HomeMy WebLinkAbout15-100518 Demolition
City of Federal Way Permit #: 15-100518-00-DE
Community Econ.& Dev.Services
33325 8th Ave S
Federal Way,WA 98003
Ph:(253)835-2607 Fax (253)835-2609 Inspection Request Line: (253) 835-3050
Project Name: FEDERAL WAY HIG SC - SE I DEMOLITION
Project Address: 30611 16TH AVE S Parcel Number: 082104 9001
Project Description: Demolition of southernmost portion of existing school building.separate fire alarm permit
required
Owner Applicant Contractor
FEDERAL WAY PUBLIC SCHOOLS W M DICKSON CO W M DICKSON CO
33330 8TH AVE S 3315 S PINE ST WMDICC*108J7(4/1/15)
FEDERAL WAY WA 98003 TACOMA WA 98409-5718 3315 S PINE ST
TACOMA WA 98409-5718
Additional Permit Information
Demolition Valuation 65000
PERMIT EXPIRES Thursday, February 16, 2017
Permit Issued on Tuesday, February 17, 2015
I hereby certify that the above information is correct and that the construction on the above described property and
the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington
and the City of Federal Way.
Owner or agent: :1_,:)..e____ :41..,.
a Date: %AV).L'-) I;
THIS CARD IS TO REMAIN ON-SITE
Fed �`� Construction Inspection Record
eral Way INSPECTION REQUESTS: O 253 835-3050
PERMIT#: 15-100518-00-DE Address: 30611 16TH AVE S
Project: FEDERAL WAY PUBLIC SCHOOLS FEDERAL WAY, WA 98003-4903
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as
possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your
inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
0 Final-Building(4050)
Approved jB /� Date _ / (
/ __ t
.El Rough ElectricalCI Final Electrical CI Right of Way
Approved Approved Approved
By Date By Date By Date
t ,
• ID' ary or RECEIVED PERMIT APPLICATION
Federal Way
FEB 0 3 2015
OF FE W
PERMIT NUMBER / — bC� - +.A / 1 r"'/ ('� / 5
1TARGET DATE / !!(
SITE ADDRESS SUITE/UNIT#
30611 IP " 1 51 redeni �Av qt 3005
PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL#
$ ( ; O!O0ac2 0 R c / 0 V - 9 D 0 /
TYPE OF PERMIT ❑ BUILDING ❑ PLUMBING ❑ MECHANICAL XI DEMOLITION�J❑ ENGINEER1NNG ❑ FIRE PREVENTION
NAME OF PROJECT Fei�trec�l Way Cf 4. ',t o' l Si 1 t e&&o 1,4t'ON
ne- i- '.- �e t)III!t'c9A e -I"f. SdLtf1 SO o-! Fh'I
PROJECT DESCRIPTION
Detailed description of work to
be included on this permit only
NAME i- PRIMARY PHONE
PROPERTY OWNER I ett?i 'c.1 Way e' /1 C $'G LiS `:)t-;s--4(411 -4 a'5 7
MAILING ADDRESS E-MAIL
33 36 'f`' stat S y yS
CITY r cY e rok UO`( STATE
ZIP
. 4- ' g 6(9
)/' PHONE/� !;3-4?)
'J ^ �,/// cy��
NAME yV livl V b t',k`O f. Cd N� eti _{ ;73- ?J-"l-1 0
MAILING ING ADDRESS 1 EMAIL
CONTRACTOR J •S 1 S. �ru-e 5` t ('tr"L`,a.e W'v"L�l'Ch7/
0✓t,ytci
CITY STATE ZIP r
• r c� FAX
t0- CoN^A W14 QO 9SS`t? ' 1.16 1
WA STATE CONTRACTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE#
11,,f3( b'J- e C .x « ' J Li /.
NAMEPRIMARY PHONE
e a- ela ,t,„,,4-o
MAILING ADDRESS E-MAIL
APPLICANT
CITY STATE ZIP FAX
PRIMARY PHONE i f / c�
PROJECT CONTACT NAME iA `• ie ')C j'-9 77 )` '7 tl Q 1
MAILING ADDRESS MAIL
respondThe individual to es pone and i
5 sP`�C 54 e� (6)��dIre °,l vt r
to all correspondence T
concerning this application) CITY„...-- STATE CO ST1 FAX
E ZIP 8� q
NAME
PROJECT FINANCING °''l 6ZI OWNER-FINANCED
Required value of$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE
(RCW 19.27.095)
I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best
of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses, and attorneys'fees incurred in
the investigation and defense of such claim), which may be made by any person,including the undersigned, and filed against the city,
but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the
information su lied to the cit as a part of this application.
SIGNATURE:
DATE g/3/P-d (s
PRINT NAME: e VA- a
- te ti
///(((
ITC w k k
Bulletin#100—January 1,2013 Page 1 of 3 k:AI-Iandouts\Permit Application
• •
SEATTLE ASBESTOS TEST NVLAP Accreddation Lab Codes:200768 and 200876
• 19711 Scriber Lake Road,Suite D,Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810
12727 Northup Way,Suite 1,Bellevue,WA 98005,Tel:425.861.1111,Fax:425.861.1118
Website:www.seattieasbestostest.com,Ernatadmin@seattleasbestostest.com
PLM by Point Count(400 Points)
Client Job#: 10527-01 r
Attention: Mr.Herb Brod Laboratory Batch#: 201310869
Client: ENS International,Inc. Date Received: 4/22/2013
Address: 13228 NE 20th St#100,Bellevue,WA 98005 Samples Received: 7
Date Analyzed: 4/25/2013
Project: Federal Way High School, Block D
Sample Requested for Point Count 10527-D-22
Previous Analytical Information
Previously Analyzed by: Liz Dutton
Previous Batch#: 201310552
Previous Lab ID: 22
Previous Description: White powdery material with paint
Layer to be Point Counted: 1
Asbestos Type Found: Chrysotile
Asbestos Percentage Found: 2
Point Count Analytical Procedures New Lab ID: 1
Asbestos Points Non-Asbestos Points Total Points Counted
Slide 1 0 50 50
Slide 2 0 50 50
Slide 3 1 49 50
Slide 4 0 50 50
Slide 5 0 50 50
Slide 6 0 50 50
Slide 7 0 50 50
Slide 8 0 _ 50 50
Total 1 399 400
Point Count Summary Results
Type of Asbestos: Chrysotile
Percentage of Asbestos: 0.25%
Analyzed By: Liz Dutton Reviewed by: Steve(Fanyao)Zhang, President
1
• •
SEATTLE ASBESTOS TEST rtvLAp Rased5On Lab Codes:200768 and 200876
19711 Scriber Lake Road,Suite D,Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 •
12727 Northup Way,Suite 1,Bellevue,WA 98005,Tel:425.861.1111,Fax:425.861.1118
Website:www.seattleasbestostestcom,Email:admin@seattleasbestostesLcom
PLM by Point Count(400 Points)
Client Job#: 10527-01r
Attention: Mr.Herb Brod Laboratory Batch#: 201310869
Client: EHS International,Inc. Date Received: 4/22/2013
Address: 13228 NE 20th St#100,Bellevue,WA 98005 Samples Received: 7
Date Analyzed: 4/25/2013
Project: Federal Way High School,Block D
Sample Requested for Point Count 10527-D-24
Previous Analytical Information
Previously Analyzed by: Liz Dutton
Previous Batch#: 201310552
Previous Lab ID: 24
Previous Description: White powdery material with paint
Layer to be Point Counted: 2
Asbestos Type Found: Chrysotile
Asbestos Percentage Found: 2
Point Count Analytical Procedures New Lab ID: 2
Asbestos Points Non-Asbestos Points Total Points Counted
Slide 1 0 50 50
Slide 2 0 50 50
Slide 3 1 49 50
Slide 4 1 49 50
Slide 5 0 50 50
Slide 6 0 50 50
Slide 7 0 50 50
Slide 8 0 50 50
Total 2 398 400
Point Count Summary Results
Type of Asbestos: Chrysotile
Percentage of Asbestos: 0.5%
Analyzed By: Liz Dutton Reviewed by: Steve(Fanyao)Zhang,President
2
, , • .
ëhsi 4
FHS-International, Inc.
13228 NE 20th Street, Suite 100
Bellevue, Washington 98005-2049
Phone 425-455-2959
Toll Free 800-666-2959
Fax 425-646 7247 LIMITED HAZARDOUS MATERIALS
SURVEY REPORT
FEDERAL WAY SCHOOL DISTRICT
FEDERAL WAY HIGH SCHOOL
30611 - 16th Avenue South
Federal Way, Washington
i
�_
• July 10, 2013
Prepared For:
Federal Way School District
c/o Jesse Ahlberg
Greene Gasaway Architects
31620-23rd Ave. S. #207
Federal Way, WA 98003
• Environmental Engineering
• Earth Sciences and Mapping
• Industrial Hygiene Services
• Construction Management
0 •
ehs NI 4 .
EHS-International, Inc.
Limited Hazardous Materials
Survey Report
Federal Way High School
30611 - 16th Avenue South,
Federal Way, Washington
EHSI Project No. : # 10527
The material and data in this report were prepared under the supervision and
direction of the undersigned.
Report Approved By:
//
Herb Brod
EHSI Hazardous Materials Services Manager
ehsi4.0 ii
EHS-International,Inc.
® •
TABLE OF CONTENTS
Acronym List iv
1.0 EXECUTIVE SUMMARY 1
1.1 BACKGROUND 1
1.2 EXTENT OF CURRENT SURVEY 1
1.3 MATERIALS FOUND 1
1.4 OPINIONS AND RECOMMENDATIONS 12
1.5 LIMITATIONS/DISCLAIMER 13
2.0 LIMITED HAZARDOUS MATERIALS SURVEY REPORT14
2.1 BACKGROUND 14
2.2 BUILDING DESCRIPTION 14
2.3 SAMPLING METHODOLOGY 16
2.3.1 Asbestos-Containing Materials 16
2.3.2 Lead-Containing Paint/Lead-Containing Materials 17
2.3.3 Arsenic-Containing Materials 17
2.4 SAMPLING RESULTS 17
2.4.1 Asbestos-Containing Materials 17
2.4.2 Lead-Containing Paint and Building Materials 118
2.4.3 Arsenic-Containing Building Materials 151
2.4.4 Toxic Characteristic Leaching Procedure Sampling 151
2.4.5 Polychlorinated Biphenyls 152
2.4.6 Mercury-Containing Fluorescent Light Tubes 152
3.0 LIMITATIONS 156
4.0 STANDARD OF CARE 157
5.0 CERTIFIED AHERA BUILDING INSPECTORS 157
APPENDICES
A Asbestos Analytical Laboratory Report and Field Data Forms
B Lead and Arsenic Laboratory Reports and Field Data Forms
C Certified AHERA Building Inspector Certificates
D Laboratory Certifications for Asbestos, Lead, and Arsenic
Analysis
E Sample Location Drawings for Asbestos, Lead, and Arsenic
ehsi alb
EHS-International,Inc.
•
ACRONYM LIST
ACM Asbestos-Containing Material
ACT Acoustic Ceiling Tiles
AHERA Asbestos Hazard Emergency Response Act
AHU Air Handling Unit
AIHA American Industrial Hygiene Association
As Arsenic
BMU Brick Masonry Unit
CAB Cement Asbestos Board
CB Cove Base
CFR Code of Federal Regulations
DOSH Washington State Department of Labor and Industries, Division of
Occupational Safety and Health
EA Each
Ecology Washington State Department of Ecology
EFIS Exterior Finishing Insulation System
EHSI EHS-International, Inc.
ELLAP Environmental Lead Laboratory Accreditation Program
GWB Gypsum Wall Board
Hg Mercury
JC Joint Compound
LCM Lead-Containing Material
LCP Lead-Containing Paint
L&I Washington State Department of Labor and Industries
mg/L Milligrams Per Liter
mg/m3 Milligrams Per Cubic Meter
N/A Not Applicable
ND None Detected
NVL NVL Laboratories, Inc.
NVLAP National Voluntary Laboratory Accreditation Program
OSHA US Occupational Safety and Health Administration
Pb Lead
PCBs Polychlorinated Biphenyls
PLM Polarized Light Microscopy
ppm Parts per Million
PSCAA Puget Sound Clean Air Agency
QA Quality Assurance
RCW Revised Code of Washington
SACT Suspended Acoustical Ceiling Tiles
SAT Seattle Asbestos Test, LLC
SF Square Feet
SVF Sheet Vinyl Flooring
TCLP Toxic Characteristic Leachate Procedure
TSI Thermal System Insulation
VAT Vinyl Asbestos Tile
VCT Vinyl Composite Tile
WAC Washington Administrative Code
WT Weight
w/ With
XRF x-ray fluorescence
ehsi4 iv
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
1.0 EXECUTIVE SUMMARY
1.1 BACKGROUND
Federal Way School District (FWSD) has contracted Greene Gasaway Architects (GGA) to
lead the design team for the Federal Way High School demolition project, located at 30611-
16th Avenue South, Federal Way, Washington. In conjunction with that project FWSD
contracted EHS-International, Inc. (EHSI), a hazardous materials and industrial hygiene
consulting firm, to conduct a Limited Hazardous Materials Survey of the Federal Way High
School. The intent of the survey is to specifically identify and quantify asbestos-containing
building materials (ACM), lead-containing paint (LCP), other lead-containing building
materials (LCM), arsenic-containing brick masonry unit (BMU) mortar, polychlorinated
biphenyl (PCB)-containing light ballasts, and mercury (Hg)-containing light tubes and lamps
that may be impacted by the Project.
1.2 EXTENT OF CURRENT SURVEY
EHSI inspected all accessible interior and exterior materials potentially impacted by the
proposed project. Accessible suspect materials were sampled including, but not limited to;
interior and exterior wall systems, ceiling and floor systems, mechanical systems, windows,
and roofing materials. EHSI accomplished representative destructive inspection; however, in
areas inaccessible for inspection (e.g., fire door cores, casework mastics, chalk/cork/dry
erase board, mirror and student locker mastics, enclosed plaster wall chases, electrical
panel components, boiler internals and materials above hard lid ceilings) suspect materials
were assumed to be ACM.
1.3 MATERIALS FOUND
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL DESCRIPTION LOCATION
Block A
Multiple layers of ACM black asphaltic built up
roofing with ACM tar on non ACM brown fibrous Interstitial Space above Boy's Locker Room
insulation on ACM black asphaltic vapor barrier
on wood
Non-ACM 12"x12" VCT w/ non-ACM yellow
mastic on non-ACM gray leveling compound on Gym Corridor
ACM black mastic on concrete
ACM brown stair tread on non-ACM green, 2nd Floor Stairwell 1 and 2
brown, and yellow mastic on wood
ACM brown SVF stair landing on non-ACM yellow 2nd Floor Stairwell 1 and 2
mastic on wood
ACM 8" stair stringer w/ non-ACM brown mastic 2nd Floor Stairwell 1 and 2
ehsi..
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL DESCRIPTION LOCATION
Carpet w/ non-ACM yellow carpet mastic on
9"x9" burnt orange VAT w/ non-ACM black Marketing A75
mastic on concrete
Carpet w/ non-ACM yellow carpet mastic on non-
ACM gray leveling compound on 9"x9" burnt Marketing A75 Storage A76 and A77
orange VAT w/ non-ACM black mastic on
concrete
Blue carpet w/ non-ACM yellow carpet mastic on
non-ACM gray leveling compound on ACM ASB A5
residual black mastic on concrete
Hard wood floor w/ non-ACM brown paper vapor
barrier w/ non-ACM black asphaltic backing on
hardwood floor sleepers on ACM multi-layered Main Gymnasium
black asphaltic vapor barrier beneath tarred to
concrete
Lockers A10, Lockers A24, Exercise A33,
Assumed ACM white board mastic Training A38, Lockers A50/A60, and
marketing A75
Assumed ACM tack board mastic Marketing A75
Assumed ACM cabinet mastic Weights A39
Assumed ACM mirror mastic Boy's and Girl's Locker Rooms, Weight Room
A39, and Restroom
Assumed ACM electrical panel backing Mechanical Room
Assumed ACM fire doors Throughout
Assumed ACM TSI on small bore pipe runs and Throughout
fitting (concealed in plumbing walls and ceilings)
Block B
Non-ACM 12"x12" blue VCT w/ non-ACM yellow Cafeteria B1/B2
mastic on ACM residual black mastic on concrete
ACM Gray window glazing putty on 4'x5'
windows Corridor B5
Non-ACM 4"tan/gray CB w/ non-ACM crème
colored mastic on ACM residual brown mastic on Corridor B5
concrete
ACM Gray window glazing putty on 4'x3' Cafeteria B2
clearstory windows
Assumed ACM mirror mastic Kitchen Restroom, Kitchen 5-9
Assumed ACM white board mastic Throughout
Assumed ACM fire doors Throughout
Assumed ACM TSI on small bore pipe runs and Throughout
fitting (concealed in plumbing walls and ceilings)
Block C
ehs .i
EHS-International,Inc. 2
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL DESCRIPTION LOCATION
ACM black sink undercoat Faculty Lounge
Non-ACM 12"x12" blue VCT w/ non-ACM yellow Original Building
mastic on non-ACM gray leveling compound on Corridor C-116
ACM residual black mastic on concrete
Non-ACM 12"x12" light gray VCT w/ non-ACM
yellow/tan mastic on non-ACM gray leveling Original Building
compound on 9"x9" black VAT w/ ACM black Corridor C-116
mastic on concrete
Non-ACM 12"x12" off-white VCT (w/ brown,
yellow, and white streaks) w/ non-ACM yellow Original Building Passage C-115
mastic on non-ACM gray leveling compound on
ACM residual black mastic on concrete
Carpet w/ non-ACM beige and yellow carpet
mastic on 12"x12" off-white non-ACM VCT (w/ Original Building
brown, yellow, and white streaks) w/ non ACM Copy C-111, Data Processing, Conference C-
yellow mastic on non-ACM gray leveling 108
compound on ACM residual black mastic on
concrete
Non-ACM light gray SVF (w/ broken rock
pattern) w/ non-ACM brown paper backing w/
non-ACM mastic on non-ACM gray/brown Janitor C-110
leveling compound on ACM residual black mastic
on concrete
Blue carpet w/ non-ACM yellow/brown mastic on
non-ACM gray leveling compound on ACM Original Building C-107
residual black mastic on concrete
Carpet w/non-ACM yellow/tan mastic on non-
ACM gray leveling compound on 9"x9" black VAT Original Building Girls C-135
w/ ACM black mastic on concrete
Non-ACM orange SVF (with yellow and brown
streaks) with non-ACM yellow mastic w/ ACM Original Building 2nd Floor Janitor Closet C-
gray paper backing on ACM residual black mastic 217
on concrete
Non-ACM light gray SVF (w/ broken rock
pattern) with non-ACM beige paper backing and Original Building 2nd Floor Storage C-218
non-ACM beige mastic w/ 9"x9" black VAT w/
ACM black mastic on concrete
Non-ACM 12"x12" off-white VCT (w/ brown,
yellow, and white streaks) with non-ACM yellow Original Building 2nd Floor Corridor C-216
mastic on non-ACM gray leveling compound on
9"x9" black VAT w/ ACM black mastic on wood
Carpet with non-ACM yellow mastic on 9"x9" Original Building 2nd Floor E. Classroom C-
dark red VAT w/ ACM black mastic on wood 206
ehsieb.
EHS-International,Inc.
• i
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL DESCRIPTION LOCATION
Carpet with non-ACM yellow/brown mastic on
ACM residual black mastic on non-ACM Original Building 2nd Floor E. Classroom C-
fiberboard with non-ACM clear coat on hard 206
wood floor on non-ACM black vapor barrier
ACM NicoliteTM in wood fire wall Original Building Attic
ACM Black asphaltic sealant at vent penetration Original Building Attic
ACM MAG TSI pipe run (<6" OD) in wall Original Building 2nd Floor Room
Replacement of Stairs
Carpet with non-ACM yellow mastic on 9"x9"
Building Addition 2nd Floor E. Classroom C-
Carpet
VAT w/ ACM black mastic on wood 211, C 212, C 213, C 215, and Corridor C
214
Non-ACM 12"x12" off-white VCT (w/ brown,
yellow and white streaks) w/ non-ACM yellow Building Addition 1st Floor Nurse C-126 and
mastic on non-ACM gray leveling compound on Office C-128
ACM residual black mastic on concrete
Carpet w/ non-ACM yellow mastic on 9"x9" off Building Addition 1st Floor Vice Principal C-
white and gray VAT w/ ACM black mastic on 125 and Clerical C-122
concrete
Carpet w/ non-ACM yellow carpet mastic on non-
ACM gray leveling compound on ACM residual Waiting C-129
black mastic on concrete
2nd Floor Original Building E. Classroom C-
201-208, Stairwell replacement classroom,
Listening C-210 1st Floor Building Addition,
Assumed ACM white board mastic V.P. 123, 124, 125, Principal C-120,
Conference C-119, 2nd Floor Building
Addition Computers C-212, E. Classroom C-
211,213 and C-205
Assumed ACM tack board mastic 2nd floor Original Building E. Classroom C-
206
1st Floor Building Addition 1st Floor Building
Addition, V.P. 123, 124, 125, Principal C-
120, Conference C-119, Waiting C-129, ATT
Assumed ACM mastic associated with wood wall C132, BKPR C 131, Work C 130, Wait C
paneling 121, 2nd Floor Original Building E. Classroom
C-201-208, Stairwell replacement
classroom, 2nd Floor Building Addition
Computers C-212, E. Classroom C-211,213
and C-205
2nd Floor Original Building E. Classroom C-
Assumed ACM cabinet mastic 201-C-208
2nd Floor Building Addition Computers C-
212, E. Classroom C-211,213 and C-205
ehsi
EHS-International.Inc. 4
• I
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL DESCRIPTION LOCATION
Assumed ACM locker mastic 2nd Floor Original Building Corridor C-216
1st Floor Original Building Girls C-135, and
Assumed ACM mirror mastic 2nd Floor Original Building C-220
Assumed ACM electrical panels and components 1st Floor Boiler Room and 2nd Floor C-127
Assumed ACM fire doors Throughout
Assumed ACM TSI on small bore pipe runs and Throughout
fitting (concealed in plumbing walls and ceilings)
Block D
Library D-15, Conference D-16 Audio Video
Blue carpet with non ACM yellow/tan mastic on Classroom D-17, Alcove D-18, Work Room
ACM residual black mastic on concrete D-19 and Magazine D-20 1
White NicloliteTM paper in wood fire wall Library Attic
Non-ACM silver paint on ACM black asphaltic Library Attic
tar/sealant
Carpet w/ non-ACM gray foam carpet backing w/
non-ACM clear mastic on non-ACM 12"x12" off-
white VCT (w/ brown, yellow, and white streaks) Corridor D-14
w/ non-ACM yellow mastic on ACM residual black
mastic on concrete
Carpet with non-ACM brown and orange mastic
on 9"x9"tan VAT (w/ white and brown streaks) Corridor D-14
w/ ACM black mastic on concrete
Carpet w/ non-ACM gray foam carpet backing w/
non-ACM clear/yellow mastic on ACM residual Corridor D-13
black mastic on concrete
ACM black sink undercoat Office D-11
Assumed ACM white board mastic A.V. Classroom D-17, Conference D-16, S.S.
Classrooms D-1-D-8
Assumed ACM tack board mastic Library D-15,
Assumed ACM mastic associated with wood wall Library D-15, A.V. Classroom D-17, Corridor
paneling D-14 and Classrooms D-1-D-8
Assumed ACM mastic associated with wall Library D-15 and Office D-11 and
mounted book cases
Library D-15, A.V. Classroom D-17, Corridor
Assumed ACM mastic associated with casework D-14, MAG D-20,and Storage
Assumed ACM univent internals Library
Assumed ACM locker mastic Corridor D-14
Assumed ACM fire doors Throughout
Assumed ACM TSI on small bore pipe runs and Throughout
fitting (concealed in plumbing walls and ceilings)
Block E
Non-ACM 12"x12" light gray VCT with non-ACM
off-white and yellow mastic on ACM residual Corridor E-8
black mastic on concrete
ehsi. 5
EHS-International,Inc.
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL DESCRIPTION LOCATION
Non-ACM 12"x12" blue VCT with non-ACM yellow Corridor E-8
mastic on ACM residual black mastic on concrete
Carpet with non-ACM yellow mastic on ACM Vestibule E-25
residual black mastic on concrete
Carpet with non-ACM yellow mastic on 9"x9" Social Studies Classroom E-21
light blue VAT w/ ACM black mastic on concrete
9"x9" Light brown VAT with ACM black mastic on Theater E-10 and Control E-11
concrete
Carpet with non ACM yellow and orange mastic Drama Classroom E-1, Green Room E-7 and
on 9"x9"tan VAT w/ ACM black mastic on Dressing E-5
concrete
Drama Classroom E-1, Passage E-2, and
Assumed ACM white board mastic Classroom E-17 2001 Addition Classrooms
1-5
Assumed ACM mastic associated with wood wall Drama Classroom E-1, Green Room E-7,
paneling; S.S. Classroom E-21, and Classroom E-17
Assumed ACM mastic associated with wall panels Corridor E-8
Assumed ACM wiring associated with theatre Theater
stage lighting
Assumed ACM mirror mastic Women E-4
Assumed ACM fire doors Throughout
Assumed ACM TSI on small bore pipe runs and Throughout
fitting (concealed in plumbing walls and ceilings)
Block F
Non-ACM 12"x12" off-white VCT (with brown, Laundry F 2, Storage F 3, Cooking F 4,
yellow, and white streaks) w/ non-ACM yellow Office F 5, Dress F-6, Storage F 7, Sewing
mastic on ACM residual black mastic on F-8, Storage and Child Development F-11
concrete
9"x9"Tan VAT (with brown and yellow streaks) Electrical F-1
w/ ACM black mastic on concrete
9"x9" Light brown VAT (w/ rainbow streaks) w/ Electrical F-1
ACM black mastic on concrete
9"x9" Olive green VAT w/ ACM black mastic on Biology Classroom 1 and 2
concrete
9"x9" Brown/red VAT (with beige streaks) w/ Storage F-17 and F-18
ACM black mastic on concrete
Carpet w/ non-ACM clear mastic on 12"x12"
beige VAT (with brown streaks) on ACM black Electronics F-19 and Drafting F-16
mastic on concrete
Carpet with non-ACM yellow mastic on"x9" red Special Education F-13
VAT w/ ACM black mastic on concrete
ehs 4.i
EHS-International,Inc. 6
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL DESCRIPTION LOCATION
Carpet w/ non-ACM green/gray mastic w/ non-
ACM yellow mastic on 9"x9" light brown VAT (w/ Special Education F-15
rainbow streaks) w/ ACM black mastic on
concrete
ACM black sink undercoat Sewing F-8, Electronics F-19 and Drafting F-
16
Assumed ACM mastic associated with wood wall Cooking F 4, Sewing F 8, Child development
paneling F-11, Special Ed F-13,15, Drafting F-16,
Electronics F-19, and Biology Classroom's
Assumed ACM wall panel mastic Corridor F-9, 10, and 15
Cooking F-4, Sewing F-8, Child development
Assumed ACM white board mastic F-11, Special Ed F-13,15, Drafting F-16,
Electronics F-19, and Biology Classroom's
Assumed ACM tack board mastic Special Ed F-13, Corridor F-15
Assumed ACM mirror mastic Toilet F-12
Cooking F-4, Sewing F-8, Child development
Assumed ACM mastic associated with casework F-11, Special Ed F 13,15, Drafting F 16,
Electronics F-19, and Biology Classroom's,
Storage F-17 and 18, Biology Prep Rooms
Assumed ACM locker mastic Corridor F-9, 10, and 15
Assumed ACM electrical panels and components Mechanical Room and Electrical F-1
Assumed ACM fire doors Throughout
Assumed ACM TSI on small bore pipe runs and Throughout
fitting (concealed in plumbing walls and ceilings)
Block G
Non-ACM 12"x12" light gray VCT (with white and
gray streaks), blue VAT, and gray VAT (w/
maroon streaks) all w/ non-ACM tan mastic on Corridor G-13
non-ACM white leveling compound on ACM gray
VAT w/ ACM black mastic on wood
Blue/gray carpet with non-ACM tan mastic on Janitor G-9, Storage G-10A, Storage G-11,
tan VAT w/ ACM black mastic on wood and Storage G-3
Conference G-2A, Classroom G-2,
Blue/gray carpet with non-ACM tan mastic on Simulators G-1, Business Classroom G-4,
gray VAT w/ ACM black mastic on wood Computer G-5, Keyboard Classroom G-6,
and Micro Computer G-7
Corridor G-13, Conference G-2A, Classroom
Assumed ACM mastic associated with wood wall G-2, Simulators G-1, Business Classroom G-
paneling 4, Computer G-5, Keyboard Classroom G-6,
and Micro Computer G-7
Conference G-2A, Classroom G-2,
Assumed ACM mastic associated with casework Simulators G 1, Business Classroom G 4,
Computer G-5, Keyboard Classroom G-6,
and Micro Computer G-7
ehSiw
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL DESCRIPTION LOCATION
Classroom G-2, Simulators G-1, Business
Assumed ACM white board mastic Classroom G-4, Computer G-5, Keyboard
Classroom G-6, and Micro Computer G-7
Assumed ACM locker mastic Corridor G-13
Assumed ACM electrical panels and components Business Office G-10
Assumed ACM fire doors Throughout
Assumed ACM TSI on small bore pipe runs and Throughout
fitting (concealed in plumbing walls and ceilings)
Block H
Non-ACM 12"x12" beige VCT (w/ brown and Main Corridor, Room 704,705, and Office
white streaks) w/ ACM black mastic on concrete Area
Non-ACM white leveling compound on non-ACM
gray leveling compound on ACM residual black Janitor's Closet
mastic on concrete
Multi-colored carpet w/ non-ACM foam backing
w/ non-ACM clear mastic on non-ACM 12"x12"
beige VCT (w/ brown and white streaks) w/ ACM ASA Room
black mastic on concrete
Assumed ACM mastic associated with wood wall
paneling ASA Room
Assumed ACM white board mastic ASA Room, Room 704 and 705
Assumed ACM tack board mastic ASA Room, Room 704 and 705
Assumed ACM mastic associated with casework ASA Room, Room 704 and 705
Assumed ACM locker mastic Main Corridor
Assumed ACM electrical panels and components Main Corridor
Assumed ACM mirror mastic Grooming, Boy's Restroom and Girl's
Restroom
Assumed ACM fume hood baffles and internals Room 704 and 705
Assumed ACM fire doors Throughout
Assumed ACM TSI on small bore pipe runs and Throughout
fitting (concealed in plumbing walls and ceilings)
Block ]
Carpet w/ non-ACM yellow mastic on 9"x9" Math Classroom J-5 and J-8 1
brown/red VAT w/ non-ACM mastic on concrete
Non-ACM 12"x12" light gray VCT w/ non-ACM
dark gray mastic on 9"x9" light blue VAT (w/ Corridor J-2 and 3-11 2
white streaks) w/ black mastic on concrete
Carpet w/ non-ACM yellow mastic on 9"x9" tan
VAT (w/ brown and yellow streaks) w/ non-ACM Math Classroom J-7 and Health J-10 3
black mastic on concrete
9"x9" Red VAT on ACM black mastic beneath
non-ACM carpet with non-ACM carpet mastic on Math Classroom J-9 and J-6 4
concrete
Assumed ACM mastic associated with wood wall Corridor J-2, Math Classroom J-5, J-6, J-7,
paneling 3-8, J-9, Health 3-10 5
ehs .
EHS-International,Inc. 8
• •
Limited Hazardous Materials Survey Report
Federal Way High School
• EHSI Project 10527
July 12, 2013
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL DESCRIPTION LOCATION
Assumed ACM wall panel mastic Corridor J-2 and J-11 6
Assumed ACM tack board mastic Math Classroom J-9, Health J-10 7
Assumed ACM white board mastic Math Classroom J 5, J 6, J 7, J 8, J 9,
Health 3-10 8
Assumed ACM locker mastic Corridor J-11
Assumed ACM mirror mastic Girls Restroom
Assumed ACM fire doors Throughout
Assumed ACM TSI on small bore pipe runs and Throughout
fitting (concealed in plumbing walls and ceilings)
Block K
Carpet w/ non-ACM yellow/tan mastic on 9"x9" F.L. Classroom K 1, K 2, Math Office K-2
red VAT w/ non-ACM black mastic on concrete
9"x9"Tan floor tile with brown and yellow
streaks on non-ACM black mastic beneath non F.L. Classroom K-9
ACM carpet on non-ACM yellow mastic on
concrete
9"x9" Brown/red floor tile with beige streaks on F.L. Office K-6 and Conference K-7
ACM black mastic on concrete
Non-ACM 12"x12" dark gray floor tile on non-
ACM yellow mastic on 9"x9" light blue VAT on Corridor K-5
ACM black mastic on concrete
F.L. Classroom K-1, Computer K-3, Math
Assumed ACM mastic associated with wood wall Classroom K-8, F.L. Classroom K-9, F.L
paneling Office K-6, Conference K-7, F.L. Classroom
K-4, Math K-2
Assumed ACM wall panel mastic Corridor K-5
Assumed ACM tack board mastic Computer K-3
F.L. Classroom K-1, Computer K-3, Math
Assumed ACM white board mastic Classroom K-8, F.L. Classroom K-9, F.L
Office K-6, Conference K-7, F.L. Classroom
K-4, Math K-2
Assumed ACM locker mastic Corridor K-5
Assumed ACM fire doors Throughout
Assumed ACM TSI on small bore pipe runs and Throughout
fitting (concealed in plumbing walls and ceilings)
9"x9" Olive and light olive colored VAT w/ ACM Ceramics Lab L-5
black mastic on concrete
Block L
9"x9" Green VAT (w/ beige streaks) w/ ACM Art Lab L-1
black mastic on concrete
Blue/gray carpet w/ non-ACM tan mastic on non-
ACM white leveling compound on 9"x9" red VAT Office L-8
w/ ACM black mastic on concrete
110eh9
EHS-International,Inc.
i •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527 •
July 12, 2013
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL DESCRIPTION LOCATION
Non-ACM red sheet vinyl flooring with non-ACM
black asphaltic backing on ACM black mastic on Metal Shop L-13 and Office L-9
concrete
ACM gray caulking around metal seismic wall
brackets Corridor L-6
Assumed ACM mastic associated with wood wall Art Lab L-1, Ceramics Lab L-5, Storage L-3
paneling and L-4 6
Assumed ACM mastic associated with casework Art Lab L-1
Assumed ACM electrical panels and components Metal Shop L-13
Assumed ACM tack board mastic Office L-2
Assumed ACM white board mastic Art Lab L-land Shop Classroom L-7
Assumed ACM locker mastic Corridor L-6
Assumed ACM fire doors Throughout
Assumed ACM TSI on small bore pipe runs and Throughout
fitting (concealed in plumbing walls and ceilings)
Block M
9"x9" Olive colored VAT (w/ pink and beige
streaks) w/ ACM black mastic on concrete Choral M-26
Non-ACM 12"x12" blue VCT w/ non-ACM yellow Corridor M-1 and Corridor M-12
mastic on ACM residual black mastic on concrete
Non-ACM blue/gray carpet w/ non-ACM tan
mastic on 9"x9" Olive colored VAT (w/ pink and Passage M-28, Practice 3, M-29, and M-31
beige streaks) w/ ACM black mastic on concrete
Non-ACM blue/gray carpet w/ non-ACM tan Ensemble M 13, Practice M 14, Practice M
mastic on 9"x9" red VAT w/ non-ACM black 15, Instrument M 19, Office M 20, Storage
mastic on concrete M-22, Library M-23, Storage M-24, Office M-
25
Non-ACM 12"x12" light gray VCT (w/ maroon Storage M-2, Mechanical M-5, Office/Lab M-
and white streaks) w/ ACM black mastic on 9, Storage M-34, Film M-35, Print M-36,
concrete Print M-37, Photo Lab M-38
9"x9"Yellow floor tile (w/ brown and black Science Classroom M-11
streaks) w/ ACM black mastic on concrete
Assumed ACM mastic associated with wood wall Physics Lab M 7, Chemistry Lab M-6 Band
paneling M-17, Office M-20, Storage M-22, Photo Lab
M-38
Physics Lab M-7 and associated Offices,
Chemistry Lab M-6, Office Lab M-9, Science
Classroom M-11, Ensemble M-13,
Assumed ACM mastic associated with casework Instrument Storage M-19, Office M-20,
Storage M-22, Library M-23,Office M-25,
Storage M-34, Film M-35, Print M-36, and
Photo Lab M-38
Assumed ACM locker mastic Corridor M-12
Physics Lab M-7, Chemistry Lab M-6,
Assumed ACM white board mastic Science Classroom M-11, Band M-17,Entry
M-18 Choral M-26, Photo Lab M-38
ehs .
10
EHS-International,Inc.
• 1
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL DESCRIPTION LOCATION
Assumed ACM fume hood baffles and internals Physics Lab M 7, Chemistry Office/Lab M 9,
Science Classroom M-11,
Assumed ACM fire doors Throughout
Assumed ACM TSI on small bore pipe runs and Throughout
fitting (concealed in plumbing walls and ceilings)
Tunnels
ACM TSI debris, at floor penetration (4"OD pipe Utility Tunnel L/M NW End
run)
ACM Army green/gray cable bracket mastic Utility Tunnel L/M, at tunnel Hatch
ACM Black asphaltic vapor barrier between Utility Tunnel A/B
concrete and wood forms
ACM TSI on abandon 8" pipe run Utility Tunnel A/B
JC on crawl space access door (3'x3') Block G Crawl Space
Exterior
ACM White caulking on steel columns Exterior Block L/M
ACM gray roll-up door frame caulking (8'x14') Exterior Block L
ACM tan/gray door frame caulking (8'x14') Exterior Block F
ACM tan window frame caulking (3'x5') Exterior Block F
ACM gray window frame caulking (3'x5') Exterior Block M
ACM black asphaltic tar beneath non-ACM black Block C Foundation
asphaltic felt on concrete foundation wall
Roof
ACM Silver coat on ACM black asphaltic tar on
metal roof vent base Block A Roof
ACM Silver coat on ACM asphaltic built up roofing
on non ACM asphaltic vapor barrier on non-ACM Block C Roof
brown paper vapor barrier on wood roof deck
ACM black asphaltic sealant on parapet wall Block D Roof
flashing
ACM Black asphaltic lead vent pipe penetration
sealant Block M Roof
ACM Silver coat on non-ACM built-up roofing on
non-ACM black asphaltic vapor barrier on non- Block M Roof
ACM asphaltic tar on concrete
ACM black asphaltic sealant on non-ACM black
asphaltic built-up roofing with tar beneath non- Block M Roof
ACM silver coat
ACM Black asphaltic tar on ACM built-up roofing
on non-ACM black asphaltic vapor barrier on
P1 Roof
non-ACM brown paper vapor barrier on wood
roof deck
ACM black asphaltic roof repair patch P1 Roof
Covered Walkways
I I
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL DESCRIPTION LOCATION
ACM Black asphaltic coating beneath non-ACM Center Courtyard
beige and white paint
Portables (P1)
ACM White wall cover backing Interior Walls
ACM gray window frame glazing putty (4'x8') Exterior Windows
and (3'x4')
Assumed ACM electrical panels and components Classroom
Assumed ACM chalkboard mastic Classroom
Community Pool
Non-ACM dark blue rubber flooring with non-
ACM white/beige mastic on tan VAT w/ ACM Office and Lobby 1
black mastic on concrete
ACM white cloth flex duct (4'x4') Boiler Room 2
ACM red seam sealant on ACM black sealant (on Boiler Room 3
AHU)
ACM silver paint on boiler exterior Boiler Room 4
ACM TSI on boiler exhaust duct (2'diameter) Boiler Room 5
ACM brown/black glue dots associated with fiber Office 6
board wall panel (4'x8')
ACM white cloth flex duct (3'x3') Men's and Women's Locker Room Attic 7
AHU with assumed ACM internal components Boiler Room 8
Assumed ACM electrical panels Boiler Room and Boiler Room Office 9
Assumed ACM fire doors Throughout
Assumed ACM flange gaskets (associated with the
boiler); Boiler Room
Assumed ACM boiler internal components Boiler Room
Assumed ACM wall panels and associated mastic
(High bay pool area); Over Pool
Assumed ACM TSI on small bore pipe runs and Throughout
fitting (concealed in plumbing walls and ceilings)
Assumed ACM TSI on large bore pipe runs and Under concrete slab
fittings under slab (associated with pool).
1.4 OPINIONS AND RECOMMENDATIONS
This will be a full demolition, therefore, EHSI recommends that all ACM and assumed ACM
identified in paragraph 1.3 be removed and disposed prior to demolition/renovation.
Any suspect materials not identified as having been surveyed in this report must be treated as
an ACM until determined otherwise by a Certified Asbestos Building Inspector and NVLAP
certified laboratory.
Washington State Department of Labor and Industries (L&I) Division of Occupational Safety
and Health (DOSH) and the US Occupational Safety and Health Administration (OSHA) require
•
e s .�
12
EHS-International,Inc.
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
employers to conduct a hazard assessment and take appropriate worker protection
precautions whenever building materials are disturbed that have detectable quantities of lead
and arsenic. Since the type of work planned (e.g., sawing, grinding, demolition) will disturb
the lead-containing paint, the contractor should perform an initial exposure assessment to
determine if personal protective measures and work practices are required. With the
exception of ceramic tile, porcelain bathroom fixtures and painted metal, based on the
relatively low concentrations of lead in the paint and absence of arsenic in the brick/CMU
mortar and the known scope of work (e.g., demolition), EHSI does not anticipate exposure
monitoring results will exceed the DOSH action level of 30 milligram per cubic meter (mg/m3)
for lead or 0.01 milligrams per cubic meter (mg/m3) for arsenic. Special care should be taken
to reduce potential employee exposure to lead when demolishing ceramic tile, porcelain
bathroom fixtures and painted metal, including reducing airborne dust (e.g., water misting
and use of hand tools, or demolition from a distance {backhoe}).
Fluorescent light fixtures within the scope of work have magnetic ballasts. Magnetic
fluorescent light ballasts that will be disturbed during the demolition project are assumed to
contain greater than two parts per million (> 2 ppm) PCB-dielectric oil and must be disposed
or recycled as Washington Department of Ecology (Ecology) Dangerous Waste. In addition,
all fluorescent tubes and lamps contain mercury. Any fluorescent lamps/tubes to be disturbed
during the project must be recycled as Washington Department of Ecology (Ecology)
Universal Waste.
1.5 LIMITATIONS/DISCLAIMER
This report does not represent a comprehensive hazardous materials investigation for the
subject property. This investigation has been conducted by EHSI under a specific scope of
work authorized by the FWSD for a specific purpose. Fire door cores, casework mastics,
chalk/cork/dry erase board, mirror and student locker mastics, enclosed plaster wall chases,
electrical panel components, boiler internals, and materials above hard lid ceilings were not
sampled and are assumed to be ACMs. This report and accompanying appendices include
the supporting information for this executive summary.
ehsi
EHS-International,Inc. 13
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
2.0 LIMITED HAZARDOUS MATERIALS SURVEY
REPORT
2.1 BACKGROUND
The Federal Way Public Schools District (District) plans to replace the existing Federal Way
High School with a new school on the same site. The District has contracted Greene
Gasaway Architects to manage this project and contracted the SRG Partnership (SRG) to
lead the design team. In conjunction with this project, the District contracted EHS-
International, Inc. (EHSI), a hazardous materials and environmental consulting firm, to
accomplish a pre-demolition limited hazardous materials survey of the existing structures on
the site, with the exception of playing fields and field houses, and to accomplish an
assessment of existing underground heating oil storage tanks (USTs) on the site. The UST
assessments will be provided under a separate cover. For the limited hazardous materials
survey, EHSI was tasked to use applicable federal, state, and local guidelines in the
accomplishment of its survey. EHSI was further tasked to provide a written survey report
including: identification of all suspect materials; a determination of whether suspect
materials were: asbestos-containing materials (ACM), lead-containing paint (LCP), lead-
containing materials (LCM), Arsenic (As)-containing brick/concrete masonry unit (CMU)
mortar, polychlorinated biphenyl (PCB)-containing light ballasts and transformers, or
Mercury (Hg)-containing light tubes/lamps, thermostats and switches; and to provide
analytical reports indicating the presence and quantity of the hazardous materials.
This Limited Hazardous Materials Survey Report meets the Washington State "Good Faith
Survey" requirements as cited in Revised Code of Washington (RCW) 49.26.016 and
implemented by Department of Labor and Industries Division of Occupational Safety and
Health (L&I DOSH) regulation, Washington Administrative Code (WAC) 296-62-07721, and
Regulation III, Article 4 of the Puget Sound Clean Air Agency (PSCAA).
On April 1st - 19th and June 25th, 2013, EHSI conducted a Limited Hazardous Materials
(ACM, LCP, LCM, As, PCB or Hg-containing) Survey of wings A through M, including roofs,
attics, crawlspaces, basements and covered walkways; two portable classroom buildings P1
& P2; and the "Community Pool" building on the Federal Way High School campus.
2.2 BUILDING DESCRIPTION
The Federal Way High School is located at 30611-16th Avenue South, Federal Way,
Washington. The original building was constructed in 1937 with additions, modernization
projects and new building construction in 1944, 1952, 1957, 1962, 1972, 1975, 1985, and
2001.
The original 1937 (Block C) Building is a two-story structure constructed of brick masonry
units (BMU) on a concrete foundation with wood framed interior walls. The roof is a sloped
three-tab roof on wood decking. Interior walls include: plaster and GWB walls (the GWB
walls have replaced original plaster walls located throughout the 1st and 2nd floor library).
Other interior finishes include: vinyl or wood cove base (CB) throughout. Flooring includes:
Vinyl composite tiles (VCT) and vinyl asbestos tiles (VAT) on black mastic on wood and
concrete. Ceilings include: Plaster "hard-lid" and GWB "hard-lid", suspended acoustic ceiling
tiles and acoustic tiles glued onto GWB. Windows are operable and non-operable metal-
ehsi4
14
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
framed. In 1944, a two-story structure was added to the original building consisting of the
same building materials. A natural gas boiler located in the 1st floor boiler room provides hot
water to this block. A central HVAC system located in the attic space provides forced air
heating and air conditioning.
The 1952 (Block A/B) Building is a one-story structure constructed of concrete and concrete
masonry units (CMU) on concrete foundation. The building houses the main gym, auxiliary
gym, locker rooms and cafeteria. In 1965, the building went through renovations adding
another locker room and a second floor exercise room. In 2001, Block B went through a
renovation adding a commons area to the cafeteria. The roof is flat with the exception of the
main gym roof which is gambrel roof, all on wood decking. Interior walls include: CMU,
plaster, GWB and ceramic wall tile walls. Other interior finishes include: vinyl cove base.
Flooring includes: bare and painted concrete, 12"x12" VCT, 9"x9" VAT, ceramic tiles, hard
wood flooring, carpet, carpet on VCT/VAT and concrete. Ceilings include: Plaster "hard-lid",
GWB "hard-lid", acoustical ceiling tiles (ACT) glued-on GWB, and suspended acoustic ceiling
tiles (SACT). There is spray applied fireproofing on structural elements above the ceilings.
Clearstory windows provide light in the main gym and fluorescent fixtures provide light
throughout the rest of the building. A natural gas boiler located in a boiler room below grade
provides hot water to these two blocks. A central HVAC system provides forced air heating
and air conditioning.
Block L/M Building was originally constructed in 1957 and renovated in 1971 and 1975. The
building is a one-story structure housing industrial arts and sciences classrooms/labs.
Exterior walls are made of BMU, CMU and concrete, all on a concrete foundation. The roof
is slightly sloped on wood decking. Interior wall finishes include: BMU GWB, and plaster
walls. Other interior finishes include: vinyl CB throughout. Flooring includes: 12"x12" VCT,
9"x9" VAT, carpet on 9"x9" VAT, carpet on 12"x12" VCT, and carpet on concrete. Ceilings
include: GWB "hard-lid", mechanically fastened 1'x1' ACT on GWB "hard-lid" above SACT.
Windows are metal framed and operable. A natural gas boiler located in a mechanical room
provides hot water to these two blocks. A central HVAC system provides forced air heating
and air conditioning.
Block D was originally constructed in 1958 and renovated in 1972 and is a one-story
structure encompassing the library and classrooms. Exterior walls are made of BMU on a
concrete foundation. The roof is slightly sloped on wood decking. Interior wall finishes
include: BMU, GWB, and plaster. Other interior finishes include: vinyl CB throughout.
Flooring includes: 12"x12" VCT, 9"x9" VAT, carpet on 9"x9" VAT, carpet on 12"x12" VCT,
and carpet on concrete. Ceilings include: GWB "hard-lid", mechanically fastened and glued-
on 1'x1' ACT on GWB "hard-lid" above SACT. Windows are operable metal framed windows.
A natural gas boiler located in a mechanical room provides hot water to this block. A central
HVAC system provides forced air heating and air conditioning.
Block E, F, J and K were originally constructed in 1962 and renovated in 1972, 1975 and
2001. The building is a one-story structure housing the theatre and class rooms. Exterior
walls are made of BMU and CMU on a concrete foundation. The roof is sloped with 3-tab
composite shingles on wood decking. Interior wall finishes include: BMU, GWB, and plaster.
Other interior finishes include: vinyl CB throughout. Flooring includes: 12"x12" VCT, 9"x9"
VAT, carpet on 9"x9" VAT, carpet on 12"x12" VCT, and carpet on concrete. Ceilings include:
GWB "hard-lid", mechanically fastened and glued-on 1'x1' ACT on GWB "hard-lid" above
SACT. Lighting is provided by fluorescent fixtures along with operable metal framed
windows. A natural gas boiler located in a mechanical room provides hot water to these
ehsi.) IS
EHS-International,Inc.
• • ,
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
blocks and Blocks G and H. A central HVAC system provides forced air heating and air
conditioning.
Block G was originally constructed in 1972 and is a one-story structure housing classrooms.
Exterior walls are made of BMU on a concrete foundation. The roof is sloped with 3-tab
composite shingles on wood decking. Interior wall finishes include: GWB, and plaster walls.
Other interior finishes include: vinyl CB throughout. Flooring includes: 12"x12" VCT, 9"x9"
VAT, carpet on 9"x9" VAT, carpet on 12"x12"VCT, and carpet on concrete. Ceilings include:
GWB and plaster "hard-lid", mechanically fastened and glued-on 1'x1' ACT on GWB "hard-
lid" above SACT. Windows are operable metal framed. A natural gas boiler located in a
mechanical room located in block F provides hot water to this block. A central HVAC system
provides forced air heating and air conditioning.
Block H was originally constructed in 1985 and is a one-story structure housing classrooms.
Exterior walls are made of BMU on a concrete foundation. The roof is sloped with 3-tab
composite shingles on wood decking. Interior wall finishes include: GWB, and plaster walls.
Other interior finishes include: vinyl CB throughout. Flooring includes: 12"x12" VCT, 9"x9"
VAT, carpet on 9"x9" VAT, carpet on 12"x12"VCT, and carpet on concrete. Ceilings include:
GWB and plaster "hard-lid", mechanically fastened and glued-on 1'x1' ACT on GWB "hard-
lid" above SACT. Windows are operable metal framed. A natural gas boiler located in a
mechanical room located in block F provides hot water to this block. A central HVAC system
provides forced air heating and air conditioning.
Portable 1 is a wood-framed, single classroom portable. The roof is flat and exterior walls
are made of wood siding. Interior finishes include: cloth covered GWB walls, vinyl CB
throughout, and 12"x12" VCT on wood. Lighting is provided by fluorescent light fixtures and
metal framed operable windows. Heat is provided by an electric furnace.
Portable 2 is a wood-framed, 2 classroom portable. The roof is sloped with 3-tab composite
shingles and exterior walls are made of wood siding. Interior finishes include: cloth covered
GWB walls, vinyl CB throughout, and carpet on wood. Lighting is provided by fluorescent
light fixtures and metal framed operable windows. Heat is provided by an electric furnace.
The Community Pool is a single-story brick structure, constructed in 1971. The roof is
sloped with 3-tab composite shingles on wood decking. Interior finishes include: ceramic
floor tiles, carpet, VAT and VCT on concrete and bare concrete. Interior walls are made of
GWB and some are covered with ceramic wall tiles and fibrous panels. Lighting is provided
by fluorescent light fixtures. Heating for the building and the pool is provided by a natural
gas boiler located in the mechanical room.
2.3 SAMPLING METHODOLOGY
2.3.1 Asbestos-Containing Materials
The EHSI field inspectors are asbestos Building Inspectors, certified under the requirements
of the United States Environmental Protection Agency (USEPA) AHERA regulation 40 Code of
Federal Regulations (CFR) 763, Subpart E. Copies of their certificates are provided in
Appendix C. The number of bulk samples collected and their locations are based on the
AHERA regulation and the guidelines provided by the USEPA Document 560/5-85-030a,
ehS/i►,
EHS-International.Inc. 16
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
October 1985, Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing
Materials.
EHSI collected samples and obtained analytical data for suspect ACM identified in the
facility. Once collected, each bulk sample was sealed in an unadulterated plastic bag to
eliminate the possibility of cross-contamination. "Chain-of-Custody" tracking was followed to
maintain sample integrity during handling and data reporting at EHSI and the analytical
laboratory. As specified in 40 CFR Chapter 1 (1-1-87 edition) Part 763, Subpart F, and
Appendix A, each sample was analyzed using polarized light microscopy (PLM) / dispersion
staining techniques, in accordance with USEPA Method 600/R-93/116. Samples were
analyzed for asbestos content by Seattle Asbestos Test, LLC (SAT) located in Bellevue,
Washington. SAT participates in the NVLAP. Only materials containing more than 1% total
asbestos were classified as "asbestos-containing" based on USEPA, state, and local
regulations.
Samples in the report labeled as ##QA are quality assurance (QA) samples. Split samples
were taken from the same location and they were sent to separate laboratories. QA
samples were submitted to, NVL Laboratories, Inc. (NVL) in Seattle, WA, another NVLAP
laboratory. Copies of both laboratories' NVLAP certifications are included in Appendix D.
2.3.2 Lead-Containing Paint/Lead-Containing Materials
EHSI used a Niton Model XLp x-ray fluorescence (XRF) Spectrum Analyzer to measure lead
content on interior and exterior paint coatings and other suspect LCM. Measurements were
representative of all layers of paint and/or LCM. A summary of Lead Paint XRF results is
provided in Appendix B. Bulk quality assurance samples were taken for a representative
number of LBP and LCM and were sent to NVL located in Seattle, Washington, an accredited
laboratory for Atomic Absorption Spectroscopy (USEPA Method-7000B) by the American
Industrial Hygiene Association (AIHA) under the Environmental Lead Laboratory
Accreditation Program (ELLAP). Copies of laboratory reports and field data forms for lead
are in Appendix B.
2.3.3 Arsenic-Containing Materials
EHSI collected samples and obtained analytical data for CMU and BMU mortar from the
interior and exterior of the facility. Once collected, each bulk sample was sealed in an
unadulterated plastic bag to eliminate the possibility of cross-contamination. "Chain-of-
Custody" tracking was followed to maintain sample integrity during handling and data
reporting at EHSI and the analytical laboratory. A summary of Arsenic laboratory results is
provided in Table 4. Samples were sent to NVL, an accredited laboratory for Inductively
Coupled Plasma Spectroscopy (USEPA Method-6010) by the Washington State Department
of Ecology. Copies of laboratory reports and field data forms for Arsenic are in Appendix B.
2.4 SAMPLING RESULTS
2.4.1 Asbestos-Containing Materials
Eight hundred three (803) bulk samples of suspect ACM were collected as part of the
survey. Forty (40) of those samples were split for quality assurance analyses. Limited
destructive inspection was conducted to identify hidden and/or concealed materials. Copies
ehsi
EHS-International,Inc. 17
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
of the asbestos analytical laboratory results are included in Appendix A. Asbestos, lead and
arsenic sample location drawings are provided in Appendix E. Asbestos sampling
information including: sample number, material description, sample location, and analytical
results are summarized in Table 1. The ACM and assumed ACM identified during this
survey, including the quantity and location, is summarized in Table 2. Suspect materials
not sampled were assumed to be ACM.
