Loading...
21-101714-CO SITE Plans33810 WEYERHAEUSER WAY S, SUITE 210 FEDERAL WAY, WASHINGTON W Ir D U Lu cc 2 U Q N a Lu N z_ F- H m z z W W W > O a U) � z C) z Q Z X W Lu ~ n n <C O N W uj Q N 00 p O N U c U 2 ¢ CC? y a. v y Lu Lu Z O 3 z y a pw Z� QU) a3: F~ (n _ Z� F IL Z Ow } w F w Lu w Lu C Oa CL } am wa =w ~O wX < Lu Q Y z = ZO O� F 0w U� a} U) Z pa ZM ¢O LL p Z w �Z) ¢w mm pF w0 () Z w J = J �a O 71, W ~ z �O Cl)� cz aCl) �a LLI DC cn>- =a W� a J IX =a W lz W 0 LL O O M M CO Y cz Q W cz Ir O Lu Q LL C) Lu U) Lu V / W N nro V / z Lu J W U W Cn Cc W O C� DATE: xxxx JOB NO.: SEA-21-011 ABBREVIATIONS & AND GA. GAUGE Z_ ANGLE GALV. GALVANIZED @ AT G.B. GRAB BAR 0 DIAMETER OR ROUND GL. GLASS # POUND OR NUMBER GND. GROUND (E) EXISTING GR. GRADE (R) RELOCATED GYP. GYPSUM (N) NEW H.B. HOSE BIBB A.B. ANCHOR BOLT H.C. HOLLOW CORE ACOUS. ACOUSTICAL HDWD. HARDWOOD A.D. AREA DRAIN HDWE. HARDWARE ADJ. ADJUSTABLE H.M. HOLLOW METAL AGGR. AGGREGATE HORIZ. HORIZONTAL AL. ALUMINUM HR. HOUR ALT. ALTERNATE HGT. HEIGHT A.P. ACCESS PANEL APPROX. APPROXIMATE I.D. INSIDE DIAMETER (DIM.) ARCH. ARCHITECTURAL INC. INCANDESCENT ASB. ASBESTOS INFO. INFORMATION ASPH. ASPHALT INSUL. INSULATION A.F.F. ABOVE FINISH FLOOR INT. INTERIOR INTER. INTERMEDIATE B.B. BULLETIN BOARD BD. BOARD JAN. JANITOR BITUM BITUMINOUS JT. JOINT BKG. BACKING BLDG. BUILDING KIT. KITCHEN BLK. BLOCK BLKG. BLOCKING LAB. LABORATORY BM. BEAM LAM. LAMINATE BOT. BOTTOM LAV. LAVATORY LKR. LOCKER CAB. CABINET LT. LIGHT C.B. CATCH BASIN CEM. CEMENT MAS. MASONRY CER. CERAMIC MAT. MATERIAL C.I. CAST IRON MAX. MAXIMUM C.G. CORNER GUARD M.B. MACHINE BOLT C.J. CONSTRUCTION JOINT M.C. MEDICINE CABINET CLG. CEILING MECH. MECHANICAL CLKG. CALKING MEMB. MEMBRANE CLO. CLOSET MET. METAL CLR. CLEAR MFR. MANUFACTURER C.O. CASED OPENING MH. MANHOLE COL. COLUMN MIN. MINIMUM CONC. CONCRETE MIR. MIRROR CONN. CONNECTION MISC. MISCELLANEOUS CONSTR. CONSTRUCTION M.O. MASONRY OPENING CONT. CONTINUOUS MTD. MOUNTED CORR. CORRIDOR MUL. MULLION CPT. CARPET CTSK COUNTERSUNK N. NORTH CNTR. COUNTER N.I.C. NOT IN CONTRACT CTR. CENTER NO. OR # NUMBER NOM. NOMINAL DET. DETAIL N.T.S. NOT TO SCALE DIA. DIAMETER DIM. DIMENSION O.A. OVERALL DISP. DISPENSER OBS. OBSCURE DN. DOWN O.C. ON CENTER D.O. DOOR OPENING O.D. OUTSIDE DIAMETER (DIM.) DR. DOOR OFF. OFFICE DWR. DRAWER O.H. OPPOSITE HAND IDS. DOWNSPOUT OPNG. OPENING D.S.P. DRY STANDPIPE OPP. OPPOSITE DWG. DRAWING P. PAINT E. EAST P.A.D. POWDER ACTUATED DEVICE EA. EACH PRCST. PRE -CAST E.B. EXPANSION BOLT PL. PLATE E.J. EXPANSION JOINT P.LAM. PLASTIC LAMINATE EL. ELEVATION PLAS. PLASTER ELEC. ELECTRICAL PLYWD. PLYWOOD ELEV. ELEVATOR PR. PAIR EMER. EMERGENCY PT. POINT ENCL. ENCLOSURE P.T.D. PAPER TOWEL DISPENSER ENGR. ENGINEER P.T.D/R COMBINATION PAPER TOWEL E.P. ELECTRICAL PANELBOARD DISPENSER & RECEPTACLE PARTITION EQ. EQUAL PTN. PARTITION EQPT. EQUIPMENT P.T.R. PAPER TOWEL RECEPTACLE E.W.C. ELECTRICAL WATER COOLER EXST. EXISTING Q.T. QUARRY TILE EXPO. EXPOSED QTY. QUANTITY EXP. EXPANSION EXT. EXTERIOR R. RISER RAID. RADIUS F.A. FIRE ALARM R.D. ROOF DRAIN F.B. FLAT BAR REF. REFERENCE F.D. FLOOR DRAIN REFR. REFRIGERATOR FDN. FOUNDATION RGTR. REGISTER F.E. FIRE EXTINGUISHER REINF. REINFORCED F.E.C. FIRE EXTINGUISHER CABINET REQ. REQUIRED F.H.C. FIRE HOSE CABINET RESIL. RESILIENT F.H.W.S. FLAT HEAD WOOD SCREW RM. ROOM FIN. FINISH R.O. ROUGH OPENING FIXT. FIXTURE RUB. RUBBER FL. FLOOR FLASH. FLASHING F.O.F. FACE OF FINISH FLUOR. FLUORESCENT F.O.S. FACE OF STUDS F.O.C. FACE OF CONCRETE F.O.SH. FACE OF SHEATING F.O.F. FACE OF FINISH FPRF. FIREPROOF F.O.S. FACE OF STUDS F.S. FULL SIZE F.O.SH. FACE OF SHEATING FT. FOOT OR FEET FPRF. FIREPROOF FTG. FOOTING F.S. FULL SIZE FT. FOOT OR FEET RWD. REDWOOD FTG. FOOTING R.W.L. RAIN WATER LEADER SYMBOLS LEGEND S. GAUGE S.A.D. GALVANIZED S.C. GRAB BAR S.C.D. GLASS SCHED. GROUND S.D. GRADE SECT. GYPSUM S.E.D. SEE ELECTRICAL DRAWING SH. SHELF SHR. SHOWER SHT. SHEET SIM. SIMILAR S.M.D. SEE MECHANICAL DRAWING S.M.S. SHEET METAL SCREW S.N.D. SANITARY NAPKIN DISPENSER S.N.R. SANITARY NAPKIN RECEPTACLE SPEC. SPECIFICATION S.P.D. SEE PLUMBING DRAWING SQ. SQUARE S.S.D. SEE STRUCTURAL DRAWING S.ST. STAINLESS STEEL S.SK. SERVICE SINK STA. STATION STD. STANDARD STL. STEEL STOR. STORAGE STRL. STRUCTURAL SUSP. SUSPENDED SYM. SYMMETRICAL TRD. TREAD T.B. TOWEL BAR T.C. TOP OF CURB TEL. TELEPHONE TER. TERRAZZO T.&G. TONGUE AND GROOVE THK. THICK THRES. THRESHOLD T.O.PV. TOP OF PAVEMENT T.O.P. TOP OF PARAPET T.O.SH. TOP OF SHEATING T.P.B. TELEPHONE PANELBOARD T.P.D. TOILET PAPER DISPENSER T.V. TELEVISION T.O.W. TOP OF WALL TYP. TYPICAL UNF. UNFINISHED U.O.N. UNLESS OTHERWISE NOTED UR. URINAL V.C.T. VINYL COMPOSITION TILE VERT. VERTICAL VEST VESTIBULE V.I.F. VERIFY IN FIELD W. WEST W/ WITH WC. WAL COVERING W.C. WATER CLOSET WD WOOD W.F. WIDE FLANGE W.O. WHERE OCCURS W/0 WITHOUT WP. WATERPROOF WSCT. WAINSCOT WT. WEIGHT W.R. WATER RESISTANT ROOM NAME 1 101 ROOM NAME/NUMBER 1 A3.1 SINGLE VIEW ELEVATION +10-�► CEILING HEIGHT 101 • DOOR NUMBER 1 1 A101 1 MULTI VIEW ELEVATION W1 WINDOW NUMBER 1 �A KEYNOTE �1� �1� BUILDING SECTION A3.1 A3.1 OWALL TYPE �1 EQUIPMENT A3.1 WALL SECTION PLUMBING 1 A3.1 DETAIL REFERENCE REVISION NUMBER CDREVISION CLOUD 1 / A101 DETAIL REFERENCE 1 � l J A3.1 ENLARGED PLAN REFERENCE 9 3217th & CD e M 0 � r r r VICINITY MAP Northwest Kldney Centers 9 Ae rotA 15 Li L_ EV GENERAL NOTES 17HIS PROJECT AND ALL WORK ASSOCIATED WITH THE PROJECT SHALL CONFORM TO STATE AND LOCAL CODE JURISDICTIONS. 2. THE TERM ARCHITECT OR DESIGNER AS USED IN THESE DOCUMENTS SHALL REFER TO TWINSTEPS. 3. THE ARCHITECT SHALL NOT HAVE CONTROL OR CHARGE OF AND SHALL NOT BE RESPONSIBLE FOR MEANS, METHODS, TECHNIQUES, SEQUENCE ON PROCEDURE, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, ALL WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 4. SHORING, TEMPORARY SUPPORTS, AND SAFETY OF ERECTION BRACING DURING DEMOLITION AND / OR CONSTRUCTION IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND HAS NOT BEEN CONSIDERED BY THE STRUCTURAL ENGINEER OR THE ARCHITECT. 5. ALL WORK NOTED "N.I.C." OR "NOT IN CONTRACT" IS TO BE ACCOMPLISHED BY A CONTRACTOR OTHER THAN THE GENERAL CONTRACTOR AND IS NOT TO BE PART OF THE CONSTRUCTION AGREEMENT. THE GENERAL CONTRACTOR SHALL COORDINATE WITH "OTHER"CONTRACTORS PER REQUIREMENTS ESTABLISHED BY THE OWNER AND TENANT. 6. THE GENERAL CONTRACTOR AND ALL SUB CONTRACTORS ARE RESPONSIBLE FOR EXAMINING CONTRACT DOCUMENTS, FIELD CONDITIONS, AND CONFIRMING THAT WORK IS BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IF THERE ARE ANY QUESTIONS REGARDING THESE OR OTHER COORDINATION ITEMS, THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH WORK IN QUESTIONS OR RELATED WORK. 7. CONTRACTOR SHALL MAINTAIN RECORD DOCUMENTS OF CONSTRUCTION CHANGES (AS -BUILT DRAWINGS) AND SHALL PROVIDE SAID DOCUMENTATION TO THE ARCHITECT UPON COMPLETION OF CONSTRUCTION. 8. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR TO COORDINATE WITH ALL SUB CONTRACTORS PER REQUIREMENTS ESTABLISHED BY THE OWNER, TENANT OR BOTH WHICH ARE UNDER SEPARATE CONTRACT WITH THE OWNER, TENANT, OR BOTH. 9. THE STRUCTURAL, ELECTRICAL, MECHANICAL, & PLUMBING & OTHER DRAWINGS AND JOB SPECIFICATIONS ARE SUPPLEMENTARY TO THE ARCHITECTURAL CONSTRUCTION DRAWINGS. ANY DISCREPANCY BETWEEN THESE DOCUMENTS SHALL BE IMMEDIATELY BRIGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION. 10. THE INTENT OF DRAWINGS AND SPECIFICATIONS IS TO INCLUDE ALL LABOR, MATERIALS & SERVICES NECESSARY FOR THE COMPLETION OF ALL WORK SHOWN, DESCRIBED, OR REASONABLY IMPLIED, BUT NOT LIMITED TO THAT EXPLICITLY INDICATED ON THE CONTRACT DOCUMENTS. 11. INSTALL ALL MANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT IN STRICT ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS, UNLESS NOTED OTHERWISE. 12. ANY WORK INSTALLED IN CONFLICT WITH THE CONSTRUCTION DRAWINGS, WITHOUT THE PRIOR APPROVAL OF THE OWNER AND THE ARCHITECT SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. 13. THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY SPECIFIED MATERIALS OR EQUIPMENT WHICH ARE EITHER UNAVAILABLE OR THAT WILL CAUSE A DELAY IN THE CONSTRUCTION COMPLETION SCHEDULE. THE CONTRACTOR SHALL SUBMIT CONFIRMATIONS OF DELIVERY DATES FOR ORDERS OF MATERIALS AND EQUIPMENT HAVING LONG LEAD TIMES. 14. ALL REQUESTS FOR SUBSTITUTIONS OF ITEMS SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT. SUBSTITUTIONS SHALL BE OF EQUAL QUALITY. 15. UNLESS OTHERWISE NOTED IN THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL SUBMIT 3 SETS OF SHOP DRAWINGS. FABRICATION SHALL NOT BEGIN UNTIL AFTER RECEIVING THE ARCHITECT'S OR ENGINEER'S APPROVAL. 16. THE ARCHITECT'S REVIEW OF SHOP DRAWINGS SHALL NOT RELIEVE THE GENERAL CONTRACTOR OR SUBCONTRACTOR FROM RESPONSIBILITY FOR DEVIATIONS FROM THE DRAWINGS AND SPECIFICATIONS UNLESS HE HAS, IN WRITING, AND BROUGHT TO THE ATTENTION OF THE ARCHITECT SUCH DEVIATIONS AT THE TIME OF THE SUBMISSION, NOR SHALL IT RELIEVE HIM FROM RESPONSIBILITY FOR ERRORS OF ANY SORT IN THE SHOP DRAWINGS. 17. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED BUILDING PERMITS PRIOR TO STARTING CONSTRUCTION. 18. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, THE APPLICANT SHALL HAVE EVIDENCE OF CURRENT WORKMAN'S COMPENSATION INSURANCE COVERAGE ON FILE WITH THE STATE LABOR CODES. 19. PROVIDE CONTINUOUS INSPECTIONS AS SET FORTH IN LOCAL AND STATE CODES AND PER THE CONTRACT DOCUMENTS AS NEEDED. 20. PRIOR TO THE ISSUANCE OF FINAL CERTIFICATE OF OCCUPANCY FOR THIS PROJECT, THE GENERAL CONTRACTOR SHALL SUBMIT A SIGNED CERTIFICATE TO THE DEPARTMENT OF BUILDING & SAFETY STATING THAT ALL WORK HAS BEEN PERFORMED AND MATERIALS INSTALLED ACCORDING TO THE PLANS AND SPECIFICATIONS AFFECTING NON-RESIDENTIAL ENERGY. 