Loading...
22-102749-UP-Clearing & Grading Plan-06-15-2022-V1fill FOA 1.9 W, GRAPHIC SCALE 50 0 25 50 100 IN FEES' ) 1 inch = 50 ft. VERTICAL DATUM: NGVD 29 Al FOUND MONUMENT AS NOTED f� CALCULATED MONUMENT AS NOTED (C) CALCULATED DIMENSION (M) MEASURED DIMENSION (Rx) RECORD DOCUMENT (PER REFERENCE) TPN TAX PARCEL NUMBER BOUNDARY LINE — -- - _- — - - ADJOINER PROPERTY BOUNDARY RIGHT OF WAY LINE ROAD CENTERLINE _ — -- - — EASEMENT LINE ............... SHORT PLAT LINE --- -- �-- SECTION LINE AREA COVERED BY CONTAINERS *1 GATE POST - a —�- 6' CHAIN LINK FENCE WROUGHT IRON FENCE MINOR CONTOUR MAJOR CONTOUR x 0..{ 0 SANITARY SEWER STUB SPOT ELEVATION SANITARY SEINER MANHOLE SANITARY SEINER CLEANOUT STORM MANHOLE 71 STORM CATCH BASIN { STORM CULVERT - SD --- SO -- SO - - BURIED STORM DRAIN LINE STORM DITCH LINE BURIED SANITARY SEWER LINE IE INVERT ELEVATION PVC PLAS ll PIPE D! DUCTILE IRON PIPE RCP REINFORCED CONCRETE PIPE _Q_ UTILITY POLE P POWER VAULT POWER METER [� JUNCTION BOX TRANSFORMER LIGHT POLE -¢ LIGHT POLE WITH ARM GAS VALVE Q CABLE VAULT Q TELEPHONE RISER M WATER VALVE ED WATER METER 0 IRRIGATION CONTROL VALVE 0 UNKNOWN UTILITY MANHOLE FYI UNKNOWN UTILITY VAULT —:THE ----.'0HE— OVERHEAD POWER LINE --OHT-.----,.._ �..�,....._....._. OVERHEAD TELEPHONE LINE BURIED GAS LINE ASPHALT SURFACE CONCRETE SURFACE l... GRAVEL SURFACE U E 0 .. SOUTH .. TOWNSHIP FEDERALCITY OF O. OWNER 35000 PACIFIC HWY SOUTH, LLC P.O. BOX 94176 SEATTLE, WA 98124--6476 PHONE: (253) 826-5020 EINGINE'ER/SURVEYOR APEX ENGINEERING, LLC 2601 SOUTH 35TH, SUITE 200 TACOMA, WA 98409 PHONE': (253) 473-4494 1. COVER SHEET 2. GRADING AND TESC PLAN 3. TESC NOTES AND DETAILS 4. STORM PLAN 5. STORM PROFILES AND DETAILS 6. STORM PROFILES 7. STORM PROFILES 8. STORM NOTES AND DETAILS 9. 351ST STREET EAST PLAN AND PROFILE 10. 351ST STREET EAST GRADING DETAILS 11. PACIFIC HWY SOUTH IMPROVEMENTS 1'J Pnnn Akin CTnRI<I nI-TAII S 343RD ST PARK N RID£ S 344TH ST cc cc S 347TH ST S 348TH ST PARK N RIDE "' w Q S 35 ND ST SCALE: NTS P"N NOTES `EY 1. LOCATIONS OF OFFSITE BUILDINGS AND DRIVEWAYS FOR SURROUNDING AREA WERE OBTAINED FROM AERIAL MAPPING AND ARE APPROXIMATE ONLY. 6QVND.ARY/T' PHY SEE SHEET 14 OF 14 FOR BOUNDARY AND TOPOGRAPHIC INFORMATION 2. ADJACENT PROPERTY LINES WERE OBTAINED FROM PUBLIC SOURCES AND ARE APPROXIMATE ONLY. TAX PARCEL NUMBERS WERE OBTAINED FROM KING COUNTY WESSITE. 3. TO SCHEDULE A PRECONSTRUCTION MEETING OR INSPECTION CONTACT THE CITY'S PUBLIC WORKS DEPARTMENT PRECONSTRUCTION%INSPECTION NOTIFICATION PHONE NUMBER (253) 835-2700. 1 SITE AREA : 182,722 # SF. ( 4.2 ± ACRES ) PARCEL NUMBERS : 202104-9043, 202104-9155, 202104-9162, 202104-9163 ZONING : CE ( COMMERCIAL ENTERPRISE ) ON -SITE PAVING AND CURB : 163,025 f SF. RIGHT OF WAY DEDICATION : 0 SF. CRITICAL AREAS : 0 SF. TRACT AREAS : 0 SF. OWNER/DEVELOPER: 35000 PACIFIC HWY SOUTH, LLC SI M ADDRESS 35000 PACIFIC HWY S FEDERAL WAY, WA 98003 L.1Gl ''1L L�ilES�rR T ION LOTS 1, 2, 3 AND 4, KING COUNTY SHORT PLAT NUMBER 274023, RECORDED UNDER RECORDING NUMBER 8011050835, IN KING COUNTY, WASHINGTON; TOGETHER WITH THAT PORTION OF VACATED STATE HIGHWAY ADJOINING SAID LOTS 3 AND 4, AS RECORDED UNDER RECORDING NUMBERS 8212060518 AND 8212060520, AND CORRECTED UNDER RECORDING NUMBERS 8307070635 AND 8307070636. EXCEPT THOSE PORTIONS CONVEYED TO THE CITY OF FEDERAL WAY BY INSTRUMENTS RECORDED UNDER RECORDING NUMBERS 201601080001121 20160108000113 AND 20160108000115. CUT = 5,050 C.Y. FILL = 1,450 C.Y. NET = 3,600 C.Y. (CUT) NOTE: QUANTITIES CALCULATED FROM EXISTING GRADE TO FINISH GRADE WITH ROAD SECTION TO SUBGRADE NOT REMOVED. STRIPPING OR SOIL SUITABILITY NOT INCLUDED. NOTE: THE ABOVE QUANTITIES ARE ESTIMATES ONLY, THEY ARE INTENDED FOR THE PERMITTING PROCESS. 