HomeMy WebLinkAbout22-102749-UP-Preliminary Drainage, Grading, and Right-of-Way Plan-06-15-2022-V1SD GRAPHIC D SCALE 100
( IN FEET )
1 inch = 50 ft.
VERTICAL DATUM: NGVD 29
LEGEND
FOUND MONUMENT AS NOTED
(
CALCULATED MONUMENT AS NOTED
(C)
CALCULATED DIMENSION
(M)
MEASURED DIMENSION
(Rx)
RECORD DOCUMENT (PER REFERENCE)
TPN
TAX PARCEL NUMBER
BOUNDARY LINE
— — — -- — — —
ADJOINER PROPERTY BOUNDARY
RIGHT OF WAY LINE
—
ROAD CENTERLINE
— — — — — —
EASEMENT LINE
-- - ---- - ---
SHORT PLAT LINE
— —
SECTION LINE
AREA COVERED BY CONTAINERS
(}
GATE POST
— a -— --
6' CHAIN LINK FENCE
--3c—a€-----
WROUGHT IRON FENCE
-------°-- - -
MINOR CONTOUR
---- —^- ----- -- --
MAJOR CONTOUR
x 0.0'
SPOT ELEVATION
0
SANITARY SEWER MANHOLE
O
SANITARY SEWER CLEANOUT
k
SANITARY SEWER STUB
Q
STORM MANHOLE
STORM CATCH BASIN
C
STORM CULVERT
-- sD -- SO — SD --
BURIED STORM DRAIN LINE
<- -- - - - E
STORM DITCH LINE
---ss --ss -- l� --
BURIED SANITARY SEWER LINE
IE
INVERT ELEVATION
PVC
PLASTIC PIPE
DI
DUCTILE IRON PIPE
RCP
REINFORCED CONCRETE PIPE
-O-
UTILITY POLE
YI
POWER VAULT
®
POWER METER
91
JUNCTION BOX
TRANSFORMER
LIGHT POLE
� 4
LIGHT POLE WITH ARM
IT
GAS VALVE
M
CABLE VAULT
[1
TELEPHONE RISER
M
WATER VALVE
E
WATER METER
0
IRRIGATION CONTROL VALVE
(j
UNKNOWN UTILITY MANHOLE
U
UNKNOWN UTILITY VAULT
—_0HE--OHE--
OVERHEAD POWER LINE
--OHT---OHT--
OVERHEAD TELEPHONE LINE
----G--G—G—G--
BURIED GAS LINE
ASPHALT SURFACE
CONCRETE SURFACE
GRAVEL SURFACE
IN,• wt maik
OVER SHEET
A PORTION OF THE SOUTH 1/2 OF THE S.E.1/4 OF SEC71ON 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M.,
CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON
r o�
i
fir`' t
1
.w
v
,
— t /
/
/ ) /
� LOTS
TPN 2021049 55.
I
��. 1
t t 1 'OFFICE 0 %�5HOP AND
r —;PARKING�a STORAGE
1�
6
_ _ 1 ,LOT 4
TPN 2021049043
1
i
GARBAGE1 CO E ED
v
1 RECYCLE DECA BINS
A)4 - ., ✓ l
-
SD
i
SD_ SD
e�a�so�
TPN 2021049148
TPN 1852950050
OWNER
SHEET INDEX
35000 PACIFIC HWY SOUTH, LLC
1.
COVER SHEET
P.O. BOX 94176
2.
GRADING AND TESC PLAN
SEATTLE, WA 98124-6476
3.
TESC NOTES AND DETAILS
PHONE: (253) 826-5020
4.
STORM PLAN
ENGINEER/SURVEYOR
5.
STORM PROFILES AND DETAILS
6.
STORM PROFILES
APEX ENGINEERING, LLC
7.
STORM PROFILES
2601 SOUTH 35TH, SUITE 200
8.
STORM NOTES AND DETAILS
TACOMA, WA 98409
9.
351ST STREET EAST PLAN AND PROFILE
PHONE: (253) 473-4494
10.
351ST STREET EAST GRADING DETAILS
11.
PACIFIC HWY SOUTH IMPROVEMENTS
12.
ROAD AND STORM DETAILS
13.
UTILITY PLAN
14.
BOUNDARY AND TOPOGRAPHIC SURVEY
— CONVEYOR
SILOS
TPN ✓ TPN 2 162 1
i
SILOS' �t
l
i � I
I
I 11
'I
r-
oz
fy ,7 I
I I
kOPPER`
6RA7FS- 'psD sn
TPN 2021049059
TPN
TPN 2021049116
VICINITY MAP
S 343RD ST
a
N
PARK NRIDE
S 344TH ST
S 347TH ST
S 348TH
ST
N
PARK N
RIDE
S 35 ND ST
N
WUNDARY/TOPOGRAPHY
SEE SHEET 14 OF 14 FOR BOUNDARY
AND TOPOGRAPHIC INFORMATION
SCALE: NTS
PLAN NOTES
1. LOCATIONS OF OFFSITE BUILDINGS AND DRIVEWAYS
FOR SURROUNDING AREA WERE OBTAINED FROM
AERIAL MAPPING AND ARE APPROXIMATE ONLY.
2. ADJACENT PROPERTY LINES WERE OBTAINED FROM
PUBLIC SOURCES AND ARE APPROXIMATE ONLY. TAX
PARCEL NUMBERS WERE OBTAINED FROM KING
COUNTY WEBSITE.
3. TO SCHEDULE A PRECONSTRUCTION MEETING OR
INSPECTION CONTACT THE CITYS PUBLIC WORKS
DEPARTMENT PRECONSTRUCTION/INSPECTION
NOTIFICATION PHONE NUMBER (253) 835-2700.
SITE AREA : 182,722 t SF. ( 4.2 t ACRES )
PARCEL NUMBERS : 202104-9043, 202104-9155,
202104-9162, 202104-9163
ZONING : CE ( COMMERCIAL ENTERPRISE
ON -SITE PAVING AND CURB : 163,025 f SF.
RIGHT OF WAY DEDICATION : 0 SF.
CRITICAL AREAS : 0 SF.
TRACT AREAS 0 SF.
OWNER/DEVELOPER: 35000 PACIFIC HWY SOUTH, LLC
35000 PACIFIC HWY S
FEDERAL WAY, WA 98003
LEGAL DESC EMPTION
LOTS 1, 2, 3 AND 4, KING COUNTY SHORT PLAT NUMBER
274023, RECORDED UNDER RECORDING NUMBER 8011050835, IN
KING COUNTY, WASHINGTON;
TOGETHER WITH THAT PORTION OF VACATED STATE HIGHWAY
ADJOINING SAID LOTS 3 AND 4, AS RECORDED UNDER
RECORDING NUMBERS 8212060518 AND 8212060520, AND
CORRECTED UNDER RECORDING NUMBERS 8307070635 AND
8307070636.
EXCEPT THOSE PORTIONS CONVEYED TO THE CITY OF FEDERAL
WAY BY INSTRUMENTS RECORDED UNDER RECORDING NUMBERS
20160108000112, 20160108000113 AND 20160108000115.
GRADING QUANi1ES:
CUT = 5,050 C.Y.
FILL = 1,450 C.Y.
NET = 3,600 C.Y. (CUT)
NOTE: QUANTITIES CALCULATED FROM EXISTING
GRADE TO FINISH GRADE WITH ROAD SECTION
TO SUBGRADE NOT REMOVED. STRIPPING OR
SOIL SUITABILITY NOT INCLUDED.
NOTE: THE ABOVE QUANTITIES ARE ESTIMATES
ONLY. THEY ARE INTENDED FOR THE PERMITTING
PROCESS. DO NOT USE FOR BID PURPOSES.
Know what'sbelow.
Cali before you dig.
NOTE:
THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER
APPROVAL DATE. THE CITY WILL NOT BE
RESPONSIBLE FOR ERRORS AND/OR OMISSIONS
ON THESE PLANS.
FIELD CONDITIONS MAY DICTATE CHANGES TO
THESE PLANS AS DETERMINED BY THE CITY
ENGINEER.
PERMIT NO. XX—XXXXXX—XX
APPROVED
DATE
1. CALL ONE -CALL LOCATE (811) FOR UTILITY LOCATES.
2. HOLD PRE -CONSTRUCTION CONFERENCE.
3. STAKE LIMITS OF CLEARING AND GRUBBING.
4. CLEAR AND GRUB AS NECESSARY TO INSTALL CONSTRUCTION
ENTRANCE AND FILTER FABRIC FENCES. INSTALL THOSE
FACILITIES/BMP'S.
5. COMPLETE CLEARING AND GRUBBING OF PROJECT, INSTALLING
EROSION CONTROL FACILITIES/BMP'S AS WORK PROGRESSES.
6. CONSTRUCT TEMPORARY SEDIMENT POND AND INTERCEPTOR SWALES.
7. INSTALL UTILITIES (SANITARY SEWER, STORM AND WATER), COMPLETE
GRADING, COVER SYSTEM AS WORK PROGRESSES.
PLANT 2 RELOCATION
GRADING AND TESC PLAN
A PORTION OF THE SOUTH 1/2 OF THE S.E.1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M.,
CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON
GRAPHIC SCALE'S
30 0 15 30 60
8. COMPLETE SITE GRADING. INSTALL EROSION CONTROL BMP S AS HIM
WORK PROGRESSES.
9. INSTALL REMAINING UTILITIES. INSTALL CB INSERTS AS WORK z/ ( IN FEET)
PROGRESSES. - 1 inch = 3: fV
10. MAINTAIN EROSION CONTROL FACILITIES/BMP'S. / / - - -17 VERTICAL DATUM: NGD 29 _ O
11. RELOCATE EROSION CONTROL FACILITIES/BMP'S OR INSTALL
NEW/ADDITIONAL MEASURES AS WEATHER CONDITIONS REQUIRE TO
PREVENT SEDIMENT LADEN RUNOFF FROM LEAVING THE SITE.
12. INSTALL REMAINING SITE IMPROVEMENTS, I.E. ROADWAYS, CURB, DRY
UTILITIES SIDEWALK AND PAVEMENT.
13. HYDROSEED, FERTILIZE AND MULCH ALL DISTURBED AREAS.
14. COVER ALL DISTURBED AREAS PER SEASONAL REQUIREMENTS FOR
SITE STABILIZATION.
15. CLEAN STORM DRAINAGE SYSTEM.
16. AFTER SITE IS STABILIZED AND WITH CITY OF FEDERAL WAY
APPROVAL, REMOVE ALL EROSION CONTROL FACILITIES/BMP'S.
RIP RAP NOTES _
RIP RAP SHALL BE IN ACCORDANCE WITH SECTION 9-13.1 OF THE
WSDOT/APWA STANDARD SPECIFICATIONS. RIP RAP TO BE REASONABLY 2
WELL GRADED WITH ROCK GRADATION AS FOLLOWS:
1. PASSING 8 INCH SQUARE SIEVE 100% OR MAXIMUM STONE SIZE 8"
PASSING 6 INCH SQUARE SIEVE 40-60% OR MEDIAN STONE SIZE 6"
PASSING 2 INCH SQUARE SIEVE 0-10% OR MINIMUM STONE SIZE 2"
�jy/ �
n / d
8
i%
Cd
j
r
2
U
i/ / k�9
IF
MD ° d°
e
;,.
a
LAB=255.
°
a
a
°d
� a
a
°
g
VIP
-VT
d
e..
°
1-14
°
a
Fo
° a
yr 2�gNIL
d
10� ed
:�
ad
e
°
da
°
d
° n
v
°. d <
v
d
a n
d
°
e n ^
�
-•
/ / MU N d'
° a a
n e ° 41� 6 d
°
4 d ° ai 1e' d M
n d
14 d M•�
d 1.
4\
a
FF=254.00
d
° a -I
4 a AA ,gyp/ < ° ° °4 ^4 °
253.95 d SF
253.90 p ? IS 4
e
?S ° °
°
/ °>�• °'.� °.a a d° n ° .J� ryy3. a°.4°° °° siJa� � hy�J ® ° a_', ° °� d. •�?
<°IK
°. a a ° d ° ° a a a ° d ° ` a� °N - d� 250
11 - 4 4
° a ° d � d 1 A i d MU < a $ BO
4 ° °
e e.
t -� r
�/ 1 d ° by ° d a ° e °° d ° I, _ Sf; �- �D S> �> / 2 e
° d ° e 0
d a
° g° ��51 ryIS5.1 °
° d ° v d ° °
e B n a e d° e°
a °
d ,
/i' 1 / � � Lam• q' d° ° in . 4° a .�- � " {?�. ° I
5
IF
�( dV a v Va V
-
IF
/ ©1
J3
o
10 0
-
3
/ 5 g-c--c-c_3 G
D_
-SD-SD-SD- D SD-SD-SD--6 -SD =, D-S P
�0 - SD SD �- S - S SD -,. SD
SD -- SD - SD
IF
SDSD SD -SD-��
16 SF 6 4
CL� A SO
I �o
✓' !! O I fQ
NO
,
°
dll
d° a�
d
0 4
d c
° 41
°° a °
.4
°
a d (
44
° ���'\/
d
'-'
a9ii li
'4 b dl
14
4
d'
d ^
v
e n d
° e
°
- - d°
a4 ° I
°
a
° I'
L\
d°
--
d
°
e
a 3
°
<•
ad
d
'YV
p°
°ad
°
°
dQ
° °
d
I
T
d V °
4 d
SF
Al
e A'
as4
d
°
d a
a
d,.
°
°®
d� e
°<d
° d
� Sp
TESC LEGEND
© CLEARING LIMITS
INTERCEPTOR SWALE 0 0.5%
MIN. SLOPE, PER DETAIL SHT 3.
-X-X-X- S© SILT FENCE, PER DETAILS SHT 3,
IP CATCH BASIN INSERT, PER DETAILS SHT 3.
Q SEDIMENT POND, PER DETAILS SHT 3.
(MIN. SURFACE AREA AT RISER ELEV
= 2,375 SF)
© STABILIZED CONSTRUCTION ENTRANCE,
PER DETAILS SHT 3.
® RIP RAP, PER NOTES SHT 3.
® Q CHECK DAM, PER DETAILS SHT 3,
I
MU HYDROSEED, FERTILIZER AND MULCH,
PER NOTE SHT 3.
0 APPROXIMATE SOIL STOCKPILE
�- - LOCATION.