21. WHERE EXISTING TENANTS ARE ADJACENT TO THE JOB SITE, THE CONTRACTOR SHALL MINIMIZE CONSTRUCTION NOISE. EXTREME CONSTRUCTION NOISE SHALL OCCUR ON NON -TYPICAL BUSINESS HOURS. CONTRACTOR SHALL NOTIFY THE BUILDING REPRESENTATIVE OF SPECIAL CIRCUMSTANCES PRIOR TO WORK. 22. THE CONTRACTOR, AT HIS OWN EXPENSE, SHALL KEEP THE PROJECT AND SURROUNDING AREAS FREE FROM DUST AND DEBRIS. THE WORK SHALL BE INC CONFORMANCE WITH THE AIR & WATER POLLUTION CONTROL STANDARDS AND REGULATIONS OF THE STATE DEPARTMENT OF HEALTH. 23. CONSTRUCTION WASTE & DEBRIS SHALL BE DEPOSITED AT AN APPROPRIATE SITE. 24. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE GENERAL CLEANING OF THE JOB AFTER COMPLETION. 25. THE CONTRACTOR SHALL PROVIDE PEDESTRIAN PROTECTION, WHERE REQUIRED PER STATE AND LOCAL CODES. 26. IF TRENCHES OR EXCAVATIONS 5-0" OR MORE IN DEPTH ARE REQUIRE, OBTAIN A BUILDING OR GRADING PERMIT. 27. NO HAZARDOUS MATERIALS SHALL BE USED OR STORED WITHIN THE BUILDING WHICH DOES NOT COMPLY WITH THE LOCAL FIRE AUTHORITY AND STATE & COUNTY REQUIREMENTS. 28. THE CONTRACTOR IS RESPONSIBLE FOR BLOCKING OFF SUPPLY & RETURN AIR GRILLES & DUCTS TO KEEP DUST FROM ENTERING INTO THE BUILDING DISTRIBUTION SYSTEMS. 29. ALL CONSTRUCTION & DEMOLITION SHALL BE DONE IN ACCORDANCE WITH LOCAL & STATE CODES. 30. UNLESS OTHERWISE NOTED OR INDICATED, ALL DIMENSIONS ON THESE DOCUMENTS SHALL BE TO FACE OF CURB, FACE OF CONCRETE, FACE OF FINISH OR CENTERLINE OF GRIDS. 31. ALL VERTICAL DIMENSIONS SHOWN ARE FROM FLOOR SLAB, UNLESS NOTED OTHERWISE. 32. DIMENSIONS TAKE PRECEDENCE. DO NOT SCALE THE DRAWINGS. LARGER DETAILED DRAWINGS TAKE PRECEDENCE OVER SMALLER SCALED DRAWINGS. 33. WHERE ELECTRICAL, MECHANICAL, OR PLUMBING ITEMS PENETRATE A FOOTING, SLAB, WALL CEILING ETC. IT IS REQUIRED THAT AN APPROPRIATELY SIZED OPENING OR CLEARANCE BE FURNISHED. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL ITEMS WITH THE CONSTRUCTION DOCUMENTS PRIOR TO THE INSTALLATION. ANY CONFLICT WITH THE CONSTRUCTIONS DOCUMENTS, SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION IMMEDIATELY. 34. THE CONTRACTOR SHALL PROVIDE AND LOCATE ACCESS PANELS IN WALLS & CEILING CONSTRUCTION AS REQUIRED TO PROVIDE ACCESS TO FIRE SPRINKLER, MECHANICAL, PLUMBING & ELECTRICAL WORK. CONTRACTOR SHALL SUBMIT A PLAN OF ALL PROPOSED ACCESS PANEL TO THE ARCHITECT FOR APPROVAL. SITE 35. ALL PENETRATIONS AT RATED CONSTRUCTION SHALL BE PROTECTED TO MAINTAIN RATING 36. INTERIOR WALLS & CEILINGS SHALL BE INSTALLED IN ACCORDANCE TO STATE & LOCAL CODES, INCLUDING REQUIREMENTS FOR FLAME SPREAD AND SMOKE DENSITY RATINGS FOR FINISH MATERIALS. 37. ALL NEW CONSTRUCTION MATERIALS SHALL BE 100% ASBESTOS FREE. 38. ALL INSPECTIONS SHALL BE CALLED FOR AND PASSED BEFORE ANY WORK CONTINUES TO THE NEXT PHASE. 39. MANDATORY SPECIAL INSPECTIONS PER THE REQUIREMENTS OF THE ENGINEERING SUBMITTED AND I.C.C. PORTIONS OF THIS PROJECT REQUIRE SPECIAL INSPECTION. 40. NO ROOFTOP EQUIPMENT SHALL BE VISIBLE FROM THE GROUND. 41. A 4'-0" WALKWAY WILL BE MAINTAINED ALONG THE SIDE WALK IN FRONT OF THE BUILDING SITE DURING CONSTRUCTION. 42. PEDESTRIAN PROTECTION, FENCES, RAILING OR CANOPIES, SHALL BE ALONG THE PUBLIC RIGHT OF WAY IN ACCORDANCE WITH C.B.C. 43. A CONSTRUCTION FENCE SHALL BE MAINTAINED ALONG THE SIDE WALK IN FRONT OF THE BUILDING SITE DURING CONSTRUCTION. THIS FENCE SHALL BE INSTALLED PRIOR TO EXCAVATION AND/OR FOUNDATION TRENCHING. 44. TEMPORARY TOILET FACILITIES SHALL BE ON SITE DURING THE CONSTRUCTION AND WILL BE AVAILABLE ALL DURING CONSTRUCTION TIMES. 45. CONTRACTOR SHALL NOT SCALE, DERIVE, OR REQUEST DIMENSIONS FROM THE STRUCTURAL ENGINEER, ELECTRICAL ENGINEER, MECHANICAL ENGINEER, PLUMBING ENGINEER, OR CIVIL ENGINEER, ETC. FOR ANY ITEMS ON THE DOCUMENTS. ALL DIMENSIONS NEEDED WILL BE REQUESTED OF THE ARCHITECT "IN WRITING" IN THE FORM OF AN RFI. (FAILURE TO ADHERE TO THIS PROCESS WILL RESULT IN DENIAL OF CHANGE ORDERS) FIRE AUTHORITY NOTES 1. FINAL INSPECTION BY THE FIRE DEPARTMENT IS REQUIRED - SCHEDULE 72 HOURS IN ADVANCE 2. THE PROJECT ADDRESS SHALL BE PROVIDED IN A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET FRONTING THE PROPERTY PER LOCAL FIRE DEPARTMENT STANDARDS. 3. AN UNOBSTRUCTED ALL WEATHER FIRE APPARATUS ACCESS ROAD SHALL BE IN PLACE PRIOR TO THE DELIVERY OF COMBUSTIBLE BUILDING MATERIALS. 4. FIRE PREVENTION WATER SERVICE SHALL BE IN SERVICE PRIOR TO DELIVERY OF COMBUSTIBLE BUILDING MATERIALS. 5. ACCESS / SECURITY GATES SHALL BE APPROVED PRIOR TO INSTALLATION AND SHALL COMPLY WITH LOCAL FIRE CODES. 6. FIRE SPRINKLER SYSTEMS, WHEN PROVIDED, SHALL MEET STATE & LOCAL FIRE CODES. 7. INSTALLATION OF FIRE ALARM SYSTEM SHALL BE IN ACCORDANCE WITH STATE & LOCAL CODES. 8. LOCATIONS & CLASSIFICATIONS OF FIRE EXTINGUISHERS SHALL BE IN ACCORDANCE WITH STATE & LOCAL FIRE CODES AND PLACEMENT IS SUBJECT TO THE APPROVAL OF THE FIRE INSPECTOR. VERIFY QUANTITY AND EXACT LOCATION FROM FIRE DEPARTMENT PRIOR TO ORDERING. 9. AT LEAST 1 FIRE EXTINGUISHER WITH A MINIMUM RATING OR 2-A-10B:C SHALL BE PROVIDED WITHIN 75 FEET MAXIMUM TRAVEL DISTANCE FOR EACH 3,000 SF OR PORTION THERE OF. 10. STORAGE, DISPENSING, OR USE OF ANY FLAMMABLE AND COMBUSTIBLE LIQUIDS OR GASES, AND OTHER HAZARDOUS MATERIALS SHALL COMPLY WITH STATE & LOCAL FIRE CODES. THE STORAGE AND USE OF HAZARDOUS MATERIALS SHALL BE APPROVED BY THE FIRE AUTHORITY PRIOR TO ANY MATERIALS BEING STORED OR USED ON SITE. A SEPARATE PERMIT IS REQUIRED. 11. BUILDING NOT APPROVED FOR HIGH PILED STORAGE. A SEPARATE PERMIT IS REQUIRED FOR HIGH PILED STORAGE. PROJECT DATA BUILDING DEPARTMENT: CITY OF --- BUILDING CODES: 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA MECHANICAL CODE 2019 CALIFORNIA PLUMBING CODE 2019 CALIFORNIA GREEN BUILDING CODE 2019 CALIFORNIA ENERGY CODE 2019 FIRE CODE TITLE 24 (ADA) ADMINISTRATIVE CODE OCCUPANCY CLASSIFICATION OCCUPANCY SEPARATION: NONE TYPE OF CONSTRUCTION: 3-N, FULLY SPRINKLERED SPRINKLERS: YES NUMBER OF STORIES: X PROJECT AREA: +/ 30,199 SF TOTAL FIRST FLOOR AREA: +/- 5026 SF APN: XXXX-XXX-XXX PROJECT DESCRIPTION TENANT IMPROVMENT FOR ---. AREA TO BE REMODELED, +/- XXXX SQ.FT. OF XXXX SQ.FT. DEFERED SUBMITTALS DEFERRED SUBMITTALS THAT ARE NOT SUBMITTED AT THE TIME OF THE APPLICATION MUST HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE REVIEWED BY THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTIFICATION INDICATING THAT THEY HAVE BEEN REVIEWED AND ARE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. 1. EXTERIOR BUILDING SIGNAGE 2. FIRE SPRINKLER SYSTEM 3. FIRE MONITORING SYSTEM (IF NEEDED) 4. FIRE ALARM SYSTEM (IF NEEDED) SHEET INDEX ARCHITECTURAL A0.0 COVER SHEET A0.1 SHEET INDEX & SYMBOLS A0.4a ACCESSIBILITY DETAILS A0.4b ACCESSIBILITY DETAILS A1.0 SITE PLAN - OVERALL A1.1 FLOOR DEMOLITION PLAN A1.2 REFLECTED CEILING DEMOLITION PLAN A2.0 EXITING AND OCCUPANCY ANALYSIS PLAN A2.1 FLOOR PLAN All POWER AND DATA PLAN A4.1 FINISH PLAN A5.1 CEILING PLAN A8.3 INTERIOR ELEVATIONS A9.1 DOOR SCHED, TYPES, HARDWARE, NOTES & DETAILS A10.2 WALL & CEILING DETAILS A10.5 MILLWORK DETAILS STRUCTURAL S Unnamed SK1 SKETCH1 ELECTRICAL E-1.0 ELECTRICAL SYMBOLS DETAILS AND NOTES E-2.0 ENLARGED ELECTRICAL LIGHTING PLAN PLUMBING P-1 PLUMBING LEGEND, SCHEDULE & NOTES P-2 PLUMBING WASTE & VENT P-3 PLUMBING WATER P-4 PLUMBING ISOMETRIC PFP1 PROPOSED FLOOR PLAN MECHANICAL M-1 LEGENDS, SCHEDULES & NOTES M-2 HVAC DEMO PLAN M-3 HVAC FLOOR PLAN M-4 TITLE 24 W Cc D U W U 2 Q U) n W U) Z_ ui N m z uj ow zw aZ 0- W F Z� 0 W F 2 W �w w� d¢ EL } dm W d = W w0 W X � W ¢Y z z0� o� ¢w Uw EL F w0 a> U)¢ 0 <0 �w 3:, aW �m of w0 U)z W J 2 J 0 N W U)~ Z F- � O z cn W LV M >-_ z Lu a � cn 0 Q Lu z G H � a� Q V J Q = Q X W W Q LU F- wW LL 0 T co M M W Y a W O IL Lu 0 a o W U) > w U) cc V) V) Lu Q J 0 0 Q cf) z ob Lu x U LV 0 z F_ W W Z U) DATE: xxxx JOB NO.: SEA-21-011 N N 20" MAX >20-25" MAX 24" MIN 48"MIN 24" MIN FIGURE 11B-302.2 5" MAX 15"MIN CARPET PILE HEIGHT 3z z ) z z cG co co co 00 co co T V V FIGURE 1113-303.2 \s VERTICAL CHANGE IN LEVEL o Z o o M M z_ Lo 2 FIGURE 1113-602.5 DRINKING FOUNTAIN SPOUT LOCATION (A) (g) 10" MA >10 24" MAX FIGURE 1113-303.2 (A) (B) 10" MAX 0 BEVELED CHANGE IN LEVEL N W FIGURE 1113-308.2.1 FIGURE 1113-308.2.2 FIGURE 11B-308.3.2 FIGURE 1113-308.3.1 FIGURE 1113-403.5.1 ' ^ � Z UNOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH OBSTRUCTED HIGH SIDE REACH UNOBSTRUCTED SIDE REACH CLEAR WIDTH OF AN ACCESSIBLE ROUTE U) F— � O z W cnz W Qcn O �Q F F- a W ., ) �a z 18" MIN AT INTERIOR Z W 24"MIN AT EXTERIOR z 12" MIN z co o Q co Li 48"MIN 48" � 48"MIN 00 Q Z W bo Tllzl�22" MIN 24" MIN X W W < �� -- <� X w ~ W 13 W (A) 0 PULL SIDE (q) (g) (C) (p) T==* r FRONT APPROACH SIDE APPROACH POCKET OR HINGE APPROACH STOP OR LATCH APPROACH 0 M co (B) (C) PUSH SIDE PUSH SIDE, DOOR PROVIDED WITH BOTH CLOSER AND LATCH FIGURE 11B-404.2.4.3 FIGURE 11B-404.2.6 FIGURE 11B-404.2.4.2 MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES DOORS IN SERIES AND GATES IN SERIES MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS Y a w w TABLE 11 B-404.2.4.1 MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS AND GATES TYPE OF USE MINIMUM MANEUVERING CLEARANCE O PARALLEL TO DOORWAY APPROACH DIRECTION DOOR TO GATE SIDE PERPENDICULAR TO DOORWAY BEYONG LATCH SIDE UNLESS z z z ( NOTED) z 12" z v 5 — 18" MIN (ADD 6" � z T 2 T FROM FRONT PULL 60 INCHES 18 INCHES MIN 0 24" MIN 24 MIN 24" MIN 1 � AT EXTERIOR CD 22" MIN 22 MIN co FROM FRONT PUSH 48 INCHES 0 INCHES SIDE OF 36 MIN EXTERIOR FROM HINGE SIDE PULL 60 INCHES 36 INCHES DOOR) �O w 47 FROM HINGE SIDE PUSH 44 INCHES 2 22 INCHES 3 Q o W FROM LATCH SIDE PULL 60 INCHES 24 INCHES FROM LATCH SIDE PUSH 44 INCHES 4 24 INCHES u�, � w 1. ADD 12 INCHES IF CLOSER AND LATCH ARE PROVIDED. 2. ADD 4 INCHES IF CLOSER AND LATCH ARE PROVIDED. 