Loading...
22-101694City of Federal Way Community Development Dept. 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name: TWIN LAKES AFH Project Address: 3775 SW 319TH ST Building - Single Family Permit #:22-101694-00-SF Inspection Request Line: (253) 835-3050 Parcel Number: 873198 3120 Project Description: Verification of Occupancy for Adult Family Home. ***No construction work allowed under this permit.*** Owner Applicant Contractor_ Lender DEMEKE MECONNEN DEMEKE MECONNEN 3775 SW 319TH ST 3775 SW 319TH ST FEDERAL WAY WA 98023 FEDERAL WAY WA 98023 Census Category: 434 - Residential alt/add - no change in number of units Includes: # 1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load: Floor Area (sq. ft.) Additional Permit Information Mechanical to be Included? ..................................... No Is this an Online or O.T.C. application?.................. Yes Plumbing to be Included? ........................ I............... No N❑ Fixtures Associated With This Permit II PERMIT EXPIRES Wednesday, 12 October, 2022 Permit Issued on Friday, April 15, 2022 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Was.hington and the City of Federal Way. F I r Owner or agent: Date: Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 218 IRC Section R330 (WAC 51-51) APPLICATION NUMBER: SECTIONS 1.2. 3. AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION WILL BE PROCESSED SITEADDRESS:,3��� �� ASSESSOR'S TAX/PARCEL#:_ PROPERTY OWNER NAME: DAYTIME PHONE AFH LICENSEE NAME (IF DIFFERENT): i DAYTIME SECTION••' PLAN On a separate sheet of paper (8 1I2x 11) draw a floor plan (including all floors) of your prospective AN. Include all sleeping rooms (bedrooms) indicating which bedroom is: A, B, C D, E and F. Label all components for exiting i.e., stairs, ramps, platforms, lifts and elevators. I certify under penalty of perjury that the information Furnished by me Is true and correct to the best of my knowledge, and that I am requesting or I am authorized by the owner of tho above promises to request inspection roi the operation of an Adult Family Home at thrS location, I agree to hold harmless the jurisdiction conducting such inspections, at my request, as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation of such claim), which may be made by any person, including the undersigned, and filed against the jurisdiction, but only where such claim arises out of the reliance of the jurisdiction, Including its officers and employees, upon the accuracy of the information supplied to the jurisdiction as a part of this application, NAME/TITLE: DATE: PROPERTY OWNER 13APPLICANT Q LICENSEE Implementation Date: 2021 February 01 Updated: 2021 February (Ettective Feb. 1, 2021 WAC 51-51-0330 Section R330 — Adult family homes. SECTION R330 ADULT FAMILY HOMES R330.1 General. This section shall apply to all newly constructed adult family homes and all existing single family homes being converted to adult family homes. This section shall not apply to those adult family homes licensed by the state of Washington department of social and health services prior to July 1, 2001. R330.2 Reserved. R330.3 Sleeping room classification. Each sleeping room in an adult family home shall be classified as: 1. Type S - Where the means of egress contains stairs, elevators or platform lifts. 2. Type NS1 - Where one means of egress is at grade level or a ramp constructed in accordance with R330.9 is provided. 3. Type NS2 - Where two means of egress are at grade level or ramps constructed in accordance with R330.9 are provided. R330.4 Types of locking devices and door activation. Ali bedroom and bathroom doors shall be openable from the outside when locked. Every closet shall be readily openable from the inside. Operable parts of door handles, palls, latches, locks and other devices installed in adult family homes shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. Pocket doors shall have graspable hardware available when in the closed or open position, The force required to activate operable parts shall be 5.0 pounds (22.2 N) maximum. Required exit doors shall have no additional locking devices. Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing reentry into the adult family home without the use of a key, tool or special knowledge. R330.5 Smoke and carbon monoxide alarm requirements. All adult family homes shall be equipped with smoke and carbon monoxide alarms installed as required in Sections R314 and R315.1. AParms shall be installed in such a manner so that the detection device warning is audible from all areas of the dwelling upon activation of a single alarm. R330.6 Escape windows and doors. Every sleeping room shall be provided with emergency escape and rescue windows as required by Section R310. No alternatives to the sill height such as steps, raised platforms or other devices placed by the openings will be approved as meeting this requirement. R330.7 Fire apparatus access roads and water supply for fire protection. Adult family homes shall be served by fire apparatus access roads and water supplies meeting the requirements of the local jurisdiction. R330.8 Grab bar general requirements. Where facilities are designated for use by adult family home clients, grab bars for water closets, bathtubs and shower stalls shall be installed according to this section. R330.8.1 Grab bar cross section. Grab bars with a circular cross section shall have an outside diameter of 1 1/4 inches minimum and 2 inches maximum. Grab bars whh noncircutar cross section shall have a cross section dimension of 2 inches maximum and a perimeter dimension of 4 inches minimum and 4 5/8 inches maximum. R330.8.2 Grab bar installation. Grab bars shall have a spacing of 1 1/2 inches between the wall and the bar. Projecting objects, control valves and bathtub or shower stall enclosure features above, below and at the ends of the grab bar shall have a clear space of 1 1/2 inches to the grab bar. EXCEPTION: Swing -up grab bars shall not be required to meet the 1 1/2 inch spacing requirement. Grabs bars shall have a structural strength of 250 pounds applied at any point on the grab bar, fastener, mounting device or supporting structural member. Grab bars shall not be supported directly by any residential grade fiberglass bathing or showering unit. Acrylic bars found in bathing units shall be removed. Fixed position grab bars, when mounted, shall not rotate, spin or move and have a graspable surface finish R330.8.3 Grab bars at water closets. Water closets shall have grab bars mounted on both sides. Grab bars can be a combination of fixed position and swing -up bars. Grab bars shall meet the requirements of R330.8. Grab bars shall mount between 33 inches and 36 inches above floor grade. Centerline distance between grab bars, regardless of type used. shall be between 25 inches minimum and 30 inches maximum. Implementation Date: 2021 February 01 Updated: 2021 February R337.8.3.1 Fixed position grab bars. Fixed position grab bars shall be a minimum of 36 inches in length and start 12 inches from the rear wall. R330.8.3.2 Swing -up grab bars. Swing -up grab bars shall be a minimum of 28 inches in length from the rear wall. R330.8.4 Grab bars at bathtubs. Horizontal and vertical grab bars shall meet the requirements of R330.8. R330.8.4.1 Vertical grab bars. Vertical grab bars shall be a minimum of 18 inches long and installed at the control end wall and head end wall. Grab bars shall mount within 4 inches of the exterior of the bath tub edge or within 4 inches within the bath tub. The bottom end of the bar shall start between 36 inches and 42 inches above floor grade. EXCEPTION: The required vertical grab bar can be substituted with a floor to ceiling grab bar meeting the requirements of R330.8 at the control end and head end entry points. R330.8.4.2 Horizontal grab bars. Horizontal grab bars shall be provided at the control end, head end, and the back wall within the bathtub area. Grab bars shalt be mounted between 33 inches and 36 inches above floor grade, Control end and head end grab bars shall be 24 inches minimum in length. Back wall grab bar shall be 36 inches minimum in length. R330.8.5 Grab bars at shower stalls. Where shower stalls are provided to meet the requirements for bathing facilities, grab bars shall meet the requirements of R330.8. EXCEPTION: Shower stalls with permanent built-in seats are not required to have vertical or horizontal grab bars at the seat end wall. A vertical floor to ceiling grab bar shall be installed within 4 inches of the exterior of the shower aligned with the nose of the built-in seat. R330.8.5.1 Vertical grab bars. Vertical grab bars shall be 18 inches minimum in length and installed at the control end wall and head end wall. Vertical bars shall be mounted within 4 inches of the exterior of the shower stall or within 4 inches inside the shower stall. The bottom end of vertical bars mount between 