of American Pride Lending, LLC and their representatives. No warranty, express or implied, is made. The recommendations and conclusions provided in this letter are professional opinions consistent with the level of care and skill that is typical of other members in the profession currently practicing under similar conditions in this area. If the design assumptions outlined in this letter either change or are incorrect, or if construction conditions differ from those encountered during our fieldwork, ESNW should be contacted to review the recommendations and conclusions provided in this letter. Additional Services ESNW should have an opportunity to review the final design with respect to the geotechnical recommendations provided in this letter. ESNW should also be retained to provide testing and consultation services during construction. American Pride Lending, LLC ES-8485 June 3, 2022 Page 9 Earth Solutions NW, LLC We trust this letter meets your current needs. Should you have any questions regarding the content herein, or require additional information, please call. Sincerely, EARTH SOLUTIONS NW, LLC Samuel E. Suruda, L.G. Henry T. Wright, P.E. Senior Staff Geologist Associate Principal Engineer Attachments: Plate 1 – Vicinity Map Plate 2 – Test Pit Location Plan Plate 3 – Retaining Wall Drainage Detail Plate 4 – Footing Drain Detail Test Pit Logs Grain Size Distribution cc: Encompass Engineering & Surveying Attention: Ms. Heather Tatro (Email only) 06/03/2022 Drwn.CAM Checked SES Date May 2022 Date 05/31/2022 Proj.No.8485 Plate 1 Geotechnical Engineering,Construction Observation/Testing and Environmental Services Earth Solutions NWLLCEarthSolutionsNWLLC EarthSolutions NW LLC Vicinity Map S.288th Street Short Plat Federal Way,Washington Reference: King County,Washington OpenStreetMap.org NORTH NOTE:This plate may contain areas of color.ESNW cannot be responsible for any subsequent misinterpretation of the information resulting from black &white reproductions of this plate. Federal Way SITE Drwn.CAM Checked SES Date May 2022 Date 05/31/2022 Proj.No.8485 Plate 2 Geotechnical Engineering,Construction Observation/Testing and Environmental Services Earth Solutions NWLLCEarthSolutionsNWLLC EarthSolutions NW LLC TP-1TP-2 TP-3 s.288th street Test Pit Location Plan S.288th Street Short Plat Federal Way,Washington NOTE:This plate may contain areas of color.ESNW cannot be responsible for any subsequent misinterpretation of the information resulting from black &white reproductions of this plate. NOTE:The graphics shown on this plate are not intended for design purposes or precise scale measurements,but only to illustrate the approximate test locations relative to the approximate locations of existing and /or proposed site features.The information illustrated is largely based on data provided by the client at the time of our study.ESNW cannot be responsible for subsequent design changes or interpretation of the data by others. LEGEND Approximate Location of ESNW Test Pit,Proj.No. ES-8485,April 2022 Subject Site Existing Building TP-1 NOT -TO -SCALE NORTH Geotechnical Engineering,Construction Observation/Testing and Environmental Services Drwn.CAM Checked SES Date May 2022 Date 05/31/2022 Proj.No.8485 Plate 3 Earth Solutions NWLLCEarthSolutionsNWLLC EarthSolutions NW LLC NOTES: Free-draining Backfill should consist of soil having less than 5 percent fines. Percent passing No.4 sieve should be 25 to 75 percent. Sheet Drain may be feasible in lieu of Free-draining Backfill,per ESNW recommendations. Drain Pipe should consist of perforated, rigid PVC Pipe surrounded with 1-inch Drain Rock. LEGEND: Free-draining