3. BEYOND HINGE SIDE. (C) (G) (K) 4. ADD 4 INCHES IF CLOSER IS PROVIDED. (A) (B) FRONT APPROACH, PUSH SIDE, (D) (E) (F) HINGE APPROACH, PUSH SIDE, DOOR (H) (I) (J) LATCH APPROACH, PUSH SIDE, 5. ADD 6 INCHES AT EXTERIOR SIDE OF EXTERIOR DOORS. FRONT APPROACH, PULL SIDE FRONT APPROACH, PUSH SIDE DOOR PROVIDED WITH BOTH CLOSER AND LATCH HINGE APPROACH, PULL SIDE NOT USED HINGE APPROACH, PUSH SIDE PROVIDED WITH BOTH CLOSER AND LATCH LATCH APPROACH, PULL SIDE NOT SUED LATCH APPROACH, PUSH SIDE DOOR PROVIDED WITH BOTH CLOSER FIGURE 11B-404.2.4.1 (%) MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES (n uj J cn Q J_ TOP DIAMETER OF Q Q 0.45-0.47 AREA OF BASE DIAMETER �, WI RARY ,� E o OF 0.9-0.92 0 ® Z � AREA 0 F 32"MIN 32"MIN w (ELEVATION) Z � AREA OF REFUGE o U ENLARGED o REFUGE �° J 0 (B) m 2.3-2.4 N J MEN N `� SLIDING DOOR c� Lo N CENTERED ON NOT IN PICTOGRAM � M � \ 2 32"MIN U) o_0 0 TACTILE CHARACTERS •• FIELD L0 o z (A) W O 18"MIN • •• o o 0 01 to o HINGED DOOR v 00 O O O O (C) V FOLDING DOOR Q (B) - --- PLAN \ DATE: xxxx FIGURE 11B-703.6.1 �, FIGURE 11B-404.2.3 JOB NO.: PICTOGRAM FIELD CLEAR WIDTH OF DOORWAYS SEA-21-011 FIGURE 11B-705.1.1.2 FIGURE 11B-703.4.2 FIGURE 11B-703.2.5 FIGURE 11B-703.3.2 FIGURE 1113-703.4.1 SIZE AND SPACING OF TRUNCATED DOMES LOCATION OF TACTILE SIGNS AT DOORS HEIGHT OF RAISED CHARACTERS POSITION OF BRAILLE HEIGHT OF TACTILE CHARACTERS ABOVE FINISH FLOOR OR GROUND N 7 O g g a 48" MIN a U) 72"MIN 60" MIN 60" MIN oof IDENTIFICATION SIGN a ^ z� w (0 z ACCESS AISLE 0- o a W Q BOTTOM RAMP RUN LANDING RAMP RUN � J ' W o LANDING z � BLUE BORDER Y w a d= LANDING Q N HATCHED LINES AT a 0 o N 00 N �Y 00000000000000000000 LU z 36 INCHES ON o = o W w A B CENTER MAX = a Cq a W STRAIGHT CHANGE IN a z ACCESS AISLE a Cn CD LU co w W Z a DIRECTION z PARALLEL CURB RAMPS FIGURE 11B-406.3.2 N OF ACCESINTERNATSIBILITY TY 36NAL 60E mi =) X o UJ Z o A INCHES BY 36 INCHES MIN Z a 7L - VAN CAR �- ti W O w °�' U) z FIGURE 11 B-405.9.2 I AT LEAST AS WIDE � Z a CURB OR BARRIER EDGE PROTECTION Z , AS CURB RAMP J coa o co NO NO `� NO W Z (C) z PARKING PARKING PARKING < W TOP LANDING o J °�—` o m co FLARED SIDES U) Z 1:10 MAX SLOPE = J 144" MIN 108" MIN 60" MIN ~ a 60" MIN WHITE LETTERING, SLOPE SLOPE 12 INCHES MIN. HEIGHT FIGURE 11B-405.7 RAMP LANDINGS (A) (A) (A) FIGURE 11B-406.5.3 FIGURE 11B-406.2.2 PERPENDICULAR PARKING PERPENDICULAR PARKING PERPENDICULAR PARKING LANDINGS AT TOP OF CURB RAMPS SIDES OF CURB RAMPS FIGURE 1113-502.2 FIGURE 11B-503.3 FIGURE 1113-502.3 RADIUS 1/2" MAX 1 1/2" MIN � 4-6 1/4" PERIMETER i 12" MIN 12" PLUS TREAD DEPTH MIN 3�� MPX 12" (A) (B) z 12" MI 12, _ 'MIN _ Z N--------- RADIUS OF TREAD EDGE ANGLED RISER =---------- °� \�` 21 /4" MAX ❑ (TYPICAL FOR ALL PROFILES) � N ❑ X EE 1 1 /4" MAX M - 11/4" MAX 00 °° C M�"� Z---------- (A) (B) omimmo* — NOTE: X= TREAD DEPTH (C) (D) (A) (B) (C) PROJECTING OBJECTS RECESSED OBJECTS CURVED NOSING BEVELED NOSING STAIRS RAMPS WALKING SURFACES FIGURE 11B-505.7.2 FIGURE 11B-504.5 FIGURE 1113-505.4 FIGURE 11B-609.3 FIGURE 1113-505.6 FIGURE 1113-505.5 HANDRAIL NON -CIRCULAR CROSS FIGURE 1113-505.10.1 FIGURE 11B-505.10.2 FIGURE 1113-505.10.3 STAIR NOSINGS HANDRAIL HEIGHTS SPACING OF GRAB BARS HORIZONTAL PROJECTIONS BELOW GRIPPING SURFACE HANDRAIL CLEARANCE SECTION TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS TOP HANDRAIL EXTENSION AT STAIRS BOTTOM HANDRAIL EXTENSION AT STAIRS 0 T N W ~ Z � F- U)O z LU w Cnz W Qcn D O �Q 59" MIN @ FLOOR 59" MIN @ FLOOR MOUNTED WATER CLOSET W 59" MIN @ FLOOR 59" MIN @ FLOOR MOUNTED WATER CLOSET �^^ CaC cn Of MOUNTED WATER CLOSET MOUNTED WATER CLOSET 56" MIN @ WALL V) G =) Q 56" MIN @ WALL 56" MIN @ WALL 56" MIN @ WALL MOUNTED WATER CLOSET Z W MOUNTED WATER CLOSET MOUNTED WATER CLOSET MOUNTED WATER CLOSET 36„ 56" MIN WHEN DOOR TOILET PAPER DISPENSER �/� Z Q J SWINGS IN C� C� SANITARY NAPKIN 13 1/2"MIN 131/2" MIN V) Q Q 36"MIN 54"MIN Q Z CLEARANCE DISPOSAL UNIT CLEARANCE CLEARANCE W z DOOR PERMITTED TO CLEARANCE FA � � SWING OVER HATCHED z z DOOR PERMITTED TO CLEARANCE 24" MIN 12" MIN 12" MAX-- 42" MIN o W ~ W SWING OVER HATCHED cD W PORTION OF MANEUVERING co o o PORTION OF MANEUVERING z w Z z SPACE c0rD 60" MIN @ SIDE � � / z � � w � � � U. SPACE o DOOR PERMITTED TO SWING - a ) t Of OR MANEUVERING SP E 17" 18" 17" 19" r OVER HATCHED PORTION TRANSFER 24 MIN o o 0 J OF MANEUVERING SPACE r 48"MIN 48"MIN / SIDE 00 60 MIN WHEELCHAIRAACCESSIBLE AMBULATORY ACCESSIBLE 48"MIN co MANEUVERING MANEUVERING t h , M MANEUVERING SPACE WATER CLOSETS WATER CLOSETS (A) SPACE (B) SPACE (A) (B) 7"-9" (A) WALL (B) OUT -SWINGING IN -SWINGING OUT -SWINGING IN -SWINGING HUNG TYPE STALL TYPE DOOR DOOR DOOR DOOR FIGURE 11B-604.5.2 FIGURE 11B-604.5.1 FIGURE 11B-604.7.1 FIGURE 11B-604.7.2 FIGURE 1113-605.2 REAR WALL GRAB BAR AT SIDE WALL GRAB BAR AT WATER DISPENSER OUTLET LOCATION DISPOSAL UNIT LOCATION HEIGHT AND DEPTH OF URINALS FIGURE 11B-608.8.1.1.3 FIGURE 11B-608.8.1.1.2 FIGURE 11B-604.2 FIGURE 1113-604.3.1 WATER CLOSETS CLOSETS MANEUVERING SPACE WITH END -OPENING DOOR MANEUVERING SPACE WITH SIDE -OPENING DOOR WATER CLOSET LOCATION SIZE OF CLEARANCE AT WATER CLOSETS 27" MAX Y a 19"MIN 15" MAX w DRINKING FOUNTAIN NOTES:��� 1. 11 B-602.3 Operable parts - Operable parts shall comply with Section 11 B-309. The flow of water shall be activated by a manually operated system that is front mounted or side mounted and located within 6 inches SIDWALL BACK (152 mm) of the front edge of the fountain or an automatic electronically controlled device. WALL 00 2. 11 B-602.4 Spout height - Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground. 3. 11 B-602.5 Spout location - The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers. 27" MAX 4. 11 B-602.6 Water flow - The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall (A) (B) be located 5 inches (127 mm) maximum from the front of the unit. The angle of the water stream shall be 15" 16" 19"MIN BACK WALL 6" MAX 6" MAX 6" MAX ELEVATION ELEVATION measured horizontally relative to the front face of the unit. Where spouts are located less than 3 inches (76 BACK O � BACK WALL - BACK WALL mm) of the front of the unit, the angle of the water stream shall be 30 degrees maximum. Where spouts are WALL = \ - BACK WALL - LL LU located between 3 inches (76 mm) and 5 inches (127 mm) maximum from the front of the unit, the angle of j A `0 SIDE SIDE SIDE a the water stream shall be 15 degrees maximum. � SIDE WALL z o lJJ SIDE � �, \ WALL IDE WALL BACK WALL D 5. 11B-602.7 Drinking fountains for standing persons - Spout outlets of drinking fountains for standing _ WALL SIDE SIDE \ WALL persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor SEAT � SIDE WALL WALL o WALL U) SIDE LLJ or ground. WALLCl) WALL SIDE WALL cc 6. 11 B-602.8 Depth - Wall- and post -mounted cantilevered drinking fountains shall be 18 inches (457 mm) \J L IN NFRONT minimum and 19 inches (483 mm) maximum in depth. COMPARTMENT COMPARTMENT WALL 36" MIN z (A) (B) WALL FRONT RESERVED WITH SEAT 7. 11 B-602.9 Pedestrian protection - All drinking fountains shall either be located completely within ENTRY ENTRY (A) (B) 60" MIN WALL M I alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into 2 1/2" MAX RESERVED WITH SEAT pedestrian ways. The protected area within which a drinking fountain is located shall be 32 inches (813 mm) FRONT wide minimum and 18 inches (457 mm) deep minimum, and shall comply with Section 11B-305.7. (A) (B) NOTE: INSIDE FINISHED DIMENSIONS MEASURED AT THE 60" MIN WALL When used, wing walls or barriers shall project horizontally at least as far as the drinking fountain and to RECTANGULAR L-SHAPED CENTER POINT OF OPPOSING SIDES (C) (D) within 6 inches (152 mm) vertically from the floor or ground surface. NOTE: INSIDE FINISHED DIMENSIONS MEASURED AT THE RESERVED PLAN CENTER POINT OF OPPOSING SIDES NOTE: 1. BUBBLER ORIFICE TO BE WITHIN 6" OF THE FRONT OF THE DRINKING FOUNTAIN WITH THE WATER STREAM PARALLEL TO THE FRONT EDGE 4" MIN. HIGH FIGURE 1113-610.3.1 FIGURE 11B-610.3 FIGURE 11B-608.5.2 FIGURE 11B-608.2.3 FIGURE 11B-608.3.3 FIGURE 11B-608.2.2 FIGURE 11B-608.3.2 FIGURE 11B-608.5.3 RECTANGULAR SHOWER SEAT EXTEND OF SEAT STANDARD ROLL -IN TYPE ALTERNATE ROLL -IN TYPE GRAB BARS FOR ALTERNATE ROLL -IN STANDARD ROLL -IN TYPE GRAB BAR FOR STANDARD ROLL -IN TYPE SHOWER ALTERNATE ROLL -IN TYPE w 2. CONTROL LEVER TO BE LOCATED WITHIN 6" OF THE FRONT AND ACTIVATED BY A FORCE NOT SHOWER COMPARTMENT CONTROL LOCATION SHOWER COMPARTMENT SIZE AND CLEARANCE TYPE SHOWERS SHOWER COMPARTMENT SIZE AND CLEARANCE SHOWER COMPARTMENT CONTROL LOCATION EXCEEDING 5 POUNDS U) Q J_ Q Q � W z � w LOW WALL F ih ih OR L SHAPE N U RAILING U J W 48" DRINKING FOUNTAIN U SE w o cG m z;, , m 5" MAX 1'4' DATE: xxxx M o MIN. 8"MIN 6" MAX JOB NO.: SEA-21-011 KNEE CLR. 17" TOE CLR. MIN. N 7 O OKEYNOTES I a Lu U) Lu a Lu Lu O GENERAL NOTES 1. GENERAL CONTRACTOR TO PROVIDE TEMPORARY FENCING AS NEEDED TO KEEP SITE SECURED UNTIL ENTIRE PROJECT IS COMPLETED. 