A
CO113TRlJC710N
NOTES
1 I
EXISTING UTILITY POLE TO REMAIN, PROTECT DURING CONSTRUCTION
1
j
02
EXISTING CATCH BASIN TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST
TO FINISH GRADE AS NECESSARY
Q3
EXISTING SANITARY SEWER TO REMAIN, PROTECT DURING CONSTRUCTION AND
I
ADJUST TO FINISH GRADE AS NECESSARY. CONTRACTOR TO COORDINATE WITH
LAKEHAVEN WATER AND SEWER DISTRICT AS NECESSARY.
i
®
EXISTING WATER VALVE TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST
�Y
TO FINISH GRADE AS NECESSARY. CONTRACTOR TO COORDINATE WITH LAKEHAVEN
WATER AND SEWER DISTRICT AS NECESSARY.
0
EXISTING GAS VALVE TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST TO
FINISH GRADE AS NECESSARY
©
EXISTING TRANSFORMER TO REMAIN, PROTECT DURING CONSTRUCTION. CONTRACTOR
TO COORDINATE WITH PUGET SOUND ENERGY AS NECESSARY.
Q7
EXISTING WATER METER TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST
TO FINISH GRADE AS NECESSARY. CONTRACTOR TO COORDINATE WITH LAKEHAVEN
1
WATER AND SEWER DISTRICT AS NECESSARY.
®
EXISTING LIGHT POLE TO BE RELOCATED, CONTRACTOR TO COORDINATE WITH PUGET
SOUND ENERGY, WSDOT, AND CITY OF FEDERAL WAY AS NECESSARY
Q
EXISTING FENCE TO BE REMOVED
D
EXISTING LIGHT POLE TO BE REMOVED
(5
EXISTING BLOCK WALL TO BE REMOVED
1©
EXISTING CATCH BASIN/PIPE TO BE REMOVED
Q
EXISTING IRRIGATION CONTROL VALVE TO BE REMOVED/RELOCATED AS NECESSARY
®
EXISTING UTILITY POLE TO BE RELOCATED, CONTRACTOR TO COORDINATE WITH
PUGET SOUND ENERGY AS NECESSARY
��
15
EXISTING CULVERT TO BE REMOVED
16
EXISTING FENCE TO REMAIN, PROTECT DURING CONSTRUCTION
1©
EXISTING FENCE TO BE RELOCATED, COORDINATE WITH ADJACENT PROPERTY OWNER
AS NECESSARY
EXISTING UTILITY VAULT TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST
TO FINISH GRADE AS NECESSARY. CONTRACTOR TO COORDINATE WITH PUGET SOUND
�k0
ENERGY AS NECESSARY.
/N
Ig
EXISTING BUILDING TO BE REMOVED
5D - ®
EXISTING CONCRETE TO BE REMOVED
©1
EXISTING ASPHALT TO BE REMOVED
i GEOTECHNICAL NOTES
1. EARTHWORK AND MATERIALS SHALL CONFORM TO THE RECOMMENDATIONS PER THE
GEOTECHNICAL ENGINEER. STRUCTURAL FILL AND FILL SOILS SHALL BE EVALUATED AND
ACCEPTED BY THE GEOTECHNICAL ENGINEER PRIOR TO USE.
I
2. THE GEOTECHNICAL ENGINEER OR DESIGNATED REPRESENTATIVE SHALL BE ON SITE TO
OBSERVE EARTHWORK AS NECESSARY.
NOTE:
THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER
APPROVAL DATE. THE CITY WILL NOT BE
RESPONSIBLE FOR ERRORS AND/OR OMISSIONS
ON THESE PLANS.
FIELD CONDITIONS MAY DICTATE CHANGES TO
THESE PLANS AS DETERMINED BY THE CITY
ENGINEER.
Know what's below.
Call before you dig.
PERMIT NO. XX-XXXXXX-XX
APPROVED
DATE
EQUIVALENT�-JONTS IN FILTER FABRIC SHALL BE SPLICED
AT POSTS. USE STAPLES, WIRE RINGS OR PLANT 2 RELOt"", A TION
1 ATTACH FABRIC TO POSTS.
I' 'GGi:T.:::::::::::000 . 1 ' ii NOTESTESC . .
/:/::::::::i/::i:...
p
0000/n.uuu.
EQUIVALENT, IF STANDARD
o.n...FABRICUSED
_ _
TI
................
/.ON OF THE SOUTH 1/2 OF THE S E 114 OF SECTION 20, TOWNSHIP 21 NORTH,
RANGE 4 EAST, W.M.
. • 1
................FILTER ...............
.............
.............
.............MY OF FEDERAL WAY, KING COUNTY, WASHINGTON
6' MAX. ► J-
POST SPACING MAY BE � MINIMUM 4"x4" TRENCH
INCREASED TO 8' IF BACKFILL TRENCH WITH NATIVE SOIL
WIRE BACKING IS USED OR 3/4" TO 1-1/2" WASHED GRAVEL
NOTE: FILTER FABRIC FENCES
SHALL BE INSTALLED ALONG 2"x4" WOOD POSTS, STEEL FENCE
CONTOURS WHENEVER POSSIBLE POSTS, REBAR, OR EQUIVALENT
MAINTENANCE STANDARDS
1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY.
2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND
CONVEYED TO A SEDIMENT TRAP OR POND.
1 IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND
ACTING AS A BARRIER TO FLOW AND MEN CAUSING CANALIZATION OF FLOWS PARALLEL TO THE FENCE.
IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT.
4. SEDIMENT MUST BE REMOVED WHEN THE SEDIMENT IS 6 INCHES HIGH.
5. 5. IF THE FILTER FABRIC (GEOTEXPLE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL
BE REPLACED. SILT FENCE
(K.C. FIG. C.16,A)
SWALE SPACING DEPENDS ON SLOPE GRADIENT
MAINTENANCE STANDARDS
1. DAMAGE RESULTING FROM RUNOFF OR CONSTRUCTION ACTIVITY SHALL BE REPAIRED IMMEDIATELY.
2. IF THE FACILITIES DO NOT REGULARLY RETAIN STORM RUNOFF, THE CAPACITY AND/OR FREQUENCY OF
THE DIKES/SWALES SHALL BE INCREASED.
INTERCEPTOR SWALE
(K.C. FIG. C.3.128)
N.T.S.
ROCK MUST COMPLETELY COVER
THE BOTTOM AND SIDES OF THE DITCH
6" MIN.
24" MIN.
2H:IV SLOPES
L=THE DISTANCE SUCH THAT POINTS
A AND B ARE OF EQUAL ELEVATION
2"- 4„
L ate. I -ROCK
CHECK DAM SPACING
CHECK DAMS
(K.C. FIG. C.3.13.A)
N.T.S.
25' MIN.
�4"- B" QUARRY WON
IF A ROADSIDSPALLS
E DITCH ISPROVIDE FULL WIDTH OF
PRESENT, INSTALL GEOTEX77LE
DRIVEWAY CULVERT PER INGRESS/EGRESS AREA
KCRDCS 12" MIN.
NOTES: THICKNESS
. PER KING COUNTY ROAD DESIGN AND CONSTRUCTION STANDARDS (KCRDCS), DRIVEWAYS SHALL BE
PAVED TO EDGE OF R-O-W PRIOR TO INSTALLATION OF THE CONSTRUCTION ENTRANCE TO AVOID
DAMAGING OF THE ROADWAY.
IT IS RECOMMENDED THAT THE ENTRANCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD.
MAINTENANCE STANDARDS
1. QUARRY SPALLS (OR HOG FUEL) SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH
THE SPECIFICATIONS.
2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN
ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY
INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE
INSTALLATION OF A WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED
WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND.
3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING.
THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT
SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE
AND THERE IS A THREAT TO PUBLIC IF IT IS NECESSARY TO WASH THE STREETS, A SMALL SUMP
MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE
CONTROLLED. WASH WATER MUST BE PUMPED BACK ONTO THE SITE AND CANNOT DISCHARGE TO
SYSTEMS TRIBUTARY TO SURFACE WATERS.
4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE
REMOVED IMMEDIATELY.
5. IF VEHICLES ARE ENTERING OR EXITING THE SITE AT POINTS OTHER THAN THE CONSTRUCTION
ENTRANCE(S), FENCING (SEE SECTION 0.2.1.1) SHALL BE INSTALLED TO CONTROL TRAFFIC.
STABILIZED CONSTRUCTION ENTRANCE
(K.C. FIG. D.21.4.A)
N.T.S.
SOLID WALLS
FILTER MEDIA -
FOR
DEWATERING
CATCH BASIN GRATE
OVERFLOW
;
j
POROUS
BOTTOM
NOTE: THIS DETAIL IS ONLY
SCHEMATIC. ANY INSERT IS
ALLOWED THAT HAS:
• A MIN. 0.5 C.F. OF STORAGE,
-THE MEANS TO DEWATER THE
STORED SEDIMENT,
• AN OVERFLOW, AND
• CAN BE EASILY MAINTAINED.
MAINTENANCE STANDARDS
1. ANY ACCUMULATED SEDIMENT ON OR AROUND INLET PROTECTION SHALL BE REMOVED IMMEDIATELY.
SEDIMENT SHALL NOT BE REMOVED WITH WATER, AND ALL SEDIMENT MUST BE DISPOSED OF AS FILL ON
SITE OR HAULED OFF SITE.
2. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED
ONE-THIRD OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR
REPLACED AT LEAST MONTHLY.
3. REGULAR MAINTENANCE IS CRITICAL FOR ALL FORMS OF CATCH BASIN/INLET PROTECTION. UNLIKE MANY
FORMS OF PROTECTION THAT FAIL GRADUALLY, CATCH BASIN PROTECTION WILL FAIL SUDDENLY AND
COMPLETELY IF NOT MAINTAINED PROPERLY.
CATCH BASIN INSERT
(KC. FIG. C3.9.8)
N.T.S.
KEY DIVIDER INTO SLOPE TO -
PREVENT FLOW AROUND SIDES
THE POND LENGTH SHALL
BE 3 TO 6 TIMES THE
MAXIMUM POND WIDTH
EMERGENCY
OVERFLOW
SPILLWAY
+•-::
DI R ETD
STABILIZED
CONVEYANCE,
EQUIVALENTSIL FENCE 0 OUTLET OR LEVEL
��SPREADER
DIVIDER
NOTE:
POND MAY BE FORMED BY BERM OR BY
PARTIAL OR COMPLETE EXCAVATION
SEDIMENT POND PLAN VIEW
(K.C. FIG. 0.2.1.5.B)
N.T.S.
RISER PIPE (PRINCIPAL
CREST OF 6' MIN. BERM WIDTH
SPILLWAY) OPEN AT TOP WITH
EMERGENCY
EMBANKMENT
TRASH RACK PER FIG. 5.1.1.0
SPILLWAY
COMPACTED 95%
MODIFIED PROCTOR.
DEWATERING
rj
PERVIOUS MATERIALS
DEVICE (SEE
�L
SUCH AS GRAVEL OR
RISER DETAIL)
r-='
CLEAN SAND SHALL
NOT BE USED.
WIRE -BACKED SILT -�
FENCE, STAKED STRAW DEWATERING
BALES WRAPPED WITH ORIFICE DISCHARGE TO STABILIZED
FILTER FABRIC, OR CONCRETE BASE CONVEYANCE, OUTLET OR
EQUIVALENT DIVIDER (SEE RISER DETAIL) LEVEL SPREADER
SEDIMENT POND CROSS SECTION
(K.C. FIG. D.2.1.5.C)
N.T.S.
POLYETHYLENE CAP
PERFORATED
DEWATERING DEVICE,
SEE NOTE
PROVIDE
ADEQUATE
STRAPPING
2RUGATE
TAL RISER 3.5' MIN.
TACK DEWATERING ORIFICE,
WELD I SCHEDULE 40 STEEL
STUB MIN. DIAMETER
AS PER CALCULATIONS
NOTE:
I
T-
PERFORATED CORRUGATED
6" MIN
POLYETHYLENE(CPE)
DRAINAGE TUBING, DIAMETER 18" IN
}
MIN. 2" LARGER THAN
DEWATERING ORIFICE. TUBING
I
CONCRETE BASE
ALTERNATIVELY, METAL
SHALL COMPLY WITH ASTM
STAKES AND WIRE MAY
F667 AND AASHTO M294.
BE USED TO PREVENT
2X RISER DIA, MIN..
FLOTATION
SEDIMENT POND RISER DETAIL
(K.C. FIG, D.2J.5.19)
N.T.S.
INFILTRATION FACILITY NOTES:
1. DURING CONSTRUCTION AND UNTIL SITE IS COMPLETELY STABILIZED, NO RUNOFF SHALL DISCHARGE
DIRECTLY INTO THE INFILTRATION SYSTEM.
2. THE GEOTECHNICAL ENGINEER IS TO INSPECT THE FACILITY BEFORE, DURING, AND AFTER
CONSTRUCTION TO ENSURE THE FACILITY IS CONSTRUCTED CORRECTLY, THAT THE INFILTRATION
SURFACE IS NOT COMPACTED AND THE SYSTEM IS PROTECTED FROM SEDIMENTATION. CONTRACTOR
SHALL COORDINATE.
3. IMMEDIATELY AFTER FACILITY EXCAVATION/CONSTRUCTION, THE GEOTECHNICAL ENGINEER IS TO
PERFORM A SUFFICIENT NUMBER OF INFILTRACTION TESTS (2 MINIMUM) TO VERIFY IF THE
INFILTRATION RATES AND DEPTHS TO GROUND WATER AND/OR IMPERVIOUS SOIL LAYER USED FOR
DESIGN ARE S71LL ACCEPTABLE. IF TESTS INDICATE THAT THE FACILITY WILL NOT FUNCTION AS
DESIGNED, THIS INFORMATION SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CITY OF
LACEY AND APEX ENGINEERING PLLC. CONTRACTOR SHALL COORDINATE.
4. BOTTOMS OF INFILTRATION SYSTEMS SHALL NOT BECOME COMPACTED. LIMIT CONSTRUCTION
VEHICLE ACCESS AT ALL TIMES,
5. AFTER INSTALLATION, DELINEATE THE IMMEDIATE AREA WITH PROTECTION FENCING TO PREVENT
VEHICLES/TRAFFIC TRAVERSING THE INFILTRATION SYSTEM AREA. PROTECT AREA AT ALL TIMES.
6. CONFORM TO THE RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER.
KING COUNTY MULCHING NOTES
AS A TEMPORARY COVER MEASURE, MULCH SHOULD BE USED:
1. ON DISTURBED AREAS THAT REQUIRE COVER MEASURES FOR LESS THAN 30 DAYS.
2. AS A COVER FOR SEED DURING THE WET SEASON AND DURING THE HOT SUMMER MONTHS.
3. DURING THE WET SEASON ON SLOPES STEEPER THAN 3H:1V WITH MORE THAN 10 FEET OF
VERTICAL RELIEF.