Structural Backfill 1-inch Drain Rock 18"Min. Structural Fill Perforated Rigid Drain Pipe (Surround in Drain Rock) SCHEMATIC ONLY -NOT TO SCALE NOT A CONSTRUCTION DRAW ING Retaining Wall Drainage Detail S.288th Street Short Plat Federal Way,Washington Geotechnical Engineering,Construction Observation/Testing and Environmental Services Drwn.CAM Checked SES Date May 2022 Date 05/31/2022 Proj.No.8485 Plate 4 Earth Solutions NWLLCEarthSolutionsNWLLC EarthSolutions NW LLC Slope Perforated Rigid Drain Pipe (Surround in Drain Rock) 18"Min. NOTES: Do NOT tie roof downspouts to Footing Drain. Surface Seal to consist of 12"of less permeable,suitable soil.Slope away from building. LEGEND: Surface Seal:native soil or other low-permeability material. 1-inch Drain Rock SCHEMATIC ONLY -NOT TO SCALE NOT A CONSTRUCTION DRAW ING Footing Drain Detail S.288th Street Short Plat Federal Way,Washington GRAVEL AND GRAVELLY SOILS CLAYEY GRAVELS, GRAVEL - SAND - CLAY MIXTURES WELL-GRADED SANDS, GRAVELLY SANDS, LITTLE OR NO FINES POORLY-GRADED SANDS, GRAVELLY SAND, LITTLE OR NO FINES SILTY SANDS, SAND - SILT MIXTURES CLAYEY SANDS, SAND - CLAY MIXTURES INORGANIC SILTS AND VERY FINE SANDS, ROCK FLOUR, SILTY OR CLAYEY FINE SANDS OR CLAYEY SILTS WITH SLIGHT PLASTICITY INORGANIC CLAYS OF LOW TO MEDIUM PLASTICITY, GRAVELLY CLAYS, SANDY CLAYS, SILTY CLAYS, LEAN CLAYS ORGANIC SILTS AND ORGANIC SILTY CLAYS OF LOW PLASTICITY INORGANIC SILTS, MICACEOUS OR DIATOMACEOUS FINE SAND OR SILTY SOILS INORGANIC CLAYS OF HIGH PLASTICITY SILTS AND CLAYS MORE THAN 50% OF MATERIAL IS LARGER THAN NO. 200 SIEVE SIZE MORE THAN 50% OF MATERIAL IS SMALLER THAN NO. 200 SIEVE SIZE MORE THAN 50% OF COARSE FRACTION PASSING ON NO. 4 SIEVE MORE THAN 50% OF COARSE FRACTION RETAINED ON NO. 4 SIEVE SOIL CLASSIFICATION CHART (APPRECIABLE AMOUNT OF FINES) (APPRECIABLE AMOUNT OF FINES) (LITTLE OR NO FINES) FINE GRAINED SOILS SAND AND SANDY SOILS SILTS AND CLAYS ORGANIC CLAYS OF MEDIUM TO HIGH PLASTICITY, ORGANIC SILTS PEAT, HUMUS, SWAMP SOILS WITH HIGH ORGANIC CONTENTS LETTERGRAPH SYMBOLSMAJOR DIVISIONS COARSE GRAINED SOILS TYPICAL DESCRIPTIONS WELL-GRADED GRAVELS, GRAVEL - SAND MIXTURES, LITTLE OR NO FINES POORLY-GRADED GRAVELS, GRAVEL - SAND MIXTURES, LITTLE OR NO FINES SILTY GRAVELS, GRAVEL - SAND - SILT MIXTURES CLEAN GRAVELS GRAVELS WITH FINES CLEAN SANDS (LITTLE OR NO FINES) SANDS WITH FINES LIQUID LIMIT LESS THAN 50 LIQUID LIMIT GREATER THAN 50 HIGHLY ORGANIC SOILS DUAL SYMBOLS are used to indicate borderline soil classifications. The discussion in the text of this report is necessary for a proper understanding of the nature of the material presented in the attached logs. GW GP GM GC SW SP SM SC ML CL OL MH CH OH PT Earth Solutions NW LLC MC = 20.2% MC = 9.4% Fines = 11.7% MC = 6.2% MC = 6.0% TPSL SM GW- GM Dark brown TOPSOIL, trace roots to 3' (Fill) Brown silty SAND with gravel, loose to medium dense, moist (Fill) Brown well-graded GRAVEL with silt and sand, medium dense, wet -becomes gray, dense, moist, weakly cemented [USDA Classification: extremely gravelly coarse sandy LOAM] -light iron oxide staining -light groundwater seepage -becomes dense to very dense Test pit terminated at 9.5 feet below existing grade. Groundwater seepage encountered at 4.0 feet during excavation. No caving observed. 