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
BLOCK A
Layer 1: 4" Beige/gray L1: ND N/A
Al - Auxiliary Gym cove base
10527-A-01 Layer 2: Tan mastic L2: ND N/A
- South Wall Layer 3: White/beige L3: ND N/A
paint
Layer 1: Gray seam L1: ND N/A
Al - Auxiliary Gym caulking w/paint on
10527-A-02 - South Wall concrete wall
Layer 2: Yellow foam L2: ND N/A
insulation
Al - Auxiliary Gym Layer 1: JC w/ paint L1: ND N/A
10527-A-03 - Southwest (corner)
Corner Layer 2: GWB w/ paper L2: ND N/A
Al - Auxiliary Gym Layer 1: JC w/ paint (mid L1: ND N/A
10527-A-04 - Southwest wall)
Corner Layer 2: GWB w/ paper L2: ND N/A
Al Auxiliary Gym Layer 1: JC w/ paint (mid Li: ND N/A
10527 A 05wall)
- Southeast Corner
Layer 2: GWB w/ paper L2: ND N/A
Al - Auxiliary Layer 1: l'xl' White ACT L1: ND N/A
10527-A-06 w/paint
Gym Corridor A35
Layer 2: Brown mastic L2: ND N/A
10527-A-07 Al - Auxiliary Gym Layer 1: JC L1: ND N/A
Corridor A35 Layer 2: GWB, at seam L2: ND N/A
10527-A-08 Al Auxiliary Gym Tan pipe dope ND N/A
Corridor A35
Layer 1: 12"x12" Off- L1: ND N/A
Al Auxiliary Gym White VCT w/ brown and
10527-A-09 Corridor A35 white streaks
Layer 2: Yellow mastic L2: ND N/A
Layer 3: Concrete L3: ND N/A
Layer 1: Skim coat w/ L1: ND N/A
10527-A-10 A2 - Weight Room paint
South Wall Layer 2: GWB w/ paper L2: ND N/A
(corner)
ehsi•,
18
EHS-International,Inc.
• • •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Skim coat w/ L1: ND N/A
10527-A-11 A2 - Weight Room paint
South Wall Layer 2: GWB w/ paper L2: ND N/A
(mid wall)
Layer 1: Skim coat w/ L1: ND N/A
10527-A-12 A2 - Weight Room paint
South Wall Layer 2: GWB w/ paper L2: ND N/A
(mid wall)
Layer 1: 4" Black cove L1: ND N/A
A2 - Weight Room base
10527-A-13 Northeast Corner Layer 2: Cream colored L2: ND N/A
mastic
Layer 3: White paint L3: ND N/A
Layer 1: Blue carpet L1: ND N/A
10527-A-14 A2 - Weight Room Layer 2: Gray carpet foam L2: ND N/A
Layer 3: Yellow mastic L3: ND N/A
Layer 1: 2'x4' SACT w/ L1: ND N/A
10527-A-15 A2 - Corridor A46 foil and mastic
Layer 2: Gray 2'x4' SACT L2: ND N/A
Layer 1: 6"X6" L1: ND N/A
Orange/brown ceramic
10527-A-16 A2 - A50 Lockers cove base tiles
Layer 2: Gray grout L2: ND N/A
Layer 3: Gray mortar L3: ND N/A
Layer 1: 1" & 2" L1: ND N/A
Brown/orange ceramic
10527-A-17 A2 - A50 Lockers floor tile
Layer 2: Gray grout L2: ND N/A
Layer 3: Black/gray L3: ND N/A
mortar
10527-A-18 A2 - A50 Lockers Black speaker coating ND N/A
w/white paint
10527-A- Layer 1: Beige paint L1: ND N/A
19QA A2 - A50 Lockers Layer 2: White skim coat L2: ND N/A
Layer 3: Plaster L3: ND N/A
Layer 1: Beige paint L1: ND N/A
10527-A-20 A2 - A50 Storage Layer 2: White skim coat L2: ND N/A
Layer 3: Plaster L3: ND N/A
Layer 1: White Paint L1: ND N/A
10527-A-21 A2 - A55 Shower Layer 2: Silver Paint L2: ND N/A
Layer 3: Plaster L3: ND N/A
Layer 1: White Paint L1: ND N/A
10527-A-22 A2 - A55 Shower Layer 2: Silver Paint L2: ND N/A
Layer 3: Plaster L3: ND N/A
ehsi 4► 19
EHS-International,Inc.
• i
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: White Paint Li: ND N/A
10527-A-23 A2 - A56 Entry Layer 2: White skim coat L2: ND N/A
Layer 3: Plaster L3: ND N/A
Layer 1: White Paint L1: ND N/A
10527-A-24 A2 - A62 Shower Layer 2: Silver Paint L2: ND N/A
Layer 3: Plaster L3: ND N/A
Layer 1: Beige Paint L1: ND N/A
10527-A-25 A2 - A60 Lockers Layer 2: White skim coat L2: ND N/A
Layer 3: Plaster L3: ND N/A
Layer 1: Beige Paint L1: ND N/A
10527-A-26 A2 - A60 Lockers Layer 2: White skim coat L2: ND N/A
Layer 3: Plaster L3: ND N/A
L1: 20% Chrysotile
Layer 1: Black asphaltic
built up roofing
A2 -Interstitial Layer 2: Black asphaltic L2: 21% Chrysotile
10527-A-27 Space between built up roofing
1St and 2"d Floor Layer 3: Brown fibrous
insulation L3: ND N/A
Layer 4: Black asphaltic
vapor barrier L4: 21% Chrysotile
L1: 20% Chrysotile
Layer 1: Black asphaltic
built up roofing L2: ND N/A
Layer 2: Black asphaltic
built up roofing L3: 23% Chrysotile
Layer 3: Black asphaltic
built up roofing L4: 20% Chrysotile
Layer 4: Black asphaltic
vapor barrier
A2 -Interstitial L5: 22% Chrysotile
10527-A-28 Space between Layer 5: Black asphaltic
1St and 2nd Floor built up roofing
Layer 6: Black asphaltic L6: 22% Chrysotile
built up roofing
Layer 7: Black asphaltic
built up roofing L7: 21% Chrysotile
Layer 8: Brown fibrous
insulation 3
Layer 9: Black asphaltic L8: ND N/A
vapor barrier
L9: 20% Chrysotile
EHS-International,Inc.
20
i i
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
A2 - Interstitial Gray light weight concrete
10527-A-29 Space between 1stat roof edge
ND N/A
and 2nd Floor g
Layer 1: 4" White ceramic L1: ND N/A
10527-A- wall tiles
30QA A2 - A59 Toilet Layer 2: White grout L2: ND N/A
Layer 3: Tan mastic w/ L3: ND N/A
paint
Layer 1: 1" Gray ceramic L1: ND N/A
wall tile
Layer 2: Gray grout L2: ND N/A
10527-A-31 A2 - A59 Toilet Layer 3: Gray mortar L3: ND N/A
Layer 4: Yellow mastic L4: ND N/A
Layer 5: Trace amount of L5: ND N/A
concrete
Layer 1: JC w/ paint L1: ND N/A
10527-A-32 A2 - A50 Lockers Layer 2: GWB w/ paper, L2: ND N/A
at edge of soffit
Layer 1: JC w./ paint L1: ND N/A
10527-A-33 A2 - A60 Lockers Layer 2: GWB w/ paper, L2: ND N/A
at middle of soffit
Layer 1: JC w./ paint Li: ND N/A
10527-A-34 A2 - A60 Lockers Layer 2: GWB w/ paper, L2: ND N/A
at middle of ceiling
Layer 1: JC w./ paint L1: ND N/A
10527-A-35 A2 - A50 Lockers Layer 2: GWB w/ paper, L2: ND N/A
at middle of ceiling
Layer 1: JC w./ paint Li: ND N/A
10527-A-36 A2 - A50 Lockers Layer 2: GWB w/ paper, L2: ND N/A
at ceiling edge
2'x4' White SACT w/ pin
10527-A-37 A2 - A57 Office hole and worm track ND N/A
pattern w/paint
10527-A-38 A2 - A50 Lockers White sink undercoat ND N/A
Layer 1: Beige carpet L1: ND N/A
10527-A-39 A2 - A50 Entry backing
Layer 2: Yellow mastic L2: ND N/A
Layer 3: Tan/gray mastic L3: ND N/A
10527-A-40 A2 - A50 Entry White door frame caulking ND N/A
w/paint
Layer 1: 12"x12" Off- L1: ND N/A
10527-A-41 A2 - A52 Storage white VCT w/ brown,
yellow and white specks
Layer 2: Black mastic L2: ND N/A
ehsi
EHS-International,Inc. 21
i •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Yellow VCT L1: ND N/A
mastic
10527-A- A2 - A66 Layer 2: Gray leveling L2: ND N/A
42QAx Corridor compound
Layer 3: Residual black L3: 3% Chrysotile
mastic
Layer 1: Yellow mastic L1: ND N/A
(associated w/ VCT)
10527-A-43 A2 - A71 Corridor Layer 2: White leveling L2: ND N/A
compound
Layer 3: Black mastic L3: ND N/A
Layer 1: 6"x6" Red L1: ND N/A
10527-A-44 A2 - A70 Janitor ceramic floor tile
Layer 2: Gray grout L2: ND N/A
Layer 3: Gray mortar L3: ND N/A
10527-A-45 A2 - A70 Janitor Black asphaltic sealant ND N/A
around floor drain
Layer 1: White paint L1: ND N/A
A2 A72 Men's Layer 2: 2'x4' textured L2: ND N/A
10527-A-46 ACT
Room Layer 3: 1'x1' White ACT L3: ND N/A
Layer 4: Brown glue dot L4: ND N/A
Layer 1: Brown stair L1: 2% Chrysotile
tread
10527-A-47 A2 - Stair 1 Layer 2: Green mastic L2: ND N/A
Layer 3: Brown/yellow L3: ND N/A
mastic with JC
Layer 1: Brown SVF L1: 2% Chrysotile
10527-A-48 A2 - Stair 1 Layer 2: Yellow mastic on L2: ND N/A
wood
Layer 1: 8" Brown vinyl L1: 2% Chrysotile
cove base/stair
10527-A-49 A2 - Stair 1 stringer
Layer 2: Brown mastic on L2: ND N/A
wood
Layer 1: 4" Brown cove L1: ND N/A
base
10527-A-50 A4 - A4-3 Exercise Layer 2: Cream colored L2: ND N/A
mastic
Layer 3: Tan/brown L3: ND N/A
mastic
Layer 1: 4"Tan/beige L1: ND N/A
10527-A-51 A4 - A4-3 Exercise cove base
Layer 2: Cream colored L2: ND N/A
mastic
ehsi.4.0
22
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Dark brown/gray L1: ND N/A
10527-A-52 A4 - A4-3 Exercise glue dot
Layer 2: Tan wood debris L2: ND N/A
Layer 1: White skim coat L1: ND N/A
10527-A-53 A4 - A4-3 Exercise w/ paint
Layer 2: White GWB w/ L2: ND N/A
paper (mid wall)
Layer 1: White skim coat L1: ND N/A
10527-A-54 A4 - A4-3 Exercise w/ paint
Layer 2: White GWB w/ L2: ND N/A
paper (mid wall)
Layer 1: White skim coat L1: ND N/A
10527-A-55 A4 - A4-3 Exercise w/ paint
Layer 2: White GWB w/ L2: ND N/A
paper (mid wall)
Layer 1: White skim coat L1: ND N/A
10527-A-56 A4 - A4-3 Exercise w/ paint
Layer 2: White GWB w/ L2: ND N/A
paper (mid wall)
Layer 1: White skim coat L1: ND N/A
10527-A-57 A4 - A4-3 Exercise w/ paint
Layer 2: White GWB w/ L2: ND N/A
paper (mid wall)
10527-A-58 A4 - A4-2 Exercise Black flex duct w/ black ND N/A
caulking w/paint
10527-A-59 A4 - A4-2 Exercise Tan pipe dope ND N/A
Layer 1: 1'x1' White ACT L1: ND N/A
10527-A-60 A4 - A4-2 Exercise w/ pin hole pattern
Layer 2: Brown mastic L2: ND N/A
10527-A-61 Al-A2 Gymnasium TectumT" panel w/yellow ND N/A
mastic
Layer 1: White skim coat L1: ND N/A
10527-A-62 Al-A2 Gymnasium w/ paint
Layer 2: GWB w/ paper L2: ND N/A
(mid wall)
Layer 1: White skim coat L1: ND N/A
10527-A-63 Al-A2 Gymnasium w/ paint
Layer 2: GWB w/ paper L2: ND N/A
(corner)
Al -Girls Locker Layer 1: White skim coat L1: 0.5% N/A
10527-A-64`1 Room A15 Office Layer 2: Pink GWB w/ L2: ND N/A
paper (ceiling edge)
ehsi423
EHS-International,Inc.
. •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: White skim coat L1: 0.75% N/A
10527-A-65*' Al -Girls Locker w/ paint
Room A15 Office Layer 2: Pink GWB w/ L2: ND N/A
paper (mid ceiling)
Layer 1: White skim coat L1: ND N/A
Al - Girls Locker w/ paint and powdery
10527-A-66 Room A10 Lockers material
Layer 2: GWB w/ paper L2: ND N/A
(ceiling edge)
Layer 1: White skim coat L1: ND N/A
10527-A-67 Al - Girls Locker w/ paint
Room A10 Lockers Layer 2: GWB w/ paper L2: ND N/A
(mid ceiling)
Layer 1: White skim coat L1: ND N/A
10527-A-68 Al - Girls Locker w/ paint
Room A24 Lockers Layer 2: GWB w/ paper L2: ND N/A
(mid soffit)
10527-A-69 Al - Girls Locker Layer 1; White paint L1: ND N/A
Room Al2 Shower Layer 2: Plaster (ceiling) L2: ND N/A
10527-A-70 Al - Girls Locker Layer 1; White paint L1: ND N/A
Room Al2 Shower Layer 2: Plaster (ceiling) L2: ND N/A
Al - Girls Locker Layer 1: Gray paint L1: ND N/A
10527-A-71 Room A22 Shower Layer 2: Gray plaster L2: ND N/A
(ceiling)
Layer 1: 1"xl" Brown L1: ND N/A
Al Girls Locker ceramic floor tiles
10527-A-72 Layer 2: Gray grout L2: ND N/A
Room A6 Storage Layer 3: Beige mastic L3: ND N/A
Layer 4: Gray mortar L4: ND N/A
10527-A-73 Al Girls Locker Gray duct seam sealant ND N/A
Room A6 Storage
10527-A-74 Al - Girls Locker Black window glazing ND N/A
Room A10 Lockers putty w/paint and mastic
Al Girls Locker Layer 1: White window L1: ND N/A
10527-A-75 Room A10 Lockers frame caulking w/ paint
Layer 2: Concrete debris L2: ND N/A
10527-A-76 Al - Girls Locker Residual black mastic on ND N/A
Room A6 Storage concrete
Layer 1: 4"x4" White L1: ND N/A
10527-A-77 Al- Girls Locker ceramic wall tile
Room A25 Toilet Layer 2: White grout L2: ND N/A
Layer 3: Tan mastic L3: ND N/A
ehsi
24
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: 1"xl" Gray L1: ND N/A
ceramic L2: ND N/A
Al - Girls Locker Layer 2: Gray grout L3: ND N/A
10527-A-78 Room A17 Dress Layer 3: Yellow mastic L4: ND N/A
Layer 4: Dark gray mortar
Layer 5: Gray light weight L5: ND N/A
concrete
A2 - Mechanical Beige duct edge
10527-A-79 Area above A38 caulking/sealant (by flex ND N/A
Training ducts)
A2 Mechanical Beige duct seam sealant
10527-A-80 Area above A38 ND N/A
(at duct flanges)
Training
A2 Mechanical Gray duct seam sealant
10527-A-81 Area above A38 ND N/A
(at duct flanges)
Training
A2 Mechanical Yellow/tan duct seam
10527-A-82 Area above A38 ND N/A
sealant
Training
A2 - Mechanical Layer 1: Black material L1: ND N/A
10527-A-83 Area above A38 Layer 2: Concrete debris L2: ND N/A
Training Layer 3: Wood debris L3: ND N/A
10527-A-84 A2 - A38 Training Off-white sink undercoat ND N/A
A2 - Mechanical Layer 1: White skim coat L1: ND N/A
10527-A-85 Area above A38 w/ paint
Training Layer 2: Plaster wall L2: ND N/A
A2 - Mechanical Layer 1: White skim coat L1: ND N/A
10527-A-86 Area above A38 w/ paint
Training Layer 2: Plaster wall L2: ND N/A
A2 - Mechanical Layer 1: White skim coat L1: ND N/A
10527-A-87 Area above A38 w/ paint
Training Layer 2: Plaster wall L2: ND N/A
Layer 1: Yellow carpet Ll: ND N/A
mastic
10527-A- A2 - A75 Layer 2: 9"x9" Burnt L2: 4% Chrysotile
88QAx Marketing orange VAT
Layer 3: Black mastic on L3: ND N/A
concrete
ehsi 4
25
EHS-International,Inc.
• . .
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Yellow carpet L1: ND N/A
mastic
Layer 2: Gray leveling L2: ND N/A
10527-A-89 A2 - A76 compound
Marketing Layer 3: 9"x9" Burnt L3: 3% Chrysotile
orange VAT
Layer 4: Black mastic on L4: ND N/A
concrete
10527-A-90 A2 - A4-4 Green/dark gray duct ND N/A
Mechanical seam sealant
10527-A-91 A2 - A4-4 Gray louver frame ND N/A
Mechanical caulking
10527-A-92 A2 - A4-4 White conduit penetration ND N/A
Mechanical sealant
10527-A- Al - A3 Student Layer 1: l'xl' White ACT L1: ND N/A
93QA Store Layer 2: Brown glue dot L2: ND N/A
Layer 1: 12"x12" Light L1:ND N/A
gray VCT
10527-A-94 Al - A2 Commons Layer 2: Yellow mastic L2: ND N/A
Layer 3: Black mastic on L3: ND N/A
concrete
Layer 1: 12"x12" Blue L1: ND N/A
VCT
10527-A-95 A2 - A74 Corridor Layer 2: Yellow mastic L2: ND N/A
Layer 3: Black mastic on L3: ND N/A
concrete
Layer 1: Blue carpet L1: ND N/A
Layer 2: Yellow mastic L2: ND N/A
10527-A-96 Al - A5 ASB Layer 3: Gray leveling L3: ND N/A
compound
Layer 4: Residual black L4: 3% Chrysotile
mastic on concrete
A2 - Basement
10527-A-97 Mechanical Room Tan pipe dope ND N/A
01
A2 - Basement
10527-A-98 Mechanical Room Red flange gasket ND N/A
01
A2 - Basement Black penetration sealant
10527-A-99 Mechanical Room on boiler flue ND N/A
01
A2 - Basement White penetration sealant
10527-A-100 Mechanical Room on boiler flue ND N/A
01
ehsi��►
EHS-International,Inc. 26
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
A2 - Basement
10527-A- Black fibrous vapor barrier
101QA
Mechanical Room (in ceiling penetration) ND N/A
A2 - Basement Black asphaltic tar (in
10527-A-102 Mechanical Room ceiling penetration) ND N/A
01
A2 - Basement White coating on ceiling
10527-A-103 Mechanical Room panels ND N/A
01
A2 - Basement Layer 1: Brown cork L1: ND N/A
10527-A-104 Mechanical Room ceiling panel
01 Layer 2: White coating L2: ND N/A
Layer 3: Concrete debris L3: ND N/A
A2 - Basement Layer 1: JC w/ paint L1: ND N/A
10527-A-105 Mechanical Room Layer 2: GWB w/ paper L2: ND N/A
01 (corner)
A2 - Basement Layer 1: JC w/ paint L1: ND N/A
10527-A-106 Mechanical Room Layer 2: GWB w/ paper L2: ND N/A
01 (mid wall)
A2 - Basement Layer 1: JC w/ paint L1: ND N/A
10527-A-107 Mechanical Room Layer 2: GWB w/ paper L2: ND N/A
01 Generator (mid wall)
Room
A2 - Basement Layer 1: Black seam L1: ND N/A
10527-A-108 Mechanical Room sealant (on nail
01 Generator penetrations)
Room Layer 2: Sand debris L2: ND N/A
A2 - Basement Black/gray seam sealant
10527-A-109 Mechanical (on generator exhaust ND N/A
Exterior Enclosure unit)
A2 Basement Black seam sealant(on
10527-A-110 Mechanical generator exhaust unit) ND N/A
Exterior Enclosure
Layer 1: Light pink L1: ND N/A
10527-A-111 Al - Main fireproofing w/ trace
Gymnasium mastic
Layer 2: Wood debris L2: ND N/A
10527-A-112 Al - Main Light pink fireproofing w/ ND N/A
Gymnasium mastic
Al - Main Layer 1: Light pink Li: ND N/A
10527-A-113 Gymnasium fireproofing w/ mastic
Layer 2: Wood debris L2: ND N/A
Al - Main Layer 1: Light pink Li: ND N/A
10527-A-114 Gymnasium fireproofing w/ mastic
Layer 2: Wood debris L2: ND N/A
ehs .,
EHS-International,Inc. 27
. •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Light pink L1: ND N/A
Al - A34 Aux fireproofing
10527-A-115 Layer 2: JC w/ paper L2: ND N/A
Gymnasium Layer 3: GWB w/ paper L3: ND N/A
(at seam)
Layer 1: Light pink L1: ND N/A
10527-A-116 Al - A34 Aux fireproofing
Gymnasium Layer 2: GWB w/ paper L2: ND N/A
(ceiling)
Layer 1: Light pink L1: ND N/A
10527-A-117 Al - A34 Aux fireproofing
Gymnasium Layer 2: GWB w/ paper L2: ND N/A
(ceiling)
Layer 1: Brown vapor L1: ND N/A
barrier w/ black asphaltic
backing
10527-A- Al - Main Layer 2: Hardwood floor L2: ND N/A
118 Gymnasium sleepers
Layer 3: Black asphaltic L3:21% Chrysotile
vapor barrier tarred to
concrete
Layer 1: Hard wood L1: ND N/A
flooring
Layer 2: Brown vapor L2: ND N/A
barrier w/ black asphaltic
backing
10527-A- Al - Main Layer 3: Hardwood floor L3: ND N/A
119 Gymnasium sleepers
Layer 4: Multi-layered L4: 19% Chrysotile
black asphaltic vapor
barrier
Layer 5: Black asphaltic L5: ND N/A
tar on concrete
Layer 1: Hardwood L1: ND N/A
flooring
Layer 2: Brown vapor L2: ND N/A
barrier w/ black asphaltic
10527-A- Al - Main backing
120 Gymnasium Layer 3: Hardwood floor L3: ND N/A
sleepers
Layer 4: Black asphaltic L4: 20% Chrysotile
vapor barrier on
concrete
10527-A-121 A2 - A34 Aux Brown hard wood flooring ND N/A
Gymnasium w/ concrete debris
ehs14
ENS-International,Inc. 28
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
BLOCK B
10527-B-01 2001 Era Cafeteria Light gray door/window ND N/A
frame caulking
Layer 1: 4"Tan/gray cove L1: ND N/A
10527-B-02 2001 Era Cafeteria base
Layer 2: Cream colored L2: ND N/A
mastic
10527-B-03 2001 Era Cafeteria White plaster w/ paint on ND N/A
wall
10527-B-04 2001 Era Cafeteria White plaster w/ paint on ND N/A
wall
10527-B-05 2001 Era Cafeteria White plaster w/ paint on ND N/A
wall
Layer 1: 12"x12" Light L1: ND N/A
gray VCT
10527-B-06 2001 Era Cafeteria Layer 2: Yellow mastic L2: ND N/A
Layer 3: Gray leveling L3: ND N/A
compound on concrete
Layer 1: Tan/ white L1: ND N/A
10527-B-07 2001 Era Cafeteria fibrous wall panel w/ paint
Layer 2: Black mastic on L2: ND N/A
concrete
Layer 1: 12"x12" Blue L1: ND N/A
10527-B- VCT
08QAX B1/B2 Cafeteria Layer 2: Yellow mastic L2: ND N/A
Layer 3: Residual black L3: 2% Chrysotile
mastic on concrete
10527-B-09 B2 Cafeteria Gray door frame caulking ND N/A
w/ paint and JC
Layer 1: White skim coat L1: ND N/A
10527-B-10 B2 Cafeteria Wall w/ paint
Layer 2: GWB w/ paper L2: ND N/A
Layer 1: White skim coat L1: ND N/A
10527-B-11 B2 Cafeteria Wall w/ paint
Layer 2: GWB w/ paper L2: ND N/A
Cafeteria B6 Entry Layer 1: White skim coat L1: ND N/A
10527-B-12 Wall w/ paint
Layer 2: GWB w/ paper L2: ND N/A
Layer 1: White skim coat L1: ND N/A
10527-B-13 B2 Cafeteria Wall w/ paint
Layer 2: GWB w/ paper L2: ND N/A
Layer 1: White skim coat L1: ND N/A
10527-B-14 B3 Cafeteria Wall w/ paint
Layer 2: GWB w/ paper L2: ND N/A
e si.►
EHS-International,Inc. 29
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
10527-B-15 B1 Cafeteria 2'x4' SACT w/ pin hole ND N/A
and worm track pattern
Layer 1: 1'x1' White ACT L1: ND N/A
10527-B-16 B1 Cafeteria w/ large hole pattern
Layer 2: Brown glue dot L2: ND N/A
Layer 1: 6" Red ceramic L1: ND N/A
10527-B-17 B9 Kitchen quarry tile
Layer 2: Gray grout and
mortar L2: ND N/A
10527-B-18 B9 Kitchen Black caulking on red ND N/A
quarry tile cove base
Layer 1: 1'x1' White ACT L1: ND N/A
w/ small hole pattern
10527-B-19 B11 Servery Layer 2: Dark brown glue L2: ND N/A
dot
Layer 3: GWB paper L3: ND N/A
Layer 1: 2'x4' SACT w/ L1: ND N/A
10527-B-20 B12 Fast Food paint
Layer 2: Plastic cover L2: ND N/A
Layer 1: Black window L1: ND N/A
10527-B-21 B9 Kitchen frame caulking
Layer 2: Off-white window L2: ND N/A
frame caulking
Layer 1: Gray caulking L1: ND N/A
10527-B-22 B9 Kitchen Layer 2: Silver caulking, L2: ND N/A
around sinks and wash
stations
Layer 1: 4" Cream colored L1: ND N/A
cove base
10527-B-23 B11 Servery Layer 2: Cream colored L2: ND N/A
mastic
Layer 3: JC w/ paint L3: ND N/A
Layer 4: GWB, at edge L4; ND N/A
10527-B- B5 Corridor Gray window frame 3% Chrysotile
24QAx caulking
Layer 1: 4"Tan/gray cove L1: ND N/A
base
Layer 2: Cream colored L2: ND N/A
10527-B-25 B5 Corridor mastic
Layer 3: Residual L3: 3% Chrysotile
brown mastic on
concrete
ehsi
30
EHS-International,Inc.
, 0 •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: White skim coat L1: ND N/A
10527-B-26 B1/B2 Cafeteria w/ paint
Layer 2: GWB (ceiling L2: ND N/A
edge)
Layer 1: White skim coat L1: ND N/A
10527-B-27 B1/B2 Cafeteria w/ paint
Layer 2: GWB (mid L2: ND N/A
ceiling)
Layer 1: White skim coat L1: ND N/A
10527-B-28 B1/B2 Cafeteria w/ paint
Layer 2: GWB (mid L2: ND N/A
ceiling)
10527-B-29 B2 Cafeteria Yellow/tan pipe dope ND N/A
10527-B-30 B2 Cafeteria White paint covering on ND N/A
2'x4' GWB SACT w/ paper
10527-B-31 B5 Corridor Remnant ACT w/ brown ND N/A
mastic on wood decking
Interior gray window
10527-B-32 B2 Cafeteria glazing putty 3% Chrysotile
(clearstory)
10527-B-33 B4A Riser Room Black pipe flange gasket ND N/A
BLOCK C
Layer 1: Gray window L1: ND N/A
Original Building frame caulking
10527-C-01 C-117 Layer 2: Black window L2: ND N/A
frame caulking w/ paint
and mastic
Original Building Layerframe 1:caulkin Blacgwindow L1: ND N/A
10527-C-02
C-117
w/paint
Layer 2: Wood debris L2: ND N/A
Layer 1: 4" Black cove L1: ND N/A
10527-C-03 Original Building base
C-117 Layer 2: Cream colored L2: ND N/A
mastic
10527-C-04 Original Building Black sink undercoat 3% Chrysotile
C-117
Layer 1: 12"x12" Off- L1: ND N/A
white VCT w/ brown,
10527-C-05 Original Building yellow and white streaks
C-117 Layer 2: Yellow mastic L2: ND N/A
Layer 3: Gray leveling L3: ND N/A
compound on concrete
ehsi�.� ;,
EHS-International,Inc.
• S ,
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Gray carpet L1: ND N/A
10527-C-06 Original Building backing w/ clear mastic
C-117 Layer 2: Gray leveling L2: ND N/A
compound on concrete
Original Building 2'x4' SACT w/ pin hole
10527-C-07 C-117 and worm track pattern ND N/A
w/paint
Layer 1: 1'x1' White SACT Li: ND N/A
Original Building w/ random pin hole
10527-C-08 C-117 pattern
Layer 2: Brown glue dot L2: ND N/A
w/ GWB paper
Original Building Layer 1: White texturing L1: ND N/A
10527-C-09 C-117 w/ paint
Layer 2: GWB (mid wall) L2: ND N/A
Original Building Layer 1: White texturing L1: ND N/A
10527-C-10 C-117 w/ paint
Layer 2: GWB (mid wall) L2: ND N/A
Original Building Layer 1: White texturing L1: ND N/A
10527-C-11 C-117 w/ paint
Layer 2: GWB (corner) L2: ND N/A
10527-COriginal Building Layer 1: 1'x1' ACT w/ L1: ND N/A
12QA Corridor C-116 large hole pattern
Layer 2: Brown glue dot L2: ND N/A
Original Building Layer 1: Skim coat Li: ND N/A
10527-C-13 w/paint
Corridor C-116
Layer 2: Plaster (ceiling) L2: ND N/A
Layer 1: Skim coat L1: ND N/A
10527-C-14 Original Building w/paint
Corridor C-116 Layer 2: Plaster (ceiling) L2: ND N/A
Layer 3: GWB L3: ND N/A
10527-C-15 Original Building Layer 1: Skim coat L1: ND N/A
Corridor C-116 Layer 2: Plaster (ceiling) L2: ND N/A
Layer 1: White coating on L1: ND N/A
10527-C-16 Original Building SACT w/paint
Corridor C-116 Layer 2: Silver foil L2: ND N/A
Layer 3: 2'x4' SACT L3: ND N/A
Layer 1: White skim coat L1: ND N/A
10527-C-17 Original Building w/ paint
Corridor C-116 Layer 2:GWB (mid ceiling) L2: ND N/A
Layer 1: White skim coat L1: ND N/A
10527-C-18 Original Building w/ paint
Corridor C-116 Layer 2:GWB (mid ceiling) L2: ND N/A
ehsi
EHS-International,Inc. 32
• w
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: White skim coat L1: ND N/A
10527-C-19 Original Building w/ paint
Corridor C-116 Layer 2:GWB, ceiling edge L2: ND N/A
Layer 1: 4"Tan/gray cove L1: ND N/A
base
10527-C-20 Original Building Layer 2: Cream colored L2: ND N/A
Corridor C-116 mastic
Layer 3: JC L3: ND N/A
Layer 4: GWB w/ paper L4: ND N/A
10527-C-21 Original Building Black window glazing ND N/A
Corridor C-116 putty w/mastic
Layer 1: 12"x12" Light L1: ND N/A
Gray VCT w/ gray and
Original Building white streaks
10527-C-22 Layer 2: Yellow mastic L2: ND N/A
Corridor C-116 Layer 3: Gray leveling L3: ND N/A
compound
Layer 4: Concrete debris L4: ND N/A
Layer 1: 12"x12" Blue L1: ND N/A
VCT
Original Building Layer 2: Yellow mastic L2: 3% Chrysotile
10527-C-23 Corridor C-116 on gray leveling
compound on residual
black mastic on
concrete
Layer 1: Yellow/tan L1: ND N/A
mastic (associated w/
12"x12" light gray VCT) L2: ND N/A
10527-C- Original Building Layer 2: Gray leveling
24QAx Corridor C-116 Compound L3: 9% Chrysotile
Layer 3: Black VAT L4: 3% Chrysotile
Layer 4: Black mastic
on concrete
Layer 1: Beige/Green L1: ND N/A
mastic
10527-C-25 Original Building Layer 2: Yellow mastic L2: ND N/A
Corridor C-116 Layer 3: Gray leveling L3: ND N/A
compound
Layer 4: Concrete debris L4: ND N/a
ehS/1.4 33
ENS-International,Inc.
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Yellow mastic L1: ND N/A
(associated w/ 12"x12"
off-white VCT (w/ brown,
Original Building yellow, and white
10527-C-26 Passage C-115 streaks)) L2: ND N/A
Layer 2: Gray leveling
compound 3% Chrysotile
Layer 3: Residual black
mastic on concrete
Layer 1: 1"x1" Light gray L1: ND N/A
ceramic floor tile
10527-C-27 Original Building Layer 2: Beige mastic L2: ND N/A
Women C-112 L3: ND N/A
Layer 3: Light gray grout L4: ND N/A
Layer 4: Dark gray mortar
Layer 1: 4"x4" White L1: ND N/A
Original Building ceramic wall tile
10527-C-28 Women C-112 Layer 2: Beige mastic L2: ND N/A
Layer 3: White grout L3: ND N/A
Layer 4: JC w/ paint L4: ND N/A
Layer 1: Beige/yellow L1: ND N/A
carpet mastic
Layer 2: 12"x12" Off- L2: ND N/A
10527-C-29 Original Building white VCT
Copy C-111 Layer 3: Gray leveling L3: 3% Chrysotile
compound on residual
black mastic on
concrete
Layer 1: Light Gray SVF L1: ND N/A
(w/ broken rock pattern) L2: ND N/A
Layer 2: Brown paper
10527-C-30 Original Building backing w/ mastic L3: ND N/A
Janitor C-110 Layer 3: Gray/Brown
leveling compound L4: 3% Chrysotile
Layer 4: Residual black
mastic on concrete
Original Building Layer 1: Silver duct paint L1: ND N/A
10527-C-31 C-107 Layer 2: Green/gray duct L2: ND N/A
seam sealant
Layer 1: White duct seam L1: ND N/A
10527-C-32 Original Building sealant
C-107 Layer 2: Green/gray duct L2: ND N/A
seam sealant
'' s •.
34
ENS-International,Inc.
•
Limited Hazardous Materials Survey Report
Federal Way High School
• EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Original Building
10527-C-33 Data Processing C- Black speaker coating ND N/A
109
Original Building Layer 1: 1'x1' ACT w/ L1: ND N/A
10527-C-34 Data Processing small pin hole pattern
C-109 Layer 2: Dark brown glue L2: ND N/A
dot
Layer 1: Blue carpet L1: ND N/A
Layer 2: Yellow/brown L2: ND N/A
Original Building mastic
10527-C-35 Career C-107 Layer 3: Gray leveling L3: ND N/A
compound
Layer 4: Residual black 3% Chrysotile
mastic on concrete
Layer 1: Yellow/tan carpet L1: ND N/A
mastic
Layer 2: Gray leveling L2: ND N/A
10527-C-36 Original Building compound
Office C-105 Layer 3: 9"x9" Black L3: 3% Chrysotile
VAT
Layer 4: Black mastic L4: 3% Chrysotile
on concrete
Original Building Layer 1: Skim coat w/ Li: ND N/A
10527-C-37 Career C-107
paint
Layer 2: Plaster (ceiling) Li: ND N/A
Original Building Layer 1: Skim coat w/ Li: ND N/A
10527-C-38 Career C-107 paint
Layer 2: Plaster (ceiling) L1: ND N/A
Original Building Layer 1: Skim coat w/ Li: ND N/A
10527-C-39 Career C-107 paint
Layer 2: Plaster (ceiling) Li: ND N/A
Original Building Layer 1: Yellow fiberglass L1: ND N/A
10527-C-40 Old Section of ceiling panels
Boiler Room Layer 2: Yellow/tan L2: ND N/A
mastic
Layer 1: Orange SVF (w/ L1: ND N/A
yellow and brown streaks)
Layer 2: Trace of yellow L2: ND N/A
10527-C- Original Building mastic
41QAX Girls C-135 Layer 3: Gray paper
L3: 2% Chrysotile
backing
Layer 4: Trace of black L4: 3% Chrysotile
mastic on concrete
ehsi
EHS-International,Inc. 35
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Original Building Tan pipe dope w/ fibrous
10527-C-42 Old Section of material and debris ND N/A
Boiler Room
Original Building Layer 1:1'x1' ACT w/ L1: ND N/A
10527-C-43 Girls C-135 metal decorative cover
Layer 2: Brown glue dot L2: ND N/A
Layer 1: Blue rubber stair L1: ND N/A
tread
10527-C-44 Original Building Layer 2: Brown mastic L2: ND N/A
Stair 4 Layer 3: Beige mastic L3: ND N/A
Layer 4: Brown wood L4: ND N/A
debris
Layer 1: 6" Blue rubber L1: ND N/A
10527-C-45 Original Building stringer
Stair 4 Layer 2: Yellow mastic L2: ND N/A
Layer 3: JC w/ paint L3: ND N/A
Original Building Layer 1: Skim coat w/ L1: ND N/A
10527-C-46 Career C-106
paint
Layer 2: Plaster (wall) L1: ND N/A
Original Building Layer 1: Skim coat w/ L1: ND N/A
10527-C-47 Career C-106
paint
Layer 2: Plaster (wall) L1: ND N/A
Original Building Layer 1: Skim coat w/ L1: ND N/A
10527-C-48 Career C-106
paint
Layer 2: Plaster (wall) L1: ND N/A
Layer 1: Skim coat w/ L1: ND N/A
10527-C-49 Original Building paint
Corridor C-116 Layer 2: GWB w/ paper L1: ND N/A
(corner)
Layer 1: Skim coat w/ L1: ND N/A
10527-C-50 Original Building paint
Corridor C-116 Layer 2: GWB w/ paper L1: ND N/A
(mid wall)
Original Building Layer 1: Skim coat w/ L1: ND N/A
10527-C-51 Men's Restroom C- paint
113 Layer 2: GWB w/ paper L1: ND N/A
(corner)
Original Building Layer 1: Skim coat w/ L1: ND N/A
10527-C-52 Men's Restroom C- paint
113 Layer 2: GWB w/ paper L1: ND N/A
(mid wall)
10527-C-53 Original Building Brown GWB w/ paint (mid ND N/A
Girls C-135 wall)
ehsi 4.0
36
EHS-International,Inc.
I •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Original Building Layer 1: White skim coat L1: ND N/A
10527-C-54 w/ paint
Office C-106
Layer 2: GWB (mid wall) L2: ND N/A
10527-C-55 Original Building GWB w/ paint and paper ND N/A
Conference C-108 (mid wall)
Original Building Layer 1: JC w/ paint L1: ND N/A
10527-C-56 Girls C-135 Layer 2: Brown GWB L2: ND N/A
(corner)
Original Building GWB w/ paint and paper
10527-C-57 Girls C-135 (mid wall) ND N/A
Original Building Layer 1: White skim coat Li: ND N/A
10527-C-58 Storage C-109/ w/ paint
I.H.S C102 Layer 2: GWB (mid wall) L2: ND N/A
Layer 1: Tan/brown L1: ND N/A
10527-C-59 Original Building caulking L2: ND N/A
Boiler, West Layer 2: Black flange
gaskets (on gas regulator)
10527-C-60 Original Building White coating w/ paint, on ND N/A
Boiler, West concrete wall
10527-C-61 Original Building Blue MAG TSI Fitting ND N/A
Boiler, West
10527-C-62 Original Building Blue MAG TSI Fitting ND N/A
Boiler, West
10527-C-63 Original Building Blue MAG TSI Fitting ND N/A
Boiler, West
Layer 1: White sealant L1: ND N/A
10527-C-64 Original Building w/paint
Boiler, West Layer 2: Yellow fiberglass L2: ND N/A
10527-C-65 Original Building White coating w/ paint on ND N/A
Boiler, West concrete walls
10527-C-66 Original Building White coating w/ paint on ND N/A
Boiler, West concrete walls
Original Building 2'x4' SACT w/ worm track
10527-C-67 2nd Floor E.S.L. C- and pin hole pattern ND N/A
208
Original Building Layer 1: 1'x1' ACT w/ pin L1: ND N/A
10527-C-68 2nd Floor E.S.L. C-
hole pattern
208 Layer 2: Brown glue dot L2: ND N/A
Layer 3: GWB w/ paper L3: ND N/A
Original Building Layer 1: White skim coat L1: ND N/A
10527-C-69 2nd Floor E.S.L. C- w/ paint
208 Layer 2: Plaster L2: ND N/A
Layer 3: GWB L3: ND N/A
ehsi..
EMS-International.Inc. 37
S !
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Original Building Layer 1: White skim coat
L1: ND N/A
10527-C-70 2nd Floor Corridor w/ paint
C-216 Layer 2: Plaster (on GWB) L2: ND N/A
Layer 1: White coating on Li: ND N/A
Original Building SACT w/paint
10527-C-71 2nd Floor Corridor Layer 2: Foil backing L2: ND N/A
C-216 Layer 3: 2'x4' SACT w/ L3: ND N/A
pin hole pattern
Original Building Layer 1: Hard L1: ND N/A
10527-C-72 2nd Floor Men's orange/brown flooring
Restroom C-220 Layer 2: Gray leveling L2: ND N/A
compound on concrete
Layer 1: Light gray SVF L1: ND N/A
(w/ broken rock pattern)
Original Building Layer 2: Beige paper L2: ND N/A
10527-C-73 2nd Floor backing w/ mastic
Janitors Closet Layer 3: 9"x9" Black L3: 3% Chrysotile
C-217 VAT
Layer 4: Black mastic L4: 3% Chrysotile
on wood
Layer 1: 12"x12" Off- L1: ND N/A
white/gray tile w/ yellow,
brown, and white streaks
Original Building Layer 2: Yellow mastic L2: ND N/A
10527-C-74 2nd Floor Storage 3: Gray leveling L3: ND N/A
Room C-218 compound Layer w/mastic
Layer 4: 9"x9" Black L4: 3% Chrysotile
VAT
Layer 5: Black mastic L5: 3% Chrysotile
on wood
Original Building Layer 1: White skim coat L1: ND N/A
10527-C-752nd Floor w/ paint
Layer 2: Plaster on GWB L2: ND N/A
Original Building Yellow carpet mastic on
10527-C-76 2nd Floor Dark wood ND N/A
Room C-219
Layer 1: Yellow carpet L1: ND N/A
Original Building mastic
10527-C- 2nd Floor Layer 2: 9"x9Dark red L2: 11% Chrysotile
VAT
77QAx Corridor C-216 Layer 3: Black mastic L3: 3% Chrysotile
Layer 4: Wood L4: ND N/A
38
EHS-International,Inc.
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Yellow carpet Li: ND N/A
Original Building mastic
10527-C-78 2"d Floor E. CR C- Layer 2: Gray leveling L2: ND N/A
202 compound w/ paint, at
door threshold on wood
Layer 1: Yellow/brown L1: ND N/A
carpet mastic
Layer 2: Residual black L2: 2% Chrysotile
Original Building mastic
10527-C-79 2nd Floor E. CR C- Layer 3: Brown fiber L3: ND N/A
206 board
Layer 4: Clear mastic L4: ND N/A
Layer 5: Hard wood floor L5: ND N/A
Layer 6: Black asphaltic L6: ND N/A
vapor barrier
Original Building Layer 1: 1'x1' ACT w/ L1: ND N/A
10527-C-80 2nd Floor Men's metal cover
Restroom C-220 Layer 2: Brown mastic L2: ND N/A
Original Building Layer 1: Skim coat w/ L1: ND N/A
10527-C-81 2nd Floor E. CR C- paint
201 Layer 2: Plaster walls L1: ND N/A
Original Building Layer 1: Skim coat w/ L1: ND N/A
10527-C-82 2nd Floor E. CR C- paint
201 Layer 2: Plaster walls L1: ND N/A
Original Building Layer 1: Skim coat w/ Li: ND N/A
10527-C-83 2nd Floor Corridor paint
C-216 Layer 2: Plaster walls L1: ND N/A
Original Building Layer 1: JC w/ paint Li: 0.25% Chrysotile
10527-C-84*2 2nd Floor Men's Layer 2: Brown GWB L2: ND N/A
Restroom C-220 (corner)
Original Building Brown GWB w/ paper
10527-C-85 2nd Floor Men's ND N/A
Restroom C-220 (mid wall)
Original Building Layer 1: Skim coat w/ L1: ND N/A
10527-C-86 2nd Floor Corridor paint
C-216 Layer 2: GWB w/ paper L2: ND N/A
(mid wall)
Original Building Layer 1: Skim coat w/ L1: ND N/A
10527-C-87 2nd Floor E. CR. C- paint
203 Layer 2: GWB w/ paint L2: ND N/A
and paper, (corner)
Original Building Layer 1: Skim coat w/ L1: 0.5% Chrysotile
10527-C-88*2 2nd Floor E. CR. C-
paint
203 Layer 2: GWB w/ paper L2: ND N/A
(mid wall)
ehsi
39
EHS-International,Inc.
• w
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: 4"Tan cove base L1: ND N/A
Original Building Layer 2: Cream colored L2: ND N/A
10527-C-89 2nd Floor E. CR. C- mastic
207 Layer 3: JC w/ paint and L3: ND N/A
paper
Original Building Black asphaltic vapor
2nd Floor Men's
10527-C-90 Restroom C 220, barrier(between wood ND N/A
pipe chase sub floor)
Original Building
10527-C-91 2nd Floor Men's Plaster wall ND N/A
Restroom C-220,
pipe chase
Original Building Layer 1: Yellow/tan L1: ND N/A
10527-C-92 2nd Floor E. CR. C- mastic
206 Layer 2: Tack board L1: ND N/A
10527-C-93 Original Building Light gray duct flange ND N/A
2nd Floor Attic sealant
10527-C-94 Original Building Green/gray duct seam ND N/A
2nd Floor Attic sealant
10527-C- Original Building NicoliteTM paper (in fire 56% Chrysotile
95QAx 2nd Floor Attic walls)
10527-C-96 Original Building Black asphaltic sealant 5% Chrysotile
2nd Floor Attic (at vent penetration)
Original Building Black asphaltic vapor
10527-C-972nd Floor Attic barrier (behind old wood ND N/A
siding)
Addition Section Tan paper backing w/
10527-C-98 Attic black mastic(under ND N/A
fiberglass batt insulation)
Original Building Layer 1: White TSI
L1: ND N/A
10527-C-99laggi
2nd Floor Room Laye g2: White MAG TSI L2: 55% Chrysotile
(Replacement of on small bore pipe run
Stairs) (abandoned in wall)
Building Addition 2'x4' SACT w/ pin hole
10527-C-100 2nd Floor E. CR. C- and worm track pattern ND N/A
212
Layer 1: 1'x1' ACT w/ L1: ND N/A
Building Addition pinhole pattern
10527-C-101 2nd Floor E. CR. C- Layer 2: Brown/black L2: ND N/A
212 mastic
Layer 3: GWB (ceiling) L3: ND N/A
SIa.
..
EHS-International,Inc. 40
I •
• Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Building Addition JC/GWB w/paint and
10527-C-102 2nd Floor E. CR. C- ND N/A
215 paper (ceiling, at seam)
Layer 1: Yellow carpet Li: ND N/A
Building mastic
10527-C- Addition 2nd Layer 2: 9"x9" Gray L2: 2% Chrysotile
103 Floor E. CR. C- VAT
212 Layer 3: Black mastic L3: 2% Chrysotile
Layer 4: Wood sub floor L4: ND N/A
Building Addition Layer 1:Yellow mastic w/ L1: ND N/A
10527-C-104 2nd Floor E. CR. C- residual black mastic
211 Layer 2: Wood sub-floor L2: ND N/A
Layer 1: 4" Gray cove L1: ND N/A
Building Addition base L2: ND N/A
10527-C-105 2nd Floor E. CR. C- Layer 2: Cream mastic L3: ND N/A
211 Layer 3: Residual brown
mastic w/ paint and paper
Building Addition
10527-C-106 2nd Floor E. CR. C- GWB (mid wall) ND N/A
213
Building Addition Layer 1: JC w/ paint L1: ND N/A
10527-C-107 2nd Floor Corridor Layer 2: GWB w/ paper L2: ND N/A
C-214 (seam)
10527-C- Building Addition Layer 1: JC w/ paint L1:0.75% Chrysotile
108*2 2nd Floor E. CR. C- Layer 2: GWB w/ paper L2: ND N/A
211 (corner)
Building Addition Layer 1: 4"Tan cove base L1: ND N/A
10527-C-109 2nd Floor E. CR. C- Layer 2: Brown mastic w/ L2: ND N/A
215 paper and paint
Building Addition Layer 1: JC w/ paint L1: ND N/A
10527-C-110 1st Floor Layer 2: GWB w/ paper L2: ND N/A
Conference C-118 (corner)
Building Addition GWB w/ paint andp ap er
10527-C-111 1st Floor Principal (mid wall) ND N/A
C-120
Building Addition Layer 1: JC w/ seam tape L1: ND N/A
10527-C-112 1st Floor Nurse and paint
Toilet C-127 Layer 2: GWB w/ paper L2: ND N/A
(seam)
Building Addition Layer 1: JC w/ paint L1: ND N/A
10527-C-113 1st Floor Nurse Layer 2: Skim coat L2: ND N/A
Toilet C-127 Layer 3: GWB w/ paper L3: ND N/A
(mid wall)
s e)
EHS-International,Inc. 41
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527 •
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Building Addition Layer 1: 1'x1' ACT w/ pin L1: ND N/A
10527-C-114 1st Floor Nurse hole pattern
Toilet C-128 Layer 2: Brown glue dot L2: ND N/A
Layer 3: GWB w/ paper L3: ND N/A
10527-C-115 Building Addition 2'x4' SACT w/ worm track ND N/A
1st Floor VP C-124 and pin hole pattern
Layer 1: Gray SVF Li: ND N/A
Building Addition Layer 2: Beige paper L2: ND N/A
10527-C-116 1st Floor Nurse backing w/ mastic
Toilet C-127 Layer 3: Gray leveling L3: ND N/A
compound on residual
black mastic on concrete
Layer 1: 12"x12" Off- L1: ND N/A
white/gray VCT (w/
10527-C- Building brown, yellow and white
117QAX Addition 1st Floor streaks)
Nurse C-126 Layer 2: Yellow mastic L2: ND N/A
Layer 3: Residual black L3: 3% Chrysotile
mastic on concrete
Building Addition Layer 1: Skim coat w/ L1: ND N/A
10527-C-118 1St Floor Nurse paint
Toilet C-127 Layer 2: GWB w/ paper L2: ND N/A
(mid wall)
Building Addition Layer 1: JC w/ paint L1: ND N/A
10527-C-119 1st Floor Clerical C- Layer 2: GWB w/ paper L2: ND N/A
122 Corridor (corner)
Building Addition Layer 1: JC w/ paint L1: ND N/A
10527-C-120 1st Floor BKPR C- Layer 2: GWB w/ paper L2: ND N/A
131 (mid wall)
Building Addition Layer 1: White 1'x1' ACT L1: ND N/A
10527-C-121 1st Floor V.P. C- paint
1
123 Layer 2: 'x1' ACT L2: ND N/A
Layer 3: Brown glue dot L3: ND N/A
Layer 1: Yellow carpet L1: ND N/A
mastic
Building
10527-C- Addition 1st Floor Layer 2: 9 x9„ Off- L2: 2% Chrysotile
122 white VAT
V.P. C-125 Layer 3: Black mastic o
on concrete L1: 3 /o Chrysotile
Building Addition Layer 1: Yellow carpet L1: ND N/A
10527-C-123 1st Floor V.P. C- mastic
124 Layer 2: Gray leveling L2: ND N/A
compound on concrete
ehsi akit
42
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Yellow carpet L1: ND N/A
Building mastic rr
10527-C- Addition 15t Floor Layer 2: 9"x9" Gray L2: 3%
N/A
124 VAT
V.P. C-123 Layer 3: Black mastic L3: 3% N/A
on concrete
Layer 1: Yellow carpet L1: ND N/A
Building mastic
10527-C- Addition 1st FloorLayer 2: Gray leveling L2: ND N/A
125QAx Principal compound
Corridor Layer 3: Residual black L3: 3% Chrysotile
mastic on concrete
Building Addition
10527-C-126 1st Floor Office C- White sink undercoat ND N/A
128
Building Addition Layer 1: Yellow carpet L1: ND N/A
10527-C-127 1st Floor Work C- mastic
130 Layer 2: Off-white VCT L2: ND N/A
Layer 3: Yellow mastic L3: ND N/A
BLOCK D
Layer 1: 4"Tan cove base L1: ND N/A
Layer 2: Tan mastic
10527-D-01 Library D-15 Layer 3: Residual brown L2: ND N/A
mastic L3: ND N/A
Layer 1: Blue carpet L1: ND N/A
Layer 2: Yellow/tan L2: ND N/A
10527-D-02 Library D-15 mastic
Layer 3: Residual black L3: 3% Chrysotile
mastic on concrete
Layer 1: 1'x1' White ACT L1: ND N/A
(with random pinhole
Library D-15, pattern) L2: ND N/A
10527-D-03 Reception Area Layer 2: Dark brown glue
dot
Layer 3: Unfinished GWB L3: ND N/A
(pinkish color)
White NicoliteTM paper
10527-D-04 Library Attic (in fire wall) 65% Chrysotile
Layer 1: Silver coat/paint L1:ND N/A
10527-D-05 Library Attic Layer 2: Black asphaltic L2: 5% Chrysotile
tar/sealant
ehsi
EHS-International,Inc. 43
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Blue carpet L1: ND N/A
Layer 2: Yellow/tan L2: ND N/A
10527-D-06 Library D15 mastic
Layer 3: Residual black L3: 3% Chrysotile
mastic on concrete
Layer 1: Gray carpet foam L1: ND N/A
backing
Layer 2: Clear mastic L2: ND N/A
Layer 3: 12"x 12" Off- L3: ND N/A
10527-D-07 MAG D-20 white VCT (with brown,
yellow, and white streaks)
Layer 4: Yellow mastic L4: ND
Layer 5: Residual black 15: 3% N/A
mastic on concrete Chrysotile
Layer 1: Blue carpet L1: ND N/A
Layer 2: Yellow/tan L2: ND N/A
mastic
10527-D-08 Library D-15 Layer 3: Residual black L3: 3% Chrysotile
mastic
Layer 4: White material L4: ND N/A
on concrete
10527-D-09 Library Attic Green/gray duct seam ND N/A
sealant
10527-D-10 South Storage White sink undercoat ND N/A
Room
2'x4' SACT (with worm
10527-D-11 A.V.CR. D-17 track and pin hole ND N/A
pattern)
Layer 1: 1'x1' White ACT L1: ND N/A
(with random pin hole
10527-D-12 A.V.CR. D-17 Pattern)
Layer 2: Dark brown glue L2: ND N/A
dot
Layer 3: Unfinished GWB L3: ND N/A
Layer 1: Carpet L1: ND N/A
Layer 2: Brown mastic L2: ND N/A
Layer 3: Orange mastic L3: ND N/A
10527-D- Corridor D-14 Layer 4: 9"x 9" Tan L4: 2% Chrysotile
13QAx VAT (with white and
brown streaks)
Layer 5: Black mastic L5: 4% Chrysotile
on concrete
ehsi..