00 NOT USE FOR BID PURPOSES. Know what's below. Call before you dig. NOTE: THIS APPROVAL. IS VOID I (ONE) YEAR AFTER APPROVAL DATE, THE CITY WILL. NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX—XXXXXX—XX APPROVED DATE -- z W 0 oll Q r- 0) (n4-t OD . ■,rr to C: Lo i) 0 04 C Cp < 0 �\ E '4t 0 U I 1 z ® 4 Nto 0 3 M U CO(04U9 Uj �0 ��` z v 0 u., -...� CL 49 W z J W J 0 DATE SEALED' -- �. JEL�� �11)�0F W A S,y�SO 40382 <v� s/ONAL���\ PROJECT MMAGIER COLLEEN HMM DESIIQV a) DRAVVN SA.J CHECKED GJ SEC T 2flo6 R 4E FILE NO DATE NAM= SCALE AS NOTED SHEET L ®E Lao 9LE NO 35072 0 APEX ENGINEERING LLC �2022 SPOT ELEVATION SANITARY SEINER MANHOLE SANITARY SEINER CLEANOUT STORM MANHOLE 71 STORM CATCH BASIN { STORM CULVERT - SD --- SO -- SO - - BURIED STORM DRAIN LINE STORM DITCH LINE BURIED SANITARY SEWER LINE IE INVERT ELEVATION PVC PLAS ll PIPE D! DUCTILE IRON PIPE RCP REINFORCED CONCRETE PIPE _Q_ UTILITY POLE P POWER VAULT POWER METER [� JUNCTION BOX TRANSFORMER LIGHT POLE -¢ LIGHT POLE WITH ARM GAS VALVE Q CABLE VAULT Q TELEPHONE RISER M WATER VALVE ED WATER METER 0 IRRIGATION CONTROL VALVE 0 UNKNOWN UTILITY MANHOLE FYI UNKNOWN UTILITY VAULT —:THE ----.'0HE— OVERHEAD POWER LINE --OHT-.----,.._ �..�,....._....._. OVERHEAD TELEPHONE LINE BURIED GAS LINE ASPHALT SURFACE CONCRETE SURFACE l... GRAVEL SURFACE U E 0 .. SOUTH .. TOWNSHIP FEDERALCITY OF O. OWNER 35000 PACIFIC HWY SOUTH, LLC P.O. BOX 94176 SEATTLE, WA 98124--6476 PHONE: (253) 826-5020 EINGINE'ER/SURVEYOR APEX ENGINEERING, LLC 2601 SOUTH 35TH, SUITE 200 TACOMA, WA 98409 PHONE': (253) 473-4494 1. COVER SHEET 2. GRADING AND TESC PLAN 3. TESC NOTES AND DETAILS 4. STORM PLAN 5. STORM PROFILES AND DETAILS 6. STORM PROFILES 7. STORM PROFILES 8. STORM NOTES AND DETAILS 9. 351ST STREET EAST PLAN AND PROFILE 10. 351ST STREET EAST GRADING DETAILS 11. PACIFIC HWY SOUTH IMPROVEMENTS 1'J Pnnn Akin CTnRI<I nI-TAII S 343RD ST PARK N RID£ S 344TH ST cc cc S 347TH ST S 348TH ST PARK N RIDE "' w Q S 35 ND ST SCALE: NTS P"N NOTES `EY 1. LOCATIONS OF OFFSITE BUILDINGS AND DRIVEWAYS FOR SURROUNDING AREA WERE OBTAINED FROM AERIAL MAPPING AND ARE APPROXIMATE ONLY. 6QVND.ARY/T' PHY SEE SHEET 14 OF 14 FOR BOUNDARY AND TOPOGRAPHIC INFORMATION 2. ADJACENT PROPERTY LINES WERE OBTAINED FROM PUBLIC SOURCES AND ARE APPROXIMATE ONLY. TAX PARCEL NUMBERS WERE OBTAINED FROM KING COUNTY WESSITE. 3. TO SCHEDULE A PRECONSTRUCTION MEETING OR INSPECTION CONTACT THE CITY'S PUBLIC WORKS DEPARTMENT PRECONSTRUCTION%INSPECTION NOTIFICATION PHONE NUMBER (253) 835-2700. 1 SITE AREA : 182,722 # SF. ( 4.2 ± ACRES ) PARCEL NUMBERS : 202104-9043, 202104-9155, 202104-9162, 202104-9163 ZONING : CE ( COMMERCIAL ENTERPRISE ) ON -SITE PAVING AND CURB : 163,025 f SF. RIGHT OF WAY DEDICATION : 0 SF. CRITICAL AREAS : 0 SF. TRACT AREAS : 0 SF. OWNER/DEVELOPER: 35000 PACIFIC HWY SOUTH, LLC SI M ADDRESS 35000 PACIFIC HWY S FEDERAL WAY, WA 98003 L.1Gl ''1L L�ilES�rR T ION LOTS 1, 2, 3 AND 4, KING COUNTY SHORT PLAT NUMBER 274023, RECORDED UNDER RECORDING NUMBER 8011050835, IN KING COUNTY, WASHINGTON; TOGETHER WITH THAT PORTION OF VACATED STATE HIGHWAY ADJOINING SAID LOTS 3 AND 4, AS RECORDED UNDER RECORDING NUMBERS 8212060518 AND 8212060520, AND CORRECTED UNDER RECORDING NUMBERS 8307070635 AND 8307070636. EXCEPT THOSE PORTIONS CONVEYED TO THE CITY OF FEDERAL WAY BY INSTRUMENTS RECORDED UNDER RECORDING NUMBERS 201601080001121 20160108000113 AND 20160108000115. CUT = 5,050 C.Y. FILL = 1,450 C.Y. NET = 3,600 C.Y. (CUT) NOTE: QUANTITIES CALCULATED FROM EXISTING GRADE TO FINISH GRADE WITH ROAD SECTION TO SUBGRADE NOT REMOVED. STRIPPING OR SOIL SUITABILITY NOT INCLUDED. NOTE: THE ABOVE QUANTITIES ARE ESTIMATES ONLY, THEY ARE INTENDED FOR THE PERMITTING PROCESS. 