21-100549-Plan Set-05-11-2021-V2Municipal Approval Stamps T1-01 TITLE SHEET G1-01 PROJECT INFO, SYMBOLS & CODE ANALYSIS G1-02 GENERAL NOTES & ABBREVIATIONS G1-03 GENERAL NOTE G1-10 ACCESSIBILITY DETAILS ARCHITECTURAL A2-11 DIMENSIONED FLOOR PLAN A2-13 FINISH & EQUIPMENT PLAN A2-14 REFLECTED CEILING PLAN CLIENT TODD MARTINSON tmartinson@yahoo.com 253 973 3645 ARCHITECT DXU, LLC. 404 S. WELLS STREET CHICAGO, IL 60607 P: 312 955 0334 CONTACT: JEREMY WILMOT 14f .r Stgn arama w V I v �p E�r FOL 17 Nvol EVE. % SIGNARAMA 1414 S. 324TH ST. SUITE B201 FEDERAL WAY, WA 98003 INDEX OF DRAWINGS CONTACTS MECH, ELECT & PLUMB ENGINEER AEDIFICA CASE ENGINEERING 796 MERUS CT FENTON, MO 63026 P: 636 349 1600 EXT.227 CONTACT: ENGINEER: LINDSEY WINGRON SUB -CONTRACTORS BUILDING DEPARTMENT LYNNWOOD WASHINGTON DEVELOPMENT AND BUSINESS SERVICES 20816 44TH AVE W. STE 230 PO BOX 5008 LYNNWOOD, WASHINGTON 98046-5008 P: 425 670 5400 1 E0.01 ELECTRICAL SPECIFICATIONS E1.01 ELECTRICAL POWER PLAN E2.01 ELECTRICAL LIGHTING PLAN SPRINKLER: YES FIRE ALARM: NO RESUBMITTED May 12 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT IrrSfg►rarama Client THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. SIGNARAMA 1414 S. 324TH ST. STE B201 FEDERAL WAY, WA Project LJ FP1 PCHITECTS 412 S. Wells Street , 2nd Floor � Chicago , IL - 60607 P:3129550334 L dxuarch.com Architect of Record Consultant 1 CITY COMMENTS 5/5/2021 PERMIT/BID 02-05-2021 No. Issue Date 1#2 A Seal TEa M+TECT -0,R PERMIT/BID Store Number 20221 Approved Title Sheet TITLE SHEET T 1 M01 _j Municipal Approval Stamps SYMBOLS LEGEND ELEVATION TARGETS ELEVATION DESIGNATION 3 A3-01 A5-01 SHEET REFERENCE NUMBER EXTERIOR ELEVATION INTERIOR ELEVATION WALL SECTION TARGETS SECTION DESIGNATION 2 A6-01 SHEET REFERENCE NUMBER DETAIL SECTION TARGETS SECTION DESIGNATION - 3A A6-11 SHEET REFERENCE NUMBER AREA DETAIL REFERENCE DETAIL DESIGNATION 1 A5-10 SHEET REFERENCE NUMBER DETAIL TARGETS SCALE = NTS DETAIL DESIGNATION EXIT A 3 A6-03 SHEET REFERENCE NUMBER BUILDING SECTION TARGETS DETAIL DESIGNATION 2 A3-01 SHEET REFERENCE NUMBER I 2 A3-01 O� WINDOW NUMBER 03 (SEE WINDOW SCHEDULE) WINDOW DESIGNATION 01 KEY NOTE REVISION TAG ROOM FINISH TARGET FLOOR FIN DESIG. VCT-1 � WALL FINISH DESIG. PT-1 VB-1 WD-2 BASE DESIGNATION FLOOR TRANSITION WALL FINISH DESIGNATION MATCHING LINE MATCH LINE - SEE SHEET A2-12 SHEET REFERENCE NUMBER ELEVATION MARKS LA T/ SLAB VERTICAL HEIGHT EL +0'-0" (ELEVATION, SECTION) MISCELLANEOUS TARGETS ROOM NAME DOOR(ROOM)NUMBER ROOM ROOM DOOR SUFFIX - AS REQ'D 000 NUMBER 0 (SEE DOOR SCHEDULE) ROOM DESIGNATION DOOR DESIGNATION XXX E000 12 PARTITION TYPE EQUIPMENT DESIGNATION CUSTOM PRODUCT DESIGNATION SCALE = NTS SCALE = NTS SIGNARAMA 1414 S. 324TH S' FEDERAL WAY, SITE PLAN / VICINITY MAP ACCESS / EGRESS PLAN I i ABC o„ \ i LPN OCCUPANCY LOAD PLAN SHIPPING iE r-- i SHOWROOM STORAGE/STOCK/ SIGNAR MA DES GN AREA 1 PROJECT DESCRIPTION INTERIOR BUILD OUT OF A BUSINESS SPACE IN AN EXISTING BUILDING. TRADES TO INCLUDE CARPENTRY, ELECTRICAL AND PLUMBING. FEDERAL WAY BLDG CODES * * * * * * * * * AS AMENDED WITH ALL FEDERAL WAY REVISED CODE THE CITY CODE CONTAINS LOCAL AMENDMENTS TO THE STATE ADOPTED CODES, AS WELL AS ADDITIONAL ADMINISTRATIVE PROCEDURES. BUILDING 2018 INTERNATIONAL BUILDING CODE MECHANICAL 2018 INTERNATIONAL MECHANICAL CODE ELECTRICAL 2020 NATIONAL ELECTRIC CODE PLUMBING 2018 UNIFORM PLUMBING CODE (UPC) FIRE PREVENTION IFC 2018 EDITION, INCLUDING APPENDICES B, C, E, F, AND I ENERGY IECC 2018 EDITION & WSEC 2018 EDITION FUEL GAS IFGC 2018 EDITION LIFE SAFETY 2000 NFPA LIFE SAFETY CODE (IAC) ACCESSIBILITY ICC/ANSI A117.1-2009 2018 IBC CODE MATRIX SCOPE OF WORK: INTERIOR TENANT BUILD OUT IN AN EXISTING BUILDNG. EXIT ACCESS TRAVEL DISTANCE YEAR BUILT: NA ZONING CLASSIFICATION: CIF - CITY CENTER FRAME MAX. DISTANCE = 85'-6" CONSTRUCTION TYPE: IIB (TABLE 503) REFER TO A2-11 -DIMENSIONED FLOOR PLAN OCCUPANCY CLASSIFICATION: M - MERCHANTILE (SECTION 303) FOR EGRESS AISLE WIDTHS REFER TO E2.01 - LIGHTING PLAN FOR EMERGENCY LIGHTS & EXIT SIGN LOCATIONS. ALLOWABLE HEIGHT: EXISTING, NO CHANGE ACTUAL HEIGHT: EXISTING, NO CHANGE NUMBER OF STORIES: 1 RESUBMITTED May 12 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT ,I Sog►rarama ALLOWABLE AREA: EXISTING, NO CHANGE ACTUAL AREA: EXISTING, NO CHANGE TENANT SPACE GROSS AREA: 2,466 S.F. (EXISTING BUILDING) SEPARATION - USES: 1 HR - BUSINESS & MERCANTILE (TABLE 508.4) BUILDING ELEMENT FIRE RESISTANCE RATING REQUIREMENT (TABLE 601) REQUIRED PROVIDED STRUCTURAL FRAME: 0 HR EXISTING BEARING WALLS, EXTERIOR: 0 HR EXISTING BEARING WALLS, INTERIOR: 0 HR 0 HR NON -BEARING WALLS, EXT.: 0 HR EXISTING NON -BEARING WALLS, INT.: 0 HR 0 HR FLOOR CONSTRUCTION: 0 HR 0 HR ROOF CONSTRUCTION: 0 HR 0 HR LEGEND INTERIOR FINISHES: ALL INTERIOR FINISHES/MATERIALS SHALL COMPLY WITH CHAPTER 8 OF THE 2018 IBC PROJECT MUST FULLY COMPLY & MEET ALL ACCESSIBILITY ABC® ABC CLASS FIRE EXTINGUISHER NOTE: REQUIREMENTS OF THE AMERICAN DISABILITIES ACT, LOCAL COORDINATE ALL FIRE EXTINGUISHER LOCATIONS NOTES: CODE, ICC/ANSI 117.1A - 2009 & THE 2018 IBC (MOST WITH LOCAL FIRE DEPARTMENT. RESTRICTIVE REQUIREMENTS GOVERN). EGRESS CALCULATIONS OCCUPANCY LOAD (TABLE 1004.1.1) OCCUPANCY LOAD CALCULATIONS CALCULATIONS: DESCRIPTION AREA AREA PER OCCUPANT TOTAL TENANT ATI OCCUPANTS BUSINESS (1 PER 150 SF): NET AREA = 513 SF BUSINESS 1,768 SF (NET) 150 SF (NET) 12 513SF/150 =3.42 BUSINESS OCCUPANTS = 4 STORAGE / MECH. 698 SF (GROSS) 300 SF (GROSS) 2 STORAGE/STOCK/SHIPPING (1 PER 300 SF): GROSS AREA = 2,086 SF TOTAL OCCUPANT LOAD 14 - 2,086 SF / 300 = 6.9 EXIT ACCESS MAX. ALLOWED MAX. DISTANCE PROVIDED STORAGE OCCUPANTS = 7 TRAVEL DISTANCE: 100' 61'-4" TOTAL OCCUPANTS = 11 (TABLE 1016.2) CONTRACTOR TO PROVIDE A DURABLE OCCUPANT LOAD SIGN POSTED IN A PROMINENT LOCATION OF THE BUSINESS AREA, NEAR THE MAIN EXIT, AS REQUIRED PER INTERNATIONAL FIRE CODE (IFC), 2018 EDITION, INCLUDING APPENDICES B, C, E, F, AND I. VERIFY LOCATION WITH FIRE CODE INSPECTOR MINIMUM REQUIRED PROVIDED EGRESS DOOR WIDTH: 36" 36" EGRESS AISLE WIDTH: 44" 44" MINIMUM NUMBER OF EXITS: (TABLE 1021.1) REQUIRED PROVIDED 1 2 PLUMBING SYSTEMS�(2018 UPC) MINIMUM NUMBER OF (TABLE 422.1) PLUMBING FACILITIES: REQUIRED PROVIDED WATER CLOSETS: MALE: 1 PER 1 UNISEX TOILET ROOM 1 00 FEMALE: 1 PERR 1 URINALS: NONE NONE 1 MALE & 1 FEMALE LAVATORIES: 1 PER 40 (BOTH) 1 UNISEX TOILET ROOM DRINKING FOUNTAINS: 1 PER 100 BOTTLED WATER WILL BE PROVIDED SERVICE SINK: 1 1 1 Client THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. SIGNARAMA 1414 S. 324TH ST. STE B201 FEDERAL WAY, WA Project PCH IT ECTS 412 S. Wells Street , 2nd Floor � Chicago, IL 60607 P:3129550334 L d x u a r c h c o m Architect of Record Consultant 1 CITY COMMENTS 5/5/2021 PERMIT/BID 02-05-2021 No. Issue Date Seal 11204 STERED M+TECT kAp O'NER G L46SHINGTON PERMIT/BID Store Number 20221 Approved tle PROJECT INFO & CODE ANALYSIS I Sheet G 01 ABBREVIATIONS GENERAL REQUIREMENTS Municipal Approval Stamps AB anchor bolt ABV above ACOUS acoustical AD area drain ADH adhesive ADJ adjustable AFF above finish floor AGG aggregate AL aluminum ALUM aluminum ALT alternate ANDZ anodized ANN annunciator AP access panel APPROX approximate APT apartment ARCH architectural AUTO automatic AVE avenue AWG American wire gauge AT Acoustical Tile B/ bottom of BB baseboard BD board BITUM bituminous BLDG building BLKG blocking BM beam B.M. bench mark BR bedroom BRG bearing BSMT basement BTB back to back BUR built up roofing CEM cement CJ construction joint CL center line CLG ceiling CLO closet CM centimeter CMU concrete masonry unit CO cleanout COL column CONC concrete CONF conference CONSTR construction CONT continuous CONTR contractor COORD coordinate CORR corridor CRT cathode ray tube CTJ control joint CTR center CTSK countersunk CCTV closed circuit television CU cubic CW cold water CPT carpet DAR davit anchor DBL double DEG degree DEMO demolish DEPT department DET detail DIA diameter DIAG diagonal DIFF diffuser DIM dimension DISP dispenser DIV division DN down DO ditto DPFG damp -proofing DR door IDS downspout DW distilled water DWG drawing DWT dumbwaiter E East EA each EL elevation ELAS elastomeric ELECTR electrical ELEV elevator EMER emergency ENCL enclosure ED electric outlet EPNL electrical panel EXIST existing EXT exterior F/ face of FA fire alarm FBR face brick FC foot control FCO floor clean out FD floor drain FDN foundation FE fire extinguisher FEC fire extinguisher cabinet FFL finish floor FH fire hydrant FHMS flat head machine screw FHR fire hose rack FHWS flat head wood screw FIN finish FLR floor FLUOR fluorescent FRTW fire resistive treated wood FRPRF fireproof FT foot (feet) FTF face to face FTG footing FTR fin tube radiation FURN furnish FURR furring FUT future GA gauge R riser GALV galvanized R/W right-of-way GEN general RAD radius GL glass RB rubber GND ground RC reinforced concrete GNK gooseneck RD roof drain GPL gypsum plaster REC recessed GR grade REF reference GT grease trap REFR refrigerator GWB gypsum wallboard REINF reinforced GYP gypsum REQD required RESIL resilient HB hose bibb REV revision HC hollow core RFG roofing HDWD hardwood RM room HDWR hardware RMV remove HM hollow metal RO rough opening HO hold open HORIZ horizontal S South HP high point SAFB sound attenuation fire batt insulation HR hour SAV stain & varnish HT height SAN sanitary HTG heating