EHS-International,Inc. 44
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: 4" Gray cove L1: ND N/A
base w/paint
10527-D-14 Corridor D-14 Layer 2: Cream mastic L2: ND N/A
Layer 3: Residual brown L3: ND N/A
mastic
Layer 1: 4" Black cove L1: ND N/A
10527-D-15 MAG D-20 base
Layer 2: Cream mastic w/ L2: ND N/A
GWB paper and paint
10527-D-16 South Storage GWB with paint (mid wall) ND N/A
Room
South Storage Layer 1: JC (patch) L1: ND N/A
10527-D-17 Room Layer 2: GWB w/ paint L2: ND N/A
and paper (mid ceiling)
South Storage Layer 1: JC w/ paint L1: ND N/A
10527-D-18 Room Layer 2: GWB w/ paper L2: ND N/A
(ceiling edge)
Layer 1: JC w/ paint L1: 0.5% Chrysotile
10527-D-19*3 A.V. CR. D-17 Layer 2: GWB w/ paper L2: ND N/A
(mid wall)
10527-D-20 Library D-15 GWB w/ paint and paper ND N/A
(mid wall)
Layer 1: White skim coat L1: ND N/A
10527-D-21 Library D-15 w/ paint
Layer 2: Plaster column L2: ND N/A
Layer 1: White skim coat L1: 0.25% Chrysotile
10527-D-22*3 Library D-15 w/ paint
Layer 2: Plaster column L2: ND N/A
10527-D-23 Library D-15 Plaster w/ paint on ND N/A
column
Layer 1: JC w/ paint L1: ND N/A
10527 D 24*3 MAG D-20 Layer 2: JC w/ paint L2: 0.5% Chrysotile
Layer 3: GWB w/ paper L3: ND N/A
(corner wall)
Layer 1: JC w/ paint L1: 0.5% Chrysotile
10527-D-25*3 Library D-15 Layer 2: GWB w/ paper L2: ND N/A
(mid wall)
10527-D-26 South Storage GWB w/ paint and paper ND N/A
Room (corner wall)
Layer 1: 2" Beige ceramic L1: ND N/A
wall tile
10527-D-27*3 Library D-15 Layer 2: White grout L2: ND N/A
Layer 3: Yellow mastic L3: ND N/A
Layer 4: GWB L4: 0.75% Chrysotile
ehs14
EHS-International,Inc. 45
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: 1'x1' White ACT L1: ND N/A
(w/ worm track and pin
10527-D-28 Corridor D-14 hole pattern)
Layer 2: Brown glue dot L2: ND N/A
Layer 3: JC L3: ND N/A
Layer 4: GWB (seam) L4: ND N/A
Layer 1: JC w/ paint L1: 0.5% Chrysotile
Layer 2: Wall joint tape L2: ND N/A
10527-D-29*3 Building Addition Layer 3: Old JC on L3: 0.5% Chrysotile
SS. CR. D-5 partition wall w/ paper
Layer 4: Old GWB L4: ND N/A
partition wall w/ paper
Layer 1: 1'x1' White ACT L1: ND N/A
10527-D-30 Building Addition (w/ worm track and pin
Corridor D-13 hole pattern)
Layer 2: Brown glue dot L2: ND N/A
Layer 1: 4"Tan cove base L1: ND N/A
10527-D- Building Addition Layer 2: Cream mastic
31QA SS. CR. D-5 Layer 3: Residual brown L2: ND N/A
mastic L3: ND N/A
Layer 1: Blue carpet L1: ND N/A
10527-D-32 Building Addition Layer 2: Yellow mastic L2: ND N/A
SS. CR. D-5 Layer 3: Residual dark L3: ND N/A
gray mastic on concrete
Layer 1: Yellow carpet L1: ND N/A
Building Addition mastic
10527-D-33 SS. CR. D-7 Layer 2: White leveling L2: ND N/A
compound
Layer 3: Concrete L3: ND N/A
Layer 1: Yellow carpet L1: ND N/A
mastic
10527-D-34 Building Addition Layer 2: Dark gray mastic L2: ND N/A
SS. CR. D-6 Layer 3: Light gray
leveling compound on L3: ND N/A
concrete
Layer 1: 4" Light gray L1: ND N/A
10527-D-35 Building Addition cove base
SS. CR. D-8 Layer 2: White mastic L2: ND N/A
Layer 3: JC w/ paint L3: ND N/A
Layer 1: Gray foam carpet L1: ND N/A
Building backing
10527-D-36 Addition Layer 2: Clear/yellow L2: ND N/A
Corridor D-13 mastic
Layer 3: Residual black L3: 3% Chrysotile
mastic on concrete
'"" s `e 46
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Building Addition Layer 1: Black foam L1: ND N/A
10527-D-37 carpet backing
Conference D-12
Layer 2: Beige mastic L2: ND N/A
Building Addition GWB w/ paint and paper
10527-D-38 Corridor D-13 (mid wall) ND N/A
10527-D-39 Building Addition GWB w/ paint and paper ND N/A
S.S. CR. D-1 (mid wall)
10527-D-40 Building Addition Layer 1: JC w/ paint L1: ND N/A
D-4 Layer 2: GWB w/ paper L2: ND N/A
Layer 1: JC w/ paint L1: ND N/A
310527-D-41Building Addition Layer 2: JC w/ paint L2: 0.5% Chrysotile
D-4 Layer 3: GWB w/ paper L3: ND N/A
(corner wall)
Building Addition Layer 1: JC w/ paint L1: ND N/A
10527-D-42D 7 Layer 2: GWB w/ paper L2: ND N/A
(corner wall)
10527-D- Building
43QAx Addition Office Black sink undercoat 5% Chrysotile
D-11
10527-D-44 Building Addition Black foam window ND N/A
SS. CR. D-7 glazing w/ clear mastic
Layer 1: Gray door frame L1: ND N/A
10527-D-45 Building Addition caulking on double door
Layer 2: Brick debris L2: ND N/A
Layer 3: Gray mortar L3: ND N/A
BLOCK E
L1: ND N/A
Layer 1: Blue carpet L2: ND N/A
10527-E-01 Classroom E-17 Layer 2: Yellow mastic L3: Not
Layer 3: White leveling mentioned
by the Lab
Layer 1: 4"Tan cove base L1: ND N/A
10527-E-02 Classroom E-17 Layer 2: Cream mastic
L2: ND N/A
Layer 1: White paint L1: ND N/A
Layer 2: Silver foil L2: ND N/A
10527-E-03 Corridor E-22 Layer 3: White mastic L3: ND N/A
Layer 4: 2'x4' White L4: ND N/A
SACTw/ pin hole pattern
ehsi
EHS-International,Inc. 47
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: 12"x12" Off- L1: ND N/A
white VCT
Layer 2: Yellow mastic L2: ND N/A
10527-E-04 Janitor E-15 Layer 3: Black mastic L3: ND N/A
Layer 4: Gray leveling L4: ND N/A
compound on concrete
floor
Layer 1:12"x 12" Off- L1: ND N/A
Drama Storage E- white VCT
10527-E-0519 Layer 2: Yellow mastic L2: ND N/A
Layer 3: Residual black L3: ND N/A
mastic on concrete
Layer 1: 12"x 12" Light L1: ND N/A
gray VCT (w/ gray and
white streaks)
10527-E-06 Corridor E-8 Layer 2: Off-white/yellow L2: ND N/A
mastic
Layer 3: Residual black L3: 3% N/A
mastic
Layer 4: Concrete debris L4: ND N/A
Layer 1: 12"x 12" Blue L1: ND N/A
VCT
10527-E-07 Corridor E-8 Layer 2: Yellow mastic L2: ND N/A
Layer 3: Residual black L3: 3% Chrysotile
mastic on concrete
10527-E-08
Drama Storage E Tan pipe dope ND N/A
Layer 1: Yellow carpet L1: ND N/A
10527-E-09 Vestibule E-25 mastic
Layer 2: Residual black L2: 3% Chrysotile
mastic
Drama Storage E-
Layer 1: White plaster L1: ND N/A
10527-E-10 19 Layer 2: GWB w/ paper L2: ND N/A
on ceiling
Drama Storage E-
Layer 1: White plaster L1: ND N/A
10527-E-11 19 Layer 2: GWB w/ paper L2: ND N/A
on ceiling
Drama Storage E-
Layer 1: White plaster L1: ND N/A
10527-E-12 19 Layer 2: GWB with paper L2: ND N/A
on ceiling
ehcry
s1 . 48
ENS-international,Inc,
•
Limited Hazardous Materials Survey Report
Federal Way High School
• EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Yellow carpet ND ND
mastic
Layer 2: Thin white L2: ND ND
powdery material
10527-E- S.S.C.R E-21 Layer 3: Gray brittle ND ND
13QA material
Layer 4: 9"x9" Light 3% Chrysotile
blue VAT
Layer 5: Black mastic L3: 5% Chrysotile
on concrete
Layer 1: 1'x 1' White ACT L1: ND N/A
(with pin hole and worm
10527-E-14 Foyer E-18 track pattern)
Layer 2: Brown glue dot L2: ND N/A
Layer 3: GWB paper L3: ND N/A
Layer 1: 9"x 9" Light L1: 3% Chrysotile
10527-E-15 Theater E-10 brown VAT
Layer 2: Black mastic L2: 3% Chrysotile
on concrete
10527-E-16 S.S.C.R E-21 2'x4' SACT (with worm ND N/A
track and pinhole pattern)
Layer 1: 2" Gray ceramic L1: ND N/A
floor tile
10527-E-17 Men's Restroom Layer 2: Dark gray grout L2: ND N/A
E-5 Layer 3: Cream mastic L3: ND N/A
Layer 4: Gray leveling L4: ND N/A
compound on concrete
Layer 1: 4" White ceramic L1: ND N/A
wa II
10527-E-18 E 5's Restroom La
10527-E-18 Light brown L2: ND N/A
grout
Layer 3: White mastic L3: ND N/A
Layer 1: Newer white sink Li: ND N/A
10527-E-19 Men's Restroom caulking
E-5 Layer 2: Older white sink L2: ND N/A
caulking
Layer 1: 1'xl' ACT (with Li: ND N/A
10527-E-20 Greenroom E-7 fissure pattern)
Layer 2: Brown glue dot L2: ND N/A
10527-E-21 Greenroom E-7 Gray duct seam sealant ND N/A
Layer 1: 4" Black cove L1: ND N/A
base
10527-E-22 Theater E-10 Layer 2: Brown mastic L2: ND N/A
Layer 3: Residual dark L3: ND N/A
brown mastic
ehsi
EHS-International.Inc. 49
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527 `
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
10527-E-23 Drama Cr. E-1 Residual brown cove base ND N/A
on casework
Layer 1: Black foam L1: ND N/A
window glazing
10527-E-24 Drama Cr. E-1 Layer 2: Clear mastic L2: ND N/A
Layer 3: Gray window L3: ND N/A
glazing
10527-E-25 Greenroom E-7 White sink undercoat ND N/A
Layer 1: Yellow/orange L1: ND N/A
carpet mastic
10527-E- Greenroom E-7 Layer 2: 9"x 9" Tan L2: 4% Chrysotile
26QAX VAT
Layer 3: Black mastic L3: 3% Chrysotile
on concrete
10527E Dressing Room E-
Layer 1: White skim coat L1: ND N/A
27QA 5 Layer 2: Old gray plaster L2: ND N/A
Layer 3: GWB with paper L3: ND N/A
Dressing Room E-
Layer 1: White skim coat L1: ND N/A
10527-E-286 Layer 2: Old gray plaster L2: ND N/A
Layer 3: GWB with paper L3: ND N/A
Dressing Room E-
Layer 1: White skim coat L1: ND N/A
10527-E-296 Layer 2: Old gray plaster L2: ND N/A
Layer 3: GWB with paper L3: ND N/A
Layer 1: Silver foil Li: ND N/A
Dressing Room E-
Layer 2: Paper backing w/ L2: ND N/A
10527-E-305 black mastic
Layer 3: Black fiberglass L3: ND N/A
batting insulation
Layer 1: White skim coat L1: ND N/A
10527-E-31 Men Restroom E-3 w/ paint
Layer 2: Gay plaster on L2: ND N/A
ceiling
Layer 1: White skim coat L1: ND N/A
10527-E-32 Men Restroom E-3 w/ paint
Layer 2: Gay plaster on L2: ND N/A
ceiling
Layer 1: White skim coat L1: ND N/A
10527-E-33 Men Restroom E-3 w/ paint
Layer 2: Gay plaster on L2: ND N/A
ceiling
Layer 1: 1'x i' ACT (w/ L1: ND N/A
10527-E-34 Stage E-9 large pin hole pattern)
Layer 2: Brown glue dot L2: ND N/A
on plaster ceiling
10527-E-35 Stage E-9 Plaster on GWB ceiling ND N/A
' i/
50
EHS-International,Inc.
e 0
Limited Hazardous Materials Survey Report
Federal Way High School
:' EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: White skim coat L1: ND N/A
10527-E-36 Stage E-9 w/ paint
Layer 2: Gay plaster on L2: ND N/A
ceiling
Layer 1: White skim coat L1: ND N/A
10527-E-37 Stage E 9 w/ Paint
Layer 2: Gay plaster on L2: ND N/A
ceiling
Layer 1: White skim coat L1: ND N/A
10527E Theater E-10 w/ Paint
38QA Layer 2: Gay plaster on L2: ND N/A
ceiling
Layer 1: White skim coat L1: ND N/A
10527-E-39 Theater E-10 w/ Paint
Layer 2: Gay plaster on L2: ND N/A
ceiling
Layer 1: JC w/ paint and L1: ND N/A
10527-E-40 Classroom E-17 Paper
Layer 2: GWB with paper, L2: ND N/A
mid wall
Layer 1: JC w/ paint and L1: ND N/A
10527-E-41 FoyerE-18 paper
Layer 2: GWB w/ paper L2: ND N/A
(mid wall)
Layer 1: JC w/ paint and L1: ND N/A
10527-E-42 Corridor E-8 paper
Layer 2: GWB w/ paper L2: ND N/A
(mid wall)
Layer 1: JC w/ paint L1: ND N/A
10527-E-43 Foyer E-18 Layer 2: GWB w/ paper
(corner wall) L2: ND N/A
Layer 1: JC w/ paint and L1: ND N/A
10527-E-44 S.S.C.R E-21 paper
Layer 2: GWB w/ paper L2: ND N/A
(corner wall)
Layer 1: Blue/green L1: ND N/A
carpet
Layer 2: Gray foam L2: ND N/A
10527-E-45 Block E Addition, backing
Room 3 Layer 3: Yellow/clear L3: ND N/A
mastic
Layer 4: Gray leveling L4: ND N/A
compound on concrete
ehsi.. s>
EHS-International,Inc.
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527 •
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: White door frame L1: ND N/A
10527-E-46 Corridor E-8 caulking
Layer 2: Beige door frame L2: ND N/A
caulking w/paint
Layer 1: Gray window L1: ND N/A
10527-E-47 Block E Addition, frame caulking
Room 3 Layer 2: Black foam L2: ND N/A
insulation
Block E Addition Layer 1: JC L1: ND N/A
10527-E-48 Layer 2: GWB w/ paper, L2: ND N/A
Corridor corner wall
10527-E-49 Block E Addition GWB w/ paper (mid wall) ND N/A
Corridor
10527E 50 Block E Addition, GWB w/ paint and paper ND N/A
Room 4 (mid wall)
10527-E-51 Block E Addition, Gray duct seam sealant ND N/A
Room 2
Block E Addition Layer 1: JC L1: ND N/A
10527-E-52 Corridor Layer 2: GWB w/ paper L2: ND N/A
(ceiling seam)
Block E Addition, Layer 1: 4"Tan cove base
L1: ND N/A
10527-E-53 Room 5 Layer 2: Cream mastic L2: ND N/A
Layer 3: JC w/ paint L3: ND N/A
10527E 54 Block E Addition, Blue paint on new plaster ND N/A
Room 3 ceiling
10527E 55 Block E Addition, Blue paint on new plaster ND N/A
Room 3 ceiling
10527E 56 Block E Addition, Blue paint on new plaster ND N/A
Room 4 ceiling
BLOCK F
L1: ND N/A
Layer 1: 12"x12" Off-
White VCT (w/ brown,
10527-F-01 Sewing F-8 yellow, and white streaks)
Layer 2: Yellow mastic L2: ND N/A
Layer 3: Residual black L3: 3% Chrysotile
mastic on concrete
Layer 1: 12"x12" Blue L1: ND N/A
VCT w/ shades of blue
10527-F-02 Cooking F-4 Layer 2: Yellow mastic L2: ND N/A
Layer 3: White leveling L3: ND N/A
compound
Layer 4: Concrete debris L4: ND N/A
e SIS..
52
EHS-International,Inc.
s �r
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: 9"x9" Tan VAT L1: 3% Chrysotile
(w/ brown and yellow
10527-F-03 Electrical F-1 streaks)
Layer 2: Black mastic L2: 3% Chrysotile
on concrete
Layer 1: 9"x9" Light L1: 3% Chrysotile
Brown VAT (w/
10527-F-04 Electrical F-1 rainbow streaks)
Layer 2: Black mastic L2: 3% Chrysotile
on concrete
10527-F-05 West Mechanical Gray pipe dope on gas ND N/A
Room line fittings
10527-F-06 West Mechanical Yellow pipe dope on gas ND N/A
Room line fittings
Layer 1: White skim coat Li: ND N/A
10527-F- West Mechanical w/ paint
07QA Room Layer 2:Plaster wall L2: ND N/A
Layer 3: GWB L3: ND N/A
10527-F-08 Cooking F-4 Gray sink undercoat ND N/A
10527-F-09 Cooking F-4 White sink undercoat ND N/A
East Mechanical Layer 1: White paint on Li: ND N/A
10527-F-10 Room (Storage 1x1 ACT
Room) Layer 2: 1x1' ACT L2: ND N/A
Layer 3: Brown glue dot L3: ND N/A
Layer 1: White paint on L1: ND N/A
1'x l' ACT
10527-F-11 Corridor F-10 Layer 2: 1'x1' Gray ACT L2: ND N/A
Layer 3: Brown glue dot L3: ND N/A
Layer 4: GWB (ceiling) L4: ND N/A
Layer 1: 9"x9" Olive L1:2% N/A
10527-F-12 Biology CR green VAT
Layer 2: Black mastic L2: 3% N/A
on concrete
10527-F-13 Biology CR Pink sink undercoat ND N/A
10527-F-14 Biology CR Black counter top ND N/A
Layer 1: 4" Black cove L1: ND N/A
10527-F-15 Biology CR base
Layer 2: Brown mastic on L2: ND N/A
casework
10527-F-16 Biology CR White sink undercoat on ND N/A
ceramic sinks
Layer 1: 9"x9" L1: 3% Chrysotile
10527-F-17 Storage F-17 Brown/red VAT
Layer 2: Black mastic L2: 3% Chrysotile
on concrete
ehsi.)
EHS-International,Inc. 53
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: (Carpet on) L1: 2% Chrysotile
12'x12" Beige VAT (w/
10527-F-18 Electronics F-19 brown streaks)
Layer 2: Black mastic L2: 3% Chrysotile
on concrete
Layer 1: Off-white SVF w/ L1: ND N/A
rock pattern
10527-F-19 Toilet F-12 Layer 2: Gray paper L2: ND N/A
backing w/ yellow mastic
on concrete
Layer 1: Yellow carpet L1: ND N/A
mastic L2: 3% Chrysotile
10527-F-20 Special Ed F-13 Layer 2: 9"x9Red VAT
Layer 3: Black mastic L3: 3% Chrysotile
on concrete
Layer 1: Green/Gray L1: ND N/A
carpet mastic
Layer 2: Yellow carpet L2: ND N/A
mastic
10527-F-21 Special Ed. F-15 Layer 3: 9"x9" Light L3: 3% Chrysotile
brown VAT (w/
rainbow streaks)
Layer 4: Black mastic L4: 3% Chrysotile
on concrete
10527-F-22 Drafting F-16 Black sink undercoat 2% Chrysotile
10527-F-23 Drafting F-16 GWB (mid wall) ND N/A
Child Development Layer 1: JC w/ paint L1: ND N/A
10527-F-24 F-11 Layer 2: GWB w/ paper L2: ND N/A
(corner)
Layer 1:White skim coat L1: ND N/A
10527-F-25 Corridor F-15 w/ paint
Layer 2: Plaster wall L2: ND N/A
Layer 1: 1'x1' ACT L1: ND N/A
10527-F-26 Drafting F-16 Layer 2: Brown glue dot L2: ND N/A
Layer 3: Texturing L3: ND N/A
overspray
Layer 1: 1'x1' ACT L1: ND N/A
10527-F- Layer 2: Brown glue dot L2: ND N/A
Drafting F-16
27QA Layer 3: Texturing L3: ND N/A
overspray
Layer 1: Trace of L1: ND N/A
10527-F-28 Cooking F-4 texturing overspray
Layer 2: GWB paper L2: ND N/A
Layer 3: GWB L3: ND N/A
ehsi. 54
EHS-International,Inc.
111 •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Yellow mastic L1: ND N/A
(beneath 12"x12" light
gray VCT)
10527-F-29 Corridor F-15 Layer 2: Gray leveling L2: ND N/A
compound
Layer 3: Residual Black L3: ND N/A
mastic
BLOCK G
Layer 1: 12"x12" Light L1: ND N/A
gray VCT (with white and
gray streaks)
Corridor G-13, Layer 2: Tan mastic L2: ND N/A
10527-G-01 Outside Boys Layer 3: White leveling L3: ND N/A
Restroom G-12 compound
Layer 4: Gray VAT L4: 2% Chrysotile
Layer 5: Black mastic L5: 3% Chrysotile
on wood
Layer 1: 12"x12" Blue L1: ND N/A
VCT
Corridor G-13, Layer 2: Tan mastic L2: ND N/A
10527-G-02 Outside Boys Layer 3: White leveling L3: ND N/A
Restroom g-12 compound o
Layer 4: Gray VAT L4: 2% Chrysotile
Layer 5: Black mastic L5: 3% Chrysotile
on wood
Layer 1: 12"x12" gray L1: ND N/A
VCT (with maroon
streaks)
Layer 2: Tan mastic L2: ND N/A
10527-G-03 Storage G10A Layer 3: White leveling L3: ND N/A
compound
Layer 4: Gray VAT L4: 2% Chrysotile
Layer 5: Black mastic 15: 3% Chrysotile
on wood
Layer 1: 2" Red/tan L1: ND N/A
ceramic floor tile
10527-G-04 Boys Restroom G- Layer 2: Dark gray grout L2: ND N/A
12 Layer 3: Light gray mortar L3: ND N/A
Layer 4: Trace yellow
mastic L4: ND N/A
Layer 1: 4" White ceramic L1: ND N/A
10527-G-05 Boys Restroom g- cove base
12 Layer 2: Dark gray grout L2: ND N/A
Layer 3: Light gray mortar L3: ND N/A
ehsi
EHS-International.Inc. 55
• S
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Blue/gray carpet L1:ND N/A
Micro Computer Layer 2: Tan mastic L2: ND N/A
10527-G-06G-7 Layer 3: Tan VAT L3: 2% Chrysotile
Layer 4: Black mastic L4: 3% Chrysotile
on wood
Layer 1: Blue gray carpet L1: ND N/A
Layer 2: Tan mastic
10527-G-07 Bus Office G-10 Layer 3: Gray VAT L2: ND N/A
Layer 4: Black mastic L3: 2% Chrysotile
on wood L4: 3% Chrysotile
10527-G-08 Bus Office G-10 2'x4' SACT (with pin hole ND N/A
and worm track pattern)
Layer 1: 1'x 1' ACT (with L1: ND N/A
10527-G-09 Bus Office G-10 pin hole pattern)
Layer 2: Brown glue dot L2: ND N/A
w/ paint
Layer 1: Gray paint L1: ND N/A
10527-G-10 Storage G l0A Layer 2: White skim coat L2: ND N/A
Layer 3: GWB with paper L3: ND N/A
(mid ceiling)
Layer 1: Gray paint L1: ND N/A
10527-G-11 Janitor Closet G-9 Layer 2: White skim coat L2: ND N/A
Layer 3: GWB with paper L3: ND N/A
(mid ceiling)
10527-G-12 Computer E-5 ACT)GWB (beneath 1'x1' ND N/A
10527-G-13 Micro Computer G- Bare GWB (beneath 1'x1' ND N/A
7 ACT)
Micro Computer G-
Layer 1: Residual ACT L1: ND N/A
10527-G-147 Layer 2: Brown glue dot L2: ND N/A
w/paint, on wall
Layer 1: Multi-colored L1: ND N/A
Micro Computer G-
paint
10527-G-157 Layer 2: White skim coat L2: ND N/A
Layer 3: Gray plaster L3: ND N/A
beneath GWB wall
Layer 1: Gray paint L1: ND N/A
10527-G-16 Girls Restroom E-5 Layer 2: White skim coat L2: ND N/A
Layer 3: GWB with paper L3: ND N/A
(mid ceiling)
Layer 1: Tan paint L1: ND N/A
10527-G-17 Boys Restroom G- Layer 2: White skim coat L2: ND N/A
12 Layer 3: Gray plaster on L3: ND N/A
ceiling
ehaSim
EHS-International,Inc. 56
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Tan paint L1: ND N/A
10527-G-18 Boys Restroom G- Layer 2: White skim coat L2: ND N/A
12 Layer 3: Gray plaster on L3: ND N/A
ceiling
Layer 1: Tan paint L1: ND N/A
10527-G-19 Bus Office G-10 Layer 2: White skim coat L2: ND N/A
Layer 3: Gray plaster on L3: ND N/A
ceiling
Layer 1: Brown glue dot L1: ND N/A
10527-G-20 Boys Restroom G- Layer 2: Tan/gray paint L2: ND N/A
12 Layer 3: Gray plaster on L3: ND N/A
ceiling
Layer 1: Tan paint L1: ND N/A
10527-G- Layer 2: White skim coat L2: ND N/A
21QA Bus Office G-10 Layer 3: Gray plaster on L3: ND N/A
ceiling
10527-G-22
Boys Restroom G Tan pipe dope w/debris ND N/A
Layer 1: Multi-colored L1: ND N/A
paint
10527-G-23 Bus C.R G-4 Layer 2: White skim coat L2: ND N/A
Layer 3: Gray plaster, mid L3: ND N/A
wall (beneath GWB)
L1: ND N/A
Layer 1: 4"Tan cove base
10527-G-24 Corridor G-13 Layer 2: Off-white mastic L2: ND N/A
Layer 3: Trace JC
L3: ND N/A
Layer 1: Beige paint L1: ND N/A
Layer 2: White skim coat L2: ND N/A
10527-G-25 Simulators G-1 with yellow wall seam tap
Layer 3: GWB with paper
(corner wall) L3: ND N/A
Layer 1: Beige paint L1: ND N/A
10527-G-26 Computer G-5 Layer 2: White skim coat L2: ND N/A
Layer 3: GWB with paper L3: ND N/A
(mid wall)
Layer 1: Beige paint L1: ND N/A
10527-G-27 Micro Computer G- Layer 2: White skim coat L2: ND N/A
7 Layer 3: GWB with paper L3: ND N/A
(corner wall)
Layer 1: Blue paint L1: ND N/A
10527-G-28 Corridor G-13 Layer 2: White skim coat L2: ND N/A
Layer 3: GWB with paper L3: ND N/A
(mid wall)
ehsi
EHS-International,Inc. 57
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Orange paint L1: ND N/A
10527-G-29 Boys Restroom G- Layer 2: White skim coat L2: ND N/A
12 Layer 3: GWB with paper L3: ND N/A
(mid wall)
Bare GWB w/paint (above
10527-G-30 Simulator G-1 1'x1' ACT w/ brown glue ND N/A
dots)
Layer 1: l'x 1' White ACT L1: ND N/A
10527-G-31 Corridor G-13 (with fissure pattern)
Layer 2: Brown glue dot L2: ND N/A
Layer 1: 4"x12" L1: ND N/A
Boys Restroom G-
Yellow/red ceramic wall
10527-G-3212 tile
Layer 2: Gray grout L2: ND N/A
Layer 3: Gray mortar L3: ND N/A
10527-G-33 Corridor G-13 Tan mastic w/paint ND N/A
beneath door sign
Layer 1: Tan/green paint L1: ND N/A
10527-G-34 Micro Computer G- Layer 2: White skim coat L2: ND N/A
7 Layer 3: Gray plaster L3: ND N/A
(beneath GWB wall)
Layer 1: Multi-colored L1: ND N/A
Micro Computer G- paint
10527-G-357 Layer 2: White skim coat L2: ND N/A
Layer 3: Gray plaster L3: ND N/A
(beneath GWB wall)
Layer 1: Multi-colored L1: ND N/A
paint
10527-G-36 Bus C.R Layer 2: White skim coat L2: ND N/A
Layer 3: Gray plaster L3: ND N/A
(beneath GWB wall)
10527-G-37 Bus Office G-10 White sink undercoat ND N/A
Gray window frame
10527-G-38 Bus C.R. G-4 caulking (on 5'x6' ND N/A
aluminum framed
window)
Layer 1: 4" Pink ceramic L1: ND N/A
10527-G-39 Corridor G-13 wall tile
Layer 2: Gray grout L2: ND N/A
Layer 3: White mortar L3: ND N/A
ehsi
58
EHS-International.Inc.
Limited Hazardous Materials Survey Report
Federal Way High School
• EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: l'xl' White ACT L1: ND N/A
10527-G- with paint (fissure
40QA Corridor G-13 pattern)
Layer 2: ACT debris L2: ND N/A
Layer 3: Brown glue dot L3: ND N/A
BLOCK H
Layer 1: 12"x12" Beige L1: ND N/A
10527-H- VCT (w/ brown and white
01QAX Main Corridor streaks)
Layer 2: Black mastic L2. 3% Chrysotile
on concrete
Layer 1: 12"x12" Beige Li: ND N/A
VCT (w/ brown and white
10527-H-02 Janitor's Closet streaks)
Layer 2: Black mastic L2: 3% Chrysotile
on concrete
Layer 1: White leveling L1: ND N/A
compound
10527-H-03 Janitor's Closet Layer 2: Gray leveling L2: ND N/A
compound
Layer 3: Black mastic L3: 3% Chrysotile
on concrete
Layer 1: Multi-colored L1: ND N/A
carpet w/ foam backing
Layer 2: Trace clear L2: ND N/A
mastic
10527-H-04 Office Layer 3: 12"x12" Beige L3: ND N/A
VCT (w/ brown and white
streaks)
Layer 4: Black mastic L4: 3% Chrysotile
on concrete
Layer 1: Multi-colored L1: ND N/A
10527-H-05 ASA Room carpet w/ foam backing
Layer 2: Tan mastic on L2: ND N/A
concrete
Layer 1: 12"x12" Multi- L1: ND N/A
East Entry, Main colored carpet squares w/
10527-H-06 Corridor rubber backing
Layer 2: Tan mastic on L2: ND N/A
concrete
ehsi
ENS-International.Inc. 59
i
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
L1: ND N/A
Layer 1: 1"x1" Beige and
gray ceramic floor tile L2: ND N/A
10527-H-07 Grooming 706 Layer 2: Trace gray grout
Layer 3: Light gray mortar L3: ND N/A
Layer 4: Beige mastic
L4: ND N/A
Layer 1: 1"xl" Beige L1: ND N/A
ceramic cove base tile
10527-H-08 Grooming 706 Layer 2: Gray grout L2: ND N/A
Layer 3: Light Gray L3: ND N/A
mortar
Layer 1: 4" Gray cove L1: ND N/A
10527-H-09 Main Corridor base
Layer 2: Tan mastic L2: ND N/A
Layer 1: Maroon colored L1: ND N/A
10527-H- mastic
Room 704
10QA Layer 2: Wood from roof L2: ND N/A
truss
10527-H-11 Room 705 2'x4' SACT w/ pin hole ND N/A
and worm track pattern
Layer 1: Silver foil Ll: ND N/A
10527-H-12 Room 704 Layer 2: Light brown L2: ND N/A
paper (batt insulation)
w/mastic
L1: ND N/A
Layer 1: Silver/gray cloth
10527-H-13 Grooming 706 Layer 2: Gray cloth L2: ND N/A
Layer 3: Silver/gray cloth L3: ND N/A
Layer 1: 1'x1' White ACT L1: ND N/A
(w/ pin hole and worm
10527-H-14 Main Corridor track pattern) w/ paint
Layer 2: Beige glue dot L2: ND N/A
Layer 3: JC w/ paper L3: ND N/A
Layer 4: GWB (ceiling) L4: ND N/A
10527-H-15 Main Corridor GWB (mid ceiling) ND N/A
10527-H-16 Main Corridor GWB (mid ceiling) ND N/A
10527-H-17 Room 704 Black sink undercoat ND N/A
Layer 1: 4" Black cove L1: ND N/A
base
10527-H-18 Room 704 Layer 2: Cream colored L2:ND N/A
mastic
Layer 3: Tan mastic L3: ND N/A
e s .. 60
ENS-International,Inc.
! •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: 4"Tan cove base L1: ND N/A
10527-H-19 Office Layer 2: Tan mastic
L2: ND N/A
Layer 1: White skim coat L1: ND N/A
10527-H-20 Main Corridor w/ paint
Layer 2: JC w/ paint L2: ND N/A
Layer 3: GWB (mid wall) L3: ND N/A
10527-H-21 Room 704 GWB w/ paint and paper ND N/A
(mid wall)
10527-H-22 ASA Room GWB w/ paint and paper ND N/A
(mid wall)
Layer 1: JC w/ paint L1: ND N/A
10527-H-23 Room 705 Layer 2: GWB w/ paper L2: ND N/A
(corner)
Layer 1: White skim coat L1: ND N/A
10527-H-24 Main Corridor, NE w/ paint
Corner Layer 2: GWB w/ paper L2: ND N/A
(mid wall)
Layer 1: White skim coat L1: ND N/A
10527-H-25 Main Corridor, S. w/ paint
Wall Layer 2: GWB w/ paper L2: ND N/A
(mid wall)
Layer 1: White skim coat L1: ND N/A
10527-H-26 Main Corridor w/ paint
Outside Room 704 Layer 2: GWB, w/ paper L2: ND N/A
(mid wall)
Layer 1: White skim coat L1: ND N/A
10527-H-27 Central Corridor w/ paint
Layer 2: JC w/ paint L2: ND N/A
Layer 3: GWB (mid wall) L3: ND N/A
Layer 1: Cloth covering w/ L1: ND N/A
10527-H-28 Office mastic
Layer 2: GWB w/ paper L2: ND N/A
Layer 1: White caulking L1: ND N/A
Layer 2: White grout L2: ND N/A
10527-H-29 ASA Room Layer 3: Gray mortar L3: ND N/A
(beneath ceramic window
sill tiles)
BLOCK J
Layer 1: White skim coat L1: ND N/A
10527-J-01 Corridor J-11 w/ paint
Layer 2: Gray plaster L2: ND N/A
Layer 1: JC w/ paint L1: ND N/A
10527-J-02 Corridor J-11 Layer 2: GWB w/ paper L2: ND N/A
(ceiling at seam)
ehsi
EHS-International.Inc. 61
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: JC w/ paint L1: ND N/A
10527-3-03 Girls J-3 Layer 2: GWB w/ paper L2: ND N/A
(ceiling at seam)
Layer 1: Yellow carpet L1: ND N/A
mastic
10527-3-04 Math Classroom Layer 2: 9"x9" Brown/ L2: 3% Chrysotile
3-5 red VAT
Layer 3: Black mastic on L3: ND N/A
concrete
Layer 1: Yellow mastic L1: ND N/A
(beneath 12"x12" light
gray VCT)
Layer 2:Gray leveling L2: ND N/A
10527-3-05 Corridor J-11 compound
Layer 3: Light gray VCT L3: ND N/A
Layer 4: Yellow/Black L4: ND N/A
mastic
Layer 5: White leveling L5: ND N/A
compound
Layer 1: Dark gray mastic L1: ND N/A
(beneath 12"x12" light
gray VCT)
10527-3- Layer 2: Yellow mastic L2: ND N/A
06QA Corridor 3-11 Layer 3: 9"x9" Light L3: 2% Chrysotile
blue VAT (w/ white
streaks)
Layer 4: Black mastic L4: 3% Chrysotile
on concrete
Boy's Restroom ) Layer 1: White skim coat L1: ND L1: ND
10527-J-0714 w/ paint
Layer 2: Plaster ceiling L2: ND L2: ND
Layer 1: Yellow carpet L1: ND N/A
mastic
10527-3-08 Math Classroom Layer 2: 9"x9" Tan VAT L2: 3% Chrysotile
3-7 (w/ brown and yellow
streaks)
Layer 3: Black mastic L3: ND N/A
Layer 1: 1"x1" Brown L1: ND N/A
10527-J-09 Boy's Restroom 3- ceramic floor tile
14 Layer 2: Gray grout L2: ND N/A
Layer 3: Gray mortar L3: ND N/A
ehsi�► 62
EHS-International,Inc.
i •
Limited Hazardous Materials Survey Report
Federal Way High School
• EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Beige paint on 4" L1: ND N/A
white ceramic cove base
10527-J-10 Boy's Restroom J- Layer 2: Trace of brown L2: ND N/A
14 and yellow mastic
Layer 3: Gray plaster on L3: ND N/a
metal mesh
10527-J-11
Math
ath Classroom 3-
GWB w/ paper (mid wall) ND N/A
Math Classroom J- Layer 1: White skim coat L1: ND N/A
10527-J-12 8 w/ paint
Layer 2: Gray plaster L2: ND N/A
Layer 1: JC w/ paint L1: ND N/A
10527-3-13 Math Classroom 3- Layer 2: JC w/ paint L2: ND N/A
8 Layer 3: GWB w/ paper L3: ND N/A
(corner)
10527-J-14
Math
ath Classroom 3-
Gray g window glazing putty ND N/A
10527-J-15*4 Math Classroom J- Layer 1: 6" Red ceramic L1: ND N/A
9 window sill tile
Layer 2: Dark gray grout L2: ND N/A
Layer 3: Dark gray mortar L3:0.25% Chrysotile
10527-J-16 Attic Above Black flex duct ND N/A
Storage J-1
10527-3-17 Attic Above Green pipe dope ND N/A
Storage 3-1 (sprinkler fittings)
Layer 1: Cream colored L1: ND N/A
cove base mastic
Layer 2: JC w/ paint L2: ND N/A
10527-J-18 Janitor J-4 Layer 3: Residual brown L3: ND N/A
cove base mastic
Layer 4: White skim coat L4: ND N/A
w/ paint
Layer 5: Gray Plaster L5: ND N/A
BLOCK K
Layer 1: Yellow/tan carpet L1: ND N/A
mastic
10527-K-01 Math Office K-2 Layer 2: 9'x9" Red VAT L2. 3% Chrysotile
Layer 3: Black mastic on L3: ND N/A
concrete
Layer 1: Yellow carpet L1: ND N/A
10527-K-02 F.L. Classroom K-9 mastic
Layer 2: Gray leveling L2: ND N/A
compound on concrete
ehsi
ENS-International.Inc. 63
i •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: White skim coat L1: ND N/A
10527-K-03 F.L. Classroom K-9 w/ paint
Layer 2: Gray Plaster L2: ND N/A
Layer 1: White skim coat L1: ND N/A
10527-K-04 Math Office K-2 w/ paint
Layer 2: Gray Plaster L2: ND N/A
10527-K-05 Corridor K-5 Green pipe dope ND N/A
(sprinkler fittings)
10527-K-06 Office K-7 Black speaker coating ND N/A
w/paint
Layer 1: White ACT w/ L1: ND N/A
10527-K-07 Computer K-3 small and large hole
pattern
Layer 2: Black glue dot L2: ND N/A
Layer 1: Brown paper L1: ND N/A
Layer 2: Black mastic L2: ND N/A
10527-K-08 Computer K-3 Layer 3: Brown paper L3: ND N/A
(between wood beam and
plaster wall)
Layer 1: Brown cork L1: ND N/A
Math Classroom K- board
10527-K-09 8 Layer 2: White styrofoam L2: ND N/A
Layer 3: Tan glue dot L3: ND N/A
w/paint
Layer 1: JC w/ paint L1: ND N/A
10527-K-10 Office K-7 Layer 2: GWB w/ paper L2: ND N/A
(corner)
10527-K-11 Office K-7 GWB (mid wall) ND N/A
BLOCK L
Layer 1: 12"x12" Light L1: ND N/A
gray VCT (w/ white and
10527-L-01 Corridor L-6, North maroon streaks)
Layer 2: Tan/yellow L2: ND N/A
mastic on concrete
Layer 1: 12"x12" Light L1: ND N/A
Corridor L 6, gray VCT (w/ white and
10527-L-02 South maroon streaks)
Layer 2: Tan/yellow L2: ND N/A
mastic, on concrete
Corridor L-6,
Layer 1: 12"x12" Blue L1: ND N/A
10527-L-03VCT
South
Layer 2: Tan mastic L2: ND N/A
ehsi.. 64
EHS-International,Inc.
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: 1'x1' White ACT L1: ND N/A
(w/ pin hole and fissure
10527-L-04 Shop Classroom pattern) w/ paint
L7 Layer 2: Brown glue dot L2: ND N/A
Layer 3: JC L3: ND N/A
Layer 4: GWB (at seam) L4: ND N/A
Layer 1: 9"x9" Olive L1: 3% Chrysotile
10527-L-05 Ceramics Lab L-5 VAT
Layer 2: Black mastic L2: 3% Chrysotile
on concrete
Layer 1: 9"x9" Light L1: 2% Chrysotile
10527-L-06 Ceramics Lab L-5 olive VAT
Layer 2: Black mastic L2: 3% Chrysotile
on concrete
Layer 1: 12"x12" Light L1: ND N/A
gray VCT (w/ white and
10527-L-07 Storage L-4 maroon streaks)
Layer 2: Black mastic on L2: ND N/A
concrete
Layer 1: 2'x4' White SACT L1: ND N/A
10527-L-08 Corridor L-6 covering
Layer 2: 2'x4' SACT L2: ND N/A
Layer 1: 9"x9" Green L1: 3% Chrysotile
10527-L-09 Art Lab L-1 VAT (w/ beige streaks)
Layer 2: Black mastic L2: 3% Chrysotile
Layer 1: 4" Black cove L1: ND N/A
base
10527-L-10 Art Lab L-1 Layer 2: Cream colored L2: ND N/A
mastic
Layer 3: JC L3: ND N/A
10527-L-11 Corridor L-6 Plaster (ceiling) ND N/A
10527-L-12 Corridor L-6 Plaster (ceiling) ND N/A
10527-L-13 Corridor L-6 Plaster (ceiling) ND N/A
Layer 1: Skim coat L1: ND N/A
10527-L-14 Corridor L-6 w/paint
Layer 2: Plaster L2: ND N/A
Layer 1: Skim coat L1: ND N/A
10527-L-15 Corridor L-6 w/paint
Layer 2: Plaster L2: ND N/A
Layer 1: Skim coat L1: ND N/A
10527-L-16 Corridor L-6 w/paint
Layer 2: Plaster L2: ND N/A
•
ehsi..6
EHS-Intemational,Inc. 65
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: JC L1: 0.5% N/A
10527-L-17*5 Corridor L-6 Layer 2: GWB (mid L2: ND N/A
ceiling)
Layer 1: 1'x1' White ACT L1: ND N/A
(w/ pin hole and fissure
10527-L-18 Corridor L-6 pattern) w/ paint
Layer 2: Brown glue dot L2: ND N/A
Layer 3: GWB (at seam) L3: ND N/A
Layer 1: 1'x1' White ACT L1: ND N/A
cover
10527-L- Art Lab L-1 Layer 2: 1'x1' Brown ACT L2: ND N/A
19QA interior
Layer 3: Brown vapor L3: ND N/A
barrier w/ black mastic
2'x4' White SACT (w/
10527-L-20 Art Lab L-1 worm track and pin hole ND N/A
pattern)
Layer 1: 4"Tan cove base L1: ND N/A
10527-L-21 Storage L-3 Layer 2: Cream colored L2: ND N/A
mastic
Layer 3: Brown mastic L3: ND N/A
Layer 1: 1'x1' White ACT L1: ND N/A
w/ small pin hole covering
10527-L-22 Office L-8 Layer 2: 1'x1' Brown ACT L2: ND N/A
interior
Layer 3: Brown glue dot
Layer 1: 4"Tan CB L1: ND N/A
Layer 2: Cream colored L2: ND N/A
10527-L-23 Corridor L-6 mastic
Layer 3: Black cove base L3: ND N/A
Layer 4: Brown mastic L4: ND N/A
10527-L-24 Shop Classroom L- Layer 1: Blue/gray carpet
L1: ND N/A
7 Layer 2: Tan mastic L1: ND N/A
Layer 1: Blue/gray carpet Ll: ND N/A
Layer 2: Tan mastic L2: ND N/A
Layer 3: White leveling L3: ND N/A
10527-L-25 Office L-8 compound
Layer 4: 9"x9" Red VAT L4: 3% Chrysotile
Layer 5: Black mastic
on concrete L5: 3% Chrysotile
ehsi 66
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
• EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Red sheet vinyl L1: ND N/A
10527-L- Layer 2: Black asphaltic L2: ND N/A
26QAX Metal Shop backing
Layer 3: Black mastic L3: 4% Chrysotile
on concrete
Layer 1: Red sheet vinyl L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
10527-L-27 Wood Shop Area backing
Layer 3: Black mastic
L3: 3% Chrysotile
on concrete
Wood Shop Layer 1: JC L1: ND N/A
10527-L-28 Layer 2: GWB w/ paper L2: ND N/A
Mezzanine Storage (ceiling seam)
10527-L-29 Wood Shop GWB w/ paper (mid ND N/A
Mezzanine Storage ceiling)
10527-L-30 Auto Shop L-15 GWB w/ paper and paint ND N/A
(mid ceiling)
10527-L-31 Auto Shop L-15 Black/Gray expansion ND N/A
joint sealant
Layer 1: White paint on L1: ND N/A
10527-L-32 Corridor L-6, red paint
South Layer 2: Beige wall L2: ND N/A
texturing
Layer 1: White paint on L1: ND N/A
10527-L-33 Corridor L-6, North red paint
Layer 2: Beige wall L2: ND N/A
texturing
10527-L-34 Auto Shop L15 Gray CMU mortar w/ paint ND N/A
10527-L-35 Corridor L-6 Layer 1: Red brick L1: ND N/A
Layer 2: Gray mortar L2: ND N/A
Layer 1: 1"xl" Off-white L1: ND N/A
10527-L-36 Corridor L-6 ceramic wall tile L2: ND N/A
Layer 2: Beige grout L3: ND N/A
Layer 3: Dark gray mortar
Layer 1: JC w/ paint L1: ND N/A
10527-L-37 Storage L-3 Layer 2: GWB w/ paint L2: ND N/A
and paper (mid wall)
10527-L-38 Ceramics Lab L-5 GWB w/ paint and paper ND N/A
Layer 1: JC w/ paint and L1: 0.25% Chrysotile
10527-L-39*5 Art Lab L-1 paper
Layer 2: GWB w/ paper L2: ND N/A
10527-L-40 Art Lab L-1 Gray window glazing putty ND N/A
w/paint
ehsi
EHS-International,Inc. 67
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527 •
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Corridor L-6 Gray caulking w/paint
10527-L-41 South around metal seismic 3% Chrysotile
wall bracket
Layer 1: Beige soft L1; ND N/A
10527-L-42 Corridor L-6 caulking w/paint
Layer 2: Beige hard L2: ND N/A
caulking
BLOCK M
Layer 1: 9"x9" Olive L1: 3% Chrysotile
colored VAT (w/ pink
10527-M-01 Choral M-26 and beige streaks)
Layer 2: Black mastic L2: 2% Chrysotile
on concrete
Layer 1: 8" Black cove L1: ND N/A
10527-M-02 Choral M-26 base
Layer 2: Brown mastic L2: ND N/A
Layer 1: 12"x12" Light L1: ND N/A
gray VCT (w/ white and
10527-M-03 Corridor M-12 gray streaks)
Layer 2: Yellow mastic L2: ND N/A
Layer 3: Gray leveling L3: ND N/A
compound
Layer 1: 12"x12" Blue L1: ND N/A
VCT
10527-M-04 Corridor M-1 Layer 2: Yellow mastic L2: ND N/A
Layer 3: Trace black L3: 2% Chrysotile
mastic on concrete
Layer 1: 4"Tan cove base L1: ND N/A
10527-M-05 Corridor M-12 Layer 2: Cream colored L2: ND N/A
mastic
Layer 3: Brown mastic L3: ND N/A
Layer 1: 4" Black cove L1: ND N/A
base
10527-M-06 Choral M-26 Layer 2: Cream colored L2: ND N/A
mastic
Layer 3: Brown mastic L3: ND N/A
Layer 1: 1'x1' White ACT L1: ND N/A
w/ pin hole pattern
10527-M-07 Storage M-34 Layer 2: Brown glue dot L2: ND N/A
Layer 3: GWB w/ paper, L3: ND N/A
ceiling
ehs .. 68
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
• EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: l'x1' White ACT L1: ND N/A
w/ pin hole pattern L2: ND N/A
Layer 2: Brown glue dot L3: ND N/A
10527-M-08 Entry M-18 Layer 3: Silver seam tape
Layer 4: Gray seam tape L4: ND N/A
mastic
Layer 5: GWB w/ paper L5: ND N/A
(ceiling seam)
Layer 1: Blue/gray carpet L1: ND N/A
Layer 2: Tan mastic L2: ND N/A
Band Room- Layer 3: 9"x9" Olive L3: 3% Chrysotile
10527-M-09 Practice 3, M-29 colored VAT (w/ pink
and beige streaks)
Layer 4: Black mastic L4: 2% Chrysotile
on concrete
Layer 1: Blue/gray carpet
L1: ND N/A
10527-M-10 Band Room M-17 Layer 2: Tan mastic L2: ND N/A
Layer 3: Trace black L3: ND N/A
mastic
L1: ND N/A
Layer 1: Blue/gray carpet
10527-M-11 Band Room- Layer 2: Tan mastic L2: ND N/A
Practice 2, M-15 Layer 3: 9"x9" Red VAT L3: 3% Chrysotile
Layer 4: Black mastic
L4: ND N/A
Layer 1: 12"x12" Light L1: ND N/A
Photography Lab gray VCT (w/ maroon and
10527-M-12 M-38 white streaks)
Layer 2: Black mastic L2. 3% Chrysotile
on concrete
Layer 1: 1"xl" Blue L1: ND N/A
10527-M-13 Men's Restroom ceramic floor tile
M-3 Layer 2: Gray grout L2: ND N/A
Layer 3: White mortar L3: ND N/A
Layer 1: 1"x1" Pink L1: ND N/A
10527-M-14 Women Restroom ceramic floor tile
M-4 Layer 2: Gray grout L2: ND N/A
Layer 3: White mortar L3: ND N/A
ehsi
EHS-International,Inc. 69
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527 •
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Yellow VAT L1: 2% Chrysotile
Science (w/ brown and black
10527-M-15 streaks)
Classroom M-11
Layer 2: Black mastic L2: 3% Chrysotile
on concrete
Layer 1: 12"x12" Light L1: ND N/A
blue VCT (w/ blue and
10527-M-16 Chemistry Lab M-6 white streaks)
Layer 2: Tan mastic L2: ND N/A
Layer 3: Gray VCT L3: ND N/A
Layer 4: Black mastic L4: ND N/A
Layer 1: 9"x9" Olive L1: 3% Chrysotile
10527-M-17 Physics Lab M-7 colored VAT (w/ black
and beige streaks)
Layer 2: Black mastic L2: ND N/A
10527-M- Layer 1: White skim coat L1: ND N/A
18QA Mechanical M-3 w/ paint
Layer 2: Plaster (ceiling) L2: ND N/A
Layer 1: White skim coat L1: ND N/A
10527-M-19*6 Storage M-2 w/ paint
Layer 2: Plaster (ceiling) L2: .75% Chrysotile
Layer 1: White skim coat L1: ND N/A
10527-M-20*6 Band M-17 w/ paint
Layer 2: Plaster (mid wall) L2: 0.5% Chrysotile
Layer 1: White skim coat L1: ND N/A
10527-M-21*6 Storage M-2 w/ paint
Layer 2: Plaster (mid wall) L2: 0.75% Chrysotile
Layer 1: White paint L1: ND N/A
L2: ND N/A
Layer 2: Beige wall
10527-M-22 Corridor M-1 texturing L3: ND N/A
Layer 3: Red paint L4: ND N/A
Layer 4: Trace CMU debris
Layer 1: White paint L1: ND N/A
Corridor M-12,
Layer 2: Beige wall L2: ND N/A
10527-M-23 texturing L3: ND N/A
South Layer 3: Red paint
Layer 4: Trace CMU debris L4: ND N/A
Layer 1: White paint L1: ND N/A
L2: ND N/A
Corridor M-12,
Layer 2: Beige wall
10527-M-24 texturing L3: ND N/A
Middle Layer 3: Red paint
Layer 4: Trace CMU debris L4: ND N/A
ehsi4 70
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: JC w/ beige paint L1: ND N/A
10527-M-25 Corridor M-6 Layer 2: GWB w/ paper
(corner wall) L2: ND N/A
10527-M-26 Band Room M-17 GWB w/ paint and paper ND N/A
(mid wall)
Layer 1: JC w/ paper L1: ND N/A
10527-M-27 Corridor M-12 Layer 2: GWB w/ paper L2: ND N/A
(ceiling edge)
10527-M-28 Corridor M-12 GWB w/ paper (mid wall) ND N/A
10527-M-29 Mechanical M-5 Tan pipe dope ND N/A
Layer 1: 4"x4" Beige L1: ND N/A
Boy's Restroom M ceramic wall tile
10527-M-303 Layer 2: Beige grout L2: ND N/A
Layer 3: Tan mastic L3: ND N/A
Layer 4: Gray mortar L4: ND N/A
Layer 1: Gray door frame L1: ND N/A
10527-M-31 Corridor M-12 caulking
Layer 2: White door frame L2: ND N/A
caulking
Layer 1: Beige paint L1: ND N/A
10527-M-32 Entry to M-18 Layer 2: Red wall panel L2: ND N/A
Layer 3: White wall panel L3: ND N/A
10527-M-33 Instrument Gray sink undercoat ND N/A
Storage M-19
Layer 1: 1'z1' White ACT L1: ND N/A
10527-M- w/ large and small pin
34QA Band M-17 hole
Layer 2: Brown glue dot L2: ND N/A
on plaster wall
TUNNELS
Layer 1: Gray/Off- L1: 8% Chrysotile
white TSI debris
10527-T-01. Utility Tunnel Layer 2: Pink material TSI L2: ND N/A
L/M-NW End debris
Layer 3: White foamy L3: ND N/A
Material
10527-T-02 Utility Tunnel L/M- Black/brown asphaltic
N-S Intersection paper debris ND N/A
Utility Tunnel Army green/gray
10527-T-03 L/M, At Tunnel mastic w/ debris on 3% Chrysotile
Hatch cable bracket
ehsi•
EHS-International,Inc, 71
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Gray fibrous L1: 60% Chrysotile
Utility Tunnel material/paper
10527-T- A/B Boiler Room Layer 2: Black asphaltic L2: 22% Chrysotile
04QAx Tunnel vapor barrier, between
concrete and wood
forms
Utility Tunnel A/B Layer 1: Debris L1: ND N/A
10527-05 Boiler Room Layer 2: GWB w/paper L2: ND N/A
Tunnel
Utility Tunnel Layer 1: Concrete debris L1: ND N/A
10527-T-06 A/B Boiler Room Layer 2: TSI on L2: 56% Chrysotile
Tunnel abandoned pipe (8"
OD)
Utility Tunnel A/B Layer 1: Black asphaltic L1: ND N/A
10527-T-07 Boiler Room pipe coating
Tunnel Layer 2: Gray/white L2: ND N/A
tunnel debris
Block G Crawl Layer 1: 3C L1: 3% Chrysotile
10527-T-08 Space Layer 2: GWB (access L2: ND N/A
door)
CONCRETE SLAB CORING
Layer 1: Grout and L1: ND N/A
10527-62513- Block A2-Girls concrete debris
01 Locker Room Layer 2: Trace black L2: ND N/A
mastic
Layer 1: Black plastic L1: ND N/A
10527-62513- Block G-Janitor vapor barrier w/ fibrous
material
02 Closet
Layer 2: Brown paper L2: ND N/A
vapor barrier
EXTERIOR
10527-EXT- Industrial Art, White caulking w/paint 2% Chrysotile
01 Exterior on steel columns
Industrial Art, Brown high voltage
10527-EXT-02 Exterior conduit penetration ND N/A
sealant
10527-EXT- Industrial Art, Gray door frame
03QA Exterior caulking w/paint 2% Chrysotile
(8x10 roll-up door)
Auto Shop, Gray window glazing putty ND N/A
10527-EXT-04 Exterior (on 6'x10' roll-up door )
10527-EXT-05 Auto Shop, White door trim caulking ND N/A
Exterior (3'x8' roll up door)
ehsi 72
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
• EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Tan/gray door frame
10527-EXT- Block F, Exterior caulking w/paint 2% Chrysotile
06 (8'x14'on double
doors)
10527-EXT-07 Block F, Exterior Beige Shotcreteirl ND N/A
West Side
Layer 1: Tan window L1: 2% Chrysotile
10527-EXT- Block F, Exterior frame caulking(4'x18')
08 West Side Layer 2: Brown wood
debris L2: ND N/A
10527-EXT-09 Block F, Exterior Graywindow glazing
West Side 9 9 putty ND N/A
Layer 1: Black asphaltic L1: ND N/A
Block F, Exterior paper (behind wood
10527-EXT-10 column)
West Side
Layer 2: Brown wood L2: ND N/A
debris
10527-EXT-11 Block K, Exterior Beige shotcrete ND N/A
10527-EXT-12 Block H, Exterior Beige shotcrete ND N/A
10527-EXT-13 Block F, Exterior Beige shotcrete ND N/A
West Side
10527-EXT-14 Block J, Exterior Beige shotcrete ND N/A
South Side
10527-EXT-15 Block E, Exterior Beige shotcrete ND N/A
East Side
10527-EXT-16 Block E, Exterior Beige shotcrete ND N/A
East Side
Block E, 2001
10527-EXT-17 addition, Exterior Beige EFIS w/paint ND N/A
East Side
Block B, 2001
10527-EXT-18 addition, Exterior Beige EFIS w/paint ND N/A
East Side
Block B, 2001
10527-EXT-19 addition, Exterior Beige EFIS w/ yellow/blue ND N/A
East Side paint
Layer 1: Tan/beige EFIS L1: ND N/A
10527-EXT-20 Block A, Exterior Layer 2: White styrofoam L2: ND N/A
insulation
10527-EXT-21 Block A, Exterior Tan/beige EFIS w/paint ND N/A
East Side
Block A Exterior Layer 1: Tan/beige EFIS Li: ND N/A
10527-EXT-22 North Side Layer 2: Beige building L2: ND N/A
seam caulking
ehsi
ENS-International.Inc. 73
i i
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
10527-EXT-23 Block A, Exterior Tan/beige EFIS ND N/A
North Side
10527-EXT-24 Block A, Exterior Tan/beige EFIS ND N/A
West Side
10527-EXT-25 Block A, Exterior Tan/beige EFIS ND N/A
West Side
Block B, Exterior Layer 1: Tan/beige EFIS L1: ND N/A
10527-EXT-26 West Side Layer 2: Beige building L2: ND N/A
seam caulking
Central Layer 1: Gray paper L1: ND N/A
10527-EXT-27 Greenhouse Layer 2: Beige caulking L2: ND N/A
(on greenhouse frame)
10527-EXT- Block M, Exterior Gray window frame 2% Chrysotile
28 caulking (3'x5')
10527-EXT-29 Block M, Exterior Beige EFIS w/paint ND N/A
East Wall
10527-EXT-30 Block M, Exterior Beige EFIS w/paint ND N/A
East Wall
10527-EXT-31 Block M, Exterior Beige EFIS w/paint ND N/A
East Wall
Block K, Exterior Layer 1: JC w/ paper L1: ND N/A
10527-EXT-32 Covered Walkway Layer 2: GWB w/ paper L2: ND N/A
West Side (soffit seam)
Block K, F, G, H Layer 1: JC w/ paint L1: ND N/A
10527-EXT-33 and K, Exterior Layer 2: GWB w/ paper L2: ND N/A
Covered Walkway (soffit seam)
Block E, F, G, H GWB w/ paint and paper
10527-EXT-34 and K, Exterior ND N/A
(mid soffit)
Covered Walkway
10527-EXT- Block E, F, G, H Layer 1: JC w/ paint L1: ND N/A
35QA and K, Exterior Layer 2: GWB w/ paper L2: ND N/A
Covered Walkway (mid-soffit)
Layer 1: JC w/ fibrous L1: ND N/A
10527-EXT-36 Block D, Exterior material and paint
Layer 2: GWB w/ paper L2: ND N/A
(soffit seam)
10527-EXT-37 Block D, Exterior GWB w/ Ppp
and masticaint(mid soffit)andaer ND N/A
10527-EXT-38 Block D, Exterior GWB w/ paint and paper ND N/A
and mastic (mid soffit)
ehsi 74
ENS-International,Inc.