00 NOT USE FOR BID PURPOSES. Know what's below. Call before you dig. NOTE: THIS APPROVAL. IS VOID I (ONE) YEAR AFTER APPROVAL DATE, THE CITY WILL. NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX—XXXXXX—XX APPROVED DATE -- z W 0 oll Q r- 0) (n4-t OD . ■,rr to C: Lo i) 0 04 C Cp < 0 �\ E '4t 0 U I 1 z ® 4 Nto 0 3 M U CO(04U9 Uj �0 ��` z v 0 u., -...� CL 49 W z J W J 0 DATE SEALED' -- �. JEL�� �11)�0F W A S,y�SO 40382 <v� s/ONAL���\ PROJECT MMAGIER COLLEEN HMM DESIIQV a) DRAVVN SA.J CHECKED GJ SEC T 2flo6 R 4E FILE NO DATE NAM= SCALE AS NOTED SHEET L ®E Lao 9LE NO 35072 0 APEX ENGINEERING LLC �2022 BURIED SANITARY SEWER LINE IE INVERT ELEVATION PVC PLAS ll PIPE D! DUCTILE IRON PIPE RCP REINFORCED CONCRETE PIPE _Q_ UTILITY POLE P POWER VAULT POWER METER [� JUNCTION BOX TRANSFORMER LIGHT POLE -¢ LIGHT POLE WITH ARM GAS VALVE Q CABLE VAULT Q TELEPHONE RISER M WATER VALVE ED WATER METER 0 IRRIGATION CONTROL VALVE 0 UNKNOWN UTILITY MANHOLE FYI UNKNOWN UTILITY VAULT —:THE ----.'0HE— OVERHEAD POWER LINE --OHT-.----,.._ �..�,....._....._. OVERHEAD TELEPHONE LINE BURIED GAS LINE ASPHALT SURFACE CONCRETE SURFACE l... GRAVEL SURFACE U E 0 .. SOUTH .. TOWNSHIP FEDERALCITY OF O. OWNER 35000 PACIFIC HWY SOUTH, LLC P.O. BOX 94176 SEATTLE, WA 98124--6476 PHONE: (253) 826-5020 EINGINE'ER/SURVEYOR APEX ENGINEERING, LLC 2601 SOUTH 35TH, SUITE 200 TACOMA, WA 98409 PHONE': (253) 473-4494 1. COVER SHEET 2. GRADING AND TESC PLAN 3. TESC NOTES AND DETAILS 4. STORM PLAN 5. STORM PROFILES AND DETAILS 6. STORM PROFILES 7. STORM PROFILES 8. STORM NOTES AND DETAILS 9. 351ST STREET EAST PLAN AND PROFILE 10. 351ST STREET EAST GRADING DETAILS 11. PACIFIC HWY SOUTH IMPROVEMENTS 1'J Pnnn Akin CTnRI<I nI-TAII S 343RD ST PARK N RID£ S 344TH ST cc cc S 347TH ST S 348TH ST PARK N RIDE "' w Q S 35 ND ST SCALE: NTS P"N NOTES `EY 1. LOCATIONS OF OFFSITE BUILDINGS AND DRIVEWAYS FOR SURROUNDING AREA WERE OBTAINED FROM AERIAL MAPPING AND ARE APPROXIMATE ONLY. 6QVND.ARY/T' PHY SEE SHEET 14 OF 14 FOR BOUNDARY AND TOPOGRAPHIC INFORMATION 2. ADJACENT PROPERTY LINES WERE OBTAINED FROM PUBLIC SOURCES AND ARE APPROXIMATE ONLY. TAX PARCEL NUMBERS WERE OBTAINED FROM KING COUNTY WESSITE. 3. TO SCHEDULE A PRECONSTRUCTION MEETING OR INSPECTION CONTACT THE CITY'S PUBLIC WORKS DEPARTMENT PRECONSTRUCTION%INSPECTION NOTIFICATION PHONE NUMBER (253) 835-2700. 1 SITE AREA : 182,722 # SF. ( 4.2 ± ACRES ) PARCEL NUMBERS : 202104-9043, 202104-9155, 202104-9162, 202104-9163 ZONING : CE ( COMMERCIAL ENTERPRISE ) ON -SITE PAVING AND CURB : 163,025 f SF. RIGHT OF WAY DEDICATION : 0 SF. CRITICAL AREAS : 0 SF. TRACT AREAS : 0 SF. OWNER/DEVELOPER: 35000 PACIFIC HWY SOUTH, LLC SI M ADDRESS 35000 PACIFIC HWY S FEDERAL WAY, WA 98003 L.1Gl ''1L L�ilES�rR T ION LOTS 1, 2, 3 AND 4, KING COUNTY SHORT PLAT NUMBER 274023, RECORDED UNDER RECORDING NUMBER 8011050835, IN KING COUNTY, WASHINGTON; TOGETHER WITH THAT PORTION OF VACATED STATE HIGHWAY ADJOINING SAID LOTS 3 AND 4, AS RECORDED UNDER RECORDING NUMBERS 8212060518 AND 8212060520, AND CORRECTED UNDER RECORDING NUMBERS 8307070635 AND 8307070636. EXCEPT THOSE PORTIONS CONVEYED TO THE CITY OF FEDERAL WAY BY INSTRUMENTS RECORDED UNDER RECORDING NUMBERS 201601080001121 20160108000113 AND 20160108000115. CUT = 5,050 C.Y. FILL = 1,450 C.Y. NET = 3,600 C.Y. (CUT) NOTE: QUANTITIES CALCULATED FROM EXISTING GRADE TO FINISH GRADE WITH ROAD SECTION TO SUBGRADE NOT REMOVED. STRIPPING OR SOIL SUITABILITY NOT INCLUDED. NOTE: THE ABOVE QUANTITIES ARE ESTIMATES ONLY, THEY ARE INTENDED FOR THE PERMITTING PROCESS. 