MAINTENANCE STANDARDS:
1. THE THICKNESS OF THE MULCH COVER MUST BE MAINTAINED.
2. ANY AREAS THAT EXPERIENCE EROSION SHALL BE RE -MULCHED AND/OR PROTECTED WITH A NET
OR BLANKET. IF THE EROSION PROBLEM IS DRAINAGE RELATED, THEN THE DRAINAGE PROBLEM
SHALL BE ASSESSED AND ALTERNATE DRAINAGE SUCH AS INTERCEPTOR SWALES MAY BE NEEDED
TO FIX THE PROBLEM AND THE ERODED AREA RE -MULCHED.
MULCH STANDARDS AND GUIDELINES:
• STRAW: 2"TO 3"THICK, 2-3 BALES PER 1,000 SF OR 2-3 TONS PER ACRE
• WOOD FIBER CELLULOSE: APPROXIMATELY 25-30 LBS PER 1,000 SF OR 1,000 TO 1,500 LBS PER
ACRE
• COMPOST: 2"THICK MIN., APPROXIMATELY 100 TONS PER ACRE (APPROXIMATELY 800 LBS PER
CUBIC YARD)
• HYDRAULIC MATRICES (BONDED FIBER MATRIX): APPLY AT RATES FROM 3,000 LBS PER ACRE TO
4,000 LBS PER ACRE AND BASED ON MANUFACTURERS'RECOMMENDATIONS.
• CHIPPED SITE VEGETATION: 2"THICK MIN.
EROSION/SEDIMENT CONTROL NOTES-
1. APPROVAL OF THIS EROSION/SEDIMENTATION CONTROL (ESC) PLAN DOES NOT CONSTITUTE AN
APPROVAL OF PERMANENT ROAD OR DRAINAGE DESIGN (I.E. SIZE AND LOCATION OF ROADS, PIPES,
RESTRICTORS, CHANNELS, RETENTION FACILITIES, UTILITIES, ETC.).
Z THE IMPLEMENTATION OF THESE ESC PLANS AND THE CONSTRUCTION, MAINTENANCE, REPLACEMENT,
AND UPGRADING OF THESE ESC FACILITIES IS THE RESPONSIBILITY OF THE APPLICANT/CONTRACTOR UN71L
ALL CONSTRUCTION IS APPROVED.
3. THE BOUNDARIES OF THE CLEARING LIMITS SHOWN ON THIS PLAN SHALL BE CLEARLY FLAGGED IN THE
FIELD PRIOR TO CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE
FLAGGED CLEARING LIMITS SHALL BE PERMITTED. THE FLAGGING SHALL BE MAINTAINED BY THE
APPLICANT/CONTRACTOR FOR THE DURATION OF CONSTRUCTION.
4. THE ESC FACILITIES SHOWN ON THIS PLAN MUST BE CONSTRUCTED IN CONJUNCTION WITH ALL CLEARING
AND GRADING ACTIVITIES, AND IN SUCH A MANNER AS TO INSURE THAT SEDIMENT LADEN WATER DOES
NOT ENTER THE DRAINAGE SYSTEM OR VIOLATE APPLICABLE WATER STANDARDS.
5. THE ESC FACIU77ES SHOWN ON THIS PLAN ARE THE MINIMUM REQUIREMENTS FOR ANTICIPATED SITE
CONDITIONS. DURING THE CONSTRUCTION PERIOD, THESE ESC FACILITIES SHALL BE UPGRADED (I.E.
ADDITIONAL SUMPS, RELOCATION OF DITCHES AND SILT FENCES, ETC.) AS NEEDED FOR UNEXPECTED
STORM EVENTS.
6. THE ESC FACILITIES SHALL BE INSPECTED DAILY BY THE APPLICANT/CONTRACTOR AND MAINTAINED AS
NECESSARY TO ENSURE THEIR CONTINUED FUNCTIONING.
7. ANY AREA STRIPPED OF VEGETATION, INCLUDING ROADWAY EMBANKMENTS, WHERE NO FURTHER WORK
IS ANTICIPATED OR A PERIOD OF 2 DAYS (WET SEASON) OR 7 DAYS (DRY SEASON), SHALL BE
IMMEDIATELY STABILIZED WITH THE APPROVED ESC METHODS (I.E. SEEDING, MULCHING, NETTING, EROSION
BLANKETS, ETC.)
8. ANY AREA NEEDING ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED
WITHIN 15 DAYS.
9. THE ESC FACILITIES ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED A MINIMUM OF ONCE A
MONTH OR WITHIN THE 24 HOURS FOLLOWING A STORM EVENT.
10. AT NO TIME SHALL MORE THAN ONE FOOT OF SEDIMENT BE ALLOWED TO ACCUMULATE WITHIN A
CATCH BASIN. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE
CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM.
11. STABILIZED CONSTRUCTION ENTRANCES AND WASH PADS SHALL BE INSTALLED AT THE BEGINNING OF
CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES MAY BE
REQUIRED TO INSURE THAT ALL PAVED AREAS ARE KEPT CLEAN FOR THE DURATION OF THE PROJECT.
12. WET SEASON REQUIREMENTS AS DESCRIBED IN APPENDIX D, SECTION D.2.4.2 OF THE KCSWDM ARE IN
EFFECT BEGINNING OCTOBER 1 THROUGH APRIL 30.
13. ANY PERMANENT RETENTION/DETENTION FACILITY USED AS A TEMPORARY SETTLING BASIN SHALL BE
MODIFIED WITH THE NECESSARY EROSION CONTROL MEASURES AND SHALL PROVIDE ADEQUATE STORAGE
CAPACITY. IF THE PERMANENT FACILITY IS TO FUNCTION ULTIMATELY AS AN INFILTRATION OR DISPERSION
SYSTEM, THE FACILITY SHALL NOT BE USED AS A TEMPORARY SETTLING BASIN. NO UNDERGROUND
DETENTION TANKS OR VAULTS SHALL BE USED AS A TEMPORARY SETTLING BASIN.
14. WHERE SEEDING FOR TEMPORARY EROSION CONTROL IS REQUIRED, FAST GERMINATING GRASSES
SHALL BE APPLIED AT AN APPROPRIATE RATE (I.E. ANNUAL OR PERENNIAL RYE APPLIED AT
APPROXIMATELY 80 POUNDS PER ACRE).
15. WHERE STRAW MULCH FOR TEMPORARY EROSION CONTROL IS REQUIRED, IT SHALL BE APPLIED AT A
MINIMUM THICKNESS OF TWO INCHES.
16. MANAGEMENT PRACTICES PROVIDING SIGNIFICANT TREE PROTECTION SHALL BE PROVIDED PER
SECTION 19.120 OF FWRC.
111 ►l_ ►�� a ll
•ii �; m 111�� ► ,
SEEDING NOTES
1. THE BEST TIME TO SEED IS APRIL 1 THROUGH JUNE 30, AND SEPTEMBER 1 THROUGH
OCTOBER 15. AREAS MAY BE SEEDED BETWEEN JULY 1 AND AUGUST 31, BUT IRRIGATION MAY
BE REQUIRED IN ORDER TO GROW ADEQUATE COVER. AREAS MAY ALSO BE SEEDED DURING
THE WINTER MONTHS, BUT IT MAY TAKE SEVERAL MONTHS TO DEVELOP A DENSE
GROUNDCOVER DUE TO COLD TEMPERATURES. THE APPLICATION AND MAINTENANCE OF MULCH
IS CRITICAL FOR WINTER SEEDING.
Z TO PREVENT SEED FROM BEING WASHED AWAY, CONFIRM THAT ALL REQUIRED SURFACE WATER
CONTROL MEASURES HAVE BEEN INSTALLED.
3. THE SEEDBED SHOULD BE FIRM BUT NOT COMPACTED BECAUSE SOILS THAT ARE WELL
COMPACTED WILL NOT VEGETATE AS QUICKLY OR THOROUGHLY.
4. IN GENERAL, 10-20-20 N-P-K (NITROGEN -PHOSPHORUS -POTASSIUM) FERTILIZER MAY BE
USED AT A RATE OF 90 POUNDS PER ACRE. SLOW -RELEASE FERTILIZERS ARE PREFERRED
BECAUSE THEY ARE MORE EFFICIENT AND HAVE FEWER ENVIRONMENTAL IMPACTS. IT IS
RECOMMENDED THAT AREAS BEING SEEDED FOR FINAL LANDSCAPING CONDUCT SOIL TESTS TO
DETERMINE THE EXACT TYPE AND QUANTITY OF FERTILIZER NEEDED. THIS WILL PREVENT THE
OVERAPPLICATION OF FERTILIZER. DISTURBED AREAS WITHIN 200 FEET OF WATER BODIES AND
WETLANDS MUST USE SLOWRELEASE LOW -PHOSPHORUS FERTILIZER (TYPICAL PROPORTIONS
3-1-2 N-P-K).
5. THE FOLLOWING REQUIREMENTS APPLY TO MULCHING:
0. MULCH IS ALWAYS REQUIRED FOR SEEDING SLOPES GREATER THAN 3H:IV (SEE SECTION
D.4.2.1 OF THE 2016 KING COUNTY SURFACE WATER DESIGN MANUAL).
b. IF SEEDING DURING THE WET SEASON, MULCH IS REQUIRED.
c. THE USE OF MULCH MAY BE REQUIRED DURING THE DRY SEASON AT THE COUNTYS
DISCRETION IF GRASS GROWTH IS EXPECTED TO BE SLOW, THE SOILS ARE HIGHLY ERODIBLE
DUE TO SOIL TYPE OR GRADIENT, THERE IS A WATER BODY CLOSE TO THE DISTURBED
AREA, OR SIGNIFICANT PRECIPITATION IS ANTICIPATED BEFORE THE GRASS WILL PROVIDE
EFFECTIVE COVER.
d. MULCH MAY BE APPLIED ON TOP OF THE SEED OR SIMULTANEOUSLY BY HYDROSEEDING.
6. HYDROSEEDING IS ALLOWED AS LONG AS TACKIFIER IS INCLUDED. HYDROSEEDING WITH WOOD
FIBER MULCH IS ADEQUATE DURING THE DRY SEASON. DURING THE WET SEASON, THE
APPLICATION RATE SHALL BE DOUBLED BECAUSE THE MULCH AND TACKIFIER USED IN
HYDROSEEDING BREAK DOWN FAIRLY RAPIDLY. IT MAY BE NECESSARY IN SOME APPLICATIONS
TO INCLUDE STRAW WITH THE WOOD FIBER, BUT THIS CAN BE DETRIMENTAL TO GERMINATION.
Z AREAS TO BE PERMANENTLY LANDSCAPED SHALL USE SOIL AMENDMENTS. GOOD QUALITY
TOPSOIL SHALL BE TILLED INTO THE TOP SIX INCHES TO REDUCE THE NEED FOR FERTILIZER
AND IMPROVE THE OVERALL SOIL QUALITY. MOST NATIVE SOILS WILL REQUIRE THE ADDITION
OF FOUR INCHES OF WELL -ROTTED COMPOST TO BE TILLED INTO THE SOIL TO PROVIDE A
GOOD QUALITY TOPSOIL. COMPOST USED SHOULD MEET SPECIFICATIONS IN REFERENCE 11-C
OF THE 2016 KING COUNTY SURFACE WATER DESIGN MANUAL
8. THE SEED MIXES LISTED BELOW INCLUDE RECOMMENDED MIXES FOR BOTH TEMPORARY AND
PERMANENT SEEDING. THESE MIXES, WITH THE EXCEPTION OF THE WETLAND MIX, SHALL BE
APPLIED AT A RATE OF 120 POUNDS PER ACRE. THIS RATE MAY BE REDUCED IF SOIL
AMENDMENTS OR SLOW -RELEASE FERTILIZERS ARE USED. LOCAL SUPPLIERS SHOULD BE
CONSULTED FOR THEIR RECOMMENDATIONS BECAUSE THE APPROPRIATE MIX DEPENDS ON A
VARIETY OF FACTORS, INCLUDING EXPOSURE, SOIL TYPE, SLOPE, AND EXPECTED FOOT TRAFFIC.
ALTERNATIVE SEED MIXES APPROVED BY THE COUNTY MAY BE USED.
% WEIGHT % PURITY % GERMINATION
CHEWINGS OR RED FESCUE (FESTUCA RUBRA 40 98 90
VAR. COMMUTATA OR FESTUCA RUBRA)
ANNUAL OR PERENNIAL RYE 40 98 90
(LOLIUM MULTIFLORUM OR LOLIUM PERENNE)
REDTOP OR COLONIAL BENTGRASS 10 92 85
(AGROSTIS ALBA OR AGROSTIS TENUIS)
WHITE DUTCH CLOVER (TRIFOLIUM REPENS) 10 98 90
MAINTENANCE STANDARDS FOR SEEDING:
1. ANY SEEDED AREAS THAT FAIL TO ESTABLISH AT LEAST 80 PERCENT COVER WITHIN ONE
MONTH SHALL BE RESEEDED. IF RESEEDING IS INEFFECTIVE, AN ALTERNATE METHOD, SUCH AS
SODDING OR NETS/BLANKETS, SHALL BE USED. IF WINTER WEATHER PREVENTS ADEQUATE
GRASS GROWTH, THIS 71ME LIMIT MAY BE RELAXED AT THE DISCRETION OF THE COUNTY WHEN
CRITICAL AREAS WOULD OTHERWISE BE PROTECTED.
2. AFTER ADEQUATE COVER IS ACHIEVED, ANY AREAS THAT EXPERIENCE EROSION SHALL BE
RE -SEEDED AND PROTECTED BY MULCH. IF THE EROSION PROBLEM IS DRAINAGE RELATED,
THE PROBLEM SHALL BE FIXED AND THE ERODED AREA RE -SEEDED AND PROTECTED BY
MULCH.
3. SEEDED AREAS SHALL BE SUPPLIED WITH ADEQUATE MOISTURE, BUT NOT WATERED TO THE
EXTENT THAT IT CAUSES RUNOFF.
Know what's below.
Call before you dig.
NOTE:
THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER
APPROVAL DATE. THE CITY WILL NOT BE
RESPONSIBLE FOR ERRORS AND/OR OMISSIONS
ON THESE PLANS.
FIELD CONDITIONS MAY DICTATE CHANGES TO
THESE PLANS AS DETERMINED BY THE CITY
ENGINEER.