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLINGAND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Black asphaltic L1: ND N/A
felt
10527-EXT- Block C, Exterior Layer 2: Black asphaltic L2: 2% Chrysotile
39 tar
Layer 3: Concrete debris L3: ND N/A
(on foundation wall)
Layer 1: Black asphaltic L1: ND N/A
felt
10527-EXT- Block C, Exterior Layer 2: Black asphaltic L2: 3% Chrysotile
40 tar
Layer 3: Concrete debris L3: ND N/A
(on foundation wall)
Layer 1: Black asphaltic L1: ND N/A
felt
10527-EXT- Block C, Exterior Layer 2: Black asphaltic L2: 3% Chrysotile
41 tar
Layer 3: Concrete debris L3: ND N/A
(on foundation wall)
ROOF
Layer 1: Black asphaltic L1: ND N/A
3-tab shingle
Layer 2: Black asphaltic L2: ND N/A
Community Pool vapor barrier
10527-R-01 Building, South Layer 3: Black asphaltic L3: ND N/A
Side, Low Roof vapor barrier
Layer 4: Black asphaltic L4: ND N/A
vapor barrier
Layer 5: Black asphaltic L5: ND N/A
vapor barrier (on wood)
Layer 1: Black asphaltic Li: ND N/A
3-tab shingle
Layer 2: Black asphaltic L2: ND N/A
vapor barrier
10527-R-02 Community Pool, Layer 3: Black asphaltic L3: ND N/A
Central High Roof vapor barrier
Layer 4: Black asphaltic L4: ND N/A
vapor barrier
Layer 5: Black asphaltic L5: ND N/A
vapor barrier (on wood)
Layer 1: Black asphaltic Li: ND N/A
10527-R-03 Community Pool, 3-tab shingle
NW Side Low Roof Layer 2:Black asphaltic L2: ND N/A
vapor barrier (on wood)
ehsi♦4 �s
EHS-International,Inc.
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Black asphaltic Li: ND N/A
built-up roofing w/ sand
Layer 2: Black asphaltic L2: ND N/A
built-up roofing w/ sand
Layer 3: Black asphaltic L3: ND N/A
built-up roofing w/ sand
Layer 4: Brown insulation L4: ND N/A
Layer 5: Black asphaltic L5: ND N/A
vapor barrier
Layer 6: Yellow foam L6: ND N/A
insulation
Layer 7: Black asphaltic L7: ND N/A
Community Pool, vapor barrier
10527-R-04 Central Flat Roof, Layer 8: White foam L8: ND N/A
East insulation
Layer 9: Black asphaltic L9: ND N/A
vapor barrier
Layer 10: Black asphaltic L10: ND N/A
vapor barrier
Layer 11: Yellow foam L11: ND N/A
insulation
Layer 12: Black asphaltic L12: ND N/A
vapor barrier
Layer 13: Black asphaltic L13: ND N/A
vapor barrier
Layer 14: White foam L14: ND N/A
insulation
Layer 1: Black asphaltic L1: ND N/A
built-up roofing w/ sand
Layer 2: Black asphaltic L2: ND N/A
built-up roofing w/ sand
Layer 3: Black asphaltic L3: ND N/A
built-up roofing w/ sand
Layer 4: Brown insulation L4: ND N/A
Layer 5: Black asphaltic L5: ND N/A
Community Pool, vapor barrier
10527-R-05 Central Flat Roof, Layer 6: Yellow foam L6: ND N/A
West insulation
Layer 7: Black asphaltic L7: ND N/A
vapor barrier
Layer 8: White foam L8: ND N/A
insulation
Layer 9: Black asphaltic L9: ND N/A
vapor barrier
Layer 10: Black asphaltic L10: ND N/A
vapor barrier
ehsi..
76
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULKSAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGHSCHOOL
SAMPLES
AMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 11: Yellow foam L11: ND N/A
insulation
Layer 12: Black asphaltic L12: ND N/A
vapor barrier
Layer 13: Black asphaltic L13: ND N/A
vapor barrier
Layer 14: White foam L14: ND N/A
insulation
Community Pool, Black asphaltic sealant on
Central Flat Roof, ND N/A
10527-R-06 West roof vent
Community Pool, Black asphaltic tar on roof
Central Flat Roof, ND N/A
10527-R-07 West flashing
Community Pool, Gray seam sealant w/
Central Flat Roof, paint and debris on roof ND N/A
10527-R-08 West flashing
Community Pool, Layer 1: Clear window L1: ND N/A
Central Flat Roof, frame caulking
WestLayer 2: Brown window L2: ND N/A
i0527-R-09frame caulking w/paint
Community Pool, Black caulking w/paint
Central Flat Roof, around 14" exhaust fan ND N/A
10527-R-10 West
Community Pool, Layer 1: Black caulking L1: ND N/A
Central Flat Roof, Layer 2: Beige caulking L2: ND N/A
10527-R-11 West around wood panels
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built up roofing
Block A Roof, NW Layer 3: Black asphaltic L3: ND N/A
10527-R-12 Low Roof, West vapor barrier
Side Layer 4: Black asphaltic L4: ND N/A
vapor barrier
Layer 5: Brown paper (on L5: ND N/A
wood)
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing
Block A Roof, NW Layer 3: Black asphaltic L3: ND N/A
10527-R-13 Low Roof, East vapor barrier
Side Layer 4: Black asphaltic L4: ND N/A
vapor barrier
Layer 5: Brown paper (on L5: ND N/A
wood)
ehsi 4
77
ENS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
•
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
Block A, NW Low built-up roofing w/ sand
10527-R-14 Roof, N. Parapet Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Layer 4: Black asphaltic L4: ND N/A
vapor barrier (on wood)
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing w/ sand
Block A Roof, N. Layer 3: Black asphaltic L3: ND N/A
10527-R-15 Side High Roof. W. vapor barrier
Side Layer 4: Black asphaltic L4: ND N/A
vapor barrier
Layer 5: Brown paper (on L5: ND N/A
wood)
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing w/ sand
Block A Roof, N. Layer 3: Black asphaltic L3: ND N/A
10527-R-16 Side High Roof. E. vapor barrier
Side Layer 4: Black asphaltic L4: ND N/A
vapor barrier
Layer 5: Brown paper (on L5: ND N/A
wood)
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing w/ sand
Block A Roof, N. Layer 3: Black asphaltic L3: ND N/A
10527-R-17 Side High Roof. E. vapor barrier
Side, Parapet Layer 4: Black asphaltic L4: ND N/A
vapor barrier
Layer 5: Beige paint (on L5: ND N/A
concrete)
?s"/.,
ENS-International,Inc. 78
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Black asphaltic L1: ND N/A
built-up roofing L2: ND N/A
Layer 2: Brown insulation
Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Block A Roof, Layer 4: Yellow foam L4: ND N/A
Central Dome insulation
Shaped Roof W. Layer 5: Black asphaltic L5: ND N/A
Side vapor barrier
Layer 6: Black asphaltic L6: ND N/A
tar
Layer 7: Yellow foam L7: ND N/A
insulation
Layer 8: White paper (on L8: ND N/A
10527-R-18 wood)
Layer 1: Black asphaltic L1: ND N/A
built-up roofing
Layer 2: Brown insulation L2: ND N/A
Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Block A Roof, Layer 4: Yellow foam L4: ND N/A
Central Dome insulation
10527-R-19 Shaped Roof, Layer 5: Black asphaltic L5: ND N/A
Center vapor barrier
Layer 6: Black asphaltic L6: ND N/A
tar
Layer 7: Yellow foam L7: ND N/A
insulation
Layer 8: White paper (on L8: ND N/A
wood)
Layer 1: Black asphaltic L1: ND N/A
built-up roofing
Layer 2: Brown insulation L2: ND N/A
Layer 3: Black asphaltic L3: ND N/A
Block A Roof, vapor barrier
Central Dome Layer 4: Yellow foam L4: ND N/A
10527-R-20 Shaped Roof E. insulation
Side Layer 5: Black asphaltic L5: ND N/A
vapor barrier
Layer 6: Black asphaltic L6: ND N/A
tar
Layer 7: Yellow foam L7: ND N/A
insulation (on wood)
ehsi..�
EHS-International,Inc. 79
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527 r
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % , ASBESTOS
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing L3: ND N/A
Layer 3: Brown insulation
Layer 4: Black asphaltic L4: ND N/A
Block A Roof, W. vapor barrier
Side Highest Roof, Layer 5: Yellow foam L5: ND N/A
N. Side insulation
Layer 6: Black asphaltic L6: ND N/A
vapor barrier
Layer 7: Black asphaltic L7: ND N/A
tar
Layer 8: White paper, on L8: ND N/A
10527-R-21 wood
Layer 1: Silver coat Li: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing
Layer 3: Brown insulation L3: ND N/A
Layer 4: Black asphaltic L4: ND N/A
Block A Roof, W. vapor barrier
10527-R-22 Side Highest Roof, Layer 5: Yellow foam L5: ND N/A
S. Side insulation
Layer 6: Black asphaltic L6: ND N/A
vapor barrier
Layer 7: Black asphaltic L7: ND N/A
tar
Layer 8: White paper (on L8: ND N/A
wood)
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing N/A
Layer 3: Brown insulation L3: ND
Layer 4: Black asphaltic L4: ND N/A
Block A Roof, E. vapor barrier
10527-R-23 Side Highest Roof, Layer 5: Yellow foam L5: ND N/A
S. Side, over insulation
Corridor Layer 6: Black asphaltic L6: ND N/A
vapor barrier
Layer 7: Black asphaltic L7: ND N/A
tar
Layer 8: White paper (on L8: ND N/A
wood)
efts'/.. 80
EH S-International.Inc.
t • •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing
Layer 3: Brown insulation L3: ND N/A
Layer 4: Black asphaltic L4: ND N/A
Block A Roof, E. vapor barrier
10527-R-24 Side Highest Roof, Layer 5: Yellow foam L5: ND N/A
N. Side, over insulation
Corridor Layer 6: Black asphaltic L6: ND N/A
vapor barrier
Layer 7: Black asphaltic L7: ND N/A
tar
Layer 8: White paper, on L8: ND N/A
wood
Block A Roof N. Brown/gray caulking
10527-R-25 Side High Roof w/paint on parapet ND N/A
flashing
Layer 1: Silver paint L1: 2% Chrysotile
10527-R-26 Block A Roof, N. Layer 2: Black asphaltic L2: 4% Chrysotile
Side High Roof tar(at roof vent base)
Layer 1: Silver Coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing
10527-R-27 Block A Roof, N. Layer 3: Black asphaltic L3: ND N/A
Side High Roof tar
Layer 4: Black asphaltic L4: ND N/A
vapor barrier, at roof curb
(roof vent base)
Layer 1: Silver Coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
Block B Roof, W.
built-up roofing
10527-R-28 Side Lower Roof Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Layer 4: Brown paper L4: ND N/A
vapor barrier (on wood)
10527-R-29 Block B Roof, W. Gray duct seam sealant ND N/A
Side Lower Roof
ehsi
EHS-International,Inc. 81
• • . '
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Silver Coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing
Layer 3: Black asphaltic L3: ND N/A
tar
Layer 4: Brown insulation L4: ND N/A
Block B Roof, Layer 5: Black asphaltic L5: ND N/A
10527-R-30 Central High Roof, vapor barrier
W. Layer 6:Yellow foam L6: ND N/A
insulation
Layer 7: Black asphaltic L7: ND N/A
vapor barrier
Layer 8: Yellow foam L8: ND N/A
insulation
Layer 9: White paper L9: ND N/A
Layer 1: Silver coat L1: ND N/A
Block B Roof, Layer 2: Black asphaltic L2: ND N/A
10527-R-31 Central High Roof, built-up roofing
E Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Layer 4: Brown paper L4: ND N/A
Block B Roof, Layer 1: Black asphaltic L1: ND N/A
10527-R-32 Central Low Roof built-up roofing w/ sand
Layer 2: Brown insulation L2: ND N/A
Layer 1; Black asphaltic L1: ND N/A
built-up roofing w/ sand
Layer 2: Brown insulation L2: ND N/A
Layer 3: Black asphaltic L3: ND N/A
tar
Block B Roof, E. Layer 4: Brown insulation L4: ND N/A
10527-R-33 Side High Roof, S. Layer 5: Yellow foam L5: ND N/A
Side insulation
Layer 6: Black asphaltic L6: ND N/A
vapor barrier
Layer 7: Yellow foam L7: ND N/A
insulation
Layer 8: Gray paper vapor L8: ND N/A
barrier (on wood)
ehsi i. 82
EHS-International,Inc.
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1; Black asphaltic L1: ND N/A
built-up roofing w/ sand
Layer 2: Brown insulation L2: ND N/A
Layer 3: Black asphaltic L3: ND N/A
tar
Block B Roof, E. Layer 4: Brown insulation L4: ND N/A
10527-R-34 Side High Roof, N. Layer 5: Yellow foam L5: ND N/A
Side insulation
Layer 6: Black asphaltic L6: ND N/A
vapor barrier
Layer 7: Yellow foam L7: ND N/A
insulation
Layer 8: Gray paper vapor L8: ND N/A
barrier (on wood)
Block B Roof, Tan/beige seam caulking
10527-R-35 between Block w/paint ND N/A
A&B
10527-R-36 Block B Roof Black asphaltic tar w/paint ND N/A
Central Low Roof on metal flashing
10527-R-37 Block B Roof Tan air vent frame ND N/A
Central Low Roof caulking w/paint
10527-R-38 Block C Roof, S. Black sealant w/paint ND N/A
Side around brick wall infill
10527-R-39 Block C Roof, S. Gray/tan sealant w/paint ND N/A
Side around brick wall infill
10527-R-40 Block C Roof, S. Gray/tan sealant on metal ND N/A
Side roof flashing
Layer 1: Black asphaltic L1: ND N/A
3-tab shingle w/ sand
10527-R-41 Block C Roof, N. Layer 2: Black asphaltic L2: ND N/A
Side vapor barrier
Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Layer 1: Black asphaltic L1: ND N/A
3-tab shingle w/ sand
Layer 2: Black asphaltic L2: ND N/A
10527-R-42 Block C Roof, vapor barrier
Center Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Layer 4: Black asphaltic L4: ND N/A
vapor barrier
ehSin
EHS-International.Inc. 83
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % _ ASBESTOS
Layer 1: Black asphaltic L1: ND N/A
3-tab shingle w/ sand
10527-R-43 Block C Roof, S. Layer 2: Black asphaltic L2: ND N/A
Side vapor barrier
Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Layer 1: White membrane L1: ND N/A
Block B Entrance roofing
10527-R-44 Awning Layer 2: Black asphaltic L2: ND N/A
backing
Layer 3: Brown insulation L3: ND N/A
Layer 1: White membrane L1: ND N/A
Block B Entrance roofing
10527-R-45 Awning Layer 2: Black asphaltic L2: ND N/A
backing
Layer 3: Brown insulation L3: ND N/A
Layer 1: Silver coat L1: 2% Chrysotile
Layer 2: Black asphaltic L2: 4% Chrysotile
built-up roofing
Block C Roof, Layer 3: Black asphaltic
10527-R-46 Flat Roof, S. Side vapor barrier L3: ND N/A
Layer 4: Black asphaltic
vapor barrier L4: ND N/A
Layer 5: Brown paper
vapor barrier L5: ND N/A
Layer 1: Silver coat L1: 2% Chrysotile
Layer 2: Black asphaltic L2: 4% Chrysotile
built-up roofing
Block C Roof, Layer 3: Black asphaltic
10527-R-47 Flat Roof, N. vapor barrier L3: ND N/A
Side Layer 4: Black asphaltic
vapor barrier L4: ND N/A
Layer 5: Brown paper
vapor barrier L5: ND N/A
ehsi. 84
EHS-International,Inc.
• 410
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % , ASBESTOS
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing L3: ND N/A
Layer 3: Brown insulation
Layer 4: Black asphaltic
vapor barrier L4: ND N/A
Roof Over Corridor Layer 5: Black asphaltic L5: ND N/A
10527-R-48 between Block C vapor barrier
and D Layer 6: Yellow foam L6: ND N/A
insulation
Layer 7: Black asphaltic
vapor barrier L7: ND N/A
Layer 8: Black asphaltic L8: ND N/A
vapor barrier
Layer 9: Yellow foam L9: ND N/A
insulation
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing L3: ND N/A
Layer 3: Brown insulation
Layer 4: Black asphaltic L4: ND N/A
vapor barrier
Layer 5: Black asphaltic L5: ND N/A
vapor barrier
10527-R-49 Block D Roof, N. Layer 6: Yellow foam L6: ND N/A
Side insulation
Layer 7: Black asphaltic L7: ND N/A
vapor barrier
Layer 8: Black asphaltic L8: ND N/A
vapor barrier
Layer 9: Yellow foam L9: ND N/A
insulation
Layer 10: White paper L10: ND N/A
vapor barrier
alai 6
EHS-International. 85
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing
Layer 3: Brown insulation L3: ND N/A
Layer 4: Black asphaltic L4: ND N/A
vapor barrier
Layer 5: Black asphaltic L5: ND N/A
vapor barrier
10527-R-50 Block D Roof, S. Layer 6: Yellow foam L6: ND N/A
Side insulation
Layer 7: Black asphaltic L7: ND N/A
vapor barrier
Layer 8: Black asphaltic L8: ND N/A
vapor barrier
Layer 9: Yellow foam L9: ND N/A
insulation
Layer 10: White paper L10: ND N/A
vapor barrier
Layer 1: Silver Coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing
Layer 3: Brown insulation L3: ND N/A
Layer 4: Black asphaltic L4: ND N/A
vapor barrier
Layer 5: Black asphaltic L5: ND N/A
10527-R-51 Block D Roof, E. vapor barrier
Side Layer 6: Yellow foam L6: ND N/A
insulation
Layer 7: Black asphaltic L7: ND N/A
vapor barrier
Layer 8: Black asphaltic L8: ND N/A
vapor barrier
Layer 9: Yellow foam L9: ND N/A
insulation
Layer 1: Black asphaltic L1: ND N/A
3-tab roofing w/ sand
10527-R-52 Block D Roof, E, Layer 2: Black asphaltic L2: ND N/A
Mansard vapor barrier
Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Block D Roof, E. Black asphaltic
10527-R-53 Side penetration sealant on ND N/A
•
roof anchor
e s ►.
86
EHS-International,Inc.
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Block D Roof, N. Black asphaltic sealant
10527-R-54 Side on building wall 4% Chrysotile
flashing
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
10527-R-55 Block E Roof, W. built-up roofing L3: ND N/A
Side Layer 3: Brown insulation
Layer 4: Black asphaltic L4: ND N/A
vapor barrier
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
10527-R-56 Block E Roof, E. built-up roofing L3: ND N/A
Side Layer 3: Brown insulation
Layer 4: Black asphaltic
vapor barrier L4: ND N/A
Layer 1: Black asphaltic L1: ND N/A
built-up roofing w/ sand
Layer 2: Brown insulation L2: ND N/A
Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Layer 4: Black asphaltic L4: ND N/A
Block E Roof, New tar
10527-R-57 Addition, N. Side Layer 5: Yellow foam L5: ND N/A
insulation
Layer 6: Black/gray L6: ND N/A
asphaltic tar
Layer 7: Yellow foam L7: ND N/A
insulation
Layer 8: Black/gray L8: ND N/A
asphaltic tar
Layer 1: Black asphaltic L1: ND N/A
built-up roofing w/ sand
Layer 2: Brown insulation L2: ND N/A
Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Block E Roof, New Layer 4: Black asphaltic L4: ND N/A
10527-R-58 tar
Addition, S. Side
Layer 5: Yellow foam L5: ND N/A
insulation
Layer 6: Black/gray L6: ND N/A
asphaltic tar
Layer 7: Yellow foam L7: ND N/A
insulation
e si4
ENS-Intemational,Inc. 87
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 8: Black/gray L8: ND N/A
asphaltic tar
Block E Roof, New Layer 1: Black asphaltic Li: ND N/A
10527-R-59 Addition, over S. 3-tab roofing w/ sand
Main Entrance Layer 2: Black asphaltic L2: ND N/A
vapor barrier
Block E Roof, New Black asphaltic vapor
10527-R-60 Addition, over S. barrier behind wood siding ND N/A
Main Entrance
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing
10527-R-61 Block F Roof, E. Layer 3: Brown insulation L3: ND N/A
Side Layer 4: Black asphaltic L4: ND N/A
vapor barrier
Layer 5: Black asphaltic L5: ND N/A
tar
Layer 1: Silver coat L1: ND N/A
10527-R-62 Block F Roof, Layer 2: Black asphaltic L2: ND N/A
Center built-up roofing
Layer 3: Brown insulation L3: ND N/A
Layer 1: Silver coat L1: ND N/A
10527-R-63 Block F Roof, W. Layer 2: Black asphaltic L2: ND N/A
Side built-up roofing
Layer 3: Brown insulation L3: ND N/A
Layer 1: Silver coat L1: ND N/A
10527-R-64 Block J Roof, Layer 2: Black asphaltic L2: ND N/A
Center built-up roofing
Layer 3: Brown insulation L3: ND N/A
Layer 1: Silver coat Li: ND N/A
10527-R-65 Block K Roof, Layer 2: Black asphaltic L2: ND N/A
Center built-up roofing
Layer 3: Brown insulation L3: ND N/A
Layer 1: Black asphaltic L1: ND N/A
3-tab roofing w/ sand
Layer 2: Black asphaltic L2: ND N/A
10527-R-66 Block F, S. Side vapor barrier
Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Layer 4: Black asphaltic L4: ND N/A
vapor barrier
ehsi•s
88
EHS-International,Inc.
• !
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Black asphaltic L1: ND N/A
3-tab roofing w/ sand
Layer 2: Black asphaltic L2: ND N/A
10527-R-67 Block J Roof, S. vapor barrier
Side Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Layer 4: Black asphaltic L4: ND N/A
vapor barrier
Layer 1: Black asphaltic L1: ND N/A
3-tab roofing w/ sand
Layer 2: Black asphaltic L2: ND N/A
10527-R-68 Block K Roof, S. vapor barrier
Side Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Layer 4: Black asphaltic L4: ND N/A
vapor barrier
Layer 1: Silver Coat L1: ND N/A
Block F Roof Layer 2: Black asphaltic L2: ND N/A
10527-R-69 Center (Roof Curb) built-up roofing
Layer 3: Black asphaltic L3: ND N/A
vapor barrier
10527-R-70 Block F Roof, Gray/silver caulking ND N/A
Central Area around roof vent
10527-R-71 Block F Roof, Gray seam caulking w/ ND N/A
Central Area paint
Layer 1: Silver coat L1: ND N/A
Block G Roof, W. Layer 2: Black asphaltic L2: ND N/A
10527-R-72 Side built-up roofing
Layer 3: Brown insulation L3: ND N/A
Layer 1: Silver coat L1: ND N/A
Block G Roof, E. Layer 2: Black asphaltic L2: ND N/A
10527-R-73 Side built-up roofing
Layer 3: Brown insulation L3: ND N/A
10527-R-74 Block G Roof, E. Black penetration sealant ND N/A
Side on lead vent pipe
Layer 1: Black asphaltic L1: ND N/A
3-tab roofing w/ sand
Layer 2: Black asphaltic L2: ND N/A
10527-R-75 Block H Roof, vapor barrier
Covered Walkway Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Layer 4: Black asphaltic L4: ND N/A
vapor barrier
ehsi
ENS-International.Inc. 89
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATIERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Black asphaltic L1: ND N/A
3-tab roofing w/ sand
Layer 2: Black asphaltic L2: ND N/A
10527-R-76 Block H Roof, W. vapor barrier
Side Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Layer 4: Black asphaltic L4: ND N/A
vapor barrier
Layer 1: Silver Coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing
Layer 3: Brown insulation L3: ND N/A
Layer 4: Black asphaltic L4: ND N/A
vapor barrier
10527-R-77 Block L Roof, E. Layer 5: Yellow foam L5: ND N/A
Low Roof insulation
Layer 6: Black asphaltic L6: ND N/A
vapor barrier
Layer 7: Yellow foam L7: ND N/A
insulation
Layer 8: White paper L8: ND N/A
vapor barrier
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing
Layer 3: Brown insulation L3: ND N/A
Layer 4: Black asphaltic L4: ND N/A
vapor barrier
10527-R-78 Block L Roof, S. Layer 5: Yellow foam L5: ND N/A
High Roof insulation
Layer 6: Black asphaltic L6: ND N/A
vapor barrier
Layer 7: Yellow foam L7: ND N/A
insulation
Layer 8: White paper L8: ND N/A
vapor barrier
ehs .' 90
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing
Layer 3: Brown insulation L3: ND N/A
Layer 4: Black asphaltic L4: ND N/A
vapor barrier
10527-R-79 Block L Roof, N. Layer 5: Yellow foam L5: ND N/A
High Roof insulation
Layer 6: Black asphaltic L6: ND N/A
vapor barrier
Layer 7: Yellow foam L7: ND N/A
insulation
Layer 8: White paper L8: ND N/A
vapor barrier
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing
Layer 3: Brown insulation L3: ND N/A
Layer 4: Black asphaltic L4: ND N/A
10527-R-80 Block M Roof, N. vapor barrier
High Roof Layer 5: Yellow foam L5: ND N/A
insulation
Layer 6: Black asphaltic L6: ND N/A
vapor barrier
Layer 7: Yellow foam L7: ND N/A
insulation
Layer 1: Silver coat L1: ND N/A
Layer 2: Black asphaltic L2: ND N/A
built-up roofing
Layer 3: Brown insulation L3: ND N/A
Layer 4: Black asphaltic L4: ND N/A
10527-R-81 Block M Roof, E. vapor barrier
Low Roof Layer 5: Yellow foam L5: ND N/A
insulation
Layer 6: Black asphaltic L6: ND N/A
vapor barrier
Layer 7: Yellow foam L7: ND N/A
insulation
10527-R-82 Block M Roof, E. White/gray flex duct ND N/A
Low Roof (2'X3')
10527-R-83 Block M Roof, E. White flex duct (8" round) ND N/A
Low Roof
Block M Roof, E. Black asphaltic
10527-R-84 Low Roof penetration sealant on 4% Chrysotile
lead vent pipe
ehsi
ENS-International,Inc. 91
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Covered Walkway Layer 1: Black asphaltic L1: ND N/A
10527-R-85 Roof between 3-tab roofing w/ sand
Block A and C Layer 2: Black asphaltic L2: ND N/A
vapor barrier
Layer 1: Black asphaltic L1: 4% Chrysotile
tar
Layer 2: Black asphaltic L2: ND N/A
10527-R-86 Block N (P1) built-up roofing
Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Layer 4: Brown paper L4: ND N/A
vapor barrier (on wood)
Layer 1: Black asphaltic L1: 4% Chrysotile
tar
Layer 2: Black asphaltic L2: ND N/A
10527-R-87 Block N (P1), built-up roofing
East Side Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Layer 4: Brown paper L4: ND N/A
vapor barrier (on wood)
Layer 1: Black asphaltic L1: 4% Chrysotile
Block N (P1), roof' patch
0527-R-88 Layer 2: Trace silver coat L2: ND N/A
East Side Layer 3: Black asphaltic L3: ND N/A
built-up roofing on wood
Block N (P1), East Black asphaltic
10527-R-89 Side penetration sealant on ND N/A
conduit
Layer 1: Silver coat L1: 2% Chrysotile
Layer 2: Black asphaltic L2: ND N/A
Block M, West
built-up roofing
10527-R-90 Entryway Layer 3: Black asphaltic L3: ND N/A
vapor barrier
Layer 4: Black asphaltic L4: ND N/A
tar on concrete
Layer 1: Trace Silver Coat L1: ND N/A
Block M, West Layer 2: Black asphaltic L2: 4% Chrysotile
10527-R-91 tar
Entryway Layer 3: Black asphaltic
built-up roofing w/ tar L3: ND N/A
10527-R-92 P2 Roof Black asphaltic 3-tab ND N/A
roof nic
10527-R-93 P2 Roof Black asphaltic 3-tab ND N/A
roofing
ehsi�. 92
EHS-International,Inc.
• t
Limited Hazardous Materials Survey Report
Federal Way High School
• EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Trace beige L1: ND N/A
Central Covered coating
10527-R-94 Walkway, N. Layer 2: Black asphaltic L2: 18% Chrysotile
Side fibrous coating
Layer 1: Trace beige L1: ND N/A
10527-R-95 Central Covered coating w/white paint L2: 21% Chrysotile
Walkway, Center Layer 2: Black asphaltic
fibrous coating
Layer 1: Trace beige
L1: ND N/A
10527-R-96 Central Covered coating L2: 17% Chrysotile
Walkway, S. Side Layer 2: Black asphaltic
fibrous coating
Layer 1: Trace beige L1: ND N/A
10527-R-97 S. Entrance to coating L2: 20% Chrysotile
Block A Layer 2: Black asphaltic
fibrous coating
Layer 1: Trace beige L1: ND N/A
10527-R-98
W. Entrance to coating L2: 21% Chrysotile
Block C Layer 2: Black asphaltic
fibrous coating
PORTABLE 1 (P1)
Layer 1: 12"x12" Light L1: ND N/A
yellow VCT w/ white
10527-P1-01 Portable 1, streaks
Northwest Corner Layer 2: Yellow and black L2:ND N/A
mastic
Layer 3: Wood subfloor L3: ND N/A
Layer 1: 4"Tan cove base L1: ND N/A
Layer 2: Cream colored
10527-P1-02 Portable 1, mastic L2: ND N/A
Northeast Corner Layer 3: Remnant Brown
L3: ND N/A
mastic
Layer 1: Beige wall L1: ND N/A
covering w/paint
10527-P1- Portable 1, NW Layer 2: White wall L2: 52% Chrysotile
03 Corner cover backing
Layer 3: JC w/ paper L3: ND N/A
Layer 4: GWB w/ paper L4: ND N/A
(corner)
ehsi
ENS-International.Inc. 93
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: Beige wall L1: ND N/A
10527-P1- Portable 1, West covering
04 Wall Layer 2: White wall L2: 51% Chrysotile
cover backing
Layer 3: GWB (mid wall) L3: ND N/A
Layer 1: Beige w/ green L1: ND N/A
wall covering
10527-P1- Portable 1, East Layer 2: White wall L2: 52% Chrysotile
05*7 Wall cover backing
Layer 3: JC w/ paper L3: 0.5% Chrysotile
Layer 4: GWB (mid wall) L4: ND N/A
10527-P1Portable 1, Ceiling, Layer 1: JC w/paint L1: 0.75% Chrysotile
06*7 East Layer 2: GWB (ceiling L2: ND N/A
_ edge)
10527-P1-07 Portable 1, Ceiling, GWB w/ paper and paint ND N/A
_East (mid ceiling)
Layer 1: 1'x1' White ACT L1: ND N/A
w/ pin hole pattern
10527-P1- Portable 1, Ceiling, Layer 2: Dark brown glue L2: ND N/A
08QA Southeast dot
Layer 3: 1'x1 ACT debris L3: ND N/A
Layer 4: Brown glue dot L4: ND N/A
10527-P1-09 Portable 1, North Gray window glazing putty ND N/A
Wall
Layer 1:Remnant chalk L1: ND N/A
10527-P1-10 Portable 1, West board backing
Wall Layer 2: Cork board L2: ND N/A
Layer 2: Brown mastic L3: ND N/A
Portable 1, Layer 1: Beige paint
10527-P1-11 Exterior, North Layer 2: Black asphaltic ND N/A
Wall vapor barrier
Portable 1, Layer 1: Gray window L1: 3% Chrysotile
10527-P1- glazing putty
Exterior, North
12 Wall Layer 2: Trace yellow L2: ND N/A
mastic
Portable 1, Layer 1: Black asphaltic L1: ND N/A
10527-P1-13 vapor barrier
Exterior, East Wall
Layer 2: GWB w/. paper L2: ND N/A
PORTABLE 2 (P2)
Layer 1: Blue multi- L1: ND N/A
10527-P2-01 Portable 2, colored carpet
Conference Layer 2: Clear mastic L2: ND N/A
Layer 3: Wood sub-floor L3: ND N/A
et/Si94
EHS-International,Inc.
•
Limited Hazardous Materials Survey Report
Federal Way High School
• EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: 4" Blue cove L1: ND N/A
10527-P2-02 Portable base
2,Conference Layer 2: Cream colored L2: ND N/A
mastic
10527-P2-03 Portable 2, 2'X4' SACT w/ worm track ND N/A
Classroom pattern
Layer 1: Beige wall L1: ND N/A
Portable 2, covering L2: ND N/A
10527-P2-04 Classroom Layer 2: Brown fiberboard
Layer 3: JC w/ paint L3: ND N/A
Layer 4: GWB w/ paper L4: ND N/A
Layer 1: Beige wall L1: ND N/A
Portable 2, covering w/paint L2: ND N/A
10527-P2-05Layer 2: Brown fiberboard
Conference
Layer 3: JC w/ paint L3: ND N/A
Layer 4: GWB w/ paper L4: ND N/A
L1: ND N/A
Layer 1: Beige wall
10527-P2-06 Portable 2, Office covering w/paint L2: ND N/A
Layer 2: Brown fiberboard
Layer 3: GWB w/ paper L3: ND N/A
L4: ND N/A
COMMUNITY POOL
Layer 1: Dark blue rubber L1: ND N/A
flooring
10527-CP- Layer 2: White/beige L2: ND N/A
01 Office mastic
Layer 3: Tan VAT L3: 2% Chrysotile
Layer 4: Black mastic L4: 3% Chrysotile
on concrete
Layer 1: Dark blue Rubber L1: ND N/A
flooring
10527-CP- Layer 2: White/beige L2: ND N/A
02 Lobby mastic
Layer 3: Tan VAT L3: 2% Chrysotile
Layer 4: Black mastic L4: 3% Chrysotile
on concrete
Layer 1: 4" Blue cove L1: ND N/A
10527-CP-03 Central Corridor base L2: ND N/A
Layer 2: Beige/brown
mastic
eSI�►�
ENS-International,Inc. 95
•
. F
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Layer 1: 12"x 12" Sea L1: ND N/A
Staff Men green VCT
10527-CP-04 Layer 2: Yellow mastic L2: ND N/A
Restroom Layer 3: Trace black L3: ND N/A
mastic w/ concrete dust
Layer 1: 4" Black cove L1: ND N/A
10527-CP- Staff Men base
05QA Restroom Layer 2: Beige/brown L2: ND N/A
mastic
Layer 1: 1"x1" Blue L1: ND N/A
ceramic floor tile
10527-CP-06 Men Locker Room L2: ND N/A
Layer 2: Gray grout
Layer 3: Dark gray mortar L3: ND N/A
Layer 1: 4" Off-white L1: ND N/A
10527-CP-07 Men Locker Room ceramic wall tile
Layer 2: White grout L2: ND N/A
Layer 3: Dark gray mortar L3: ND N/A
10527-CP-08 Pool Area Layer 1: Red brick L1: ND N/A
Layer 2: Gray grout L2: ND N/A
Layer 1: JC w/ paint and L1: ND N/A
10527-CP-09 Men Locker Room paper
Layer 2: GWB w/ paint L2: ND N/A
and paper (ceiling edge)
10527-CP-10 Men Locker Room Layer 1: GWB w/ paint ND N/A
(mid ceiling)
10527-CP- Layer 1: JC w/ paint L1: 0.5% Chrysotile
11`$ Lobby Layer 2: Brown GWB w/ L2: ND N/A
paper (ceiling edge)
10527-CP-12 Lobby Brown GWB w/ paint (mid ND N/A
ceiIiri )
10527-CP- Layer 1: JC w/ paint L1: 0.5% Chrysotile
13*8 Lobby Layer 2: Brown GWB w/ L2: ND N/A
paper (mid ceiling)
10527-CP- Women Locker JC/Brown GWB w/ paint 0.5% Chrysotile
14*8 Room (ceiling edge)
10527-CP-15 Women Locker Brown GWB w/ paint and ND N/A
Room paper (mid ceiling)
10527-CP- Layer 1: JC w/ paint L1: 0.25% Chrysotile
16'$ Storage Room Layer 2: Brown GWB w/ L2: ND N/A
paper (corner wall)
Layer 1: JC w/ paint L1: ND N/A
10527-CP-17 Storage Room Layer 2: Brown GWB w/ L2: ND N/A
paper (mid wall)
ehsI..b
ENS-International.Inc. 96
•
•
Limited Hazardous Materials Survey Report
Federal Way High School
• EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
10527-CP- Layer 1: JC w/ paint L1: 0.5% Chrysotile
18'$ Office Layer 2: Brown GWB w/ L2: ND N/A
paper ( corner wall)
10527-CP-19 Office Brown GWB w/ paint and ND N/A
paper (mid wall)
10527-CP-20 Staff Women Brown GWB w/ paint and ND N/A
Restroom paper (mid wall)
Staff Women Layer 1: Fiber reinforced L1: ND N/A
10527-CP-21 Restroom wall panel
Layer 2: Clear mastic L2: ND N/A
Gray caulking (between
10527-CP-22 Pool Area pool edge ceramic flooring ND N/A
and concrete walkway)
Dark brown/black interior
window frame caulking
10527-CP-23 Pool Area (on 1'x8' metal framed ND N/A
windows)
10527-CP-24 Pool Area Brown door frame ND N/A
caulking
10527-CP-25 Pool Area White/beige caulking on ND N/A
brick wall
10527-CP- White cloth flex duct
26 Boiler Room (4'x4') 60% Chrysotile
10527-CP-27 Boiler Room Black flex duct (2'x2') ND N/A
10527-CP-28 Boiler Room Silver paint on metal duct ND N/A
Layer 1: Red seam L1: 2% Chrysotile
10527-CP- sealant w/ paint
29 Boiler Room Layer 2: Black asphaltic L2: 6% Chrysotile
seam sealant w/mastic
on AHU
10527-CP- Boiler Room Silver paint of boiler 2% Chrysotile
30 exterior
Layer 1: Cloth L1: ND N/A
10527-CP- insulation wrap
31 Boiler Room Layer 2: MAG insulation L2: 6% Chrysotile
on boiler exhaust duct 4% Amosite
Layer 1: Cloth L1: ND N/A
10527-CP- insulation wrap
32 Boiler Room Layer 2: MAG insulation L2: 5% Chrysotile
on boiler exhaust duct 4% Amosite
Layer 1: Cloth L1: ND N/A
10527-CP- insulation wrap
33 Boiler Room Layer 2: MAG insulation L2: 6% Chrysotile
on boiler exhaust duct 4% Amosite
ehsI.)
EHS-International,Inc. 97
• S
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
10527-CP-34 Pool, West Wall White hard pool lining ND N/A
material
10527-CP-35 Pool West, Floor White hard pool lining ND N/A
material
10527-CP-36 Pool Center, Floor White hard pool lining ND N/A
material
10527-CP-37 Pool, East Wall White hard pool lining ND N/A
material
10527-CP- Pool Floor, East White hard pool lining ND N/A
38QA material
Layer 1: 1"x 1"Tan L1: ND N/A
ceramic floor tile L2: ND N/A
10527-CP-39 Women's Locker Layer 2: Gray/beige grout
Room Layer 3: Trace white L3: ND N/A
mastic
Layer 4: Gray mortar L4: ND N/A
Layer 1: 6"Tan ceramic L1: ND N/A
10527-CP-40 Pool Area cove base
Layer 2: Gray/beige grout L2: ND N/A
Layer 1: White cloth L1: ND N/A
10527-CP- Layer 2: Brown fiber L2: ND N/A
41 Office board
Layer 3: Brown/black L3: 3% Chrysotile
mastic
Men's Locker
10527-CP- White cloth flex duct 58% Chrysotile
42 Room, Attic (3'x3')
Space
Men's Locker Layer 1: White cloth L1: ND N/A
10527-CP- Room Attic insulation wrap
43 Space Layer 2: TSI on small L2: 3% Amosite
bore pipe elbow
Men's Locker Layer 1: White cloth L1: ND N/A
10527-CP- Room Attic insulation wrap
44 Space Layer 2: TSI on small L2: 3% Amosite
bore pipe elbow
Men's Locker
10527-CP- TSI on small bore pipe °
45 Room, Attic elbow 3% Amosite
Space
Layer 1: 12"x 12" Beige L1: ND N/A
10527-CP-46 Boiler Room VCT w/paint
Closet/Office Layer 2: Yellow/clear L2: ND N/A
mastic
&mi.)
98
EHS-International Inc.
•
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF
NUMBER LOCATION DESCRIPTION % ASBESTOS
Exterior West Black/brown paper
10527-CP-47 Side (between metal siding and ND N/A
brick wall)
Exterior, West Black hard material
10527-CP-48 Side (between foundation wall ND N/A
and brick wall)
10527-CP-49 Exterior, West Beige/gray door frame ND N/A
Side caulking
10527-CP-50 Exterior, East Side Gray caulking (on metal ND N/A
jacketed fiberglass runs)
10527-CP-51 Storage Room Cork board w/ tan/brown ND N/A
mastic
10527 CP Lobby Reception Layer 1: Blue formica Li: ND N/A
52QA Area countertop
Layer 2: Tan/red mastic L2: ND N/A
EFIS= Exterior Finish Insulation System
" When QA lab and primary lab sample results differed, EHSI reported the most restrictive
(e.g., highest % asbestos) in Table 1. Analytical results for all analyses are provided in
Appendix A.
* Point counted samples
1 Preliminary analytical reports indicated that the plaster ceiling system in the 1952 Era Multi-
Purpose Building (Block A) in the Federal Way High School contains approximately 2%
Chrysotile asbestos. This ACM plaster ceiling system constitutes a surfacing material as
defined by the AHERA regulation. EHSI re-submitted the plaster samples reported to have
greater than 1% asbestos concentration for re-analysis using the more precise EPA "Point
Count" method. The "Point Count" analytical method is recommended by the EPA for samples
with less than 10% asbestos. Based on the results of that re-analysis, the skim coating on
plaster ceiling was determined to be a non-ACM (e.g., containing < 1% asbestos fibers) and
are therefore not ACM "surfacing materials". Only the "Point Count" re-analysis concentrations
are listed in Table 1. Analytical results for all analyses are provided in Appendix A.
2 Preliminary analytical reports indicated that the joint compound (JC) "skim coating" on the
GWB wall system in the Original 1937 Era Building (Block C) in the Federal Way High School
contains approximately 2% Chrysotile asbestos. This ACM JC/GWB system constitutes a
surfacing material as defined by the AHERA regulation. EHSI re-submitted the plaster samples
reported to have greater than 1% asbestos concentration for re-analysis using the more
precise EPA "Point Count" method. The "Point Count" analytical method is recommended by
the EPA for samples with less than 10% asbestos. Based on the results of that re-analysis,
the JC "skim coating" on GWB walls was determined to be a non-ACM (e.g., containing < 1%
asbestos fibers) and are therefore not ACM "surfacing materials". Only the "Point Count" re-
e s
99
EHS-International.Inc.
• S .
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
analysis concentrations are listed in Table 1. Analytical results for all analyses are provided in
Appendix A.
3 Preliminary analytical reports indicated that the JC "skim coating" on the GWB and plaster
wall systems in the 1954 Era Library and Classroom Building (Block D) in the Federal Way
High School contains approximately 2% Chrysotile asbestos. This ACM JC/GWB/plaster ceiling
system constitutes a surfacing material as defined by the AHERA regulation. EHSI re-
submitted the plaster samples reported to have greater than 1% asbestos concentration for
re-analysis using the more precise EPA "Point Count" method. The "Point Count" analytical
method is recommended by the EPA for samples with less than 10% asbestos. Based on the
results of that re-analysis, the JC "skim coating" on GWB and plaster wall/ceiling system was
determined to be a non-ACM (e.g., containing < 1% asbestos fibers) and are therefore not
ACM "surfacing materials". Only the "Point Count" re-analysis concentrations are listed in
Table 1. Analytical results for all analyses are provided in Appendix A.
4 Preliminary analytical reports indicated that the gray mortar under the ceramic tile window
sill in the 1962 Era Classroom Building (Block J)in the Federal Way High School contains <1%
Chrysotile asbestos. EHSI re-submitted the mortar samples reported to have greater than
<1% asbestos concentration for re-analysis using the more precise EPA "Point Count"
method. The "Point Count" analytical method is recommended by the EPA for samples with
less than 10% asbestos. Based on the results of that re-analysis, the mortar sample was
determined to be a non-ACM (e.g., containing < 1% asbestos fibers) and are therefore not
ACM. Only the "Point Count" re-analysis concentrations are listed in Table 1. Analytical results
for all analyses are provided in Appendix A.
5 Preliminary analytical reports indicated that the JC "skim coating" on the GWB wall system
in the 1957 Era Building (Block L) in the Federal Way High School contains approximately 2%
Chrysotile asbestos. This ACM GWB system constitutes a surfacing material as defined by the
AHERA regulation. EHSI re-submitted the JC/GWB samples reported to have greater than 1%
asbestos concentration for re-analysis using the more precise EPA "Point Count" method. The
"Point Count" analytical method is recommended by the EPA for samples with less than 10%
asbestos. Based on the results of that re-analysis, the JC "skim coating" on GWB walls was
determined to be a non-ACM (e.g., containing < 1% asbestos fibers) and are therefore not
ACM "surfacing materials". Only the "Point Count" re-analysis concentrations are listed in
Table 1. Analytical results for all analyses are provided in Appendix A.
6 Preliminary analytical reports indicated that the JC "skim coating" on the GWB and plaster
wall and ceiling system in the 1957 Era Building (Block M) in the Federal Way High School
contains approximately 2% Chrysotile asbestos. This ACM "skim coating" on the GWB/plaster
wall/ceiling system constitutes a surfacing material as defined by the AHERA regulation. EHSI
re-submitted the plaster samples reported to have greater than 1% asbestos concentration
for re-analysis using the more precise EPA"Point Count" method. The "Point Count"analytical
method is recommended by the EPA for samples with less than 10% asbestos. Based on the
results of that re-analysis, the JC "skim coating" on GWB and plaster wall/ceiling system was
determined to be a non-ACM (e.g., containing < 1% asbestos fibers) and are therefore not
ACM "surfacing materials". Only the "Point Count" re-analysis concentrations are listed in
Table 1. Analytical results for all analyses are provided in Appendix A.
Preliminary analytical reports indicated that the GWB wall and ceiling system in Portable 1
Building on the Federal Way High School Campus contains approximately 2% and 3%
Chrysotile asbestos. This ACM GWB system constitutes a surfacing material as defined by the
ehs/ ,
ENS-International,Inc.
•
Limited Hazardous Materials Survey Report
Federal Way High School
• EHSI Project 10527
July 12, 2013
AHERA regulation. EHSI re-submitted the GWB samples reported to have greater than 1%
asbestos concentration for re-analysis using the more precise EPA "Point Count" method. The
"Point Count" analytical method is recommended by the EPA for samples with less than 10%
asbestos. Based on the results of that re-analysis, the skim coating on GWB walls was
determined to be a non-ACM (e.g., containing < 1% asbestos fibers) and are therefore not
ACM "surfacing materials". Only the "Point Count" re-analysis concentrations are listed in
Table 1. Analytical results for all analyses are provided in Appendix A.
8 Preliminary analytical reports indicated that the JC "skim coating" on the GWB wall and
ceiling system in the Community Pool Building on the Federal Way High School Campus
contains approximately 2% to 3% Chrysotile asbestos. This ACM JC "skim coating" on the
GWB wall system constitutes a surfacing material as defined by the AHERA regulation. EHSI
re-submitted the GWB samples reported to have greater than 1% asbestos concentration for
re-analysis using the more precise EPA "Point Count" method. The "Point Count" analytical
method is recommended by the EPA for samples with less than 10% asbestos. Based on the
results of that re-analysis, the JC "skim coating" on GWB walls was determined to be a non-
ACM (e.g., containing < 1% asbestos fibers) and are therefore not ACM "surfacing materials".
Only the "Point Count" re-analysis concentrations are listed in Table 1. Analytical results for all
analyses are provided in Appendix A.
Washington State Department of Labor and Industries (L&I) requires special worker
exposure precautions and qualifications when dealing with ACM used on seams and nail
holes (refer to L&I regulations and WISHA Regional Directives {WRD}), Similar
requirements exist for walls and ceilings skim-coated with material that contains less than
one percent (<1%) asbestos fibers. Any "dust creating activity", such as: sanding, sawing,
grinding, or drilling of GWB walls or ceilings shall be accomplished by certified asbestos
workers using glove-bag, mini-enclosure and/or negative pressure enclosure engineering
controls and work practices. As directed by WRD 23.30, for all other demolition or
disturbance of GWB walls/ceilings with ACM JC or of walls/ceilings skim coated with <1%
asbestos, employees shall have received at least two hours of asbestos awareness training
as specified L&I instruction 296-62-07722(5).
Table 2 summarizes materials identified by EHSI as containing greater than 1% asbestos
fibers during its survey, and un-sampled materials assumed to be ACM. The Table 2
Summary of Asbestos Containing Materials is for engineering cost estimating
purposes and is not intended for bid quantifications.
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL QUANTITY
DESCRIPTION LOCATION EXPECTED TO BE
IMPACTED
Block A
Multiple layers of ACM black asphaltic
built up roofing with ACM tar on non- Interstitial Space above
6,550 SF
ACM brown fibrous insulation on ACM Boy's Locker Room '
black asphaltic vapor barrier on wood
ehsi
EHS-Intemational,Inc. 10
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527 `
July 12, 2013
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL QUANTITY
DESCRIPTION LOCATION EXPECTED TO BE
IMPACTED
Non-ACM 12"x12" VCT w/ non-ACM
yellow mastic on non-ACM gray Gym Corridor 9,250 SF
leveling compound on ACM black
mastic on concrete
ACM brown stair tread on non-ACM 2nd Floor Stairwell 1 and
green, brown, and yellow mastic on 2 500 SF
wood
ACM brown SVF stair landing on non- 2nd Floor Stairwell 1 and 250 SF
ACM yellow mastic on wood 2
ACM 8" stair stringer w/ non-ACM 2nd Floor Stairwell 1 and 325 LF
brown mastic 2
Carpet w/ non-ACM yellow carpet
mastic on 9"x9" burnt orange VAT w/ Marketing A75 1,000 SF
non-ACM black mastic on concrete
Carpet w/ non-ACM yellow carpet
mastic on non-ACM gray leveling Marketing A75 Storage 250 SF
compound on 9"x9" burnt orange VAT A76 and A77
w/ non-ACM black mastic on concrete
Blue carpet w/ non-ACM yellow carpet
mastic on non-ACM gray leveling ASB A5 500 SF
compound on ACM residual black
mastic on concrete
Hard wood floor w/ non-ACM brown
paper vapor barrier w/ non-ACM black
asphaltic backing on hardwood floor Main Gymnasium 12,000 SF
sleepers on ACM multi-layered black
asphaltic vapor barrier beneath tarred
to concrete
Lockers A10, Lockers
A24, Exercise A33,
Assumed ACM white board mastic Training A38, Lockers 10 EA
A50/A60, and marketing
A75
Assumed ACM tack board mastic Marketing A75 5 EA
Assumed ACM cabinet mastic Weights A39 25 SF
Boy's and Girl's Locker
Assumed ACM mirror mastic Rooms, Weight Room 15 EA
A39, and Restroom
Assumed ACM electrical panel backing Mechanical Room 10 EA
Assumed ACM fire doors Throughout 65 EA
Assumed ACM TSI on small bore pipe
runs and fitting (concealed in plumbing Throughout 750 LF
walls and ceilings)
Block B
ehsi ,o
EHS-International,Inc.
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL •
ASBESTOS MATERIAL QUANTITY
DESCRIPTION LOCATION EXPECTED TO BE
IMPACTED
Non-ACM 12"x12" blue VCT w/ non-
ACM yellow mastic on ACM residual Cafeteria B1/B2 6,000 SF
black mastic on concrete
ACM Gray window glazing putty on Corridor B5 3 EA
4'x5' windows
Non ACM 4"tan/gray CB w/ non ACM
creme colored mastic on ACM residual Corridor B5 450 LF
brown mastic on concrete
ACM Gray window glazing putty on Cafeteria B2 9 EA
4'x3' clearstory windows
Assumed ACM mirror mastic Kitchen Restroom, 2 EA
Kitchen 5-9
Assumed ACM white board mastic Throughout 2 EA
Assumed ACM fire doors Throughout 12 EA
Assumed ACM TSI on small bore pipe
runs and fitting (concealed in plumbing Throughout 750 LF
walls and ceilings)
Block C
ACM black sink undercoat Faculty Lounge 1 EA
Non-ACM 12"x12" blue VCT w/ non-
ACM yellow mastic on non-ACM gray Original Building 2, OOOSF
leveling compound on ACM residual Corridor C 116
black mastic on concrete
Non-ACM 12"x12" light gray VCT w/
non-ACM yellow/tan mastic on non Original Building
ACM gray leveling compound on 9"x9" Corridor C 116 200 SF
black VAT w/ ACM black mastic on
concrete
Non-ACM 12"x12" off-white VCT (w/
brown, yellow, and white streaks) w/ Original Building
non-ACM yellow mastic on non-ACM passage C 115 250 SF
gray leveling compound on ACM
residual black mastic on concrete
Carpet w/ non-ACM beige and yellow
carpet mastic on 12"x12" off-white
non-ACM VCT (w/ brown, yellow, and Original Building
white streaks) w/ non-ACM yellow Copy C 111, Data 525 SF
mastic on non-ACM gray leveling Processing, Conference
compound on ACM residual black C 108
mastic on concrete
ehsi �o
EH�Intemational,Inc.