SC solid core HW hot water SCHED schedule HYD hydrant SD soap dispenser SECT section IAW in accordance with SF square foot (feet) ID inside diameter SGT structural glazed tile IN inches SHR shower INCAN incandescent SHT sheet INCL include(d)(ing) SIM similar INSUL insulation SK sink INTR interior SMS sheet metal screw INV EL invert elevation SP standpipe SPEC specification JC Janitor's Closet SQ square JT joint SSK service sink SST stainless steel KID knockdown STA station KO knockout STC sound transmission class KIT kitchen STD standard KS knee space STER sterilizer STL steel STOR storage LAM laminate(s) STRUCT structural LAV lavatory SURG surgical LB(S) pound(s) SUSP suspended LG length SWBO switch board LL landlord LKR locker T tread LP low point T/ top of LT light T&B top & bottom LWT lightweight T&G tongue & groove TEL telephone TEMP tempered M meter TER terrazzo MAINT maintenance THK thick MAS masonry TL task light MATL material TOIL toilet MAX. maximum TOPO. topography MCB metal corner bead TV television M.E. match existing TYP typical MECH mechanical TRT-WD treated wood MEMB membrane MTL metal UNEX unexcavated MEZZ mezzanine UNF unfinished MFR manufacturer MH manhole UNO unless noted otherwise UON unless otherwise noted MIN minimum UR urinal MISC miscellaneous UTIL utility ML metal lath MLP metal lath & plaster VAC vacuum MM millimeter VTR vent thru roof MO masonry opening VERT vertical MOV movable VEST vestibule MS machine screw V.I.F. verify in field MTD mounted VOL volume MTG mounting VT vinyl tile MUL mullion W West N North W/ with NC nurse call W/O without N.I.C. not in contract WC water closet NO. number WD wood NOM nominal WF wide flange NTS not to scale WGL wire glass WH water heater OA overall WHC wheelchair OC on center WHT white OD outside diameter WI wrought iron OFF office WIN. window OH overhead WND window OPNG opening WM wire mesh OPP opposite WID work point WPFG waterproofing WSCT wainscot PA public address WT weight PC portland cement WWF welded wire fabric PHS phillips head screw PL plate YD yard P-LAM plastic laminate PLAS plaster PLBG plumbing PLUMB plumbing PLWD plywood PMF premolded filler PNL panel POL polished PR pair PREP prepare PROP. property PT paint PTN partition PTS pneumatic tube station QT quarry tile ARCHITECT'S INSTRUCTIONS SUBMITTALS: IF ALTERNATE EQUIPMENT IS PROPOSED DUE TO LEAD TIME, THE ARCHITECT OR ENGINEER MAY REQUEST PAYMENT FROM G.C. FOR REVIEW OF THE SUBMITTAL. GENERAL CONTRACTOR MUST VERIFY LONG LEAD ITEMS AT START OF PROJECT TO AVOID DELAYS & ALTERNATES. A f - III - _ THE GENERAL CONTRACTOR SHALL RED LINE ALL FIELD CHANGES ON A SET OF PRINTS TO REMAIN ON SITE THROUGHOUT THE CONSTRUCTION OF THE PROJECT. IT IS THE GC'S RESPONSIBILITY TO RECORD ALL FIELD CHANGES AND SUBMIT THE 'AS BUILTS' TO SIGNARAMA AT TURNOVER. SPECIAL INSPECTIONS (IF REQUIRED) 1. SPECIAL INSPECTIONS SHALL BE REQUIRED FOR THE FOLLOWING: CONCRETE, BOLT IN CONCRETE, REINFORCING STEEL, WELDING, SPECIAL GRADING, EXCAVATION & FILLING, & EIFS SYSTEMS. SPECIAL INSPECTIONS OF SPECIFIC ITEMS ARE TO BE PROVIDED ONLY IF REQUIRED BY LOCAL CODE OR CITY INSPECTORS. SPECIAL INSPECTIONS ARE IN ADDITION TO ALL STANDARD BUILDING INSPECTIONS REQUIRED & ARE NOT A SUBSTITUTE FOR INSPECTION BY A CITY INSPECTOR. ALL WORK REQUIRING SPECIAL INSPECTION WHICH IS INSTALLED OR COVERED WITHOUT THE APPROVAL OF THE CITY INSPECTOR IS SUBJECT TO REMOVAL AT THE CONTRACTORS EXPENSE. 2. CONTINUOUS INSPECTION IS REQUIRED DURING THE PERFORMANCE OF THE WORK UNLESS OTHERWISE SPECIFIED ON THE APPROVED PLANS. 3. SPECIAL INSPECTORS MUST BE CERTIFIED BY THE LOCAL MUNICIPALITY TO PERFORM THE TYPES OF INSPECTIONS REQUIRED. 4. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INFORM THE SPECIAL INSPECTOR OR INSPECTION AGENCY AT LEAST ONE WORKING DAY PRIOR TO PERFORMING ANY WORK THAT REQUIRES SPECIAL INSPECTION. 5. LICENSED FABRICATOR REQUIRED FOR STEEL SHAPES. 6. WELDING TO BE DONE BY WELDERS CERTIFIED BY THE LOCAL MUNICIPALITY (STRUCTURAL STEEL, REINFORCING STEEL & LIGHT GAUGE STEEL.) G.C. COMPLIANCE OWNER'S GENERAL CONTRACTOR SHALL VISIT THE PREMISES AND VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION AND SHALL REPORT ALL DISCREPANCIES TO TENANT'S ARCHITECT. TENANT'S GENERAL CONTRACTOR SHALL CONFORM TO ALL REQUIREMENTS REGARDING CONSTRUCTION PROCEDURES, INSURANCE, ETC., AS SET FORTH BY THE LANDLORD. GC TO VERIFY THE EXACT LOCATION OF ALL EXISTING LANDLORD FEATURES I.E. METAL BRACE FRAME, STOREFRONT OPENINGS, CORRIDOR ACCESS DOOR, DEMISING WALLS, UTILITY P.O.C., ETC. FIRE SPRINKLERS 1. COMPLETE PLANS AND SPECIFICATIONS FOR FIRE -EXTINGUISHING SYSTEMS, INCLUDING AUTOMATIC SPRINKLERS AND WET AND DRY STANDPIPES; HALON SYSTEMS AND OTHER SPECIAL TYPES OF AUTOMATIC FIRE -EXTINGUISHING SYSTEMS; BASEMENT PIPE INLETS; AND OTHER FIRE PROTECTION SYSTEMS AND APPURTENANCES THERETO SHALL BE SUBMITTED TO FIRE AND LIFE SAFETY FOR REVIEW AND APPROVAL PRIOR 2. FIRE EXTINGUISHING SYSTEM SHALL BE IN ACCORDANCE WITH IFC 2018 EDITION INCLUDING APPENDICES B, C, E, F AND I. 3. EXI G S KLE STE RE AND EXP ED I ADD PROVIDE GRID AND UPTURNED SPRINKLER HEADS PER CODE AND TENANT LANDLORD WORKLETTERS. 4. SPRINKLER CONTRACTOR TO ADJUST AND/OR ADD HEADS AS REQ'D FOR NEW LAYOUT. 5. S.C. TO PROVIDE DRAWINGS AND CALCS FOR CITY APPROVAL. 1. THE GENERAL CONTRACTOR SHALL INCLUDE IN HIS BID THE COST FOR A COMPLETE OPERATIONAL FIRE ALARM SYSTEM AS NEEDED TO MEET THE MINIMUM REQUIREMENTS OF THE CODE AND INCLUDES SYSTEM WITHIN BID. THIS SYSTEM MAY INCLUDE, BUT NOT BE LIMITED TO, HORN/STROBE, STROBES, PULL STATIONS, AREA SMOKE DETECTORS, DUCT SMOKE DETECTORS, AND REMOTE TEST STATIONS. A LICENSED FIRE ALARM CONTRACTOR SHALL PREPARE AND SUBMIT A COMPLETE FIRE ALARM SYSTEM DRAWING AND MATERIALS LIST, PRIOR TO COMMENCING ANY WORK. 2. THE GENERAL CONTRACTOR SHALL REVIEW ALL THE TENANT LANDLORD WORKLETTERS AND PROVIDE THE REQUIRED LANDLORD WORK FOR EACH WORKLETTER. SIGNAGE OWNER'S SIGNAGE CONTRACTOR SHALL PREPARE SIGNAGE SHOP DRAWINGS AND SUBMIT TO BUILDING DEPT. & LANDLORD FOR APPROVAL. ALL SIGNAGE IS UNDER SEPARATE PERMIT. BID NOTES 1. BID FORMS TO BE PROVIDED BY CLIENT TO G.C. 2. ALL ITEMS NOTED AS (N.I.C.) TO BE BID SEPARATELY FROM THE BASE BID. 3. G.C. RESPONSIBLE FOR COORD. W/ ALL UTILITY CO. INCLUDING BUT NOT LIMITED TO: ELECTRICAL, WATER, WASTE, STORM, PHONE/DATA TO PROVIDE SERVICES AS CALLED FOR ON THE DRAWING. LOAD LETTERS & SERVICE APPLICATIONS TO BE COMPLETED & SUBMITTED BY G.C. 4. IF SPRINKLER SYSTEM IS REQ'D, G.C. TO PROVIDE SPRINKLER SYSTEM DESIGN & PERMIT. SEE FIRE DEPT. NOTES 5. IF FIRE ALARM SYSTEM IS REQ'D, G.C. TO PROVIDE FIRE SYSTEM DESIGN & PERMIT. SEE FIRE DEPT. NOTES RESUBMITTED May 12 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT ldgr! ram a Client THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. SIGNARAMA 1414 S. 324TH ST. STE B201 FEDERAL WAY, WA Project D ARCHITECTS 412 S. Wells Street - 2nd Floor - Chicago - IL - 60607 F:3129550334 - dxuarch.com Architect of Record Consultant 1 CITY COMMENTS 5/5/2021 PERMIT/BID 02-05-2021 No. Issue Date 11204 Seal TERE D MIITEC T 9rVER YASHINGTON PERMIT/BID Store Number 20221 Approved Title GENERAL NOTES & ABBREVIATIONS Sheet G 1-02 GENERAL NOTES Municipal Approval Stamps GENERAL NOTES 1. CONTRACTOR SHALL FIELD VERIFY TYPE OF SOILS. IF CORROSIVE SOILS ARE ENCOUNTERED, TAKE NECESSARY PRECAUTIONS FOR ALL UNDER GROUND WORK. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS ON DRAWINGS FOR CONFLICTS PRIOR TO CONSTRUCTION. THE CONTRACTOR WILL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. DO NOT SCALE DRAWINGS. 3. BIDDERS ARE INSTRUCTED TO CAREFULLY REVIEW THE CONSTRUCTION DOCUMENTS & SITE. 4. NO STRUCTURE OF ANY KIND TO BE CONSTRUCTED ON, OVER OR PLACED WITHIN THE PUBLIC UTILITY EASEMENTS EXCEPT WOOD, WIRE OR REMOVABLE SECTION TYPE FENCING AND/OR PAVING. 5. CONTRACTOR TO COORDINATE STAGING AREAS AS REQUIRED WITH LANDLORD & OWNER. 6. ANY DAMAGE BY G.C. OR SUBCONTRACTOR TO EXISTING ASPHALT PAVEMENT AND/OR EXISTING LANDSCAPING OUTSIDE OF CONSTRUCTION LIMIT LINE SHALL BE REPAIRED AT NO COST TO OWNER. 7. SIDEWALK ELEVATIONS TO BE COORDINATED WITH SITE AS -BUILT CONDITIONS. ARCHITECT TO BE NOTIFIED OF ANY DISCREPANCIES. 8. G.C. TO COORDINATE LOCATION & PLACEMENT OF GREASE REMOVAL SYSTEM WITH PLUMBING CONTRACTOR. FIELD VERIFY ANY (E) SITE CONDITIONS THAT MAY IMPEDE INSTALLATION AND/OR OPERATION OF SUCH. 9. APPROVED NUMBERS OR ADDRESSES SHALL BE MAINTAINED & AS CURRENTLY PLACED ON BUILDING. 10. NO MATERIALS SHALL BE STORED ON PUBLIC PROPERTY UNLESS AN ENCROACHMENT PERMIT IS FIRST OBTAINED FROM THE PUBLIC WORKS DEPARTMENT. 11. ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD AT FRAMED WALLS & SOFFITS, TYPICAL UNLESS OTHERWISE NOTED. AT MILLWORK LOW WALLS, DIMENSIONS ARE TO FACE OF FINISHED WALL, TYPICAL. 12. CONTRACTOR SHALL PROVIDE CONSTRUCTION FENCE FOR PEDESTRIAN PROTECTION ACCORDING TO LOCAL REGULATIONS & BUILDING CODE. 13. TEMPORARY TOILET FACILITIES SHALL BE PROVIDED. 14. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETE SECURITY & SAFETY OF THE SITE WHILE THE JOB IS IN PROGRESS & UNTIL THE JOB IS COMPLETE. 15. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS & WORKERS AT ALL TIMES 16. ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES DAILY & WORK AREAS SHALL BE LEFT IN A CLEAN (BROOM) CONDITION AT ALL TIMES. 17. CONTRACTOR SHALL PROVIDE A LIST OF SUBCONTRACTORS TO THE OWNER. 