00 NOT USE FOR BID PURPOSES. Know what's below. Call before you dig. NOTE: THIS APPROVAL. IS VOID I (ONE) YEAR AFTER APPROVAL DATE, THE CITY WILL. NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX—XXXXXX—XX APPROVED DATE -- z W 0 oll Q r- 0) (n4-t OD . ■,rr to C: Lo i) 0 04 C Cp < 0 �\ E '4t 0 U I 1 z ® 4 Nto 0 3 M U CO(04U9 Uj �0 ��` z v 0 u., -...� CL 49 W z J W J 0 DATE SEALED' -- �. JEL�� �11)�0F W A S,y�SO 40382 <v� s/ONAL���\ PROJECT MMAGIER COLLEEN HMM DESIIQV a) DRAVVN SA.J CHECKED GJ SEC T 2flo6 R 4E FILE NO DATE NAM= SCALE AS NOTED SHEET L ®E Lao 9LE NO 35072 0 APEX ENGINEERING LLC �2022 0 IRRIGATION CONTROL VALVE 0 UNKNOWN UTILITY MANHOLE FYI UNKNOWN UTILITY VAULT —:THE ----.'0HE— OVERHEAD POWER LINE --OHT-.----,.._ �..�,....._....._. OVERHEAD TELEPHONE LINE BURIED GAS LINE ASPHALT SURFACE CONCRETE SURFACE l... GRAVEL SURFACE U E 0 .. SOUTH .. TOWNSHIP FEDERALCITY OF O. OWNER 35000 PACIFIC HWY SOUTH, LLC P.O. BOX 94176 SEATTLE, WA 98124--6476 PHONE: (253) 826-5020 EINGINE'ER/SURVEYOR APEX ENGINEERING, LLC 2601 SOUTH 35TH, SUITE 200 TACOMA, WA 98409 PHONE': (253) 473-4494 1. COVER SHEET 2. GRADING AND TESC PLAN 3. TESC NOTES AND DETAILS 4. STORM PLAN 5. STORM PROFILES AND DETAILS 6. STORM PROFILES 7. STORM PROFILES 8. STORM NOTES AND DETAILS 9. 351ST STREET EAST PLAN AND PROFILE 10. 351ST STREET EAST GRADING DETAILS 11. PACIFIC HWY SOUTH IMPROVEMENTS 1'J Pnnn Akin CTnRI<I nI-TAII S 343RD ST PARK N RID£ S 344TH ST cc cc S 347TH ST S 348TH ST PARK N RIDE "' w Q S 35 ND ST SCALE: NTS P"N NOTES `EY 1. LOCATIONS OF OFFSITE BUILDINGS AND DRIVEWAYS FOR SURROUNDING AREA WERE OBTAINED FROM AERIAL MAPPING AND ARE APPROXIMATE ONLY. 6QVND.ARY/T' PHY SEE SHEET 14 OF 14 FOR BOUNDARY AND TOPOGRAPHIC INFORMATION 2. ADJACENT PROPERTY LINES WERE OBTAINED FROM PUBLIC SOURCES AND ARE APPROXIMATE ONLY. TAX PARCEL NUMBERS WERE OBTAINED FROM KING COUNTY WESSITE. 3. TO SCHEDULE A PRECONSTRUCTION MEETING OR INSPECTION CONTACT THE CITY'S PUBLIC WORKS DEPARTMENT PRECONSTRUCTION%INSPECTION NOTIFICATION PHONE NUMBER (253) 835-2700. 1 SITE AREA : 182,722 # SF. ( 4.2 ± ACRES ) PARCEL NUMBERS : 202104-9043, 202104-9155, 202104-9162, 202104-9163 ZONING : CE ( COMMERCIAL ENTERPRISE ) ON -SITE PAVING AND CURB : 163,025 f SF. RIGHT OF WAY DEDICATION : 0 SF. CRITICAL AREAS : 0 SF. TRACT AREAS : 0 SF. OWNER/DEVELOPER: 35000 PACIFIC HWY SOUTH, LLC SI M ADDRESS 35000 PACIFIC HWY S FEDERAL WAY, WA 98003 L.1Gl ''1L L�ilES�rR T ION LOTS 1, 2, 3 AND 4, KING COUNTY SHORT PLAT NUMBER 274023, RECORDED UNDER RECORDING NUMBER 8011050835, IN KING COUNTY, WASHINGTON; TOGETHER WITH THAT PORTION OF VACATED STATE HIGHWAY ADJOINING SAID LOTS 3 AND 4, AS RECORDED UNDER RECORDING NUMBERS 8212060518 AND 8212060520, AND CORRECTED UNDER RECORDING NUMBERS 8307070635 AND 8307070636. EXCEPT THOSE PORTIONS CONVEYED TO THE CITY OF FEDERAL WAY BY INSTRUMENTS RECORDED UNDER RECORDING NUMBERS 201601080001121 20160108000113 AND 20160108000115. CUT = 5,050 C.Y. FILL = 1,450 C.Y. NET = 3,600 C.Y. (CUT) NOTE: QUANTITIES CALCULATED FROM EXISTING GRADE TO FINISH GRADE WITH ROAD SECTION TO SUBGRADE NOT REMOVED. STRIPPING OR SOIL SUITABILITY NOT INCLUDED. NOTE: THE ABOVE QUANTITIES ARE ESTIMATES ONLY, THEY ARE INTENDED FOR THE PERMITTING PROCESS. 00 NOT USE FOR BID PURPOSES. Know what's below. Call before you dig. NOTE: THIS APPROVAL. IS VOID I (ONE) YEAR AFTER APPROVAL DATE, THE CITY WILL. NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX—XXXXXX—XX APPROVED DATE -- z W 0 oll Q r- 0) (n4-t OD . ■,rr to C: Lo i) 0 04 C Cp < 0 �\ E '4t 0 U I 1 z ® 4 Nto 0 3 M U CO(04U9 Uj �0 ��` z v 0 u., -...