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL QUANTITY
DESCRIPTION LOCATION EXPECTED TO BE
IMPACTED
Non-ACM light gray SVF (w/ broken
rock pattern) w/ non-ACM brown paper
backing w/ non-ACM mastic on non- Janitor C-110 100 SF
ACM gray/brown leveling compound on
ACM residual black mastic on concrete
Blue carpet w/ non-ACM yellow/brown
mastic on non-ACM gray leveling Original Building C-107 775 SF
compound on ACM residual black
mastic on concrete
Carpet w/non-ACM yellow/tan mastic
on non-ACM gray leveling compound Original Building Girls C- 325 SF
on 9"x9" black VAT w/ ACM black 135
mastic on concrete
Non-ACM orange SVF (with yellow and Original Building 2nd
brown streaks) with non-ACM yellow Floor Janitor Closet C- 100 SF
mastic w/ ACM gray paper backing on 217
ACM residual black mastic on concrete
Non-ACM light gray SVF (w/ broken
rock pattern) with non-ACM beige Original Building 2nd
paper backing and non-ACM beige 500 SF
mastic w/ 9"x9" black VAT w/ ACM Floor Storage C-218
black mastic on concrete
Non-ACM 12"x12" off-white VCT (w/
brown, yellow, and white streaks) with
non-ACM yellow mastic on non-ACM Original Building 2nd 1,400 SF
gray leveling compound on 9"x9" black Floor Corridor C-216
VAT w/ ACM black mastic on wood
Carpet with non-ACM yellow mastic on Original Building 2nd
9"x9" dark red VAT w/ ACM black Floor E. Classroom C- 645 SF
mastic on wood 206
Carpet with non-ACM yellow/brown
mastic on ACM residual black mastic on Original Building 2"d
non-ACM fiberboard with non-ACM Floor E. Classroom C- 400 SF
clear coat on hard wood floor on non- 206
ACM black vapor barrier
ACM NicoliteTM in wood fire wall Original Building Attic 300 SF
ACM Black asphaltic sealant at vent Original Building Attic 50 EA
penetration
ACM MAG TSI pipe run (<6" OD) in Original Building 2nd
wall Floor Room 45 LF
Replacement of Stairs
ehsie)
EHS-International,Inc. 10
s •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL QUANTITY
DESCRIPTION LOCATION EXPECTED TO BE
IMPACTED
Carpet with non-ACM yellow mastic on Building Addition 2nd
9"x9" gray VAT w/ ACM black mastic Floor E. Classroom C 3,075 SF
on wood 211, C-212, C-213, C-
215, and Corridor C-214
Non-ACM 12"x12" off-white VCT (w/
brown, yellow and white streaks) w/ Building Addition 1St
non-ACM yellow mastic on non-ACM Floor Nurse C-126 and 325 SF
gray leveling compound on ACM Office C-128
residual black mastic on concrete
Carpet w/ non-ACM yellow mastic on Building Addition 1St
9"x9" off-white and gray VAT w/ ACM Floor Vice Principal C- 675 SF
black mastic on concrete 125 and Clerical C-122
Carpet w/ non-ACM yellow carpet
mastic on non-ACM gray leveling Waiting C-129 145 SF
compound on ACM residual black
mastic on concrete
2nd Floor Original
Building E. Classroom C-
201-208, Stairwell
replacement classroom,
Listening C-210 1st Floor
Assumed ACM white board mastic Building Addition, V.P. 50 EA
123, 124, 125, Principal
C-120, Conference C-
119, 2nd Floor Building
Addition Computers C-
212, E. Classroom C-
211,213 and C-205
2nd floor Original
Assumed ACM tack board mastic Building E. Classroom C- 5 EA
206
ehS/..�
ENS-international,Inc. 10
• S
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL QUANTITY
DESCRIPTION LOCATION EXPECTED TO BE
IMPACTED
1st Floor Building
Addition 1st Floor
Building Addition, V.P.
123, 124, 125, Principal
C-120, Conference C-
119, Waiting C-129, ATI
C132, BKPR C-131,
Assumed ACM mastic associated with Work C-130, Wait C- 1,000 SF
wood wall paneling 121, 2nd Floor Original
Building E. Classroom C-
201-208, Stairwell
replacement classroom,
2nd Floor Building
Addition Computers C-
212, E. Classroom C-
211,213 and C-205
2nd Floor Original
Building E. Classroom C-
201-C-208
Assumed ACM cabinet mastic 2nd Floor Building 120 SF
Addition Computers C-
212, E. Classroom C-
211,213 and C-205
Assumed ACM locker mastic 2nd Floor Original 200 SF
Building Corridor C-216
1st Floor Original
Assumed ACM mirror mastic Building Girls C 135, 6 EA
and 2nd Floor Original
Building C-220
Assumed ACM electrical panels and 1st Floor Boiler Room 10 EA
components and 2nd Floor C-127
Assumed ACM fire doors Throughout 20 EA
Assumed ACM TSI on small bore pipe
runs and fitting (concealed in plumbing Throughout 750 LF
walls and ceilings)
Block D
Library D-15,
Blue carpet with non-ACM yellow/tan Conference D-16 Audio
mastic on ACM residual black mastic on Video Classroom D 17, 2,500 SF
concrete Alcove D-18, Work
Room D-19 and
Magazine D-20 1
White NicloliteTM paper in wood fire Library Attic 500 SF
wall
ehs1-4.0
10
EHS-International,Inc.
• I
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL QUANTITY
DESCRIPTION LOCATION EXPECTED TO BE
IMPACTED
Non-ACM silver paint on ACM black Library Attic 5 SF
asphaltic tar/sealant
Carpet w/ non-ACM gray foam carpet
backing w/ non-ACM clear mastic on
non-ACM 12"x12" off-white VCT (w/ Corridor D-14 1,750 SF
brown, yellow, and white streaks) w/
non-ACM yellow mastic on ACM
residual black mastic on concrete
Carpet with non-ACM brown and
orange mastic on 9"x9" tan VAT (w/ Corridor D-14 1,750 SF
white and brown streaks) w/ ACM
black mastic on concrete
Carpet w/ non-ACM gray foam carpet
backing w/ non-ACM clear/yellow Corridor D-13 375 SF
mastic on ACM residual black mastic on
concrete
ACM black sink undercoat Office D-11 1 EA
A.V. Classroom D-17,
Assumed ACM white board mastic Conference D-16, S.S. 40 EA
Classrooms D-1-D-8
Assumed ACM tack board mastic Library D-15, 1 EA
Library D-15, A.V.
Assumed ACM mastic associated with Classroom D-17, 1,000 SF
wood wall paneling Corridor D-14 and
Classrooms D-1-D-8
Assumed ACM mastic associated with Library D-15 and Office 500 SF
wall mounted book cases D-11 and
Library D-15, A.V.
Assumed ACM mastic associated with Classroom D-17, 500 SF
casework Corridor D-14, MAG D-
20,and Storage
Assumed ACM univent internals Library 12 EA
Assumed ACM locker mastic Corridor D-14 105 SF
Assumed ACM fire doors Throughout 20 EA
Assumed ACM TSI on small bore pipe
runs and fitting (concealed in plumbing Throughout 750 LF
walls and ceilings)
Block E
ettsi4
EHS-International,Inc. 10
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL QUANTITY
DESCRIPTION LOCATION EXPECTED TO BE
IMPACTED
Non-ACM 12"x12" light gray VCT with
non-ACM off-white and yellow mastic Corridor E-8 1,675 SF
on ACM residual black mastic on
concrete
Non-ACM 12"x12" blue VCT with non-
ACM yellow mastic on ACM residual Corridor E-8 1,675 SF
black mastic on concrete
Carpet with non-ACM yellow mastic on Vestibule E-25 125 SF
ACM residual black mastic on concrete
Carpet with non-ACM yellow mastic on
Social Studies
9"x9" light blue VAT w/ ACM black 105 SF
Classroom E-21
mastic on concrete
9"x9" Light brown VAT with ACM black Theater E-10 and 250 SF
mastic on concrete Control E-11
Carpet with non-ACM yellow and Drama Classroom E-1,
orange mastic on 9"x9" tan VAT w/ Green Room E-7 and 1,075 SF
ACM black mastic on concrete Dressing E-5
Drama Classroom E-1,
Assumed ACM white board mastic Passage E 2, and 26 EA
Classroom E-17 2001
Addition Classrooms 1-5
Drama Classroom E-1,
Assumed ACM mastic associated with Green Room E-7, S.S. 250 SF
wood wall paneling; Classroom E-21, and
Classroom E-17
Assumed ACM mastic associated with Corridor E-8 275 SF
wall panels
Assumed ACM wiring associated with Theater 30 EA
theatre stage lighting 350 LF
Assumed ACM mirror mastic Women E-4 3 EA
Assumed ACM fire doors Throughout 15 EA
Assumed ACM TSI on small bore pipe
runs and fitting (concealed in plumbing Throughout 750 LF
walls and ceilings)
Block F
Laundry F-2, Storage F-
Non-ACM 12"x12" off-white VCT (with 3, Cooking F-4, Office F-
brown, yellow, and white streaks) w/ 5, Dress F-6, Storage F- 3,425 SF
non-ACM yellow mastic on ACM 7, Sewing F-8, Storage
residual black mastic on concrete and Child Development
F-11
9"x9"Tan VAT (with brown and yellow
streaks) w/ ACM black mastic on Electrical F-1 50 SF
concrete _
e si
EHS-Intemationai.Inc. 10
•
Limited Hazardous Materials Survey Report
Federal Way High School
• EHSI Project 10527
July 12, 2013
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL QUANTITY
DESCRIPTION LOCATION EXPECTED TO BE
IMPACTED
9"x9" Light brown VAT (w/ rainbow
streaks) w/ ACM black mastic on Electrical F-1 50 SF
concrete
9"x9" Olive green VAT w/ ACM black Biology Classroom 1 and 2,745 SF
mastic on concrete 2
9"x9" Brown/red VAT (with beige
streaks) w/ ACM black mastic on Storage F-17 and F-18 265 SF
concrete
Carpet w/ non-ACM clear mastic on
12"x12" beige VAT (with brown Electronics F-19 and 2,325 SF
streaks) on ACM black mastic on Drafting F-16
concrete
Carpet with non-ACM yellow mastic
on"9x9" red VAT w/ ACM black mastic Special Education F-13 725 SF
on concrete
Carpet w/ non-ACM green/gray mastic
w/ non-ACM yellow mastic on 9"x9" Special Education F-15 700 SF
light brown VAT (w/ rainbow streaks)
w/ ACM black mastic on concrete
ACM black sink undercoat Sewing F 8, Electronics 3 EA
F-19 and Drafting F-16
Cooking F-4, Sewing F-
8, Child development F-
Assumed ACM mastic associated with 11, Special Ed F-13,15, 200 SF
wood wall paneling Drafting F-16,
Electronics F-19, and
Biology Classroom's
Assumed ACM wall panel mastic Corridor F-9, 10, and 15 1,000 SF
Cooking F-4, Sewing F-
8, Child development F-
Assumed ACM white board mastic 11, Special Ed F 13,15, 22 EA
Drafting F-16,
Electronics F-19, and
Biology Classroom's
Assumed ACM tack board mastic Special Ed F 13, 5 EA
Corridor F-15
Assumed ACM mirror mastic Toilet F-12 5 EA
ehsi•
EHS-International,Inc. 10
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL QUANTITY
LOCATION EXPECTED TO BE
DESCRIPTION
_ IMPACTED
Cooking F-4, Sewing F-
8, Child development F-
11, Special Ed F-13,15,
Assumed ACM mastic associated with Drafting F-16, 575 SF
casework Electronics F-19, and
Biology Classroom's,
Storage F-17 and 18,
Biology Prep Rooms
Assumed ACM locker mastic Corridor F-9, 10, and 15 200 SF
Assumed ACM electrical panels and Mechanical Room and 9 EA
components Electrical F-1
Assumed ACM fire doors Throughout 20 EA
Assumed ACM TSI on small bore pipe
runs and fitting (concealed in plumbing Throughout 750 LF
walls and ceilings)
Block G
Non-ACM 12"x12" light gray VCT (with
white and gray streaks), blue VAT, and
gray VAT (w/ maroon streaks) all w/ Corridor G-13 850 SF
non-ACM tan mastic on non-ACM white
leveling compound on gray VAT w/
ACM black mastic on wood
Blue/gray carpet with non-ACM tan Janitor G-9, Storage G-
mastic on tan VAT w/ ACM black 10A, Storage G-11, and 400 SF
mastic on wood Storage G-3
Conference G-2A,
Classroom G-2,
Blue/gray carpet with non-ACM tan Simulators G 1,
mastic on gray VAT w/ ACM black Business Classroom G-
5, 095 SF
4, Computer G-5,
mastic on wood Keyboard Classroom G-
6, and Micro Computer
G-7
Corridor G-13,
Conference G-2A,
Classroom G-2,
Assumed ACM mastic associated with Simulators G 1,
wood wall paneling Business Classroom G- 275 SF
4, Computer G-5,
Keyboard Classroom G-
6, and Micro Computer
G-7
(3hIs.
1 1
EHS-International,Inc.
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL QUANTITY
DESCRIPTION LOCATION EXPECTED TO BE
IMPACTED
Conference G-2A,
Classroom G-2,
Simulators G-1,
Assumed ACM mastic associated with Business Classroom G- 225 SF
casework 4, Computer G-5,
Keyboard Classroom G-
6, and Micro Computer
G-7
Classroom G-2,
Simulators G-1,
Business Classroom G-
Assumed ACM white board mastic 4, Computer G-5, 12 EA
Keyboard Classroom G-
6, and Micro Computer
G-7
Assumed ACM locker mastic Corridor G-13 50 SF
Assumed ACM electrical panels and Business Office G-10 4 EA
components
Assumed ACM fire doors Throughout 12 EA
Assumed ACM TSI on small bore pipe
runs and fitting (concealed in plumbing Throughout 750 LF
walls and ceilings)
Block H
Non-ACM 12"x12" beige VCT (w/ Main Corridor, Room
brown and white streaks) w/ ACM 704,705, and Office 2,750 SF
black mastic on concrete Area
Non-ACM white leveling compound on
non-ACM gray leveling compound on Janitor's Closet 5 SF
ACM residual black mastic on concrete
Multi-colored carpet w/ non-ACM foam
backing w/ non-ACM clear mastic on
non-ACM 12"x12" beige VCT (w/ brown ASA Room 975 SF
and white streaks) w/ ACM black
mastic on concrete
Assumed ACM mastic associated with ASA Room 25 SF
wood wall paneling
Assumed ACM white board mastic ASA Room, Room 704 6 EA
and 705
Assumed ACM tack board mastic ASA Room, Room 704 2 EA
and 705
Assumed ACM mastic associated with ASA Room, Room 704 50 SF
casework and 705
Assumed ACM locker mastic Main Corridor 50 SF
ehsi 4.0
EHS-International,Inc. 11
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL QUANTITY
DESCRIPTION LOCATION EXPECTED TO BE
IMPACTED
Assumed ACM electrical panels and Main Corridor 3 EA
components
Grooming, Boy's
Assumed ACM mirror mastic Restroom and Girl's 6 EA
Restroom
Assumed ACM fume hood baffles and Room 704 and 705 2 EA
internals
Assumed ACM fire doors Throughout 12 EA
Assumed ACM TSI on small bore pipe
runs and fitting (concealed in plumbing Throughout 750 LF
walls and ceilings)
Block J
Carpet w/ non-ACM yellow mastic on Math Classroom 3-5 and
9"x9" brown/red VAT w/ non-ACM 3-8 1 1,705 SF
mastic on concrete
Non-ACM 12"x12" light gray VCT w/
non-ACM dark gray mastic on 9"x9" Corridor 3-2 and 3-11 2 2,000 SF
light blue VAT (w/ white streaks) w/
black mastic on concrete
Carpet w/ non-ACM yellow mastic on
9"x9" tan VAT (w/ brown and yellow Math Classroom 3-7 and 1,700 SF
streaks) w/ non-ACM black mastic on Health 3-10 3
concrete
9"x9" Red VAT on ACM black mastic Math Classroom 3-9 and
beneath non-ACM carpet with non-ACM J_6 4 1,700 SF
carpet mastic on concrete
Assumed ACM mastic associated with Corridor 3-2, Math
wood wall paneling Classroom 3-5, 3-6, 3-7, 100 SF
J-8, 3-9, Health 3-10 5
Assumed ACM wall panel mastic Corridor 3-2 and J-11 6 250 SF
Assumed ACM tack board mastic Math Classroom J 9, 2 EA
Health J-10 7
Math Classroom 3-5, 3-
Assumed ACM white board mastic 6, 3-7, 3-8, 3-9, Health 24 EA
J-10 8
Assumed ACM locker mastic Corridor 3-11 50 SF
Assumed ACM mirror mastic Girls Restroom 1 EA
Assumed ACM fire doors Throughout 12 EA
Assumed ACM TSI on small bore pipe
runs and fitting (concealed in plumbing Throughout 750 LF
walls and ceilings)
Block K
ehsi
♦.
t>
EHS-International,Inc.
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL QUANTITY
DESCRIPTION LOCATION EXPECTED TO BE
IMPACTED
Carpet w/ non-ACM yellow/tan mastic
on 9"x9" red VAT w/ non-ACM black F.L. Classroom K 1, K 2, 2,085 SF
mastic on concrete Math Office K-2
9"x9"Tan floor tile with brown and
yellow streaks on non-ACM black F.L. Classroom K-9 845 SF
mastic beneath non-ACM carpet on
non-ACM yellow mastic on concrete
9"x9" Brown/red floor tile with beige
streaks on ACM black mastic on F.L. Office K 6 and 405 SF
concrete Conference K-7
Non-ACM 12"x12" dark gray floor tile
on non-ACM yellow mastic on 9"x9" Corridor K-5 1,000 SF
light blue VAT on ACM black mastic on
concrete
F.L. Classroom K-1,
Computer K-3, Math
Assumed ACM mastic associated with Classroom K 8, F.L.
wood wall paneling Classroom K-9, F.L 200 SF
Office K-6, Conference
K-7, F.L. Classroom K-4,
Math K-2
Assumed ACM wall panel mastic Corridor K-5 1,500 SF
Assumed ACM tack board mastic Computer K-3 1 EA
F.L. Classroom K-1,
Computer K-3, Math
Classroom K-8, F.L.
Assumed ACM white board mastic Classroom K-9, F.L 17 EA
Office K-6, Conference
K-7, F.L. Classroom K-4,
Math K-2
Assumed ACM locker mastic Corridor K-5 50 SF
Assumed ACM fire doors Throughout 10 EA
Assumed ACM TSI on small bore pipe
runs and fitting (concealed in plumbing Throughout 750 LF
walls and ceilings)
Block L
9"x9" Olive and light olive colored VAT Ceramics Lab L-5 1,635 SF
w/ ACM black mastic on concrete
9"x9" Green VAT (w/ beige streaks) w/ Art Lab L-1 1,185 SF
ACM black mastic on concrete
Blue/gray carpet w/ non-ACM tan
mastic on non-ACM white leveling
compound on 9"x9" red VAT w/ ACM Office L-8 200 SF
black mastic on concrete
e si..
EHS-International.Inc. I I
• 110
A
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL QUANTITY
LOCATION EXPECTED TO BE
DESCRIPTION
IMPACTED
Non-ACM red sheet vinyl flooring with Metal Shop L-13 and
non-ACM black asphaltic backing on Office L-9 4,000 SF
ACM black mastic on concrete
ACM gray caulking around metal Corridor L-6 735 LF
seismic wall brackets
Assumed ACM mastic associated with Art Lab L 1, Ceramics
wood wall paneling Lab L-5, Storage L-3 100 SF
and L-4 6
Assumed ACM mastic associated with Art Lab L-1 75 SF
casework
Assumed ACM electrical panels and Metal Shop L-13 6 EA
components
Assumed ACM tack board mastic Office L-2 1 EA
Assumed ACM white board mastic Art Lab L-land Shop 3 EA
Classroom L-7
Assumed ACM locker mastic Corridor L-6 125 SF
Assumed ACM fire doors Throughout 13 EA
Assumed ACM TSI on small bore pipe
runs and fitting (concealed in plumbing Throughout 750 LF
walls and ceilings)
Block M
9"x9" Olive colored VAT (w/ pink and
beige streaks) w/ ACM black mastic on Choral M-26 1,700 SF
concrete
Non-ACM 12"x12" blue VCT w/ non Corridor M-1 and
ACM yellow mastic on ACM residual 250 SF
Corridor M-12
black mastic on concrete
Non-ACM blue/gray carpet w/ non-ACM
tan mastic on 9"x9" Olive colored VAT Passage M-28, Practice 185 SF
(w/ pink and beige streaks) w/ ACM 3, M-29, and M-31
black mastic on concrete
Ensemble M-13, Practice
Non-ACM blue/gray carpet w/ non-ACM M 14, Practice M 15,
tan mastic on 9"x9" red VAT w/ non Instrument M 19, Office 1,375 SF
ACM black mastic on concrete M 20, Storage M 22,
Library M-23, Storage
_ M-24, Office M-25
Storage M-2, Mechanical
Non-ACM 12"x12" light gray VCT (w/ M-5, Office/Lab M-9,
maroon and white streaks) w/ ACM Storage M-34, Film M- 2,725 SF
black mastic on concrete 35, Print M-36, Print M-
37, Photo Lab M-38
ehsi.. i t
EI S-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL QUANTITY
DESCRIPTION LOCATION EXPECTED TO BE
IMPACTED
9"x9"Yellow floor tile (w/ brown and
black streaks) w/ ACM black mastic on Science Classroom M-11 1,455 SF
concrete
Physics Lab M-7,
Assumed ACM mastic associated with Chemistry Lab M-6 Band
wood wall paneling M-17, Office M-20, 175 SF
Storage M-22, Photo
Lab M-38
Physics Lab M-7 and
associated Offices,
Chemistry Lab M-6,
Office Lab M-9, Sicence
Classroom M-11,
Assumed ACM mastic associated with Ensemble M 13,
casework Instrument Storage M- 1, 500 SF
19, Office M-20, Storage
M-22, Library M-
23,Office M-25, Storage
M-34, Film M-35, Print
M-36, and Photo Lab M-
38
Assumed ACM locker mastic Corridor M-12 225 SF
Physics Lab M-7,
Chemistry Lab M-6,
Assumed ACM white board mastic Science Classroom M-
12 EA
11, Band M-17,Entry M-
18 Choral M-26, Photo
Lab M-38
Physics Lab M-7,
Assumed ACM fume hood baffles and Chemistry Office/Lab M- SEA
internals 9, Science Classroom M-
11,
Assumed ACM fire doors Throughout 15 EA
Assumed ACM TSI on small bore pipe
runs and fitting (concealed in plumbing Throughout 750 LF
walls and ceilings)
Tunnels
ACM TSI debris, at floor penetration Utility Tunnel L/M NW 20 SF
(4"OD pipe run) End
ACM Army green/gray cable bracket Utility Tunnel L/M, at 250 EA
mastic tunnel Hatch
ACM Black asphaltic vapor barrier Utility Tunnel A/B 550 SF
between concrete and wood forms
ACM TSI on abandon 8" pipe run Utility Tunnel A/B 4 LF
ehSim
EHS-International,Inc. 1 1
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL QUANTITY
LOCATION EXPECTED TO BE
DESCRIPTION
IMPACTED
JC on crawl space access door (3'x3') Block G Crawl Space 1 EA
Exterior
ACM White caulking on steel columns Exterior Block L/M 1,200 LF
ACM gray roll-up door frame caulking Exterior Block L 50 LF
JB'x 14')
ACM tan/gray door frame caulking Exterior Block F 15 EA
_(.8'x14')
ACM tan window frame caulking (3'x5') Exterior Block F 35 EA
ACM gray window frame caulking Exterior Block M 6 EA
J3'x5')
ACM black asphaltic tar beneath non-
ACM black asphaltic felt on concrete Block C Foundation 3,500 SF
foundation wall
Roof
ACM Silver coat on ACM black asphaltic Block A Roof 17 EA
tar on metal roof vent base
ACM Silver coat on ACM asphaltic built
up roofing on non ACM asphaltic vapor Block C Roof 1,000 SF
barrier on non-ACM brown paper vapor
barrier on wood roof deck
ACM black asphaltic sealant on parapet Block D Roof 200 LF
wall flashing
ACM Black asphaltic lead vent pipe Block M Roof 28 EA
penetration sealant
ACM Silver coat on non-ACM built-up
roofing on non-ACM black asphaltic Block M Roof 75 SF
vapor barrier on non-ACM asphaltic tar
on concrete
ACM black asphaltic sealant on non-
ACM black asphaltic built-up roofing Block M Roof 25 SF
with tar beneath non-ACM silver coat
ACM Black asphaltic tar on ACM built-
up roofing on non-ACM black asphaltic
P1 Roof 1,000 SF
vapor barrier on non-ACM brown paper
vapor barrier on wood roof deck
ACM black asphaltic roof repair patch P1 Roof 15 SF
Covered Walkways
ACM Black asphaltic coating beneath Center Courtyard 5,600 SF
non-ACM beige and white paint
Portables (P1)
ACM White wall cover backing Interior Walls I 1,200 SF
e 51..E
11
EHIS-International,Inc.
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
FEDERAL WAY HIGH SCHOOL
ASBESTOS MATERIAL QUANTITY
DESCRIPTION LOCATION EXPECTED TO BE
IMPACTED
ACM gray window frame glazing putty Exterior Windows 14 EA
(4'x8') and (3'x4')
Assumed ACM electrical panels and Classroom 1 EA
components
Assumed ACM chalkboard mastic Classroom 1 EA
Community Pool
Non-ACM dark blue rubber flooring
with non-ACM white/beige mastic on Office and Lobby 1 500 SF
tan VAT w/ ACM black mastic on
concrete
ACM white cloth flex duct (4'x4') Boiler Room 2 4 EA
ACM red seam sealant on ACM black
Boiler Room 3 100 LF
sealant (on AHU)
ACM silver paint on boiler exterior Boiler Room 4 15 SF
ACM TSI on boiler exhaust duct Boiler Room 5 200 LF
(2'diameter)
ACM brown/black glue dots associated Office 6 2 EA
with fiber board wall panel (4'x8')
ACM white cloth flex duct (3'x3') Men's and Women's 6 EA
Locker Room Attic 7
AHU with assumed ACM internal Boiler Room 8 3 EA
components
Assumed ACM electrical panels Boiler Room and Boiler 15 EA
Room Office 9
Assumed ACM fire doors Throughout 4 EA
Assumed ACM flange gaskets Boiler Room 30 EA
(associated with the boiler);
Assumed ACM boiler internal Boiler Room 1 EA
components
Assumed ACM wall panels and Over Pool 1800 SF
associated mastic (High bay pool area);
Assumed ACM TSI on small bore pipe
runs and fitting (concealed in plumbing Throughout 2,250 LF
walls and ceilings)
Assumed ACM TSI on large bore pipe
runs and fittings under slab (associated Under concrete slab 2,250 LF
with pool).
ACM identified in this survey should not be disturbed unless handled by personnel who are
properly trained and certified in asbestos work. Demolition and/or renovation activities by
contractors may expose concealed suspect ACM. Contractors should be aware of the
potential for concealed suspect ACM and have preplanned contingencies for the handling of
suspect ACM discovered during renovation and/or demolition work. Any concealed suspect
ehsi�a
EHS-International,Inc. 1 1
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
ACM material that was not sampled or was assumed to be ACM and included in this report,
must be treated as ACM until proven otherwise by a Certified AHERA Building Inspector and
a certified laboratory. Contingency plans should include stopping work on identification of
concealed suspect ACM, evacuation of the area, and sampling by a Certified AHERA Building
Inspector. Concealed suspect material may include, but is not limited to: non-fiberglass
pipe or roof drain insulation; spray-applied coatings; cementitious board; asphalt or paper
vapor barriers; vinyl floorings and mastics.
2.4.2 Lead-Containing Paint and Building Materials
Seven hundred sixty-six (766) samples were analyzed for lead using the X-Ray fluorescence
(XRF) analyzer. Results marked with "<LOD" are less than the limit of detection. XRF paint
sample results ranged from 9.4 milligrams of lead per square centimeter (mg Pb/cm2) to
less than the LOD and XRF sample results for lead-containing materials ranged from 37 mg
Pb/cm2 to less than the LOD. The results are provided in a table 3 of this report. The
results indicate that ninety-eight (98) of the materials were found to contain >_1.0 mg/cm2
lead using the XRF instrument and two hundred and two (202) of the surfaces were found
to contain detectable levels of lead using the XRF. Bolded results indicate materials
coated with "lead-based paint" (e.g., >1.0 mg/cm2) as defined by USEPA
regulation 40CFR745 and Washington State Department of Commerce (Commerce)
regulation WAC 365-230.
In addition to the XRF samples, EHSI collected forty (40) bulk QA samples for laboratory
analysis. Results marked with the "<" symbol are less than the detectable level. Bulk
sample results ranged from 4.6000 to <0.0035 percent lead by weight. Building materials
and paint containing detectable levels of lead are considered regulated by DOSH. Two (2) of
the Quality Assurance (QA) bulk samples were found to contain levels of lead above 0.5
percent by weight and thirteen (13) of the QA bulk samples were found to contain
detectable levels of lead.
Table 3 summarizes XRF lead samples, including sample number, material description,
substrate, color, location and analytical results.
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Component Substrate Color Room Building Lead Conc.
(mg/cm2)
1 SELF- N/A N/A N/A N/A 2.67
CALIBRATION
2 CALIBRATION N/A RED N/A N/A 1
3 CALIBRATION N/A RED N/A N/A 1
4 CALIBRATION N/A RED N/A N/A 1
5 WALL CONCRETE BEIGE SMALL GYM BLOCK Al < LOD
805
6 WALL GWB BEIGE SMALL GYM BLOCK Al < LOD
805
7 VENT COVER METAL BEIGE SMALL GYM BLOCK Al < LOD
805
ehsi 11
ENS-International,Inc.
0 0
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Lead Conc.
# Component Substrate Color Room Building
(mg/cm z)
8 DOOR FRAME METAL LIGHT SMALL GYM BLOCK Al < LOD
BROWN 805
9 DOOR METAL LIGHT SMALL GYM BLOCK Al < LOD
BROWN 805
10 DOUBLE METAL BEIGE SMALL GYM BLOCK Al < LOD
DOOR FRAME 805
11 DOUBLE METAL BEIGE SMALL GYM BLOCK Al < LOD
DOOR 805
12 MIRROR WOOD WHITE SMALL GYM BLOCK Al 0.4
CABINET 805
13 WALL TRIM WOOD WHITE SMALL GYM BLOCK Al < LOD
805
14 WALL CMU WHITE CORRIDOR BLOCK Al < LOD
A35
15 FIRE METAL WHITE CORRIDOR BLOCK Al < LOD
EXTINGUISHE A35
R CABINET
16 DOOR FRAME METAL BLUE ROOM 804 BLOCK A2 < LOD
17 WALL CONCRETE BLUE WEIGHT BLOCK A2 < LOD
ROOM 806
18 SOFFIT GWB WHITE WEIGHT BLOCK A2 < LOD
ROOM 806
19 WALL CMU BEIGE MEN LOCKER BLOCK A2 < LOD
ROOM 814
20 WINDOW METAL LIGHT MEN LOCKER BLOCK A2 < LOD
FRAME BROWN ROOM 814
21 WALL CERAMIC WHITE MEN LOCKER BLOCK A2 < LOD
ROOM 814
22 FLOOR CERAMIC TAN MEN LOCKER BLOCK A2 < LOD
ROOM 814
23 COVE BASE CERAMIC ORANGE MEN LOCKER BLOCK A2 < LOD
ROOM 814
24 CEILING GWB BEIGE MEN LOCKER BLOCK A2 < LOD
ROOM 814
25 CEILING PLASTER BEIGE MEN LOCKER BLOCK A2 < LOD
ROOM 814
26 ATTIC METAL BEIGE MEN LOCKER BLOCK A2 < LOD
ACCESSROOM 814
DOOR
27 ATTIC METAL BEIGE MEN LOCKER BLOCK A2 < LOD
ACCESS ROOM 814
DOOR
28 SPEAKER BOX METAL BLACK MEN LOCKER BLOCK A2 < LOD
ROOM 814
29 DOOR FRAME METAL BEIGE MEN LOCKER BLOCK A2 < LOD
ROOM 814
30 DOOR METAL GRAY MEN LOCKER BLOCK A2 < LOD
ROOM 814
ehsi 6.4 ,1
ENS-International,Inc,
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527 `
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Lead Conc.
Component Substrate Color Room Building Z
# (mg/cm )
31 LOCKERS METAL BLUE MEN LOCKER BLOCK A2 < LOD
ROOM 814
32 ELECTRICAL METAL GRAY MEN LOCKER BLOCK A2 < LOD
BOX ROOM 814
33 CONDUIT METAL BEIGE MEN LOCKER BLOCK A2 1.3
ROOM 814
34 EXHAUST FAN METAL BEIGE MEN LOCKER BLOCK A2 < LOD
ROOM 814
35 CEILING WOOD BEIGE MEN LOCKER BLOCK A2 < LOD
ROOM 814
36 CEILING WOOD BEIGE MEN LOCKER BLOCK A2 0.08
ROOM 814
37 STALL WOOD BLUE MEN LOCKER BLOCK A2 < LOD
ROOM 814
38 CEILING CONCRETE BEIGE MEN LOCKER BLOCK A2 < LOD
ROOM 814
39 SINK METAL BEIGE MEN LOCKER BLOCK A2 0.18
ROOM 814
40 SPRINKLER METAL BEIGE MEN LOCKER BLOCK A2 0.17
PIPE ROOM 814
41 FLOOR CERAMIC BEIGE MEN LOCKER BLOCK A2 < LOD
ROOM 814
42 WALL CERAMIC WHITE MEN LOCKER BLOCK A2 22.4
ROOM 814
43 CEILING PLASTER WHITE MEN LOCKER BLOCK A2 < LOD
RM 814
44 CEILING PLASTER WHITE MEN LOCKER BLOCK A2 < LOD
RM 814
45 CEILING PLASTER WHITE MEN LOCKER BLOCK A2 < LOD
ON RM 814
SILVER
46 WALL GWB LIGHT MAIN GYM BLOCK Al < LOD
BROWN
47 SUPPORT METAL BEIGE MAIN GYM BLOCK Al 0.12
BRACE
48 WALL CMU WHITE MAIN GYM BLOCK Al < LOD
49 WALL CONCRETE OFF MAIN GYM BLOCK Al < LOD
WHITE
50 COLUMN CONCRETE OFF MAIN GYM BLOCK Al < LOD
WHITE
51 ELECTRICAL METAL GRAY MAIN GYM BLOCK Al < LOD
PANEL
52 ELECTRICAL METAL GRAY MAIN GYM BLOCK Al < LOD
PANEL
53 FLOOR WOOD BLUE MAIN GYM BLOCK Al < LOD
MARKING
54 FLOOR WOOD RED MAIN GYM BLOCK Al < LOD
MARKING
elhiSi 416.
EHS-International,Inc. 12
•
•
.
Limited Hazardous Materials Survey Report
Federal Way High School
' EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Lead Conc.
Component Substrate Color Room Building
#' (mg/cm2)
55 FLOOR WOOD WHITE MAIN GYM BLOCK Al < LOD
MARKING
56 DUCTING METAL BEIGE MAIN GYM BLOCK Al < LOD
STORAGE RM
57 HATCH METAL BROWN MAIN GYM BLOCK Al < LOD
STORAGE RM
58 DOOR FRAME METAL BEIGE UPPER GYM BLOCK A2 < LOD
59 STAIR METAL BLUE UPPER GYM BLOCK A2 < LOD
RAILING
60 STAIR TREAD CONCRETE BLUE UPPER GYM BLOCK A2 < LOD
61 WALL GWB BEIGE UPPER GYM BLOCK A2 < LOD
62 GUARD METAL BLUE UPPER GYM BLOCK A2 < LOD
RAILING
63 DRAIN PIPE METAL WHITE UPPER GYM BLOCK A2 1
ROOM 808
64 DRAIN PIPE METAL WHITE UPPER GYM BLOCK A2 0.8
ROOM 808
65 DRAIN PIPE METAL WHITE UPPER GYM BLOCK A2 < LOD
ROOM 808
66 HATCH METAL WHITE UPPER GYM BLOCK A2 < LOD
ROOM 808
67 CALIBRATION N/A RED CALIBRATION N/A 0.9
68 CALIBRATION N/A RED CALIBRATION N/A 1
69 CALIBRATION N/A RED CALIBRATION N/A 1
70 SELF- N/A N/A SELF- N/A 2.41
CALIBRATION CALIBRATION
71 CALIBRATION N/A RED CALIBRATION N/A 1
72 CALIBRATION N/A RED CALIBRATION N/A 1
73 CALIBRATION N/A RED CALIBRATION N/A 1
74 WALL GWB YELLOW KITCHEN BLOCK B < LOD
75 WALL GWB BLUE KITCHEN BLOCK B < LOD
76 WALL GWB BEIGE KITCHEN BLOCK B < LOD
77 WALL GWB BEIGE KITCHEN BLOCK B < LOD
78 FLOOR CERAMIC RED KITCHEN BLOCK B < LOD
79 DOOR FRAME METAL BLUE KITCHEN BLOCK B < LOD
80 DOOR FRAME METAL BLUE KITCHEN BLOCK B < LOD
81 DOOR FRAME METAL YELLOW KITCHEN BLOCK B < LOD
82 COLUMN WOOD YELLOW KITCHEN BLOCK B < LOD
83 COLUMN WOOD YELLOW KITCHEN BLOCK B < LOD
84 COLUMN WOOD YELLOW KITCHEN BLOCK B < LOD
ehs/..
EHS-International,Inc. 12
• • .
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Component Substrate Color Room Building Lead Conc.
_ r (mg/cm )
85 COLUMN WOOD BLUE CAFETERIA BLOCK B 0.7
86 BEAM WOOD BLUE CAFETERIA BLOCK B 1.4
87 DOOR FRAME METAL BLUE CAFETERIA BLOCK B < LOD
88 DOOR METAL YELLOW CAFETERIA BLOCK B < LOD
89 COLUMN WOOD BLUE CAFETERIA BLOCK B 0.9
90 COLUMN METAL BLUE CAFETERIA BLOCK B < LOD
91 WALL PLASTER BLUE CAFETERIA BLOCK B < LOD
92 WALL PLASTER WHITE CAFETERIA BLOCK B < LOD
93 ROLLUP METAL WHITE CAFETERIA BLOCK B < LOD
DOOR FRAME
94 MESH METAL BLUE CAFETERIA BLOCK B < LOD
SCREEN
DOOR
95 WALL CONCRETE WHITE CAFETERIA BLOCK B 0.08
96 CEILING GWB WHITE CAFETERIA BLOCK B < LOD
97 WALL GWB WHITE CAFETERIA BLOCK B < LOD
98 WALL GWB WHITE CAFETERIA BLOCK B < LOD
99 TRUSS METAL WHITE CAFETERIA BLOCK B < LOD
100 CEILING METAL WHITE CAFETERIA BLOCK B < LOD
101 RECEPTION WOOD WHITE CAFETERIA BLOCK B < LOD
COUNTER
102 WALL CERAMIC YELLOW KITCHEN BLOCK B < LOD
103 WINDOW METAL BEIGE KITCHEN BLOCK B 0.04
FRAME
104 DOOR FRAME METAL BEIGE KITCHEN BLOCK B 0.05
105 DOOR METAL BEIGE KITCHEN BLOCK B < LOD
106 WINDOW SILL WOOD WHITE KITCHEN BLOCK B < LOD
107 WALL CMU WHITE KITCHEN BLOCK B 0.08
108 RAILING METAL BLUE CAFETERIA BLOCK B < LOD
109 SPRINKLER METAL OFF CAFETERIA BLOCK B < LOD
PIPE WHITE FILE STORAGE
110 SPRINKLER METAL OFF CAFETERIA BLOCK B < LOD
PIPE WHITE FILE STORAGE
111 DOOR FRAME METAL BLUE CAFETERIA BLOCK B < LOD
FILE STORAGE
112 DOOR METAL BLUE CAFETERIA BLOCK B < LOD
FILE STORAGE
113 CEILING GWB BEIGE CAFETERIA BLOCK B < LOD
FILE STORAGE
114 WALL GWB BEIGE CAFETERIA BLOCK B < LOD
* FILE STORAGE
sle 12
EHS-International,Inc.
. . . •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Component Substrate Color Room Building Lead Conc.
# (mg/cm2)
115 DUCT METAL WHITE CAFETERIA BLOCK B < LOD
FILE STORAGE
116 CALIBRATION N/A RED CALIBRATION N/A 0.9
117 CALIBRATION N/A RED CALIBRATION N/A 0.9
118 CALIBRATION N/A RED CALIBRATION N/A 1
119 SELF- N/A N/A SELF- N/A 2.65
CALIBRATION CALIBRATION
120 CALIBRATION N/A RED CALIBRATION N/A 1
121 CALIBRATION N/A RED CALIBRATION N/A 1
122 CALIBRATION N/A RED CALIBRATION N/A 0.9
123 WALL CERAMIC YELLOW WOMEN BLOCK Al < LOD
LOCKER ROOM
124 FLOOR CERAMIC TAN WOMEN BLOCK Al 0.05
LOCKER ROOM
125 WALL GWB BEIGE WOMEN BLOCK Al < LOD
LOCKER ROOM
126 CEILING GWB BEIGE WOMEN BLOCK Al < LOD
LOCKER ROOM
127 DOOR FRAME METAL LIGHT WOMEN BLOCK Al < LOD
BROWN LOCKER ROOM
128 STAIRCASE METAL LIGHT BOILER ROOM BLOCK A2 0.03
RAILING BROWN
129 DOOR FRAME METAL BEIGE BOILER ROOM BLOCK A2 0.04
130 DOOR METAL BEIGE BOILER ROOM BLOCK A2 < LOD
131 WALL GWB BEIGE BOILER ROOM BLOCK A2 < LOD
132 PANELBOARD METAL GRAY BOILER ROOM BLOCK A2 < LOD
133 ELECTRICAL METAL GRAY BOILER ROOM BLOCK A2 < LOD
PANEL
134 ELECTRICAL METAL DARK BOILER ROOM BLOCK A2 < LOD
PANEL GRAY
135 TANK METAL BLACK BOILER ROOM BLOCK A2 < LOD
136 TANK METAL GRAY BOILER ROOM BLOCK A2 < LOD
137 CIRCULATION METAL RED BOILER ROOM BLOCK A2 0.1
PUMP
138 TANK METAL RED BOILER ROOM BLOCK A2 < LOD
139 TANK METAL RED BOILER ROOM BLOCK A2 < LOD
140 PIPE METAL RED BOILER ROOM BLOCK A2 < LOD
141 PIPE METAL RED BOILER ROOM BLOCK A2 < LOD
142 BOILER METAL BLUE BOILER ROOM BLOCK A2 < LOD
143 HOT WATER METAL TAN BOILER ROOM BLOCK A2 0.04
HEATER
144 BOILER PLATE METAL BLACK BOILER ROOM BLOCK A2 < LOD
e si4 ,2
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Lead Conc.
# Component Substrate Color Room Building g�
m cm2)
145 CALIBRATION N/A RED CALIBRATION N/A 0.9
146 CALIBRATION N/A RED CALIBRATION N/A 1.4
147 CALIBRATION N/A RED CALIBRATION N/A 1
148 SELF- N/A N/A SELF- N/A 2.38
_ CALIBRATION CALIBRATION
149 CALIBRATION N/A RED CALIBRATION N/A 0.9
150 CALIBRATION N/A RED CALIBRATION N/A 1
151 CALIBRATION N/A RED CALIBRATION N/A 1
152 WALL CONCRETE WHITE NORTH BLOCK C 0.06
CORRIDOR
153 DOOR FRAME METAL LIGHT NORTH BLOCK C < LOD
BROWN CORRIDOR
154 DOOR METAL LIGHT NORTH BLOCK C < LOD
BROWN CORRIDOR
155 WALL CONCRETE YELLOW NORTH BLOCK C 0.04
CORRIDOR
156 WALL GWB OFF NORTH BLOCK C < LOD
WHITE CORRIDOR
157 ELECTRICAL METAL TAN NORTH BLOCK C < LOD
PANEL CORRIDOR
158 WINDOW METAL WHITE NORTH BLOCK C 0.4
FRAME CORRIDOR
159 WINDOW SILL CONCRETE WHITE NORTH BLOCK C 0.09
CORRIDOR
160 ELECTRICAL METAL GRAY CUSTODIAL BLOCK C < LOD
PANEL OFFICE
161 TRANSFORME METAL GRAY CUSTODIAL BLOCK C < LOD
R OFFICE
162 CEILING TILE FIBER WHITE CUSTODIAL BLOCK C < LOD
BOARD OFFICE
163 SPRINKER METAL RED SPRINKLER BLOCK C < LOD
PIPE CLOSET
164 SPRINKER METAL RED SPRINKLER BLOCK C 0.3
PIPE FITTING CLOSET
165 SPRINKER METAL BLACK SPRINKLER BLOCK C < LOD
PIPE FITTING CLOSET
166 SPRINKER METAL BLUE SPRINKLER BLOCK C < LOD
PIPE FITTING CLOSET
167 COMPRESSOR METAL BLUE SPRINKLER BLOCK C < LOD
CLOSET
168 CEILING PLASTER BEIGE SPRINKLER BLOCK C < LOD
CLOSET
169 WALL PLASTER BROWN CENTRAL BLOCK C < LOD
CORRIDOR
170 WALL PLASTER OFF CENTRAL BLOCK C < LOD
WHITE CORRIDOR
e si
EHIS-International,Inc. 12
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Lead Conc.
Component Substrate Color Room Building (mg/cm2)
171 RAM RAILING METAL BROWN CENTRAL BLOCK C < LOD
CORRIDOR
172 STAIRCASE METAL BLUE CENTRAL BLOCK C < LOD
RAILING CORRIDOR
173 COLUMN PLASTER BROWN CENTRAL BLOCK C < LOD
CORRIDOR
174 ROLLUP METAL TAN CENTRAL BLOCK C < LOD
DOOR CORRIDOR
175 ROLLUP METAL TAN CENTRAL BLOCK C < LOD
DOOR CORRIDOR
176 DOOR FRAME METAL BLUE CENTRAL BLOCK C < LOD
CORRIDOR
177 ELEVATOR METAL BLUE CENTRAL BLOCK C < LOD
DOOR FRAME CORRIDOR
178 ELEVATOR METAL TAN CENTRAL BLOCK C < LOD
DOOR CORRIDOR
179 WINDOW METAL BLUE CENTRAL BLOCK C < LOD
CORRIDOR
180 WALL GWB BROWN CENTRAL BLOCK C < LOD
CORRIDOR
181 WALL GWB LIGHT CENTRAL BLOCK C < LOD
BLUE CORRIDOR
182 WALL GWB LIGHT GIRLS BLOCK C < LOD
GREEN RESTROOM
183 STALL METAL LIGHT GIRLS BLOCK C 3.1
GREEN RESTROOM
184 WALL CERAMIC OFF MEN BLOCK C 21.4
WHITE RESTROOM
185 FLOOR CERAMIC BEIGE MEN BLOCK C < LOD
RESTROOM
186 STALL WOOD BLUE MEN BLOCK C < LOD
RESTROOM
187 WALL CMU BEIGE FIRE ALARM BLOCK C 0.4
CABINET
188 TRANSFORME METAL GRAY FIRE ALARM BLOCK C < LOD
R CABINET
189 SWITCH METAL GRAY FIRE ALARM BLOCK C 0.03
BOARD CABINET
190 FLOOR CONCRETE GRAY FIRE ALARM BLOCK C 1.4
CABINET
191 DOOR FRAME METAL BEIGE FIRE ALARM BLOCK C < LOD
CABINET
192 DOOR METAL BEIGE FIRE ALARM BLOCK C < LOD
CABINET
193 DOOR METAL BEIGE FIRE ALARM BLOCK C < LOD
CABINET
194 LOCKERS METAL BLUE SOUTH BLOCK C < LOD
CORRIDOR
etsio
EHS-International,Inc. 12
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527 '
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Lead Conc.
# Component Substrate Color Room Building (mg/cm2)
195 WALL GWB BEIGE FACULTY 102 BLOCK C < LOD
196 CABINET WOOD BEIGE FACULTY 102 BLOCK C < LOD
197 WINDOW WOOD BEIGE FACULTY 102 BLOCK C 0.5
FRAME
198 WINDOW SILL WOOD BEIGE FACULTY 102 BLOCK C < LOD
199 WALL GWB LIGHT 201 BLOCK C < LOD
BLUE
200 WINDOW SILL WOOD LIGHT 201 BLOCK C 0.28
BLUE
201 DOOR FRAME METAL BEIGE 201 BLOCK C < LOD
202 WINDOW SILL WOOD BEIGE 207 BLOCK C 0.16
203 WALL GWB BEIGE 207 BLOCK C < LOD
204 ELECTRICAL METAL GRAY CUSTODIAL BLOCK C < LOD
PANEL CLOSET
205 WALL GWB YELLOW BOYS BLOCK C < LOD
206 FLOOR CONCRETE BROWN BOYS BLOCK C 0.8
207 STALL METAL YELLOW BOYS BLOCK C 4.2
208 WALL HATCH WOOD YELLOW BOYS BLOCK C < LOD
DOOR
209 BOILER METAL BLUE BOILER ROOM BLOCK C < LOD
210 HOT WATER METAL TAN BOILER ROOM BLOCK C 0.07
HEATER
211 WALL BRICK RED BOILER ROOM BLOCK C < LOD
212 DRAIN PIPE METAL BEIGE BOILER ROOM BLOCK C < LOD
213 WALL CONCRETE BEIGE BOILER ROOM BLOCK C < LOD
214 WALL CONCRETE BEIGE BOILER ROOM BLOCK C < LOD
215 WALL CONCRETE BEIGE BOILER ROOM BLOCK C < LOD
216 COLUMN CONCRETE BEIGE BOILER ROOM BLOCK C < LOD
217 TANK METAL SILVER BOILER ROOM BLOCK C < LOD
218 WINDOW METAL OFF BOILER ROOM BLOCK C 0.26
FRAME WHITE
219 CONDUIT METAL BEIGE BOILER ROOM BLOCK C < LOD
220 CIRCULATION METAL RED BOILER ROOM BLOCK C < LOD
PUMP
221 ELECTRICAL METAL DARK BOILER ROOM BLOCK C < LOD
PANEL GRAY
222 FLOOR CONCRETE GRAY BOILER ROOM BLOCK C < LOD
223 DOOR FRAME METAL BROWN BOILER ROOM BLOCK C < LOD
224 DOOR METAL BROWN BOILER ROOM BLOCK C 0.07
225 BURNER METAL BLUE BOILER ROOM BLOCK C < LOD
ehsi.
12
EHS-International,Inc.
s .
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Component Substrate Color Room Building Lead Conc.
# (mg/cm2)
PANEL BOARD
226 ELECTRICAL METAL GRAY BOILER ROOM BLOCK C < LOD
PANEL
227 CALIBRATION N/A RED CALIBRATION N/A 1
228 CALIBRATION N/A RED CALIBRATION N/A 1
229 CALIBRATION N/A RED CALIBRATION N/A 1
230 SELF- N/A N/A SELF- N/A 2.57
CALIBRATION CALIBRATION
231 CALIBRATION N/A RED CALIBRATION N/A 1
232 CALIBRATION N/A RED CALIBRATION N/A 0.9
233 CALIBRATION N/A RED CALIBRATION N/A 0.9
234 WALL GWB BLUE LIBRARY 108 BLOCK D < LOD
235 DOOR FRAME METAL BEIGE LIBRARY 108 BLOCK D < LOD
236 WALL GWB YELLOW LIBRARY 108 BLOCK D < LOD
237 WALL GWB YELLOW LIBRARY 108 BLOCK D < LOD
238 WALL CERAMIC BEIGE LIBRARY 108 BLOCK D < LOD
239 WALL GWB LIGHT LIBRARY 108 BLOCK D 0.03
GREEN
240 DOOR FRAME METAL BEIGE LIBRARY 108 BLOCK D < LOD
241 DOOR METAL BEIGE LIBRARY 108 BLOCK D 0.04
242 WINDOW METAL BEIGE LIBRARY 108 BLOCK D < LOD
FRAME INT
OFFICE
243 WINDOW METAL BEIGE LIBRARY 108 BLOCK D < LOD
FRAME INT
OFFICE
244 WALL METAL BURGUN LIBRARY 108 BLOCK D < LOD
DY
245 DOOR FRAME METAL DARK LIBRARY 108 BLOCK D < LOD
BLUE
246 WINDOW WOOD OFF LIBRARY 108 BLOCK D 0.08
FRAME WHITE
247 WINDOW WOOD OFF LIBRARY 108 BLOCK D < LOD
FRAME WHITE
248 WINDOW WOOD OFF LIBRARY 108 BLOCK D 0.14
FRAME WHITE
249 WINDOW SILL WOOD OFF LIBRARY 108 BLOCK D < LOD
WHITE
250 RADIATOR METAL TAN LIBRARY 108 BLOCK D < LOD
251 CEILING GWB WHITE LIBRARY 108 BLOCK D < LOD
252 CEILING GWB WHITE LIBRARY 108 BLOCK D < LOD
253 PARTITION WOOD BEIGE LIBRARY 108 BLOCK D < LOD
ehs/•4
EHS-International,Inc. 12
w 0
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Component Substrate Color Room Building Lead Conc.
# (mg/cm )
254 PARTITION WOOD BEIGE LIBRARY 108 BLOCK D < LOD
255 PARTITION WOOD BEIGE LIBRARY 108 BLOCK D < LOD
256 PARTITION WOOD BEIGE LIBRARY 108 BLOCK D < LOD
257 WALL CORKBOAR BLACK LIBRARY 108 BLOCK D 9.9
D
258 WALL CORKBOAR BLACK LIBRARY 108 BLOCK D 9.4
D
259 WALL GWB OFF CENTRAL BLOCK D < LOD
WHITE CORRIDOR
260 WALL GWB OFF CENTRAL BLOCK D < LOD
WHITE CORRIDOR
261 WALL BRICK OFF CENTRAL BLOCK D < LOD
WHITE CORRIDOR
262 LOCKER METAL BLUE CENTRAL BLOCK D < LOD
CORRIDOR
263 WINDOW CONCRETE OFF CENTRAL BLOCK D < LOD
WHITE CORRIDOR
264 RAILING METAL DARK CENTRAL BLOCK D < LOD
BLUE CORRIDOR
265 WALL BRICK DARK CENTRAL BLOCK D < LOD
BLUE CORRIDOR
266 SWITCHBOAR METAL GRAY MECH ROOM BLOCK D < LOD
D
267 ELECTRICAL METAL GRAY MECH ROOM BLOCK D < LOD
PANEL FRONT
268 ELECTRICAL METAL YELLOW MECH ROOM BLOCK D < LOD
PANEL SIDE
269 WALL GWB BLUE 109 BLOCK D < LOD
270 DOOR TRIM WOOD BROWN CENTRAL BLOCK D < LOD .
CORRIDOR
271 CALIBRATION N/A RED CALIBRATION N/A 0.9
272 CALIBRATION N/A RED CALIBRATION N/A 0.9
273 CALIBRATION N/A RED CALIBRATION N/A 0.9
274 SELF- N/A N/A SELF- N/A 2.62
CALIBRATION CALIBRATION
275 CALIBRATION N/A RED CALIBRATION N/A 0.9
276 CALIBRATION N/A RED CALIBRATION N/A 1
277 CALIBRATION N/A RED CALIBRATION N/A 1
278 CALIBRATION N/A RED CALIBRATION N/A 1
279 CALIBRATION N/A RED CALIBRATION N/A 1
280 WALL GWB DARK HALL E < LOD
BROWN
281 WALL GWB WHITE HALL E < LOD
ehsi. 12
EHS-Inteirnational,Inc.
• • •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Lead Conc.
# Component Substrate Color Room Building (mg/cm2)
282 ELECTRICAL METAL WHITE HALL E < LOD
PANEL
283 COAT RACK WOOD RED 605 E < LOD
284 ELECTRICAL METAL DARK HALL E < LOD
PANEL GRAY
285 WHITE DRY ERASE WHITE 603 E < LOD
BOARD BOARD
286 COUNTER TOP PLYWOOD BLACK 603 E < LOD
287 WALL METAL BLUE 121 E < LOD
288 DOOR FRAME METAL BEIGE 191 E < LOD
289 WALL GWB LIGHT 119 E < LOD
BLUE
290 WALL GWB LIGHT 119 E < LOD
BLUE
291 WALL GWB TAN 601 E < LOD
292 CONDUIT PLASTIC TAN 601 E 1.9
COVER
293 DOOR METAL TAN 602 E < LOD
WINDOW
FRAME
294 CONDUIT METAL TAN 602 E < LOD
COVER
295 ELECTRICAL METAL TAN 602 E < LOD
BOX
296 ELECTRICAL METAL TAN 602 E < LOD
BOX
297 WALL GWB NEON 602 E < LOD
GREEN
298 LOCKER METAL BLUE HALL E < LOD
299 DOOR FRAME WOOD BLACK 607 THEATER E < LOD
300 WALL GWB BLACK 607 THEATER E < LOD
301CONDUIT METAL BLACK 607 THEATER E 0.2
PIPE
302 ELECTRICAL METAL BLACK 607 THEATER E < LOD
BOX
303 WINDOW SILL WOOD TAN 607 THEATER E 0.04
304 WINDOW WOOD TAN 607 THEATER E < LOD
FRAME
305 LOWER WOOD GRAY 607 THEATER E < LOD
STAGE FLOOR
306 STAGE STEPS WOOD BLACK 607 THEATER E < LOD
307 MAIN STAGE WOOD RED 607 THEATER E < LOD
FLOOR
308 MAIN STAGE WOOD RED 607 THEATER E < LOD
FLOOR
e si..
EHS-International,Inc. 12
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Lead Conc.