18. CONTRACTOR SHALL COMPLY WITH ALL STATE & LOCAL RULES & REGULATIONS CONCERNING LICENSING WHICH THE APPLICABLE GOVERNING AUTHORITY MAY HAVE ADOPTED. 19. ALL WEATHER -EXPOSED SURFACES SHALL HAVE A WEATHER -RESISTIVE BARRIER TO PROTECT THE INTERIOR WALL COVERING. EXTERIOR OPENINGS SHALL BE FLASHED IN SUCH A MANNER AS TO MAKE THEM WATERPROOF. 20. GENERAL CONTRACTOR SHALL PLACE ORDERS FOR ALL FINISHES, ALL MATERIALS, EQUIPMENT; ETC. AT THE START OF THE PROJECT. SUBSTITUTIONS ARE NOT ACCEPTED FOR ANY ITEMS, UNLESS NOTED OTHERWISE. OWNER & ARCHITECT MUST BE INFORMED OF LEAD TIME PROBLEMS WITHIN THE FIRST TWO WEEKS OF THE PROJECT. 21. NOT USED 22. SIGNS ARE REQUIRED FOR ALL MP&E ROOMS & SPRINKLER CONTROL VALVE ROOMS. 23. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, THE APPLICANT SHALL HAVE EVIDENCE OF CURRENT WORKMAN'S COMPENSATION INSURANCE COVERAGE ON FILE WITH THE DEPARTMENT IN COMPLIANCE WITH THE LOCAL LABOR CODE. 24. AFTER OBTAINING BUILDING PERMIT AND BEFORE COMMENCING WITH THE WORK, THE GENERAL CONTRACTOR SHALL SHOW EVIDENCE OF ALL THE INSURANCE REQUIREMENTS. 25. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND OBTAIN ALL PERMITS AND LICENSES AND PAY REQUIRED FEES. 26. CONTRACTOR SHALL BE FAMILIAR WITH ALL LANDLORD REQUIREMENTS AND SHALL BE RESPONSIBLE FOR COMPLIANCE WITH SAME. CONTRACTOR SHALL INVESTIGATE LOCAL CODES AND PROCEDURES AND SHALL COMPLY WITH ALL REQUIREMENTS. 27. A COPY OF LANDLORD'S FINAL APPROVED PLANS MUST BE ON SITE DURING CONSTRUCTION. 28. REMOVE ALL ABANDONED IMPROVEMENTS, INCLUDING ELECTRICAL AND MECHANICAL, IF ANY. 29. INSPECT SITE: VERIFY FIELD DIMENSIONS BEFORE COMMENCING CONSTRUCTION. NOTIFY TENANT AND LANDLORD IMMEDIATELY IF THERE ARE ANY SIGNIFICANT DISCREPANCIES. 30. WHERE FACTORY FINISHED OR FACTORY PRIMED ITEMS OCCUR, SUCH AS GRILLES, DIFFUSERS, METAL TRIM AND ACCESSORIES, ETC. THEY SHALL BE PAINTED TO MATCH THE ADJACENT SURFACE AND AS DIRECTED BY THE OWNER. 31. CONTRACTOR SHALL, IN THE WORK OF ALL TRADES, PERFORM ANY AND ALL CUTTING, PATCHING, REPAIRING, RESTORING AND THE LIKE NECESSARY TO COMPLETE THE WORK AND TO RESTORE ANY DAMAGED OR AFFECTED SURFACES RESULTING FROM THE WORK OF THIS CONTRACT TO THEIR ORIGINAL CONDITION TO THE SATISFACTION OF THE OWNER. 32. THERE SHALL BE NO EXPOSED PIPE, CONDUITS, ETC. IN PUBLIC AREAS, LINO. ALL SUCH LINES SHALL BE CONCEALED OR FURRED AND FINISHED. 33. GENERAL CONTRACTOR SHALL COORDINATE WORK PERFORMED BY OTHER CONTRACTORS. DISCREPANCIES IF ANY, SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK. 34. SHOULD THE DRAWINGS DISAGREE WITH THEMSELVES OR WITH THE SPECIFICATIONS OR SHOULD THE SPECIFICATIONS DISAGREE WITH THEMSELVES, THE BETTER QUALITY AND/OR GREATER QUANTITY OF WORK OR MATERIAL SHALL BE ESTIMATED UPON AND UNLESS OTHERWISE ORDERED IN WRITING SHALL BE FURNISHED AND INSTALLED. 35. NO SUBSTITUTIONS ARE PERMITTED UNLESS PRIOR APPROVAL BY THE OWNER. 36. IF ANY DISCREPANCIES APPEAR IN CONTRACT DOCUMENTS, CONTRACTOR SHALL NOTIFY ARCHITECT IN WRITING OF SUCH DISCREPANCIES PRIOR TO BID. 37. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE TIMELY ARRIVAL OF ALL SPECIFIED FINISH MATERIALS EQUIPMENT, LIGHT FIXTURES AND ANY OTHER SUCH MATERIAL (S) TO BE UTILIZED ON THE PROJECT. THE GENERAL CONTRACTOR SHALL NOTIFY THE OWNER IN WRITING WITHIN 10 DAYS OF THE DATE OF CONTRACT OF THOSE SPECIFIED ITEMS THAT MAY NOT BE READILY AVAILABLE. IF NOTIFICATION IS NOT RECEIVED BY THE OWNER THE CONTRACTOR ACCEPTS RESPONSIBILITY FOR THE PROPER ORDERING AND FOLLOW-UP OF SPECIFIED ITEMS AND WILL PURSUE WHATEVER MEANS NECESSARY AT NO ADDITIONAL COST TO THE OWNER, INSURE AVAILABILITY OF ALL SPECIFIED ITEMS SO AS NOT TO CREATE A HARDSHIP ON THE OWNER AND NOT DELAY PROGRESS OF THE WORK. NO EXTENSION OF TIME TO THE CONTRACT WILL BE ALLOWED. 38. MECHANICAL CONTRACTORS SHALL VERIFY EXACT DIMENSIONS WITH EQUIPMENT MANUFACTURERS. MECHANICAL CONTRACTOR SHALL VERIFY ALL SIZES AND LOCATIONS OF DUCT OPENINGS BEFORE INSTALLATION AND VERIFY DISCREPANCIES, IF ANY. 39. ALL EXTERIOR WALL OPENINGS, FLASHING, COUNTER FLASHING, COPING AND EXPANSION JOINTS SHALL BE WEATHERPROOF. 40. CAULKING AND SEALANTS: ALL OPEN JOINTS PENETRATIONS AND OTHER OPENINGS IN THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED, GASKETED, OR WEATHER STRIPPED TO LIMIT AIR AND WATER LEAKAGE. 41. USE ACOUSTICAL SEALANT AROUND ALL PIPES, DUCTS CONDUITS, OUTLETS, SWITCHES, ETC. ON BOTH SIDES OF CROSSING/PENETRATING WALLS WITH THERMAL AND ACOUSTIC INSULATION. 42. ALL NOISE BARRIER BATTS (SOUND INSULATION) SHALL BE NON-COMBUSTIBLE. 43. EACH CONTRACTOR SHALL LEAVE THE SITE IN A NEAT, CLEAN AND ORDERLY CONDITION ON A DAILY BASIS AND UPON CONCLUSION OF HIS WORK. ALL WASTE, RUBBISH AND EXCESS MATERIALS SHALL BE REMOVED FROM THE SITE PROMPTLY. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ALL TRASH GENERATED BY OWNERS CONTRACTORS FOR THE DURATION OF THE PROJECT. 44. SAFETY: ALL CONDUIT, WORK EQUIPMENT AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE LATEST SAFETY RULES AND REGULATIONS OF ALL AUTHORITIES AND AGENCIES HAVING JURISDICTION OVER THE WORK. 45. CONSULT PROPERTY UTILITY PLANS BEFORE SAW CUTTING CONCRETE SLAB, IF ANY. 46. THE ARCHITECT WILL NEITHER HAVE CONTROL OVER OR CHARGE OF, NOR BE RESPONSIBLE FOR, THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR THE SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, SINCE THESE ARE SOLELY THE CONTRACTOR'S RIGHTS AND RESPONSIBILITIES. FIRE DEPARTMENT NOTES 1. CONTRACTOR TO PROVIDE A SUFFICIENT NUMBER OF 2A10BC RATED FIRE EXTINGUISHERS DURING CONSTRUCTION SO THAT ALL PORTIONS OF THE BUILDING ARE WITHIN 75 FT. TRAVEL DISTANCE OF SAID EXTINGUISHER & SO THAT AT LEAST ONE 2A10BC RATED FIRE EXTINGUISHER IS PROVIDED FOR EACH 3,000 SQ. FT. OF FLOOR SPACE OR PORTION THEREOF. 2. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 40-B FOR KITCHEN. LOCATE EXTINGUISHERS PER LOCAL FIRE DEPARTMENT INSPECTOR. 3. PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR DURING CONSTRUCTION & FOR COMPLETED PROJECT. 4. ALL EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL. 5. ALL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT SPECIAL KNOWLEDGE OR EFFORT (NO DEAD BOLTS, NO SLIDING BOLTS, ETC.). 6. AN OCCUPANT LOAD SIGN SHALL BE POSTED IN EACH ASSEMBLY ROOM HAVING AN OCCUPANT CONTENT OF 50 OR MORE. SIGN IS TO BE POSTED NEAR ENTRANCE, COORDINATE LOCATION OF SUCH SIGN WITH FIRE MARSHAL. SIGN TO BE PROVIDED & INSTALLED BY OWNER VENDOR. 7. MAINTAIN MIN. 44" AISLES TO EXIT OR PUBLIC WAY. 8. PROVIDE EXIT SIGNS ABOVE EXITS WITH MIN. 3/4"x6" LETTERS LIGHTED ON CONTRASTING BACKGROUND. 9. EXIT SIGNS MUST BE INTERNALLY ILLUMINATED. 10. PROVIDE TWO (2) SEPARATE POWER SUPPLIES FOR EXIT SIGNS CONFORMING TO CODE SECTION. 11. PROVIDE EMERGENCY EXIT LIGHTING PROVIDING A VALUE OF ONE FOOT CANDLE AT FLOOR LEVEL. 12. ADDITIONAL EXIT SIGNS WILL BE PROVIDED AS/IF DIRECTED BY THE CITY INSPECTOR. 13. SEE "ROOM FINISH SCHEDULE" FOR SMOKE DENSITY RATING & FLAME SPREAD RATING OF MATERIALS USED. 14. INTERIOR WALL & CEILING FINISHES FOR ASSEMBLY AREAS SHALL NOT EXCEED AN END POINT FLAME SPREAD RATING OF 20. 15. ANY DECORATIONS USED SHALL BE NON-COMBUSTIBLE OR FLAME PROOFED IN AN APPROVED MANNER. 16. DRAPES & OTHER DECORATIVE MATERIALS SHALL BE FLAME RETARDANT. CERTIFICATION THEREOF SHALL BE PROVIDED. EXITS, EXIT SIGNS, FIRE ALARM STATIONS, HOSE CABINETS & EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED BY DECORATIVE MATERIALS. 17. FINISHES SHALL NOT EXCEED CLASS A, B OR C AS INDICATED IN THE BUILDING CODE. 18. PROVIDE OUTSIDE GAS SHUT - OFF VALVE CONSPICUOUSLY MARKED. 19. UNLESS ALREADY EXISTING, AN APPROVED SET OF NUMERALS, MINIMUM 4" HIGH WITH A STROKE WIDTH OF NOT LESS THAN 1/2 INCH, SHALL BE PLACED ON THE BUILDING. THE NUMBERING SHALL BE PLACED IN SUCH A POSITION AS TO BE PLAINLY VISIBLE & LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. SAID NUMERALS SHALL CONTRAST W/ THEIR BACKGROUND. IF THE ADDRESS THAT IS POSTED NEAR THE INTERSECTION OF THE DRIVEWAY & THE PUBLIC STREET OR ROAD FRONTING THE PROPERTY IS NOT VISIBLE, ADDITIONAL ADDRESSES POSTED NEAR THE INTERSECTION OF THE DRIVEWAY & THE PUBLIC STREET ARE REQUIRED. (VERIFY REQUIREMENTS.) 20. PROVIDE A KNOX BOX FOR FIRE DEPT. ACCESS & KEY ACCESS, LOCATION AS DETERMINED BY FIRE MARSHAL. 21. EXIT SIGNAGE SHALL BE PROVIDED & MAINTAINED FOR CORRIDORS & AISLE WAYS LEADING TO EXITS IN ACCORDANCE WITH STATE CODE. SIGNAGE SHALL STATE: "OBSTRUCTIONS, INCLUDING STORAGE, SHALL NOT BE PLACED IN THE REQUIRED WIDTH OF AN EXIT OR EXIT PASSAGEWAY." 22. GENERAL CONTRACTOR SHALL SECURE PERMITS REQUIRED BY THE FIRE DEPARTMENT FROM THE FIRE DEPARTMENT PRIOR TO OCCUPYING THIS BUILDING. 23. FIRE DEPARTMENT FINAL INSPECTION REQUIRED. G.C. TO VERIFY INSPECTION SCHEDULING REQUIREMENTS AT LEAST 14 DAYS PRIOR TO COMPLETION OF WORK. 24. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE & COMBUSTIBLE LIQUIDS, FLAMMABLE & COMPRESSED GASES & OTHER HAZARDOUS MATERIALS SHALL COMPLY WITH STATE BUILDING CODE REGULATIONS. 25. NOT USED. 26. WHEN ALLOWED BY FIRE MARSHAL AND/OR BUILDING INSPECTOR, FIRE BLOCKS CAN BE SUBSTITUTED WITH APPROVED FIRE SPRINKLER SYSTEM. 27. IN ADDITION TO THE SPRINKLER MONITORING SYSTEM, A FIRE SYSTEM PER NFPA #13 SPECIFICATIONS MUST BE INSTALLED. PLANS FOR THE FIRE ALARM MUST BE SUBMITTED TO THE BUILDING DEPARTMENT FOR FIRE DEPARTMENT REVIEW PRIOR TO INSTALLATION. THE KITCHEN HOOD FIRE PROTECTION SYSTEM WILL CAUSE INITIATION OF AN ALARM SIGNAL. 