2. WALKWAYS AND SIDEWALKS ALONG THE ACCESSIBLE PATH OF TRAVEL SHALL BE CONTINUOUSLY ACCESSIBLE. THEY SHALL HAVE A MAXIMUM 1/2" CHANGES IN ELEVATION, OR PROVIDE CURB RAMPS COMPLYING WITH CBC 11B-406. THEY SHALL BE A MINIMUM OF 48" IN WIDTH. WHERE CHANGES IN ELEVATION EXCEED 5% WALKWAYS AND SIDEWALKS SHALL HAVE PEDESTRIAN RAMPS COMPLYING WITH CBC 11 B-405, CBC 11 B-206.2.2, 11 B-303.1, 11 B-403.5, 11 B-405 AND 11 B-406. PLAN LEGEND NOT IN CONTRACT AREA. yffA ACCESSIBLE ASILE. PROPERTY LINE. DASHED LINE INDICATES EXISTING ACCESSIBLE PATH OF TRAVEL (5% SLOPE MAX, IN THE DIRECTION OF TRAVEL 2% MAX CROSS SIDE SLOPE) TRUNCATED DOME. LANDSCAPE AREA. CONCRETE PAVING. AREA TABULATION SITE AREA XX,XXX S.F. BUILDING FLOOR AREA 55,775 S.F. TENANT FLOOR AREA 27, 850 S.F. SITE COVERAGE XX% FAR X.XX LANDSCAPE X,XXX S.F. (XX%) PARKING ANALYSIS EXISTING PARKING COUNT- EXISTING PARKING TO REMAIN m z z w w w > 0 LL a U) � z C) z Q z X W Lu ~ J� O r N W ~ z �O cl)� cnz >-_ acl) a l LLI cn �a w� a J = a I W W W 0 LLI LL 0 r 00 M M CO Y cz Q w cz IY O Lu a o IL 0 W U) > w U) v 1 w ryC Q J J c/� Q z w w > J 0 U I z a J a W H DATE: xxxx JOB NO.: SEA-21-011 SITE PLAN SCALE 1/32" = l'-0" 0 OKEYNOTES 1.4 REMOVE EXISTING PARTITION WALLS & ASSOCIATED ELECTRICAL, DATAPHONE & JBOXES- REMOVE ALL WIRING BACK TO THE SUB PANELS 1.6 REMOVE EXISTING DOOR AND FRAMES. REUSE / OR RETURN TO OWNER FOR FUTURE USE. 1.9 REMOVE EXISTING FLOORING IN AREAS SHOWN. SCRAPE ALL FLOORS CLEAN OF ASLL ADHESIVE, PAD, ETC TO SMOOTH FINISH AND BROOM CLEAN. w Cc D H U W 2 U 2 Q N a W H U) Z_ H GENERAL NOTES GENERAL CONTRACTOR TO VERIFY STRUCTURAL ELEMENTS PRIOR TO DEMOLISH WORK. 2. GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF ALL EXISTING MOLD THAT MAY BE ENCOUNTERED DURING CONSTRUCTION USING BLEACH OR APPROVED EQUAL. AFTER BEING CLEANED, AFFECTED AREAS SHALL BE ALLOWED TO DRY THOROUGHLY BEFORE COVERING. APPLY 5 6 7 9 COMPONENTS THROUGH OUT APPROVED EQUAL TO ALL EXPOSED WOODEN STRUCTURE 3. THE CONTRACTORS SHALL FULLY ACQUAINT THEMSELVES WITH THE EXISTING CONDITIONS. THEY SHALL HAVE VISITED AND INSPECTED THE JOB SITE, AND BE FULLY INFORMED AS TO THE NATURE OF THE WORK. STARTING OF DEMOLITION AND REMOVAL OPERATIONS WILL BE CONSTRUED AS EVIDENCE THAT THE CONTRACTOR HAS COMPLIED WITH THESE REQUIREMENTS AND LATER CLAIMS FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN WILL NOT BE RECOGNIZED. 4. PARTICULAR ATTENTION SHALL BE GIVEN TO THE PROTECTION OF EXISTING STRUCTURE AND FINISHED SO AS TO PREVENT ANY DAMAGE OF EXISTING FINISHES NOT DESIGNATED FOR DEMOLITION. PROVIDE ALL NECESSARY TEMPORARY CONSTRUCTION AND DUST PRROF PROTECTION. PROTECTION SHALL BE IN COMPLIANCE WITH BUILDING STANDARDS. TYPE AND LOCATION OF PROTECTION SHALL BE REVIEWED WITH OWNER OR BLDG.MNGT. PRIOR TO COMMENCING WORK. 5. LEAVE SPRINKLERS INTACT AS -IS (ONLY DURING DEMOLITION). ALL FIRE LIFE SAFETY EQUIPMENT SHALL BE LEFT IN PLACE. IF A STRUCTURAL HOLDING DEVISED IS REMOVED, THE CONTRACTOR SHALL SUPPORT THE FIRE LIFE SAFETY DEVICE IN A MANNER THAT DOES NOT IMPAIR ITS FUNCTION IN ANYWAY. cq 0 w a N Lu O N U p U Lo �co Inv a- w w U N z z ~ !a uj of z� aZ IL I� W F c_ co Z_ z 0 W � Fw i W w� EL EL } d m W d = W ~U wx <w ¢Y� U z0 O� Uw EL F U0 w d> cn z o¢ z= ¢O 10 E ZW 3:7:) ¢W �m of w0 U)Z W J 2 J F 2 6. THERMOSTATS AND PNEUMATIC LINES SHALL BE REMOVED GENTLY AND COILED BACK TO THE 0 DEVICE THEY CONTROL AND LEFT IN PLACE. r N ----------------------------------------------- -------------------------------------------------- 7. UPON REMOVAL OF THE EXISTING CEILING, THE EXISTING MECHANICAL SYSTEM WILL BE EVALUATED LV — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — FOR POSSIBILITY OF RE -USE. IF THE EXISTING MECHANICAL SYSTEMS ARE TO BE REUSED, EXISTING MAIN DUCT, VAV BOXES, PNEUMATIC CONTROL TUBING ETC. SHALL REMAIN AND SHALL BE /1 Z ) 1.4 PROTECTED TO AVOID DAMAGE TO EXISTING HVAC EQUIPMENT. V p O 1.4 8. CONTRACTOR TO VERIFY THAT ALL EXISTING LIGHT FIXTURES NOT BEING REUSED SHALL BE z Z ., R V RETURNED TO BUILDING STOCK. (n W W Z --------------�, /���--- 9. ALL FIRE LIFE SAFETY EQUIPMENT SHALL BE LEFT IN PLACE. IF A STRUCTURAL HOLDING DEVISED IS REMOVED,CONTRACTORSUPPORT THE FIRE LIFE SAFETY DEVICE IN A MANNER EMOV D, THE NT C G G Q / \ LV 1.4 RACTOITS FUNCTION IN ANY E NOT D O Q 10. REMOVED ALL DATA/TELE CABLING IN CEILING BACK TO ORIGINAL DEMARK. UNLESS OTHERWISE 1.61 I I 1 6 INSTRUCTED). CONTRACTOR TO VERIFY WITH THE TENANTS CABLING VENDOR. W _ I I 11. ABANDONED PLUMBING LINES AND DRAINS TO BE REMOVED BACK TO POINT OF ORIGINATION AS a U) cn Q REQUIRED FOR FUTURE TENANTS BUILD -OUT. z W 12. INTENT OF THE DRAWING IS TO SHOW EXISTING BUILDING CONDITIONS DEVELOPED FROM AVAILABLE z DOCUMENTS. CONTRACTOR SHALL MAKE A DETAILED SURVEY OF EXISTING CONDITIONS �/= J V ) Q PERTAINING TO THE WORK BEFORE COMMENCING DEMOLITION. THE CONTRACTOR SHALL REPORT Q OPEN OFFICE CONFERENCE CONFERENCE DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL FIELD CONDITIONS TO THE ARCHITECT. Q z W X Lu >. LV 13. MAINTAIN FULLY CHARGED FIRE EXTINGUISHER READILY AVAILABLE DURING ALL DEMOLITION W W OPERATIONS. 1.4 1.4, +� uj 14. WHERE CONSTRUCTION TO BE REMOVED INTERSECTS CONSTRUCTION TO REMAIN, WORK SHALL LL INCLUDE ALL ATTACHMENT DEVICES (SHOT PINS, ANCHORS, LAG BOLTS, NAILS, NAILERS, SHIMS, 0 ETC.). � 15. EXISTING ELECTRICAL OUTLETS, RACEWAY AND WIRING ETC. WILL BE REMOVED, UNLESS M C �O II OTHERWISE NOTED co PLAN LEGEND NOT IN CONTRACT AREA. EXISTING WALL TO REMAIN. EXISTING WALL TO BE REMOVED. EXISTING GLAZING & FRAME TO BE REMOVED. EXISTING DOOR TO REMAIN. EXISTING DOOR TO BE REMOVED. Y a W 0 IL Lu o W U) > U) w cc cry z W DATE: xxxx JOB NO.: SEA-21-011 z Q J a. z 0 F_ J 0 2 Lu 0 cc 0 0 J LL FLOOR DEMOLITION PLAN SCALE 3/16" = V-0" a Al ol OKEYNOTESYj o� z 1.12 REMOVE EXISTING CEILING TILES, GRIDS & LIGHTING z Ato zF t F 0 LL W N w >2 J F W ~ W W w d O Cc rn O 2 H2 CDdm W O N W d 2 = 0 F W _ In w CC? X rn aW w z O a F- u) O I--z ¢ = u) z U w z ~ V W F A H m d } U) Q N ¢O pj U) L z W W z j Q �m F w0 A W J = J F 2 GENERAL NOTES 1. DEMOLISH AREA OF HARDLIT CEILING ABOVE AREA OF NEW CONSTRUCTION AS REQUIRED FOR REWORKING OF FIRE LIFE SAFETY. 5 6 7 8 9 Og0 --------------------- O T N -------------------------------------------- W ---- U ~ Z II I F-- F— Cf) F- z z 0 PLAN LEGEND � a - - 1.12i UJ cf) Q Z r--- r---- r-- NOT IN CONTRACT AREA. O Q I I I I I I I I I I I I I I I III II IL II I�__J I�__J EXISTING WALL TO REMAIN. W ., L--- --- --- --- --- L--- L--- L--- L--- --- --- --- --- I--- �/� a - - - - - - - - EXISTING WALL TO BE REMOVED. c J G = Q I z F- W� LIMIT OF CEILING DEMOLITION ' ^ Z = J I .12 .12Lu EXISTING GYP. BD. CEILING TO REMAIN. X W uJ --- --- --- --- W W = Lu ------ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - - - - EXISTING GYP. BD. CEILING TO BE REMOVED. �L I I I O I I T I I L----J L----J L----J L----J L----J L- G' I EXISTING SUSPENDED CEILING TO REMAIN. co I 031 I I I I EXISTING SUSPENDED CEILING TO BE REMOVED. r� r----� EXISTING 2' X 4' RECESSED LIGHT FIXTURE TO REMAIN. I I - L----J EXISTING 2' X 4' RECESSED LIGHT FIXTURE TO BE REMOVED. I I EXISTING 2' X 2' RECESSED LIGHT FIXTURE TO REMAIN. J II I I 1.12i EXISTING 2' X 2' RECESSED LIGHT FIXTURE TO BE REMOVED. _I I N . 1. EXISTING RECESSED DOWN LIGHT TO REMAIN. I I I I I I EXISTING RECESSED DOWN LIGHT TO BE REMOVED. I I ®1 EXISTING CEILING MOUNTED EXIT SIGN TO REMAIN. ILU EXISTING CEILING MOUNTED EXIT SIGN TO BE REMOVED. IP I I /D \\ O V) V) Lu J Q Q 0 Z w W � J z — C.)U 0 W C� W J Z IL Q W J DATE: xxxx JOB NO.: SEA-21-011 O z L.IJ Al 02 CEILING DEMOLITION PLAN 3/SCALE o A Y a w w O LL o W w w N N a N O OKEYNOTES L N. I. C. U m PLAN LEGEND z z Lu pp 5w � 6 NOT IN CONTRACT AREA. ` LLB 0 EXISTING WALL TO REMAIN. a NEW WALL, SEE WALL CONSTRUCTION LEGEND. �� U) z — MAXIMUM PATH OF TRAVEL. Z ® EXIT LIGHT W / 90 MIN. BATTERY BACK UP, SHADED AREA INDICATES FACE U) OF LETTERING, DIRECTIONAL ARROW AS REQUIRED. SEE ELECTRICAL Q Z DRAWINGS. x W FIRE EXTINGUISHER. SEE ui OCCUPANCY LOAD ANALYSIS OCC. TYPE NUMBER NAME AREA 100 CONF. ROOM 183 SF 101 LOBBY 110 SF 102 BREAK ROOM 289 SF 103 VESTIBULE 106 SF 104 SHOP -1 138 SF 105 ELEC/MECH RM 112 SF 106 ENGINEERING LAB 1242 SF 106B RFI CHAMBER 99 SF 107 OFFICE 101 SF 108 IDF 88 SF 110 PH ROOM 55 SF 111 PH ROOM 55 SF 112 PH ROOM 55 SF 113 CONF. ROOM 351 SF 114 CONF. ROOM 189 SF 115 COLLABORATIVE 183 SF 116 OPEN OFFICE 3109 SF 117 CORRIDOR 169 SF 118 COPY/PRINT 119 SF OCCUPANT LOAD ANALYSIS LOAD FACTOR I OCCUPANT LOAD I EXIT WIDTH REQUIRED OCCUPANCY: X SPRINKLERED: X PROJECT AREA: +/ X,XXX SF OCC LOAD : FIRST FLOOR: ± XX,XXX SF B OFFICE (1:100) _ ± X,XXX SQ FT X OCC WAITING (1:15) = ± X,XXX SQ FT X OCC STORAGE (1:300) = ± X,XXX SQ FT X OCC PER TABLE 1006.2.1: TWO EXIT REQUIRED W/ MAX COMMON PATH OF TRAVEL: 100' PER TABLE 1017.2: MAX EXIT ACCESS TRAVEL DISTANCE: 300' PER TABLE 1020.1 EXCEPTION 4 FIRE RESISTANCE FIRE RATING IS NOT REQUIRED FOR CORRIDORS IN GROUP B OCCUPANCY. PATH OF TRAVEL PATH NAME DISTANCE TRAVELED 0'-01, J� 0 71, LLJ ~ Z �O cl)� cnz �_ Q Q l LLI cn Q Lu ?� Q J = Q LLI LJ.I LLJ 0 LLI LL. 0 r 00 M M Y Q W O Lu Q o LL 0 LLI (n > w Cn J Q z L� Q Lu Q a z c� w 0 J o U z Q Z � Z a � J W M DATE: xxxx JOB NO.: SEA-21-011 EXISTING OCCUPANCY ANALYSIS PLAN 3/1CALA 1'-0" A2mO OKEYNOTES 2.1 CONTRACTOR TO RAISE EXISTING DEMISING WALL TO STRUCTURE, MATCH WALL TYPE INDICATED. GENERAL NOTES W Cc D H U W 2 U 2 Q N a W H Z_ H 04 0 N Lu Lu Q N O 0 N U p U � < c6 N a w w N N z z ~ V uj IL o� z� aZ IL I� W F U_ U)F Z_ Z 0 W } 2 F W W W d EL } d m W d ~ = W wxU �w ¢Y U z0 O0 Uw LL F U0 w d> cn z o¢ z= ¢O W L O� ZW �7:) ¢W �m of w0 U)Z W J 2 J F 2 �'-01, 11 11 1 �I � PLAN LEGEND 8'-0" 70'-0" 10'-01, 8'-81, 5'-0"� 'I UP r1l CV NOT IN CONTRACT AREA. W Z 3 21 PH ROOM - CORRIDOR - /'1 v � 1 AO ELECIMECH q� RFI 3 IDF 3 112 w EXISTING WALL TO REMAIN. 7 z Z R CHAMBER 108 <1 t3 112 cn V RM �83 8 NEW WALL, SEE WALL CONSTRUCTION LEGEND. w SHOP-1 104 105 108 O ALIGN NEW 1-HR RATED WALL, SEE WALL SCHEDULE. C G CW c W Q � ENGINEERING COPY/ RINT PH ROOM 1B EXISTING GLAZING & FRAME TO REMAIN. D > 0 cn Q 2.1 4 A8.3 LAB LAB 11 111 1 B NEW GLAZING & FRAME, SEE WINDOW SCHEDULE ON SHEET A8.1 t W 3 O 1 B 111 EXISTING DOOR TO REMAIN. r � ) VJ a ., O106B 3 3 104 105 O O = - o OFFICE 1 O7 3 PH ROOM NEW SINGLE DOOR, SEE DOOR SCHEDULE ON SHEET A8.1 Q 1 110 Z A8.3 - 0 w Q VESTIBULE 103A - i g A8.3 110 FIRE EXTINGUISHER. SEE X LZ LLB W 1 30 B 00 106AAC1 91 ROOM CONF.O HI-LO DRINKING FOUNTAIN. SEE � � W o w � 3 113 U. 3 z 0 v J Q 113 NOTES: T co G' ----- ----- 10 1. USE MOISTURE & MOLD RESISTANT GYP. BD. ON WET WALLS (FULL HEIGHT) co FLOOR PLAN SCALE a WALL TYPE LEGEND (SEE "WALL CONSTRUCTION LEGEND" FOR "NUMBER" (X) DESIGNATION OF WALL TAG) LINE OF CEILING FINISH O <xC> <0> NOTE: 1. INTERIOR PARTITIONS THAT EXCEED 12'-0" A.F.F., PROVIDE BRIDGING AT 4'-0" O.C. MAX. 2. FOR TYPICAL STUD PARTITION FRAMING - SEE A / A1.0 WALL CONSTRUCTION LEGEND 1A 1 HOUR RATED WALL - 5/8" TYPE GYP. BD. (BOTH SIDES) OVER 3-5/8 METAL STUD FRAMING TO UNDERSIDE OF STRUCTURE W/ SOUND INSULATION. PROVIDE FIRE CAULKING AT TOP AND BOTTOM. 