PERMIT NO. XX-XXXXXX-XX
APPROVED
DATE
GRAPHIC SCALE
PLAN NOTES
Qi COALESCING PLATE OIL/WATER SEPARATOR
30 0 15 30 60 OLDCASILE PRECAST MODEL 816-2-CPS
A PORTION OF THE SOUTH 112 OF THE S.E" 114 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M., W/ HEAVY TRAFFIC LID/TOP
CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON PER DETAIL 6 SHEET 8
( IN FEET) _ -- II..E. 8" IN () (CENTER OF LID)
1 inch - 30 ft. / / - -- 252 (W) = 244.47
VERTICAL DATUM: NGVD 29 I.E. 8" OUT
Q2 PRESETfL1NG VAULT
SEE DETAIL ON SHEET 7
I.E. 18" (S) = 242.520
/ I.E. 8" (E) = 242.50
256 - r. I.E. 18" (N) = 243.50
- ° d
254 d° Q3 BIOPOD BIOFILTER
a s d MODEL BPU-8161B
° d ° SEE DETAIL ON SHEET 8
/ J , < RIM = 252.28 (CENTER OF VAULT)
/! I.E. IN 18" (S) = 243.46
g d
255 d 253 ° ° d I.E. OUT 18" (N) = 242.96
d°
�STC9 4, T-)p I ® INFILTRATION VAULT
/ $T�, +54.52, 344 48' L d d , SEE DETAIL ON SHEET 7
4 4 < STCB 51 TlP r ° ° a \ ? s ° ° d I.E. 18" (E) = 242.85
„STOMSTA: 14+95t5 , 311;99 L
/' 252 50 °/ 91 12, ADS N-12 0 1:45% 86 LF 12" A =1' ®°p.50%° yd °d ° FORTRANS 5000E
CB#13, TYPE 1 ® a - -°- - a ,�d PH CONTROL SYSTEM
STA 12 "16.14, 32j4,2. L c ° OR APPROVED EQUAL
° STCB#i6; TYPE 1° e\ °
°d
/ \a / a ° STA; 15+72.88 274^5b� L d
i ! n d A a
I°
°
"
°
°
a \
° °
p 2 " p I,
/ B#10, TYPE 48 0 q d ° a I d
�tCB#it, TYPE 1 I
ST 11186.82, 238.11' L a /° 12+59.8, 2652 a `�°d a a R
°
d
gI I I 1 d
qt
,,,`U Cf)° �s ° S N-12a ZO STCB'#12.°°IYPE,IL C �i
I %/ 12� Pp STA: 15+ 1°9$, 174.5$' L d
,� ° 44vv,,TT��
/ /� < '�° ° d�
251. d I VAULT 242.8 _ \\° tea- .1 - 1-4 ° <
Q d S 12+29.6 - -°` - = P a -
#° °
/ " a ,I A A DRAIN 1 °
9 f8" ADS N= 2 0 0.56% d a
OfST B#f, TYPE 2 480 A: 14+57:76, k70.40r. Cn d
° ° I S Af 12+38.05; 1 8.91' L I„ ° °I a d
LF 18" ADS N 2 @ 1.00% 2S?
< 168 LF 12" A S N-12 00.78% { a °°
7 LF 1$" ADS' -12 @ 0.57%
ad �
a "� wry- ° ° � ° a, ° VCVjpyi TYPE 1,
° ° ° I ��
�d ° I I 251 STA: 15+33.74,° 48.0
d I d °'� , r I° a
< ° d °1 d �35 LF 11 'ADS--12
249 �� J ± L---- _- °- -- - °
/ - 24 LF 7 8"^AOS',N-12°O 28,14% a= a °STCB#6 E 2;- `q
18" ADS N�i2 8 " d 'STA: 14+ 8.51, 48 0' L
d° 8 LF 8 ADS N-12 ®1.00% ° a \
% 4, 10.04% ° d °
d
v ° I TCB#2, TYPE 2 60"0 ° 4 d " -- st so °u
S °
j TC 3, TYPE' 2 - 4&" FLO SPLITTER d °sq- 0
' S DE L° ON -SSHEET, 5
STA: ° +18.29, 85.23 L a Q � d 3T °1 �,� .d k0
Ef= <
9'g 12" ADDS 0 .4Q% f g i
Q
245 i g 2 ° I ° ° `
TA: '12+4 97 5 215, LP
/ i 1pRM ,35 LF 12"401°0 .51% �
�\ I 33 LF 18 AbS N-12` 1.00% ° dSD
r � \��
° d °
° °d
° °
STCB#5,° TYPE 1 ° d
i
/ STA,: 11+09.25, 51.564 L 6' ° d
° 26 2n �ADN 12 0 4. .
C`)
q @ 050% °
°
2 / -
�I
LL °
i STCB#4,`T4E°
a°
PE
-STA:+48°72,- SOi�+77&&' 19.16' L
38 LF 12
r:
STCB#9. TYPE 1 I
__--246" J /``�' i 14' STA: 14+77.88, 19.16' R I
D-PROFILE
104100 /r / 11+00 " - �a- - , c- 12+80 t
- _ �' �,r �c' o•
« - --- ---- - - _ - -- y r
I
G_
ss
SD- D SD -SD -SD- �
�SD�t, i-, � �H '. �c�---
-�V G G
s \
5i -n3-`r>SD-...i �Ts ....�SD- -^ S(r.,. SPr- {sD -_ .,f�•:,.. } _ ,-rs"�33 ,..
°
V
{
245
--i - - -
- � SD - SD - - 5G
OSD i -- L\ I cNa
_ I
so,�
O
NOTES
1. STATION AND OFFSET INFORMATION BASED ON
CENTERLINE OF 351ST.
2. SEE STORM PROFILES ON SHEETS 5, 6, AND 7.
PLANT 2 RELOCATION
STORM PLAN
Know what's below.
Call before you dig.
Structure Table
Structure Name
Structure Details
AREA DRAIN #1
I.E.
RIM = 253.93
6" (NE) = 250.92
RIM = 252.05
STCB#1
I.E. 18" (SW) = 242.90
I.E. 18" (NW) = 242.90
RIM = 252.39
I.E.
12" (E) = 244.80
I.E.
12" (S) = 244.80
STCB#2
I.E.
12" (N) = 244.80
I.E.
18" (W) = 245.24
I.E.
8" (NW) = 244.80
RIM = 251.89
STCB#3
I.E.
18" (E) = 244.91
I.E.
18" (N) = 244.91
RIM = 252.23
STCB#4
I.E.
12" (W) = 245.99
I.E.
12" (N) = 245.99
STCB#5
RIM = 249.90
I.E.
12" (E) = 246.70
RIM = 250.04
I.E.
12" (S) = 245.66
STCB#6
I.E.
12" (NE) = 245.66
I.E.
12" (W) = 245.66
RIM = 249.40
STCB#7
I.E.
12" (SW) = 246.00
RIM = 248.21
STCB#8
I.E.
12" (SE) = 245.84
I.E.
12" (N) = 245.84
STCB#9
RIM = 248.21
I.E.
12" (NW) = 246.03
RIM = 252.00
I.E.
12" (NW) = 246.11
STCB#10
I.E.
12" (E) = 246.11
I.E.
12" (W) = 246.11
I.E.
12" (S) = 246.11
STCB#it
RIM = 249.76
I.E.
12" (E) = 246.50
RIM = 253.21
STCB#12
I.E.
6" (SW) = 250.50
I.E.
12" (W) = 250.00
RIM = 251.14
STCB#13
I.E.
12" (NE) = 247.50
I.E.
12" (SE) = 247.50
RIM = 252.96
STCB#14
I.E.
12" (E) = 249.50
I.E.
12" (SW) = 249.50
RIM = 254.47
STCB#15
I.E.
12" (E) = 250.82
I.E.
12" (W) = 250.82
RIM = 254.47
STCB#16
I.E.
12" (W) = 251.25
NOTE:
THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER
APPROVAL DATE. THE CITY WILL NOT BE
RESPONSIBLE FOR ERRORS AND/OR OMISSIONS
ON THESE PLANS.
FIELD CONDITIONS MAY DICTATE CHANGES TO
THESE PLANS AS DETERMINED BY THE CITY
ENGINEER.
PERMIT NO. XX-XXXXXX-XX
APPROVED
DATE
258 - - - -
EXISTING GROUND \
ROPOSED GRADE
R&YA
7 LF 8 LF 8" ADS N-12 0 1.00%
8" ADS N-12
0 28.14%!
PRESETTLING VAULT
SEE DETAIL
ON SHEET 7 j
I.E. 18" (S) = 242.50I
I.E. 8" (E) = 242.50
I.E. 18" (N) = 243.501
240
STA:
RI
12+48.70 97;59' L
= 252.39
I,
12"
(E) = 244j80
I.E.
12"
(S) = 244,80
I.E)
12"
(N) = 24480
I.E.
18"
(W) = 245.24
I.E.I 8"
(NW) = 244.80
234
215 LF 12" ADS N-12 0 9.40%
PLANT 2 RELOCATION
STORM PROFILES AND DETAILS
A PORTION OF THE SOUTH 1/2 OF THE 8 E 1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M.,
CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON
35 LF
12" D.I.
0 0.51%
3TC8#6, TYPE 2 - 48*0-
STA: 14+98.51 48.00' L
RIM = 250.04
I.E. 12" ($) = 245.66
I.E. 12" (NE) = 245.66
LE 12'- (W)-= 245,66-- -
STCB#8, TYPE
STA: 14+77.88 19.16'
RIM = 248..
I.E. 12 (SE) = 245.f
I.E. 12" (N) = 245.E
I
I
I
I
258 258
EXISTING GROUND
PROPOSED GRADE -
252252
�I 7LF18"ADS N-12005 -- -
24 LF 18 ADS N 12 0j10.04%
- - 246 246:
38 LF INFILTRATION VAI;ILT
12 D.I.SEE DETAIL ON SHEET 7
0 0.50 I.E. 18" (E) = 242I85
W/ HEAVY; TRAFFIC LID/TOP
PER DETAIL ON SHEET 8
RIM = 252�26 (CENTER OF
I.E. 8" IN (E) = 244.721
I.E. >3 out
" (w) = 244.47
1
LID)
nz _
0
. _ -
S 'ORM 1
- - ---
'PIPE C ENTER NE
--
-
SCALE' =
1" 30' H'
I
z
�,
0
1"' = 3' V
wa
I
228
n 1l"
U)
O
� �
Op m'2
m
� "pip
m
c) O
in
f f
�
N
n
N N
N
N
nn N
N
N
N M
n�i N
M M
N
M
N
M n
N
M
,�.; N
,�.i N
Wi
N
t O
240
STC131, TYPE 1
STA: 14+77.88 19.16' R
RIM = 248.21
I.E. 12P (NW) = 246.03
234
228
LF
18" ADS 12
0 0.'S6%
240 -
STCB#1, TYPE 2 '- 48"0
-
STA: 12+38.05 188.91' L
RIM=',252.05
I.E. 18" (SW)=i242.90
I.E. 18" (NW)='242.90
6 LF
18" ADS N-12
0 1.00%
2341 -
'o
Q
0
Z
;N
o
a
z
�
a
w
1
i
PRESETILING VAULT
SEE DETAIL ON SHEET
I.E. 18' (S) = 242.50
I.E. 8" (E) = 242.50
-Imo.-18", (N)-=--243,50-'';--
117
- .. 1- - -- -1258
- 246
33 LF
8" ADS N-12
0 1.00%'
- - - -', 240
StCB#2, TYPE 2 - 60"0
FLOW SPUTTER
PER DETAIL ON SHEET 5
STA: 12+48.70 97.59' L
RIM = 252.39
I.E. 12" (E) = 244,80
BIOPOD BIOFILTER I.E. 12" (S) = 244.80
MODEL 13PU461B I.E. 12" (N) = 244.80
SEE DETAIL ;ON SHEET 8 I.E. 18" (W) = 245.24
_ ->- - -
RE 18 2(S)28 (CENTER OF VAULT)I.E. 8" (NW) = 244.80
234
I.E. 18" (N) = 242.96 STCB#3, TYRE 2 48"0
STA: 12+1829 85.23' L
RIM - 251.89
STORM 2 I.E. 18" (E) '= 244I91
_ n - I.E. 18" (N) = 24491
PIPE CENTERLINE
SCALE 1 - 30 H
1"=3'V
O
_
O
N N
N N
N N
N N
N N
N04
N
228
LO
N
TO OIL
WATER
SEPARATOR` �
REMOVABLE
DOWNTURNED
ELBOW
TO BYPASS '✓
CONVEYANCE
- II
CB, TYPE 2-60"0
STEPS/LADDER
i
✓ \ i i 12„
24" SOLID
LOCKING LID
I 2a
FROM PH
CONTROL
_ SYSTEM
PLAN VIEW
RIM EL= 252.39
7244 LE. 12" (E) = 244 80
I.E. 8" (NW) = 244.80
I.E. 18" (SW) = 245.24
I.E. 12" (S,N) = 244.80
242 -
PROFILE VIEW
S ■ CB#2
OIL CONTROL BYPASS / FLOW SPUTTER DETAIL
SCALE: i" = I'
Know what's below.
Call before you dig.
NOTE:
THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER
APPROVAL DATE. THE CITY WILL NOT BE
RESPONSIBLE FOR ERRORS AND/OR OMISSIONS
ON THESE PLANS.
FIELD CONDITIONS MAY DICTATE CHANGES TO
THESE PLANS AS DETERMINED BY THE CITY
ENGINEER.
PERMIT NO. XX-XXXXXX-XX
APPROVED
DATE
258
252
246
168 LF 121 ADS N-12
240
STCB#2,
FLOW SPUTTER
PER DETAIL
TYPE 2 - 60-0
-
ON SHEET 5
STA: 17+48.70
97.59' IIL
RIM =
252.39
I.E. 120
(E) = 244.80
I.E. 12"
(S) = 244.80 1 o
W
1g1
I.E.
NW = 244801
()
z
_
I ~
5R
O
234
LL'
a
258
EXISTING
PROPOSED GRADE
252I
i
258
-- - ---- 252
PLANT 2 RELOCATION
STORM PROFILES
A PORTION OF THE SOUTH 112 OF THE S.E.114 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M.,
CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON
F 258 258 - -- -- �- �- I
EXISTING GROUND
PROPOSED GRADE
188 LF 12" ADS N-12
STCB#10, - E 2 - 48"0
STA: 12+59.83 265.27' L
RIM = 252.00
I.E. 12" (NW) '= 246.11
I.E. 12" (E) _ 246.11_
- - I.E. 12" (W) = 246.11
I.E. 12" (S) 246.11
STORM 3
PIPE CENTERLINE
SCALE 1" = 30' �H
1"=3'V
258
EXISTING GROUND
252 PROPOSED GRADE
I
246
78 LF 1?" ADS N-12 ®0.50%
246
246ffSTC1315TYPE
14I
STCB#11, TY E 1
STA: 11+86.;82 238.11' L
STA: 11+09.25 51.56'
-
12" (E) 76 246.50 --
RE 2
RIM = 249.90 -
STC13#10, TYPE - 48"0
I.E. 12' (E) = 246.70
STA: 12+59.831� 265.27' L
Rk = 252.00
240
--I.E. 12"- (NW� =---246.11-
- -1240
240
I.E. 12" (E) 246.11
I.E. 12" (W) '= 246.11
I.E. 12" (S1 = 246.11
STORM 5
----
PIPE CENTERLINE
--
PROPOSED GRADE
SCALE 1" = 30'IIH
z
EXISTING GROUND
1" = 3' V
L
23 1
234
234 w a
o�
o� v
a ^
oo
N
C-4
N
NN NN
N
N N
O
NN
O
N N N
LF 12"--ADS
PROPOSEDGRADE
252
252
III
® 1
D N-12LJ
-
--
91 LF 12"
--
52 � N,12
I
12" P�3 65 0
TCB#1 ,TYPE 1
246
246 63
STA:. 12+54.52.344.48__L
STCB112, TYPE�
1L
'�
12" 21%
I
„
RE ? 2O96
STA:
15+41.08 174.58 L
I.E. �;2" (SW)=249.56 249.50
RIM = 253.21
I.E.