� CL 49 W z J W J 0 DATE SEALED' -- �. JEL�� �11)�0F W A S,y�SO 40382 <v� s/ONAL���\ PROJECT MMAGIER COLLEEN HMM DESIIQV a) DRAVVN SA.J CHECKED GJ SEC T 2flo6 R 4E FILE NO DATE NAM= SCALE AS NOTED SHEET L ®E Lao 9LE NO 35072 0 APEX ENGINEERING LLC �2022 BURIED GAS LINE ASPHALT SURFACE CONCRETE SURFACE l... GRAVEL SURFACE U E 0 .. SOUTH .. TOWNSHIP FEDERALCITY OF O. OWNER 35000 PACIFIC HWY SOUTH, LLC P.O. BOX 94176 SEATTLE, WA 98124--6476 PHONE: (253) 826-5020 EINGINE'ER/SURVEYOR APEX ENGINEERING, LLC 2601 SOUTH 35TH, SUITE 200 TACOMA, WA 98409 PHONE': (253) 473-4494 1. COVER SHEET 2. GRADING AND TESC PLAN 3. TESC NOTES AND DETAILS 4. STORM PLAN 5. STORM PROFILES AND DETAILS 6. STORM PROFILES 7. STORM PROFILES 8. STORM NOTES AND DETAILS 9. 351ST STREET EAST PLAN AND PROFILE 10. 351ST STREET EAST GRADING DETAILS 11. PACIFIC HWY SOUTH IMPROVEMENTS 1'J Pnnn Akin CTnRI<I nI-TAII S 343RD ST PARK N RID£ S 344TH ST cc cc S 347TH ST S 348TH ST PARK N RIDE "' w Q S 35 ND ST SCALE: NTS P"N NOTES `EY 1. LOCATIONS OF OFFSITE BUILDINGS AND DRIVEWAYS FOR SURROUNDING AREA WERE OBTAINED FROM AERIAL MAPPING AND ARE APPROXIMATE ONLY. 6QVND.ARY/T' PHY SEE SHEET 14 OF 14 FOR BOUNDARY AND TOPOGRAPHIC INFORMATION 2. ADJACENT PROPERTY LINES WERE OBTAINED FROM PUBLIC SOURCES AND ARE APPROXIMATE ONLY. TAX PARCEL NUMBERS WERE OBTAINED FROM KING COUNTY WESSITE. 3. TO SCHEDULE A PRECONSTRUCTION MEETING OR INSPECTION CONTACT THE CITY'S PUBLIC WORKS DEPARTMENT PRECONSTRUCTION%INSPECTION NOTIFICATION PHONE NUMBER (253) 835-2700. 1 SITE AREA : 182,722 # SF. ( 4.2 ± ACRES ) PARCEL NUMBERS : 202104-9043, 202104-9155, 202104-9162, 202104-9163 ZONING : CE ( COMMERCIAL ENTERPRISE ) ON -SITE PAVING AND CURB : 163,025 f SF. RIGHT OF WAY DEDICATION : 0 SF. CRITICAL AREAS : 0 SF. TRACT AREAS : 0 SF. OWNER/DEVELOPER: 35000 PACIFIC HWY SOUTH, LLC SI M ADDRESS 35000 PACIFIC HWY S FEDERAL WAY, WA 98003 L.1Gl ''1L L�ilES�rR T ION LOTS 1, 2, 3 AND 4, KING COUNTY SHORT PLAT NUMBER 274023, RECORDED UNDER RECORDING NUMBER 8011050835, IN KING COUNTY, WASHINGTON; TOGETHER WITH THAT PORTION OF VACATED STATE HIGHWAY ADJOINING SAID LOTS 3 AND 4, AS RECORDED UNDER RECORDING NUMBERS 8212060518 AND 8212060520, AND CORRECTED UNDER RECORDING NUMBERS 8307070635 AND 8307070636. EXCEPT THOSE PORTIONS CONVEYED TO THE CITY OF FEDERAL WAY BY INSTRUMENTS RECORDED UNDER RECORDING NUMBERS 201601080001121 20160108000113 AND 20160108000115. CUT = 5,050 C.Y. FILL = 1,450 C.Y. NET = 3,600 C.Y. (CUT) NOTE: QUANTITIES CALCULATED FROM EXISTING GRADE TO FINISH GRADE WITH ROAD SECTION TO SUBGRADE NOT REMOVED. STRIPPING OR SOIL SUITABILITY NOT INCLUDED. NOTE: THE ABOVE QUANTITIES ARE ESTIMATES ONLY, THEY ARE INTENDED FOR THE PERMITTING PROCESS. 00 NOT USE FOR BID PURPOSES. Know what's below. Call before you dig. NOTE: THIS APPROVAL. IS VOID I (ONE) YEAR AFTER APPROVAL DATE, THE CITY WILL. NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX—XXXXXX—XX APPROVED DATE -- z W 0 oll Q r- 0) (n4-t OD . ■,rr to C: Lo i) 0 04 C Cp < 0 �\ E '4t 0 U I 1 z ® 4 Nto 0 3 M U CO(04U9 Uj �0 ��` z v 0 u., -...� CL 49 W z J W J 0 DATE SEALED' -- �. JEL�� �11)�0F W A S,y�SO 40382 <v� s/ONAL���\ PROJECT MMAGIER COLLEEN HMM DESIIQV a) DRAVVN SA.J CHECKED GJ SEC T 2flo6 R 4E FILE NO DATE NAM= SCALE AS NOTED SHEET L ®E Lao 9LE NO 35072 0 APEX ENGINEERING LLC �2022 PROPOSED CONSTRUCT70N SEOLSYCE 1. CALL ONE -CALL LOCATE (811) FOR UTILITY LOCATES. 2. HOLD PRE -CONSTRUCTION CONFERENCE. 3. STAKE LIMITS OF CLEARING AND GRUBBING. 4. CLEAR AND GRUB AS NECESSARY TO INSTALL CONSTRUCTION ENTRANCE AND FILTER FABRIC FENCES. INSTALL THOSE FACILI TIES/BMP'S. 5. COMPLETE CLEARING AND GRUBBING OF PROJECT, INSTALLING EROSION CONTROL FACILITIES/BMP'S AS WORK PROGRESSES. 6. CONSTRUCT TEMPORARY SEDIMENT POND AND INTERCEPTOR SWALES. 