20-104814-Final PermitCity of Federal Way
Coiniounity Development Dept.
_ 3325 8th Ave S
Federal Way, WA 98003
Ph: (253) 835-2607 Fax: (253) 835-2609
Project Name: MITCHELL
Project Address: 3306 S 334TH ST
Building - Single Family
Permit #:20-104814-00-SF
Inspection Request Line: (253) 835-3050
Parcel Number: 614360 0266
Project Description: BLUEBEAM - Construction of a new 2,682 square foot 2-story single family residence with a
91 square foot covered entry, a 61 square foot deck and a 486 square foot attached garage.
Includes plumbing and mechanical. ***4 Bedrooms; $450000 Estimated Selling Price'
Owner
Applicant
Contractor
Lender
BRIAN MITCHELL
BRIAN MITCHELL
OWNER IS CONTRACTOR
OWNER IS LENDER
3815 S 380TH ST
3815 S 380TH ST
AUBURN WA 98001
AUBURN WA 98001
Census Category: 101 - New Single Family House
Includes:
#1 1
#2
#3
#4
Occupancy Class:
R-3
Construction Type:
Type V - B
Occupancy Load:
Floor Area (sq. ft.)
2.692.00
Additional Permit Information
New / Additional Sq. Feet - I st Floor .....................
1129
New / Additional Sq. Feet - 3rd Floor .....................
0
New / Additional Sq. Feet - Basement ....................
0
Occupancy #1 - Construction Type .........................
Type V - B
New / Additional Sq. Feet - Garage ........................
486.
Plumbing Work Valuation? .....................................
8000
Number of Stories......,..........,..... .
2
Plumbing to be Included? ........................................
Yes
Will Certificate of Occupancy be Issued? ...............
Yes
Comprehensive Plan Designation ........................... SF - High -Density
Residential
Total Valuation: 359,614.90
Ducting
Furnaces
Hot Water Tanks
Bathtubs
Lavatories
Water Closets
New / Additional Sq. Feet - 2nd Floor ....................
1563
Occupancy #I - Area (Sq. Feet) ..............................
2692
BasicPlan?...........................................................
No
New / Additional Sq. Feet - Deck ...........................
61
Mechanical to be Included? .....................................
Yes
Mechanical Work Valuation? ..................................
8000
New / Additional Sq. Feet - Other ..........................
91
New / Additional Sq. Feet - Total ...................
3330
Occupancy #1 - Use ...............
Residence (1 or 2
family)
Zoning Designation................................................I
RS 9.6
Mechanical Fixtures
I Fans
I Gas Piping
I
Plumbing Fixtures
2 Dishwashers
4 Showers
3 Hose Bibbs
CONDITIONS:
5 Fireplace Inserts 2
1 Gas Pipe Outlets 5
1 Laundry Washer Outlets 1
1 Sinks 2
2
Per FWRC Section 19.130.210(2) Single-family residential uses shall surface the first 40 feet of a
driveway. Per Public Works policy, that portion between the front property line and edge of roadway
shall be caved with asphalt.
PERMIT EXPIRES Sunday, 5 September, 2021
Permit Issued on Tuesday, March 9, 2021
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
Washington and the City of Federal Way.
Owner or agent: Date:
City of Federal Way
Certificate of [occupancy
This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section
R110 of the International Residential Code is certifying that at the time of issuance, this structure was in
compliance with the various ordinances of the City regulating building construction or use. This certificate is valid
ONLY when endorsed by City staff.
Tenant Name: MITCHELL
Address: 3306 S 334TH ST
Permit # 20-104814-00-SF
Includes: #1 42 #3 #4
Occupancy Class: R-3
Construction Type: Type V - B
Occupancy Load:
Floor Area (sq. ft.) 2,692.00
Owner Name: BRIAN MITCHELL.
Owner Address: 3815 S 380TH ST
AUBURN WA 98001
Building Official
Date
The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
experience has shown most severely affect the health and safety of the general public. Although the City has made as complete
a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees
nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every
ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon
which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises.
A�k
CITY OF
Federal Way
THIS CARD IS TO REMAIN ON -SITE
Construction Inspection Record
INSPECTION REQUESTS: (253) 835-3050
PERMIT #: 20 104814 00 Address: 3306 S 334TH ST
Project: BRIAN MITCHELL FEDERAL WAY WA 98003
Scheduled inspections maybe failed if this card is not on -site DO NOT 1.DSI- '1'111S CARD. Inspections are listed as close to sequential order as possible
(read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card.
❑ SWM Precon Site Mtg (4400) ❑ Initial Erosion Control (4365) ❑ Footings/Setback (4110)
Approved To be done PRIOR to breaking ground Approved to place concrete
By Date By Date By Date
❑ Foundation Wall (4115) ❑ Drainage/Downspout (4040) ❑ Plumbing Groundwork (4190)
Approved to place concrete Approved to backfill Approved to cover
By Date By Date By Date
El Slab/Concrete Floor (4255) ❑ Underfloor Framing (4285) Q Floor Sheathing (4105)
Approved to place concrete Approved to sheath floor Approved to install flooring
By Date By Date By Date
El
Shear Walls (4245)
El
Roof Sheathing (4220)
Rough Plumbing (4230)
Approved to install siding
Approved to install roofing
Approved
By
Date
By
Date
By
Date
Mechanical Rough -in (4165)
❑ Gas Piping (4125)
❑
Fire/Draft Stops (4095)
Approved
Approved to release test
Approved
By
Date
By
Date
By
Date
Interim Erosion Control (4370)
Approved
By Date
By
Gypsum Wallboard Nailing (4130)
Approved to install mud & tape
Date
❑
By
Final Erosion Control (4375)
Approved
Date
❑ Insulation (4150)
Approved to install wallboard
By Date
By
Final - Building (4050)
Approved
Ar-J 1)ate 9I ?j iho
Final - Mechanical (4065)
Approved
By Date
❑ Final - Plumbing (4075)
Approved
By Date
❑
Rough Electrical
❑
Final Electrical
Right of Way
Approved
Approved
Approved
By
Date
By
Date
By
Date