6" (SW) = 250.50
LJ
ST0113, TYPE 1
- I.E.
12"-(W) = 25D.00
_ _
STA: 12+16.14 �310.02'
L
RIM = 25114 1 - -
- -
I.E. 12" (NE) = 247.50
I.E. 12" (SE) = 47.50
StCB#10, TYPE 21- 48"0
i
STORM' 4
240
240 STA: 12+59.83 265265.27'L
R1M = 2(N.00
z o o
-
I.E. 12" (NW) = 24fi.11
0
�
PIPE CENTERLINE
I.E. 12" (E) = 246.11
cD
SCALE 1" _ 30' H
I.E. 12" (W) = 246.11
CL
1" = 3' V
I.E. 12" (S) = 246.11
0
a
237
w
CD
rn `_�� .r
��uN-J .-
QN �Nco
N NN
�M ��
NNNN N
NN NN
NN N
234
258
���----
���r�-r,��� 252
246
-
m
N Ci N
Ln N F Lo Ln
N N N tom, N � 1 N
258
EXISTING
PROPOSED GRADE
258
252 252
I
246
3TCB#6, TYPE 2 - 4810
STA:
14+98.51
48.00' '!L
RIM
= 250.04
I.E.
12" (S) =
245.66
I.E.
12" (NE)
= 245.66
I.E.
12" (W)
= 24566
35
246
C13#7, TYPE 1
A: 15+33.74 48.00' L
4 = 249.40
12" (SW) = 246.00
" ADS N-12 ® 0.977
240
_ STORM 71
PIP1 CENTERL NE
SCALE 1 " = 30' 'H 1
PROPOSED GRADE 1" = 3' V
EXISTING GROUND
234I 234
N N N
86 LF 12" AOS N-12
STCBj15, TYPE 1
STA: 14+95.57 311.99' L
RIM 254.47 1
I.E. 12" (E) = 250.42
--- LE. 12" (W)=-25082 _-
CN
N
252
I
C8116, TYPE 1
A: 15+72.88 274.55' L
4 = 254.47
. 12" (W) = 251.25
246
240
237
Know what's below.
Call before you dig.
NOTE:
THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER
APPROVAL DATE. THE CITY WILL NOT BE
RESPONSIBLE FOR ERRORS AND/OR OMISSIONS
ON THESE PLANS.
FIELD CONDITIONS MAY DICTATE CHANGES TO
THESE PLANS AS DETERMINED BY THE CITY
ENGINEER.
PERMIT NO. XX-XXXXXX-XX
APPROVED
DATE
256
252
248
244
240
GRAPHIC SCALE
20 0 10 20 40
( IN FEET )
1 inch = 20 ft.
VERTICAL DATUM: NGVD 29
EXISTING G
OUND
/
I
PROPOSED GRADE
d
d
-i
INFILTRATION VAULT
SEE
DETAIL, THIS
SHEET
SECTION A A
SCALE: 1" = 20' H
1"-2'V
256 256
252 252
248 248
244 244
240 240
PLANT 2 RELOCATION
STORM VAULT DETAILS
A PORTION OF THE SOUTH 1/2 OF THE S.E.1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANG 4 EAST, W.M.,
CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON EL = 242.00
VAULT BOTTOM
EXISTING GROUND
—
PR
POSED GRADE
a
d
INFILTRATION
VAULT
SEE
ETAIL, THIS SH
ET
I
SECTION B-B
SCALE. 1" = 20' H
1"-2'V
256
i
EXISTING
GROUND
256 - -
252
248
,PROPOSED
,GRADE
252
244
244
Fl%f1
256 256
252 252
248 248
244 244
240 240
236 236
240 234 --1--'234
SECTION C-C
SCALE: 1" = 20' H
1"-2'V
234
SECTION D-D
SCALE: 1" = 20' H
1"=2'V
EL 24
VAULT BOTTOM
TOP INSIDE VAULT
ELEVATION = 248.00
VAULT BOTTOM ELEVATION
AT WALL CORNER = 242.00
ACCESS MANHOLE W/ LADDER SUPPORT WALL (TYP)
ROUND SOLID COVER MARKED (SEE STRUCTURAL PLANS FOR 1
'BRAIN" WITH LOCKING BOLTS (TYP.) EXACT DIMENSIONS AND LOCATION) I
h
0
0
148'
LVAULT WALL OPENING (TYP)
(SEE STRUCTURAL PLANS FOR EXACT
DIMENSIONS AND LOCATION)
EL = 237.50
VAULT FLOOR
256 EL = 23ZI
VAULT FLOOR //
18"0 INLET<"
EL = 23Z50
VAULT FLOOR
248
244
240
236
234
TOP INSIDE VAULT
ELEVATION = 246.00
18"0 INLET
VAULT BOTTOM ELEVATION
AT WALL CORNER = 237.:
ACCESS MANHOLE W/ LADDER U
W/ ROUND SOLID COVER MARKED INLET
"DRAIN" WITH LOCKING BOLTS (TYP.)
1J
FREEBOARD
18"0
INLET
SCALE: 1" = 20' H
1"=5'V
ACCESS MANHOLE W/ LADDER
W/ ROUND SOLID COVER MARKED EL = 237.50
"DRAIN" WITH LOCKING BOLTS (TYP.) VAULT FLOOR
SLOPE
V VALLEY LINE V aTroM
V SLOPE oeC
63' BOTIOM
V
7n
18"0
:30uTLET
EL = 237.12
VAULT FLOOR
8.0 EL = 237.50
INLET VAULT FLOOR
18"0 OUTLET
SEDIMENT STORAGE
ELEVATION = 238.50
PRESETTLING VAULT DETAIL
SCALE: 1" = 20' H
NOTES:
1. ALL METAL PARTS MUST BE CORROSION RESISTANT. STEEL PARTS
MUST BE GLAVANIZED AND ASPHALT COATED (TREATMENT 1 OR
BETTER).
2. PROVIDE WATER STOP AT ALL CAST -IN -PLACE CONSTRUCTION
JOINTS. PRECAST VAULTS SHALL HAVE APPROVED RUBBER GASKET
SYSTEM.
3. ALL DIMENSIONS SHOWN ARE INTERIOR DIMENSIONS NEEDED FOR
VAULT OPERATION. REFER TO STRUCTURAL DESIGN PLANS.
4. THE VAULT SHALL NOT BE USED FOR STORMWATER
DETENTION/RETENTION UNTIL THE WALLS HAVE BEEN BACKFlLLED TO
THE FINISHED GRADE.
5. SIZES AND LOCATIONS OF ACCESSES AS SHOWN. ALL VAULT AREAS
MUST BE WITHIN 50 FEET OF AN ACCESS POINT.
6. ENTRANCE TO CONFINED SPACE WILL BE CLEARLY MARKED AS
REQUIRED BY OSHA. THIS MAY BE ACCOMPLISHED BY HANGING A
REMOVABLE SIGN IN THE ACCESS RISERS JUST UNDER ACCESS
GRATE.
Z VAULTS ARE NOT ALLOWED IN FILL SLOPES WITHOUT A
GEOTECHNICAL STUDY FOR STABILITY.
8. REFER TO STRUCTURAL PLANS FOR LOADING REQUIREMENTS AND
DESIGN CRITERIA.
9. FOR RAISED OPENINGS WHERE THE DEPTH FROM THE IRON COVER TO
THE TOP OF THE VAULT EXCEEDS 24", AN ACCESS STRUCTURE
EQUIVALENT TO A TYPE 2 CATCH BASIN OR TYPE 1 MANHOLE SHALL
BE USED.
10. VAULT STRUCTURAL PLANS AND SPECIFICATIONS TO BE REVIEWED
AND APPROVED UNDER A SEPARATE BUILDING PERMIT. VAULT SHALL
MEET H2O STRUCTURAL LOAD REQUIREMENTS.
EL = 242.00
VAULT BOTTOM
EL = 242.00
VAS ULT BOTTOM
DESIGN WATER SURFACE
ELEVATION = 247.00
Imp
Know what's below.
Call before you dig.
NOTE:
THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER
APPROVAL DATE. THE CITY WILL NOT BE
RESPONSIBLE FOR ERRORS AND/OR OMISSIONS
ON THESE PLANS.
FIELD CONDITIONS MAY DICTATE CHANGES TO
THESE PLANS AS DETERMINED BY THE CITY
ENGINEER.
PERMIT NO. XX—XXXXXX—XX
APPROVED
DATE
816-2-CPS
Projected Coalescing Plate Area = 2368 Sq.Ft.
-Design Flow Rate = 560 GPM (see back page)
Maximum Process Flow - 1,508 GPM
TOP
No. 816-T-CPS Full 18D' Open
{(4) - 8 Tun Lift Anchors
14,970 Its. Typical)
Suitable for use in oft -street locations , 14,
where not subjected to high,danslty trofflc '1 Full 180' Open
*. .-'� p rNo. 57-6-T-2-332P
Risers as Required-�- y.� r 1,645 Its.
10" PVC OUTLET PIPE
w/Sompsng Tea
BASE ASSEMBLY
No. 816-B-CPS --
34,325 Ibs.
8 Ton Lift Anchors
(2 Each End in Floor)
OPTIONAL TOP - HEAVY TRAFFIC \
No. 816-T-CPS-HD
17.,370 lbs. (2) - No. 24 x 4 Castings
%(25' Grdde Ricers x 4 Co
No. 42 x 4 Costing
r42" Grade Risers Awiloble
Note: Designed for 0 to 5'-0m of Cover
/ys 816-2-CPS
iwri PYdGi:-Ci5110 ® Fib Nwrre:o20-aisc 2
PO Box 323, Wilsonville, Oregon 97070-0323 Issue Date: 2018
Tel: (503) 682-28" Fax: (503) 682-2657 oid"slleprecesLCoro/W
11.0
816-2-CPS
- No. 23-2436P
I lbs. Each)
t rTz n�'Q ...
Retaining Baffle
Sediment Weir
10" PVC INLET PIPE
wjTee 8'-8-
Notes:
- 816-CPS is awiloble set up for future installation
of coalescing media and designated as 816-CPS-R.
Customer is responsible far supplying crane to set
and assemble moult.
816-2-CPS
OIL / WATER SEPARATOR
COALESCING - 560 GPM
Projected Coalescing Plate Area - 2.368 Sq.FI.
•Design Flow Rate - 560 GPM
Maximum Process now - 1.60a GPM
i6-1
No. 2-332P
Spring d Flats
CMwnlsmd ock;nd Data y_e' +-- 4'-8" ----- 2'-e' (2) - No. 2438P
Doom w/Lodc;no Latch I ( wAoc Diamond Plata Doors
— — — — — — /LockIngng Latch
i
A I I A h P.
I e
(4) - a -Ton
-� 2-2' bin >Ychms �— 8 -5k" 2'-2-
2'-2" VIEW Flow Line
OI Retaining Baffle
2'-0• x 3'-0" Blackout Hood -Gown 10" PVC INLET PIPE
(Typical) for Coalescing Meow w/T++
10' PVC OUTLET PIPE 4'-2" x 6'-6" OPTIONAL TOPS:
w/Sampth, Toe BI4cIfWt 2'-9" and S-g" Heights
BUIII Raman Sealant Rlse's ae ?'
RmquSrmd �
.d - . a a, ui
0
E Sediment Wear �ar
rc
N �
p I a
1 1
N
Coalescing Mmdfo
E-Ton Lift Anchor {�,
(2 Each End) ;,_ 1a
SECTION AA
"DESIGN
100%
Bask Gesin Information: -
FLOW
EFFLUENT
COLLECTED
Influent Choracterka
- 04 Specific Cranky - 0.88
RATE
QUALITY
512E
- Opwatng Temperature - 50'
10 ppm
60 Micron
- influent Oil Concentration = 100 Ppm
560 GPM
- Mean Cs Droplet Sim - 130 Microns
Notes:
- ,033 ft/min, Critical OR Droplet Predicted IN" Rate
- Static Water Depth - 4•-G'
- Prior to "Startup" of system, fill with clean water
-Basic Design Information 0+r Washington
to bottom of outlet Pip+. For best results, fill to flow line.
Stott Department of Ecology User to Adpast
- Follow Regular Inspection. Clwmng, At Molntanance
Estimates far Variations in Real Conditions.
Schedule (Saw Clean Out d: MOlntanance)L
—� 816-2-CPS 816-2-CPS
Prtiecaste FiWX81; 02D 16CPsz OIL !WATER SEPARATOR
PO Box 323• Wilsonville. Oregon 9707OM23 Issue Date 2018 COALESCING -560 GPM
.. _.
Tel: (503) 682-2844 Fax. (503) 682.2657 OldeaedepreCast.com/wilsonvilie
PLANT 2 RELOCATION
STORM NOTES AND DETAILS
A PORTION OF THE SOUTH 1/2 OF THE S.E. 1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M.,
CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON
i--------L i
I I
INLET WINDOW
— — — — — — — — — — — i
INLET - } -k4
2'-2.126.1 DROP
RECOMMENDED, W MIN.
OPTIONAL DRAIN
DOWN DEVICE
Y-10"
LEFT END VIEW
018" RCP MAX. INLET
ALTERNATE INLET LOCATION —\
8' 0"
ALTERNATE OUTLET LOCATION -/
018" RCP MAX. OUTLET
2X 024" BOLTED & GASKETED ACCESS COVERS,
FIELD POURED CONCRETE COLLAR REQUIRED,
BY OTHERS.
'MIN
MAX
0"
WALL
WEIR
DIVIDER WALL
PLAN VIEW
2X 036" BOLTED & GASKETED ACCESS COVERS.
FIELD POURED CONCRETE COLLAR REQUIRED.