# Component Substrate Color Room Building (mg/cm2)
309 MAIN STAGE WOOD BLACK 607 THEATER E < LOD
FLOOR
310 121N SACT ACT BLACK 607 THEATER E < LOD
ON WALL
311 12IN SACT ACT BLACK 607 THEATER E < LOD
ON WALL
312 12IN SACT ACT BLACK 607 THEATER E < LOD
ON WALL
313 RAILING METAL BLUE HALL E < LOD
314 WALL GWB LIGHT WOMEN E 0.07
GREEN BATHROOM
315 TRIM WOOD DARK MEN E < LOD
PURPLE BATHROOM
316 WALL GWB DARK WOMEN E 0.07
PURPLE BATHROOM
317 COVE BASE CERAMIC WHITE WOMEN E 14.3
TILE BATHROOM
318 FLOOR CERAMIC GRAY WOMEN E < LOD
TILE BATHROOM
319 FLOOR CERAMIC GRAY WOMEN E < LOD
TILE BATHROOM
320 STALLS PLYWOOD DARK WOMEN E < LOD
PURPLE BATHROOM
321 SPLASHGUA CERAMIC WHITE WOMEN E 16.2
RD WALL TILE BATHROOM
322 WALL GWB LIGHT BOYS E < LOD
GREEN BATHOOM _
323 WALL TRIM WOOD DARK BOYS E < LOD
GREEN BATHOOM
324 WALL METAL DARK BOYS E < LOD
GREEN BATHOOM _
325 COVE BASE CERAMIC WHITE BOYS E 15.4
TILE BATHOOM
326 WALL PLYWOOD DARK BOYS E < LOD
GREEN BATHOOM
327 WALL PLYWOOD DARK BOYS E < LOD
GREEN BATHOOM
328 FLOOR CERAMIC GRAY BOYS E < LOD
TILE BATHOOM _
329 SPLASHGUA CERAMIC OFF BOYS E 15.7
RD WALL TILE WHITE BATHOOM
330 SPLASHGUA CERAMIC OFF BOYS E 15.2
RD WALL TILE WHITE BATHOOM
331 STALL PLYWOOD OFF BOYS E < LOD
WHITE BATHOOM
332 PIPE CHASE METAL GRAY BOYS E < LOD
DOOR BATHOOM _
333 WINDOW SILL CERAMIE RED 609 E < LOD
ehs/.ii
EHS-International,Inc. 1
L • 0
Limited Hazardous Materials Survey Report
Federal Way High School
• EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Component Substrate Color Room Building Lead Conc.
# (mg/Cm2)
TILE
334 WALL WOOD LIGHT THEATER E 0.04
panels BLUE BREAK RM
335 CABINETS PLYWOOD LIGHT THEATER E 0.25
GREEN BREAK RM
336 COUNTER PLYWOOD BLUE THEATER BK E < LOD
RM DRESSING
337 COUNTER PLYWOOD BLUE THEATER BK E < LOD
RM DRESSING
338 COUNTER PLYWOOD BLUE THEATER BK E < LOD
RM DRESSING
339 COUNTER PLYWOOD BLUE THEATER BK E < LOD
RM DRESSING
340 CABINET PLYWOOD LIGHT 611 F < LOD
GREEN
341 CONDUIT METAL LIGHT 611 F 0.2
COVER TAN
342 DOOR METAL TAN 611 F < LOD
WINDOW
FRAME
343 DOOR METAL TAN 611 F < LOD
WINDOW
FRAME
344 CABINET PLYWOOD LIGHT 611 F 0.05
BLUE
345 WALL GWB TAN 613 F < LOD
346 WALL PLASTER DARK BOYS F < LOD
BROWN RESTROOM
347 WALL PLASTER PEACH BOYS F 0.08
RESTROOM
348 COVE BASE CERAMIC TAN BOYS F 8.9
TILE RESTROOM
349 FLOOR CERAMIC BROWN BOYS F < LOD
TILE RESTROOM
350 STALL PLYWOOD DARK BOYS F < LOD
BLUE RESTROOM
351 RADIATOR METAL OFF BOYS F < LOD
WHITE RESTROOM
352 WALL WOOD OFF 404 F < LOD
PANEL WHITE
353 DOOR FRAME METAL DARK 404 F < LOD
BLUE
354 WALL WOOD DARK HALL F < LOD
GRAY
355 WALL GWB LIGHT OFFICE BTWN F < LOD
BLUE 403&405
356 DOOR FRAME METAL TAN OFFICE BTWN F < LOD
403&405
ehsi4
EHS-International,Inc. 13
S •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Component Substrate Color Room Building
Lead Conc.
# (mg/cm2)
357 DOOR FRAME METAL TAN OFFICE BTWN F < LOD
403&405
358 WALL WOOD LIGHT HALL F < LOD
BLUE
359 RAILING METAL DARK HALL F < LOD
BLUE
360 LOCKER METAL DARK HALL F < LOD
BLUE
361 ELECTRICAL METAL TAN MECH RM F < LOD
PANEL
362 WALL PLASTER TAN MECH RM F < LOD
363 MECH EQUIP METAL BLUE MECH RM F < LOD
364 MECH EQUIP METAL BLUE MECH RM F < LOD
365 WATER METAL YELLOW MECH RM F 0.03
HEATER
366 WALL GWB WHITE HALL F 0.1
367 CEILING WOOD TAN 401 F < LOD
368 CEILING WOOD TAN 401 F < LOD
369 CEILING WOOD TAN 401 F < LOD
370 CALIBRATION N/A RED CALIBRATION CALIBRATIO 1.4
N
371 CALIBRATION N/A RED CALIBRATION CALIBRATIO 0.9
N
372 CALIBRATION N/A RED CALIBRATION CALIBRATIO 0.9
N
373 CALIBRATION N/A RED CALIBRATION CALIBRATIO 1
N
374 CALIBRATION N/A RED CALIBRATION CALIBRATIO < LOD
N
375 CALIBRATION N/A RED CALIBRATION CALIBIRATIO 0.9
N
376 CALIBRATION N/A RED CALIBRATION CALIBRATIO 0.9
N
377 SELF- N/A SELF- SELF- 2.35
CALIBRATION CALIBRATION CALIBRATIO
N
378 CALIBRATION N/A RED CALIBRATION CALIBRATIO 1
N
379 CALIBRATION N/A RED CALIBRATION CALIBRATIO 1
N
380 CALIBRATION N/A RED CALIBRATION CALIBRATIO 0.9
N
381 CALIBRATION N/A RED CALIBRATION CALIBRATIO 1
N
382 WALL GWB TAN 506 G < LOD
etiSi 44I,
EHS-International,Inc.
! 0
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Component Substrate Color Room Building Lead Conc.
# (mg/cm2)
383 WALL BRICK ORANGE 500 BOYS RR G < LOD
384 COVE BASE CERAMIC BURGUN 500 BOYS RR G 0.06
TILE DY
385 COVE BASE CERAMIC BURGUN 500 BOYS RR G 0.04
TILE DY
386 WALL GWB ORANGE 500 BOYS RR G < LOD
387 COVE BASE CERAMIC WHITE 500 BOYS RR G 14.6
TILE
388 WALL BRICK, HOLE ORANGE 500 BOYS RR G < LOD
PTRN
389 WALL BRICK, HOLE ORANGE 500 BOYS RR G < LOD
PTRN
390 FLOOR CERAMIC BROWN 500 BOYS RR G < LOD
TILE
391 STALL PLYWOOD DARK 500 BOYS RR G < LOD
BLUE
392 WALL GWB LIGHT HALL G < LOD
BLUE
393 WINDOW WOOD TAN HALL G < LOD
FRAME
394 WALL GWB LIGHT 500 G < LOD
YELLOW
395 CONDUIT METAL TAN 502 G < LOD
COVER
396 CONDUIT METAL TAN 502 G < LOD
COVER
397 DOOR FRAME METAL TAN 502 G < LOD
398 WALL GWB LIGHT 502 G < LOD
BLUE
399 LOCKERS METAL DARK HALL G < LOD
BLUE
400 PIPE, RAIN METAL TAN 501 STORAGE G < LOD
401 ELECTRICAL METAL TAN JANITOR G < LOD
PANEL CLOSET
402 SPLASHGD CERAMIC PEACH HALL G 12.3
AT DRNK TILE
FTN
403 WALL GWB WHITE 508 G < LOD
404 DOOR METAL TAN 505 G < LOD
WINDOI
FRAME
405 EXTERIOR METAL TAN HALL G < LOD
DOOR
406 EXTERIOR METAL TAN HALL G < LOD
DOOR
407 DOOR FRAME METAL TAN 508 G < LOD
ehsi♦a
EHS-International.Inc. 13
• • ,
Limited Hazardous Materials Survey Report
Federal Way High School ^
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Component Substrate Color Room Building Lead Conc.
)
408 RAILING METAL DARK HALL G < LOD
BLUE
409 WALL GWB TAN JANITOR G < LOD
CLOSET
410 CALIBRATION N/A RED CALIBRATION N/A 0.9
411 CALIBRATION N/A RED CALIBRATION N/A 1
412 CALIBRATION N/A RED CALIBRATION N/A 1
413 CALIBRATION N/A CALIBRATION N/A 2.55
414 CALIBRATION N/A RED CALIBRATION N/A < LOD
415 CALIBRATION N/A RED CALIBRATION N/A < LOD
416 CALIBRATION N/A CALIBRATION N/A 2.47
417 SELF- N/A RED SELF- N/A 1
CALIBRATION CALIBRATION
418 CALIBRATION N/A RED CALIBRATION N/A 1
419 CALIBRATION N/A RED CALIBRATION N/A 1
420 CALIBRATION N/A RED CALIBRATION N/A 1
421 CALIBRATION CERAMIC BLUE CALIBRATION COMUNITY < LOD
POOL
422 WALL CERAMIC WHITE BOYS COMUNITY 9.6
LOCKER POOL
423 COVE BASE CERAMIC WHITE BOYS COMUNITY 8.9
LOCKER POOL
424 SHOWER CERAMIC BROWN BOYS COMUNITY 13.5
STALL LOCKER POOL
425 COLUMN GWB LIGHT POOL AREA COMIJNITY < LOD
YELLOW POOL
426 EXTERIOR METAL BLUE POOL AREA COMUNITY < LOD
DOOR FRAME POOL
427 EXTERIOR METAL BLUE POOL AREA COMIJNITY < LOD
DOOR POOL
428 WALL GWB YELLOW POOL AREA MANAGER < LOD
OFFICE
429 WALL GWB LIGHT OFFICE COMMUNIT 0.05
BLUE Y POOL
430 WALL CERAMIC LIGHT MENS RR COMMUNI 5.7
TILE BROWN TY POOL
431 DOOR METAL BLACK ENTRYWAY COMMUNIT < LOD
Y POOL
432 WINDOW,DO METAL BLACK ENTRYWAY COMMUNIT < LOD
OR FRAME Y POOL
433 SMALL TILE, CERAMIC GRAY POOL AREA COMMUNIT < LOD
POOL Y POOL
PERIMETER
434 FLOOR CERAMIC YELLOW WOMEN COMMUNIT < LOD
LOCKER Y POOL
ehs WS
EHS-International.Inc. 1 3
• i
Limited Hazardous Materials Survey Report
Federal Way High School
' EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Lead Conc.
# Component Substrate Color Room Building (mg/cm2)
435 WALL GWB LIGHT STAFF WOMEN COMMUNIT < LOD
YELLOW LOCKER Y POOL
436 WALL CONCRETE OFF POOL COMMUNIT < LOD
WHITE INTERIOR Y POOL
437 WALL AT CERAMIC OFF POOL COMMUNIT < LOD
FILTER TILE WHITE INTERIOR Y POOL
OPENINGS
438 WALL AT CERAMIC OFF POOL COMMUNI 10.8
FILTER TILE WHITE INTERIOR TY POOL
OPENINGS
439 DIVING METAL BEIGE POOL COMMUNIT < LOD
BOARD Y POOL
SUPPORT
440 AHU METAL LIGHT BOILER RM COMMUNIT 0.13
GREEN Y POOL
441 WALL CONCRETE DARK BOILER RM COMMUNIT < LOD
GRAY OFFICE Y POOL
442 ELECTRICAL METAL GRAY BOILER RM COMMUNIT < LOD
PANEL OFFICE Y POOL
443 WALL BRICK LIGHT BOILER RM COMMUNIT < LOD
YELLOW OFFICE Y POOL
444 BOILER METAL BLACK BOILER RM COMMUNIT < LOD
Y POOL
445 FLOOR CONCRETE LIGHT BOILER RM COMMUNIT 0.04
GRAY Y POOL
446 PIPE, COLD METAL LIGHT BOILER RM COMMUNIT < LOD
WATER GREEN Y POOL
447 HAND RAIL METAL DARK BOILER RM COMMUNIT 0.7
GREEN Y POOL
448 TANK METAL LIGHT BOILER RM COMMUNIT < LOD
GREEN Y POOL
449 TANK METAL LIGHT BOILER RM COMMUNIT < LOD
GREEN Y POOL
450 TANK METAL LIGHT BOILER RM COMMUNIT < LOD
GREEN Y POOL
451 TANK, LOWER CONCRETE LIGHT BOILER RM COMMUNIT 0.05
LEVEL GRAY Y POOL
452 PIPE METAL BLUE BOILER RM COMMUNI 1.4
TY POOL
453 DUCTWORK METAL SILVER BOILER RM COMMUNIT < LOD
Y POOL
454 WALL GWB TAN POOL AREA COMMUNIT < LOD
Y POOL
455 WALL CONCRETE RED EXTERIOR, S COMMUNIT < LOD
Y POOL
456 METAL METAL SILVER EXTERIOR, S COMMUNIT < LOD
COVERED Y POOL
PIPES
ehSla•,
EHS-International,Inc. 13
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Component Substrate Color Room Building Lead Conc.
_ # — (mg/cm2)
457 SIDING BRICK LIGHT EXTERIOR, E COMMUNIT < LOD
BROWN Y POOL
458 FENCE METAL DARK EXTERIOR, N COMMUNIT 0.5
BROWN Y POOL
459 SELF- N/A N/A CALIBRATION N/A 2.46
CALIBRATION
460 CALIBRATION N/A RED CALIBRATION N/A 1
461 CALIBRATION N/A RED CALIBRATION N/A 1
462 CALIBRATION N/A RED CALIBRATION N/A 1
463 CALIBRATION N/A RED CALIBRATION N/A 1
464 WALL PLASTER OFF 407 J < LOD
WHITE
465 DOOR FRAME METAL TAN 407 J < LOD
466 WALL GWB WHITE 407 J < LOD
467 CEILING WOOD BEAM TAN 407 J < LOD
468 CEILING WOOD BEAM TAN 407 J < LOD
469 WINDOW SILL CERAMIC BURGUN 407 J < LOD
TILE DY
470 WALL WOOD GRAY HALL J < LOD
PANEL
471 WALL GWB WHITE HALL J < LOD
472 HAND RAIL METAL DARK HALL J < LOD
BLUE
473 WALL GWB LIGHT 406 J < LOD
BLUE
474 CONDUIT METAL LIGHT 406 J 0.03
COVER BLUE
475 DOOR METAL TAN 406 J < LOD
WINDOW
FRAME
476 WINDOW WOOD TAN 408 J < LOD
TRIM
477 CONDUIT METAL TAN 408 J < LOD
COVER
478 LOCKER METAL DARK HALL J < LOD
BLUE
479 WALL METAL YELLOW 409 J 0.1
480 CEILING SACT WHITE 411 J < LOD
481 WALL PLASTER DARK 410 J 0.05
BLUE
482 WALL GWB DARK 410 J 0.05
RED
483 WALL GWB DARK 410 J 0.09
RED
ehsie,6
EHS-International,Inc. 13
i •
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Component Substrate Color Room Building Lead Conc.
)
484 RAIN PIPE FIBERGLASS TAN JANITOR J 0.08
CLOSET
485 ELECTRICAL METAL TAN HALL J < LOD
PANEL
486 COVE BASE CERAMIC TAN GIRLS 3 8.4
TILE BATHROM
487 FLOOR CERAMIC TAN GIRLS J < LOD
TILE BATHROM
488 STALL WOOD DARK GIRLS J < LOD
BLUE BATHROM
489 RADIATOR METAL TAN GIRLS J 0.04
BATHROM
490 DOOR FRAME METAL TAN STORAGE K < LOD
491 WALL GWB TAN STORAGE K < LOD
492 RADIATOR METAL TAN STORAGE K < LOD
493 PIPE METAL TAN STORAGE K < LOD
494 ELECTRICAL METAL GRAY STORAGE K 0.07
BOX
495 LADDER METAL TAN STORAGE K 0.08
496 CEILING GWB TAN STORAGE K < LOD
497 CEILING GWB TAN STORAGE K < LOD
498 WALL WOOD DARK HALL K < LOD
GRAY
499 HAND RAIL METAL DARK HALL K 0.05
BLUE
500 WALL GWB WHITE HALL K 0.17
501 DOOR FRAME METAL BURGUN 413 K < LOD
DY
502 WALL GWB WHITE 413 K < LOD
503 WALL GWB TEAL 413 K < LOD
504 CONDUIT METAL TEAL 413 K < LOD
COVER
505 CONDUIT METAL TEAL 413 K < LOD
COVER
506 WINDOW SILL CERAMIC BURGUN 413 K < LOD
TILE DY
507 LOCKERS METAL DARK HALL K < LOD
BLUE
508 ACT ON WALL ACT WHITE 415 K < LOD
509 ACT ON WALL ACT WHITE 415 K < LOD
510 ACT ON WALL ACT WHITE 415 K < LOD
511 CEILING SACT WHITE 415 K < LOD
512 WALL GWB TAN 415 K 0.07
ehs14.0
EHS-International,Inc. 13
0 • ,
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Lead Conc.
Component Substrate Color Room Building z
# _ _ (mg/cm )
513 ELECTRICAL METAL TAN 415 K < LOD
PANEL
514 CEILING WOOD LIGHT 417 K < LOD
BLUE
515 CONDUIT METAL LIGHT 417 K < LOD
COVER BLUE
516 WALL GWB LIGHT 417 K < LOD
BLUE
517 WALL GWB YELLOW 416 K < LOD
518 DOOR METAL TAN HALL K < LOD
519 WINDOW METAL TAN HALL K < LOD
FRAME
520 WALL WOOD WHITE HALL K < LOD
521 DOOR METAL DARK HALL H < LOD
BROWN
522 DOOR FRAME METAL DARK HALL H < LOD
BROWN
523 WALL GWB OFF HALL H < LOD
WHITE
524 FIRE METAL OFF HALL H < LOD
EXTINGUISHE WHITE
R CABINET
525 FIRE METAL OFF HALL H < LOD
EXTINGUISHE WHITE
R CABINET
526 DOOR METAL DARK 705 H < LOD
WINDOW BROWN
FRAME
527 FUME HOOD METAL TAN 705 H < LOD
528 WINDOW METAL DARK 705 H < LOD
FRAME BROWN
529 CONDUIT METAL OFF 704 H < LOD
COVER WHITE
530 WINDOW CERAMIC TAN 704 H 15.2
SILL
531 LOCKERS METAL LIGHT HALL H < LOD
BLUE
532 WALL GWB neon 703 H 0.6
green
533 WALL GWB neon 703 H 0.5
green _
534 WALL GWB BLUE 703 H < LOD
535 SINK PLASTER BLACK TEACHER H < LOD
BREAK RM _
536 COVE BASE CERAMIC TAN 706 H < LOD
537 FLOOR CERAMIC TAN- 706 H < LOD
ehs/•)
1
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Component Substrate Color Room Building Lead Conc.
(mg/cm2)
GRAY
538 WALL GWB LIGHT 706 H < LOD
YELLOW
539 ELECTRICAL METAL GRAY HALL H < LOD
PANEL
540 WALL GWB YELLOW GIRLS BATH H < LOD
541 WALL GWB ORANGE BOYS BATH H < LOD
542 DOOR METAL TAN HALL L < LOD
543 DOOR FRAME METAL TAN HALL L < LOD
544WALL CMU WHITE HALL L < LOD
545 WALL CMU WHITE HALL L < LOD
546 WALL WOOD DARK 311 L < LOD
PANEL BLUE
547 WINDOW SILL WOOD OFF 311L < LOD
WHITE
548 WINDOW SILL WOOD OFF 311L < LOD
WHITE
549 WINDOWSILL WOOD OFF 311 L < LOD
WHITE
550 WINDOW SILL WOOD OFF 311 L < LOD
WHITE
551 WINDOW METAL OFF 311 L < LOD
FRAME WHITE
552 DOOR FRAME METAL TAN 312L < LOD
553 DOOR FRAME METAL TAN 312 L < LOD
554 WALL BRICK OFF 312 L < LOD
WHITE
555 PIPE METAL OFF 312 L < LOD
WHITE
556 ELECTRICAL METAL GRAY 312 L < LOD
PANEL
557 COLUMN CONCRETE OFF 312 L < LOD
WHITE
558 FLOOR CONCRETE GRAY 312 L 0.06
559 WALL GWB OFF 312 L < LOD
WHITE
560 LOCKER METAL BLUE 312 L < LOD
561 STAIRS WOOD OFF 312 L 1.1
WHITE
562 CEILING METAL RED 312 L 1.2
563 FLOOR CONCRETE RED 310 L < LOD
564 WALL CMU LIGHT 310 L 0.17
YELLOW
e s
EHS-International,Inc. 13
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527 `
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Lead Conc.
# Component Substrate Color Room Building (mg/cm2
565 LOCKER METAL BLUE 310 L. < LOD
566 WINDOW METAL TAN 310 L. < LOD
FRAME
567 WINDOW METAL TAN 310 L < LOD
FRAME
568 HANDRAIL METAL RED 310 L. < LOD
569 ELECTRICAL METAL GRAY 310 L < LOD
PANEL
570 GARAGE METAL OFF 310 L < LOD
DOOR WHITE
571 LOCKER METAL GRAY 310 L < LOD
572 DISPLAY METAL TAN HALL L < LOD
WINDOW
FRAME
573 DRINKING CERAMIC GRAY HALL L < LOD
FTN
SPLASHGUAR
D
574 FIRE EXT METAL OFF HALL L < LOD
CABINET WHITE
575 DOOR FRAME METAL DARK 308 L < LOD
GRAY
576 WALL CMU BROWN 308 L 0.12
577 WALL CMU LIGHT 308 L 0.3
BLUE
578 CEILING ACT WHITE 308 L 0.4
579 WALL CONCRETE YELLOW 308 L < LOD
580 LOCKER METAL BLUE 308 L < LOD
581 CALIBRATION N/A RED CALIBRATION N/A 1.8
582 CALIBRATION N/A RED CALIBRATION N/A 1
583 CALIBRATION N/A RED CALIBRATION N/A 0.9
584 CALIBRATION N/A RED CALIBRATION N/A 1
585 SELF- N/A SELF- N/A 2.72
CALIBRATION CALIBRATION
586 CALIBRATION N/A RED CALIBRATION N/A 1
587 CALIBRATION N/A RED CALIBRATION N/A 0.9
588 CALIBRATION N/A RED CALIBRATION N/A 0.9
589 WALL GWB TAN 306 M 0.13
INSRUMENT
STORAGE
590 WALL ACT WHITE 306 M < LOD
INSRUMENT
STORAGE
e 5 i 4
14
EHS-International,Inc.
0 •
Limited Hazardous Materials Survey Report
Federal Way High School
' EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Lead Conc.
Component Substrate Color Room Building Z
# (mg/cm2)
591 DOOR FRAME METAL DARK 306 M < LOD
BLUE INSRUMENT
STORAGE
592 DOOR METAL TAN 306 M < LOD
WINDOW INSRUMENT
FRAME STORAGE
593 WALL GWB GREEN 306 PRACTICE M < LOD
RM 2
594 WALL GWB LIGHT 306 M 0.12
BLUE INSTRUMENT
STORAGE
595 DOOR FRAME WOOD TAN 306 DIRECTOR M < LOD
OF BANDS
596 DOOR FRAME METAL TAN HALL M < LOD
597 DOOR FRAME METAL TAN HALL M 0.08
598 DOOR METAL TAN HALL M < LOD
599 DOOR METAL BLACK HALL M < LOD
WINDOW
FRAME
600 WALL BRICK WHITE HALL M < LOD
601 FIRE EXT METAL WHITE HALL M < LOD
CABINET
602 WINDOW METAL WHITE HALL M 0.03
FRAME
603 DOOR TO METAL TAN 305 M < LOD
WINDOW
DISPLAY
604 WALL GWB LIGHT 305 M 0.04
GRAY
605 CONDUIT METAL TAN 305 M < LOD
COVER
606 TRIM, WALL CONCRETE TAN 305 M < LOD
607 WALL CMU LIGHT 305 M 0.14
TAN
608 WALL METAL WHITE HALL M < LOD
609 WALL WOOD LIGHT 307 M < LOD
DISPLAY BLUE
BOARD
610 PIPE METAL TAN 307 M < LOD
611 PIPE METAL TAN 307 M < LOD
612 ELECTRICAL METAL LIGHT 307 M < LOD
PANEL BLUE
613 FLAMMABLES METAL YELLOW 307, M 0.7
STRG CBNT CHEMICAL
STORAGE
ehsi 4
EHS-International,Inc. 14
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Component Substrate Color Room Building Lead Conc.
# (mg/cm )
614 CHEM METAL RED 307, M 0.09
STORAGE CHEMICAL
CABINET STORAGE
615 CORROSIVES METAL DARK 307, NI < LOD
STRG CBNT BLUE CHEMICAL
STORAGE
616 LOCKER METAL DARK HALL M < LOD
BLUE
617 WALL GWB OFF 304 M 0.08
WHITE
618 WALL CONCRETE OFF 304 M 0.15
WHITE
619 WALL TRIM METAL BURGUN 304 M 0.09
DY
620 HAND RAIL METAL TAN 304 N 0.26
621 PIPE METAL TAN MECH RM NI 0.5
622 BOILER METAL BLUE MECH RM NI < LOD
CASING
623 BOILER METAL BLUE MECH RM NI < LOD
CASING
624 DUCT METAL TAN MECH RM NI < LOD
625 ELECTRICAL METAL GRAY MECH RM Ni < LOD
PANEL
626 WALL BRICK TAN MECH RM NI < LOD
627 WALL CMU WHITE HALL Ni < LOD
628 FLOOR CERAMIC PINK GIRLS Ni < LOD
TILE BATHROOM
629 WALL CERAMIC PEACH GIRLS M 15.5
TILE BATHROOM
630 WALL, CERAMIC GRAY HALL M < LOD
DRINKING TILE
FTN SPLASH
631 DRINKING CERAMIC WHITE HALL M 29.1
FTN
632 FLOOR CERAMIC LIGHT BOYS Ni < LOD
BLUE BATHROOM
633 WALL CERAMIC GRAY BOYS M 12
BATHROOM
634 SINK CERAMIC WHITE BOYS M 28.7
BATHROOM
635 STALL METAL LIGHT BOYS NI < LOD
BLUE BATHROOM
636 URINAL METAL WHITE BOYS NI < LOD
BATH ROOM
637 WATER METAL YELLOW STORAGE BY NI 0.03
HEATER BOYS BATH
(' . .s ..
EHS-International,Inc. 14
. . •
410
Limited Hazardous Materials Survey Report
Federal Way High School
' EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Lead Conc.
# Component Substrate Color Room Building (mg/cm2)
638 TOILET CERAMIC WHITE GIRLS M 5.6
BATHROOM
639 TOILET CERAMIC WHITE 500 BOYS G 5.7
BATH
640 SINK CERAMIC WHITE 500 BOYS G 26.8
BATH
641 DRINKING CERAMIC WHITE HALL G < LOD
FTN
642 SINK CERAMIC WHITE MENS BATH F 28
643 URINAL CERAMIC WHITE MENS BATH F 0.03
644 TOILET, WALL CERAMIC WHITE MENS BATH F < LOD
FASTENED
645 DRINKING CERAMIC WHITE HALL L 37
FTN
646 WALL GWB LIGHT 316 N 0.04
YELLOW
647 DOOR WOOD DARK 316 N 0.9
FRAME BLUE
648 DOOR WOOD DARK 316 N 1.4
BLUE
649 WINDOW SILL WOOD TAN 316 N 0.6
650 CEILING WOOD BEAM DARK 316 N < LOD
BLUE
651 WALL WOOD BURGUN 316 N 0.14
DY
652 WINDOW WOOD WHITE 316 N 0.21
FRAME
653 CEILING GWB WHITE 316 N 0.07
654 ELECTRICAL METAL DARK 316 N 0.12
PANEL BLUE
655 CONDUIT METAL LIGHT 316 N < LOD
PIPE COVER YELLOW
656 RADIATOR METAL LIGHT 316 N 0.04
GREEN
657 RADIATOR METAL LIGHT 316 N 0.07
GREEN
658 EXTERIOR WOOD TAN 316 N 1.7
WOOD
SIDING
659 EXT BARRIER CONCRETE BLUE 316 N 0.5
GUARD POLE
660 EXTERIOR WOOD DARK 316 N 2.1
SIDING PURPLE
TRIM
661 EXTERIOR WOOD DARK 316 N 1.8
SIDING PURPLE
TRIM
e st4
EHS-International.Inc. 14
• • . .
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Component Substrate Color Room Building Lead Conc.
# (mg/cm2)
662 EXTERIOR WOOD DARK 316 N 1.7
DOOR PURPLE
663 EXTERIOR WOOD DARK 316 N 0.9
DOOR FRAME PURPLE
664 EXTERIOR WOOD TAN 316 N 0.04
WOOD
PANELS
665 EXTERIOR METAL LIGHT 316 N < LOD
HAND RAIL GRAY
666 EXTERIOR METAL TAN 122 PORTABLE < LOD
DOOR 122
667 EXTERIOR METAL TAN 122 PORTABLE < LOD
DOOR FRAME 122
668 EXTERIOR WOOD TAN 122 PORTABLE < LOD
SIDING 122
669 EXTERIOR WOOD TAN 122 PORTABLE < LOD
ENTRYWAY 122
FLOOR
670 EXTERIOR WOOD DARK 122 PORTABLE < LOD
TRIM BROWN 122
671 EXTERIOR WOOD DARK 122 PORTABLE < LOD
TRIM BROWN 122
672 EXTERIOR WOOD TAN 122 PORTABLE < LOD
WOOD 122
PANELS
673 EXT RAIN METAL WHITE 122 PORTABLE < LOD
PIPE 122
FASTENER
674 EXT RAIN METAL WHITE 122 PORTABLE < LOD
PIPE 122
FASTENER
675 WALL GWB OFF 122 PORTABLE < LOD
WHITE 122
676 DOOR WOOD DARK 122 PORTABLE < LOD
BROWN 122
677 DOOR FRAME WOOD DARK 122 PORTABLE < LOD
BROWN 122
678 WALL PANEL WOOD OFF 122 PORTABLE < LOD
WHITE 122
679 CEILING SACT WHITE 122 PORTABLE < LOD
122
680 CORNER METAL WHITE EXTERIOR M 0.03
GUARD
681 CONCRETE CONCRETE WHITE EXTERIOR M < LOD
PILLAR
682 METAL METAL DARK EXTERIOR M 0.14
SUPPORT BLUE
POLE
ehsi
14
EH$-International,Inc.
s •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Component Substrate Color Room Building Lead Cont.
# (mg/cm2)
683 METAL METAL DARK EXTERIOR M 0.13
SUPPORT BLUE
POLE
684 DOOR METAL DARK EXTERIOR M < LOD
BLUE
685 DOOR FRAME METAL DARK EXTERIOR M 0.05
BLUE
686 FIRE EXT CONCRETE RED EXTERIOR M < LOD
INDICATOR
687 TRANSF CONCRETE YELLOW EXTERIOR M < LOD
BARRIER
POLE
688 TRANSFORME PLASTER LIGHT EXTERIOR M 0.06
R CABINET GREEN
689 DOOR METAL LIGHT EXTERIOR L < LOD
GRAY
690 DOOR FRAME METAL LIGHT EXTERIOR L < LOD
GRAY
691 DOOR FRAME METAL LIGHT EXTERIOR L < LOD
GRAY
692 GARAGE CONCRETE LIGHT EXTERIOR L 0.05
DOOR FRAME GRAY
693 GARAGE CONCRETE LIGHT EXTERIOR L 0.04
DOOR FRAME GRAY
694 GARAGE METAL LIGHT EXTERIOR L < LOD
DOOR GRAY
695 BARRIER CONCRETE YELLOW EXTERIOR L 3.1
GUARD
696 SIDING BRICK BROWN EXTERIOR L < LOD
697 SIDING CMU BROWN EXTERIOR L < LOD
698 GARAGE WOOD WHITE EXTERIOR L < LOD
DOOR FRAME
699 SIDING BRICK WHITE EXTERIOR L < LOD
700 SIDING CMU WHITE EXTERIOR L < LOD
701 SIDING CMU TAN EXTERIOR L < LOD
702 SIDING TRIM WOOD TAN EXTERIOR F < LOD
703 PARK LOT METAL YELLOW EXTERIOR F 0.5
ENTRY GATE
704 FIRE CONCRETE YELLOW EXTERIOR F < LOD
HYDRANT
705 OVERHANG METAL BEIGE EXTERIOR H < LOD
SUPPORT
706 OVERHANG METAL BEIGE EXTERIOR H < LOD
SUPPORT
707 RAIN PIPE METAL BEIGE EXTERIOR H < LOD
708 DOOR METAL BEIGE EXTERIOR H < LOD
ehsi 4
EHS-International,Inc. 14
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Lead Conc.
# Component Substrate Color Room Building (mg/cm2)
709 DOOR FRAME METAL BEIGE EXTERIOR H < LOD
710 SIDING CONCRETE OFF EXTERIOR G < LOD
WHITE
711 HAND RAILS METAL DARK EXTERIOR G < LOD
BLUE
712 PERIMETER CONCRETE OFF EXTERIOR E < LOD
FOUNDATION WHITE _
713 RAIN PIPE METAL BROWN EXTERIOR E 0.4
714 SIDING CONCRETE LIGHT EXTERIOR E < LOD
GRAY
715 SIDING CONCRETE OFF EXTERIOR A2 < LOD
WHITE
716 SIDING CONCRETE OFF EXTERIOR A2 < LOD
WHITE
717 OVERHANG METAL GRAY EXTERIOR C 0.9
SUPPORT
718 WALKWAY CONCRETE OFF EXTERIOR C < LOD
COLUMNS WHITE
719 CALIBRATION N/A RED CALIBRATION N/A < LOD
720 CALIBRATION N/A RED CALIBRATION N/A 1.2
721 CALIBRATION N/A RED CALIBRATION N/A 0.9
722 CALIBRATION N/A RED CALIBRATION N/A 1
723 CALIBRATION N/A RED CALIBRATION N/A 1
724 SELF- N/A N/A SELF- N/A 2.64
CALIBRATION CALIBRATION
725 CALIBRATION N/A RED CALIBRATION N/A 1
726 CALIBRATION N/A RED CALIBRATION N/A 0.9
727 CALIBRATION N/A RED CALIBRATION N/A 1
728 CALIBRATION N/A RED CALIBRATION N/A 1
729 CALIBRATION N/A RED CALIBRATION N/A 1
730 CALIBRATION N/A RED CALIBRATION N/A 1
731 CALIBRATION N/A RED CALIBRATION N/A 1
732 CALIBRATION N/A RED CALIBRATION N/A 1
733 SIDING STUCCO WHITE EXTERIOR, S :I 1.2
734 WALKWAY METAL WHITE EXTERIOR BETWEEN J < LOD
COVER AND H
SUPPORT
735 PICNIC TABLE WOOD DARK EXTERIOR BETWEEN F < LOD
BLUE AND G
736 SHED WOOD TAN EXTERIOR F < LOD
737 SHED DOOR WOOD DARK EXTERIOR F < LOD
BLUE
ehSi..
EHS-International,Inc. 14
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Lead Conc.
# Component Substrate Color Room Building (mg/cm2)
738 LOWER CONCRETE WHITE EXTERIOR HALL < LOD
SIDING BETWEEN
F&G
739 LOWER CONCRETE WHITE EXTERIOR HALL 1.3
SIDING BETWEEN
F&G
740 WINDOW SILL METAL DARK EXTERIOR HALL < LOD
BROWN BETWEEN
F&G
741 WINDOW METAL DARK EXTERIOR HALL < LOD
FRAME BROWN BETWEEN
F&G
742 SIDING STUCCO WHITE EXTERIOR, N E 1.3
743 SITTING WOOD REDDISH EXTERIOR, E < LOD
BENCH BROWN COURTYARD
744 CEILING METAL OFF EXT, COVERED D < LOD
WHITE WALKWAY
745 CEILING METAL OFF EXT, COVERED D < LOD
WHITE WALKWAY
746 CEILING METAL OFF EXT, COVERED D 0.07
WHITE WALKWAY
747 HAND RAIL METAL PURPLE EXTERIOR, W D 0.09
748 SUPPORT WOOD OFF EXT, W D < LOD
BEAM,CEILIN WHITE COVERED
G WALKWY
749 SUPPORT WOOD OFF EXT, W D < LOD
BEAM,CEILIN WHITE COVERED
G WALKWY
750 TILT UP CONCRETE OFF EXTERIOR, L < LOD
SIDING WHITE EAST
751 WELL, LAWN WOOD WHITE EXTERIOR, M < LOD
DECORATION SOUTH
752 PIPE METAL GRAY EXTERIOR, C < LOD
WEST
753 SIDING CONCRETE OFF EXTERIOR, C < LOD
WHITE WEST
754 SIDING CONCRETE OFF EXTERIOR, C < LOD
WHITE WEST
755 SIDING CONCRETE OFF EXTERIOR, C 1.4
WHITE WEST
756 SIDING, CONCRETE DARK EXTERIOR, C < LOD
LOWER BLUE WEST
PERIMETER
757 SIDING, CONCRETE DARK EXTERIOR, C < LOD
LOWER BLUE WEST
PERIMETER
758 PICNIC TABLE METAL ARMY EXTERIOR, C < LOD
GREEN WEST
e si4
EHS-International,Inc. 14
• • t
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
FEDERAL WAY HIGH SCHOOL
Read. Lead Conc.
# Component Substrate Color Room Building (mg/cm2)
759 PICNIC TABLE METAL ARMY EXTERIOR, C; < LOD
GREEN WEST
760 HAND RAILS METAL DARK EXTERIOR BETWEEN 1.4
GRAY B AND M
761 HAND RAILS METAL DARK EXTERIOR BETWEEN B < LOD
GRAY AND M
762 HAND RAILS METAL DARK EXTERIOR BETWEEN B 1
GRAY AND M
763 HAND RAILS METAL DARK EXTERIOR BETWEEN B 1
GRAY AND M
764 CALIBRATION N/A RED CALIBRATION N/A 1
765 CALIBRATION N/A RED CALIBRATION N/A 1
766 CALIBRATION N/A RED CALIBRATION N/A 1
Key: LOD=Limit of Detection
Table 4 summarizes bulk QA lead samples, including sample number, material description,
substrate, color, location, and analytical results.
Copies of the analytical laboratory report and field data forms for lead paint are included in
Appendix B of this report.
TABLE 4
SUMMARY OF LEAD BULK QA SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE RESULTS
NUMBER LOCATION COMPONENT SUBSTRATE COLOR % Pb by
WT
Block Al Auxiliary Wall Concrete Beige 0.0075
10527-L01 Gym (XRF #5)
Block A2 Boys Locker Wall CMU Gray 0.0074
10527-L02 Room (XRF #19) .
Block A2 Boys Locker
Room Staff Restroom Floor Concrete Beige <0.0036
10527-L03 (XRF #41)
Block A2 Boys Locker
Room Staff Restroom Wall Concrete White/White 0.0310
10527-L04 (XRF #42)
Block B Cafeteria Wood Column Wood Blue on Red 0.4000
10527-L05 (XRF #89)
Block B Kitchen Wall CMU White 0.0390
10527-L06 Restroom (XRF #107)
Block B Cafeteria File Wall GWB White <0.0045
10527-L07 Room (XRF # )
ehsi�e
EHS-International,Inc. 14
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 4
SUMMARY OF LEAD BULK QA SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE RESULTS
NUMBER LOCATION COMPONENT SUBSTRATE COLOR % Pb by
WT
Block C 1st Floor Girls Stall Wall Metal Light Green 1.2000
10527-L08 Restroom (XRF #183)
Block C 1st Floor Off-
Men's Restroom (XRF Wall GWB 0.0180
White/Beige
10527-L09 #184)
Block C 1st Floor Fire
Alarm Closet (XRF Wall CMU Beige <0.0045
10527-L10 #187)
Block C 1st Floor
Boiler Room (XRF Wall Brick Beige 0.0044
10527-L11 #215)
Block D Library (XRF Wall GWB Beige/White <0.0044
10527-L12 #238)
Block D Room 113 Wall Brick Blue <0.0035
10527-L13 (XRF #265)
Block E Hall (XRF Wall GWB White <0.0044
10527-L14 #281)
Block E Room 121 Wall GWB Blue <0.0044
10527-L15 (XRF #287)
Block E Room 602 Wall GWB Neon Green 0.0720
10527-L16 (XRF #297)
Block F Office
Between Room Door Frame Metal Tan <0.0110
10527-L17 403&405 (XRF #357)
Block F Hall (XRF Wall Wood Blue <0.0045
10527-L18 #358)
Block F Mechanical Wall Plaster Tan <0.0048
10527-L19 Room (XRF #362)
Block G Room 506 Wall GWB Tan <0.0048
10527-L20 (XRF #382)
Block G Boys Cove base Ceramic Tile White 0.0140
10527-L21 Restroom (XRF #387)
Block G Janitor (XRF Wall GWB Tan <0.0052
10527-L22 #409)
Community Pool
Men's Locker Room Wall Ceramic Tile Blue <0.0045
10527-L23 (XRF #421)
Community Pool
Men's Locker Room Wall Ceramic Tile Off-White <0.0040
10527-L24 (XRF #422)
Block J Room 407 Wall GWB White <0.0140
10527-L25 (XRF #466)
14
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 4
SUMMARY OF LEAD BULK QA SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE RESULTS
NUMBER LOCATION COMPONENT SUBSTRATE COLOR % Pb by
WT
Block J Room 406 Wall GWB Light Blue <0.0048
10527-L26 (XRF #473)
Block K Room 415 Wall GWB Tan 0.0390
10527-L27 (XRF #512)
Block K Hall (XRF Wall GWB White <0.0120
10527-L28 #520)
Block H Hall (XRF Wall GWB Off-White <0.0055
10527-L29 #523)
Block H Room 706 Cove Base Ceramic Tan <0.0043
10527-L30 (XRF #536)
Block L Room 311 Window Sill Wood Off-White <0.0045
10527-L31 (XRF #550)
Block L Room 312 Stairs Wood Off-White <0.0130
10527-L32 (XRF #561)
Block M Instrument Wall ACT White <0.0061
10527-L33 Storage (XRF #590)
Block M Hall (XRF Wall Brick White <0.0046
10527-L34 #600)
Portable 1 Exterior Siding Wood Tan 0.0130
10527-L35 (XRF #664)
Portable 2 Ceiling Ceiling SACT White <0.0048
10527-L36 (XRF #679)
Block M Exterior (XRF Pillar Concrete White 0.0150
10527-L37 #681)
Block L Exterior (XRF Barrier Guard Concrete Yellow 4.6000
10527-L38 #695)
Block E Exterior (XRF Siding Stucco White <0.0039
10527-L39 #742)
Block C Exterior (XRF Siding Concrete White 0.0490
10527-L40 #755)
Key: ACT= Acoustic Ceiling Tile, CMU=Concrete Masonry Unit, GWB=Gypsum Wallboard,
SACT = Suspended Acoustic Ceiling Tile, QA=Quality Assurance Bulk Sample submitted for
analysis
DOSH requires employers to conduct a hazard assessment and take appropriate worker
protection precautions whenever paint is disturbed that has detectable quantities of lead.
Since the type of work planned (e.g., sawing, grinding, demolition) will disturb the lead-
containing paint, the contractor should perform an initial exposure assessment to determine if
personal protective measures and work practices are required. With concentrations of lead in
paint ranging from 9.4 mg Pb/cm2 to <LOD and 4.5 wt% PB to <LOD, and concentrations of
lead in LCM ranging from 37 mg Pb/cm2 to <LOD, it is possible that the planned work (e.g.,
demolition) could result in lead exposures above the DOSH action level of 30 milligram per
cubic meter (mg/m3). For work on those materials with high lead concentrations as shown in
15
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
Tables 3 & 4, EHSI recommends the Contractor provided worker protection until exposure
monitoring is accomplished.
2.4.3 Arsenic-Containing Building Materials
EHSI also collected ten (10) Arsenic bulk mortar samples for laboratory analysis. The results
of those analyses are reported in Table 5.
Arsenic results for this inspection are reported in Appendix B. Table 5 summarizes Arsenic
samples, including sample number, material description, substrate, color and analytical
results.
TABLE 5
SUMMARY OF ARSENIC BULK SAMPLING AND ANALYTICAL RESULTS
FEDERAL WAY HIGH SCHOOL
SAMPLE SAMPLE LOCATION COMPONENT/ COLOR RESULTS
NUMBER SUBSTRATE IN PPM
10527-As-01 Community Pool-Interior Pool Brick and Brick Red/Gray <13.0
Area, south Mortar
10527-Ar-02 Community Pool-Exterior, NW Brick and Brick Red/Gray <14.0
Corner Mortar
10527-As-03 Federal Way High School, Brick and Brick Red/Gray <13.0
Block M-Exterior Mortar
10527-As-04 Federal Way High School, CMU and CMU Gray/Gray <13.0
Block L- Exterior Mortar
Federal Way High School, CMU and CMU Gray/Gray-
10527-As-05 Block A-Interior Mortar Black <17.0
10527-As-06 Federal Way High School, Brick and Brick Red/Tan <18.0
Block C-Exterior Mortar
10527-As-07 Federal Way High School, Stone Block and Red/Gray <13.0
Block E-Exterior Mortar
10527-As-08 Federal Way High School, Brick and Brick Red/Gray <17.0
Block F-Exterior Mortar
10527-As-09 Federal Way High School, CMU and CMU Gray/Gray <16.0
Block M-Interior Mortar
10527-As-10 Federal Way High School, Brick and Brick Red/Pink <17.0
Block L-Exterior Mortar
DOSH requires employers to conduct a hazard assessment and take appropriate worker
protection precautions whenever arsenic-containing materials are disturbed. Based on the
absence of arsenic identified in the sample results, EHSI does not anticipate arsenic exposures
above the DOSH permissible exposure limit of 0.2 mg/m3 within an 8 hour time period.
2.4.4 Toxic Characteristic Leaching Procedure Sampling
Ecology requires testing using the "toxic characteristic leachate procedure" (TCLP) and
segregation of construction debris if it is potentially contaminated with dangerous waste
(e.g., lead-containing paint/lead-containing materials and arsenic-containing brick mortar).
Washington State Department of Ecology (Ecology) has set a dangerous waste threshold for
both leachable arsenic and lead at 5.0 milligrams per liter (mg/L).
ehsi.)
15
EHS-International,Inc.
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
Because the potential waste streams will be determined by the contractor, a TCLP was not
conducted as part of the Limited Hazardous Materials Survey; however, based on the
relatively low levels of lead and the absence of arsenic identified in the sample results, EHSI
does not anticipate TCLP to fail for either arsenic or lead. If, however, the ceramic wall tiles
and/or porcelain fixtures with high lead content are placed in a separate waste stream other
than general construction debris, there is a strong possibility the TCLP for those waste
streams may fail for high leachable lead concentrations.
2.4.5 Polychlorinated Biphenyls
Ballasts
EHSI inspected a representative number of each type of fluorescent fixture expected to be
disturbed by the planned work for PCB-containing ballasts. The majority of the fixtures
were found to contain electronic ballasts, which contain no dielectric fluid and may be
disposed as construction debris. A few fixtures were found to contain magnetic ballasts and
must be disposed/recycled as Ecology Dangerous Waste. A Summary of ballasts and Hg-
containing light tubes is provided in Table 6.
Transformers
EHSI contacted Puget Sound Energy, and Engineer Annette Wilson. She stated that the
transformers at Federal Way High School have already been changed out to contain PCB-
free oil.
2.4.6 Mercury-Containing Fluorescent Light Tubes
All fluorescent light tubes quantified in Table 6 are assumed to contain Hg. Hg wastes are
regulated as "universal wastes" under Ecology's regulation WAC 173-303. Hg-containing
building materials must be recycled or disposed of as hazardous waste. Hg-containing
fluorescent light tubes are quantified in Table 6.
TABLE 6
SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS
FEDERAL WAY HIGH SCHOOL
NUMBER APPROXIMATE
LIGHT TYPE OF NUMBER NUMBER OF
FIXTURE OF TUBES MAGNETIC
S BALLASTS
Block A
Mounted 2'x4' Fixture w/ 6 bulbs and 2 32 192 64
PCB Magnetic Ballasts
Mounted l'x4' Fixture w/ 2 bulbs and 1 12 24 12
PCB magnetic ballast
Mounted l'x4' Fixture w/ 3 bulbs and 1 10 30 10
PCB magnetic ballast
Recessed 2'x4' Fixture w/ 3 bulbs and 1 36 108 36
PCB magnetic Ballast
ENS-International,Inc. 15
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 6
SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS
FEDERAL WAY HIGH SCHOOL
NUMBER APPROXIMATE
LIGHT TYPE OF NUMBER NUMBER OF
FIXTURE OF TUBES MAGNETIC
S BALLASTS
Wall Mounted 1'x4' Fixture w/ 2 blubs 19 38 19
and 1 PCB magnetic ballast
Mounted 6"x4' Fixture w/ 2 bulbs and 1 161 322 161
PCB magnetic ballast
Hanging 2'x4' Fixture w/ 6 bulbs and 2 15 90 30
PCB magnetic ballast
Hanging/Mounted Circle shaped fixture 6 6 0
w/ 1 bulb
Block A Total 291 810 332
Block B
Recessed 4'x4' Fixture w/ 6 bulbs and 2 30 180 60
PCB magnetic ballasts
Recessed 2'x4' Fixture w/ 3 bulbs and 2 53 159 106
PCB magnetic ballasts
6"x4" Mounted, grill cover fixture w/ 2 1 2 1
bulbs and 1 PCB magnetic ballast
l'x4' Mounted fixture w/ 2 bulbs and 1 2 4 2
PCB magnetic ballast
6"x4' Mounted, snap cover fixture w/ 2 12 24 12
bulbs and 1 PCB magnetic ballast
1'x4' Mounted, swing cover fixture w/ 2 6 12 6
bulbs and 1 PCB magnetic ballast
Block B Total 104 381 187
Block C
2'x4' Recessed Fixture w/ 3 bulbs and 2 292 876 584
Magnetic, PCB ballasts
1'x4' Wall/Ceiling mounted fixture w/ 2 16 32 16
bulbs and 1 Magnetic PCB ballast
1'x4' Mounted Fixture w/ 2 bulbs and 1 14 28 14
Magnetic PCB ballast
6"x4" Mounted, grill cover fixture w/ 2 19 38 19
bulbs and 1 PCB magnetic ballast
Block C Totals 341 974 633
Block D
2'x4' Recessed Fixture w/ 4 bulbs and 2 145 580 290
Magnetic, PCB ballasts
6"x4" Mounted, grill cover fixture w/ 2 9 18 9
bulbs and 1 PCB magnetic ballast
l'x4' Mounted, swing cover fixture w/ 2 24 48 24
bulbs and 1 PCB magnetic ballast
ehsi
ENS-International,Inc. 15
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 6
SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS
FEDERAL WAY HIGH SCHOOL
NUMBER APPROXIMATE
LIGHT TYPE OF NUMBER NUMBER OF
FIXTURE OF TUBES MAGNETIC
S BALLASTS
1'x4' Mounted Fixture w/ 2 bulbs and 1 16 32 16
Magnetic PCB ballast
4'x4' Mounted Fixture w/8 bulbs and 2 55 440 110
Magnetic PCB ballast
Block D Totals 249 1,118 449
Block E
2'x4' Recessed Fixture w/ 3 bulbs and 2 78 234 156
Magnetic, PCB ballasts
1'x4' Wall/Ceiling mounted fixture w/ 2 3 6 3
bulbs and 1 Magnetic PCB ballast
6"x4" Mounted, grill cover fixture w/ 2 9 18 9
bulbs and 1 PCB magnetic ballast
Block E Totals 90 258 168
Block F
2'x4' Recessed Fixture w/ 4 bulbs and 2 213 852 426
Magnetic, PCB ballasts
l'x4' Wall/Ceiling mounted fixture w/ 2 1 2 1
bulbs and 1 Magnetic PCB ballast
1'x4' Mounted Fixture w/ 2 bulbs and 1 11 22 11
Magnetic PCB ballast
6"x4" Mounted, grill cover fixture w/ 2 6 12 12
bulbs and 1 PCB magnetic ballast
Block F Totals 231 888 450
Block G
2'x4' Recessed Fixture w/ 4 bulbs and 2 85 340 170
Magnetic, PCB ballasts
1'x4' Wall/Ceiling mounted fixture w/ 2 10 20 10
bulbs and 1 Magnetic PCB ballast
1'x4' Mounted Fixture w/ 2 bulbs and 1 6 12 6
Magnetic PCB ballast
6"x4" Mounted, grill cover fixture w/ 2 3 6 3
bulbs and 1 PCB magnetic ballast
Block G Totals 115 400 200
Block H
2'x4' Recessed Fixture w/ 4 bulbs and 2 62 248 124
Magnetic, PCB ballasts
1'x4' Wall/Ceiling mounted fixture w/ 2 11 22 11
bulbs and 1 Magnetic PCB ballast
l'x4' Mounted Fixture w/ 2 bulbs and 1 6 12 6
Magnetic PCB ballast
6"x4" Mounted, grill cover fixture w/ 2 1 2 1
bulbs and 1 PCB magnetic ballast
ehsi
EHS-International,Inc. 15
• •
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 6
SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS
FEDERAL WAY HIGH SCHOOL
NUMBER APPROXIMATE
LIGHT TYPE OF NUMBER NUMBER OF
FIXTURE OF TUBES MAGNETIC
S BALLASTS
Block H Totals 80 284 142
Block 7
2'x4' Recessed Fixture w/ 4 bulbs and 2 105 420 210
Magnetic, PCB ballasts
1'x4' Wall/Ceiling mounted fixture w/ 2 10 20 10
bulbs and 1 Magnetic PCB ballast
l'x4' Mounted Fixture w/ 2 bulbs and 1 8 16 8
Magnetic PCB ballast
6"x4" Mounted, grill cover fixture w/ 2 4 8 4
bulbs and 1 PCB magnetic ballast
Block ] Totals 127 464 232
Block K
2'x4' Recessed Fixture w/ 4 bulbs and 2 103 412 206
Magnetic, PCB ballasts
l'x4' Mounted Fixture w/ 2 bulbs and 1 2 4 2
Magnetic PCB ballast
Block K Totals 105 416 208
Block L
2'x4' Recessed Fixture w/ 4 bulbs and 2 256
Magnetic, PCB ballasts 64 128
2'x4' Suspended Fixture w/ 4 bulbs and 24 96 48
2 Magnetic, PCB ballast
l'x8' Mounted Fixture w/ 2 bulbs and 1 18 36 18
Magnetic, PCB Ballast
l'x4' Mounted, swing cover fixture w/ 3 3 9 6
bulbs and 2 Magnetic PCB ballast
6"x4" Mounted, grill cover fixture w/ 2 3 6 3
bulbs and 1 PCB magnetic ballast
6"x4' Suspended Fixture w/ 2 bulbs and 91 182 92
1 Magnetic PCB ballast
Block L Totals 203 585 295
Block M
2'x4' Recessed Fixture w/ 4 bulbs and 2 176 704 352
Magnetic, PCB ballasts
l'x8' Mounted Fixture w/ 2 bulbs and 1 25 50 25
Magnetic, PCB Ballast
1'x4' Mounted, swing cover fixture w/ 3 49 147 98
bulbs and 2 Magnetic PCB ballast
6"x4" Mounted, grill cover fixture w/ 2 12 24 12
bulbs and 1 PCB magnetic ballast
ehSial.. 15
EHS-International,Inc.
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
TABLE 6
SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS
FEDERAL WAY HIGH SCHOOL
NUMBER APPROXIMATE
LIGHT TYPE OF NUMBER NUMBER OF
FIXTURE OF TUBES MAGNETIC
S BALLASTS
1'x4' Wall/Ceiling mounted fixture w/ 2 5 10 5
bulbs and 1 Magnetic PCB ballast
Block M Totals 267 935 492
Covered Walkways
1'x4' Mounted Fixture w/ 2 bulbs and 1 9 18 9
magnetic ballast
Covered Walkway Total 9 18 9
P1
6"x4' Mounted, fixture w/ 2 bulbs and 2 14 42 28
Magnetic PCB ballast
P1 Totals 14 42 28
P2
2''x4' Recessed Fixture w/ 4 bulbs and 2 48 192 96
Magnetic, PCB ballasts
P2 Totals 48 192 96
Community Pool
l'x4' Mounted, swing cover fixture w/ 2 35 70 35
bulbs and 1 Magnetic PCB ballast
1'x4' Mounted, swing cover fixture w/ 4 1 2 2
bulbs and 2 Magnetic PCB ballast
1 Circular Fixture w/ 1 bulb and 1 PCB 20 20 20
Magnetic ballast
Square recessed fixture w/ 1 round bulb 8 8 8
HID floodlight 1 1 1
Community Pool Totals 65 101 66
3.0 LIMITATIONS
This survey was limited to those materials accessible using standard survey methods.