36 inches and 42 inches above floor grade. R330.8.5.2 Horizontal grab bars. Horizontal grab bars shall be installed on all sides of the shower stall mounted between 33 inches and 36 inches above the floor grade. Horizontal grab bars shall be a maximum of 6 inches from adjacent walls. Horizontal grab bars shall not Interfere with shower control valves. R330.9 Ramps. All interior and exterior ramps, when provided, shall be constructed in accordance with Section R311.8 with a maximum slope of 1 vertical to 12 horizontal. The exception to R311.8.1 is not allowed for adult family homes, Handrails shall be installed in accordance with R330.9.1. R330.9.1 Handrails for ramps. Handrails shall be installed on both sides of ramps between the slope of 1 vertical to 12 horizontal and 1 vertical and 20 horizontal in accordance with R311.8.3.1 through R311.8.3.3. R330.10 Stair treads and risers. Stair treads and risers shall be constructed in accordance with R311.7.5. Handrails shall be installed in accordance with R330.10.1. R330.10.1 Handrails for treads and risers. Handrails shall be installed on both sides of treads and risers numbering from one riser to multiple risers. Handrails shall be installed in accordance with R311.7.8.1 through R311.7.8.4 R330.11 Shower stalls. Where provided to meet the requirements for bathing facilities, the minimum size of shower stalls for an adult family home shall be 30 inches deep by 48 inches long, (Statutory Authority: RCW 19,27.931 and chapters 19.27 and 34.05 RCW. 1 M4-068, § 51-51-0325, filed 2)1/13, effective 7/1113. Statutory Authority: Chapter 19,27 RCW. 10-16-036, § 51-51-0325, filed 8125/10, effective 9/25110. Statutory Authority: RCW -q 27.19�, 19.27.020, and chapters 19.27 and gLQ0 RCW. 09-04-023, § 51-51-0325, filed 1/27/09, effective 711110. Statutory Authority: RCW 1J 2� 19 2_ and chapters 19.27 and 34, 5 RCW. 07-01-090, § 51-51-0325, filed 12119106, effective 711107. Statutory Authority: RM 19.27.031 and 19 2� 7.07?t. 04- 01-109, § 51-51.0325, filed 12117103, effective 711104.]iStatutoryAuthority! RCW 19.27.031 and1�27.O 4. WSR20-03-023, § 51-51-0330, filed 116120, effective 711120.] Implementation Date: 2021 February 01 Updated: 2021 February SECTION 5 MUST BE COMPLETED BY THE BUILDING DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED. PLEASE CHECK ALL APPLICABLE BOXES; MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN — USING THEIR PROSPECTIVE RESIDENT BEDROOM DESIGNATIONS OF A 8 CD SAND FAND CLASSIFICATION CODE S, NS1 OR NS2. R330.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: Type S - where the means of egress contains stairs, elevators or platform lifts to evacuate residents to public area. Type NS1— where 1 means of egress at grade level (has no stairs) or ramp constructed compliant with R330.9 is provided to evacuate residents to public area. Type NS2 —where 2 means of egress at grade level (both have no stairs) or ramps constructed compliant with R330.9 are provided to evacuate residents to public area. SLEEPING ROOM A ©Type S Type NSi Type NS2 YES NO Closet door/s are readily openable from the inside Yes 0 No ON/A Smoke alarm is installed in the bedroom O Bedroom door opens easily and quickly from the outside when locked O Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF 13 Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed E] SLEEPING ROOM B 113 Type S Type NS1 O Type NS2 Y S NO Closet door/s are readily openable from the inside III Yes O No ON/A I Smoke alarm is installed in the bedroom 0 droom door opens easily and quickly from the outside when locked 13 eping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) r d EPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SFeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed O SLEEPING ROOM C OType NS2 Y 5 NO Closet door/s are readily openable from the inside Yes O No is installed in the bedroom %�� O Bedroom door opens easily and quick!y from the outside when locked O Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) 0 O EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed [] SLEEPING ROOM D Type S Type NS1 OType NS2 Closet dooms are readily operable from the inside Yes O No ON/A Smoke alarm is installed in the bedroom YES NO 13 Bedroom door opens easi[ and quickly from the outside when locked Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at lease 20" wide) EXCEPT O per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF Slee ing