28. ALL EXIT DOORS & INTERVENING DOORS ON THE EXIT PATH, IF PROVIDED WITH A LOCK OR LATCH, MUST BE PROVIDED WITH PANIC HARDWARE. 29. NOT USED. 30. THE FIRE SPRINKLER SYSTEM DESIGN CRITERIA IS AS SET FORTH BY THE FIRE MARSHAL. 31. PREMISES IDENTIFICATION TO BE LEGIBLE FROM STREET OR DRIVE & MUST BE ON ALL PLANS. 32. IT IS THE DEVELOPERS RESPONSIBILITY TO DETERMINE ULTIMATE COMPLIANCE WITH THE FAIR HOUSING AMENDMENTS ACT & AMERICANS WITH DISABILITIES ACT & INCORPORATE SAME INTO THEIR BUILDING PLANS (PER C.O.S. 91-3) 33. BACK FLOW PREVENTION WILL BE REQUIRED ON VERTICAL RISER ON CLASS I & II FIRE SPRINKLER SYSTEM PER THE LOCAL MUNICIPALITY CODE. 34. EXIT & EMERGENCY LIGHTING SHALL COMPLY WITH THE CITY ORDINANCE & 2018 IFC. 35. SPRINKLER SYSTEM SHALL BE INSTALLED TO COMPLY WITH MINIMUM NFPA CRITERIA & CITY ORDINANCE. SYSTEMS WITH 20 HEADS OR MORE SHALL HAVE OFF -SITE MONITORING. AFTER BUILDING PLAN REVIEW, INSTALLING CONTRACTOR SHALL SUBMIT (3) COMPLETE SETS OF DRAWINGS & HYDRAULIC CALCULATIONS. 36. REVIEWED BY MINIMUM NICET III DESIGN TECHNICIAN. NFPA COMMERCIAL SYSTEM / DESIGN CRITERIA: ORD. GR. II - 0.20/1500 (1996 EDITION) - PE STAMP REQUIRED 37. CONSTRUCTION WITHIN THE LOCAL MUNICIPALITY SHALL COMPLY WITH THE STATE FIRE CODE STANDARDS, AS AMENDED BY THE COUNTY CONSTRUCTION ORDINANCE, SUBTITLE 11. 38. THE APPLICANT IS RESPONSIBLE TO IDENTIFY & COORDINATE DEFERRED SUBMITTALS. 39. PLANS & SPECIFICATIONS FOR FIRE SPRINKLER SYSTEMS EXCEEDING 19 HEADS SUBMITTED FOR REVIEW SHALL BE SEALED BY A QUALIFIED STATE REGISTRANT IN FIRE SPRINKLER DESIGN. THE INSTALLING CONTRACTOR'S NAME, ADDRESS & PHONE NUMBER ARE TO BE INCLUDED ON THE DRAWINGS & CALCULATIONS SUBMITTED FOR REVIEW & APPROVAL. AS -BUILT DRAWINGS WILL BE REQUIRED WHERE FIELD CHANGES ARE MADE TO THE DESIGNED DRAWINGS. 40. FIRE SPRINKLERS SHALL BE INSTALLED IN ALL CONCEALED SPACES ENCLOSED WHOLLY OR PARTLY BY EXPOSED COMBUSTIBLE CONSTRUCTION. 41. PLANS & SPECIFICATIONS FOR FIRE ALARM SYSTEMS, AUTOMATIC FIRE -EXTINGUISHING SYSTEMS, STANDPIPES & THEIR APPURTENANCES SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT FOR REVIEW & APPROVAL PRIOR TO INSTALLATION. GENERAL FIRE ALARM SYSTEM NOTES 1. PLANS AND SPECIFICATIONS FOR FIRE ALARM SYSTEMS SUBMITTED FOR REVIEW SHALL BE SEALED BY A QUALIFIED STATE REGISTRANT IN FIRE ALARM SYSTEM DESIGN. 2. ALARM INITIATING DEVICES, ALARM SIGNALING DEVICES, AND OTHER FIRE ALARM SYSTEM COMPONENTS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH IFC SECTION 907. 3. WHEN DUCT DETECTORS, REQUIRED BY IMC 606 OR IFC AND IBC SECTION 909, ARE CONCEALED FROM VIEW OR INSTALLED MORE THAN 10 FEET ABOVE FINISHED FLOOR OR IN ARRANGEMENTS WHERE THE DETECTOR'S ALARM INDICATOR IS NOT READILY VISIBLE TO RESPONDING PERSONNEL, AN LED SHALL BE PROVIDED THROUGH THE CEILING LEVEL OR SIGHT OBSTRUCTION AT EACH DETECTOR. ALL DETECTION DEVICES PROVIDED SHALL BE MONITORED FOR INTEGRITY BY THE FIRE ALARM SYSTEM WHERE A FIRE ALARM IS INSTALLED. ACCESSIBILITY NOTES 1. ACCESS TO THESE FACILITIES SHALL BE PROVIDED AT PRIMARY ENTRANCES, AS REQUIRED BY ADA. 2. SURFACES WITH A SLOPE OF 6% GRADIENT OR GREATER SHALL BE SLIP RESISTANT. 3. SURFACE CROSS SLOPES SHALL NOT EXCEED 1/4" PER FOOT. 4. WHEN THE SLOPE IN THE DIRECTION OF TRAVEL OF ANY WALK EXCEEDS 1 VERTICAL TO 20 HORIZONTAL, IT SHALL COMPLY WITH THE PROVISIONS OF A PEDESTRIAN RAMP. 5. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2". WHEN CHANGES IN LEVEL DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2, EXCEPT THAT LEVEL CHANGES NOT EXCEEDING 1/4" MAY BE VERTICAL. WHEN CHANGES IN LEVELS GREATER THAN 1/2" ARE NECESSARY, THEY SHALL COMPLY WITH THE REQUIREMENTS FOR CURB RAMPS. 6. EVERY REQUIRED EXIT DOORWAY SHALL BE SIZED FOR A DOOR NOT LESS THAN 3 FT. WIDE BY NOT LESS THAN 6'-8" HIGH CAPABLE OF OPENING 90° & MOUNTED SO THAT THE CLEAR WIDTH OF THE EXIT WAY IS 32" MIN. 7. THRESHOLDS TO BE A MAX. 1/2" ABOVE ADJACENT FINISH FLOOR. 8. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS FOR ALL DOORS, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO THE MAXIMUM ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 LBS. 9. THE BOTTOM 10" OF ALL DOORS EXCEPT AUTOMATIC & SLIDING SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE. 10. PROVIDE LEVER -TYPE HARDWARE PANIC BARS, PUSH - PULL ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. (30" TO 44" A.F.F.) 11. ALL DOORWAYS LEADING TO SANITARY FACILITIES SHALL HAVE 32" CLEAR UNOBSTRUCTED OPENING & A LEVEL & CLEAR AREA FOR A MINIMUM DEPTH OF 60" IN THE DIRECTION OF THE DOOR SWING. 12. WHERE APPLICABLE, LOCATE EMPLOYEE LOCKERS AS NOTED ON PLANS. 13. 1/4" THICK IDENTIFICATION SYMBOLS (A 12" TRIANGLE FOR MEN, A 12" DIAMETER CIRCLE FOR WOMEN OR A TRIANGLE SUPERIMPOSED ON A 12" DIAMETER CIRCLE FOR UNISEX) CENTERED AT HEIGHT OF 60" A.F.F, SHALL BE PROVIDED ON DOORS TO SANITARY FACILITIES. 14. THERE SHALL BE A LEVEL & CLEAR FLOOR OR LANDING ON EACH SIDE OF A DOOR. THE LEVEL ARE SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60" & THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 48" AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN THE CLOSED POSITION. SUBMIT FOR ARCHITECTS REVIEW. 15. WALKS, HALLS, CORRIDORS, PASSAGEWAYS, AISLES OR OTHER CIRCULATION SPACES SHALL HAVE 80" MINIMUM CLEAR HEADROOM. 16. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE. HAND -ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 30" & 44" ABOVE THE FLOOR. LATCHING & LOCKING DOORS THAT ARE HAND -ACTIVATED & WHICH ARE IN A PATH OF TRAVEL, SHALL BE OPENABLE WITH A SINGLE EFFORT BY LEVER- TYPE HARDWARE, BY PANIC BARS, PUSH/PULL ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. LOCKED EXIT DOORS SHALL OPERATE AS ABOVE IN EGRESS DIRECTION. 17. GROUND & FLOOR SURFACES ALONG ACCESSIBLE ROUTES & IN ACCESSIBLE ROOMS & SPACES, INCLUDING FLOORS, WALKS, RAMPS, STAIRS & CURB RAMPS, SHALL BE STABLE, FIRM, & SLIP -RESISTANT. 18. OBJECTS PROJECTING FROM WALLS WITH THEIR LEADING EDGES BETWEEN 27" & 80" ABOVE THE FINISH FLOOR SHALL PROTRUDE NO MORE THAN 4" INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS OR AISLES. OBJECTS MOUNTED AT OR BELOW 27" ABOVE FINISH FLOOR MAY PROTRUDE ANY AMOUNT. 19. IF CARPET OR CARPET TILE IS USED ON A GROUND OR FLOOR SURFACE IN A COMMON USE AREA, IT SHALL HAVE FIRM BACKING OR NO BACKING. THE MAXIMUM PILE HEIGHT SHALL BE 1/2". EXPOSED EDGES OF CARPET SHALL BE FASTENED TO FLOOR SURFACES & HAVE TRIM ALONG THE EXPOSED EDGE & TRIM SHALL COMPLY WITH THE REQUIREMENTS FOR CHANGES IN LEVEL. RESUBMITTED May 12 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT A:rsigp rams Client THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. SIGNARAMA 1414 S. 324TH ST. STE B201 FEDERAL WAY, WA Project D U ARCHITECTS 412 S. Wells Street - 2nd Floor - Chicago - IL - 60607 F:3129550334 - dxuarch.com Architect of Record Consultant 1 CITY COMMENTS 5/5/2021 PERMIT/BID 02-05-2021 No. Issue Date 11204 Seal TERE l HIITEC T 9rVER YASHINGTON PERMIT/BID Store Number 20221 Approved Title GENERAL Sheet NOTES Gi M03 Municipal Approval Stamps FRONT APPROACH FRONT APPROACH ANY PUSH SIDE PUSH SIDE DOOR PROVIDED WITH BOTH CLOSER AND LATCH RESUBMITTED 4" MAX. CLEAR AMOUNT — CANE HITS POST OR PYLON BEFORE PERSON HITS OBJECT LOBBY WIDTH z LIN May 12 2021 12 MIN. CITY OF FEDERAL WAY O— — COMMUNITY DEVELOPMENT z C10 FRONT APPROACH PULL SIDE z Q qparama 2 7 CV N N HINGE APPROACH —1 PUSH SIDE Client THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. 2" MAX CANE RANGE Z _ � z o 2 z 1 SIGNARAMA 36"MIN. 42"MIN. 1414 S. 324TH ST. STE B201 22" MIN. PROTRUDING OBJECTS FEDERAL WAY, WA 4 N.T.S. Project HINGE APPROACH HINGE APPROACH Lo PULL SIDE PULL SIDE NOTES: PROTRUDING OBJECT 1. 1/2" MAXIMUM TOTAL HEIGHT WITH 1/4" MAXIMUM VERTICAL FREESTANDING OBJECT CHANGE AT EDGE. MOUNTED ON POSTS OR 2. 1 :2 SLOPED BEVEL REQUIRED IF LEVEL CHANGE IS OVER HINGE APPROACH DX PYLON MAY OVERHANG 1/4" VERITCAL LEVEL CHANGE. PUSH SIDE DOOR WITH CLOSER AND LATCH 12" MAX FROM 27" TO 80" 3. 1/4" MAXIMUM VERTICAL LEVEL CHANGE. A ABOVE FINISH FLOOR 1'-p° 10 COMPRESSED CARPET 1/4" MAX. FIN. FLOOR LEVEL 1FDCH�TECTS 4 BELOW THRESHOLD 412 S. Wells Street 2nd Floor ° Chicago ° OBJECT PROJECTION � � o ° IL 60607 g FROM WALL BETWEEN 27" X THRESHOLD 1 z LMIN z P: 3 1 2 9 5 5 0 3 3 4 ° d x u a r c h c o m TO 80" ABOVE FINISH = Architect of Record FLOOR SHALL PROTRUDEUj � Lo 24" MIN. NO MORE THAN 4" z ❑A TRANSITION BETWEEN FLOOR FINISHES CARPET PILE THICKNESS IS FROM 1 22" MIN. 3'-0" MIN. CLEAR � ACCESSIBLE ROUTE 0 FLOOR FINISH TO TOP OF PILE. — — — 2 OBJECT PROJECTION a FROM WALL LESS THAN N LATCH APPROACH LATCH APPROACH 27" ABOVE FINISH FLOOR PULL SIDE PULL SIDE MAY PROTRUDE ANY AMOUNT ]B THRESHOLD DOOR WITH CLOSER N Consultant FLOOR SHALL BE SLIP -RESISTANT SURFACE LATCH APPROACH LATCH APPROACH AND LEVEL WITH MAX 1/4" PUSH SIDE PUSH SIDE CHANGE IN LEVEL �C LEVEL CHANGES DOOR WITH CLOSER 1 CITY COMMENTS 5 5 2021 // 4> 48° MIN. PERMIT/BID 02-05-2021 z z =i> No. Issue Date INTERIOR ACCESS ROUTE CHANGES IN LEVEL 5 N.T.S. 3 N.T.S. v N 24" MIN. 24" MIN. �> -- <� 11204 D CORRESPONDING REACH HEIGHTS FOR GIVEN DEPTHS: CHIIT CT WHEN D = 10" OR LESS, H = 48" MAX. WHEN D = >10" TO 24" H = 46" MAX. DOORS IN SERIES TAtME [ 10" 30" 30" > 10"-24" Seal A) MAX. 24" MAX 25 MAX 48" MIN. 410* 635 PERMIT/BID 48" MIN. Store Number 20221 6 max Approved 150 Title 00 =zw ACCESSIBILITY X �O> X Q DETAILS �> _ 1� �I r co � O - o cv DOORS IN SERIES DOORS IN SERIES CV CONDIMENTS 1. 