BY OTHERS.
ELEVATION VIEW
T
DESIGN LOADINGS;
A AASHTO HS4044 (WITH IMPACT)
B. DESIGN SOIL COVER: T-V MAXIMUM
C. ASSUMED WATER TABLE: BELOW BASE OF
PRECAST
(ENGINEER -OF -(RECORD TO CONFIRM SITE
WATER TABLE ELEVATION)
0, LATERAL EARTH PRESSURE: 45 PCP
(DRAINED)
E. LATERAL LIVE LOAD SURCHARGE: 80 PSF
(APPLIED TO 8'-G' BELOW GRADE)
F. NO LATERAL SURCHARGE FROM ADJACENT
BUILDINGS, WALLS, PIERS, OR FOUNDATIONS.
2.
CONCRETE 28-DAY MINIMUM COMPRESSIVE
STRENGTH: S,000 PSI MINIMUM.
S
REINFORCING: REILM, ASTM Ae157A706. GRADE 60
4.
CEMENT: ASTM C150
S.
REQUIRED ALLOWABLE SOIL BEARING CAPACITY:
2,500 PSF
6,
REFERENCE STANDARD:
A. ASTM C890
8. AWMC9t3
C AC131S14
7.
THIS STRUCTURE IS DESIGNED TO THE
PARAMETERS NOTED HEREIN.
ENGINEER -OF -RECORD SHALL VERIFY FY THAT
NOTED PARAMETERS MEET OR EXCEED PROJECT
REQUIREMENTS. IF DESIGN PARAMETERS ARE
INCORRECT, REVIEWING ENGINEER)AUTHORITY
SHALL NOTIFY OLDCASTLE INFRASTRUCTURE UPON
REVIEW,
8,
INLET AND OUTLET HOLES WILL BE FACTORY
COREDICAST PER PLANS AND CUSTOMER
REQUIREMENTS. INLET AND OUTLET LOCATIONS
CAN BE MIRRORED.
9,
CONTRACTOR RESPONSIBLE TO VERIFY ALI. SIZES.
LOCATIONS. AND ELEVATIONS OF OPENINGS.
10.
CONTRACTOR RESPONSIBLE TO ENSURE
ADEQUATE BEARING SURFACE IS PROVIDED (LE.
COMPACTED AM LEVEL PER PROJECT
SPECIFICATIONS).
it.
SECTION HEIGHTS, SLABM'ALL THICKNESSES, AND
KEYWAYS ARE SUBJECT TO CHANGE AS REOUiRED
FOR SITE REQUIREMENTS AND/OR DUE TO
PRODUCT AVAILABILITY AND PRODUCTION FACILITY
-`-RIM
CONSTRAINTS.
4" MIN TO 12.
MAXIMUM PICK WEIGHTS':
A TOP = XX.XXX LBS
5' MAX COVER
B. BASE: XX,XXX LBS"
(SEE NOTE 1.B)
C COMBINED INSIGHT OF BASE INCLUDES
BYPASS WEIR. DIVIDER WALL. ROCK 6 MEDIA)
13.
INTERNALS SHALL CONSIST OF UNDERDRAIN
PIPE, ROCK, STORMIAX- MEDIA. MULCH, DIVIDER
WALL, BYPASS WEIR AND OPTIONAL DRAIN DOWN.
ENERGY DISSIPATION
STONE
2"
MEDIA
L-6" DRAIN ROCK
UNDERDRAIN PIPE
E;
Know what's below.
Call before you dig.
NOTE:
THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER
APPROVAL DATE. THE CITY WILL NOT BE
RESPONSIBLE FOR ERRORS AND/OR OMISSIONS
ON THESE PLANS.
FIELD CONDITIONS MAY DICTATE CHANGES TO
THESE PLANS AS DETERMINED BY THE CITY
ENGINEER.
PERMIT NO. XX—XXXXXX—XX
APPROVED
DATE
GRAPHIC SCALE
30 0 15 30 60
( IN FEET )
1 inch = 30 ft.
VERTICAL DATUM: NGVD 29
4 LF 12" ADS N-12 ® 10.007o
© STCB#19, TYPE 2 - 4800
W/ SOLID LOCKING LID
STA: 10+80.78, 27.55' L
SAWCUT AND SEAL EDGE
15 STCB#18, TYPE 1
STA: 10+91.20, 23.3 L
46 LF 12" ADS N-12 ® 0%--�,
15 STCB#17 1
STA: 10+72.65 19. ' R
STA: 10+00.00 10 0
q INTERSECTION
PACIFIC HWY S./
S. 351ST STREET
SD-SD-SD-
258
252
246
GRADE BREA
240
46 LF
234
228
221
PLANT 2 RELOCATION
S. 351ST ST. PRIVATE ROAD PLAN AND PROFILE
A PORTION OF THE SOUTH 1/2 OF THE S.Ea 1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M.,
CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON
aI I �a ...°'; ^d°a a ` a l a� a_°'/e a° l °•;) °�e ° /l a ° e I d a s I
CSd
°a , dd. - ° e \°dl • a ed e ° d a-4I /q d
d d a d a
e
dA. e e a
a °
e.° SD --P SD
d dae
° e e sda SD• : %Sa D .�s` 8 _ • C�a njd'!'a-- -
�L
/
e a,
9 a a ° d n
e e
d a a
d - ° a e. ° d
a ed
e
♦ Iia
Y,e�'
-' STA: °11+0 .9.. °55d
.00 i.) a a tly/
°. Ida e, ° •e a i a d d. _'I'•• 0/SD 55/.
rF�CENPER _� ° � a e, a ° e y-' S0ii5s/ •.
' V ° d
-a \d d
-
fy'
`
fi3+-00-
S88 32 22'E 329 04
_ sic
N. S _. S
_ SS _ N 55 S
'
SD SD oJ-.-..SD= L
s
_ .-TT'
SD SD
_
-
4)_ O
STA: 15+3✓ 42, 20.50'(L) (BACK OF CURB)
INSTALL 451 WIDE COMMERCIAL
DRIVEWAY APPROACH PER
CITY OF FEDERAL WAY STD DWG NO. 3-6A
STA: 15+68.42
END FULL ROAD IMPROVEMENTS
(PAVING, CURB, GUTTER, AND SIDEWALK)
VJ W
_.--. SD_
SD SD -
� 2�132 i s I I
N o ' STCB#8, TYPE 110
8 STA: 14+77.88,119.16' L
38 LF 12" D.I. ® 0.50%
I
°'gam STCB#9, TYPE 1 15 1
° ®p STA: 14+77.88, 19,16' R
o I
4 STA: 14+28.29, 20.50'(R) (BACK OF CURB)
9 INSTALL 30' WIDE COMMERCIAL DRIVEWAY
APPROACH PER CITY OF FEDERAL WAY STD DWG NO. 3-6A
I
I
._ ...
..,,._
--
_- -
-
THIGH
PT. STA
13+14.45
L
W PT. STA 1�+77.88
LOU
HIGH PT ELEV
= 250.73
LOW
PT ELEV =
248.61
0
PW STA = 12+85.00
PVI STA = 14+60.00
0
PVI ELEV=1251.69
PA ELEV = 248.25
A.D. = -6.97%
A.D. = 2.96%
z o
-
135' VC
K =-_37.1
g
o
_
- -
110' VC
- -
z
Ln
+
M O
L L6
M
DWAY
o
DWAY
N
v
0
o w
N X
W
o
+ N
+�
.
+
to
O
00
N
*
toJ
J",^��
Z Q O
II =
?�
W
252
�i--_
�,
"-
.-
_
LU
LOW PT. STA = 10+72.65
v
> m
ro
'1.96'$' - -
m
I
>
W
w
LOW PT ELEV = 241.69
_ -
PW STA '= 10+82.64
E
ISTAG GROUNDro
I II
I
- - -
- - - - -
- -
- -
- •�090 '-
- -
- _
PVI ELEV = 241.56--
Z
A.D. = 6.001.
PROPOSE
GRADE
K3
i
I
it
R/W ' VC
III
I I
III
i�
III(I�
II II
IIII
co
-'
j-r
III
III
II II
IIII
246
III
I I
5opq.
III
�
� � � N
III
III
i (�
IIII
_ �l
���
III
III
III
I
N"
m_ � w
III
I
I I
IIII
m�
III
�
I I
IIII
III
1Os
STCB#9, TYP
1
I I
BIOPOD BIOFILTER Q
I
STA = 1(j+48.96
MODEL BPU -4618
I
I I
STA:
14+77.88 19.16"
R
I I I
ELEV =
! 241.90
I
I' I
I ( I
I.E. 12" (E) '- 237.50
III
I
II
II
I.E. 12"
RIM = 24821
(NW) = 246.
I I
I
III
MATCH ;
XISTING
_.LE. -12" (W) _ 237.00-
24C
IIII
I I I I
IIII
I
I
� I�
III
38 IF
I
I1
III
12" D'',I.
I
I
II II
EXISTING
STORM
11
II I
00.5
I
I
II II
_-�
2" ADS N
12 0 0.50%
II II
I II II
STCB#18,
TYPE 10
--"- _
-------
I
II I
I�
STA- _i
91.20 -23.30-L
RIM = 242.30
_ _ _
- -
_ - - -
- tE:
)-=-23387
I
III
----
-
IIIIII
23ti
I
I.E. 12" (NW)
= 237.87
-----
---
_---
s TYP
STCB#8,
i Ii I
II
14+77.88 19.16'
IIII
I IIII
3 LF 1
ADS N-12 0
2.32%
----------
------
1
II
STA:
L
11
III
RIM = 24821
1
II II
-------------
4 LF 12"
DS N-12 ®1000%
II I
I.E.
2" SE = 245.84
12" N 245.84
it II
STCB 9, TYPE
2- 46 "o
EXISTING SANITARY
SEWER
I.E.
I I
I I
I
W/ SOLID LOCKING
LID 1s
I
I
I�
27.55' L
--I F I
-------
J
STA 10+80.7
RIM-"2�2�4-�
I
S. -
----
---------o
iu ---
U U
I E 12 SE
236.60 -
--
-----
----
--- _
STA:10+00
_ _�a�! .1
_.
TO S A:16f0700
221
I.E.12 (N;
- ------
----
=o
I
L I L _
----
sra#1i.
TYPE i
s
STA:
R
SCALE: 1" = 30$ FI
z
10+72.65 19.16'
RIM
= 241.28
1" 3' V
I.E.:
12" (NE) = 238.10
57<
a
22:
pOq
0)
N^
a} d-O
M V7
M
�. W
M �-4,
M rn�
m�
I� 00 M
r7� ,p^ .-.^y.
�}00
N rn
M
N n00
�O
N ,I]O
no cD�
LO coN
�
��
N
N
V'
N^
V'
�"�
�-
i'
d• d-
�[]
.N� v+
tp
d-
N
� �F'
O)
O
N
.4. u'] L ,n L N
p O
1
aj m
6 Oi
W m
m
Oi
N
m
N
Of Oi
N
m
d-
N
N
N
N N
N N
N N
N N
N N
N N
N N
N N N N N
N N
N N
N N
N N
N N
N
N
N
N
10+00 10+20
10+80 11+40 12+00 12+60 13+20 13+80 14+40 15+00 15+60
16+07.27
ATM NOTES
10 EXISTING UTILITY POLE TO REMAIN, PROTECT DURING CONSTRUCTION
Q EXISTING CATCH BASIN TO REMAIN, PROTECT DURING CONSTRUCTION
AND ADJUST TO FINISH GRADE AS NECESSARY
Q3 EXISTING SANITARY SEWER TO REMAIN, PROTECT DURING CONSTRUCTION
AND ADJUST TO FINISH GRADE AS NECESSARY. CONTRACTOR TO
COORDINATE WITH LAKEHAVEN WATER AND SEWER DISTRICT AS
NECESSARY
® EXISTING WATER VALVE TO REMAIN, PROTECT DURING CONSTRUCTION
AND ADJUST TO FINISH GRADE AS NECESSARY. CONTRACTOR TO
COORDINATE WITH LAKEHAVEN WATER AND SEWER DISTRICT AS
NECESSARY
0 EXISTING GAS VALVE TO REMAIN, PROTECT DURING CONSTRUCTION AND
ADJUST TO FINISH GRADE AS NECESSARY. CONTRACTOR TO
COORDINATE WITH PUGET SOUND ENERGY AS NECESSARY.
© EXISTING WATER METER TO REMAIN, PROTECT DURING CONSTRUCTION.
CONTRACTOR TO COORDINATE WITH LAKEHAVEN WATER AND SEWER
DISTRICT AS NECESSARY
42 EXISTING UTILITY POLE TO BE RELOCATED, CONTRACTOR TO
COORDINATE WITH PUGET SOUND ENERGY AS NECESSARY
® EXISTING FENCE TO REMAIN, PROTECT DURING CONSTRUCTION
09 EXISTING FENCE TO BE RELOCATED, COORDINATE WITH ADJACENT
PROPERTY OWNER AS NECESSARY
10 EXISTING UTILITY VAULT TO REMAIN, PROTECT DURING CONSTRUCTION
AND ADJUST TO FINISH GRADE AS NECESSARY. CONTRACTOR TO
COORDINATE WITH PUGET SOUND ENERGY AS NECESSARY.
11 NEW ASPHALT TO CONNECT TO EXISTING PAVEMENT FOR THE
CROSSINGS COMMERCIAL DEVELOPMENT, COORDINATE WITH ADJACENT
PROPERTY OWNER AS NECESSARY
©SEE GRADING DETAIL ON SHEET 10
Q BIOPOD BIOFILTER
MODEL BPU-461B
RIM = 242.46 (CENTER OF VAULT)
I.E. IN 12" (E) = 237.50
I.E. OUT 12" (W) = 237.00
SEE DETAIL ON SHEET 12
14 INSTALL TYPE III BARRICADE AT THE END OF WALK PER CITY OF
FEDERAL WAY STD DWG NO. 3-15.
Q INSTALL THROUGH -CURB INLET AND BI-DIRECTIONAL VANED GRATE PER
CITY OF FEDERAL WAY STD DWGS 4-8, 4-9, AND 4-10A
16 INSTALL OVER EXISTING STORM PIPE. CONTRACTOR TO VERIFY
LOCATION, INVERT, AND PIPE TYPE PRIOR TO CONSTRUCTION
Know what's below.
Call before you dig.
NOTE:
THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER
APPROVAL DATE. THE CITY WILL NOT BE
RESPONSIBLE FOR ERRORS AND/OR OMISSIONS
ON THESE PLANS.
FIELD CONDITIONS MAY DICTATE CHANGES TO
THESE PLANS AS DETERMINED BY THE CITY
ENGINEER.