room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed O SLEEPING ROOM E ©Type S pe NS1 ]Type NS2 Y NO Closet door/s are readily openable from the inside Yes [� No L]N/A Smoke alarm is installed in the bedroom Bedroom door opens Basil and quickly from the outside when locked O 1 Sleeping room window has a n .t opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) EXCEPT O per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed O Type LI Type NS2 SLEEPING ROOM F 0 Type S T �rm�i Closet doOrf S are readil opena%le from the inside Yes ©No ON/A smoke installed inthe bedroom YES NO O I Bedroom door opens easily and quickly from the outside when locked O [f Sleeping room window has a ne,: opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) EXCEPT O per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF 51ee ing room window has a maximum sill hei ht of 44" above floor to clear opening; no ste s unc er window allowed 0 ID Implementati0n Date: 2021 February 01 Updated: 2021 February UtIMMAL — YES NO Bathroom doors are easily and quickly openable from the outside when locked M 13 Carbon Monoxide alarms are installed as required in R315 on each level of the home. 0 Smoke alarms are installed on all levels of the dwelling, in each resident sleeping room, outside each separate sleeping area in the immediate vicinity of sleeping rooms (13314). E3 Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all parts of the dwelling upon activation of a single device. ED 13 Access road and water supply meet local fire jurisdictional requirements. 0 R330.4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist (lever -type). 10 0 Pocket doors shall have graspable hardware available when in the closed or open position. AT 13 .8 Ramp e Ramp N/A . I F YES [3 NO ❑.8.1 Maximum Slope one unit vertical in twelve units horizontal (8.3% slope). (Exception R311.8.1 Not allowed in © 0.9) R311.8.2 Landing Requirements: min. 3X3 foot landing at top/bottom, where doors open onto ramps, and where ramp changes directions. 0 0 R330.9.1 Handrails required on both sides of ramp. 0 Outside Ramp I N/A [3 R311.8.1 Maximum Slope one unit vertical in twelve units horizontal (8.3% slope). (Exception R3'.1.8.1 Not allowed in YES ,P NO 0 R330.9) R311.8.2 Landing Requirements: min. 3X3 foot landing attop/bottom, where doors open onto rslmps, and where ramp changes directions. M 0 R330.9.1 Handrails required on both sides of ramp, R312.1.1 Guards shall be located along open -sided walking surfaces, that are located more than 30 inches measured 0 vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the open side. Guards below are depicted vertically as an example only. Guard 36" min Handrail both sides Less than 4" 34" - 38" 3'x3'min 3' x 3' min I landing landing 3' One unit vertical in twelve units horizontal I minimum is an 8.3% slope all along surface of the ram r3 p• �' minimum Implementati-)n Date: 2021 February 01 Updated: 2021 February R311.2 Means of Egress YES NO R311.2 Door must be side -hinged with min. width of 32 inches between face of door and stop. Height n r less than 78 inches. R330.4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist (i.,ver-type). EP 0 R330.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry 13 without use of key, tool or special knowledge. R311.7 Stairways I N/AU I YES NO R311.7.5.1 Riser Height: Max riser height shall be 7 % inches (8 inches in structures built prior to July 1, 2004 Ja R311.7.5.2 Tread Depth: Min. tread depth shall be in 10 inches (9 inches in structures built prior to July 1,:2004) —EL R330.10,1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering1rom one riserto multiple risers. Handrailssha11 be installed in accordance_ with R311.7.8.1—R311.7.8.4__ R330.8 Grab Bars in Bathrooms N/A YES NO Grab bars shall be installed for all water closets (toilets), bathtubs and showers according to R330.8. Water Closets (toilet) shall have grab bars installed on both sides according to R330.8.3 Bathtubs shall have two vertical and three horizontal grab bars installed according to R330.8.4 Shower stalls have two vertical and horizontal grab bars mounted on all sides of shower according to R330.8.5 Shower stalls must be minimum size of 30 inches deep by 48 inches long (R330.11) PASSED NAME OF AFH: 7 5 Adult Family Home Project Address BUILDING DEPT. BUILDING (PRINT) INSPECTOR'S SIGNATURE BUILDING DEPT. OFFICE ADDRESS a.l t'1)A v1 otgCO3 L4 DATE: �� 5 2CR3� ,lam f�j OFFICE PHQNE