48 min Sheet 1220 ADA REACH RANGES ADA DOOR CLEARANCES ]= 11-01, C731 0 1 N.T.S. Municipal Approval Stamps EXISTING CEILING TO REMAIN 5/8" GYPSUM BOARD, - TYP. WALL FINISH, REFER TO FINISH SCHEDULE, TYP. SCH FLR & BASE FIN, SEE SCH, TYP SHOT PIN ANCHOR TRACK TO CONC SUBFLR PER MANUF SPEC CONT. 'C' SHAPED TRACK MTL STUD FRAMING PER SCH BELOW TYPICAL SIDE 2 5/8" GYPSUM BOARD, L: TYP. L: WALL FINISH, REFER TO FINISH SCHEDULE, TYP. o SOUND ATTENUATION BATT INSULATION, TYP. (WHERE OCCURS) CONT. 'C' SHAPED TRACK SCH FLR & BASE FIN, SEE SCH, TYP LINE OF FLR I SILICONE SEALANT j ; BELOW TRACK BOTH SIDES (TYP) PARTITION: 1 (INTERIOR WALL) TYPE STUD SIZE STUD SPACING FIRE RATING INSLUATION THICKNESS STUD GAUGE WALL THICKNESS STC RATING A 3-5/8" 16" OC N/A 0" 20 4-7/8" NOM N/A B 3-5/8" 16" OC N/A 3-1/2" 20 4-7/8" NOM N/A C 6" 16" OC N/A 0" 20 7-1/4" NOM N/A D 6" 16" OC N/A 6" 20 7-1/4" NOM N/A DATUM LINE: INTERIOR FACE OF EXIST DEMISE WAL PLAN ELECTRICAL DEVICES �3 +42" GFCI THREE-WAY LINE VOLTAGE SWITCH DUPLEX OUTLET - +42" INDICATES MOUNTING HEIGHT 110V 15 AMP DUPLEX OUTLET SPECIAL RECEPTACLE - CAT5E DATA OUTLET - RUNS TERM AT BOTH ENDS 220V 20 AMP DEDICATED SINGLE PHASE NEMA 6-20R WALLSOCKET WIREMOLD (TELEPOLE) 110V 15 AMP DUPLEX CAT5 CABLES SHOULD BE DROPPED FROM EACH LOCATION SPECIFIED AND TERMINATED AT EACH END. ALL CAT5 WIRES SHOULD BE TIED OFF WHERE INDICATED ON PLANS OR WHERE ISP SERVICE HUB WILL BE TERMINATED. 18" A.F.F. TO BOTTOM OF BOX, U.N.O. KEYNOTES ® SEE DOOR SCHEDULE ON SHEET A6-10 FOR MORE INFORMATION #X SEE PARTITION SCHEDULE ON SHEET A6-01 FOR MORE INFO EXISTING STOREFRONT TO REMAIN ❑2 ELECTRICAL PANEL -SEE ELEC DWGS FOR MORE INFO LEGEND EXISTING PARTITIONS & EXTERIOR WALLS NEW PARTITIONS EXISTING WALL W/ NEW FURRING BLOCKING NOTES PROVIDE FTWD BLOCKING (UON) AT THE FOLLOWING LOCATIONS: 1. ACCESSIBLITY REQUIREMENTS & GRAB BARS AT ALL RESTROOM LOCATIONS 2. RESTROOM ACCESSORIES INCLUDING TOILET STALL PARTITIONS & BABY CHANGING TABLE 3. MILLWORK LOCATIONS - TO BE 6" STRIPS 4. CASEWORK AS REQUIRED BY THE MFR & FOR PROPER SUPPORT 5. MANAGER'S DESK SHELVES 8. LOCKERS DIMENSION NOTES 1. DIMENSIONS ARE TO FACE OF EXISTING STOREFRONT FRAME, FINISHED EXTERIOR WALL & FINISHED FACE OF DEMISING WALL 2. ALL INTERIOR DIMENSIONS ORIGINATE FROM ESTABLISHED DATUM LINES. ESTABLISH DATUM LINES PRIOR TO LOCATING WALLS, DRAINS, FIXTURES, ETC. NOTE: ALL WOOD BLOCKING TO BE FIRE-RET TREATED. GC TO FIELD VERIFY ALL EXISTING DIMENSIONS & COLUMN LOCATIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. DIMENSIONED PLAN 1/4" = 1'-0" RESUBMITTED May 12 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT 1%w4'3igparamorwbTw-:- Client THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. SIGNARAMA 1414 S. 324TH ST. STE B201 FEDERAL WAY, WA Project A RRICCH�TECCTS 412 S. Wells Street - 2nd Floor - Chicago - IL 60607 P:3129550334 - d x u a r c h c o m Architect of Record Consultant 1 CITY COMMENTS 5/5/2021 PERMIT/BID 02-05-2021 No. Issue Date 1#2 A Seal TEa M+TECT 0,1LITR L4 O 6SHINGTONI - PERMIT/BID Store Number 20221 Approved Title DIMENSIONED Sheet FLOOR PLAN A2-11 _j Municipal Approval Stamps FINISH SCHEDULE FINISH DESCRIPTION FINISH NO. MFR MFR NO. COLOR TYPE REMARKS BASE VINYL BASE VB-1 ROPPE 700 #40073P195 LIGHT GREY COVE 4" HIGH, COVED CEILING CEILING PAINT PT-? - - - - FLOOR LAMINATE VINYL TILE LVT-1 TRAFFIC #775611 CAYMAN ASH - MASTER VINYL COMPOSITION ARMSTRONG CLSSIC BLACK OR TILE VCT-1 STANDARD 51910031 SIMILAR HOME 12"X12" IMPERIAL TEXTURE EXCELON DEPOT VINYL COMPOSITION VCT-2 ARMSTRONG 51899031 WHITE HOME 12"X12" IMPERIAL TEXTURE TILE STANDARD DEPOT REPLACE IF EXCELON NEEDED WALLS WALL PAINT PT-1 BEHR S-G-160 CALIFORNIA POPPY - SEE PLAN FOR WALL LOCATIONS WALL PAINT PT-2 GLIDDEN DUO GLD3000-01 WHITE SEMI -GLOSS TO BE USED ON ALL TRIM WALL PAINT PT-3 BEHR 790E-2 GENTILE RAIN - ALL WALLS UNLESS NOTED OTHERWISE FINISH NOTES - PAINTING CONTRACTOR TO PRIME ALL SURFACES, DO NOT PAINT - PRIMER AND FIRST COAT TO BE APPLIED BEFORE FLOORING INSTALLATION, FINAL COAT AFTER FLOORING INSTALLED - REMOVE EXISTING WALL COVERING FROM PERIMETER WALLS, PREPARE AS REQUIRED FRO PAINT FINISH - ALL HOLLOW METAL FRAMES TO BE PT-2 TYP. - REMOVE FLOORING AS REQUIRED AND REPAIR / PREPARE FLOOR SLAB FOR PROPER INSTALLATION OF NEW FLOOR MATERIALS - VINYL BASE NOTE: FIELD APPLY LAMINATE BASE; SCRIBE AS REQUIRED TO UNEVEN FLOORS. LEGEND NEW PARTITIONS EXISTING PARTITIONS & EXTERIOR WALLS EXISTING WALL W/ NEW FURRING - - - - - FULL HEIGHT WALL FINISHES PT-2 WALL FINISH DESIG. VB-1 BASE DESIGNATION N► FINISH &EQUIP. PLAN 1/4" = 1'-0" RESUBMITTED May 12 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT T�Signarama Client THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. SIGNARAMA 1414 S. 324TH ST. STE B201 FEDERAL WAY, WA Project A PtCCHITECCTS 412 S. Wells Street - 2nd Floor - Chicago - IL 60607 P:3129550334 - d x u a r c h c o m Architect of Record Consultant 1 1 CITY COMMENTS I 5/5/2021 PERMIT/BID I 02-05-2021 No. I Issue I Date Seal i#2t4 TERE D M+TECT 0,1LITR O L46SHI V TONI PERMIT/BID Store Number 20221 Approved Title FINISH & EQUIPMENT PLAN Sheet A2-13 _j Municipal Approval Stamps LIGHTING SCHEDULE SYMBOL TYPE QUANTITY MANUFACTURER MODEL FINISH LAMPS MOUNT ING NOTES EXISTING TO A 30 - _ _ REMIAN B 3 HALO 6130WH WHITE LED IN EXISTING CEILING TILE EZXTEU2RWEM WALL, SEE ® X 2 BEST MV, NON DIM, 4W WHITE LED RCP NOTES: 1. VERIFY CEILING OR HALL FOR ALL RECESSED LIGHTING FIXTURES AND COORDINATE WITH OWNER. 2. CONTRACTOR SHALL COORDINATE WITH ARCHITECTURAL DRAWINGS AND CEILING CONTRACTOR FOR EXACT LIGHTING FIXTURE LOCATIONS. KEYNOTES 1❑ NEW RECESSED CAN LIGHTS 2❑ EXISTING CEILING & LIGHT FIXTURES TO REMAIN ❑3 EXISTING CEILING LIGHT FIXTURES TO REMAIN REFLECTED CEILING NOTES 1. ALL GYP. BD. CEILING FINISHES P-4, SEE A9-02 FINISH SCH FOR MORE INFO 2. WHEN APPLICABLE, GC TO PROVIDE RECESSED SPRINKLERS HEADS W/ POLISHED CHROME ESCUTCHEONS CENTERED IN THE ACT. 3. ALARM SYSTEM TO BE LOCATED ABOVE CEILING. 4. CENTER EMERGENCY/EXIT LIGHTS ABOVE DOORS, UNO. 5. COORDINATE DUCT LOCATIONS AND DIFFUSER SIZES WITH MECHANICAL DWGS. N► REFLECTED CLNG PLAN 1 /4" = V-0" RESUBMITTED May 12 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT 1.4r.9fg►rarama Client THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. SIGNARAMA 1414 S. 324TH ST. STE B201 FEDERAL WAY, WA Project DX A RRICH�TECTS 412 S. Wells Street - 2nd Floor - Chicago - IL 60607 P:3129550334 - d x u a r c h c o m Architect of Record Consultant 1 1 CITY COMMENTS I 5/5/2021 I PERMIT/BID I 02-05-2021 No. I Issue I Date Seal i#2t4 TEa M+TECT 0,1LITR L4 O 6SHINGTONI - PERMIT/BID Store Number 20221 Approved Title REFLECTED Sheet CEILING PLAN A2-14 _j ELECTRICAL SPECIFICATIONS: Municipal Approval Stamps 1.0 SUMMARY & GENERAL REQUIREMENTS 1.1 The work under this division includes furnishing all labor, material and equipment necessary for the complete installation and operation of the electrical systems in accordance with electrical drawings and specifications. 1.2 All drawings are schematic in nature and the required installation is not limited to what is shown. All appurtenances necessary to provide a complete and operational system shall be included in the contractors bid and work. The work shall also include the completion of such minor details of electrical work not noted or shown which are necessary for the successful operation of all electrical systems described on the drawings or required by these specifications. 1.3 The contractor shall visit the job site and examine the drawings to familiarize himself with all existing conditions and new requirements which may effect his bid or work. No allowances will be made for existing conditions or the contractors failure to include cost of accommodating existing conditions. 1.4 It is contractors responsibility to obtain clarification of any apparent conflict or inconsistency in the drawings, specifications, or design prior to his bid, in writing with the engineer. Otherwise the contractor accepts responsibility to correct (at his cost) any such items to meet the intent as interpreted by the engineer. 1.5 The contractor shall coordinate and provide information as required to all serving utilities in a timely manner as necessary to provide the service required and meet utility requirements. Immediate coordination is required for most projects. Field coordinate all requirements with utility companies prior to trenching. 1.6 Refer to architectural, mechanical, civil, structural, and/or equipment suppliers drawings and specifications for exact equipment locations, loads and additional requirements. Representations of the work specific to the other disciplines is shown on the electrical drawings for clarity only. 1.7 Contractor shall be responsible to install all equipment per manufactures strict recommendations. Otherwise the contractor assumes responsibility (at his cost) to correct any installation not in compliance with the manufactures recommendations and as interpreted by the engineer. 