1 B 5/8" GYP. BD. BOTH SIDES OVER 3-5/8" METAL STUD FRAMING TO 6 ABOVE CEILING AT 24 O.0 WITH SOUND INSULATION 2A 5/8" GYP. BD. (BOTH SIDES) OVER 3-5/8" METAL STUD FRAMING TO UNDERSIDE OF STRUCTURE W/ SOUND INSULATION & HOMASOTE ON SHEET ROCK 3� 5/8" GYP. BD. (BOTH SIDES) OVER 3-5/8" METAL STUD FRAMING TO UNDERSIDE OF STRUCTURE W/ SOUND INSULATION. KEY PLAN U) Y a W cr cc O ILL Lu o LLI U) > w U) cc cn cn W DC 0 Q z W U z Q J a. cc 0 0 J LL DATE: xxxx JOB NO.: SEA-21-011 3/16" = 1'-0" 10'-5" N. I. C. 7, - 8" 5'-0° T-8" POWER AND DATA PLAN SCALE A 3/16"=1'-0' OKEYNOTES GENERAL NOTES --- EXISTING WALL MOUNTED FIRE EXTINGUISHER TO BE REPLACED WITH NEW SEMI RECESSED FIRE EXTINGUISHER CABINET. CI) PLAN LEGEND z w NOT IN CONTRACT AREA. Z) LIGHT SWITCH 9 POWER OUTLET V �/) QUAD POWER OUTLET z T PHONE OUTLET p DATA OUTLET U) Y PHONE/DATA OUTLET Q $ NURSE CALL W/ BLUE PULL STRING - SEE DETAIL X �v RECESSED FLOOR POWER/ PHONE/ DATA w ACCESS CONTROL DOOR. T THERMOSTAT - VERIFY LOCATION W/ ARCHITECT PRIOR TO INSTALLATION - REFER TO MECHANICAL DRAWINGS NURSE CALL SIGNAL LIGHT AIP AIPHONE REMOTE DOOR OPERATOR FW FIRE ALARM ANNUNCIATOR PANEL ELECTRIC STRIKE WN NURSE CALL ALARM PANEL FIRE EXTINGUISHER. SEE 4'-0" TELEPHONE BACK BOARD E.P. ELECTRICAL PANEL - REFER TO ELECTRICAL DRAWINGS. KEY PLAN uj 0- o� zU) a Z 0- U� z_ t Q 0 LLW N w >2 J F W Q W Lu d O 2 N o dm O N U 2 p 2 CDF W cr CC?W x �w aW 0 w ~ cn z O O U) ¢� Z U w ~ V W U F O rn a) d} IL Z C,Q N ¢O pj U) L W ZW Z �j Q �m F w0 wz W J F 2 0 T N W ~ z �0 H Cf)H cnz w M >-_ acn > �a 0 Ca cn >- c � Q Q Q W W F- � LU o W W LL 0 T co M M U) Y a w cr cc 0 ILL Lu o W D U) > U) w cc ) � v J Lu re z Q Q J a a � F- z LU o U o z Q W 0 DATE: xxxx JOB NO.: SEA-21-011 co N 46 FINISH LEGEND SHEET VINYL 6yvQi STYLE: COLOR: INSTALL: CONTACT:- (E)-@-.com (P) - LUXURY VINYL PLANK: LV-1 STYLE: COLOR: INSTALL: CONTACT:- (E)-@-.com (P) - CARPET: C-1 CARPET TILE STYLE: COLOR: INSTALL: CONTACT:- (E)-@-.com (P) - BASE: B-1 B-2 STYLE: COLOR: STAIR NOSING *]a STYLE: - COLOR: - WALL PROTECTION: FRP-1 STYLE: - COLOR: - CLASS: - TEXTURE:- 48" A.F.F. U.N.O. ACRYLIC PANEL AD-1 - STYLE: - COLOR: - 48"xl8"xl/4" PAINT: P-1 P-2 P-3 P-4 P-5 P-6 P-7 P-8 PLASTIC LAMINATES ZIG PATTERN:- NUMBER: - 0 o UPPER & LOWER CABINETS PL-2 PATTERN:- --- NUMBER:- UPPER & LOWER CABINETS - RECEPTION AREA \ PL-3 O BREAK [� PATTERN: - ROOM NUMBER: - 102 CONF. REVEALS - RECEPTION ROOM PL-4 114 PATTERN:- NUMBER- - WITH PVC EDGE OPEN COUNTERTOPS OFFICE DOORS 116 WV-1 FINISH: - ---------- SOLID SURFACE: -- - - - - - - -- 0 SS-1 COLOR: - FINISH: - ACOUSTIC CEILING SYSTEMS: ACT-1 - (AT 9'-6" AFF-U.O.N.) LOBBY COLLABORATIVE SIZE: - 101 115 N. I. C.GRID:EXISTING STYLE: - TO REMAIN. COLOR: WH ITE GYPSUM BOARD CEILING SYSTEMS: PAINT P-1, U.N.O. - SEE REFLECTED CEILING PLAN 0KEYNOTES GENERAL NOTES FLOOR FINISH NOTES 1. FLOOR SURFACE TO BE CLEAN, SOUND AND MOISTURE FREE PRIOR TO INSTALLING ALL FLOOR FINISHES. 2. ALL DIRT, DUST, LAITANCE, CURING COMPOUNDS, GLUE AND DELAMINATING MATERIALS MUST BE REMOVED PRIOR TO ANY MATERIAL APPLICATIONS. 3. USE SCHLUTER COVE TRIM AT TILE FLOOR AND WALL TRANSITIONS. 4. USE WALL CORNER GUARDS AT ALL CORNERS UNLESS OTHERWISE NOTED 5. ALL PAINTED INTERIOR DOOR AND WINDOW FRAMES TO MATCH ADJACENT WALL, U.N.O. 6. ALL OFFICES SHALL RECEIVE THE FOLLOWING FINISHES: P-1, P-5, C-1, B-1, P-2 (ACCENT WALL) 7. ALL ROOMS SHALL RECEIVE THE FOLLOWING FINISHES: P-1, P-5, SV-1, B-1, P-3 (ACCENT WALL) WALL FINISH NOTES: 1. ROOMS RECEIVING FRP TO 48" AFF SHALL RECEIVE THE PAINT FINISH DESIGNATED IN EACH. 2. ROOMS, AND/OR AS NOTED OTHERWISE WITH A PAINT FINISH TAG, ABOVE THE FRP TO CEILING. 3. WET BOARD TO GO 4'-0" MIN. VERTICALLY PASS WATER SOURCE. MILLWORK NOTES: 1. ALL MILLWORK SHALL BE PROVIDED AND INSTALLED BY GENERAL CONTRACTOR. 2. GENERAL CONTRACTOR SHALL COORDINATE MILLWORK FABRICATION WITH A QUALIFIED MILLWORK FABRICATOR. 3. GROMMETS: PROVIDE GROMMETS w/ COVERS AS REQUIRED AT ALL KNEE SPACES. 4. LOCKS: PROVIDE LOCKS AT ALL CABINETS & DRAWERS IN THE LAB/WORK AREA, OFFICES. NOTE: INTERIOR WALL, CEILING AND FLOOR FINISHES SHALL COMPLY WITH THE SPECIFICATIONS DETAILED IN BUILDING CODE SECTIONS 803AND TABLE 803.11. DECORATIVE MATERIAL AND TRIM SHALL MEET THE FLAME PROPAGATION PERFORMANCE CRITERIA OF NFPA 701 FOR OCCUPANCIES SPECIFIED IN BUILDING CODE 806 EXCEPT FIXED OR MOVEABLE WALLS, PARTITIONS, PANELING, WALL PADS AND CRASH PADS APPLIED STRUCTURALLY OR FOR DECORATION, ACOUSTICAL CORRECTION, SURFACE INSULATION OR OTHER PURPOSES WHICH COVER MORE THAN 105 OF THE WALL OR CEILING SHALL COMPLY WITH BUILDING CODE 803. PLAN LEGEND ALL WALLS AND SOFFITS SHALL BE PAINTED P-1 UNLESS DESIGNATED OTHERWISE BY A PAINT TAG ON THIS PLAN. ROOM NAME WALL FINISH 101 WALL BASE P-5 B-1 SV-1 ACT-1 FLOOR FINISH CEILING FINISH NOT IN CONTRACT AREA. FLOOR TRANSITION WP-01 48" A.F.F. - U.O.N. WP-02 FULL HEIGHT - U.O.N. ACCENT WALL FINISH MILLWORK FINISH ROOM NUMBER I ROOM NAME I WALL FINISH I FLOOR FINISH I BASE FINISH I CEILING FINISH 104 SHOP -1 105 ELEC/MECH RM 102 BREAK ROOM 113 CONF. ROOM 114 CONF. ROOM 112 PH ROOM 111 PH ROOM 110 PH ROOM 107 OFFICE 108 IDF 115 COLLABORATIVE 116 OPEN OFFICE 106 ENGINEERING LAB 103 VESTIBULE 100 CONF. ROOM 101 LOBBY 117 CORRIDOR 118 COPY/PRINT 106B RFI CHAMBER FINISH PLAN FINISH SCHEDULE SCALE A 3/16" = 1'-0" OUTLETS & COVER PLATES: WHITE: GENERAL DEVICE COVER PLATES GREY: DEDICATED DEVICE COVER PLATES CORNER GUARDS: CG-1 STYLE: - HEIGHT: 4' HEIGHT PROVIDE AT ALL WALL CORNERS WINDOW COVERINGS RS-1 ROLLER SHADES - (OR MATCH BUILDING STANDARD) COLOR:TBD AT ALL EXTERIOR WINDOWS WITHIN THE SCOPE OF WORK - KEY PLAN w Cc D U w 2 U 2 a U) a w U) Z_ 0 N Lu Lu a N O 0 N U p U � c6 N a w w �N z z ~ !a ui N m m z uj o0- Lu z� aZ U)- W F �F z_ z �z oW >� F W c W w� d¢ EL > EL W = W ~U LuX < W ¢Y z� z0 o� Uw L F U0 d> cn z 0¢ z= ¢0 'o LL �o z� Q W �m o� w0 U)z W J 2 J F 0 T N W U)~ Z F— � O z cn W LLJ z W Q �Q 0 Ir �^ VJ Ca Lu cn >_ z G H =) a� Q V J Q = Q W LuX � Q LuwW � LL 0 T co M W Y a w 0 LL Lu 0 a o Lu U) > w U) cc V) V) Lu oC 0 Q z Lu U z Q J a Z z LL DATE: xxxx JOB NO.: SEA-21-011 A401 OKEYNOTES p W zu) au) IL� L� z� N Q W Lu }2 F ~ W = N 0< F 22 O ELm N W H w U c =a F = o Fw U cc CC? w w Q a v cn cn a � N LLJ z OO y F Zz Ow � ¢� Z 3 <cn —` — WC a} M Q co ¢0 pj � LL Z W Lu z W z j Q �m F wp wz W J = J �a _ U) GENERAL NOTES 5 6 7 8 9 6 �----------------------�� PLAN LEGEND o CV NOT IN CONTRACT AREA. W IDF � Z 108 , PH ROOM NEW WALL, SEE WALL SCHEDULE. O N N E112 (n N +g 0 - N EXISTING WALL TO REMAIN. z Z - V E ECIME H w CWC Z HOP - RM N N NEW GYP. BD. CEILING. G Q 9 04 105 N N N N N N N N ORRI OR g_ p 2' _ g > o g - O PH ROOM 1�1 �� O O EXISTING GYP. BD. CEILING TO REMAIN. � O + - ENGINEERING OFFICE! 9 LAB 107 COPY/PRINT E+q� 1o„ u 19' _0 118 N a cn >- ON N N g- o o NEW SUSPENDED CEILING. z W a w N N NN N N N N N PH ROOM N N V) Z = J N N 11 CONF. Q Z 44 Ix 04 04 +goN O 113 O EXISTING SUSPENDED CEILING TO REMAIN. W W VESTIBULE 1 3 g' - 0' X � � W N ui wIn N N � � W o N� NEW 2' X 4' RECESSED LIGHT FIXTURE. SEE ELECTRICAL DRAWINGS. LL 0 �o 0 0 0 0 0 O N N NEW 2' X 4' RECESSED EMERGENCY LIGHT FIXTURE W / 90MIN. BATTERY BACKUP. GQ C --- -- -- --- - SEE ELECTRICAL DRAWINGS. `M yj O O EXISTING 2' X 4' RECESSED LIGHT FIXTURE TO REMAIN. 3'-51/2" 6'-0" IL N N O O G� ❑ it BREAK NEW 2' X 2' RECESSED LIGHT FIXTURE. SEE ELECTRICAL DRAWINGS. R00 CONF. 102 E ROM . SEE ELECTRICAL SED EMERGENCY LIGHT FIXTURE W / 90MIN. BATTERY BACKUP. g' 14 N +g' - 0" N EXISTING 2' X 2' RECESSED LIGHT FIXTURE TO REMAIN. E E E E E E E E E N N OPEN FFIC O NEW RECESSED DOWN LIGHT. SEE ELECTRICAL DRAWINGS. 116 N 9' - 0' ❑ N N O NEW RECESSED EMERGENCY DOWN LIGHT W / 90 MIN. BATTERY BACKUP. cz COLLABORATIVE N SEE ELECTRICAL DRAWINGS. E+9�'=-o N_ I_ C_ LO BY �� O EXISTING RECESSED DOWN LIGHT TO REMAIN. 11 E N +99-011 N UNDER CABINET LED LIGHTS, SEE ELECTRICAL DRAWINGS. E E E E E E N N ®I NEW CEILING MOUNTED EXIT SIGN W / 90 MIN. BATTERY BACK UP, SHADED AREA ❑ N INDICATES FACE OF LETTERING, DIRECTIONAL ARROW AS REQUIRED. SEE Ir ELECTRICAL DRAWINGS. ®� LL EXISTING CEILING MOUNTED EXIT SIGN TO REMAIN.Lu E CONF. ROOM 100]' E ' E E E E E E D KEY PLAN o y� ® 0 0 0 DATE: xxxx lul JOB NO.: SEA-21-011 c 0 0 0 LL w o 0 CEILING PLAN SCALE A A501 3/16 = 1 0 Y Q w O a o � W w cn c� w �C Q c� z w Z J Q U J a C� z J W C� M 00 0 0 0000 0 3- 0" 3- 0" 3- 0" W Cc D H U W cr 2 U Q N a W H z uj IL of ¢ zU) z CL C� OF Zto t F 0 LL W N w >2 J F W Q W LU d N O 2 o dm O N U p 2 d 2 CDF W cr cc?W x �w a LU w z0 ~ cn O O z O ¢� z U w ~ V W F U rn dO a)} U Z C,Q N ¢O pj U) L ZW W z �j Q �m F w0 U)z W J 2 J F 2 U) 0 T N w = Z F- � F- z w cn z w m >- __ w Q cn M M Z) >O Q Z F- a� U) a =Q Q z w� X >w PH ROOM SCALE 7 ELEC/MECH RM SCALE 4 w w w LL T co EQ. EQ. EQ. EQ. co CON F. ROOM#100 1 SCAL1E0 6 CON F. ROOM#113 1 SCAL1E0 3 U) Y a w cc O LL LU o LU D U) > w U) cc () V) W oC 0 cf) Q z O _V) � Q z w � w J U w cc O oC w z DATE: xxxx JOB NO.: SEA-21-011 SCALE SCALE SCALE COPY/PRINT 1/2"=1'-0" 8 CONF. ROOM#114 1/2"=1'-0" 5 BREAK ROOM#102 1/2"=1'-0" 2 A803 M M O N O 5/8" TYPE'X' GYP. BD. EACH SIDE OVER MFT^' QTI Ifl INSULAT METAL T 3-5/8" ME TRACK DOOR FI 1 1/4" THICK SOLID SURFACE DOOR MOUNTED SIGNAGE TO BE LOCATED IN THE CENTER OF THE DOOR - SEE ELEVATION BELOW WALL MOUNTED SIG MOUNTED ON LATCF DOOR - SEE ELEVAT CORRESPONDING GI 5/8" MIN. - 2" MAX. X 1/32" RAISED LETTLI-I- NOTE: CHARACTERS AND BACKGROUND OF SIGN TO BE NON - GLARE INISH. COLOR AND CONTRAST OF SIGN TO BE DISTINCTLY DIFFERENT FROM THE WALL COLOR (STANDARD COLOR SHALL BE WHITE CHARACTERS ON BLUE BACKGROUND UNLESS OTHERWISE APPROVED) DOOR SIGN WALL SIGN - 1'-0" ADA RESTROOM SIGNAGE 1SCALE 1/2"=1'-0" `� NOTE: SEE "SIGNS & CHARACTERS & BACKGROUND OF SIGNS TO BE NON -GLARE FINISH TO IDENTIFICATION" CONTRAST WITH EACH OTHER. (STANDARD COLOR TO BE WHITE ON GENERAL NOTES FOR BLUE BACKGROUNDS UNO) COLOR