7. INSTALL UTILITIES (SANITARY SEWER, STORM AND WATER), COMPLETE GRADING, COVER SYSTEM AS WORK PROGRESSES. PLANT 2 RELOCATION GRADING AND TESC PLAN 8. COMPLETE SITE GRADING. INSTALL EROSION CONTROL BMP S AS w Now WORK PROGRESSES. iE 9. INSTALL REMAINING UTILITIES, INSTALL CB INSERTS AS WORK ' { TN FEET) UN PROGRESSES. - 1 inch = 30 ft. cc10. MAINTAIN EROSION CONTROL FACILITIES/BMP'S. -- i VERTICAL DATUM: NGVD 29 Q 11. RELOCATE EROSION CONTROL FACILITIES/BMP'S OR INSTALL NEW/ADDITIONAL MEASURES AS WEATHER CONDITIONS REQUIRE TO PREVENT SEDIMENT LADEN RUNOFF FROM LEAVING THE SITE. 12. INSTALL REMAINING SITE IMPROVEMENTS, I.E. ROADWAYS, CURB, DRY UTILITIES SIDEWALK AND PAVEMENT. 13. HYDROSEED, FERTILIZE AND MULCH ALL DISTURBED AREAS. 14. COVER ALL DISTURBED AREAS PER SEASONAL REQUIREMENTS FOR SITE STABILIZATION. 15. CLEAN STORM DRAINAGE SYSTEM. , 16. AFTER SITE IS STABILIZED AND WITH CITY OF FEDERAL WAY / / APPROVAL, REMOVE ALL EROSION CONTROL FACILITIES/BMP'S. / / RIP RAP NOTES RIP RAP SHALL BE IN ACCORDANCE WITH SECTION 9-13.1 OF THE INSDOT/APWA STANDARD SPECIFICATIONS. RIP RAP TO BE REASONABLY 2 / 1 WELL GRADED WITH ROCK GRADATION AS FOLLOWS: 1. PASSING 8 INCH SQUARE SIEVE 100% OR MAXIMUM STONE SIZE 8" , PASSING 6 INCH SQUARE SIEVE 40-60% OR MEDIAN STONE SIZE 6" �f PASSING 2 INCH SQUARE SIEVE 0-10% OR MINIMUM STONE SIZE 2" C d / 8 / ro c a a u 13-4 a MI) ° d a 4 ° a ° d ° 'd C°d AB 255.0 I4 d a a a- a' 61 = a d d, a o a a .4 d d aA- a 4. 4 ° d- a ;-e a e ° a °. a a a- - 4 i d. n a a .7e e 4 ° a q a -V m e 1sj a •� tl 4 ° 4`� c a ll �1�.OP ° Y W1 a° - 1 a a° ?�1: n LY da .. d 4° 2 A ° n 4 a a `.: G a v aCd S.J� a tl e a- a s 4 4 V d e a u 4 a,d d a tl a d d d a 4 14 A a a 1.14 4 4 a da _ as 4a L d _ ° d°. I. � .�a0 ^ ?�� 4 - ° °� ° a 6 a 4` 'd •! 4 , 5p.� d 4 a 4 6 �� 10 0l� d e. �d ° '. a 4 'v ° a 'a��....-. d 4' - • a $ a 4 .. / a 3 4 ^ '- d v ° 4�. a IV d a a_. 1,4 a 4a 1IAl, 4 a v a .. 4 ° 4 •C e C}?'.. ° a a t1 a °. - i 4 e e a qa v- - a. 1 4 4+ e. e a a d ° 4. - 4a a I ° d a 4 a a e �! a �l 4 tl,° - m IS° •y�`n a . ° A `,� `t}yvo�.,_4,._° _ a d a4 e e < d a a 4 a V.tl a d a add °40 e- d'a4 4 / a a dV �`� 4 v MU e" a ; -a .a a . ' v 4 a a A d S�ddas d 4 7O J! . _ a 9 d - .d d C,,` 4 'A, ��' a - 4 v° .a - d. 9 a d a Ae i` LJ a °a as 4a° d. e,4 4 ° a._-e ° '. y °.\ FF=254.00 (� ' ° - d d •. d a 4 ®- 4 4 a / r J 4 d a a l< a 'a ° 4 d d 4. d 4 a e ° a a � d ��° da n CQ' � - 4 o' // yy� jI a d rye G 4 j # c -� 44 d p 1 1 a b 1 as �e C� qa d 4d W3.9./ d 4 d7I3Itl d a a d r `'° a ,mad a. SF d 2.94 y 4 a? 4'4 ' < a4 a 4�� 4 (n �? °°. 4 tl a 4 a II 4 1 e 4 g V�i d q sQ A �y�,. a 4 a a n ° a °10 - e a '4 a a '�, �,.. 5D ° a a .. a 'SD�_,_ d a a..-0 v a d e r_ �a - a A a -0.`� rI 4 A 4 I a ., a e V-..-m • . ,:9` d 'a, d 4 a 4- - .e AG, n{ d i q e a a s 4 d a 4 4 a a d . ° -'1° e. _sr e O A a e a }r.. ✓ 5��'� _ ...'I� 5y- / ' S Qj SD -SD -SD- D SD - SD - SD - Y1- SD �fl 4 0 f � r � r I / v 4 a� U ZG SID(--- 5va _ y Jv 11 LLL r $° ✓ so SID I TES-C LEGEND: .� .. � m . m m. Q CLEARING LIMITS INTERCEPTOR SWALE 0 0.5% MIN. SLOPE, PER DETAIL SHT 3. X X X S SILT FENCE, PER DETAILS SHT 3. IP CATCH BASIN INSERT, PER DETAILS SHT 3. IST SEDIMENT POND, PER DETAILS SHT 3. (MIN. SURFACE AREA AT RISER ELEV = 2,375 SF) © STABILIZED CONSTRUCTION ENTRANCE, PER DETAILS SHT 3. j ® RIP RAP, PER NOTES SHT 3. M { '� Q CHECK DAM, PER DETAILS SHT 3. wfU HYDROSEED, FERTILIZER AND MULCH, PER NOTE SHT 3. `w O APPROXIMATE SOIL STOCKPILE LOCATION. i "1 �] EXISTING UTILITY POLE TO REMAIN, PROTECT DURING CONSTRUCTION ® EXISTING CATCH BASIN TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST TO FINISH GRADE AS NECESSARY ) EXISTING SANITARY SEWER TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST TO FINISH GRADE AS NECESSARY. CONTRACTOR TO COORDINATE WITH LAKEHAVEN WATER AND SEWER DISTRICT AS NECESSARY. �I 9 I ® EXISTING WATER VALVE TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST TO FINISH GRADE AS NECESSARY. CONTRACTOR TO COORDINATE WITH LAKEHAVEN ■ IJ .