HomeMy WebLinkAbout15-101339 1
i _ Electrical
• City of Federal Way
Community&Econ.Dev.ServicesIL
F E
Permit #: 15-101339-00-EL
33325 8th Ave S
Federal Way,WA 3 Inspection Request Line: 25
Ph:(253)835-2607 Fax:(253)835-2609 P q ( 3)835-3050
Project Name: FREEMAN
Project Address: 29020 7TH PL S Parcel Number: 515290 0030
Project Description: Replaced existing Zinsco Panel with new 200A Panel.Installing 100A sub Panel for
Swimming Pool.Install all pool equipment and bonding.
Owner Applicant Contractor
LYNN FREEMAN TRIGVE FELTUS DESTINY CITY ELECTRIC LLC
29020 7TH PL S DESTINY CITY ELECTRIC LLC DESTICE886N2(8/22/16)
FEDERAL WAY WA 98003-3607 11012 CANYON RD E SUITE 8-164 11012 CANYON RD E SUITE 8-164
PUYALLUP WA 98373 PUYALLUP WA 98373
Additional Permit Information '.
Is this an Online or O.T.C.application? Yes Is Use Educational or Institutional? No
Electrical Fixtures:
Alt.Serv./Feeder:0 to 200 amps(F 1 Circuits-Residential 4 Swimming PooL
PERMIT EXPIRES Monday, September 14, 2015
Permit Issued on.Wednesday, March 18, 2015
I hereby certify that the above information is correct and that the construction on the above described property and
the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington
and the City of Federal Way.
Owner or agent: 0111._I N E Date:
A-s
- ,4 -.
Ct4K z-
DATE INSPECTOR • AREA AND TYPE OF 'NSPECTIQN
51 It ( cam IMA PA44f4I Nol &4111 - 0 To COM/ poo( 51Aat RMAA 0`^41
THIS CARD IS T MAIN ON-SITE'
"Ta 414'
• Construction I ection Record ..
Federal Way INSPECTION REQU TS: (253)835-3050
PERMIT#: 15-101339-00-EL Address: 29020 7TH PL S
Project: LYNN FREEMAN FEDERAL WAY, WA 98003-3607
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as
possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your
inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
CI LIFER Ground(4295) 0 Ditch cover(4030) 0 Slab/Concrete Floor(4255)
Approved Approved Approved to place concrete
By Date By 14,6 Date S l cc IS— By Date
❑ Pool Bonding(4195) 0 Temporary Power(4275) Service(4235)
Approved Approved Approved
By Date By Date By QAmi, Date
0 Feeders/Sub-panels(4045) 0 Rough Electrical(4225) El Ceiling Cover(4020)
Approved Approved
Approved
By Date By Date By Date
'
ID Final-Electrical(4055)
Approved
By a- 4
1f Date 9,_i 4 `"� -
El Rough Electrical El Final Electrical Right of Way
Approved Approved Approved
By Date By Date • By Date