AND CONTRAST OF SIGN TO BE ADDITIONAL INFORMATION DISTINCTLY DIFFERENT THAN THE COLOR AND CONTRAST OF THE WALL. SANS -SERIF UPPERCAS CHARACTERS, RAISED 1/32" PER ANSI STANDARDS CORRESPONDING GRAE 2 BRAILLE PER CBC 11 B-73.3 AND 11 B-703.4 NOTE: DOTS SHALL BE 1/10" O.C. IN EACH CELL W/ 2/10" SPACE BETWEEN CELLS, MEASURED FROM THE SECOND COLUMN OF DOTS IN THE FIRST CELL TO THE FIRST COLUMN OF DOTS IN THE SECOND CELL. DOTS SHALL BE RAISED A MIN. 1/40" ABOVE BACKGROUND. DOTS SHALL BE ROUNDED OR DOMED DOOR AND WINDOW TYPES -A- -B- -C- -D- SINGLE FLUSH DOOR STOREFRONT GLASS SINGLE DOOR SINGLE LITE DOOR FLUSH DOOR WITH SIDE LITES DOOR SCHEDULE DOOR# FROM ROOM: TO ROOM: TYPE DOOR DIMENSION DOOR MATERIAL & FINISH FRAME MATERIAL & FINISH HDWE. SET Lu Lu LL W H T MATERIAL FINISH GLASS FINISH MATERIAL FINISH 100 CONF. ROOM OPEN OFFICE B 3- 0" T - 0" 1 3/4" WV-1 CLEAR H.M. MFR BLACK 01 101 LOBBY OPEN OFFICE B 3- 0" T - 0" 1 3/4" WV-1 CLEAR H.M. MFR BLACK 04 102 OPEN OFFICE BREAK ROOM C 3- 0" T - 0" 1 3/4" WV-1 CLEAR H.M. MFR BLACK 01 103A ENGINEERING LAB VESTIBULE C 3- 6" T - 0" 1 3/4" WV-1 CLEAR H.M. MFR BLACK 03 103B VESTIBULE A 3- 6" T - 0" 1 3/4" WV-1 CLEAR H.M. MFR BLACK 03 20 MIN. 104 VESTIBULE SHOP -1 C T - 0" T - 0" 1 3/4" WV-1 CLEAR H.M. MFR BLACK 01 105 VESTIBULE ELEC/MECH RM A 3- 0" T - 0" 1 3/4" WV-1 CLEAR - H.M. MFR BLACK 02 106A OPEN OFFICE ENGINEERING LAB C 3- 0" T - 0" 1 3/4" WV-1 CLEAR - H.M. MFR BLACK 03 106B RFI CHAMBER ENGINEERING LAB C 3- 0" T - 0" 1 3/4" WV-1 CLEAR - H.M. MFR BLACK 03 107 OPEN OFFICE OFFICE A 3- 0" T - 0" 1 3/4" WV-1 CLEAR - H.M. MFR BLACK 02 108 COPY/PRINT IDF A 3- 0" T - 0" 1 3/4" WV-1 CLEAR - H.M. MFR BLACK 03 110 CORRIDOR PH ROOM D T - 0" T - 0" 1 3/4" WV-1 CLEAR - H.M. MFR BLACK 01 111 CORRIDOR PH ROOM D T - 0" T - 0" 1 3/4" WV-1 CLEAR - H.M. MFR BLACK 01 112 CORRIDOR PH ROOM D T - 0" T - 0" 1 3/4" WV-1 CLEAR - H.M. MFR BLACK 01 113 CORRIDOR CONF. ROOM D 3- 0" T - 0" 1 3/4" WV-1 CLEAR - H.M. MFR BLACK 01 114 CORRIDOR CONF. ROOM D 3- 0" T - 0" 1 3/4" WV-1 CLEAR - H.M. MFR BLACK 01 U w x w COMMENTS W Cc D U W Cc U Q U) a W U) z uj of Z� aZ d W~ � �� zto t F 0 LL W 04 W J F W Q W Lu d° N O 2 o dm O N U p 2 d 2 p F W CC? W x W aW w z 0 F- v) O° z U W ~ V W F U° d> °' U) z oa N ¢O U� °o W ZW z �z a om W O U)z W J 2 J F Q U) 0 T N W ~ z I cnO z w cn z DOOR HARDWARE GROUPS (BUILDING STANDARD LATCHSET) w M >-_ W SET: 01 TOILET cn � Q SET: 02 BUILDING STANDARD LOCKSET 00 SET: 03 BUILDING STANDARD LOCKSET WITH MAGNETIC CLOSER AND CARD READER Ca W SET: 04 BUILDING STANDARD LOCKSET WITH MAGNETIC CLOSER AND CARD READER FOR FULL GLASS DOORS G = Q z NOTE: DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 34 AND 44 INCES ABOVE THE FLOOR. PER 2019 CBC 11B-404.2.7. H a� V) z z W X Lu � � Q W w LLi LL 0 T co M M DOOR FINISH LEGEND GL. GLASS ALUM. ALUMINUM FF FACTORY FINISH CLR. ANOD CLEAR ANODIZED WP-1 WOOD - PAINT (DOOR & FRAME TO MATCH BUILDING STANDARD) TACTILE EXIT SIGN SCALE 23 DOOR GENERAL NOTES 6"=T-0' 1. FIELD MEASURE, AS REQUIRED, ALL DOORS PRIOR TO FABRICATION. NOTE: SEE "SIGNS & CHARACTERS & BACKGROUND OF SIGNS TO BE NON -GLARE FINISH TO 2. PROVIDE A SIGN ON OR NEAR THE MAIN EXIT DOOR READING "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED". IDENTIFICATION" CONTRAST WITH EACH OTHER. (STANDARD COLOR TO BE WHITE ON 3. LATCHING AN LOCKING DOORS THAT ARE HAND OPERATED SHALL BE OPERABLE WITH A SINGLE EFFORT WITHOUT REQUIRING THE ABILITY TO GRASP THE GENERAL NOTES FOR BLUE BACKGROUNDS UNO) COLOR AND CONTRAST OF SIGN TO BE HARDWARE. (LEVER OR PUSH TYPE) VERIFY THE CONDITION OF EXISTING DOORS. ADDITIONAL DISTINCTLY DIFFERENT THAN THE COLOR AND CONTRAST OF THE 4. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LB FOR INTERIOR AND EXTERIOR DOORS AND 15 LB FOR FIRE DOORS. INFORMATION WALL. 5. ALL HARDWARE TO BE LEVER TYPE PER ADA AND GOVERNING CODES. 6. OPENING HARDWARE TO BE CENTERED BETWEEN 34" AND 40" A.F.F. CONTRACTOR TO VERIFY EXISTING CONDITION AND MATCH NEW. 7. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE. 8. PROVIDE WEATHER SEALS ON ALL EXTERIOR DOORS. 9. CONTRACTOR IS RESPONSIBLE TO VERIFY AND COORDINATE ALL DOOR FRAME THROAT THICKNESS. SANS -SERIF UPPERCASE 10. ALL DOOR FRAMES TO BE FACTORY FINISHED-UNO CHARACTERS, RAISED 11. ALL DOOR STOPS TO HAVE 2X6 OR 20 GA. BACKING. 1/32" PER ANSI EXIT 12. MAXIMUM UNDERCUT OF ALL DOORS NOT IN A RATED CORRIDOR SHALL NOT EXCEED 1/2" A.F.F. STANDARDS 13. SEE DETAIL FOR DOOR CLEARANCE REQUIREMENTS. 14. ALL DOORS ARE TO BE T-0" WIDE UNLESS NOTED OTHERWISE ON PLANS. 15. ALL DESIGNATED EXIT DOORS SHALL BE NON -LOCKING AGAINST EGRESS. z 16. ALL THUMB LATCH LOCKING DEVICES ON MEANS OF EGRESS DOORS SHALL BE ACTIVATED BY NO MORE THAN ONE QUARTER (1/4) TURN. ROUT ALL GLASS IN DOORS SHALL BE TEMPERED. C�JN17. CORRESPONDING GRADE N ° 18. ALL DOORS & HARDWARE SHALL COMPLY WITH LOCAL BARRIER FREE LAWS AND THE AMERICANS WITH DISABILITIES ACT. 2 BRAILLE PER CBC z_ 19. ALL WOOD DOORS TO BE PARTICLEBOARD CORE DOORS; PERFORMANCE GRADE: EXTRA HEAVY DUTY; AESTHETIC GRADE: PREMIUM. 11B-73.3 AND 11B-703.4 ------ ___ 20. ALL DOORS TO BE UNDERCUT MIN. 3/4" OR REQ'D BY CODE U.N.O. ............ -� 21. ALL DOOR FRAMES SHALL BE ONE PIECE WELDED 16 GA. H.M. - PAINT P-5. 22. HOLLOW METAL DOORS SHALL BE 18 GA. FACE SHEETS EXTERIOR DOORS TO BE GALVANIZED & INSULATED. 23. ALL DOORS, FRAMES & HARDWARE TO BE PROVIDED AND INSTALLED BY GC. 24. ALL DOORS TO BE EQUIPPED W/ MIN. (3) DOOR SILENCERS ON LATCH -SIDE OF DOOR FRAME. 25. ALL HARDWARE TO BE BRUSHED OR SATIN -FINISH STAINLESS STEEL U.N.O. 26. EXTERIOR SIDE OF ALL PERIMETER WALL DOORS & FRAMES TO BE PAINTED AS APPROVED BY LANDLORD. COORDINATE COLOR W/ EXISTING EXTERIOR DOORS & FRAMES. 27. ALL FIRE DOORS SHALL BE SELF OR AUTOMATIC CLOSING AS REQUIRED BY 2019 CBC SECTION 716.5.9 NOTE: DOTS SHALL BE 1/10" O.C. IN EACH CELL W/ 2/10" SPACE BETWEEN CELLS, MEASURED FROM THE 28. ALL FIRE DOOR SHALL BE SMOKE -ACTIVATED DOORS AS REQUIRED BY 2019 CBC SECTION 716.5.9.3 #13. SECOND COLUMN OF DOTS IN THE FIRST CELL TO THE FIRST COLUMN OF DOTS IN THE SECOND CELL. DOTS SHALL BE RAISED A MIN. 1/40" ABOVE BACKGROUND. DOTS SHALL BE ROUNDED OR DOMED TACTILE EXIT ROUTE SIGN SCALE 22 WINDOW GENERAL NOTES 6"=T-0' DOOR & FRAME (WHERE APPLICABLE) 1/4" TEMPERED GLASS VISION PANEL (WHERE APPLICABLE) SIGNAGE, MOUNT AS TO ALLOW A PERSON TO APPROACH WITHIN 3" OF SIGNAGE WITHOUT ENCOUNTERING DOOR SWING OR PROTRUDING OBJECTS. (SEE DTLS 23-25) TOP OF FRP @ 48" AFF GENERAL POWER & COMMUNICATION RECEPTACLES ARMOR OR KICK PLATE (WHERE APPLICABLE) d w d w 0 M SWITCH THERMOSTAT 4" Lo co DIRECTION OF APPROACH FINISH FACE OF WALL OR OTHER OBSTRUCTION THIS ADDITIONA REQUIRED IF BC LATCH ARE PRO PULL SIDE n PUSH SIDE NOTES: 1. MOUNT FIRE EXTINGUISHER CABINET SO THAT THE HIGHEST OPERATING PART OF THE CABINET IS 54" A.F.F. MAX. 2. FIRE EXTINGUISHER CABINET VERIFY ROUGH OPENING IN THE FIELD 5/8" GYP. BD. o/ METAL STUD FURRING BEHIND F.E.C. TO MAINTAIN FIRE RATING FIRE EXTINGUISHER CABINET VERIFY ROUGH OPENING IN THE FIELD 5/8" GYP. BD. EA. SIDE o/ METAL STUD FRAMING - SEE WALL LEGEND NON -RATED WALL 1-HR RATED WALL CONDITION CONDITION SCALE FIRE EXTINGUISHER CAB 11/2"=1'-0" 1. EACH LITE SHALL BEAR THE MANUFACTURER'S LABEL DESIGNATING THE TYPE AND THICKNESS OF THE GLASS. 2. GLASS SHALL BE FIRMLY SUPPORTED ON ALL FOUR SIDES. 3. FIELD MEASURE ALL OPENINGS PRIOR TO FABRICATIONS. 4. ALL GLAZING WITHIN A 24" ARC OF EITHER EDGE OF A DOOR AND WITHIN 60" OF THE FLOOR SHALL BE TEMPERED. FINISH GENERAL NOTES a 1. NO FINISH SUBSTITUTIONS SHALL BE MADE UNLESS APPROVED BY THE ARCHITECT IN WRITING. a cD 2. DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME RETARDANT CONDITION. 3. SUBMIT SAMPLES OF ALL FINISHES FOR ARCHITECT'S APPROVAL PRIOR TO ORDERING. orf 4. NOTIFY ARCHITECT IMMEDIATELY OF ITEMS WITH LONG LEAD TIMES. Lu a 5. ALL PAINT FINISH OF METAL PARTS OF DOORS, HANDRAILS, AND PERIMETER ENCLOSURES SHALL BE SEMI -GLOSS U.N.O. O 6. WHERE PAINT COLORS CHANGE, CORNERS ARE TO BE CUT IN FREE OF ANY OVERLAP. 7. PRIOR TO INSTALLATION OF ANY WALL COVERING, SURFACES SHALL BE PREPARED AND SEALED PER MANUFACTURERS RECOMMENDATIONS. CD 8. CONTRACTOR TO VERIFY CONDITION AND LEVEL OF FLOOR SO AS TO RECEIVE NEW FINISHES WITHOUT BOWING AT FLOOR OR WALL BASE. CONTRACTOR IS RESPONSIBLE FOR ALL FLOOR PREPARATION. 9. ALL CARPETING SHALL BE INSTALLED WITH GLUE DOWN METHOD U.N.O. W Y a w O IL Lu 0 a o LLI U) > U) w cc W Q V V 0 w pC �C Q 0 Q U) W � ~ � J L u ., Q _j W Wm U 0 U Cd U) cc U) W 0�_ 00 0 z DATE: xxxx JOB NO.: SEA-21-011 10. CONTRACTOR TO PROVIDE PREFORMED RUBBER BASE CORNERS. DO NOT CUT OR BEND STRAIGHT BASE TO MAKE CORNERS. 11. FLOOR FINISHES TO CONTINUE UNDER OPEN AREAS OF MILLWORK, INCLUDING SINK AREA AND ALL UNDER COUNTER EQUIPMENT AREAS. 