1.8 Plan and install work in such a manner as to prevent obstructions, and keep openings and passageways clear. Review general contract drawings for conditions affecting this work and verify spaces in which work will be installed. Where interferences with structural, mechanical or otherwise exist, or where job conditions require reasonable changes in locations and arrangement of indicated equipment, conduit, outlets or wiring, the contractor shall make such changes without additional cost to owner, architect or engineer. 1.9 The contractor shall not interrupt or remove any existing circuits or equipment unless noted otherwise on plans. Any damaged or disrupted circuits or equipment shall be restored to like new condition at no additional cost to owner, architect or engineer. 1.10 All penetrations of fire -rated floors or shaft walls shall be protected by materials and installation details that conform to Underwriters Laboratories listings for "through -penetration fire stop systems." The contractor shall submit shop drawing details, furnished by the manufacturer of the fire stop material, which show complete conformance to the UL to the UL to the architect. The drawings shall by specific for each penetration, with all variables defined. 1.11 The contractor shall provide new, typed, panelboard directories for all new and/or existing panels within the scope of these project. The directories shall indicate the load type and area served. Provide all field verification work as necessary. 1.12 Contractor shall submit shop drawings for all new service entrance equipment panelboards, fusible switches, circuit breakers, disconnect switches, lighting fixtures, etc. that may be required for this project. 1.13 The final determination of exit lighting locations and egress pathways shall be the responsibility of the architect. The contractor shall confirm and verify the locations of all exit and emergency lights with the architect prior to any installations. 1.14 The contractor shall field verify the source of all existing lighting and power circuits (if applicable) by panel and circuit numbers, whether existing or new for the area and equipment in the scope of this project. 1.15 Electrical contractor shall coordinate all device and lighting fixture locations, finishes and dimensions with architect prior to purchasing any equipment. Also confirm the exact ceiling type prior to ordering any fixtures. 1.16 All branch circuits shall be minimum: #12 THHN/THWN copper with #12 copper equipment ground conductor in 1/2" conduit unless noted otherwise. All conductors, regardless of size shall be copper with 90 degree C insulation (THHN/THWN OR XHHW). All wiring shall be in conduit with NEC recommended sized equipment grounding conductors unless noted otherwise. 2.0 CODES AND PERMITS 2.1 All electrical material, equipment and work shall comply with the applicable edition of National Electrical Code, U.B.C., I.B.C., IECC, NFPA 72, 75, 101, adopted and enforced by the AHJ and local and state building codes and ordinacnces, Americans with disabilities Act, E.P.A., and utility company requirements. 2.2 The contractor is responsible to obtain all necessary permits, variances, and approvals, etc. (at his cost) which may be required for completion of this work. 3.0 EQUIPMENT AND MATERIAL 3.1 The Electrical Contractor shall provide all materials, equipment and accessories necessary, whether stated on drawings or not, to achieve the required completion and fully functional electrical system. 3.2 All equipment and material furnished under this section shall be new, except where noted otherwise on the drawings, and shall be the standard product of established manufactures regularly engaged in the production of such equipment. All materials, apparatus and equipment shall be new, of the best grade and subject to approval of the architect or engineer. All material used shall have the U.L. label when normally available. Installations shall be in accordance with the best practice of electrical trades and by skilled mechanics. 4.0 SERVICE ENTRANCE EQUIPMENT 4.1 Service entrance equipment distribution switchboards shall be the dead front type with molded circuit breakers or fusible switches as shown on drawings. Service entrance equipment and switchboards shall be UL label and shall have silver plated copper bussing for voltage and amperage rating as shown on drawings. Metering and primary pull section shall be borriered from other work and approved by local utility company and other authority having jurisdiction. 4.2 Contractor shall coordinate work with utility company and install per utility company requirements. 4.3 Service and distribution switchboards shall have full sized neutral and on -tapered bussing. All space shall be fully bussed for future use. 5.0 PANELBOARDS 5.1 Furnish and install lighting and appliance type panelboards as specified herein and as indicated on the drawings. All bus boards shall be copper, located in the rear of the panelboard cabinet. Circuit breakers shall bolt -on type and individually removable without disturbing other circuit breakers. Acceptable manufacturers are ABB(General Electric), EATON, Siemens, or Square D. 5.2 Minimum interrupting rating of circuit breakers shall be 10,000 amps unless noted otherwise on the drawings. 5.3 Verify mounting space prior to ordering. Panelboards shall be equal to Square-D. 5.4 Provide identification, labeling, and panelboard directories; as specified herin in section 19.0. 5.5 Panel boards shall be equipped with full neutral and ground busses. 5.6 All panel boards shall have hinged doors with lock. Locks for all panel boards shall be keyed alike. 5.7 Install panel boards straight and plumbed. Properly support and secure with centerline 5' above floor but top of panel board not to exceed 6' above floor. 5.8 All New circuit breakers for existing panel boards shall match the existing in manufacturer, type and A.I.C. rating unless noted otherwise on drawings. 5.9 Circuit breakers shall be switch rated and ambient compensated for all circuits. All lighting panels and circuit breakers shall be rated for continuous duty. 6.0 TRANSFORMERS : As noted on the drawings. 7.0 DISCONNECT SWITCHES AND STARTERS 7.1 Disconnect switches shall be heavy-duty, quick -make, quick -break, horsepower rated, NEMA 1 indoor, NEMA 3 gasketed NEMA 12 or NEMA 7 as applicable. Sized as shown on drawings, otherwise size equipment as recommended by NEC. NEMA 4x stainless steel when exposed in the food service area. 7.2 Manual motor starters with thermal overloads shall be provided for fractional horsepower motors 1 /3 HP or greater. 8.0 CONDUIT/RACEWAYS 8.1 All conductors shall be enclosed by conduit sized in accordance with the proper tables contained in the National Electric Code for the type of insulation used minimum 1/2" except for factory furnished lighting fixture flexible conduit may be 3/8". 8.1.1 Flexible metal conduit shall be utilized for all connections to vibrating equpment such as motors (minimum of 2'-0" - maximum of 6'-0"), connections to lay -in type light fixtures. 8.1.2 Rigid nonmetallic (PVC) Schedule 40 electrical conduit should be used for underground and under concrete slabe where permitted by NEC and local Electrical codes. 8.1.3 Electrical metallic tubing (EMT) shall be utilized for all dry, above grade or above floor applications in accordance with Article 384 of the National Electrical Code. Couplings and connectors shall be compression gland type made up wrench -tight. Set screw type are allowed subject to owner approval. Provide equipment ground conductor within all runs of EMT conduit. 8.2 All exposed conduit (including conduit installed in ceiling plenums) shall be routed parallel or perpendicular with the building walls. Support conduit as required by the National Electrical Code. 8.3 Care in placement of concealed conduit shall be used to prevent excessive bunching of conduits which will affect the conductor ampacity. 8.4 Provide expansion type fittings for all conduits which cross expansion joints. 9.0 CONDUCTORS 9.1 Minimum size shall be #12 AWG except for control circuits which may be #14 AWG or signal circuits which shall be as indicated. All conductors shall be copper with the 90 degree C insulation types as indicated on the drawings or as specified below. It shall be the contractors responsibility to determine and increase the conductor size as necessary to limit branch circuit voltage drop to a maximum or 3" and feeder voltage drop to a maximum of 2%. 9.2 Conductor insulation shall be of type recognized by the National Electrical Code and as approved for its particular application or as required by the Local Building Safety Authorities, whichever is more stringent. Unless noted otherwise on the drawings. Type THHN/THWN shall be used for all conductors smaller than #4 AWG and type XHHW for all conductors sized #4 AWG and larger. 9.3 Splices and make-up joints for #8 and smaller conductors shall be equal pressure type solder less connectors (Buchanan, Scotchlok, Wing Nut or as approved). Splices or make-up joints #6 AWG and larger shall be made using approved solder less type pressure connectors (Burndy or approved) or hydraulic compression type barrel splices when specified on the drawings. All uninsulated type splices shall be insulated using approved heat or cold shrink covers followed by an a minimum of three -lapped layers of plastic electrical tape (Scotch #33+). In addition splices or joints in damp or wet locations shall further be covered y three -lapped layers of rubber tape. Feeders larger than #6 AWG shall not be spliced (installed in one continuous run) unless specifically noted or implied on the drawings. 