1.0 2.0 9.5SAMPLE TYPENUMBERDEPTH(ft)0.0 2.5 5.0 7.5 PAGE 1 OF 1 TEST PIT NUMBER TP-1 NOTES Depth of Topsoil & Sod 8-12": brambles LOGGED BY KTK EXCAVATION METHOD EXCAVATION CONTRACTOR NW Excavating CHECKED BY HTW DATE STARTED 4/14/22 COMPLETED 4/14/22 GROUND WATER LEVEL: AT TIME OF EXCAVATION GROUND ELEVATION LATITUDE 47.34381 LONGITUDE -122.30325 PROJECT NUMBER ES-8485 PROJECT NAME S. 288th Street Short Plat GENERAL BH / TP / WELL - 8485.GPJ - GRAPHICS TEMPLATE WITH LAT AND LONG.GDT - 5/31/22Earth Solutions NW, LLC 15365 N.E. 90th Street, Suite 100 Redmond, Washington 98052 Telephone: 425-449-4704 Fax: 425-449-4711 TESTS U.S.C.S.MATERIAL DESCRIPTION GRAPHICLOG MC = 13.0% MC = 19.7% MC = 9.3% MC = 8.5% Fines = 35.5% TPSL SM GM Dark brown TOPSOIL (Fill) Brown silty SAND with gravel, loose, moist (Fill) Brown silty GRAVEL with sand, medium dense, wet -becomes moist -becomes gray, dense, weakly cemented, light iron oxide staining -becomes dense to very dense -light groundwater seepage [USDA Classification: gravelly LOAM] Test pit terminated at 10.0 feet below existing grade. Groundwater seepage encountered at 5.0 feet during excavation. No caving observed. 1.0 2.0 10.0SAMPLE TYPENUMBERDEPTH(ft)0.0 2.5 5.0 7.5 10.0 PAGE 1 OF 1 TEST PIT NUMBER TP-2 NOTES Depth of Topsoil & Sod 8-12": grass LOGGED BY KTK EXCAVATION METHOD EXCAVATION CONTRACTOR NW Excavating CHECKED BY HTW DATE STARTED 4/14/22 COMPLETED 4/14/22 GROUND WATER LEVEL: AT TIME OF EXCAVATION GROUND ELEVATION LATITUDE 47.34381 LONGITUDE -122.30368 PROJECT NUMBER ES-8485 PROJECT NAME S. 288th Street Short Plat GENERAL BH / TP / WELL - 8485.GPJ - GRAPHICS TEMPLATE WITH LAT AND LONG.GDT - 5/31/22Earth Solutions NW, LLC 15365 N.E. 90th Street, Suite 100 Redmond, Washington 98052 Telephone: 425-449-4704 Fax: 425-449-4711 TESTS U.S.C.S.MATERIAL DESCRIPTION GRAPHICLOG MC = 12.1% MC = 10.8% Fines = 22.9% MC = 9.2% MC = 8.2% TPSL SM GM Dark brown TOPSOIL (Fill) Brown silty SAND with gravel, loose, moist (Fill) Brown silty GRAVEL with sand, medium dense, moist -light iron oxide staining [USDA Classification: very gravelly sandy LOAM] -becomes gray, dense, weakly cemented -becomes dense to very dense Test pit terminated at 10.0 feet below existing grade. No groundwater encountered during excavation. No caving observed. 0.5 2.0 10.0SAMPLE TYPENUMBERDEPTH(ft)0.0 2.5 5.0 7.5 10.0 PAGE 1 OF 1 TEST PIT NUMBER TP-3 NOTES Depth of Topsoil & Sod 6": grass LOGGED BY KTK EXCAVATION METHOD EXCAVATION CONTRACTOR NW Excavating CHECKED BY HTW DATE STARTED 4/14/22 COMPLETED 4/14/22 GROUND WATER LEVEL: AT TIME OF EXCAVATION GROUND ELEVATION LATITUDE 47.34368 LONGITUDE -122.30407 PROJECT NUMBER ES-8485 PROJECT NAME S. 288th Street Short Plat GENERAL BH / TP / WELL - 8485.GPJ - GRAPHICS TEMPLATE WITH LAT AND LONG.GDT - 5/31/22Earth Solutions NW, LLC 15365 N.E. 90th Street, Suite 100 Redmond, Washington 98052 Telephone: 425-449-4704 Fax: 425-449-4711 TESTS U.S.C.S.MATERIAL DESCRIPTION GRAPHICLOG 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 0.0010.010.1110100 3 D100 140 Specimen Identification 1 fine 6 HYDROMETER 304 11.7 35.5 22.9 101/2 COBBLES Specimen Identification 4 coarse 20 401.5 8 14 USDA: Brown Extremely Gravelly Coarse Sandy Loam. USCS: GW-GM with Sand. USDA: Gray Gravelly Loam. USCS: SM with Gravel. USDA: Brown Very Gravelly Sandy Loam. USCS: GM with Sand. 6 60 PERCENT FINER BY WEIGHTD10 1.032 0.171 17.862 0.551 3.915 GRAIN SIZE DISTRIBUTION 100 335.22 LL TP-01 TP-02 TP-03 3/4 U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS GRAVEL SAND 75 37.5 37.5 %Silt 1.12 TP-01 TP-02 TP-03 2 2003 Cc CuClassification %Clay 16 PID60 D30 coarse SILT OR CLAYfinemedium GRAIN SIZE IN MILLIMETERS 3/8 50 3.0ft. 10.0ft. 3.5ft. 3.00ft. 10.00ft. 3.50ft. PL PROJECT NUMBER ES-8485 PROJECT NAME S. 288th Street Short Plat GRAIN SIZE USDA ES-8485 S. 288TH STREET SHORT PLAT.GPJ GINT US LAB.GDT 5/12/22Earth Solutions NW, LLC 15365 N.E. 90th Street, Suite 100 Redmond, Washington 98052 Telephone: 425-449-4704 Fax: 425-449-4711