Limited representative destructive inspection was accomplished; however, in areas
inaccessible for inspection, (e.g., fire door cores) suspect materials were assumed to be
ACM.
This survey was limited to the chemicals and materials identified herein. No effort was
made to identify hazardous materials in soil, water, or air, other than those listed herein.
Any survey regardless of how extensive can miss concealed materials. Contractors should
be aware of the potential that demolition activities may expose concealed suspect ACM and
should have preplanned contingencies for handling these materials when discovered during
eh•Si.)
15
ENS-International,Inc.
•
Limited Hazardous Materials Survey Report
Federal Way High School
EHSI Project 10527
July 12, 2013
demolition work. Any concealed, suspect ACM material that was not sampled or that was
assumed to be ACM by this survey report when encountered must be treated as ACM until
sampled by a Certified AHERA Building Inspector and analyzed by a certified laboratory.
4.o STANDARD OF CARE
The recommendations and conclusions contained in this report represent the professional
opinions of EHSI. These opinions are derived in accordance with federal, state, and local
environmental and health and safety laws and regulations. This survey was accomplished in
accordance with applicable federal, state, and local regulations and industry standards in
effect at the time. Other than this, no other warranty is implied or intended.
5.o CERTIFIED AHERA BUILDING INSPECTORS
The Certified AHERA Building Inspectors listed below surveyed Federal Way High School on
April 1St-19th and June 25th, 2013, in accordance with federal, state, and local requirements.
Brett Racine Rory Peterson
Certified AHERA Building Inspector Certified AHERA Building Inspector
Certificate Number: 10484-02-03 Certificate Number 10484-02-02
Expiration Date: January 03, 2014 Expiration Date: January 03, 2014
Nadir Khan Lisa Kollasch
Certified AHERA Building Inspector Certified AHERA Building Inspector
Certificate Number: 10484-02-04 Certificate Number 10484-02-09
Expiration Date: January 03, 2014 Expiration Date: January 03, 2014
ehsi15
•
APPENDIX A
Asbestos Analytical Laboratory Report
and Field Data Forms
ehsiJ
EHS-International,Inc. Appendix A
III •
SEAT'' E ASBESTOS TEST
Lynnwood Laboratory 19701 Salyer Lake Road,Sule 103, Be9e.ue Laboratory 12727 Northup Way,Sate 1,Bellevue. Seattle Labcescmy 4503 9th Ave_`tE.yule 306.Searle.WA 98105
Lynnwood.WA 98036,Td:425.673.9850.Far 425.673.9810 WA 98098,Tel'425.861_1111,Fax:425.861.1118 Tel:206.6311111,F .206.633.4747
ANALYTICAL LABORATORY REPORT
PIM by Method EPA/600/R-931116
Arm.: Mr.Herb Brod calm EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005
Job/: 10527-01r Bee* 201310460 Dace Received. 4/3/2013
Samples Recd 110 Dela Analysed: 4/9/2013 Samples Mal zee 110
PralectLoc. Federal Way High School-Block
CCt
A
Analyzed by: Liz Dutoniklary Srdnrans ReNewed by Steve(Farryaoi/hang,President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fiixous
Components % Non-asbestos Fibers
1 Beige/gray rubbery None Rubber/binder 2 Cellulose
material detected
one
1 10527-A-01 2 Tan mastic ae tected Mastic/binder 3 Cellulose
None
3 White/beige paintetedPaint/binder 2 Cellulose
dect
1 Gray soft/elastic None Binder, Filler, Paint 4 Cellulose
2 10527-A-02 material with paint detected
2 Yellow foamy None Synthetic foam None detected
material detected
1 White brittle None Binder/filler, Paint, 5 Cellulose
3 10527-A-03 material with paint detected Sands
2 White chalky None Binder/filler, Cellulose,
material with paper detected Gypsum/binder 26 Glass Fibers
1 White brittle None Binder/filler, Paint, 6 Cellulose
4 10527-A-04 material with paint detected Sands
2 White chalky None Binder/filler, Cellulose,
material with paper detected Gypsum/binder 24 Glass Fibers
1 White brittle None Binder/filler, Paint, 7 Cellulose
5 10527-A-05 material with paint detected Sands
2 White chalky None Binder/filler, Cellulose,
material with paper detected Gypsum/binder 25 Glass Fibers
1 Gray fibrous None Paint, Filler, Glass Glass fibers,
6 10527-A-06 material with paint detected beads 66 Cellulose
None
2 Brown mastic Mastic/binder 5 Cellulose,
White powdery
1 material with None Binder/filler 27 Cellulose,
7 10527-A-07 woven fibrous detected Glass fibers
material
2 White chalky None Binder/filler, 23 Cellulose,
material with paper detected Gypsum/binder Glass Fibers
8 10527-A-08 1 Tan soft material None Filler, Binder 5 Cellulose,
detected Wollastonite
1 Off-white tile None Vinyl/binder, 3 Cellulose
detected Mineral grains
9 10527-A-09 2 Yellow mastic deed Mastic/binder 4 Cellulose
Gray None
3 mater alttie d Filler, Binder 2 Cellulose
1 White brittle None Binder/filler, Paint, 5 Cellulose
10 10527-A-10 material with paint detected Sands
2 White chalky None Binder/filler, Cellulose..
material with paper detected Gypsum/binder 29 Glass Fibers
1 White brittle None Binder/filler, Paint, 5 Cellulose
11 10527-A-11 material with paint detected Sands
2 White chalky None Binder/filler, 29 Cellulose.
material with paper detected Gypsum/binder Glass Fibers
12 10527-A-12 1 White brittle None Binder/filler, Paint, 5 Cellulose
material with paint detected Sands
1
• •
SEATTLE ASBESTOS TEST NVLAP Accreditation Lab e-276,Lynnwood-20e
Lynnwood Laboratory 19701 Scriber Lake Road,Suite 103, Bellevue Laboratory 12727 Nortlup Way,Suite 1,Belevue, Seattle Laboratory 4500 9th Ave NE,State 300.Seattle,WA 96105 •
Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tet 425.861.1111,Fax 425.861.1118 Tel:206.633.1111,Fax 206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/R-93/116
Ami.: Mr.Herb Brod csent EHS International,Inc. mere= 13228 NE 20th St#100,Bellevue.WA 98005
,lob#: 10527-01r Batdgr: 201310460 Data Received: 413/2013
samples Recd: 110 Date Analyzed: 4/9/2013 SamWee Analyzed: 110
Federal Way High School-Block r���
Project Loc.: A
Analyzed by: Liz Dutton/Mary Eiomann Renewed by: Steve(Fanyaol Zhang.President
Lab ID Client Sample ID Layer Description % Asbestos Febers Non-fibrous Components % Non-asbestos Fibers
White chalky None Binder/filler, Cellulose,
2 material with paper detected Gypsum/binder 29 Glass Fibers
1 Black rubbery None Rubber/binder 2 Cellulose
material detected
13 10527-A-13 2 Cream mastic Ndetected Mastic/binder 3 Cellulose
Non3 White paintPaint/binderPaint/binder 2 Cellulose
1 Blue woven fibrous None Filler, Binder 85 Synthetic fibers
material detected
Gray None
14 10527-A-14 2 material foamy detected Synthetic foam None detected
e
• 3 Yellow mastic Betted Mastic/binder 3 Cellulose
White soft material None Filler, Binder, Foil,
1 with silver foil and detected Mastic/binder 2 Cellulose
15 10527-A-15 mastic
Gray fibrous None Cellulose,
2 material detected Filler, Glass beads 69 Glass fibers
1 Orange/brown None Ceramic/binder None detected
ceramic detected
16 10527-A-16 2 Gray sandy/brittle None Binder, Sand 2 Cellulose
material detected _
3 Gray brittle/sandy None Filler, Binder 2 Cellulose
material detected
1
Orange/brown None Ceramic/binder None detected
ceramic detected _
2 Gray sandy/brittle None Binder, Sand 2 Cellulose
17 10527-A-17 material detected
Black/dark gray
3 brittle/sandy d onetected Filler, Binder 3 Cellulose
material
Black soft material None Filler,
18 10527-A-18 1 with white paint detected Asphalt/Binder, 5 Cellulose
Paint
1 Beige paint None Paint 2 Cellulose
detected
19 10527-A-19 2 White brittle None Filler, Binder 4 Cellulose
material detected
3 Gray sandy brittle None Sand, Filler, Binder 6 Cellulose
material detected
1 Beige paint
None
Paint 3 Cellulose
20 10527-A-20 2 White brittle None Filler, Binder 3 Cellulose
material detected
3 Gray sandy/brittle None Sand, Filler, Binder 5 Cellulose
material detected
Non21 10527-A-21 1 White paint dected Paint/binder 2 Cellulose
2
• •
SEATTLE ASBESTOS TEST ` /LAP Accreditation Lab codes: . 78,
Lynnwood Laboratory:19701 Sather Lake Road,Stile 103, Beleme Laboratory 12727 Nor8 Way.Suite 1.Bellevue, Searle Laboratory:4500 9er Ave.NE.Sage 3W.Seattle,WA 98105.
• Lynnwood,WA 98036.Tel 425.673.9850.Fax 425.6718010 WA 98005,Tel:425.861.1111.Fax 425 861.1118 Tet 208.633.1111.Fax 208.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA16001R-931116
+ = Mr.Herb Brod tier( ENS International,Inc. Adrift= 13228 NE 20th St#100,Bellevue,WA 98005
Jot: 10527-01r Balm({: 201310460 Date Received: 4/3/2013
samples Redd: 110 Date/wisheee 419/2013 Saevies• 110
Project Loc:
Federal Way High School-Block
Analyzed by. Liz GmcnlMary Eidmann Reviewed bF Save iFatyaoy Zhang,Presdent
Lab ID Client Sample ID Layer Description % Asbestos Fliers Non-fdxous
Components % Non-asbestos Fibers
None
2 Silver paint Paint/binder 2 Cellulose
3 Gray sandy/brittle None Sand, Filler, Binder 3 Cellulose
material detected
1 White paint Nd
one
Paint/binder 2 Cellulose
22 10527-A-22 2 Silver paint detected Paint/binder 4 Cellulose
3 Gray sandy/brittle None Sand, Filler, Binder 3 Cellulose
material detected
1 Beige paint Node PaintPaint 3 Cellulose
23 10527-A-23 2 White brittle None Filler, Binder 3 Cellulose
material detected
3 Gray sandy/brittle None Sand, Filler, Binder 5 Cellulose
material detected
1 White paint de Paint/binder 2 Cellulose
ted
Non
24 10527-A-24 2 Silver paint detected
4 Cellulose
Gray sandy/brittle None
3 material detected Sand, Filler, Binder 3 Cellulose
Non
1 Beige paint dtected Paint 3 Cellulose
25 10527-A-25 2 White brittle None Filler, Binder 2 Cellulose
material detected
3 Gray sandy/brittle None Sand, Filler, Binder 5 Cellulose
material detected
1 Beige paint deter Paint 2 Cellulose
26 10527-A-26 2 White brittle None Filler, Binder 2 Cellulose
material detected
3 Gray sandy/brittle None Sand, Filler, Binder 3 Cellulose
material detected
Black asphaltic
Filler,Asphalt,
1 material with 20 Chrysotile Binder 30 Cellulose
fibrous material
Multi-layered black Filler,Asphalt,
2 asphaltic fibrous 21 Chrysotile Binder 27 Cellulose
27 10527-A-27 material
3 Brown fibrous None Filler 90 Cellulose
material detected
Black asphaltic Filler,Asphalt,
4 material with 21 Chrysotile Binder 29 Cellulose
fibrous material
Black asphaltic Filler,Asphalt,
1 material with 20 Chrysotile Binder 30 Cellulose
28 10527-A-28 fibrous material
2 Black asphaltic None Asphalt/binder, 2 Cellulose
material detected Filler
3
• • o
SEATTLE ASBESTOS TEST NVLAP Accreditation Lab Co
Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory 12727 Narthup Way,Stale 1,Bellevue, Seattle Laboratory 4500 9th Ave NE.State 300.Seatte.WA 98105 •
Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tel 425.861.1111,Fax 425.861.1118 Tat:206.633.1111,Fax.205.633.474 7
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/R-93/116
Attn.: Mr.Herb Brod Gent EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005
Job#: 10527-01r Batde: 201310460 nate Received: 413/2013
Samples Redd: 110 Date Analyte 4/9/2013 samples Analyzed: 110
Loc.: Federal Way High School-Block
PrclectA
Analyzed by taz DunoNAtary Eidmarn Reviewed by: Steve(Fanyaol 2harg.President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
3 Black asphaltic 23 Chrysotile Filler,Asphalt, 30 Cellulose
fibrous material Binder
4 Black asphaltic 20 Chrysotile Filler,Asphalt, 28 Cellulose
fibrous material Binder
5 Black asphaltic 22 Chrysolite Filler,Asphalt, 31 Cellulose
fibrous material Binder
6 Black asphaltic 22 Chrysotile Filler,Asphalt, 29 Cellulose
fibrous material Binder
7 Black asphaltic 21 Chrysotile Filler,Asphalt, 23 Cellulose
fibrous material Binder
8 Brown fibrous None Filler 90 Cellulose
material detected
Black asphaltic Filler,Asphalt,
9 material with 20 Chrysotile Binder 29 Cellulose
fibrous material
29 10527-A 29 1 Gray cementitious None Cement/binder, 2 Cellulose
material detected Sands
1 White ceramic detested Ceramic/binder None detected
30 10527-A-30 2 White brittle None Binder 2 Cellulose
material detected
3 Tan mastic with None Mastic/binder, 4 Cellulose
paint detected Paint
Non
1 Gray ceramic dected Ceramic/binder None detected
Dark
2 gray brittle/sandy doetnected Binder, Sand 3 Cellulose
material
Dark
e
31 10527-A-31 3 gray sandy/brittle date a Binder, Sand 3 Cellulose
material
4 Yellow mastic None Masticlbinder, 4 Cellulose
detected Paint
Trace gray None
5 cementitious Cement/binder 2 Cellulose
detected
material
White brittle
No1 material with trace ste
eed Binder/filler, Paint 5 Cellulose
de32 10527-A-32 paint
2 White chalky None Binder/filler, 25 Cellulose,
material with paper detected Gypsum/binder Glass fibers
White brittle None
1 Binder/filler, Paint 4 Cellulose
33 10527-A-33 material with paint detected
2 White chalky None Binderlfiller, 26 Cellulose.
material with paper detected Gypsum/binder Glass fibers
1 White brittle None Binder/filler, Paint 5 Cellulose
34 10527-A-34 material with paint detected
2 White chalky None Binder/filler, 25 Cellulose.
material with paper detected Gypsum/binder Glass fibers
4
• s
SEATTLE ASBESTOS TEST
Lynnwood Laboratory:19701 Som Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way.Suite 1,Bellevue, Seattle Laboratory'4500 9th Ave.NE.Suite 300,Seattle,WA 98105.
Lynnwood,WA 98036,TeL 425.673.9850.Fax:425.673.9810 WA 98005,Tel:425.861.1111.Fax:425.861.1118 Tel.206.633.1111,Fax 206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/R-93/116
Amt.: Mr.Herb Brod Client EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005
Jowl: 10527-01r Batddt: 201310460 Date Received: 4/3/2013
Samples Recd 110 Date Aneyzed: 4/9/2013 Samples . 110
Federal Way High School-Block
Projed Loc.:
A
Analyzed by: Liz Dutton/Mary Eidmann Reviewed by: Steve(Fanyaol Zhang,President
Lab ID Chant Sample ID Layer Description % Asbestos Fibers Non-fibrous Components ',o Non-asbestos Fibers
White brittle None
1 Binder/filler, Paint 3 Cellulose
35 10527-A-35 material with paint detected
White chalky None Binder/filler, Cellulose,
2 material with paper detected Gypsum/binder 23 Glass fibers
White brittle None
1 Binder/filler, Paint 3 Cellulose
36 10527-A-36 material with paint detected
White chalky None Binder/filler, Cellulose,
2 material with paper detected Gypsum/binder 27 Glass fibers
Paint, Filler,
Gray fibrous None Cellulose,
37 10527-A-37 1 Pmaterial with paint detected erlite, Glass 66 Glass fibers
b
beads
38 10527-A-38 1 White soft/elastic None Binder, Filler None detected
material detected
1 Beige woven None Filler, Binder 85 Synthetic fibers
fibrous material detected
39 10527-A-39 2 Yellow mastic d tet�ed Masticbinder 3 Cellulose
3 Tan/gray mastic None Mastic/binder 4 Cellulose
detected
40 10527-A-40 1 White soft material None Binder, Filler, Paint 2 Cellulose
with paint detected
Gray/brown/yellow/ None Vinyl/binder,
1 white tile detected Mineral grains 2 Cellulose
41 10527-A-41 None
2 Black mastic detected Mastic/binder 6 Cellulose
1 Yellow mastic None Mastic/binder 2 Cellulose
detected
42 10527-A-42 2 Gray brittle None Filler, Binder 2 Cellulose
material detected
3 Black mastic None Mastic/binder 5 Cellulose
detected
1 Yellow mastic NonetMastic/binder 2 Cellulose
43 10527-A-43 2 White brittle None Filler, Binder 2 Cellulose
material detected
3 Black mastic None Mastic/binder 5 Cellulose
1 Red ceramic dcted
etee
cted Ceramic/binder None detected
44 10527-A-44 2 Gray brittle/sandy None Binder, Sand 2 Cellulose
material detected
3 Gray sandy/brittle None Binder, Sand 3 Cellulose
material detected
45 10527-A-45 1 Black asphaltic None Asphalt/binder 4 Cellulose
material detected
1 White paint None Paint/binder 2 Cellulose
46 10527-A-46 detected
2 Tan fibrous None Paint, Filler, Binder 65 Cellulose
material detected
5
• • .
SEATTLE ASBESTOS TES,..
Lynnwood Laboratory 19701 Scriber Lake Road,Suite 103 Bellevue Labordaey 12727 North*Way,Sure 1,Beiente, Seattle Laboratory 4500 Stir Ave.NE Siete 300 Searle,WA 98135
Lynnwood,WA 98036,Tel:425.673.9850.Fax:425 6730810 WA 98005,Tui:425.861.1 t 11,Far 425.861.1118 Tel 206.633.1111,Fax:206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/R 93/116
Mn.: Mr.Herb Brod orient ENS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005
Job* 10527-01r mishit 201310460 Dere Received: 4/3/2013
Samples Rodd: 110 Date Aridyzadd 4/9/2013 Samples Analyzed: 110
Project Loc.: Federal Way High School-Block 4--
A
Analyzed by (az Dolton/Mary Eidmann Reviewed by Steve(Fanyao)2bang..Presdent
Lab ID Client Sample ID Layer Description % Asbestos Filers Non-fibrous Components % Non-asbestos Fibers
3 White/brown None Filler, Binder 79 Cellulose
fibrous material detected
4 Brown mastic Nonel Mastic/binder 3 Cellulose,
1 cted
Brown rubbery 2 Chrysotile Rubber/binder 2 Cellulose
material
47 10527-A-47 one
2 Green mastic d Mastic/binder 5 Cellulose
etected
Brown/yellow
on3 mastic with deteected Mastic/binder 7 Cellulose
powdery material
1 Brown vinyl 2 Chrysotile Vinyl/binder 3 Cellulose
48 10527-A-48 2 Yellow mastic None Mastic/binder 6 Cellulose
detected
1 Brown vinyl 2 Chrysotile Vinyl/binder 2 Cellulose
49 10527-A-492 Brown mastic None
detected Mastic/binder 5 Cellulose
1 Brown rubbery None Rubber/binder 3 Cellulose
material detected
50 10527-A-50 2 Cream mastic Ndete ed Mastic/binder 5 Cellulose
3 Tan/brown mastic deed Mastic/binder 6 Cellulose
1 Beige rubbery None Rubber/binder 3 Cellulose
51 10527-A-51 material detected
2 Cream mastic detected Mastic/binder 4 Cellulose
1
Dark None Mastic/binder 4 Cellulose
52 10527-A-52 brown/gray mastic detected
2 Tan wood debris detected Wood debris 7 Cellulose
1 White brittle None Binder/filler, Paint, 5 Cellulose
53 10527-A-53 material with paint detected Sands
2 White chalky None Binder/filler, Cellulose,
material with paper detected Gypsum/binder 29 Glass Fibers
1 White brittle None Binder/filler, Paint, 3 Cellulose
54 10527-A-54 material with paint detected Sands
2 White chalky None Binder/filler, 31 Cellulose,
material with paper detected Gypsum/binder Glass Fibers
1 White brittle None Binder/filler, Paint, 4 Cellulose
55 10527-A-55 material with paint detected Sands
2 White chalky None Binder/filler, 25 Cellulose,
material with paper detected Gypsum/binder Glass Fibers
1 White brittle None Binder/filler. Paint, 3 Cellulose
56 10527-A-56 material with paint detected Sands
2 White chalky None Binder/filler, 23 Cellulose.
material with paper detected Gypsum/binder Glass Fibers
57 10527-A-57 1 White brittle None Binder/filler, Paint, 2 Cellulose
material with paint detected Sands
6
•
SEATTLE ASBESTOS TEST
Lyrviwood Laboratory.19701 Saber take Road,Site 103, Bellevue Laboratory:12727 trodbup Way.Sate 1,revue. Seattle Laboratory 4520 9a1 Ave.NE,Stile 300,Seat le,WA 98105,
• Lynnwood,WA 98036,Tel:425.673.9850.Far 425.673.9810 WA 98005,Tet 425.861.1111,Fax 425.861 1118 -el:205.633.1111,Far 206.933.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPAf600/R-93/116
Attn.: Mr.Herb Brod (=tent EHS International,Inc. Addresr 13228 NE 20th St#100,Bellevue.WA 98005
Jobe 10527-01r Biu: 201310460 Date Received: 4/3/2013
samples Read: 110 Dees Me.Yyzad: 4/9/2013 samples Analyzed: 110
Loc-:. Federal Way High School-BlockProject —
A -0121110
Analyzed by: Liz Otrec tklary Eidrnarn Reviewed by: Steve{Fa:yaoi Znany,.Presnent
Lab ID Client Sample ID Layer Description % Asbestus Fibers Non-fibrous Components % Non-asbestos Fibers
White chalky None Binder/filler, Cellulose,
2 material with paper detected Gypsum/binder 29 Glass Fibers
Black soft/elastic
58 10527-A-58 1
material with None Filler, Binder, Paint 30 Glass fibers
woven fibrous detected
material and paint
59 10527-A-59 1 Tan soft material None Filler, Binder 6 Cellulose,
detected Wollastonite
Tan fibrous None
1 material with white detected Filler, Paint 90 Cellulose
60 10527-A-60 paint
No2 Brown mastic ntected Mastic/binder 3 Cellulose,
deYellow mastic with
61 10527-A-61 1 white brittle None Mastic/binder 2 Cellulose
material and wood detected
debris
White brittle
1 material with paint None Binder/filler, Paint, 13 Cellulose,
62 10527-A-62 and woven fibrous detected Sands Glass Fibers
material
White chalky None Binder/filler, Cellulose,
2 material with paper detected Gypsum/binder 23 Glass Fibers
1 White brittle None Binder/filler, Paint, 4 Cellulose
63 10527-A-63 material with paint detected Sands
White chalky None Binder/filler, Cellulose,
2 material with paper detected Gypsum/binder 25 Glass Fibers
1 White powdery 2 Chrysotile Binder/filler 2 Cellulose
64 10527-A-64 material
2 Pink chalky None Binder/filler, 25 Cellulose
material with paper detected Gypsum/binder
1 White powdery 2 Chrysotile Binder/filler, Paint 4 Cellulose
65 10527-A-65material with paint
2 Pink chalky None Binder/filler, 26 Cellulose
material with paper detected Gypsum/binder
White brittle
1 material with paint None Binder/filler; Paint, 3 Cellulose
66 10527-A-66 and powdery detected Sands
material
White chalky None Binder/filler, Cellulose,
2 material with paper detected Gypsum/binder 25 Glass Fibers
White brittle None Binder/filler, Paint,
1 5 Cellulose
67 10527A-67 material with paint detected Sands
White chalky None Binder/filler, Cellulose.
2 material with paper detected Gypsum/binder 23 Glass Fibers
1 White brittle None Binder/filler, Sands 5 Cellulose
68 10527-A-68material detected
2 White chalky None Binder/filler, 24 Cellulose,
material with paper detected Gypsum/binder Glass Fibers
7
• .
NVLAP&meditation Lab Codes: 200878,L 20t
Lynnwood Laboratory-19701 Saioer Lake Road,Suite 103, Bellevue Laboratory:11x1!Ncethp Way,Sine 1.Bim, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105,
Lynnwood,WA 98036,Tel.425.673.9850,Far:425.673,9810 WA 98005,Te!'425.881.1111,Faxc 425.861.1118 Tel-208.633.1111,Fax:206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/I300/R-93/116
AIM.: Mr.Herb Brod Client EHS International,Inc. Address 13228 NE 20th St#100.Bellevue,WA 98005
Job#: 10527-01r Bal: 201310460 Data Received: 4/3/2013
samples Reed: 110 Date Analyzed: 4/9/2013
samples Arrehrmd: 110
Project Loc.: Federal Way High School-Block `
A t
Analyzed by Liz Duttor:A4ary Eidman Reviewed by Steve(Fanyao)Zhang,President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
None
1 White paint Paint/binder 2 Cellulose
detected
69 10527-A-69 Gray sandy/brittle None
2 material detected Sand, Filler, Binder 3 Cellulose
None
1 White paint Paint/binder 2 Cellulose
detected
70 10527-A-70 Gray sandy/brittle None
2 material detected Sand, Filler, Binder 4 Cellulose
None
1 Gray paint Paint/binder 2 Cellulose
detected
71 10527-A-71
2 Gray sandy/brittle None Sand, Filler, Binder 2 Cellulose
material detected
1 Brown ceramic None Ceramic/binder None detected
detected
2 Gray brittle/sandy None Binder, Sand 2 Cellulose
72 10527-A-72 material detected
3 Beige mastic d°neteected Mastic/binder 2 Cellulose
4 Gray brittle/sandy None Binder, Sand 2 Cellulose
material detected
73 10527-A-73 1 Gray soft/elastic Norte Binder, Filler 4 Cellulose
material detected
Black foamy None Synthetic foam,
74 10527-A-74 1 material with paint detected Paint, 2 Cellulose
and mastic Mastic/binder
1 White soft/elastic None Binder, Filler, Paint 4 Cellulose
material with paint detected
75 10527-A-75 Trace gray
2 sandy/brittle detected Sand, Filler, Binder 3 Cellulose
material
Black mastic with None Mastic/binder,
76 10527-A-76 1 debris detected Debris, Fine 5 Cellulose
particles
1 White ceramic None Ceramic/binder None detected
detected
77 10527-A-77 2 White None Binder 2 Cellulose
brittle material detected
3 Tan mastic None Mastic/binder 3 Cellulose
detected
one
1 Gray ceramic d Ceramic/binder None detected
2 etected
Gray brittle/sandy None Binder, Sands 4 Cellulose
material detected
3 Yellow mastic None Mastic/binder 3 Cellulose
78 10527-A-78 detected
Dark gray
4 brittle/sandy de�teeted Binder, Sands 4 Cellulose
material
5 Gray cementitious None Cement/binder,
material detected Sands 2 Cellulose
8
411 1111
,
SEATTLE ASBESTOS TEST
Lynnwood Laboratory:19701 Scriber lake Road,Sale 103, Belem,Laboratory 12727 Narep Way.Sine 1,8eleave, Seattle Laboratory.4500 341 Ave.NE Bute 2,93 Seattle,.1'4 931;5..
Lynnwood.WA 98336,Tel:425.6739450,Fax:425.573.9610 WA 961106,Tet:425.361 1111,Fax 425.861.1118 Tel 266.633.1111.Far 236.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/R-931116
Atm.: Mr.Herb Brod am* EHS International,Inc_ Address: 13228 NE 20th St#100,Bellevue,WA 98005
.low: 10527-01r Bad: 201310460 Date Received: 4132013
Samples Reed: 110 oats Analyzed: 4192013 Samples Analyzed: 110
Federal Way High School-Block
Protect LOG: A
Analyzed by: Liz Duttonlaary ESS ane Reviewed by: Steve IFanyaoi 2tag.Preslden•.
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
79 10527-A-79 1 Beige soft/elastic None Binder, Filler 2 Cellulose
material detected
80 10527-A-80 1 Beige soft/elastic None Binder, Filler 3 Cellulose
material detected
None
81 10527-A-81 1 Gray soft material Filler, Binder 5 Cellulose
detected
Yellow/tan soft 'None Cellulose,
82 10527-A-82 1 material detected Filler, Binder 3 Wollastonite
1 Black sandy/brittle None Sand. Filler, Binder 3 Cellulose
material detected
Trace
83 10527-A-83 2 gray sandy/brittle None Sand, Filler; Binder 3 Cellulose
etected
material
None
3 Brown wood debris de ed Wood debris 7 Cellulose
Off None Filler, Fine
84 10527-A-84 1 white soft/loose detected particles 5 Cellulose
material
White brittle None
1 Filler, Binder, Paint 2 Cellulose
85 10527-A-85 material with paint detected
2 Gray sandy/brittle None Sand, Filler, Binder 4 Cellulose
material detected
White brittle None
1 Filler, Binder; Paint 2 Cellulose
86 10527-A-86 material with paint detected
Gray sandy/brittle None
2 material detected Sand,Filler, Binder 3 Cellulose
White brittle None
1 material with paint detected Filler, Binder, Paint 3 Cellulose
87 10527-A-87 Gray sandy/brittle None
2 material detectedSand, Filler. Binder 3 Cellulose
None Cellulose,
1 Yellow masticdetectedMastic/binder 5 Synthetic fibers
88 10527-A-88 2 Brown tile 3 Chrysotile Vinyl/binder, 2 Cellulose
Mineral grains
3 Black mastic detected Mastic/binder 4 Cellulose
1 Yellow mastic None Mastic/binder 6 Cellulose,
detected Synthetic fibers
Gray
e
89 10527-A-89
2
material detected Filler, Binder 3 Cellulose
3 Brown tile 3 Chrysotile Vinyl/binder, 3 Cellulose
Mineral grains
4 Black mastic detected Mastic/binder 4 Cellulose
90 10527 A-90 1
Green/dark gray None Filler, Binder 4 Cellulose
soft material detected
None
91 10527-A-91 1 Gray soft material Filler, Binder 2 Cellulose
detected
92 10527-A-92 1 White brittle None Filler, Binder, 3 Cellulose
material detected Perlite
9
• •
NVLAP Accreditation Lab Codes: 76,Lyr nwwcod-200768
Lynnwood Labo'aiory-19701 So-bar Lake Road.State 103, Bellevue Laboratory:12727 Narthup Wey,Stine 1,eeievae, Seatle Laboratory:45009th Ave.I'E.Suite 300,Seattle,WA 98105,
Lynnwood WA 980336.T 425.673.9850,Fax 425.673.9810 WA 9e8005,Tel:425.861.1111,Fax 425.861.1118 Tel 206833,1111,Fax 208.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA1600/R-93/116
Atm.: Mr.Herb Brod (Sent EHS International,Inc. Aeaesc 13228 NE 20th St#100,Bellevue,WA 98005
Jaw 10527-01r Sat 201310460 Date Receive& 4/3/2013
semdes Redd: 110 Date Analyzed: 4/9/2013 samples Maiyzed: 110
Project # i
Loc. Federal Way High School-Block
A
Analyzed by Liz DeffionAtary Eidmam Reviewed by. Steve tFanyaol Zttan9.€rescent
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
White/gray fibrous None Paint, Filler,
1 Perlite, Glass 68 Cellulose.
93 10527-A-93 material detected Glass fibers
fibers
2 Brown mastic None Mastic/binder 3 Cellulose
detected
1 Light None Vinyl/binder,
gray/white/gray tile detected Mineral grains 2 Cellulose
94 10527-A-94 2 Yellow mastic None Mastic/binder 4 Cellulose
detected
3 Black mastic None Mastic/binder 5 Cellulose
detected
1 Blue tile None Vinyl/binder,
detected Mineral grains 2 Cellulose
95 10527-A-95 2 Yellow mastic None Mastic/binder 4 Cellulose
detected
3 Black mastic None Mastic/binder 5 Cellulose
detected
1 Blue woven fibrous None Filler, Binder 85 Synthetic fibers
material detected
2 Yellow mastic None Mastic/binder 3 Cellulose
96 10527-A-96 detected
3 Gray brittle None
material detected Filler, Binder 2 Cellulose
4 Black mastic 3 Chrysotile Mastic/binder 3 Cellulose
97 10527-A-97 1 Tan soft material None Filler, Binder 3 Cellulose
detected
Red rubbery None Rubber/binder,
98 10527-A-98 1 material with soft 4 Cellulose
material detected Filler
99 10527-A-99 1 Black soft/elastic None
material detected Binder, Filler 2 Cellulose
100 10527-A-100 1 White soft/elastic None
material detected Binder, Filler 2 Cellulose
Black asphaltic
101 10527-A-101 1 material with None Asphalt/binder,
brown woven detected Filler 63 Cellulose
fibrous material
Black asphaltic
102 10527-A-102 1 material with Nate Asphalt/binder,
brown woven detected Filler 26 Cellulose
fibrous material
103 10527-A-103 1 White brittle None
material detected Filler, Binder 2 Cellulose
1 Brown cork None Cork
detected None detected
104 10527-A 104 2 White powdery None
material detected Filler, Binder 2 Cellulose
3 Gray cementitious None Cement/binder,
material detected Sands None detected
10
•
SEATTLE ASBESTOS TEST•
Lynnwood laboratory:19701 Scriber Lake Road.Sode 103. aeaewe Laboratory:12727 Nordsp W`ay,Sure 1.Bellevue, Seale Laboratory:4500 981 Ave NE,Suite 300.Seattle.WA 98105.
Lymwood,WA 98036,Tel:425.673.9850,Fax 425.673.9810 WA NOM.Tel:425.861_1111.Fax 425.861.1118 T .206.633.1111,Fax 206.633.4747
ANALYTICAL LABORATORY REPORT
PCM by Method EPA/60OlR-93/116
Ann: Mr.Herb Brod meet EHS International,Inc. Mike= 13228 NE 20th St#100,Bellevue,WA 98005
.tart 10527-01r Bay 201310460 Dete Realest 4/3/2013
sanplea Redd: 110 Dam Mehr 4/9(2013 srmpies MalYaart 110
Project t . Federal Way High School-Block
A
Analyzed by L¢Dutton9ary Eidnran Reviewed try Steve(Fanyao)Zhang.Prescient
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
White brittle None Binder/filler, Paint,
1 5 Cellulose
105 10527-A-105 material with paint detected Sands
2 White chalky None Binder/filler, 23 Cellulose,
material with paper detected Gypsum/binder Glass Fibers
White brittle None Binder/filler, Paint,
1 3 Cellulose
106 10527-A-106 material with paint detected Sands
2 White chalky None Binder/filler, 26 Cellulose,
material with paper detected Gypsum/binder Glass Fibers
1 White brittle None Binder/filler, Paint, Cellulose
4
107 10527-A--107 material with paint detected Sands
2 White chalky Norte Binder/filler, 24 Cellulose,
material with paper detected Gypsum/binder Glass Fibers
1 Black loose brittle None Filler, Binder 2 Cellulose
108 10527-A-108 material detected
Gray sandy/brittle None
2 material detected Sand, Filler, Binder 3 Cellulose
109 10527-A-109 1 Gray soft/elastic None Binder, Filler, Paint 4 Cellulose
material with paint detected
110 10527 A-110 1
White soft/elastic None Binder, Filler 2 Cellulose
material detected
•
11
• S
SEA$ ASBESTOS TEST Accri,irlitatIonLab C t s.,?:ell.,v e-2005 Lynnwood-250753
Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory-4500 9th Ave.NE,Suite 300,Seattle,WA 98105,
Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tel.425.861.1111,Fax:425.861.1118 Tel:206633-1111.Fax:206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/R-93/116
Attn.: Mr.Herb Brod client EHS International,Inc. Adm: 13228 NE 20th St#100,Bellevue,WA 98005
Job#: 10527-01R Batct 201310610 Date Received: 4/10/2013
Samples Redd: 11 Pate Analyzed: 4/17/2013 Samples Analyzed: 11
Federal Way High School,Block ' /j
Project Loc.: A i
Analyzed by: Ryan Antolock Reviewed by: Steve(Fanyao)Zhang,President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
Pink/white fibrous None Filler, Fine
1 material with trace detected particles, 87 Cellulose
1 10527-A-111 mastic Mastic/binder
None
2 Brown wood debris detected Wood debris 6 Cellulose
Pink/yellow fibrous None Filler, Fine
2 10527-A-112 1 material with detected particles, 89 Cellulose
mastic Mastic/binder
Pink/yellow fibrous None Filler, Fine
1 material with particles, 90 Cellulose
3 10527-A-113 mastic
detected Mastic/binder
None
2 Brown wood debris detected Wood debris 7 Cellulose
Pink/yellow fibrous None Filler, Fine
1 material with detected particles, 88 Cellulose
4 10527-A-114 mastic Mastic/binder
2 Brown wood debris None Wood debris 6 Cellulose
detected
Pink/white fibrous None Filler, Fine
1 material with trace particles, 86 Cellulose
mastic detected Mastic/binder
5 10527-A-1152 White powdery None Binder/filler 32 Cellulose
material with paper detected
3 White chalky None Binder/filler, Cellulose,
material with paper detected Gypsum/binder 37 Glass fibers
Pink/white fibrous Filler, Fine
1 material with None particles, 85 Cellulose
detected Mastic/binder
6 10527-A-116 mastic
2 White chalky None Binder/filler, Cellulose,
material with paper detected Gypsum/binder 38 Glass fibers
Pink/white fibrous None Filler, Fine
1 material with particles, 91 Cellulose
7 10527-A-117 mastic
detected Mastic/binder
2 White chalky None Binder/filler, 40 Cellulose,
material with paper detected Gypsum/binder Glass fibers
1 Brown paper with None Filler, 77 Cellulose
asphaltic material detected Asphalt/binder
None
2 Brown wood block detected Wood aggregates 5 Cellulose
8 10527-A-118 Black asphaltic
fibrous material Filler,Asphalt, 33 Cellulose
3 with asphaltic 21 Chrysotile Binder
material
None
1 Brown wood block detected Wood aggregates 6 Cellulose
9 10527-A-119 2 Brown paper with None Filler, 79 Cellulose
asphaltic material detected Asphalt/binder
3 Brown wood block None Wood aggregates 7 Cellulose
detected
1
• •
SEATTLE
EATE ASBESTOS TEST ?..i.itliP Accreditation Lab�e�ss_Etei ietue-2;£8f3,Ly ri oadh
OOr6$
Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory 12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105,
Lynnwood,WA 98036,Tel:425673.9850,Fax:425.673.9810 WA 98005,Tel:425.861.1111,Fax 425.861.1118 Tel:206.633.1111,Fax 206.533.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPN600/R-93/116
Attn.: Mr.Herb Brod client EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005
,lob#: 10527-01R Batch# 201310610 Date Received: 4/10/2013
Samples Redd: 1 1 Date Analyzed: 4(17/2013 Samples Analyzed: 11
ectLoa: Federal Way High School,Block r7 (,;;Z.,'
ProjAnalyzed by: Ryan Antolock Reviewed by: Steve(Fanyao)Zhang,President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
Multi-layered black Filler,Asphalt,
4 asphaltic fibrous 19 Chrysotile Binder, Fine 37 Cellulose
material with particles, Debris
debris
5 Black asphaltic None Asphalt/binder 3 Cellulose
material detected
1 Brown wood block Nonet ed Wood aggregates 7 Cellulose
2 Brown paper with None Filler, 78 Cellulose
asphaltic material detected Asphalt/binder
10 10527-A-120 3 Brown wood block ducted Wood aggregates 5 Cellulose
Black asphaltic
4 fibrous material 20 Chrysotile Filler,Asphalt, 36 Cellulose
with asphaltic Binder
material
Brown wood None
11 10527-A-121 1 debris with fibrous detected Wood debris, Filler 27 Cellulose
material
2
• •
SEATTLE ASBESTOS TEST NVLAP Accreditation Lan Codes.200768 and 200876
19711 Scriber Lake Road,Suite 0,Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810
12727 Northup Way.Suite 1,Bellevue,WA 98005,Tel:425.861.1111,Fax:425.861.1118
Website:vnvw.seatlieasbestostesLcom,Email:admin(r seatfeasbestostestcom
PLM by Point Count(400 Points)
Client Job#: 10527-01r
Attention: Mr.Herb Brod Laboratory Batch#: 201310867
Client: EHS international,Inc_ Date Received: 4/22/2013
Address: 13228 NE 20th St#100,Bellevue,WA 98005 Samples Received: 2
Date Analyzed: 4/25/2013
Project: Federal Way High School-Block A
Sample Requested for Point Count 10527-A-64
Previous Analytical Information
Previously Analyzed by: Liz Dutton
Previous Batch#: 201310460
Previous Lab ID: 64
Previous Description: White powdery material
Layer to be Point Counted: 1
Asbestos Type Found: Chrysotile
Asbestos Percentage Found: 2
Point Count Analytical Procedures New Lab ID: 1
Asbestos Points Non-Asbestos Points Total Points Counted
Slide 1 0 50 50
Slide 2 0 50 50
Slide 3 0 50 50
Slide 4 1 49 50
Slide 5 1 49 50
Slide 6 0 50 50
Slide 7 0 50 50
Slide 8 0 50 50
Total 2 398 400
Point Count Summary Results
Type of Asbestos: Chrysotile
Percentage of Asbestos: 0.5%
Analyzed By: Liz Dutton Reviewed by: Steve(Fanyao)Zhang, President
1
• •
SEATTLE ASBESTOS TEST NVLAP Accreditation Lab Codes:200768 and 200876
19711 Scriber Lake Road,Suite D,Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810
12727 Northup Way,Suite 1,Bellevue,WA 98005,Te1:425.861.1111,Fax:425.861.1118
Website:www.seattleasbestostest.com,Email:admin@seattleasbestostest.com
PLM by Point Count(400 Points)
Client Job#: 10527-01r
Attention: Mr.Herb Brod Laboratory Batch#: 201310867
Client: EHS International,Inc. Date Received: 4/22/2013
Address: 13228 NE 20th St#100,Bellevue,WA 98005 Samples Received: 2
Date Analyzed: 4/25/2013
Project: Federal Way High School-Block A
Sample Requested for Point Count 10527-A-65
Previous Analytical Information
Previously Analyzed by: Liz Dutton
Previous Batch#: 201310460
Previous Lab ID: 65
Previous Description: White powdery material with paint
Layer to be Point Counted: 1
Asbestos Type Found: Chrysotile
Asbestos Percentage Found: 2
Point Count Analytical Procedures New Lab ID: 2
Asbestos Points Non-Asbestos Points Total Points Counted
Slide 1 1 49 50
Slide 2 0 50 50
Slide 3 0 50 50
Slide 4 0 50 50
Slide 5 0 50 50
Slide 6 2 48 50
Slide 7 0 50 50
Slide 8 0 50 50
Total 3 397 400
Point Count Summary Results
Type of Asbestos: Chrysotile
Percentage of Asbestos: 0.75%
Analyzed By: Liz Dutton Reviewed by: Steve(Fanyao)Zhang,President
2
• •
SEATTLE ASBESTOS TEST NVLAP Ambditabort Lab Codes
Lynnwood Laboratory 19701 Scriber Latta Road.Sade 103, Bellevue Laboratory 12727 Narltlup Way,Site 1,Bellevue, Seattle Laboratory.4500 9th Ave.NE,Seale 300.Seale,WA 98105.
Lynnwood,WA 98036,Tet:425.673.9850.Fax:425.673.9610 YIrr190005,Tet:425.861.1111,Fax:425.861.1118 TeL 206.633.1111,FaX 206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA1600/R-93/116
Attr1.: Mr.Herb Brod Client EHS International.Inc. : 13228 NE 20th St#100,Bellevue,WA 98005
.Jobe. 10527-01r setdet: 201310461 Date Received: 413/2013
Se pies Recd 20 Oate Analyzed: 4/10/2013 es
FederalFWay High School-BlockProject Loc.: �—
Analyzed by Sarah Huang/Liz VT,on Reviewed by. Steve jFanyaol ZFarng.Freadent
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fbrous Components % Non-asbestos Fibers
1 10527-B-01 1 Light gray soft None Filler, Binder 3 Cellulose
material detected
1 Tan rubbery None Rubber/binder, 2 Cellulose
2 10527-B-02 material with paint detected Paint
Creme None
2 Mastic/binder 2 Cellulose
golored mastic detected
3 10527 B-03 1 White sandy/brittle None Sand, Filler, 3 Cellulose
material with paint detected Binder, Paint
4 10527-6-04 1 White sandy/brittle None Sand, Filler, 2 Cellulose
material with paint detected Binder, Paint
5 10527-B-05 1 White sandy/brittle None Sand, Filler, 3 Cellulose
with paint detected Binder, Paint
1 Light gray tile None Vinyl/binder, 2 Cellulose
detected Mineral grains
6 10527-B-06 2 Yellow mastic de�teected Mastic/binder 3 Cellulose
3 Gray brittle None Binder 4 Cellulose
material detected
TanMlhite fibrous None
1 Binder, Paint 67 Cellulose
7 10527-6-07 with paint detected
one
2 Black soft material deteed Binder 3 Glass fibers
1 Blue Tile None Vnyl/binder, 2 Cellulose
detected Mineral grains
8 10527-6-08 2 Yellow mastic No
entected Mastic/binder 3 Cellulose
3 Black mastic None Mastic/binder 3 Cellulose
detected
9 10527-B-09 1 Gray brittle None Filler, Binder, Paint 2 Cellulose
material with paint detected
White brittle None
1 Filler, Binder, Paint 3 Cellulose
10 10527-B-10 material with paint detected
2 White chalky None Binder/filler, 25 Cellulose
material with paper detected Gypsum/binder
White brittle None
1 Filler, Binder, Paint 5 Cellulose
11 10527-B-11 material with paint detected
2 White chalky None Binder/filler, 36 Cellulose
material with paper detected Gypsum/binder
White brittle None
1 Filler, Binder, Paint 4 Cellulose
12 10527-B-12 material with paint detected
2 White chalky None Binder/filler, 35 Cellulose
material with paper detected Gypsum/binder
White brittle None
1 Filler, Binder, Paint 7 Cellulose
13 10527-B-13 material with paint detected
2 White chalky None Binder/filler, 23 Cellulose
material with paper detected Gypsum/binder
White brittle None
14 10527-B-14 1 Filler, Binder, Paint 2 Cellulose
material with paint detected
1
II •
SEATTLE ASBESTt -EST
Lynnwood Laboratory'19791 Scriber Lake Road.Suite 103. Bellevue Laboratory:12727 Norttup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE.Suite 300.Seattle,WA 98105,
Ly!nwwd,WA 98036,Td:425.673.9850.Fax:425.673.9810 WA 98005,Tel:425.861.1111,Fax:425.861.1118 Tel'206.633.1111,Fax:206.633.4747
ANALYTICAL LABORATORY REPORT
PIM by Method EPA/600/R-93/116
Aekc Mr.Herb Brad client EHS International,Inc Address: 13228 NE 20th St#100,Bellevue,WA 98005
Joblk 10527-01r Batt* 201310461 Date Received: 4/3/2013
Samples Recd: 20 Date Analyze& 4/10/2013 Samples Analyzed: 20
Protect Loc. Federal Way High School-Block .„.„---.=: ...'
B
Analyzed by: Sarah Huang/Liz Dub. Reviewed by. Steve(Fanyao)Zhang,President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
2 White chalky None Binder/filler, 32 Cellulose
material with paper detected Gypsum/binder
15 10527-B-15 1 Gray fibrous None Paint, Filler, Perlite 65 Cellulose
material with paint detected
1 Gray fibrous None Paint, Filler, Perlite 65 Cellulose
16 10527-B-16 material with paint detected
None
2 Brown masticected Mastic/binder 2 Cellulose,
1 Red ceramic None Ceramic/Binder None detected
17 10527-8-17 quarry Tile detected
2 Gray brittle/sandy None Binder, Sand 2 Cellulose
material detected
18 10527-B-18 1 Black soft material None Binder, Paint 2 Cellulose
with paint detected
1 Brown fibrous None Filler, Paint 90 Cellulose
material with paint detected
19 10527-8-19 2 Brown mastic d e�ted Mastic/binder 3 Cellulose
3 Tan fibrous None Filler, Binder 65 Cellulose
material detected
Gray fibrous None
1 material with paint detected Paint, Filler, Perlite 65 Cellulose
20 10527-B-20 White Plastic None
2 material detected Plastic None detected
2
• • . •
Iv-
SEATTLE
SEATTLE ASBESTOS TEST NVLAP Accradttation Lab Codes: 200876,Lynnwood-200768
Lynnwood Laboratory:19701 Satter Lake Road,Suite 103, 6e8evue Laboratory:12727 Nordntp hey,Stite 1.Bellevue, Seattle Laboratory:4500 91h Ave.NE,Suite 300,Seattle,WA 9810.5.
Lynnwood,WA 98036.Tel:425.673.9850,Fax 425.673.9810 WA 96005.TeL 425.861.1111.Fax 425.861.1118 Tel:206.633.1111,Far 206.633.4747
ANALYTICAL LABORATORY REPORT
PIM by Method EPA/600IR-931116
Am>.: Mr.Herb Brod dent: EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005
Job#: 1 0527-01 r Barth. 201310529 Data Receive& 4/5/2013
Samples Redd: 13 Date Anayaed: 4/12/2013 �- —es - 13
Federal Way High School-BlockProiect Loc.: `
B
Araiyzed by: di.mithh Reviewed by: Steve(Fanyao)7hang,Pres4wt
Lab ID Client Sample ID Layer Description •• ,•:Fibers Non-fibrous Components % Non-asbestos Fibers
Black soft/elastic None
1 Binder, Filler 2 Cellulose
1 10527-B-21 material detected
1 White soft/elastic None Binder, Filler, Paint 4 Cellulose
material with paint detected
1 Gray soft/elastic None Binder, Filler 2 Cellulose
2 10527-B-22 material with paint detected _
1 Silver soft/elastic None Binder, Filler 4 Cellulose
material detected
1 Cream rubbery None Rubber/binder 2 Cellulose
material detected _
2 Cream mastic de
emoted Mastic/binder 3 Cellulose
3 10527-B-23 White powdery None
3 material with paint detected Binder/filler, Paint 4 Cellulose
4 White chalky None Binder/filler, 21 Cellulose
material with paper detected Gypsum/binder
4 10527-B-24 1 Gray brittle 3 Chrysotile Filler, Binder, Paint 2 Cellulose
material with paint
1 Tan rubbery None Rubber/binder 2 Cellulose
material detected
5 10527-B-25 2 Cream mastic None Mastic/binder 3 Cellulose
detected
3 Brown mastic 3 Chrysotile Mastic/binder 5 Cellulose
White brittle None
1 Filler, Binder, Paint 3 Cellulose
6 10527-B-26 material with paint detected
2 White chalky None Binder/filler, 21 Cellulose,
material with paper detected Gypsum/binder Glass fibers
White brittle None
1 Filler, Binder, Paint 4 Cellulose
7 10527-8-27 material with paint detected
2 White chalky None Binder/filler, 25 Cellulose,
material with paper detected Gypsum/binder Glass fibers_
White brittle None
1 Filler, Binder, Paint 3 Cellulose
8 10527-B-28 material with paint detected
White chalky None Binder/filler, Cellulose,
2 material with paper detected Gypsum/binder 26 Glass fibers_
Yellow/tan soft None
9 10527-B-29 1 material with detected Filler, Binder 7 Cellulose,Talc
fibrous material
White chalky Binder/filler,
10 10527-B-30 1 material with paint None Gypsum/binder, 32 Cellulose,
and paper detected Paint Glass fibers
11 10527 B-31 1 Brown mastic with None Mastic/binder, 24 Cellulose
fibrous material detected Filler
12 10527-B-32 1 Gray brittle 3 Chrysotile Filler, Binder, Paint 3 Cellulose
material with paint
13 10527-B-33 1 Black soft rubbery None Rubber/binder 2 Cellulose
material detected
1
. • •
ASBESTOS TEST N'/LAP A^w^"edit 7th tt Lab'odes:Bellevue-200876,Lynnwood-200765
Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103. Bellevue Laboratory:12727 Northup Way,Suite 1,Bellows, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105,
Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tel:425.861.1111,Fax:425.861.1118 Tel:206.833.1111,Fax:206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/R-93/116
Mn.: Mr.Herb Brod cllent EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005
.lab#: 10527-01r Batch# 201310528 Date Received: 4/5/2013
Samples Recd: 127 Date Analyzed: 4/11/2013 Samples Analyzed: 127
Federal Way High School-Block yrs w!
Project Loc.: C j
Analyzed by. RyaC Antolodc Reviewed by: Steve(Fanyao)Zhang.President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
1 Gray soft/elastic None Binder, Filler 4 Cellulose
material detected
1 10527-C-01 Black foamy None Synthetic foam,
2 material with paint detected Paint, 3 Cellulose
and mastic Mastic/binder
1 Black soft/elastic None Binder, Filler, Paint 4 Cellulose
2 10527-C-02 material with paint detected
2 Brown wood debris None Wood debris 6 Cellulose
detected
Black rubbery None Rubber/binder 2 Cellulose
1 material detected
3 10527-C-03 Cream mastic with None Mastic/binder,
2 4 Cellulose
trace wood debris detected Wood debris
Black soft/loose Filler, Fine
4 10527-C-04 1 material 3 Chrysotile particles 5 Cellulose
None Vinyl/binder, 2 Cellulose
1 Off-white tile detected Mineral grains
5 10527-C-05 2 Yellow mastic de®t ectad Mastic/binder 4 Cellulose
3 Gray brittle None Filler, Binder, Sand 3 Cellulose
material detected
Gray foamy None Synthetic foam,
1 material with2 Cellulose
detected Mastic/binder
6 10527-C-06 mastic
2 Gray brittle None Filler, Binder, Sand 3 Cellulose
material detected
7 10527-C-07 1 Gray fibrous None Paint, Filler, Perlite 67 Cellulose
material with paint detected
Brown fibrous None
1 material with trace detected Filler, Paint 88 CellUlose
8 10527-C-08 paint
Brown mastic with None Mastic/binder,
2 23 Cellulose, Talc
Filler
paper detected
1 White powdery None Binder/filler, Paint 4 Cellulose
9 10527-C 09 material with paint detected
2 White chalky None Binder/filler, Cellulose,
material with paper detectedypsu34
Gypsum/binder Glass fibers
1 White powdery None Binder/filler, Paint 5 Cellulose
10 10527 C-10 material with paint detected
2 White chalky None Binder/filler, 37
d Gsum/binder Cellulose,
material with paper detecteypGlass fibers
White powdery None
1 material with paint detected Binder/filler, Paint 36 Cellulose
11 10527-C-11 and paper
2 White chalky None Binder/filler, Cellulose,
material with paper detectedypsum31
Gypsum/binder Glass fibers
Brown fibrous None
1 Filler, Paint 89 Cellulose
12 10527-C-12 material with paint detected
2 Brown mastic None Mastic/binder 5 Cellulose, Talc
detected
1
. . •
r
S Ark L<" ASEFSTOS t FST i i...: p,.«<iez tu:.<c:.l�-;J Ocijaz:BT?it^.°,fes..,-20075 L,;>.r1wt3 ,x.200`$0
Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105, _
Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tel:425.861.1111,Fax:425.861.1118 Tel 206.633.1111,Fax:206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/R-931116
Mn.: Mr.Herb Brod Kent EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005
Job#: 10527-01r Batddk. 201310528 Date Received: 415/2013
Samples Redd: 127 Date Anatyzed: 4/11/2013 Samples Anelymd: 127
Federal Way High School-Block „-�” I
Project Loc.: C rtla;v 1
' Reviewed by: Steve Fan ao Zhan President
Analyzed by: Ryan Antotack ( Y ) 9•
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
3 White brittle None Filler, Binder, Paint 3 Cellulose
material with paint detected
1 Beige powdery None Binder/filler, Paint 4 Cellulose
material with paint detected
13 10527-C-13 Gray sandy/brittle None
2 material with detected Sand, Filler, Binder 6 Cellulose
fibrous material _
1 Beige powdery None Binder/filler, Paint 2 Cellulose
material with paint detected
Gray sandy/brittle None
14 10527-C-14 2 material with detected Sand, Filler, Binder 7 Cellulose
fibrous material
3 White chalky None Binder/filler, 26 Cellulose
d G
material with paper detected
Beige powdery None Binder/filler, Paint 2 Cellulose
material with paint detected
15 10527-C-15 Gray sandy/brittle None
2 material with detected Sand, Filler, Binder 5 Cellulose
fibrous material
1 White soft/elastic None Binder, Filler, Paint 2 Cellulose
material with paint detected
16 10527-C-16 2 Silver foil None Foil/binder None detected
detected _
3 Gray fibrous None Filler, Perlite 62 Cellulose
material detected
1 White sandy/brittle None Sand, Filler, 3 Cellulose
17 10527-C-17 material with paint detected Binder, Paint
2 White chalky None Binder/filler, 27 Cellulose
material with paper detected Gypsum/binder
1 White sandy/brittle None Sand, Filler, 4 Cellulose
18 1 D527-C-18 material with paint detected Binder, Paint
2 White chalky None Binder/filler, 36
Gypsum/binder Cellulose,
material with paper detectedypsum Glass fibers
White sandy/brittle None Sand, Filler, 3 Cellulose
19 10527-C-19 material with paint detected Binder, Paint
2 White chalky None Binder/filler, 34 Cellulose,
material with paper detected Gypsum/binder Glass fibers
1 Tan rubbery None Rubber/binder 2 Cellulose
material detected
2 Cream mastic None Mastic/binder 3 Cellulose
detected
20 10527-C-20
3 White sandy/brittle None Sand, Filler, 4 Cellulose
d Bi
material with paint detectender, Paint
4 White chalky None Binder/filler, 27 Cellulose
material with paper detected Gypsum/binder
Black foamy None Synthetic foam.