■ WATER AND SEWER DISTRICT AS NECESSARY. EXISTING GAS VALVE TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST TO FINISH GRADE AS NECESSARY ® EXISTING TRANSFORMER TO REMAIN, PROTECT DURING CONSTRUCTION. CONTRACTOR TO COORDINATE WITH PUGET SOUND ENERGY AS NECESSARY. 70 EXISTING WATER METER TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST TO FINISH GRADE AS NECESSARY. CONTRACTOR TO COORDINATE WITH LAKEHAVEN j WATER AND SEWER DISTRICT AS NECESSARY. ® EXISTING LIGHT POLE TO BE RELOCATED, CONTRACTOR TO COORDINATE WITH PUGET SOUND ENERGY, WSDOT, AND CITY OF FEDERAL WAY AS NECESSARY �► ®€XIS77NG FENCE TO BE REMOVED QQ EXISTING LIGHT POLE TO BE REMOVED 1 EXISTING BLOCK WALL TO BE REMOVED EXISTING CATCH BASIN/PIPE TO BE REMOVED ! D EXISTING IRRIGATION CONTROL VALVE TO BE REMOVED/RELOCATED AS NECESSARY ® EXISTING UTILITY POLE TO BE RELOCATED, CONTRACTOR TO COORDINATE WITH ! PUGET SOUND ENERGY AS NECESSARY 15 EXISTING CULVERT TO BE REMOVED = ` s EXISTING FENCE TO REMAIN, PROTECT DURING CONSTRUCTION ' Q EXISTING FENCE TO BE RELOCATED, COORDINATE MTN ADJACENT PROPERTY OWNER AS NECESSARY 1® EXISTING UTILITY VAULT TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST I TO FINISH GRADE AS NECESSARY. CONTRACTOR TO COORDINATE WITH PUGET SOUND �ko ENERGY AS NECESSARY. 19 EXISTING BUILDING TO BE REMOVED - €XISTING CONCRETE TO BE REMOVED D i 3 - EXISTING ASPHALT TO BE REMOVED 1 GEOTECHNICAL NOTES 1. EARTHWORK AND MATERIALS SHALL CONFORM TO THE RECOMMENDATIONS PER THE GEOTECHNICAL ENGINEER. STRUCTURAL FILL AND FILL SOILS SHALL BE EVALUATED AND ACCEPTED BY THE GEOTECHNICAL ENGINEER PRIOR TO USE. 2. THE GEOTECHNICAL ENGINEER OR DESIGNATED REPRESENTATIVE SHALL BE ON SITE TO OBSERVE EARTHWORK AS NECESSARY. NOTE: THIS APPROVAL IS VOID 1 (ONE} YEAR AFTER APPROVAL DATE. THE CITY WILL NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. Know what's below. Call before you dig. PERMIT NO. XX-XXXXXX--XX APPROVED DATE a Oil O O) � N 't U) = 41 �1 Irj 0 LV tlJ W (1ELL 3 o � N E V 0 0 I F r- to N J 0ID o U co 0 V�:NC-4 Wo zXa q 0. vI O W Z J W I- J I- 10 DATE SEAL M 6'7-ZZ P4 WASh,�S0 � y 40382GIST <v� ONALR�-�G\� PROJECT MANAGER COLLEEN F•IAFFJS DEBK3N Grp DRAWN SAJ CHECKED GJ SEC 20 T 21iY R 4E 1E NO DATE 06/03/2022 SCALE T - W SHEET z OF 14 FLE NO =72 © APEX ENGINEERING �LLC20�22 w 0 U a N C] JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS OR EQUIVALENT TO ATTACH FABRIC TO POSTS. 2"X2" BY 14 Go. WIRE OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED f FILTER FABRIC ------------- z --- 6' MAX. --r- + POST SPACING MAY BE MINIMUM 4"x4" TRENCH u INCREASED TO 8' IF BACKFILL TRENCH WITH NATIVE SOIL WIRE BACKING IS USED OR 3/4" TO 1-1/2" WASHED GRAVEL NOTE: FILTER FABRIC FENCES SHALL BE INSTALLED ALONG 2"x4" WOOD POSTS, STEEL FENCE CONTOURS WHENEVER POSSIBLE POSTS, REBAR, OR EQUIVALENT MAINTENANCE STANDARDS 1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY. 2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3. IT 1S IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CANALIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT, 4. SEDIMENT MUST BE REMOVED WHEN THE SEDIMENT IS 6 INCHES HIGH, 5. 5. 1F THE FILTER FABRIC (GEOTEXPLE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE RFPLACFD. SILT FENCE (K.C. FIG. G3.6.A) N. T. S. 4li�T�.f1t.T1 �.1� -�I 2' MIN. I-�- SWALE SPACING DEPENDS ON SLOPE GRADIENT MAINTENANCE STANDARDS 1. DAMAGE RESULTING FROM RUNOFF OR CONSTRUCTION ACTIVITY SHALL BE REPAIRED IMMEDIATELY. 