12. CONTRACTOR TO SUBMIT VCT AND TILEPATTERN PLANS TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION 11 A901 DOORS HEAD (JAMB SIM) SCALE 2 3"=T-0' TYP MOUNTING HEIGHTS WALL BASE SCALE 21 1/2" = 1'-0" SCALE 16 CLEARANCE AT DOOR 1/4"=1'-0' AT METAL DECK ONLY (4)# 12 S.M.S. EACH FLUTE (4 TOTAL) k L4x4xl4GA.xl'-0" LONG STUD KICKER SIZE & SPACING PER WALL SECTIONS W/(4)#10 S.M.S. TO Lx U.N.O. AT METAL DFCK ONLY (4) #12 S.N L4x4xl4GA STUDKICK WALL SEC Lx U.N.O. PERPENDICULAR TO FLUTES SCALE ^ KICKER TO DECK 1"=1'0' L 3 5/8" 20 GA. METAL STUD BRACING @8'-0" O.C. EA. SIDE STAGGERED SUSPENDED CEILING - SEE REFLECTED CEILING PLAN FOR HEIGHTS 5/8" GYP. BD. 0/ 3 5/8" 20 GA. METAL STUD FRAMING 8 GA. HANGER WIRE TO STRUCTURE ABOVE, 4'-0" O C WITH 4 WIRFS SPALYEE DEG. MA 20 GAUG FURRING CHANNE O.C. 20 C 1 1/2" CO STEEL A' GAUGE TYPE "S" 5/8" GYP SUPPOR,L-u SCALE ^ G.B. SUSPENDED CEILING T, 1'-0' L 0 "UNATTACHED WALL" ARMSTRONG BERC2 ICC-ESR-1308 8" MAX HEAVY DUTY T-BAR SYSTEM TO COMPLY WITH PROVISIONS OF �® ASTM C 635 AND ASTM C 636 AND SEC. 1613.1 OF THE CBC. ° PERIMETER HANGER WIRE ° 3/4" \ 8 AT ALL MAIN RUNNERS ° �\ AND CROSS TEES 0 SEISMIC CLIP SYSTEM ANCHOR TO WALL OR SOFFIT W/ #6 SCREWS @ 24" O.C. SUSPENDED CEILING GRID WHERE WALL REMAINS WALL OR SOFFIT UNATTACHED TO CLOSURE ANGLE, 3/4" CLEARANCE TO BE MAINTAINED CLOSURE ANGLE MOLDING 7800 HANGER AND PERIMETER WIRES SHALL BE PLUMB WITHIN 1 IN 6 UNLESS COUNTER SLOPING WIRES ARE PROVIDED UN -ATTACHED ANGLE SCALE 1 9 3"=1'0' "ATTACHED WALL" ARMSTRONG BERC2 ICC-ESR-1308 8" MAX. HEAVY DUTY T-BAR SYSTEM TO COMPLY WITH PROVISIONS OF ASTM C 635 AND ASTM C 636 AND m SEC. 1613.1 OF THE CBC. o e ° ®e ° 7/8" WALL OR SOFFIT ° SEISMIC CLIP SYSTEM ANCHOR TO WALL OR SOFFIT W/ #6 SCREWS @ 24" O.C. PERIMETER HANGER WIRE AT ALL MAIN RUNNERS AND CROSS TEES ° SUSPENDED CEILING GRID TIGHT SCREW WHERE WALL REMAINS UNATTACHED TO CLOSURE ANGLE, 3/4" CLEARANCE TO BE MAINTAINED CLOSURE ANGLE MOLDING 7800 HANGER AND PERIMETER WIRES SHALL BE PLUMB WITHIN 1 IN 6 UNLESS COUNTER SLOPING WIRES ARE PROVIDED SCALE ATTACHED ANGLE1 3"=1'0' EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTIONS, SPRINKLER HEADS AND OTHER PENETRATIONS, SHOW A 2" OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMMODATE 1" OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS IS PERMITTED TO BE PROVIDED AT THE TOP OF THE SPRINKLER HEAD EXTENSION. SLOT END OF TUBE TO FIT OVER RUNNER o NOTE: 2X4 SUB-PURLINS ARE NOT TO BE USED FOR CEILING ATTACHMENT SUSPENDED CEILING SYSTEM - SEE REFLECTED CEILING PLAN ° a, MAIN RUNNER CROSS RUNNER SCALE 12 GA. WIRE SPLAYED IN (4) CEILING H D R TRANSITION 1 1/2" - 1'-0" 22 DIRECTIONS 90 DEGREES APART AT 12'-0" O.C. HEAVY DUTY T-BAR SYSTEM TO COMPLY WITH PROVISIONS OF ASTM C 635, ASTM C 636, ASCE 7-10 AND CISCA REQUIRED LOCATIONS OF COMPRESSION STRUTS - TYP. CEILING SYSTEMS ARE TO BE ATTACHED AT 2 ADJACENT WALLS OR SOFFITS I ACOUSTICAL CEILING TILE WITH WALL ANGLE METAL STUD. TYPE "X" GYPSUM BOARD TAPED AND / FINISH SMOOTH FOR PAINT FINISH. ACOUSTICAL CEILING TILE WITH / WALL ANGLE a U d w w SUSPENDED CEILING SYSTEM - SEE REFLECTED CEILING PLAN 18 10. ATTACHED UN -ATTACHED 12'-0" O.C. TYP. 19 A10 0 CONT. COVE CAP SHEET VINYL (SV-2 MITER COVE BASE OUTSIDE CORNER; HEAT WELD (TYP.) SHEET VINYL (SV-1) EXISTING SLAB TO REMAIN #4 REBAR @ 12" O.C. ALTERNATE SIDES NEW CONCRETE TO MATCH EXISTING CONCRETE SAW -CUT AND REMOVE EXISTING SLAB AS REQUIRED 4 Lu d" V Lu ° d BACK FILL TO BE CONCRETE SLURRY OR 95% COMPACTED SAND REPLACE BASE TO MATCH EXISTING MATERIAL AND COMPACTION. REPLACE ALL VAPOR BARRIERS DRILL 3/4" DIAMETER HOLE INTO EXISTING CONCRETE & "POR-ROK" SCALE SAW -CUT SLAB REPAIR 11/2"=1'-0" 10 METAL STUD PAR"` SEE WALL SCHEDi WALL PROTECTIO CLEAR SEALANT CONT. COVE CAP HIGH ROLLED INTI SEE FINISH SCHE[ COVE FILLER STIR SHEET VINYL FLO, SEE FINISH SCHE[ METAL STUC SCHEDULE HIGH STAND FINISH SCHE FLOOR FINIr CON RETE)S Q w ry Q z w Q w co NOTES: 1. MOUNT FIRE EXTINGUISHER CABINET SO THAT THE HIGHEST OPERATING PART OF THE CABINET IS 54" A.F.F. MAX. 2. FIRE EXTINGUISHER CABINET VERIFY ROUGH OPENING IN THE FIELD 5/8" GYP. BD. o/ METAL STUD FURRING BEHIND F.E.C. TO MAINTAIN FIRE RATING FIRE EXTINGUISHER CABINET VERIFY ROUGH OPENING IN THE FIELD 5/8" GYP. BD. EA. SIDE o/ METAL STUD FRAMING SEE WALL LEGEND cD z Q w a 0 0 v NONRATED WALL 1-HR RATED WALL CONDITION CONDITION FIRE EXTINGUISHER CAB SCALE 11/2"=1'-0' NOTE: USE MOLD RESISTANT GYP. WALLS TOP TRACK SECU WALL BRACE W/ (; METAL SCREWS SOUND INSULATI( SCALE BASE - SHEET VINYL 3"=1'0' 9 5/8" THK MOISTUF RESISTANT BD TC PLUMBING WALL ( FRAMING - SEE W WAINSCOTTING - FINISH SCHEDULE SCALE 8 RESILIENT BASE - CARPET SOLID SURFACE WALL CAP- SEE FINISH SCHEDULE FIRE -RETARDANT WOOD BLOCKING 5/8" TYP. X GYP. BD. EACH SIDE 0/ METAL STUD FRAMING - SEE WALL LEGEND BRACING @ 4'4" O.C. MAX. SEE DETAIL 5 THIS SHEET BOTTOM TRACK W/ .145 DIA. X 1 1/4" POWER DRIVEN FASTENER @ 24" O.C. PER ICC-ESR 1799 WALL BASE - SEE FINISH SCHEDULE CONT BED OF MOLD RESISTANT SEALANT UNDER CHANNEL- (USE FIRE CAULKING AT RATED WALLS) FINISH FLOOR - SEE FINISH SCHEDULE BOTTOM TRACK V POWER DRIVEN F O.C. PER ICC-ESR WALL BASE - SEE FINISH SCHEDULE CONT BED OF MO SEALANT UNDER FIRE CAULKING A' FINISH FLOOR - SI SCHEDULE WA L L TYPE B SCALE3" = 1'-0' PROVIDE BLOCKING AS NEEDED AT ROOF LEVEL NOTE: USE MOLD & MOISTURE RESISTANT GYP. BD. SEE STRUCTURAL DWGS FULL HEIGHT AT ALL WET WALLS (5/ S1.2) 7„ SLIP TRACK W/ (2) #8 SMS INTO STRUCTURE, 1 1/2" MIN. PENETRATION ICC-ESR #1042 R-13 INSULATION (FULL HEIGHT) - SECURE IN PLACE PROVIDE ALTERNATE BID FOR SOUND INSULATION AT ALL EXAMS, & PRIVATE OFFICES, SUSPENDED ACOUSTIC CEILING SYSTEM - SEE REFLECTED CEILING PLAN Q 5/8" TYPE'X' GYP. BD. w ONE SIDE 0/ FULL HT. METAL STUD FRAMING - SEE WALL LEGEND SOUND INSULATION FULL HEIGHT OF WALL - WHERE OCCURS SEE WALL LEGEND BOTTOM TRACK W/ .145 DIA. X 1 1/4" POWER DRIVEN FASTENER @ 24" O.0 PER ICC-ESR 1799 RESILIANT BASE -SEE FINISH SCHEDULE FINISH FLOOR - SEE FINISH SCHEDULE U) z w 2 Z) U) z U) X W U w x U Cc Q a w H N uj d of zU) a 0-� 0- m,: U) z_ F Q 0 N W w }2 J F w a w uj d0 O 2 N o dm O N U p 2 d = CDF W U Lo CC °° w X = w av � F-N 0 z ¢Ir Z 0w ~ V w F w 0 � d } U) Z clU'l Q N ¢O m U)L v CD o0 W z w Z j Q � Q m w 0 U) Z w J F Q U) 0 T N W Z p0 c cnz w c > � cn Q 0 Ca cn >. c � Q Lu a a Wuj 13 W U. 0 T 0 M co Y a w c O ILL Lu 0 a o W U) U ) w c ME w Vw 0 w J LL w of w DATE: xxxx JOB NO.: SEA-21-011 J Q W 0 0 z J W 06 J J Q SCALE ^ 1 CEILING HDR TRANSITION 3"=1'-0' L SCALE SUSPENDED CEILING 3"=1'-0' 16 SCALE SHEET VINYL COVE BASE 11/2"=1'0" 11 ACOUSTICAL SEALANT BOTH SIDES - (USE FIRE CAULKING AT RATED WALLS) WALL TYPE C SCA1 E 6 WALL TYPE A SCA1 E 0 SLOTTED TRACK W/77 - (1) SCREW TO EA STUD FLANGE, TYP PERPENDICULAR TO DECK (CONC SLAB SIM) STL BEAM W/ FIREPROOFING (2) SCREWS AT EA Z FURRING PARALLEL TO BEAM 2/3 d MI "d c'TEELDECK LOTTED W/ (1) SCREW TUD FLANGE TRACK, T SCREW AT EA LOW LUTE,STAG PERPENDICULAR TO DECK WIDTH AS REQ TO Ek "'^` DECK FLUTES 18 GA CONT PL W/ SCREWS @ 12" OC,) DECK FLUTES SCREWS @ 12" OC,! PARALLEL TO DECK CONC 0/ STL DECK PAF @ 12" OC STAGGER 16GA x 3" WIDE PL @ 48" OC & 6" MAX FROM END OF TRACK AND JAMB STUDS W/ PAF INTO EA LOW FLUTE Z-FURRING x 18 GA @ 24" OC W/ MIN DEPTH EQUAL TO FIREPROOFING THICKNESS W/ (2) PAF OR SCREWS TO STEEL BEAM STEEL BEAM SLOTTED TRACK W/ (1) SCREW TO EA STUD FLANGE, TYP PAF OR SCREWS @ 12" OC, STAG SCREWS @ 12" OC, STAG PARALLEL TO BEAM dr-° MAX d 18GAx� CONT BENT PL SCREWS @ 12" OC, STAG 45' MAX d 18 GA CONT BENT PL JAMB STUDS AT ADJACENT WHERE WALL STOPS @ OPENING SHALL BE TAKEN AS L1 A10.3 CEILING FOR EA OPENI G+L2 OR AT /FRMGSEPARATE JAMBS A?0.3 DECKOOF ----- ADJACENT- `o OPENING i _7\ D�UCT�I QTF(E2 10.3i 12 A10.3 WINDOW, 900R S M( , SILLS TYP A10.3 L1 L2 L TYP WALL STUDS INFILL STUDS ABV & BLW OPNG TO MATCH TYP STUDS FRAMING ELEVATION SIM 6 INFILL AT RATED WALLS MATCH WALL A10.3 STUD SIZE AND SPACING 0 N DUCT-/ 6 8 12 HER A10.3 A10.3 A10.3 TYP A10.3 WINb(OW TYP DOOR 11 TA10.3 13 A 10.3 L BRIDGING, SPACED AT 4'-0" MAX OC VERT. OMIT WHERE SHEATHING OCCURS BOTH SIDES. BOTTOM TRACK PER 21 A 10.3 19 zo NOMINAL SIZE SSMA DESIGNATION 2 1/2"x 20GA 2505125-33 3 5/8"x 25GA SEE NOTE 2 3625125-18 3 5/8"x 20GA 3625125-30 or 362S125-33 3 5/8"x 18GA 3625125-43 3 5/8"x 16GA 3625125-54 4" x 20GA 40OS125-30 or400S125-33 4" x 18GA 40OS125-43 4" x 16GA 40OS125-54 6" x 20GA 60OS125-30 or600S125-33 6" x 18GA 60OS125-43 6" x 16GA 60OS125-54 8" x 18GA 80OS125-43 8" x 16GA 80OS125-54 10" x 16GA 1000S162-54 NOTES 1. SEE ADJACENT TABLE FOR SSMA DESIGNATION OF MEMBERS REFERENCED IN PLANS / DETAILS 2. STUDS SHALL BE SPACED AT 24" OC MAX EXCEPT FOR WALLS WHERE "H" EXCEEDS 9'-6": 3 5/8" x 25GA STUDS SHALL BE SPACED @ 12" OC MAX 3 5/8" x 20GA STUDS SHALL BE SPACED @ 16" OC MAX 3. DETAILS AND MEMBER SIZES SHOWN ASSUME WALL WT OF 8 PSF AND DEFLECTION LIMITED TO H/120. 4. WALLS SUPPORTING TILE OR OTHER BRITTLE FINISHES WHERE DEFLECTION IS LIMITED TO H/240 SHALL BE THE FOLLOWING AT A MINIMUM: H = 9'-6" MAX: 3 5/8" x 20GA MIN @ 16" OC MAX H = 16-6" MAX: 3 5/8" x 18GA MIN @ 16" OC MAX 5. WHERE DETAILS INDICATE SUPPORT OF CEILING / CASEWORK, THIS ASSUMES CASEWORK IN ADDITION TO CEILING FRAMING W/ A 12'-0" MAX SPAN EACH SIDE OF WALL. ASSUMED CEILING LOAD IS: DL = 10PSF; LL = 10PSF. 6. STUDS SUPPORTING CEILINGS OR WALL MOUNTED CASEWORK / EQUIPMENT SHALL BE 20GA MIN. 7. THIS TABLE IS FOR GENERAL REFERENCE ONLY; GENERAL CONTRACTOR TO VERIFY PROPOSED STUD GAUGE AND SPACING WITH STUD MANUFACTURE. 7. LIMITING HEIGHTS SHOWN ARE TESTED FOR INTERIOR NOW LOAD BEARING PARTITIONS SHEATHED FULL HEIGHT WITH 1/2" THICK GYP. BD. REFER TO NOTE 37/PARTITION GENERAL NOTES FOR GYPSUM BOARD REQUIREMENTS. 