9.4 All wiring throughout shall be color coded as follows: 480 Volt System 208 Volt System A Phase Brown Black B Phase Orange Red C Phase Yellow Blue Neutral Grey White Ground Green Green Isolated Ground - - - - Green with Yellow Stripes 10.0 OUTLET BOXES 10.1 4" square or octagonal, zinc coated sheet steel boxes. 10.2 Provide 3/8" no -bolt fixture studs. 10.3 Provide plaster rings, covers and/or plates set to come flush with finish walls. 10.4 Utility or sectional switch boxes only where permitted. 11.0 DEVICES 11.1 All wiring devices shall be UL listed and labeled and of the type and number shown on the drawings. All new devices shall be 20 amp specification grade rated at 277V or 120V as applicable. 11.2 All devices shall be white color or as otherwise required by the architect or owner. It shall be the contractors responsibility to confirm all devices and plate colors with the architect or owner prior to purchase and installation. 11.2.1 Specification grade receptacles, Hubbell 5362 or equal by Leviton. 11.2.2 A.C. quiet operating type switches, Hubbell 2120 or equal by Leviton. 11.2.3 Provide receptacles having NEMA configuration that matches the NEMA configuration of the plug attached to the equipment being provided 11.3 Device plates shall be nylon or satin stainless steel , as manufactured by the device manufacturer. 11.4 Mount devices in accordance with the following schedule except where otherwise noted on the drawings: 11.4.1 Convenience receptacles with long axis vertical measure to center of outlet 18" A.F.F." 11.4.2 Light switches measure to top of box 48" A.F.F." 11.4.3 Telephone outlets measure to center of outlet 18" A.F.F." 12.1 Provide all new lighting fixtures complete with lamps, LED drivers, reflectors, plaster frames, louvers stem hangers, etc., and as described on the drawings, and is required for a complete installation. 12.2 Exit signs and emergency lighting shall conform with local code requirements. 12.3 All luminaries, lamps and lenses shall be thoroughly cleaned prior to final project acceptance. in addition all existing fixtures (if any) shall be relamped using new lamps to match the existing. 12.4 No portion of any light fixture mounted in a suspended grid type ceiling may be solely supported in any way by the ceiling grid or the wires or cables supporting the ceiling grid. All fixtures mounted in grid type ceiling shall be independently supported (suspended) at two (2) diagonal corners by wire, cable or other approved means within 6 inches of the corner. 13.0 MECHANICAL EQUIPMENT WIRING AND CONNECTION 13.1 Mechanical equipment motors and controls shall be furnished with mechanical equipment. Provide all disconnects, starters, fuses, etc. as required by the local authorities or as required to provide complete and operational system. 13.2 Provide feeder circuits to mechanical equipment and provide all connections. 13.3 Provide safety switches and/or thermal overload switches as required. 13.4 Provide all power (line voltage) wiring for mechanical equipment and provide all connections except for temperature control equipment, which will be wired by Mechanical Contractor. 14.0 TELEPHONE AND DATA SYSTEM 14.1 Provide and install a complete system of empty raceway (with pull line) and service conduits. As required by the local telephone company or supplier. Provide required/requested information to telephone company prior to installation. 16.0 GROUNDING 16.1 Furnish and install grounding and grounding conductors as specified herein and as shown on the drawings. 16.2 All panelboard cabinets, equipment, enclosures, and conduit system shall be grounded securely in accordance with pertinent sections of Article 250 of NEC, as amended by any local codes. Conductors shall be copper. All electrically operated equipment shall be bonded to the grounded conduit system. All non -current carrying conductive surfaces that are likely to become energized and subject to personal contact shall be grounded by one or more of the methods detailed in Article 250 NEC. All ground connections shall have clean contact surfaces. Install equipment grounding conductors in all conduit and make connections readily accessible for inspection. Furnish and install grounding electrodes as described on the drawings. 16.3 Grounded of metal raceways shall be assured by means of grounding bushings on feeder conduit terminations at the service entrance, distribution switchboards and panelboards, and by means of a continuous, stranded, copper grounding wire extended from the ground bus in the enclosure to the conduit grounding bushings. 16.4 A separate insulated equipment grounding conductor, sized per NEC 250-95, shall be installed in all conduits. rir/[iZ��_1►l�I�i7ZJ�:7�9�y 17.1 Contractor shall at all times keep the permises clear of waste materials and debris caused by their employees and operation. Equipment not required in the work shall be removed prior to the termination of the contact. fE:l[iil����_P►I�7I��yJXij►[iI� 18.1 Contractor shall test wiring and devices as sections are completed and shall correct all defects immediately at their own expense, including any damage to walls, ceilings, floor or other portions of the building which may result from replacing defective equipment. 18.2 Furnish all meters, cable, connections and apparatus necessary for making tests. 18.3 Test system for shorts and grounds. Faulty wiring shall be removed and replaced. Any device, apparatus or fixture installed showing substandard performance shall be removed and replaced as directed by the Engineer. 18.4 Megger all systems neutrals to ensure the neutral isnot grounded within the system. 18.5 After the electrical wiring system installation is completed and at such time as the Architect/Engineer or his authorized representative may direct, the Contractor shall conduct an operating test for approval. Equipment shall be demonstrated to operate in accordance with requirements of specifications. Test shall be performed in presence of Architect or his representative. �l[i>■� 3�I�n►[e] 19.1 Labels shall be engraved, black on white melamine plastic laminate. 1 /16" minimum thickness for signs up to 20 square inches or 8 inches long; 1/8" thick for larger sizes. Engraved legend shall be in white letters on black face with minimum 3/16" high letters. Labels shall be punched and fastened to equipment with aluminum rivets or self tapping stainless steel screws or number 10/32 stainless steel machine screws with nuts, flat and lock washers. 19.2 Label equipment with name, amperage, voltage, phase, and wires(i.e. Panel "A", 400A, 120/208, 3o, 4W). 19.3 Equipment to be labeled shall include disconnects, contactors, and timeswitches. Labelother equipment as noted on plans. PLiKiIIIIIIIIIL1111fil 20.1 The Electrical Contractor shall warranty all materials, equipment, and workmanship furnished by him to be free from defect for a period of one year. Electrical contractor shall make all replacements and corrections to defective material, equipment, and workmanship in a timely fashion with no additional cost to the owner. 21.0 DRAWINGS OF RECORD 21.1 Record drawings shall be submitted in accordance with and if required by Division 1 - General Requirements. ELECTRICAL SYMBOLS SYMBOL DESCRIPTION HOME RUN TO PANEL. CIRCUIT NUMBERS, PHASE, NEUTRAL AND GROUND A-1 CONDUCTORS INDICATED ALONG WITH ISOLATED GROUND CONDUCTOR IF APPLICABLE PARTIAL CIRCUIT A-1 �� $ SINGLE POLE SWITCH, +3'-10" OR AS NOTED $2 DOUBLE POLE, SINGLE THROW SWITCH, +3'-10" OR AS NOTED $3 THREE-WAY SWITCH, +3'-10" OR AS NOTED 0-10V DIMMER, +3'-10" OR AS NOTED $OS WALL MOUNTED OCCUPANCY SENSOR, +3'-10" OR AS NOTED $RO WALL MOUNTED OCCUPANCY SENSOR, +3'-10" OR AS NOTED, CONTROLLED BY ROOM CONTROLLER OS CEILING MOUNTED OCCUPANCY SENSOR RO CEILING MOUNTED OCCUPANCY SENSOR, CONTROLLED BY ROOM CONTROLLER PS CEILING MOUNTED INTERIOR DAYLIGHT HARVESTING PHOTOCELL SENSOR CONTROLLED BY ROOM CONTROLLER PP POWER PACK, INSTALLED ABOVE ACCESSIBLE CEILING DUPLEX RECEPTACLE, +18" OR AS NOTED GFI DUPLEX RECEPTACLE +18" OR AS NOTED QUADPLEX RECEPTACLE, +18" OR AS NOTED J114: GFI QUADPLEX RECEPTACLE, +18" OR AS NOTED �G GROUND FAULT INTERRUPTING RECEPTACLE, +18" OR AS NOTED }�W P �J WEATHERPROOF GROUND FAULT INTERRUPTING RECEPTACLE, +18" OR AS NOTED ® SPECIAL RECEPTACLE, NEMA STYLE AS NOTED, +18" OR AS NOTED �U USB CHARGING DUPLEX RECEPTACLE, +18" OR AS NOTED aCLG RECEPTACLE INSTALLED FLUSH IN CEILING SIGN SWITCHED RECEPTACLE FOR INTERIOR SIGNAGE, +100" OR AS NOTED, LABEL RECEPTACLE ACCORDINGLY �n SWITCHED RECEPTACLE FOR PARTY LIGHTS, +100" OR AS NOTED, LABEL RECEPTACLE ACCORDINGLY 0 JUNCTION BOX ❑� DISCONNECT SWITCH, TOP AT +6'-0" OR AS NOTED DISCONNECT SWITCH PROVIDE WITH EQUIPMENT © LIGHTING CONTACTOR, INSTALLED AS NOTED O TIME CLOCK, +6'-2" OR AS NOTED O EXTERIOR PHOTOCELL, INSTALLED ON ROOF FACING NORTH RMC ROOM CONTROLLER FP _LCI PLUG LOAD CONTROLLER ELECTRICALLY OPERATED DAMPER, PROVIDED BY MECHANICAL CONTRACTOR, WIRE BY ELECTRICAL CONTRACTOR (mos THERMOSTAT, TEMPERATURE SENSOR, CARBON DIOXIDE SENSOR AND HUMIDISTAT PROVIDED BY MECHANICAL CONTRACTOR, +3'-10" OR AS NOTED ❑� PUSHBUTTON, TOP AT +4'-6" OR AS NOTED CH DOOR BELL CHIME, +8'-0" OR AS NOTED ® TELEPHONE/DATA OUTLET, +18" WITH 1" CONDUIT TO ABOVE CEILING Q DATA OUTLET, +18" WITH 3/4" CONDUIT TO ABOVE CEILING +48" MOUNTING HEIGHT ABOVE FINISHED FLOOR TO CENTERLINE OF DEVICE TYP. TYPICAL FACP FIRE ALARM CONTROL PANEL, FLUSH MOUNTED, TOP AT +6'-0" ❑F MANUAL FIRE ALARM PULL STATION, +3'-10" PER ADA �F FIRE ALARM HORN/STROBE, +80" TO BOTTOM OF DEVICE PER ADA EXTERIOR WEATHERPROOF FIRE ALARM HORN, +10'-0" AFG -6- STROBE ONLY, +80" TO BOTTOM OF DEVICE PER ADA ALARM HORN/STROBE, CEILING MOUNTED TFFIRE STROBE ONLY, CEILING MOUNTED D AREA TYPE PHOTOELECTRIC SMOKE DETECTOR WITH SAMPLING TUBES AND REMOTE SD INDICATOR LIGHT MOUNTED FLUSH IN CEILING BELOW DETECTOR RESUBMITTED May 12 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT 19i"�rrpmp Client THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. SIGNARAMA 1414 S. 324TH ST. STE B201 FEDERAL WAY, WA Project A RRICH�TECTS 412 S. Wells Street in 2nd Floor o Chicago o IL � 60607 P3129550334 o dxuarch. c o m Architect of Record MISSOURI CA E Engineering Inc. 796 Merus Court T 636.349.1600 St. Louis, MO 63026 F 636.349.1730 CERTIFICATE OF AUTHORITY NO. 4002 Consultant 1 CITY COMMENTS 5/5/2021 PERMIT/BID 02-05-2021 No. Issue Date Seal ✓r��tELL Cl H 33096 Ell 05/06/2021 PERMIT/BID Store Number 20221 Approved Title ELECTRICAL SPECIFICATIONS Sheet EO.01 Municipal Approval Stamps Showroom GENERAL ELECTRICAL NOTES: ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH NATIONAL ELECTRICAL CODE AND STATE/LOCAL CODES INCLUDING AMENDMENTS AS ADOPTED AND ENFORCED BY THE AUTHORITY HAVING JURISDICTION. ALL ELECTRICAL EQUIPMENT SHALL BE RESTRAINED FOR SEISMIC FORCES IN ACCORDANCE WITH LOCAL BUILDING CODES. ALL CIRCUIT BREAKERS USED FOR LIGHTING CIRCUITS SHALL BE SWITCH DUTY RATED TYPE CIRCUIT BREAKERS. CIRCUIT BREAKERS USED TO SERVE HVAC EQUIPMENT SHALL BE TYPE HACR. VERIFY EXACT LOCATIONS OF ALL MILLWORK POWER AND DATA LOCATIONS IN FIELD WITH MILLWORK VENDOR. THE ELECTRICAL CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO BID TO FAMILIARIZE THEMSELVES AND VERIFY EXISTING CONDITIONS. THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE TENANT'S REPRESENTATIVE OF ANY DIFFERENCES PRIOR TO BIDDING. NO EXTRAS OR CHANGE ORDERS SHALL BE GIVEN FOR CONTRACTOR'S FAILURE TO VERIFY SITE CONDITIONS PRIOR TO BIDDING. VERIFY THE VOLTAGE/PHASE/AMPERAGE NAMEPLATE INFORMATION OF ALL EQUIPMENT DELIVERED TO THE SITE. NOTIFY THE OWNER'S REPRESENTATIVE OF ANY DIFFERENCES BETWEEN THE PLANS AND EQUIPMENT DELIVERED PRIOR TO PERFORMANCE OF ANY WORK. VERIFY LOADS ON EXISTING CIRCUITS AND PANELS BEFORE ADDING TO THEM. DO NOT OVERLOAD PANELS. CIRCUIT NUMBERS SHOWN ARE TO INDICATE CIRCUITING INTENTION. USED AVAILABLE CIRCUITS AND PROVIDE NEW BREAKERS AS REQUIRED, AND PROVIDE UPDATED PANEL DIRECTORIES. EXISTING PANEL SHALL BE LABELED TO IDENTIFY THE AVAILABLE FAULT CURRENT AVAILABLE AT THE PANEL AND THE ARC FLASH HAZARD AT THE PANEL IN ACCORDANCE WITH NEC REQUIREMENTS. PERFORM CALCULATIONS AS REQUIRED TO DETERMINE VALUES. ELECTRICAL POWER PLAN 1 /4" = V-0" EC TO PROVIDE NEW 200A NEMA 3R DISCONNECT SWITCH W/ 200A FUSES. EC TO PROVIDE (4)#3/0—CU & (1) IN 2"C. EC TO PROVIDE NEW 200A METER SOCKET. COORDINATE WITH LOCAL NEW PANEL'A' 120/208V UTILITY FOR INSTALLATION 30-4WIRE OF PROPERLY SIZED 200 AMP METER. \[;]Fl M.L.O. = EC TO PROVIDE NEW 200A NEMA 3R DISCONNECT SWITCH W/ 200A FUSES. ELECTRICAL RISER DIAGRAM 1 /4" = 1'-0" GAG IIIIIIIIIIII.. IN KEYED NOTES O EC TO PROVIDE NEW BREAKERS FOR EXISTING EQUIPMENT IN NEW PANEL. OEC TO PROVIDE (2)22OV, 20A, 1—POLE DEDICATED NEMA 6-20R RECEPTACLES. OCAT6 NETWORK WIRES TERMINATION POINT AT 60"AFF. OEC TO PROVIDE WIREMOLD TELE—POWER POLE FOR ROLL—X POWER. OEXISTING POWER CIRCUITS AND DEVICES IN THIS AREA TO REMAIN. NEW PANEL BOARD A SURFACE MOUNTED 42/22 K.A.I.C. SERIES RATED 120 208 VOLTS 3 PHASE 4 WIRE 200 AMP. BUS CIRCUIT BREAKER TYPE 200 MLP FED FROM DISC. CKT. NO. TRIP AMPS NO. POLE LOAD SERVED LOAD— V. A. LOAD SERVED NO. POLE TRIP AMPS CKT. NO. AO BO CO 1 20 1 76 LTG — EXISTING 5360 REC — SHOW WINDOW 20 1 2 3 20 1 LTG — EXISTING 1180 REC — SALES DESK 20 1 4 5 zo 1 LTG — EXISTING 720 REC — SLIMLINE 20 1 6 7 20 1 LTG — DISPLAY 180 REC — POS COUNTER 20 1 8 9 20 1 LTG — SIGNAGE 1180 > REC — SHOWROOM 20 1 10 11 20 1 SPARE 540 REC — WORKSHOP 20 1 12 13 20 1 SPARE 120o > REC — PLOTTER 20 1 14 15 20 1 SPARE 540 REC — DESIGN DESK 20 1 16 17 20 1 SPARE 1800 REC — XROLL 20 1 18 19 20 1 SPARE -- SPARE 20 1 20 21 20 1 SPARE -- SPARE 20 1 22 23 20 1 SPARE -- SPARE 20 1 24 25 20 1 SPARE -- SPARE 20 1 26 27 20 1 SPARE -- SPARE 20 1 28 29 20 1 SPARE -- SPARE 40 1 30 31 20 1 EXIST. — MISC. 250o > EXIST. — HANDDRYER 30 1 32 33 20 1 SPARE 3800 > EXIST. — HVAC 3800 40 2 34 35 20 2 REC — PLOTTER 36 37 1805;6 0 1800 18560 00 100 EXIST. — HVAC 20 3 38 39 20 2 REC — PLOTTER 40 41 1560 ADD 42 11826 10508 13028 LOAD DESCRIPTION DEMAND FACTOR D.F. VOLT — AMPS CONNECTED DEMAND LIGHTING 1.25 4422 5528 RECEPTACLES NEC 9440 9440 MOTORS NEC -- -- MISC. EQUIPMENT 1.00 6000 6000 KITCHEN EQUIPMENT 0.65 -- -- HVAC EQUIPMENT 1.00 15500 15500 TOTAL- 35362 36468 PANELBOARD LOAD = 36468 V.A. LO HAND LOCK "OFF/ON" CLAMP DEVICE HIGH LEG FULL LOAD AMPS = 102 A. HACR HEATING, AIR CONDITION AND REFRIGERATION RATED BKR G GROUND FAULT CIRCUIT INTERRUPTING BKR C# ROUTE CIRCUIT THROUGH CONTACTOR INDICATED C RESUBMITTED May 12 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT �;'rSign�rrper*pmFM p Client THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. SIGNARAMA 1414 S. 324TH ST. STE B201 FEDERAL WAY. WA Project DX A RRICH�TECTS 412 S. Wells Street o 2nd Floor o Chicago o IL o 60607 P3129550334 o dxuarch. c o m Architect of Record MISSOURI CA E Engineering Inc. 796 Merus Court T 636.349.1600 St. Louis, MO 63026 F 636.349.1730 CERTIFICATE OF AUTHORITY NO. 4002 Consultant 1 I CITY COMMENTS 1 5/5/2021 I PERMIT/BID I 02-05-2021 No. I Issue I Date Seal ✓r��tELL C� H 330% ►.LAM 05/06/2021 PERMIT/BID Store Number 20221 Approved Title Sheet ELECTRICAL POWER PLAN E1.01 / Municipal Approval Stamps C LG� 26' 8' 1 EM C 3 EM EX EX EX Al EX EX LX EX q-3 1 a H 3f 3a 3f 3a F 31A4NEL A CDOC X OS OS a b 5 OS OS e f - 1 5 H O C EM W A— 9q=g EX EX EX EX EX EX EX ti -- O b 1 H O c b EM 1 1 3a 3f 3a 3 5 W a e EM 5 EX 5 EX EX EX EX A5 X EX EX 4 5g 5g 5 5g 3f 3a 3 OS OS 9 h OS OS e f O EX EX EX EX EX EX EX EX h g5 3f 3 M O 5h 5g 5h 5g 5 5 5 EM 5 EM ELECTRICAL LIGHTING PLAN 1 /4" = 1'-01, LIGHTING FIXTURE SCHEDULE ID MANUFACTURER MODEL # LAMPS VOLTAGE WATTAGE REMARKS EXISTING 2x4 FLUORESCENT EX EXISTING LIGHT FIXTURE TO REMAIN. FLUORESCENT 120/277 96W EXISTING FLUORESCENT FIXTURE IN SPACE TO REMAIN. H HALO 6130WH LED 120/277 50W ADJUSTABLE, LED 'EYEBALL' FIXTURE W/ 50W LED PAR30S BULB. X BEST EZXTEU2RWEM LED 120/ 277 30W EXIT, SELF POWERED SINGLE/DOUBLE FACE, UNIVERSAL MV,NON DIM, 4W MOUNT, LED, RED ON WHITE, VERIFY COLORS EM LITHONIA ELM2—LED—W LED 120/277 1.8W BUG EYE LED UNIT WITH WHITE FINISH. A. INSTALLATION OF LIGHT FIXTURES SHALL BE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND APPLICABLE CODE REQUIREMENTS. B. VERIFY THE EXACT MOUNTING HEIGHT AND FINISH OF ALL LIGHTING FIXTURES WITH ARCHITECT PRIOR TO PLACING ORDER OR COMMENCING ROUGH —IN. C. LIGHT FIXTURES SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. D. ALL MEANS OF EGRESS LIGHTING AND EXIT SIGNS SHALL HAVE A MINIMUM OF 90 MINUTES BACKUP POWER. GENERAL ELECTRICAL NOTES: CONNECT EXIT SIGNS, EMERGENCY AND NIGHT LIGHTS TO AN UNSWITCHED LIGHTING CIRCUIT, NOT CONTROLLED BY ANY OCCUPANCY SENSORS, SWITCHES OR CONTACTORS. PROVIDE A DEDICATED NEUTRAL WITH ALL DIMMING SYSTEM CIRCUITS, NO COMMON NEUTRALS SHALL BE ALLOWED. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND DETAILS FOR THE EXACT LOCATION OF ALL LIGHTING FIXTURES AND ANY OTHER EQUIPMENT INSTALLED IN THE CEILING SYSTEM. VERIFY EXACT MOUNTING HEIGHTS AND FINISHES WITH ARCHITECT PRIOR TO ROUGH —IN. PROVIDE (2)ADDITIONAL #12 CONDUCTORS FOR ALL 0-10V DIMMING CIRCUITS. 18" MIN TO BOTTOM OF ALL ROUGH —IN BOXES FOR USER CONTROLLED SWITCHES, OUTLETS ETC. AND 48" MAC TO TOP OF ROUGH —IN BOX. KEYED NOTES CEXISTING LIGHTING AND CONTROLS IN THIS AREA TO REMAIN. O2 EC TO PROVIDE EXTERIOR WEATHERPROOF RECEPTACLE W/ TIMER FOR FACE SIGN. O3 CURRENT LIMITING DEVICE FOR EACH SECTION OF TRACK LIGHTING AS SHOWN AT J—BOX. CURRENT LIMITING AMPACITY AS INDICATED BY "#CL" AT JUNCTION BOX. EC SHALL COORDINATE FEED TYPE WITH INSTALLATION OF TRACK. O4 EC TO PROVIDE LOW VOLTAGE DUEL TECHNOLOGY CEILING MOUNTED OCCUPANCY SENSOR SWITCH CM—PDT9 & PP-15 POWER PACK. SENSOR SHALL ENERGIZE SWITCH FOR LOCAL CONTROL WHERE REQUIRED. O5 EC TO CONNECT EMERGENCY BATTERY DRIVER, EXIT SIGNS, AND NIL TO UNSWITCHED LEG OF LOCAL CIRCUIT INDICATED. RESUBMITTED May 12 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT 1176�Sign�rrpmpot FM p Client THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. SIGNARAMA 1414 S. 324TH ST. STE B201 FEDERAL WAY, WA Project A RRICH�TECTS 412 S. Wells Street o 2nd Floor o Chicago o IL o 60607 P3129550334 o dxuarch. c o m Architect of Record MISSOURI CA E Engineering Inc. 796 Merus Court T 636.349.1600 St. Louis, MO 63026 F 636.349.1730 CERTIFICATE OF AUTHORITY NO. 4002 Consultant 1 I CITY COMMENTS 1 5/5/2021 I PERMIT/BID I 02-05-2021 No. I Issue I Date Seal ✓r��tELL Cl co 330% ►.6 05/06/2021 PERMIT/BID Store Number 20221 Approved Title Sheet ELECTRICAL LIGHTING PLAN E2.01