PERMIT NO. XX-XXXXXX-XX
APPROVED
DATE
GRAPHIC SCALE
5 0 Z5 5 10
( IN FEET )
1 inch = 5 ft.
VERTICAL DATUM: NGVD 29
0
S. 351ST ST.
/
--4��366T ST.
/
�A ry e
90'---
�f =35.00' /
T
/��L=41.89' ^' 38 dam,
68034'33" / N _, - 241 9 --
4
241.38 0'45
p.45%
a ?AJ
_ 241.89 41.9 9i
/ � a
241 y�IEX
PLANT 2 RELOCATION
351ST PRIVATE ROAD DETAILS
A PORTION OF THE SOUTH 1/2 OF THE S.E.1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M.,
CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON
C
R
4
Know what's below.
NOTE: Call before you dig.
THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER
APPROVAL DATE. THE CITY WILL NOT BE
RESPONSIBLE FOR ERRORS AND/OR OMISSIONS
ON THESE PLANS.
FIELD CONDITIONS MAY DICTATE CHANGES TO
THESE PLANS AS DETERMINED BY THE CITY
ENGINEER.
PERMIT NO. XX—XXXXXX—XX
APPROVED
DATE
L
NEW ENTRANCE
SEE DETAIL AT RI(
i'
G p
d.
p \7",-
46 p I/
� p
p
PLANT 2 RELOCATION
PACIFIC HWY SOUTH IMPROVEMENTS
A PORTION OF THE SOUTH 1/2 OF THE S.E.1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M.,
CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON
GRAPHIC SCALE
20 0 10 20 40
( IN FEET )
1 inch = 20 ft.
VERTICAL DATUM: NGVD 29
PLAN NOTES
Q EXISTING UTILITY POLE TO REMAIN, PROTECT
DURING CONSTRUCTION
Q EXISTING CATCH BASIN TO REMAIN, PROTECT
DURING CONSTRUCTION AND ADJUST TO FINISH
GRADE AS NECESSARY
3Q REMOVE EXISTING DRIVEWAY APPROACH.
REPLACE WITH NEW CURB AND GUTTER PER
CITY OF FEDERAL WAY STD DWG NO 3-4A,
5.5' LANDSCAPE STRIP, AND 8' SIDEWALK,
MATCHING EXISTING.
® SAWCUT MIN f FROM EDGE OF PAVEMENT AND
SEAL EDGE.
5Q EXISTING LIGHT POLE TO BE RELOCATED,
CONTRACTOR TO COORDINATE WITH PUGET
SOUND ENERGY, WSDOT, AND CITY OF
FEDERAL WAY AS NECESSARY
© EXISTING WATER METER TO REMAIN, PROTECT
DURING CONSTRUCTION
3
GRAPHIC SCALE
20 0 10 20 40
( IN FEET )
i inch = 20 ft.
VERTICAL DATUM: NGVD 29
Know what's below.
Call before you dig.
NOTE:
THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER
APPROVAL DATE. THE CITY WILL NOT BE
RESPONSIBLE FOR ERRORS AND/OR OMISSIONS
ON THESE PLANS.
FIELD CONDITIONS MAY DICTATE CHANGES TO
THESE PLANS AS DETERMINED BY THE CITY
ENGINEER.
PERMIT NO. XX—XXXXXX—XX
APPROVED
DATE
CROSS SECTION TYPE R
2 LANES
+ PARKING
I3'i _6' W*1 8' 1 12' 1 12' I 8' 14'*1 6' 13'1
lA Parking
a
40'
66'
MINOR COLLECTOR
0.25' HMA Y2 PG 581-1-22
0.17' CSTC
0.50' CSBC
Parking ! :a ' w
t a
F
LOCAL (RESIDENTIAL)
0.25' HMA X2', PG 58H-22
0.17' CSTC
0.42' CSBC
NOTES:
1) SUBBASE TO BE BANK RUN AS NECESSARY TO STABILIZE PAVEMENT
4 PLANTER STRIP DIMENSION IS MEASURED FROM THE SIDEWALK TO THE FACE OF CURB.
PLANT 2 RELOCATION
ROAD AND STORM DETAILS
A PORTION OF THE SOUTH 1/2 OF THE S.E. 1/4 OF SEC71ON 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M.,
CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON
6"
REV:
PUBLIC COLLECTOR/LOCAL D3-2R
WG. NO.]
012" RCP MAX. INLET
ALTERNATE INLET LOCATION
ALTERNATE OUTLET
012" RCP MAX. OUTLET
2X 018' TRAFFIC RATED CAST IRON COVERS,
FIELD POURED CONCRETE COLLAR REQUIRED,
BY OTHERS.
INLET WINDOW
—
"
5'-1.114' MIN
13'-10'MAX
INLET --Al DIVIDER WALL
2'-8"
2'-2"1261 DROP BYPASS WEIR
RECMENDEDMIN. I I 11
� — — Unt ITI PT
OPTIONAL DRAIN
DOWN DEVICE
LEFT END VIEW
ill I I � DIVIDER WALL
PLAN VIEW
ELEVATION VIEW
036' BOLTED & GASKETED ACCESS COVER,
FIELD POURED CONCRETE COLLAR REQUIRED,
BY OTHERS.
—RIM
4" MIN TO
5' MAX COVER
(SEE NOTE 1.B)
ENERGY DISSIPATION STONE
2•
I MULCH
StormMixTM MEDIA
6" DRAIN ROCK
1. DESIGN LOADINGS:
A. AASHTO HS-2044 (WITH IMPACT)
B. DESIGN SOIL COVER: F-W MAXIMUM
C. ASSUMED WATER TABLE: BELOW BASE OF
PRECAST
(ENGINEER-0E-RECORD TO CONFIRM SITE
WATER TABLE ELEVATION)
D, LATERAL EARTH PRESSURE: 45 PCF
(DRAINED)
E. LATERAL LIVE LOAD SURCHARGE: 60 PSF
(APPLIED TO V-0-BELOW GRADE)
F. NO LATERAL SURCHARGE FROM ADJACENT
BUILDINGS. WALLS, PIERS, OR FOUNDATIONS.
2CONCRETE 28-DAY MINIMUM COMPRESSIVE
STRENGTH: 5.000 PSI MINIMUM.
3, REINFORCING: REBAR, ASTM A6157A706, GRADE 60
4. CEMENT: ASTM C150
5, REQUIRED ALLOWABLE SOIL BEARING CAPACITY:
2.5(XPSF
6, REFERENCE STANDARD'.
A ASTM CS90
S. ASTM C913
C. AC1318-14
T. THIS STRUCTURE IS DESIGNED TO THE
PARAMETERS NOTED HEREIN.
ENGINEER-OF-RECORO SNAIL VERIFY FY THAT
NOTED PARAMETERS MEET OR EXCEED PROJECT
REQUIREMENTS. IF DESIGN PARAMETERS ARE
INCORRECT, REVIEWING ENGINEERIAUTHORITY
SHALL NOTIFY OLDCASTLE INFRASTRUCTURE UPON
REVIEW.
6. INLET AND OUTLET HOLES WILL BE FACTORY
COREDICAST PER PLANS AND CUSTOMER
REQUIREMENTS. INLET AND OUTLET LOCATIONS
CAN BE MIRRORED.
9. CONTRACTOR RESPONSIBLE TO VERIFY ALL SIZES,
LOCATIONS, AND ELEVATIONS OF OPENINGS.
10. CONTRACTOR RESPONSIBLE TO ENSURE
ADEQUATE BEARING SURFACE IS PROVIDED (I.E.
COMPACTED AND LEVEL PER PROJECT
SPECIFICATIONS).
it. SECTION HEIGHTS, SLAWWALL THICKNESSES, AND
KEYWAYS ARE SUBJECT TO CHANGE AS REWIRED
FOR SITE REQUIREMENTS ANDIOR DUE TO
PRODUCT AVAILABILITY AND PRODUCTION FACILITY
CONSTRAINTS.
12. MAXIMUM PICK WEIGHTS:
A. TOP: XX.XXXLBS
B. BASE: XXXXX LSS'
(' COMBINED WEIGHT OF BASE INCLUDES
BYPASS WEIR. DIVIDER WALL. ROCK & MEDIA)
13. INTERNALS SHALL CONSIST OF UNDERORAIN
PIPE. ROCK, STORMMIX- MEDIA. MULCH. DIVIDER
WALL, BYPASS WEIR AND OPTIONAL DRAIN DOWN.
Know what's below.
Call before you dig.
NOTE:
THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER
APPROVAL DATE. THE CITY WILL NOT BE
RESPONSIBLE FOR ERRORS AND/OR OMISSIONS
ON THESE PLANS.
FIELD CONDITIONS MAY DICTATE CHANGES TO
THESE PLANS AS DETERMINED BY THE CITY
ENGINEER.
PERMIT NO. XX—XXXXXX—XX
APPROVED
DATE
GRAPHIC SCALE so PLANT 2 RELOCATION
UTILITY PLAN
ir: P, — IN FEET) A PORTION OF THE SOUTH 1/2 OF THE 8.E.1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M.,
1 inch = 30 ft.
Z VERTICAL DATUM: NGVD 29 CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON
d m q°
a
e a.
ad 4 a'a d a4' d
d d
4 4
44
4 d q
NEW WATER SERVICE / d° ' d a d ; d d d Ja a
CONNECT TO EXISTING METER \�4
° d 4
da ,
CONTRACTOR TO COORDINATE d4 ° d d °
dN/� ° d a d
WITH UTILITY PROVIDER q°a ° d Q
d ° • 4 °d d A.
r
° ° 4. d d
a a da 4 a e. a a 4 a
d a a a d °' a
4.' d°
4
d a
d
° Q
4 a a d °• a a a° a g d
/ 4 d 4 b 4 a d a a d° °
a
e d 4 sa e d a°
qe .
Aa a `4 a 4 d ° dd q
A
a
dl c d ♦, ° 4 '
d
/ d ° d a °d a d a ♦.
A° d ° a a d' a � b
/I I
/ ♦ d e 8 \d d d a ° q d a dd
d a d S dd ° ep a
/ d q e. ° d °
/ ee °�° °4 a d— �' ad d n
°
d d ° d 4 ° d4
a ° d' a e. d d
/ a° d v ° A ° ° ° ° ' ° ° a - d a d
dd ° ° d d 4
e 6 °a dA d° �. ° e d
° °d d ° a d f�\° as d. 4 d°
d e n d 4
e
d4 d d a. d
4
aA
°6�, d d ° d ° d d a
l a ° ♦ a° a d
/. da e a d a n
ad a A° a'
q d° c d a n ° ° da d
FF=254.00 4 d 4♦ d° d d 14
a
44
° d °° d �. ad a s a
d a ° U) e d
PROPOSED BUILDING d 4 U)
e a a ° I CONNECT EXISTNG Nd
4 ° 4 a q 9° NEG 0 ��I •
a ° d ♦ , STA. 1 + 84:63' Ld a
d d APPROXh E, = 237.17
d d CONT17AC OR TO VERIFY) ° 4 ° e ♦ d a 'a/1
d a d1 i LF 6" VC aSDR—° ®J.76� j LOCATION, PIPE TYPE, AND
d d d 4 C Ss, S —T $ ECEVATIO PRIOR °—.�
e
dd ♦ ; a 4° 0 N d
° a d 'a
ed, ° 4. 4 4 ° °. -
a � __° a 4a
d a° 4 ,4 A° cn TO u
q°
d♦
d ° °da °CLEANUT° aa
ad bp, �-- 7 _
d ds 1. L ° A. " d
SIA: 14+24, 13St SO so a
e 4 d R
"i=48..T0 44 E6°
a a
4 a 4 - a
d
4 ° d d.
d
a..a
° a d d d U)
° a
4a
a E qA 4.
F 4 q,
4
ad
a dd °
e a a ° a s d
aa4
4 d $n
—��4
1
4 4.
4 d
/ a
14
/ q 4 Z 4
4
10410011+00
0-42+00
.—. SD — SO'— SD:— SD —�D --/SD — SD.— 3D
SD — SD — SD -- SD __
i 5D .._ SD — `
—r � sr —SD —So— st -
Sri
Aso—SD—so—sD—sD—
so
s
b
13+00
SD—Sp--SD—SD
a d
4d da
y[{ i
e a 1. a ° ° '. ✓ `��.
v, y
ti
4
5)/
0
TPN
SO —so
TPN 2021049116
Know what's below.
Call before you dig.
NOTE:
THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER
APPROVAL DATE. THE CITY WILL NOT BE
RESPONSIBLE FOR ERRORS AND/OR OMISSIONS
ON THESE PLANS.
FIELD CONDITIONS MAY DICTATE CHANGES TO
THESE PLANS AS DETERMINED BY THE CITY
ENGINEER.
PERMIT NO. XX—XXXXXX—XX
APPROVED
DATE
EGEND
LEGAL DESCRIPTION
(PER DEED UNDER INSTRUMENT NO. 20201230000748)
LOTS 1, 2, 3, AND 4, KING COUNTY SHORT PLAT NUMBER 274023, RECORDED
H-0
FOUND MONUMENT AS NOTED
UNDER RECORDING NUMBER 8011050835, IN KING COUNTY, WASHINGTON;
CALCULATED MONUMENT AS NOTED
TOGETHER OATH THAT PORTION OF VACATED STATE HIGHWAY AND ADJOINING SAID
LOTS 3 AND 4, AS RECORDED UNDER RECORDING NUMBERS 8212060518 AND
(C)
CALCULATED DIMENSION
8212060520, AND CORRECTED UNDER RECORDING NUMBERS 8307070635 AND
(M)
MEASURED DIMENSION
8307070636.