4. REFER TO SOURCE DOCUMENT FOR VALUES OTHER THAN THOSE SHOWN. L 1 1/2 x 1 1/2 x 16 GA AT SPACING PER TABLE END OF FULL -DEPTH BLKG @ 12'-0" OC AND AT (4) SCREWS EA CUT FLANGES & BEND WEB TO EA SUPPORTING STUD WALL � STRAP ENDS OR SPLICES, SEE "TYP STRAP TO BLKG, W/ (3) SCREWS EA LEG --_ FORM A 1 1/2" OVERLAP, ATTACH W/ WIDTH AS REQ STEEL STUD/JOIST BLOCKING" DETAIL TYP --- ___ TOGA/ (1) SCREW PER EA 2" OF DEPTH, CUT TOP & BOT TOP TRACK CONT ONE TYP FOR TOP & BOT TRACK FLG OF STUDS & TO ENGAGE (2) (1) SCREW EA STRAP TO STUD, - DECK FLUTES TYP (IF FILLET WELDS ARE USED PIECE AS AN ALTERNATE, USE LAP WEB OVER IN STEAD OF SCREWS, WELD ALT STUD WALL PER ARCH L1 1/2xl 1/2xl6 GA W/ (3) SCREWS EA EA JAMB STUD SIDES OF STRAP AT EA STUD) (20 GA MIN) LEG) SUPPORT PER TABLE (1) SCREW PER SEE OTHER DETAILS FOR z x + EA 2" OF DEPTH BRIDGING SPACING & x (2) SCREWS T&B - AT EA JAMB x ` BOT TRACK, CONN PER STUD ES (2) SCREWS TO LOCATIONS 4. EA PL, TYP 4. . x ` "TYP CFSF WALL CONN r x AT HIGH FLUTE PAF @ 12" OC STAGGER AT LOW FLUTE PARALLEL TO DECK ,d45 DEG MAX d 18GAx CONT BENT PL NOTES: 1. SLOTTED TRACK SHALL HAVE 2 1/2" LEGS W/ 1/4"x 1 1/2" VERT SLOTS @ 1" OC AT EA LEG. 2. SLOTTED TRACK TO BE 20GA MIN. 3. TOP OF STUD TO BE 3/4" CLEAR FROM SLOTTED TRACK WEB. 4. PROVIDE (1) SCREW TO EA STUD FLANGE, LOCATE SCREW AT CENTER OF SLOT. 5. NO ATTACHMENT OF SHEATHING OR FINISHES IS PERMITTED TO FRAMING WITHIN 4" OF THE TOP OF THE SLOTTED TRACK. SCALE 2 2 1"=1'0' TYP CFSF WALL CONN AT TOP FOS TO FOC TO BE 1/2" ES AT 6" & LARGER STUDS, 0"-__- AT STUDS LESS THAN 6" STEEL STUD WALL, x AT BASE DETAIL D- , EQ CONC SLAB OR CONC x L 1 1/2 x 1 1/2 x 16 EQ O/ STEEL DECK GA W/ (2) SCREWS JAMB STUDS EA LEG, TYP / 6 3/4" FOR 8'-0" WALLS 5 1/4" FOR ALL OTHER x II 1 1/2" WIDE x 1/2" STRAP SPLICE, WALLS II DEEP x 16 GA U- WHERE OCCURS 1" _v CHANNEL, FULL 1 1/2" x 20 GA CONT STRAP CL CHANNEL & BASE LENGTH OF WALL FULL LENGTH OF WALL, TYP PLATE (OMIT ON SIDE W/ SHEATHING D FOR STUDS 18 GA AND BASE PLATE WIDTH - THINNER, UNO) PER TABLE STUD, SEE PLAN 5/8" BASE PL W/ "' MAXIMUM SPACING OF SUPPORTS MAX WALL HEIGHT BASE PL WIDTH SUPPORT SIZE STUD WALL 8'-0" 6-0" 5'-0" 4'-0" - - 4'-0" 6-8" 3 1/2" C3x3.5 3 5/8" 2' 8" 4' 0" 6' 8" 8' 0" 5 1/2" C44.5 6" 4-4' 6-8" 8'-0" - 7" C44.5 8" (1) SCREW TO EA STUD FLANGE, TYP TRACK, CUT WEB & LAP FLG OVER EA JAMB STUD (1) SCREW AT EA JAMB (2) 1/2" DIA "HILTI" KB-TZ STUD ES ACCEPTABLE FOR 6" & SMALLER STUDS, ACCEPTABLE FOR ALL STUDS SIZES W/ 2" EMBED 18GA AND THINNER AND THICKNESSES, UNO 3/16 NOTES: U-CHANNEL BRIDGING AT STUDS STRAP BRIDGING AT STUDS 1. EXPANSION ANCHORS MUST BE INSTALLED WITH SPECIAL INSPECTION STUD / TRACK HDR BUILT-UP HEADER 2. DO NOT USE THIS DETAIL FOR WALLS USED AS GUARDRAILS OR WALLS WITH GRAB BARS SCALE SCALE TYP STEEL STUD BRIDGING 3/4"V 18 TYP CFSF PARTIAL WALL CONN 34"=V-0. 13 TYP CFSF HD. CONN TO JAMBS SCALE 1'0" WHERE BRACE IS NOT AT LOW FLUTE, PROVIDE 16 GA PL CONT OVER 2 FLUTES MIN WITH (2) FASTENERS AT EA FLUTE CONC FILL WHERE OCCURS, SEE PLAN STEEL DECK, SEE PLAN r + - L 1 1/2 x 1 1/2 x 16GA, EXTEND OVER (3) FLUTES 3 SCREWS, MIN AT BARE DECK, (2) TYP TO FLUTES MIN AT CONC BRACE FILLED DECK W/ (1) FASTENER TO EA FLUTE BRACE L 1 1/2 x 1 1/2 x 16GA, 8" LONG W/ (3) FASTENERS TO FLUTE AT BARE DECK, (2) FASTENERS TO LOW FLUTE AT CONC FILLED DECK. WHERE BRACE IS NOT AT LOW FLUTE, ATTACH TO CONT PL W/ (3) SCREWS NOTES 1. FASTENERS SHALL BE: AT BARE DECK: (1) SCREW AT CONC-FILLED DECK: 3/8" DIA "HILTI" KB-TZ W/ 2" EMBED 2. DECK MAY SLOPE, SEE PLANS SCALE TYP BRACE CONN TO DECK v=1'-0" SEE PLAN o 1/2" DIA SCREW CL STUD & w ANCHOR @ 32" OC W/ 3 THREADED ROD 0 ADD FLAT STUD W/ SCREWS @ 12" 1 1/4 MIN EMBED OC WHEN BRACE LENGTH EXCEEDS � II O I PAF @ 32" OC I STEEL I a `�' 8'4% TYP (MAX)1 � � ( ) 1/2 �� (MIN) STEEL TRACK _ TRACK Al CONC CURB CONC SLAB ON 0 `o GRADE /CONC FILL 0/ STEEL DECK BRACE SAME SIZE & GA AS STUDS (20 GA MIN) (STAGGER @ 48" OC) ��� CN FOR CONN @ TOP; SEE "TYP BRACE + + cc CONN TO DECK" "MIN. #4 CONT2 LL L 1 1/2 x 1 1/2 x 16GA W/ (3) SCREWS / EDGE OF SLAB OR 1/2" DIA THREADED ROD W/ EA LEG, TYP �/ DEPRESSED SLAB STEEL WASHER @ 32" OC - WHERE OCCURS. IF EMBED IN EPDXY INTO (E) PROVIDE (1) SCREW TO EA STUD DEPRESSED OVER 2", CONC SLAB (NO TEST LOAD) FLANGE BOLT TRACK AS AT CURB WITHOUT CURB WITH (E) CURB WITH CURB STUD WALL, SEE PLAN NOTES 1. TWO ANCHORS MIN FOR EA PIECE OF TRACK, LOCATED 6" FROM ENDS. 2. PROVIDE ADDITIONAL ANCHOR 6" FROM EA SIDE OF ANY SPLICES, HOLES OR NOTCHES IN TRACK 3. PROVIDE (1) SCREW FROM TRACK TO EA STUD FLANGE. 4. SCREW ANCHORS SHALL BE "SIMPSON" TITEN HD OR "HILTI" KH-EZ. 5. EPDXY SHALL BE "SIMPSON" SET-XP OR "HILTI" HY-200. 17 NUMBER OF JAMB STUDS EACH SIDE OF OPENING MAX WALL HEIGHT, H 9-4' 16-4' STUD DEPTH 3 5/8" or 4" 6" 3 5/8" or 4" 6" JAMB GA 25 20 18 16 20 18 16 20 18 16 20 18 16 z 4' 2 1 1 1 2 1 1 3 2 1 2 1 1 J vow 8' 2 2 1 1 2 1 1 4 3 2 3 2 1 o_ U c) 12' 3 2 1 1 3 1 1 - 3 2 - 2 2 0 z 0 o� 4' - 2 1 1 2 1 1 4 2 2 2 2 1 xQ Zo � �w wU) 8' 2 2 1 2 1 1 4 3 4 2 2 12' 3 2 1 3 2 1 4 3 2 CONTRACTOR OPTION IN LIEU OF PLATES & SCREWS 1 1/2" x 18GA STRAP AT 24" OC FULL HT EA SIDE OF JAMB STUDS W/ (1) SCREW TO EA FLANGE SINGLE TRACK SILL CONDITION WHERE OCCURS CUT FLANGES & BEND WEB TO F( A 1 1/2" OVERLAP, ATTACH W/ (1) SCREW PER EA 2" OF DEPTH, TYP FOR TOP & BOT TRACK (AS AN ALTERNATE, USE L1 1/2xl 1/2xl6 GA W/ (3) SCREWS EA LEG) ADDLSTUD ADDL STUD WHERE OCCURS PROVIDE ADDL FASTENER @ TOP & BOT TRACK TO STRUCTURE WITHIN NOTES: 6" OF JAMB 1. PROVIDE FASTENERS SPACED @ 12" OC WHERE SHOWN. 2. ALL MATERIAL IN HEADERS TO BE 20GA MIN, LINO. TYP CFSF JAMBS SCA1 O 12 TYP CFSF HEADERS SCALE 1' 0" OPENING 4' MAX 8' MAX 12' MAX WIDTH, L TYP TYP TYP STUD TRACK TRACK o TYP STUD 600S125: TYP TRACK W/ TYP TYP ~ 2 1/2" FLANGE TRACK TRACK HA1 HA2 HA3 TYP TYP TYP o z Y �z� TRACK 60OS125-30 OR TRACK 60OS125-54 TRACK 1000S162-54 J w w ui 60OS125 33 TYP TRACK TYP TRACK�� o 0 TYP = TRACK HAC1 HAC2 HAC3 TRACK, CUT WEB & LAP FLG OVER EA JAMB STUD OPENING WIDTH, L 4' MAX 8' MAX 12' MAX TYP TYP TYP STUD -� TRACK TRACK TYP TYP SILL \� TRACK OR 18GA TRACK I I r SA1 SA2 r SA3 (1) SCREW AT EA JAMB STUD ES NOTES: STITCH -WELD 1. PROVIDE FASTENERS SPACED @ 12" OC WHERE SHOWN. STUD TO 2. ALL MATERIAL IN SILLS TO BE 20GA MIN, UNO. 1 /8 1-12 TRACKS, TYP uj IL of ¢ zU) z CL C� Umr )mr Zto t F 0 LL W N w >2 J F w Q w Lu L rn O 2 o dm O N U p 2 d 2 CDF w CC? w x �w aw w z 0 ~ cn O O z O ¢� z U w ~ cn w F U dO } °' U) z c oa co ¢O m U)1 v on m Z w w z �z Q w Q Uz w J = J F U) 0 N W H Z F__ p0 c TYP CFSF STUD WALL SCALE 4 z Z 1"=10,. 5W w- m W >_ _ cn � Q 0 GYP BOARD WHERE OCCURS U = Q STEEL OR WOOD STUD WALL, SEE PLANS Q CONCRETE CURBLu Q Z X uj W CONT L3/4X1 1/2X22 GA (LLV) GALV SHEET METAL \ W W IO W PAF @ 32" OC & 8" FROM ENDS -------------------- U. O 1/2" CLR WHERE GYP BOARD r 0 OCCURS (0" AT STUD WIDTHS 4" OR M LESS) v co 8 TYP GYP BD. ATTACH. AT CURB 1 SCALE o 3 COLD -FORMED STEEL FRAMING 1. THE DESIGN, INSTALLATION AND CONSTRUCTION OF COLD -FORMED STEEL FRAMING SHALL BE IN ACCORDANCE WITH THE FOLLOWING AISI NORTH AMERICAN STANDARDS: S100 - SPECIFICATION FOR THE DESIGN OF STRUCTURAL MEMBERS S200 - GENERAL PROVISIONS S211 - WALL STUD DESIGN S212 - HEADER DESIGN 2. ALL PRODUCTS SHALL BE MANUFACTURED BY A CURRENT MEMBER OF THE "STEEL STUD MANUFACTURERS ASSOCIATION" (SSMA) OR "STEEL FRAMING INDUSTRY ASSOCIATION" (SFIA) WITH DIMENSIONS, SECTION PROPERTIES AND MATERIALS IN COMPLIANCE WITH THE AISI D100 MANUAL OF COLD -FORMED STEEL DESIGN. 3. PROVIDE ALL ACCESSORIES INCLUDING, BUT NOT LIMITED TO, TRACKS, CLIPS, WEB STIFFENERS, ANCHORS, FASTENING DEVICES, RESILIENT CLIPS, AND OTHER ACCESSORIES REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, AND AS RECOMMENDED BY THE MANUFACTURER FOR THE STEEL MEMBERS USED. 4. STEEL MEMBERS AND COMPONENTS SHALL BE GALVANIZED ZINC -COATED PER ASTM A653 WITH G40 COATING WEIGHTS LINO W Y a 2E w O IL 0 a o LLl U) > w 5. STEEL MEMBERS 20 GA (0.030" THICKNESS) OR LIGHTER SHALL BE MANUFACTURED PER A1003 NON-STRUCTURAL GRADE 33 (NS33), 20 GA (0.033" THICKNESS) AND 18 GA PER A1003 STRUCTURAL GRADE 33, TYPE H (ST33H) AND 16 GA OR HEAVIER PER A1003 STRUCTURAL GRADE 50, TYPE H (ST50H). 6. THE MINIMUM UNCOATED STEEL THICKNESS AS DELIVERED TO THE JOBSITE SHALL BE: 25 GA = 0.018", 22 GA = 0.027", 20 GA = 0.030", 18 GA = 0.043", 16 GA = 0.054". 14 GA = 0.068", 12 GA = 0.097". 7. STUDS/JOISTS SHALL HAVE WEB PUNCH -OUTS AT 24" OC AT MID -DEPTH. PUNCH -OUTS SHALL Z NOT EXCEED 1 1/2" IN WIDTH, AND 4" IN LENGTH. NO OTHER OPENINGS IN STUDS/JOISTS ARE PERMITTED UNLESS SPECIFICALLY DETAILED. 8. TRACK SHALL MATCH STUD/JOIST DEPTH & GAGE, AND FLANGE WIDTH SHALL BE 1 1/4", TYP, UNO. (%� 2 ALL TRACKS TO BE UNPUNCHED WITH SOLID WEBS. (n cc 7 9. FASTENING OF FRAMING COMPONENTS SHALL BE WITH SELF -DRILLING SELF -TAPPING SCREWS w U. OR WELDING. WHERE DETAILS CALL FOR SCREWS, THE MINIMUM SIZES SHALL BE AS FOLLOWS: #6 FOR 22 GA OR LIGHTER MATERIAL, #8 FOR 20 GA MATERIAL, #10 FOR 18 & 16 GA MATERIAL, Q & #12 FOR 14 GA OR HEAVIER MATERIAL, TYP UNO. SCREW SIZE IS DETERMINED BY THE GA W OF THE THICKEST PART BEING JOINED UNO. INSTALL SCREWS WITH THE HEAD IN CONTACT WITH 0 THE THINNEST PART BEING JOINED UNO. AS AN ALTERNATE, STEEL MEMBERS 18 GA OR HEAVIER MAY BE WELDED WITH A 1/2" LONG WELD (FILLET OR FLARE GROOVE) INSTEAD OF EACH SCREW, 0 TYP LINO. 10. SCREW SPACING SHALL NOT BE LESS THAN 3 TIMES THE NOMINAL SCREW DIAMETER. SCREWU. EDGE DISTANCE SHALL NOT BE LESS THAN 1.5 TIMES THE NOMINAL SCREW DIAMETER. PENETRATION OF SCREWS THROUGH JOINED MATERIALS SHALL NOT BE LESS THAN 3 EXPOSED Q THREADS. SCREW HEADS SHALL BE LOW -PROFILE TYPE. W J 11. SCREWS SHALL CONFORM WITH ASTM C1513 AND HAVE A CORROSION -RESISTANT COATING. J 0 12. BOLTS SHALL BE INSTALLED IN STANDARD SIZE HOLES, LINO. STANDARD SIZE HOLES SHALL BE BOLT U U DIA + 1/32" FOR BOLTS SMALLER THAN 1/2" DIA, AND BOLT DIA + 1/16" AT 1/2" DIA AND LARGER BOLTS. 13. WELDING SHALL CONFORM WITH AWS D1.3. WELDING TO STRUCTURAL STEEL SHALL ALSO U) CONFORM WITH AWS D1.1. THE ELECTRODES USED FOR WELDING SHALL HAVE A MINIMUM YIELD O J STRENGTH OF 60 KSI. WELDS OF GALVANIZED STEEL SHALL BE COATED WITH A ZINC -RICH PAINT. 14. FASTENING OF SHEATHING SHALL BE WITH SELF -DRILLING SELF -TAPPING SCREWS @ 12" OC MAX AT ALL BEARINGS. #6 MIN FOR GYPSUM BOARD & #8 MIN FOR STRUCTURAL PANELS. SCREW W HEADS SHALL BE COUNTER SUNK FLAT -PROFILE TYPE. 15. FRAME INDIVIDUAL MEMBERS AND EACH ELEMENT OF BUILT-UP MEMBERS, CONTINUOUS ONE W PIECE BETWEEN SUPPORTS. SPLICE ONLY WHERE SPECIFICALLY NOTED. zQ 16. PAF FASTENERS SHALL BE "HILTI" X-U (ICC ESR 2269), TYP LINO. INSTALLATION OF FASTENER SHALL BE IN ACCORDANCE WITH THE EVALUATION AGENCY REPORT. LINO, INSTALL FASTENERS WITH SUFFICIENT EDGE DISTANCE AND SPACING TO ACHIEVE FULL CAPACITY. DATE: xxxx 17. PAF FASTENERS TO CONCRETE SHALL HAVE 1" MIN EMBEDMENT INTO CONCRETE, TYP UNO. JOB NO.: SEA-21-011 18. PAF FASTENERS TO STRUCTURAL STEEL SHALL HAVE MIN EMBEDMENT TO STEEL PER MANUFACTURER, TYP LINO. A10.3 SCALE TYP CFSF WALL CONN AT BASE 1"=1'-0' 21 (1) SCREW AT EA JAMB STUD ES \V BUILT-UP SILL TYP CLG. HT. CFSF BRACING SCALE 16 TYP CFSF SILL CONN TO JAMBS SCALE 11 SCALE TYP CFSF SILLS