NUMBER: I Application and inspection checklist developed by Washington Association of Building officials (WABO), in cooperation •kith Department of Social and Health Services (DSHS) for use by Moth departments and licensors in accordance with WAC 388-7&10700. Implementation Date: 2021 February 01 Updated: 2021 February m 0 VYOO�I,(139 * H 0 AAOPUIM 3 VYOOI�J(138 6 J VYMJ(139 mopulm m woo =r K —j 0 3 0 0 CL OD 00 0 [Fill I =====* � > Aem PH =r 0:) -00 gin; CL '� n� 0 X z z G) X 97d ex 0 0 1 0 0 CD CL o 0 D E:;; punel L UOPIN O A8M IIBH mopulm o'� PX3 JOOCI UIeVV 96ejols mopulm JOO(] Aeon -3AIJC]- CD CD CD CD 0) RFC IV 4;%� �7 PERMIT APPLICATION CIYY of �. . ;�„� � S�R 22 f+'�l CITY F FEDE P IT CENTER + 33325 8th Avenue South + Federal Way, WA 98003-6325 Federal Way �s i�!<j�(W�.C� o M 3- 35-2607 + FAX 253-835-2609 + perinitcenter@cityoffederadwayr.Coln jENT PERMIT NUMBER _ Irk❑ TARGET DATE SITE ADDRESS SUITE/UNIT i1 W i f PROD CT VALUATION ZONING ASSESSOR'S TAX/PARCEL N LeL7 O �0A. _S_ qL_- -'&- _V '�_ 2- - —'A- L 00—L 42 TYPE OF PERMIT $UII DING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT PROJECT DESCRIPTION Detailed descrcp n of work to �. be included on this permit only NAME PRIMARY PHONE PROPERTY OWNER MAILING ADDRESS - - r W E-MAIL CITY STAM ZIP N PHONE MAILING ADDRESS E-MAIL CONTRACTOR CITY STATE ZIP FAX WA STATE CONTRACTOR'S LICENSE Y EXPIRATION DATE UBI Y I I _ NAME PRIbURY PHONE APPLICANT CaING ADnR-P-95 r 1EKAIL CITY STATE ZIP tV m AX L4 F rneco Y1m; , r: - � PHONE � PROJECT CONTACT �.� MAILING 1 ` OPES Lt.) E-MAM (The individual to receive and respond to all correspondence CITY STATE 1� ZIP FAX concerning this application) PROJECT FINANCING Aht£ ❑ OWNER -FINANCED When value is $5,000 or more (RCW 19.27.095) MAMUM ADDRERS, CITY, RTATE. 872- PHONE I certify ureter penalty of perjury that I am the property owner or authorized agent of the property owner. I cert(fy that to the best Of 7,9 knowledge, the in, formation submitted in support of this permit application is true and correct. I certify that I will comply with ail applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the Issuance of this permit does not remote the owner's respon.sthility for compliance with local, state, or federal laws regulating construction or environmental Inws. I further agree La hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only inhere such claim arises out of eiiance of the city, including its officers and employees, upon the Accuracy of the information supplied to the city as a part f this a lication. SIGNATURE: DATE 1�11 I PRINT NAME: YL L�l L w Bulletin #100 —February 19, 2020 Page 1 of k.\HandoutslPermit Annliratinn VALUE OF MECHANICAL WORK MECHANTWAL PERMIT $ Indicate how markly of each type of Lrture to be installed or relocated as art o flits ro eCt Ito itvi include exi5 ' Itlt xres to remain AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER (Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS (comm,w) BOILERS FURNACES HOT WATER TANKS (Gas) COMPRESSORS GAS LOG SETS REFRIGERATION.SYST DUCTING GAS PIPING WOODSTOVES VALUE OF PLUMBING WORK PLUMBING PERMIT _ Indicate how many of each type orffxture to be installed or relocated as partqf this pLojoct. Do rwt include'e)ds ' res to remain. BATI1T0BS jorTub/Snow Combo) LAVS (Hand Sinks) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS (Kimhen/U0ty) WATER HEATERS (Eiectric) HOSE BIBBS SUMPS a WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOO11 ' SEWER PtrkZ =dR - VALUE OF ER[STEM. %V90VS =nS ' AA9■ LA*e, M ew--t $ Z) F.MSMGIPREVIOUS USE LOT SIZE (In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? ❑ Yes je No ❑ Yes r/ No RESIDENTIAL - NEW OR ADDITi6N' ` ` AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL FOR OFFICE TISE BASEMENT FIRST FLOOR (or Mobile Home) SECOND FLOOR COVERED ENTRY DECK GARAGE J2' CARPORT ❑ OTHER (descrfbe) r �_.. AreaTotals FMBTMG MOPMD razwi •_....W...._ _.._�.._. _.,._ ,.�...... "'NEW 1rT(iliiF,t9'O:NLiR" r I;S'I'IMATED SELLING PRICE $ # OF 13EDROOMS COMMERCIAL - NEW/ADDITION AREA DESCRIPTION Area in Square Feet Occupancy Group(s) Construction a # of Storles- Additional Information NzW BUILDING ADDITION COMMERCIAL - REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area in S uam Feet Occupancy Group(s) Construction a # of Stories Additional Information TOTAL BUILDING TENANT AREA ONLY PROJECT AREA ONLY Bulletin #100 —February 19, 2020 Page 2 of 2 k:\Handouts\Permit Application