21 10527-C-21 1 material with2 Cellulose
detected Mastic/binder
mastic
None Vinyl/binder, 3 Cellulose
22 10527-C-22 1 Gray tile detected Mineral grains
2
• •
s •
SEATTLE AS EST'OS TEST NvL,,p A c adiwation Lab Coles.SeIie?tu -2d 0a73, L ynreow3-200765
- Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105,
Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tel:425.861,1111,Fax:425.861.1118 Tel:206.633.1111,Fax:206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/R-93/116
Mn.: Mr.Herb Brod client EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005
Job#: 10527-01r Batch#: 201310528 Date Received: 4/5/2013
Samples Recd: 127 Dabs Analyzed: 4/11/2013 samples Analyzed: 127
Federal Way High School-Block ,
Project Loc.: C ...,-L.Jaj
Analyzed by: RyPa`nrAntolock Reviewed by: Steve(Fanyao)Zhang,President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
2 Yellow mastic None Mastic/binder 4 Cellulose
detected
3 Gray brittle None Filler, Binder, Sand 5 Cellulose
material detected
4 Gray sandy/brittle None Sand, Filler, Binder 3 Cellulose
material detected
1 ' Blue tile None Vinyl/binder, 2 Cellulose
detected Mineral grains
23 10527-C-23 Yellow/black Mastic/binder,
2 mastic with brittle 3 Chrysotile Filler 4 Cellulose
material
1 Yellow/tan mastic dentected Mastic/binder 3 Cellulose
Gray brittle None
2 Filler, Binder 2 Cellulose
24 10527-C-24 material detected
3 Black tile 3 Chrysotile Vinyl/binder, 3 Cellulose
Mineral grains
4 Black mastic 3 Chrysotile Mastic/binder 4 Cellulose
1 Beige/green mastic None Mastic/binder, 5 Cellulose
with brittle material detected Filler
2 Yellow mastic None Mastic/binder 4 Cellulose
25 10527-C-25 detected
3 Gray brittle Norte Filler, Binder 2 Cellulose
material detected
4 Gray sandy/brittle None Sand, Filler, Binder 4 Cellulose
material detected
1 Yellow mastic deteected Mastic/binder 3 Cellulose
26 10527-C-262 Gray brittle None Filler, Binder, Sand 5 Cellulose
material detected
3 Black mastic 3 Chrysotile Mastic/binder 3 Cellulose
1 Gray ceramic None Ceramic/binder None detected
detected
one
2 Beige mastic dem Mastic/binder 4 Cellulose
27 10527-C-27 Light gray None
3 brittle/sandy detected Binder, Sand 2 Cellulose
material
Dark gray
4 sandy/brittle detected Sand, Filler, Binder 4 Cellulose
material
1 White ceramic d�tBGt� Ceramic/binder None detected
28 10527-C-28 2 Beige mastic d eected Mastic/binder 3 Cellulose
3 White brittle/sandy None Binder, Sand 2 Cellulose
material detected
3
• • ••
SEATTLE A:B EkT(:)S TEST IWv � ^ � 'rt.1trt^7 Lab Codas:Beile4FS-20£874;Ljlnwood-2;0788
Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105, -
Lynnwood,WA 98036,Tel:425.673,9850,Fax:425.673,9810 WA 98005,Tel:425.861.1111,Fax:425.861.1118 Tel:206.633.1111,Fax:206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/R-93/116
Ann.: Mr.Herb Brod Client EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005
Jobit: 10527-01r Batch* 201310528 Date Rees ved: 4/5/2013
Samples Redd: 127 Date Analyzed: 4/11/2013 samples Analyzed: 127
Federal Way High School-Block /1 `
Project Loc.: C �yyt.L"�v'r,"
Analyzed by. Ryan Antolock Reviewed by: Steve(Fanyao)Zhang,President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
Trace white None
4 powdery material detected Binder/filler, Paint 5 Cellulose
with paint
1 Beige/yellow mastic None Mastic/binder 3 Cellulose
detected
None Vinyl/binder, 2 Cellulose
29 10527-C-29 2 Off-white tile detected Mineral grains
3 Black mastic with 3 Chrysotile Mastic/binder 4 Cellulose
brittle material
1 Gray/beige sheet None Vinyl/binder None detected
vinyl detected
Brown fibrous None Binder/filler,
2 backing withdetected Mastic/binder 69 Cellulose
30 10527-C-30 mastic
3 Brown brittle None Filler, Binder 4 Cellulose
material detected
4 Trace black mastic 3 Chrysotile Mastic/binder 3 Cellulose
None Paint, Filler 2 Cellulose
1 Silver paint detected
31 10527-C-31 Gray/green None
2 soft/elastic detected Binder, Filler 3 Cellulose
material
1 White soft/elastic None Binder, Filler 4 Cellulose
material detected
32 10527-C-32 Trace gray/green None
2 soft/elastic detected Binder, Filler 2 Cellulose
material
33 10527-C-33 1 Black soft/elastic None Binder, Filler 3 Cellulose
material detected
Brown fibrous None
1 Filler, Paint 91 Cellulose
34 10527-C-34 material with paint detected
2 Brown mastic NOS Mastic/binder 6 Cellulose, Talc
detected
Blue woven fibrous None
1 Filler, Binder 84 Synthetic fibers
material detected
None
2 Yellow/brown masti detected Mastic/binder 3 Cellulose
35 10527-C-35 Gray brittle None
3material detected Filler, Binder, Sand 4 Cellulose
4 Black mastic with 3 Chrysotile Mastic/binder 3 Cellulose
brittle material -
1 Yellow/tan mastic None detected Mastic/binder 4 Cellulose
Gray brittle None
2 Filler, Binder 3 Cellulose
36 10527-C-36 material detected
3 Black tile 3 Chrysotile Vinyl/binder, 2 Cellulose
Mineral grains
4 Black mastic 3 Chrysotile Mastic/binder 4 Cellulose
4
r r • •
SEATTLE ASBESTOS TEST NV!.AP Accred toucan Lab Codes:Seltevue-200376,Lynnwood-200768
Lynnwood Laboratory,19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory 4500 9th Ave.NE.Suite 300,Seattle,WA 98105,
Lynnwood,WA 98036,Tel.425.673.9850,Fax 425.673.9810 WA 98005,Tel:425.861.1111,Fax:425.861.1118 Tel.206.633.1111.Fax 206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/12-93/116
Mn.: Mr.Herb Brod client: EHS International,Inc. Address: 13228 NE 20th St#100.Bellevue,WA 98005
Job 10527-01r Batch#: 201310528 Date Received: 4/5/2013
Samples Redd: 127 Date Analyzed: 4111/2013 Samples Analyzed: 127
Federal Way High School-Block 2 :" y'
Project Loc.: C /�J=qyr(::‘ ,6"
/.�.GY
Analyzed by. ♦cyan Antelocck,_ Reviewed by Steve(Fanyao)Zhang,President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
1 Beige powdery None Binder/filler, Paint 3 Cellulose
material with paint detected
37 10527-C-37 Gray sandy/brittle None
2 material with detected Sand, Filler, Binder 5 Cellulose
fibrous material
1 Beige powdery None Binder/filler, Paint 4 Cellulose
material with paint detected
38 10527-C-38 Gray sandy/brittle None
2 material with detected Sand, Filler, Binder 7 Cellulose
fibrous material
1 Beige powdery None Binder/filler, Paint 3 Cellulose
material with paint detected
39 10527-C-39 Gray sandy/brittle None
2 material with detected Sand, Filler, Binder 6 Cellulose
fibrous material
Yellow fibrous None
1 Filler, Glass beads 93 Glass fibers
40 10527-0-40 material detected
2 Yellow/tan mastic None Mastic/binder 3 Cellulose
detected
1 Orange/yellow shee None Vinyl/binder None detected
vinyl detected
Trace None Mastic/binder 2 Cellulose
41 10527-C-41 2 yellow mastic detected
3 Gray brittle None Filler, Binder, Sand 4 Cellulose
material detected
4 Trace black mastic 3 Chrysotile Mastic/binder 3 Cellulose
Tan soft material None Filler, Binder, Fine
42 10527-C-42 1 with fibrous detected particles, Debris 5 Cellulose
material and debris
1 Tan/gray fibrous None Filler 84 Cellulose
43 10527-C-43 material detected
2 Brown mastic None Mastic/binder 7 Cellulose, Talc
detected
1 Blue rubbery None Rubber/binder 2 Cellulose
material detected
2 Brown mastic None Mastic/binder 3 Cellulose
44 10527-C-44 detected
3 Beige mastic None Mastic/binder 2 Cellulose
detected
4 Brown wood debris None Wood debris 6 Cellulose
detected
1 Blue rubbery None Rubber/binder 2 Cellulose
material detected
one
45 10527-C-45 2 Yellow mastic d � Mastic/binder 3 Cellulose
3 etect
White powdery None Binder/filler, Paint 5 Cellulose
material with paint detected
46 10527-C-46 1 Beige powdery None Binder/filler, Paint 3 Cellulose
material with paint detected
5
• • >
SENITLE ASBESTOS T LEST `LA' Accreditation+_ab C,des:Be.!evu 200876,Lynnwood-200768
Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 96105, `
Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tel:425.861.1111,Fax 425.861.1118 Tel 206.633.1111,Fax:206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPN600/R-93/116
Ann.: Mr.Herb Brod Chant: EHS International,Inc. Address: 13228 NE 20th St*100,Bellevue,WA 98005
Job#: 10527-01r Batch* 201310528 Date Received: 4/5/2013
Samples Redd: 127 Data Andned: 4/11/2013 sa rples Analyzed: 127
Project Loc.:
Federal Way High School-Block "7,?,', /72/,
. �'.
Analyzed by. Ryan Antotock Reviewed by: Steve(Fanyao)Zhang,President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
Gray sandy/brittle
2 material with deed Sand, Filler, Binder 6 Cellulose
fibrous material
1 Beige powdery None Binder/filler, Paint 2 Cellulose
material with paint detected
47 10527-C-47 Gray sandy/brittle None
2 material with detected Sand, Filler, Binder 7 Cellulose
fibrous material
1 Beige powdery None Binder/filler, Paint 3 Cellulose
material with paint detected
48 10527-C-48 Gray sandy/brittle None
2 material with detected Sand, Filler, Binder 5 Cellulose
fibrous material
White sandy/brittle None Sand, Filler,
1 4 Cellulose
49 10527-C-49 material with paint detected Binder, Paint
White chalky None Binder/filler, Cellulose,
2 material with paper, detected Gypsum/binder 35 Glass fibers
1 White sandy/brittle None Sand, Filler, 3 Cellulose
50 10527-C-50 material with paint detected Binder, Paint
White chalky None Binder/filler, Cellulose,
2 material with paper detected Gypsum/binder 38 Glass fibers
White sandy/brittle
1 material with paint None Sand, Filler, 34 Cellulose,
51 10527-C-51 and woven fibrous detected Binder, Paint Glass fibers
material
2 White chalky None Binder/filler, 39 Cellulose,
material with paper detected Gypsum/binder Glass fibers
1 White sandy/brittle None Sand, Filler, 2 Cellulose
52 10527-C-52 material with paint detected Binder, Paint
White chalky None Binder/filler, Cellulose,
2 material with paper detected Gypsum/binder 41 Glass fibers
Brown chalky Binder/filler,
53 10527-C-53 1 material with paint None Gypsum/binder, 42 Cellulose,
and paper detected Paint Glass fibers
1 Off-white powdery None Binder/filler, Paint 5 Cellulose
54 10527-C-54 material with paint detected
2 White chalky None Binder/filler, 34 Cellulose,
material with paper detected Gypsum/binder Glass fibers
White chalky Binder/filler,
55 10527-C-55 1 material with paint None Gypsum/binder, 37 Cellulose,
and paper detected Paint Glass fibers
1 Off-white powdery None Binder/filler, Paint 5 Cellulose
56 10527-C-56 material with paint detected
Brown chalky None Binder/filler, Cellulose,
2 material with paper detected Gypsum/binder 38 Glass fibers
Brown chalky Binder/filler,
None Cellulose,
57 10527-C-57 1 material with paint detected Gypsum/binder, 40 Glass fibers
and paper Paint
58 10527-C-58 1 White powdery None Binder/filler, Paint 4 Cellulose
material with paint detected
6
. , • •
SEATTLE::ASBESTOS TEST P:ALAE k.,cTra,di,._ti:rt Lab Cedes:Be levee-200976,Lynnwood-200763
Lynnwood Labo atoyy 19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105,
Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tel:425.861.1111,Fax 425.861.1118 Tel:206.633.1111,Fax:206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/R-93/116
Attn.: Mr.Herb Brod cur* EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005
Jobe: 10527-01r Batdr#: 201310528 Date Received: 4/5/2013
Samples Recd: 127 Date Analyzed: 4/11/2013 samples Analyzed: 127
Federal Way High School-Block /f %)�j-
Project Lod.: C /: �{'6'�`
Analyzed by: Ryan Antolock Reviewed by: Steve(Fanyao)Znang,President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
White chalky None Binder/filler, Cellulose,
2 material with paper detected Gypsum/binder 36 Glass fibers
1 Tan/brown soft/elas None Binder, Filler 3 Cellulose
material detected
59 10527-C-59 Black soft/elastic None Cellulose,
2 material with detected Binder, Filler 7 Synthetic fibers
fibrous material
Off-white powdery None
60 10527-C-60 1 material with paint detected Binder/filler, Paint 3 Cellulose
Blue powdery None Filler, Fine
61 10527-C-61 1 material with detected particles 62 Synthetic fibers
fibrous material
Blue powdery None Filler, Fine
62 10527-C-62 1 material with detected particles 64 Synthetic fibers
fibrous material
Blue powdery None Filler, Fine
63 10527-C-63 1 material with detected particles 60 Synthetic fibers
fibrous material
1 White soft/elastic None Binder, Filler, Paint 4 Cellulose
64 10527-C-64 material with paint detected
2 Yellow fibrous None Filler, Glass beads 92 Glass fibers
material detected
Trace off-white None
65 10527-C-65 1 powdery material detected Binder/filler, Paint 3 Cellulose
with paint
Trace off-white None
66 10527-C-66 1 powdery material detected Binder/filler, Paint 2 Cellulose
with paint ,
67 10527-C-67 1 Gray fibrous None Paint, Filler, Perlite 65 Cellulose
material with paint detected
Brown fibrous
1 material with trace detected Filler, Paint 86 Cellulose
paint
68 10527-C-68 2 Brown mastic None Mastic/binder 6 Cellulose,Talc
detected
3 White chalky None Binder/filler, 24 Cellulose
material with paper detected Gypsum/binder
1 Beige powdery None Binder/filler, Paint 3 Cellulose
material with paint detected
Gray sandy/brittle None
69 10527-C-69 2 material with detected Sand, Filler, Binder 6 Cellulose
fibrous material
3 White chalky None Binder/filler, 24 Cellulose
material with paper detected _Gypsum/binder
1 Beige powdery None Binder/filler, Paint 2 Cellulose
material with paint detected
70 10527-C-70 Gray sandy/brittle
2 material with None
Sand, Filler, Binder 5 Cellulose
fibrous material
7
• •
SEATTLE ASBESTOS F:Oa r ST Nvi..'kP. ,c,e t rtlon Lab Codes:Bellevue-200876,Lywrood-2007€18
Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103. Bellevue Laboratory:12727 Northup Way.Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105,
Lynnwood,WA 98036,Tel:425.673.9850,Fax:425,673.9810 WA 98005,Tel:425.861.1111,Fax 425.861.1118 Tel:206.633.1111,Fax 206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPN600/R-93/116
Ann.: Mr.Herb Brod client EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005
Job# 10527-01r Batch*. 201310528 Date Received: 4/5/2013
Samples Redd: 127 Date Analyzed: 4/11/2013 sample.Analyzed: 127
Federal Way High School-Block e"`/ l
Project loc.: C Analyzed by: R jan Anlolock Reviewed by: Steve(Fanyao)Zhang,President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
1 White soft/elastic None Binder, Filler, Paint 2 Cellulose
material with paint detected
71 10527-C-71 2 Silver foil None Foil/binder None detected
detected
3 Gray fibrous None Filler, Perlite 63 Cellulose
material detected
1 Brown rigid/brittle None Filler, Binder 2 Cellulose
72 10527-C-72 material detected
2 Gray sandy/brittle None Sand, Filler, Binder 3 Cellulose
material detected
1 Gray sheet vinyl None Vinyl/binder None detected
detected
Gray fibrous None Binder/filler,
2 backing with detected Mastic/binder 68 Cellulose
73 10527-C-73 mastic
3 Black tile 3 Chrysotile Vinyl/binder, 3 Cellulose
Mineral grains
4 Black mastic 3 Chrysotile Mastic/binder 4 Cellulose
5 Brown wood block None Wood aggregates 5 Cellulose
detected
1 Off-white/gray tile None Vinyl/binder, 2 Cellulose
detected Mineral grains
2 Yellow mastic None
to acted Mastic/binder 4 Cellulose
74 10527-C-74 Gray brittle None Filler, Sand,
3 material with detected Mastic/binder 5 Cellulose
mastic
4 Black tile 3 Chrysotile Vinyl/binder, 2 Cellulose
Mineral grains
5 Black mastic 3 Chrysotile Mastic/binder 3 Cellulose
1 Beige powdery None Binder/filler, Paint 2 Cellulose
material with paint detected
75 10527-C-75 Gray sandy/brittle ^ None
2 material with detected Sand, Filler, Binder 7 Cellulose
fibrous material
76 10527-C-76 1 Yellow mastic with None Mastic/binder, 5 Cellulose
brittle material detected Filler, Sand
1 Yellow mastic with None Mastic/binder, 6 Cellulose
brittle material detected Filler, Sand
2 Red tile 3 Chrysotile Vinyl binder, 3 Cellulose
77 10527-C-77 Mineral grains
3 Black mastic 3 Chrysotile Mastic/binder 4 Cellulose
4 Brown wood block None Wood aggregates 5 Cellulose
detected
Yellow mastic with None Mastic/binder, Cellulose,
78 10527-C-78 1 fibrous material detected Filler 7 Synthetic fibers
2 Gray brittle None Filler, Binder, 3 Cellulose
material with paint detected Paint, Sand
8
. • •
e,^.
'1,�, T a; tA, s c� ES�+s`R S TEST VLAP Accr d t;.,ti<n Lab t tales: llevti e-M-73, ,it voc-2 D713
8
ter"rai3�. d `c.-,2 FA� ads��ie� ..6..
Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue Seattle
20Labb3 11 ,4500Fax:206 Ave.NE.Suite 300,Seattle,WA 98105,
Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005.Tel:425.861.1111,Fax:425.861.1116
7
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/R-93/116
Attn.: Mr.Herb Brod client: EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005
Job#: 10527-01r aster* 201310528 Date Received: 4/5/2013
Samples Recd: 127 DateMalyzed: 4/11/2013 Samples Analyzed: 127
ProlectLoc.: Federal Way High School-Block -
C "
Analyzed by: Ryan Antolock Reviewed by: Steve(Fanyao)Zhan9,President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
1 Yellow/brown None Mastic/binder 4 Cellulose
mastic detected
Black mastic with 2 Chrysotile Mastic/binder, 5 Cellulose
2 soft material Filler
3 Brown fibrous None Filler 86 Cellulose
79 10527-C-79 material detected
4 Clear/yellow brittle None Filler, Binder 2 Cellulose
material detected
5 Brown wood block None Wood aggregates 5 Cellulose
detected
6 Black asphaltic None Filler,Asphalt, 69 Cellulose
fibrous material detected Binder
Gray fibrous NoneFiller, Glass beads 72 Cellulose,
1 material detected Glass fibers
80 10527-C-80 None
2 Brown mastic detected Mastic/binder 6 Cellulose,Talc
Beige powdery None Binder/filler, Paint 2 Cellulose
1 material with paint detected
81 10527-C-81 Gray sandy/brittle None
2 material detected Sand, Filler, Binder 3 Cellulose
1 Beige powdery None Binder/filler, Paint 2 Cellulose
82 10527-C-82 material with paint detected
2 Gray sandy/brittle None Sand, Filler, Binder 4 Cellulose
material detected
Beige powdery None Binder/filler, Paint 3 Cellulose
1 material with paint detected
83 10527-C-83 Gray sandy/brittle None
2 material with detected Sand, Filler, Binder 7 Cellulose
fibrous material
10527-C-84 1 Off-white powdery 2 Chrysotile Binder/filler, Paint 4 Cellulose
84 material with paint
Composite2 Brown chalky None Binder/filler, 36
Cellulose,
result<1% material with paper Gypsum/binderdetected Glass fibers
85 10527-C-85 1 Brown chalky None Binder/filler, 34
Cellulose,
material with paper Gypsum/binderdetected Glass fibers
1 White sandy/brittle None Sand, Filler,d BiPaint
3 Cellulose
86 10527-C-86 material with paint detectender,
2 White chalky None Binder/filler, 38
Gm/binder Cellulose,
material with paper detectedypsuGlass fibers
Off-white/white None
1 powdery material detected Binder/filler, Paint 5 Cellulose
with paint
87 10527-C-87 White chalky Binder/filler,
None Cellulose,
2 material with paint detected Gypsum/binder, 42 Glass fibers
and paper Paint
1 Off-white powdery 2 Chrysotile Binder/filler, Paint 4 Cellulose
material with paint
88 10527-C-88 White chalky None Binder/filler, 33
Gum/binder Cellulose,
2 material with paper detectedypsGlass fibers
9
•
SEATTLE ASBESTOS TEST MILA9 AcCi ,di sSont Lab Codes:<siie a 200878,'ynnwoo. 2007€13
Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300.Seattle,WA 98105,
Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,TeL 425.861.1111,Fax:425.861.1118 Tel:206.633.1111,Fax:206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/R-93/116
Amt.: Mr.Herb Brod client: EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005
Jobe: 10527-01r wad* 201310528 Date Received: 4/5/2013
Samples Rec'd: 127 Date Analyzed: 4/11/2013 Samples Analyzed: 127
Federal Way High School-Block . °�y�' -
Project Loc.: c 17. /4,, X .
Analyzed by: Ryan Antolock Reviewed by: Steve(Fanyao)Zhang,President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
1 Tan rubbery None Rubber/binder 2 Cellulose
material detected
2 Cream mastic det�ete'ed Mastic/binder 3 Cellulose
89 10527-C-89 White/off-white
3 powdery material None Binder/filler, Paint 37 Cellulose
with paint and detected
paper
Asphalt/binder,
Black asphaltic
None Binder/filler, Fine
90 10527-C-90 1 fibrous material detected particles, Debris, 74 Cellulose
with debris Sand
Gray sandy/brittle
91 10527-C-91 1 material with None
to ectad Sand, Filler, Binder 6 Cellulose
fibrous material
1 Yellow/tan mastic None Mastic/binder 4 Cellulose
92 10527-C-92 detected
2 Brown fibrous None Filler 88 Cellulose
material detected
93 10527-C-93 1 Gray soft/elastic None Binder, Filler 3 Cellulose
material detected
Gray/green None
94 10527-C-94 1 soft/elastic detected Binder, Filler 4 Cellulose
material
Gray fibrousFiller, Fine
95 10527-C-95 1 material ``6 Chrysotile particles 32 Cellulose
96 10527-C-96 1 Black asphaltic 5 Chrysotile Asphalt/binder 3 Cellulose
material
97 10527-C-97 1 Black asphaltic None Filler,Asphalt, 67 Cellulose
fibrous material detected Binder
98 '10527-C-98 1 Tan paper with None Filler, 71 Cellulose
black mastic detected Asphaltic/binder
1 White woven None Binder/filler 82 Cellulose
99 10527-C-99 fibrous material detected
Gray fibrous Filler, Fine
2 material 55 Chrysotile particles 36 Cellulose
100 10527-C-100 1 Gray fibrous None Paint, Filler, Perlite 69 Cellulose
material with paint detected
1 Brown fibrous None Filler, Paint 92 Cellulose
material with paint detected
101 10527-C-101 2 Brown/black None Mastic/binder 7 Cellulose,Talc
mastic detected
3 White chalky None Binder/filler, 24 Cellulose
material with paper detected Gypsum/binder
White chalky None Binder/filler,
102 10527-C-102 1 material with paint detected Gypsum/binder, 35 Cellulose
and paper Paint
103 10527-C-103 1 Yellow mastic detected Mastic/binder 3 Cellulose
10
• • •
3 F^g'-'^,�' '!fi�xx TE T NVLAPA crttiSdY?LbCd ,-z�.;i�=`9t48.20i:8 b Y•ii`9oCd-2 ' B
Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Nortttup Way.Suite 1,Bellevue Seattle Laboratory 4500 9th Ave NE,Suite 300,Seattle,WA 98105.
Lynnwood,`NA 98036,Tel 425.673.9850,Fax:425.673.9810 WA 90005,Tel 425.861.1111,Fax:425.661.1118
Tel 206 633 1111 Fax 206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/R-93/116
Amt: Mr.Herb Brod talentEHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005
Job*: 10527-01 r
Batch*. 201310528 Date Received: 415/2013
Samples Recd: 127Date analyzed: 4/11/2013 samples Analyzed: 127
Federal Way High School-Block
Project Loc.: •
f,.
Analyzed by: Ryan Antolock Reviewed by: Steve(Fanyao)Zhang,President
Lab ID Client Sample ID Layer Descri•
ption % Asbestos Fibers Non-fibrous Components % Non asbestos Fibers
2 Gray the 2 Chrysotile Vinyl/binder, 2 Cellulose
Mineral grains
3 Black mastic 2 Chrysotile Mastic/binder 4Cellulose
4 Brown wood debris None Wood debris 7Cellulose
detected
Yellow/black None
1 Mastic/binder 4 Cellulose
104 10527-C-104 mastic detected
None
2 Brown wood debris detected Wood debris 6 Cellulose
1 Gray rubbery None Rubber/binder 2Cellulose
material detected
105 10527-C-105 2 Cream mastic detected Mastidbinder 3 Cellulose
Brown mastic with None Mastic/binder, 27 Cellulose,Talc
paint and paper detected Filler, Paint
White chalky None Binder/filler, Cellulose,
106 10527-C-106 1 material with paint detected Gypsum/binder, 38 Glass fibers
andpaper Paint
1 White sandy/brittle None Sand, Filler, 4 Cellulose
107 10527-C-107 material with paint detected Binder, Paint
2 White chalky None Binder/filler, 36 Cellulose,
material with paper detected Gypsum/binder Glass fibers
10527-C-108 1 Off-white powdery 2 Chrysotile Binder/filler, Paint 5 Cellulose
108 material with paint
Composite2 White chalky None Binder/filler, 27 Cellulose
result<1% material with paper detected Gpsum/binder
1 Tan rubbery None Rubber/binder 2 Cellulose
109 10527-C-109 material detected
Brown mastic with None
2 Mastic/binder 26 Cellulose,Talc
paint and paper detected
1 White powdery None Binder/filler, Paint 5 Cellulose
110 10527-C-110 material with paint detected
2 White/pink chalky None Binder/filler, 34 Cellulose,
material with paper detected Gypsum/binder Glass fibers
White chalky None Binder/filler, Cellulose,
111 10527-C-111 1 material with paint detected Gypsum/binder, 40 Glass fibers
and paper Paint
White sandy/brittle
1 material with paint None Sand, Filler, 26 Cellulose,
112 10527-C 112 and woven fibrous detected Binder, Paint Glass fibers
material
2 White chalky None Binder/filler, 32 Cellulose,
material with paper detected Gypsum/binder Glass fibers
Trace white None
1 powdery material detected Binder/filler, Paint 3 Cellulose
with paint
113 10527-C-1132 White sandy/brittle None Sand, Filler, Binder 4 Cellulose
material detected
White chalky None Binder/filler, 37 Cellulose,
material with paper detected Gypsum/binder Glass fibers
11
•
SEATTLE ASBESTOS TEST MILAP Accreditation Lail Codes.Be Levu&200876,Lynnwood-200768
Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105, •
Lynnwood,WA 98036.Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tel:425.861.1111,Fax:425.861.1118 Tel:206.633.1111,Fax:206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPN600/R-93/116
Attn.: Mr.Herb Brod orient: EHS International,Inc. Addresx 13228 NE 20th St#100,Bellevue,WA 98005
Job#: 10527-01r Batch#: 201310528 owe Received: 4/5/2013
Samples Recd: 127 Bate Analyzed: 4/11/2013 Samples Analyzed: 127
Federal Way High School-Block /'�,
Project Loc.: C jrw(10t4"-
Analyzed by: Ryan Antolock Reviewed by: Steve(Fanyao)Zhang,President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
1 Brown fibrous None Filler, Paint 89 Cellulose
material with paint detected
114 10527-C-114 2 Brown mastic None Mastic/binder 6 Cellulose,Talc
detected
3 White chalky None Binder/filler, 35 Cellulose,
material with paper detected Gypsum/binder Glass fibers
115 10527-C-115 1 Gray fibrous None Paint, Filler, Perlite 64 Cellulose
material with paint detected
1 Gray sheet vinyl None Vinyl/binder None detected
detected .
Beige fibrous None Binder/filler,
116 10527-C-116 2 backing with detected Mastic/binder68 Cellulose
mastic
3 Black mastic with None Mastic/binder, 6 Cellulose
brittle material detected Sand
1 Off-white/gray tile None Vinyl/binder, 2 Cellulose
detected Mineral grains
117 10527-C-117 2 Yellow mastic None Mastic/binder 3 Cellulose
detected
3 Black mastic with 3 Chrysotile Mastidbinder, 8 Cellulose
brittle material Filler, Sand
1 White sandy/brittle None Sand, Filler, 3 Cellulose
118 10527-C-118 material with paint detected Binder, Paint
2 White chalky None Binder/filler, 31 Cellulose,
material with paper detected Gypsum/binder Glass fibers
White powdery None
1 material with paint detected Binder/filler, Paint 34 Cellulose
119 10527-C-119 and paper
2 White chalky None Binder/filler, 37 Cellulose,
material with paper detected Gypsum/binder Glass fibers
White powdery None
1 Binder/filler, Paint 4 Cellulose
120 10527-C-120 material with paint detected
2 White chalky None Binder/filler, 36 Cellulose,
material with paper detected Gypsum/binder Glass fibers
Trace white None
1 powdery material Binder/filler, Paint 3 Cellulose
with paint detected
121 10527-C-1212 Brown fibrous None Filler 91 Cellulose
material detected
3 Brown mastic None Mastic/binder 7 Cellulose,Talc
detected
1 Yellow mastic None Mastic/binder 3 Cellulose
detected
122 10527-C-122 2 Off-white tile 2 Chrysotile Vinyl/binder, 2 Cellulose
Mineral grains
3 Black mastic 3 Chrysotile Mastic/binder 4 Cellulose
1 Yellow mastic None Mastic../binder 3 Cellulose
123 10527-C-123 detected
2 Gray brittle None Filler, Binder, Sand 5 Cellulose
material detected
12
. 4 •
. . AEST S sE a•
Nvi,„„A,pAccreditation Lab Codes:BRs'Isa ut 200878,Lynnwood-200708
Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:45009th Ave.NE,Suite 300,Seattle,WA 98105,
Lynnwood,WA 98036,Tel:425.673.9850,Fax 425.673.9810 WA 98005,Tel:425.861.1111,Fax:425.861.1118 Tel:206.633.1111,Fax:206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/R-93/116
Amt.: Mr.Herb Brod alene EHS International,Inc. Address: 13228 NE 20th St*100,Bellevue,WA 98005
Job#: 10527-01r Batch*: 201310528 Date Received: 4/5/2013
Samples Recd: 127 Date Analyzed: 4/11/2013Samples Analyzed: 127
Federal Way High School-Block 77X
Proiect Loc.: C
Analyzed by:RI(an Antolock Reviewed by: Steve(Fanyao)Zhang,President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
1 Yellow mastic None Mastic/binder 2 Cellulose
detected
124 10527-C-124 2 Gray tile 3 Chrysotile Vinyl binder, 3 Cellulose
Mineral grains
3 Black mastic 3 Chrysotile Mastic/binder 4 Cellulose
1 Yellow mastic None Mastic/binder 2 Cellulose
detected
125 10527-C-1252 Gray brittle None Filler, Binder, Sand 5 Cellulose
material detected
3 Trace black mastic 3 Chrysotile Mastic/binder 3 Cellulose
126 10527-C-126 1 White soft/loose None Filler, Fine 6 Cellulose
material detected particles
1 Yellow mastic None Mastic/binder 3 Cellulose
detected
127 10527-C-127 2 Off-white tileNone Vinyl/binder, 2 Cellulose
detected Mineral grains
3 Yellow mastic None Mastic/binder 4 Cellulose
detected
13
• •
SEATTLE ASBESTOS TEST NVLAP Accreditation Lab Codes:200768 and 200876
19711 Scriber Lake Road,Suite D,Lynnwood,WA 98036,Te1:425.673.9850,Fax:425.673.9810
12727 Northup Way,Suite 1,Bellevue,WA 98005,Tel:425.861.1111,Fax:425.861.111 B
Website:www.seattleasbestostest.com,Email:admin@seattleasbestostestcom
PLM by Point Count(400 Points)
Client Job#: 10527-01r
Attention: Mr.Herb Brod Laboratory Batch#: 201310868
Client: EHS International,Inc. Date Received: 4/22/2013
Address: 13228 NE 20th St#100,Bellevue,WA 98005 Samples Received: 3
Date Analyzed: 4/2412013
Project: Federal Way High School-Block G
Sample Requested for Point Count 10527-C-84
Previous Analytical Information
Previously Analyzed by: Ryan Antolock
Previous Batch#: 201310528
Previous Lab ID: 84
Previous Description: Off-white powdery material with paint
Layer to be Point Counted: 1
Asbestos Type Found: Chrysotile
Asbestos Percentage Found: 2
Point Count Analytical Procedures New Lab ID: 1
Asbestos Points Non-Asbestos Points Total Points Counted
Slide 1 0 50 50
Slide 2 0 50 50
Slide 3 0 50 50
Slide 4 0 50 50
Slide 5 0 50 50
Slide 6 1 49 50
Slide 7 0 50 50
Slide 8 0 50 50
Total 1 399 400
Point Count Summary Results
Type of Asbestos: Chrysotile
Percentage of Asbestos: 0.25%
Analyzed y: Ryan Antolock Reviewed by: Steve(Fanyao)Zhang, President
1
. . • •
SEATTLE ASBESTOS TEST NVLAP Accreditation Lab Codes:200768 and 200876
19711 Scriber Lake Road,Suite D.Lynnwood,WA 98036,Te1:425.673.9850,Fax:425.673.9810
12727 Northup Way,Suite 1,Bellevue,WA 98005,Te1:425.861.1111,Fax:425.861.1118
Website:www.seattleasbestostestcom,Email:admin@seattleasbestostest.com
PLM by Point Count(400 Points)
Client Job#: 10527-01 r
Attention: Mr.Herb Brod Laboratory Batch#: 201310868
Client EHS International,Inc. Date Received: 4/22/2013
Address: 13228 NE 20th St#100,Bellevue,WA 98005 Samples Received: 3
Date Analyzed: 4/24/2013
Project: Federal Way High School-Block C
Sample Requested for Point Count 10527-C-88
Previous Analytical Information
Previously Analyzed by: Ryan Antolock
Previous Batch#: 201310528
Previous Lab ID: 88
Previous Description: Off-white powdery material with paint
Layer to be Point Counted: 1
Asbestos Type Found: Chrysotile
Asbestos Percentage Found: 2
Point Count Analytical Procedures New Lab ID: 2
Asbestos Points Non-Asbestos Points Total Points Counted
Slide 1 0 50 50
Slide 2 _ 0 50 50
Slide 3 0 50 50
Slide 4 0 50 50
Slide 5 1 49 50
Slide 6 0 50 50
Slide 7 0 50 50
Slide 8 1 49 50
Total 2 398 400
Point Count Summary Results
Type of Asbestos: Chrysotile
Percentage of Asbestos: 0.5%
'
Analyzed By: Ryan Antolock Reviewed by: Steve(Fanyao)Zhang,President
2
! •
SEATTLE ASBESTOS TEST NVLAP Accreditation Lab Codes:200768 and 200876
19711 Scriber Lake Road,Suite D,Lynnwood,WA 98036,TeI:425.673.9850,Fax.425.673.9810
12727 Northup Way,Suite 1,Bellevue,WA 98005,Tel:425.861.1111,Fax:425.861.1118
Website:www.seattleasbestostestcom,Email:admin@seattleasbestostestcom
PLM by Point Count(400 Points)
Client Job#: 10527-01r
Attention: Mr.Herb Brod Laboratory Batch#: 201310868
Client: EHS International,Inc. Date Received: 4/2212013
Address: 13228 NE 20th St#100,Bellevue,WA 98005 Samples Received: 3
Date Analyzed: 4/24/2013
Project: Federal Way High School-Block C
Sample Requested for Point Count 10527-C-108
Previous Analytical Information
Previously Analyzed by: Ryan Antolock
Previous Batch#: 201310528
Previous Lab ID: 108
Previous Description: Off-white powdery material with paint
Layer to be Point Counted: 1
Asbestos Type Found: Chrysotile
Asbestos Percentage Found: 2
Point Count Analytical Procedures New Lab ID: 3
Asbestos Points Non-Asbestos Points Total Points Counted
Slide 1 0 50 50
Slide 2 1 49 50
Slide 3 0 50 50
Slide 4 1 49 50
Slide 5 0 50 50
Slide 6 0 50 50
Slide 7 0 50 50
Slide 8 1 49 50
Total 3 397 400
Point Count Summary Results
Type of Asbestos: Chrysotile
Percentage of Asbestos: 0.75%
Analyzed'By: Ryan Antolock Reviewed by: Steve(Fanyao)Zhang,President
3
• •
SEATTLE ASBESTOS TEST Lab 200878,Lynnwood-2007f
Lynwood Litman 19701 Salter Lees Rasa.Sole 103. Bellevue taccratory 12727 Nolan V18y.Sine 1.Bellevue. Seattle Laboratory 4500 Sri Ave.NE.Sia 300,Swale,WA 96105.
Lynwood,Vai 90036,1el;425..673.5650.Far 425.673.9810 WA.99005 Tei-425.861.1111,Far 425.861.1118 Td 206.633.1111,Far 206.633.4747
ANALYTICAL LABORATORY REPORT
PEM by Method EPA/600/R-93/116
Ada.: Mr.Herb Brod alert EHS International,Inc. A63esc 13228 NE 20th St#100,Bellevue,WA 98005
,Jobs: 10527-01r awe* 201310552 bate Receivat 4/8/2013
Samples Reda 45 Delo Analyzed 4/12/2013 SamplesAndyad: 45
n- Federal Way High School,Block f -�-_ '—._ _——"___„
Analyzed ty Liz Dutton Reveew e8 5r Steve(Farryae}Zr,a'g,P-eadeaa
Lab ID Client Sample€D Layer Description % Asbestos Fters Non-librous Components 96 Non-asbestos Fibers
1 Tan rubbery None Rubber/binder 2 Cellulose
material detected
one
1 10527-D-01 2 Tan mastic d ed Mastic/binder 3 Cellulose
None
3 Brown mastic Mastic/binder 5 Talc, Cellulose
1 Blue woven fibrous None Filler. Binder 85 Synthetic fibers
material detected
None
2 10527-D-02 2 Yellow/tan masticdetectedMastic/binder 4 Cellulose
3 Black mastic 3 Chrysotile Mastic/binder 6 Cellulose
Tan fibrous
one
1 material with white d Paint, Filler 92 Cellulose
etected
paint
3 10527-D-03 2 Dark brown mastic detected Mastic/binder 3 Cellulose, Talc
3 Pink chalky None Binder/filler, 25 Cellulose,
material with paper detected Gypsum/binder Glass fibers
4 10527-D-04 1 White fibrous 65 Chrysotile Filler, Fine 25 Cellulose
material particles
None
1 Silver paint detectedPaint, Filler 4 Cellulose
5 10527-0-05 Blade asphaltic
1 materia! 5 Chrysotile Asphalt/binder 3 Cellulose
1 Blue woven fibrous None Filler, Binder 89 Synthetic fibers
material detected
on
6 10527-D-06 2 Yellow/tan mastic defecated Mastic/binder 3 Cellulose
3 Black mastic 3 Chrysotile Mastic/binder 5 Cellulose
Gray None
1 material foamy detected Synthetic foam None detected
e
2 Clear mastic de Mastic/binder 4 Cellulose
7 10527-D-073 Off-white/brown/ None Vinyl/binder, 2 Cellulose
yellow/white tile detected Mineral grains
4 Yellow mastic Deeded Mastic/binder 4 Cellulose
5 Black mastic 3 Chrysotile Mastic/binder 4 Cellulose
1 Trace blue woven None Filler, Binder 89 Synthetic fibers
fibrous material detected
None
8 10527-D-08 2 Yellow/tan mastic Mastic/binder 3 Cellulose
,detected
3 Black mastic 3 Chrysotile Mastic/binder 5 Cellulose
4 White brittle None Filler. Binder 3 Cellulose
material Detected
Green/gray soft None
9 10527-D-09 1 material detected Filler. Binder 3 Cellulose
1
• , r ei
SEATTLE ASBESTOS TEST NVLAP Accreditation Lab 200878,Lynn
Lynnwood laboratory:19701 Saiber Lake Road,Suite 103. Bellevue Laboratory:12727 Noilbup Way,Suite 1,Bdewe, Seattle Laboratory:4500 901 Ave.NE,Stile 300,Seattle.WA 98105, k
Lynnwood,WA 98036,Tel:425.573.9850.Fax:425.673.9810 WA 98005.Tel:425.861.1111,Fax:425.861.1118 Tel:206.633.1111,Fax:206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA1600/R-937116
Aron: Mr.Herb Brod client EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005
Job*: 10527-01 r Bald*: 201310552 Date Received: 4/8/2013
Samples Recd 45 Date Anal md: 4/12/2013 sa 09lea Andyred: 45
Federal Way High School,Block ------��'��'__-.... —
Project Loc.: D — .
T�
Analyzed by Liz Dutton Reviewed by: Steve(Fanyao)Zhang,President
Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
10 10527-D-10 1 White soft/loose None Filler, Fine 7 Cellulose
material detected particles
Paint, Filler,
Gray fibrous None Cellulose,
11 10527-D-11 1 material with paint detected Perlite, Glass 68 Glass fibers
beads
Tan fibrous
1 material with white None detected Paint, Filler 90 Cellulose
paint
12 10527-D-12 2 Dark brown mastic None Mastic/binder 4 Cellulose, Talc
detected
White chalky None Binder/filler, Cellulose,
3 material with paper detected Gypsum/binder 21 Glass fibers
1 Gray brittle None Mastic/binder 4 Cellulose,Talc
material detected
Trace brown None
2 Mastic/binder 4 Cellulose, Talc
mastic detected
13 10527-D-13 3 Orange mastic de Mastic/binder 4 Cellulose,Talc
ted
4 Tan/white/brown tilE 2 Chrysotile Vinyl/binder, 2 Cellulose
Mineral grains
5 Black mastic 3 Chrysotile Mastic/binder 4 Cellulose
1 Gray rubbery None Rubber/binder, 2 Cellulose
material with paint detected Paint
14 10527-D-14 2 Creme mastic None Mastic/binder 3 Cellulose
detected
3 Brown mastic dented Mastic/binder 5 Talc, Cellulose
1 Black rubbery None Rubber/binder, 2 Cellulose
15 10527-D-15 material with paint detected Paint
2 Creme mastic with None Mastic/binder, 29 Cellulose
paint and paper detected Paint, Filler
White chalky Binder/filler,
16 10527-D-16 1 material with paint None Gypsum/binder, 36 Cellulose,
and paper detected Paint Glass fibers
1 White powdery None Binder/filler 5 Cellulose
material detected
17 10527-D-17 White chalky Binder/filler,
2 material with paint None Gypsum/binder, 37 Cellulose,
and paper detected Paint Glass fibers
White powdery None
1 Binder/filler, Paint 3 Cellulose
18 10527-D-18 material with paint detected
2 White chalky None Binder/filler, 24 Cellulose,
material with paper detected Gypsum/binder Glass fibers
10527-D-19 1 White powdery 2 Chrysotile Binder/filler, Paint 5 Cellulose
19 material with paint
Composite2 White chalky None Binder/filler, 25 Cellulose,
result<1% material with paper detected Gypsum/binder Glass fibers
2
• •
a
SEATTLE ASBESTOS TEST NVtAP Accr,:
Lynnwood Laboratory 19701 Sather Lake Road Sudo 103. Betiewe Laboratory:12727 Nanbup Way,Sure 1,13dewe, Seattle Laboratory:4500 9th Ave.NE.Suite 300.Searde.'NA.98105.
s Lynnwood,WA 98036,Tet:425.673.9850,Fax:425.6739810 WA 98006,Tet:425.861.1111,Fax 425.861.1118 Tet 206.6331111,Fax 206.633.4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPA/600/R-931116
Amt.: Mr.Herb Brod caent EHS International,Inc. Address: 13228 NE 20th St*100,Bellevue,WA 98005
Jotdi: 10527-01r 9atom 201310552 Date Received: 4/3/2013
Samples Redd: 45 Date analyzed: 4/12/2013 Samples Analyzed: 45
Project Loc.: Federal Way High School,Block
_-----....)
DCS�'}
Analyzed by: Liz Dutton Reviewed by Steve Fanyao Mang.ores:dent
Lab ID Client Sample IC) Layer Description % Asbestos Rows Non-fbrous Components % Non-asbestos Fibers
Pink chalky Binder�ller,
20 10527-0-20 1 material with paint None Gypsum/binder, 35 Cellulose,
and paper detected Paint Glass fibers
White brittle None
1 Filler, Binder, Paint 2 Cellulose
21 10527-D-21 material with paint detected
2 White brittle None Sand, Filler. 4 Cellulose
material with sand detected Binder, Perlite
1 White powdery 2 Chrysotile Binder/filler, Paint 5 Cellulose
22 10527-D-22 material with paint
2 Gray sandy/brittle None Sand, Filler. 3 Cellulose
material with paint detected Binder, Paint
23 10527-D-23 1 Gray sandy/brittle None Sand, Filler, 3 Cellulose
material with paint detected Binder, Paint
1 White powdery None Binder/filler, Paint 5 Cellulose
10527-0-24 material with paint detected
24 2 White powdery 2 Chrysotile Binder/filler, Paint 2 Cellulose
material with paint
Composite 3 Light pink chalky None Binder/filler, 24 Cellulose,
result<1% material with paper detected Gypsum/binder Glass fibers
10527-0-25 1 White powdery 2 Chrysotile Binder/filler, Paint 5 Cellulose
25 material with paint
Composite2 Light pink chalky None Binder/filler, 25 Cellulose,
result<1% material with paper detected Gypsum/binder Glass fibers
White chalky Binder/filler,
None Cellulose,
26 10527-0-26 1 material with paint detected Gypsum/binder, 35 Glass fibers
and paper Paint
1 Beige ceramic ducted Ceramic/binder None detected
2 White brittle None Binder 4 Cellulose
27 10527-0-27 material detected
3 Yellow mastic None Mastic/binder 5 Cellulose
detected
4 White powdery 2 Chrysotile Binder/filler 3 Cellulose
material
Gray fibrous None Paint, Filler, Glass Glass fibers,
1 material with white detected beads 65 Cellulose
paint
28 10527-0-28 2 Brown mastic duel Mastic/binder 3 Cellulose
3 White powdery None Binder/filler 35 Cellulose
material with paper detected
4 White chalky None Binder/filler, 25 Cellulose
material with paper detected Gypsum/binder
1 White powdery 2 Chrysotile Binder/filler 4 Cellulose
material
29 10527-D-29 2 White paper None Binder/filler 79 Cellulose
detected
3 White powdery 2 Chrysotile Binder/filler 34 Cellulose
material with paper
3
• r
•
SEATTLE ASBESTOS TEST .abCodex Belevue400.76,Lynnwood-200M
Lyrarwood Laboratory 19701 Saltier Lace Road,Stile 103, Be9evue Latxoratary,12727 Narttaxa Way,Suite 1,3caenue, Seattle Laboratory.4500 9th Ave.NE.Suite 300.Seattle,WA 98105,
Lynnwood,WA 96035,Tat 425.673.9850,Fax 425.673.9810 WA 96005..Tet 425.861.1111,Fax 425.861.1118 Tet:2E6.833.1111,Far:206.633.4747
ANALYTICAL LABORATORY REPORT
PIM by Method EPA/600/R-93/116
Ain: Mr.Herb Brod cunt EHS International.Inc. Address 13228 NE 20th St#100,Bellevue,WA 98005
Jobst: 10527-01r saat# 2 01 31 0552 Date Receivecd 4/8/2013
samples Reed: 45 Date Analyzed: 4/1212013 Senates Analyzed: 45
ProjectLam: Federal Way High School,Block
by:
icdLiz Neon Reviewed by Steve(Farryrao)Zhang,President
Lab ID Client Sample ID Layer Desaiption % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers
Composite White chalky None Binder/filler,
result<1% 4 material with paper detected Gypsum/binder 25 Cellulose
Gray fibrous None Paint, Filler, Glass Glass fibers,
1 material with white detected beads 65 Cellulose
30 10527-D-30 paint
one
2 Brown mastic d Mastic/binder 3 Cellulose
1 etected
Tan rubbery None Rubber/binder 4 Cellulose
material detected
31 10527-0-31 2 Creme mastic detected Mastic/binder 3 Cellulose
3 Brown mastic dtteonded Mastic/binder 6 Talc, Cellulose
1 Blue woven fibrous None Filler, Binder 85 Synthetic fibers
material detected
32 10527-0-32 2 Yellow mastic d�e
eted Mastic/binder 7 Cellulose
3 Dark gray mastic deteonr ed Mastic/binder 5 Cellulose
1 Yellow mastic NdMastic/binder Mastic/binder 6 Cellulose
White loose brittle None
2 Filler, Binder 7 Cellulose
33 10527-D-33 material detected
Trace gray
None
3 sandy/brittle Binder, Filler 5 Cellulose
detected
material
None
1 Yellow mastic Mastic/binder 5 Cellulose
detected
one
34 10527-D-34 2 Dark gray mastic d Mastic/binder 4 Cellulose
3 etected
Gray sandy/brittle None Binder, Filler 5 Cellulose
material detected
1 Light gray rubbery None Rubber/binder, 2 Cellulose
material with paint detected Paint
Non35 10527-D-35 2 White mastic dtected Mastic/binder 2 Cellulose
3 White powdery None Binder/filler, Paint 3 Cellulose
material with paint detected
1 Gray foamy None Synthetic foam None detected
material detected
36 10527-D-36 2 Clear/yellow None Mastic/binder 4 Cellulose
mastic detected
3 Black mastic 3 Chrysotile Mastic/binder 5 Cellulose
1 Black foamy None Synthetic foam None detected
37 10527-D-37 material detected
2 Beige mastic dad Mastic/binder 3 Cellulose
4
4, • S
SEATTLE ASBESTOS TEST NVLAP Accreditation Lab Codes:l3 8,L. 2007
Lyrnaood Leaman:19701 Saber Lek Road Suds 103, BeIeaee Laboratory-12727 iior5a4 Way,Stole 1,Bele%ue, SeaNte Laboratory.4500901 Ave_NE,Sale 300,Seattle.We 96105,
Lynwood,WA 98636,Td 425.673,9650,Far 425.6719810 WA 98005. el_425.851.1111,Fax 425.861.1118 7e1:205,633.1111,Fax 206.633,4747
ANALYTICAL LABORATORY REPORT
PLM by Method EPAI600/R-93/11 s
M: Mr.Herb Brod csent ENS International,Inc_ Address: 13228 NE 20th St#100,Bellevue,WA 98005
Job,: 10527-01r sestet 201310552 pee Received 4/8/2013
Samples Recd: 45 Daae autyeet 4/12/2013 Sernpiac Analyzed 45
Rcjxt Lac: Federal Way High School,Block __ X
Analyzed by L b orison Reviewed by. Steve(Fanyao)Zana.1 resder9
Lab ID Client Sample ID Layer Description % Asbestos Fliers Non-fibrous Components % Non-asbestos Fibers
White chalky None Binder/filler, Cellulose,
38 10527-D-38 1 material with paint detected Gypsum/binder. 32 Glass fibers
and paper Paint
White chalky! None Binder/filler, Cellulose,
39 10527-D-39 1 material with paint detected Gypsum/binder. 35 Glass fibers
and paper Paint
1 White powdery None Binder/filler, Paint 4 Cellulose
40 10527-D40 material with paint detected
2 White chalky None Binder/filler, 23 Cellulose,
material with paper detected Gypsum/binder Glass fibers
1 White powdery None Binder/filler, Paint 3 Cellulose
10527-D-41 material with paint detected
41 2 White powdery 2 Chrysotile Binder/filler, Paint 2 Cellulose
material with paint
Composite White chalky None Binder/filler, Cellulose,
result<1% 3 material with paper detected Gypsum/binder 26 Glass fibers
White powdery
1 material with paint Nde led Binder/filler, Paint 34 Cellulose
42 10527-D-42 and paper
2 White chalky None Binder/filler, Cellulose,
material with paper detected Gypsum/binder 25 Glass fibers
43 10527-D d3 1 Black soft/loose Filler, Fine
material 2 Chrysotile particles 5 Cellulose
Black foamy None Synthetic foam,
44 10527-D-44 1 material with clear None detected
mastic detected Mastic/binder
1 Gray soft/elastic Nolte Binder, Filler, Paint 4 Cellulose
material with paint detected
45 10527-0-45
2 Red brittle material de Rtected Filler, Binder 2 Cellulose
Trace gray
on3 sandy/brittle deteected Sand, Filler, Binder 3 Cellulose
material
5
•
! i e` b
SEATTLE ASBESTOS TEST rdvLAP Accreditation Lab codes 2007&3 and 2036
75
19711 Scriber Lake Road,Suite D,Lynnwood,WA 98036,Te1:425.673.9850.Fax:425.673.9810
12727 Northup Way,Suite 1.Bellevue,WA 98005,TeL Fax:425.861.1118
Website:www.seattleasbestostest.com,Email:admin@seattleasbestostesLcom
PLM by Point Count(400 Points)
Client Job#: 10527-01r
Laboratory Batch#: 201310973
Attention: Mr.Herb Brod Date Received: 4!25/2013
Client: EHS International,Inc. Samples Received: 1
Address: 13228 NE 20th St#100,Bellevue,WA 98005 Date Analyzed: 4/29/2013
Project Federal Way High School,Block D
Sample Requested for Point Count 10527-D-19
Previous Analytical Information
Previously Analyzed by: Liz Dutton
Previous Batch#: 201310552
Previous Lab ID: 19
Previous Description: White powdery material with paint
Layer to be Point Counted: 1
Asbestos Type Found: Chrysotile
Asbestos Percentage Found: 2
Point Count Analytical Procedures New Lab ID: 1
Counted
Asbestos Points Non-Asbestos Points Total Points50
Slide 1 0 50
50 50
Slide 2 0 50
Slide 3 0 50
Slide 4 0 50 5050
Slide 5 1 59 50
Slide 6 0 50
50
Slide 7 1 49
Slide 8 0 50 50400
Total , 2 398
Point Count Summary Results
Type of Asbestos: Chrysotile
Percentage of Asbestos: 0.5%
Analyzed By: Liz Dutton Reviewed by: Steve(Fanyao)Zhang:President
;_--7-1.7-7:22_-_ ,..------
---..
1