(Rx)
RECORD DOCUMENT (PER REFERENCE)
EXCEPT THOSE PORTIONS CONVEYED TO THE CITY OF FEDERAL WAY BY
INSTRUMENTS RECORDED UNDER RECORDING NUMBERS 20160108000112,
TPN
TAX PARCEL NUMBER
20160108000113 AND 20160108000115.
BOUNDARY LINE
ADJOINER PROPERTY BOUNDARY
RIGHT OF WAY LINE
ROAD CENTERLINE
EASEMENT LINE
-- ---- -- - SHORT PLAT LINE
SECTION LINE
AREA COVERED BY CONTAINERS
O GATE POST
0 0 0 6' CHAIN LINK FENCE
a- WROUGHT IRON FENCE
MINOR CONTOUR
- -- - -- - MAJOR CONTOUR
x 0.0' SPOT ELEVATION
0 SANITARY SEWER MANHOLE
0 SANITARY SEWER CLEANOUT
SANITARY SEWER STUB
0 STORM MANHOLE
❑ STORM CATCH BASIN
< STORM CULVERT
- SD- SD- SD- BURIED STORM DRAIN LINE
- - - - - - - STORM DITCH LINE
- sS - Ss - Ss - BURIED SANITARY SEWER LINE
IE INVERT ELEVATION
PVC PLASTIC PIPE
DI DUCTILE IRON PIPE
RCP REINFORCED CONCRETE PIPE
-0- UTILITY POLE
© POWER VAULT
0 POWER METER
m JUNCTION BOX
Q TRANSFORMER
x( LIGHT POLE
PLANT 2 RELOCATION
BOUNDARY AND TOPOGRAPHIC SURVEY
SOUTH 1' OF THE S"E" 114 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M.,
ryOF FEDERAL WAY, KING COUNTY, WASHINGTON
Zy4 TPN 1852950050
6' CHAIN LINK FENCE CORNER
1.5' NORTH OF LINE
BUILDING
I ' ' 235.62' / '
- -
POWER EASEMENT / 1 10'.00
REC NO 20160425000549 65' \ 7 3 5 BUILDING CORNER ON
yH PROPERTY LINE 1 / BUILDING
252.-- ' LOT 1
TPN 2 21049163
LOT 2
TPN I
\ 20210491621
i M
8
.hH
a S88'kO5`E \
I ^
�62
N88'35'45'W 283.95' 4
a
ROW DEDICATION UNDER / I \ BUILDING
REC. NO. 20160108000112
,2Ao a // - LOT -1
/ TPN 2021049155 A\ I I
20' POWER EASEMENT \
yN / / i UNDER REC. NO. 8108200646 I SH
/ V6 Jl•
ROW VACATION UNDER N 6
REC. NOS. 11307070635
& 8307070636
-��20
1 A STORM CATCH BASIN a n 4
241 , / \ RIM=253.63' ^
\ p� E=251.53' (4" PVC-N)1 I '
��• ��° / �oM IE=251.43' (4" DI-S) 1 15�8 ^ z'
Q , O IE=251.38 (4` DI-E) X
Q N88'3545`W 230.14' gyp° IE=251.78' (4" PVC-W) 1 ^ a
6'x4.5' UTILITY EASEMENT UNDER �� OO ° h STORM CATCH BASIN
(� 246- ` A I REC. NO.20160108000113 � � RIMDI-W )
I � STORM CATCH BASIN ^� IE=250.32 (8" DI-W/N) ^ a
A RIM=253.08' IE=250.5T (10" DI -SW) r i
IE=251.23' (8` DI-E) ?S< _ h
% \ 4 _
1 / \ I I / I r u/^ Iti56y
QP / 0 5 POWER EASEMENT UNDER
STORM CATCH BASIN l � 4 5000549
)*4
LIGHT POLE WITH ARM
RIM=245.46'
IE=242.16' (8" DI -NW)
ID
GAS VALVE
©
CABLE VAULT
62'`
SEWER MANHOLE
❑
TELEPHONE RISER
RIM=242.12'
\y/
CTR CHANNEL=227.22
244-'
pQ
WATER VALVE
(10' PVC-NE/SW)
ROW DEDICATION UNDER
LADDER (N)
REC. NO. 20160108D00115�
® WATER METER /
0 IRRIGATION CONTROL VALVE STORM CATCH BASIN
TYPE 2
0 UNKNOWN UTILITY MANHOLE RIM=24214'
❑v UNKNOWN UTILITY VAULT IE=231.44' (36` RCP-E)
IE=231.29' (36" RCP-W)
OHE OHE- OVERHEAD POWER LINE IE=232.99' (8" RCP-N)
NO ACCESS TO 12" ALUM-S
-oHT-OHT- OVERHEAD TELEPHONE LINE LADDER (N)
-G-G-G-G- BURIED GAS LINE
STORM MANHOLE
ASPHALT SURFACE OIL SEPARATION STRUCTURE,
RIM =242,20'- SD
CONCRETE SURFACE IE=239.05' (12" RCP -SE)
TOP DOWN PIPE=237.85 (12` ALUM-N)
GRAVEL SURFACE WATER LEVEL=236.85'
LADDER (W)
/ SEWER MANHOLE
RIM=241.89'
/CTR CHANNEL=227.09'
(10" LADDER (SE) 40
i2
SEWER MANHOLE
RIM=241.30'
:TR CHANNEL=220.35' (10" PVC-NE/SW)
LADDER (NE)
20 S 1/4 CORNER SECTION 20
0 PER ROS UNDER AFN 9307149002
29
VAULT ACCESS
RIM=241.92'
SUMP=234.07'
24 REC. N0. 20160 2
LOT 4
❑� gD --�'- SE of
°"
sD - SD _
/ I
TPN 2021049043
SEWER MANHOLE
- - -
w�
RIM=249.46'
CTR CHANNEL=22&71'
Ln
u'�
(8" PVC SW/SE, 6" PVC -NE)
y i
- 1 j
LADDER (S)
SEWER MANHOLE S
/ I I RIM=251.71' z 15' WATER EASEMENT- 25
CTR CHANNEL=228.36' (8" PVC-SW/NE)
/ 40' INGRESS, EGRESS & UTILITIES UNDER REC. NO. 6104747
EASEMENT PER SHORT PLAT'-
/l B
\ 10' SANITARY SEWER // 4V ROADWAYEASEMENT25 Xtih69
2yy \ EASEMENT UNDER UNDER REC. NO. 4447709 3 5E
\ \ \ REC. NO. 8802100900�1 40' GAS EASEMENT
\ UNDER REC. NO. 7112140378
\A iy /
-�Ss-ss�- -ss S _'-----C--- ----- G \ G-G� c c-
Sly SD s�-ss-\ss - 50(
Str�S SS �-? SS �-o- SS �OSS SS - sS
-S D
40'
T� ( " _SB8'32'22"E 304.87' - _ - EA SD SD �'
s� I No REC.
asp 5' POWER EASEMENT I I STORM CU
sp UNDER REC. NO. 7403120485 6, TALLso 8.67' IE=247.63'
STORM CULVERT CHAIN LINK FENCE
STORM CULVERT IE=242.34' (12" RCP)
IE=241.09' (8' DI) Na STORM
2CATCH
40' SANITARY SEWER
STORM CULVERT EASEMENT UNDER RIM=250.37'
IE=241.48' (W RCP) REC. NO. 850 IA"Al SEWER MANHOLE Na IE=244.87' (12
STORM CATCH BASIN RIM=251.53' STORM CATCH BASIN IE=244.82' (12
TYPE 2-OVERFLOW CONTROL STRUCTURE CTR CHANNEL=228.13 (8` PVC-W/NE) TYPE 2 LADDER (S)
RIM= 7.62' ' TPN 2021049148 LADDER (NE) RIM=251.48'
IE=237.62' (36" CMP-E) I IE=233.18' (36" RCP -NE)
IE=239.97' (4` PVC -SE) IE=233.13 (36` RCP-W)
STANDPIPE IE (GATE)=237.84' (8` DI -SW) I IE=233.58' (24" PVC -SE)
TOP=241.22' LADDER (N)
BTM=235.62'
WATER LEVEL=237.67'
LADDER (N)
EASE
REC.
N8812'22"W 2613.72'(C) - -
BUILDING CORNER ON
PROPERTY LINE
6 CHAIN LINK FENCE CORNER
-1.1' EAST & 1.0' SOUTH OF LINE
TPN 1852950010
w
Z
WALLED SHED
6FT CHAIN LINK FENCE
1.5' EAST OF LINE
L
MANHOLE
.50'
0' (36" RCP -NE)
5'(36" RCP -SW)
0 0 (24` PVC -SE)
--------
so_'`'D- --------
SD� SD N
/ so 5/ 5 I 1 SEWER MANHOLE - - - -
/ / 5
RIM=249.49'
� �7 q$ I CTR CHANNEL=229.29'
/ i �,,, 13V6c�9E 40' SA NTAUNDER SEWERRY (8" PVC-SW/NE, 6" PVC -SE)
i / N65 REC. NO. 8601130472 DER (N)
SEWER MANHOLE
STORM CULVERT
IE=247.32' (8` DI) RIM=249.13'
CTR CHANNEL=226.78'(8" PVC-NE/NW)
LADDER (SE)
STORM CATCH BASIN I
TYPE 2 I TPN 2021049116
RIM=249.50' I
IE=246.25' (12' DI=SW)
ER SEWER LADDER
(N (12` DI-S)
LADDER (N)
NO. 8601130471 STORM MANHOLE
LVERT RIM=249.25' I
(8" DI) NO ACCESS, BOLT DAMAGED v
BASIN �
TPN 2021049059
" DI -NE)
` DI-W)
to
Iz
I
I
I
I
I
I
I
I
I
I
1, 921.92'(R1)
21
20,
FOUND 1.5" BRASS DISC
IN MONUMENT CASE
0.8' BELOW SURFACE
VISITED 3-25-13
I
W
4
GRAPHIC SCALE
40 0 20 40
( IN FEET )
1 inch = 40ft.
BASIS OF BEARINGS
HELD NORTH 01'34'24" ALONG THE EAST LINE OF SECTION 20 BETWEEN FOUND MONUMENTS, AS SHOWN
HEREON.
HORIZONTAL DATUM
WASHINGTON STATE PLANE COORDINATE SYSTEM, NORTH ZONE (NAD 8312011) BASED ON RIK GPS
iv MEASUREMENTS CONSTRAINED TO THE WASHINGTON STATE REFERENCE NETWORK.
VERTICAL DATUM
Z I BASSEEDO N RTK GPS MEASUREMENTS CONSTRAINED TO THE WASHINGTON STATE REFERENCE NETWORK AND TIED
TO WSOOT BENCHMARK GP27099-140.
BM GP27099-140 ELEV=81.46 (NAVD88)
ELEVATIONS CONVERTED TO CITY OF FEDERAL WAY DATUM USING USACE CORPSCON SOFTWARE VERSION 6.0.1.
a BM GP27099-140 ELEV=77.96 (NGVD29)
N SURVEY NOTES
I
c i. DATA FOR THIS SURVEY WAS GATHERED BY FIELD TRAVERSE UTILIZING ELECTRONIC DATA COLLECTION, AND
z I MEETS OR EXCEEDS ACCURACY REQUIREMENTS CONTAINED IN W.A.C. 332.130.090. ALL MEASURING
INSTRUMENTS EMPLOYED IN THIS SURVEY HAVE BEEN MAINTAINED IN ACCORDANCE WITH MANUFACTURERS
SPECIFICATIONS.
2. THIS MAP GRAPHICALLY REPRESENTS CONDITIONS AND FEATURES EXISTING AT THE TIME OF THIS SURVEY
ONLY, WHICH WAS PERFORMED DURING SEPTEMBER OF 2021.
3. THE CERTIFICATION OF THIS SURVEY AND MAP IS EXCLUSIVE TO THE NAMED CLIENT WHO REQUESTED THIS
SURVEY. IT WAS SPECIFICALLY DESIGNED TO MEET THEIR STATED NEED(S). THAT CERTIFICATION DOES NOT
EXTEND TO ANY OTHER PARTIES OR FOR ANY ALTERNATIVE USE OF THIS MAP WITHOUT THE EXPRESS
RECERTIFICATION BY THE SURVEYOR NAMING THOSE PARTIES.
4. THE PURPOSE OF THIS SURVEY IS TO PROVIDE A TOPOGRAPHIC MAP OF THE EXISTING CONDITIONS WITHIN
PARCEL NUMBERS 2021049163, 2021049162. 2021049155, & 2021049043 FOR PLANNING, DESIGN AND
CONSTRUCTION.
5. UTILITIES OTHER THAN SHOWN MAY EXIST ON THE SITE. THE SURVEYOR DOES NOT WARRANT THAT THE
UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. LACKING EXCAVATION, THE EXACT
LOCATION OF UNDERGROUND FEATURES CANNOT BE ACCURATELY, COMPLETELY, AND RELIABLY DEPICTED.
WHERE ADDITIONAL OR MORE DETAILED INFORMATION IS REQUIRED, THE CLIENT IS ADVISED THAT
EXCAVATION MAY BE NECESSARY. THE SURVEYOR DOES CERTIFY THAT THEY ARE SHOWN AS ACCURATELY
AS POSSIBLE FROM FIELD SURVEY INFORMATION.
6. KING COUNTY PARCEL NUMBERS 2021049163, 2021049162, 2021049155, & 2021049W
7. PARCEL AREA (TPN 2021049163): 32,979 t SQ.FT. (0.76 ACRES)
PARCEL AREA (TPN 2021049162): 307,804 f SQ.FT. (0.87 ACRES)
PARCEL AREA (TPN 2021049155): 55,508 t SQ.FT. (1.27 ACRES)
PARCEL AREA (TPN 2021049043): 58,221 f SQ.FT. (1.34 ACRES)
8. ALL DISTANCES AND DIMENSIONS SHOWN ARE U.S. SURVEY FEET GROUND MEASUREMENTS.
9. CONTOUR INTERVALS ARE 1-FOOT AND ARE COMPUTER GENERATED FROM GROUND FIELD TOPOGRAPHY
GATHERED FOR THIS SURVEY UTILIZING ELECTRONIC DATA COLLECTION.
10. THE PROPERTY AND PUBLIC RIGHT-OF-WAY LINES SHOWN HEREON ARE BASED ON RECORD DOCUMENTS
11, WE HAVE USED GRAPHIC SYMBOLS TO REPRESENT SOME FEATURES ON THIS MAP, SUCH AS UTILITIES, TREES
AND FENCES. THE DEFAULT SIZE OF THOSE SYMBOLS MAY NOT REFLECT THE TRUE SIZE OF THE FEATURE
THAT WAS MAPPED.
20 21
29128
1. KING COUNTY SHORT PLAT NO. 274023 UNDER RECORDING NO. 8011050835.
SURVEYOR'S CERTIFICATE
I HEREBY CERTIFY THAT THIS MAP CORRECTLY REPRESENTS A TOPOGRAPHIC SURVEY MADE BY ME
OR UNDER MY DIRECTION AND TO THE BEST OF MY KNOWLEDGE REPRESENTS THE SURFACE
FEATURES AS THEY EXIST ON THE GROUND AS OF 0913012021.
J.
FOUND 3" BRASS DISC
W/"X"IN MONUMENT CASE
VISITED 9-27-21
P.L.S. NO. 45792 DATE
NOTE:
THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER
APPROVAL DATE. THE CITY WILL NOT BE
RESPONSIBLE FOR ERRORS AND/OR OMISSIONS
ON THESE PLANS.
FIELD CONDITIONS MAY DICTATE CHANGES TO
THESE PLANS AS DETERMINED BY THE CITY
ENGINEER.
PERMIT NO. XX-XXXXXX-XX
APPROVED
DATE