2. IF THE FACILITIES DO NOT REGULARLY RETAIN STORM RUNOFF, THE CAPACITY AND/OR FREQUENCY OF THE DIKES/SWALES SHALL BE INCREASED. INTERCEPTOR MALE (K.C. FIG. C.3.123) N. T. S. ROCK MUST COMPLETELY COVER THE BOTTOM AND SIDES OF THE DITCH 6" MIN. 24" MIN, 2H:1V SLOPES L=THE DISTANCE SUCH THAT POINTS A AND B ARE OF EQUAL ELEVATION 2"- 4" ROCK CHECK DAM SPACING CHECK DAMS (K.C. FIG. C.,313.A) N. T. S D A �=25' MIN. 4"- 8" QUARRY SPALLS IF A ROADSIDE DITCH IS PROVIDE FULL WIDTH OF PRESENT, INSTALL GEOTEXPLE DRIVEWAY CULVERT PER INGRESS/EGRESS AREA KCRDCS 12" MIN. NOTES: THICKNESS • PER KING COUNTY ROAD DESIGN AND CONSTRUCTION STANDARDS (KCRDCS), DRIVEWAYS SHALL BE PAVED TO EDGE OF R-O-W PRIOR TO INSTALLATION OF THE CONSTRUCTION ENTRANCE TO AVOID DAMAGING OF THE ROADWAY. • IT 1S RECOMMENDED THAT THE ENTRANCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD. MAINTENANCE STANDARDS 1. QUARRY SPALLS (OR HOG FUEL) SHALL BE ADDED IF THE PAD 1S NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. 2. IF THE ENTRANCE 1S NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF A WHEEL WASH, IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND. J. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC IF IT IS NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED. WASH WATER MUST BE PUMPED BACK ONTO THE SITE AND CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TO SURFACE WATERS. 4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 5. IF VEHICLES ARE ENTERING OR EXITING THE SITE AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING (SEE SECTION D.2.1.1) SHALL BE INSTALLED TO CONTROL TRAFFIC. STABILIZED CONSTRUCTION ENTRANCE (K.C. FIG. 0.2.1.4.A) N. T. S. PLANT 2 RELOCATION TESC NOTES AND DETAILS A PORTION OF THE SOUTH 1/2 OF THE S.E.1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON SOLID WALLS - FILTER MEDIA. FOR DEWATERING CATCH BASIN GRATE OVERFLOW \/\ POROUS BOTTOM NOTE: THIS DETAIL IS ONLY SCHEMATIC. ANY INSERT IS ALLOWED THAT HAS: • A MIN. 0.5 C.F. OF STORAGE, • THE MEANS TO DEWATER THE STORED SEDIMENT, • AN OVERFLOW, AND • CAN BE EASILY MAINTAINED. MAINTENANCE STANDARDS 1. ANY ACCUMULATED SEDIMENT ON OR AROUND INLET PROTECTION SHALL BE REMOVED IMMEDIATELY. SEDIMENT SHALL NOT BE REMOVED WITH WATER, AND ALL SEDIMENT MUST BE DISPOSED OF AS FILL ON SITE OR HAULED OFF SITE. 2. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY. 3. REGULAR MAINTENANCE IS CRITICAL FOR ALL FORMS OF CATCH BASIN/INLET PROTECTION. UNLIKE MANY FORMS OF PROTECTION THAT FAIL GRADUALLY, CATCH BASIN PROTECTION WILL FAIL SUDDENLY AND COMPLETELY IF NOT MAINTAINED PROPERLY. CATCH BASIN INSERT (K.C. FIG. C.3.9.8) N. TS KEY DIVIDER INTO SLOPE TO - PREVENT FLOW AROUND SIDES THE POND LENGTH SHALL BE 3 TO 6 TIMES THE MAXIMUM POND WIDTH PON r - r • +'r" " i RO�s�i'� EMERGENCY OVERFLOW SPILLWAY RISER DISCHARGE TO PIPE STABILIZED CONVEYANCE, SILT FENCE OR OUTLET OR LEVEL EQUIVALENT l SPREADER DIVIDER NOTE:__ - POND MAY BE FORMED BY BERM OR BY PARTIAL OR COMPLETE EXCAVATION SEDIMENT POND PLAN VIEW (K.C. FIG D.2.1.5.B) N. T. S RISER PIPE (PRINCIPAL CREST OF 6' MIN. BERM WIDTH SPILLWAY) OPEN AT TOP WITH EMERGENCY EMBANKMENT TRASH RACK PER FIG. 5A.I.0 SPILLWAY COMPACTEID 95% MODIFIED PROCTOR. DEWATERING SIN PERVIOUS MATERIALS --�---- SUCH AS GRAVEL OR DEVICE (SEE � w CLEAN SAND SHALL RISER DETAIL) --_-a�__��� _=-_-----_ 7�`5 NOT BE USED. WIRE -BACKED SILT DEWATERfNG FENCE, STAKED STRAIN BALES WRAPPED WITH ORIFICE DISCHARGE O STABILIZED FILTER FABRIC, OR CONCRETE BASE CONVEYANCE, OUTLET OR EQUIVALENT DIVIDER (SEE RISER DETAIL) LEVEL SPREADER SEDIMENT POND CROSS SECTION (K.C. FIG D.2.1.5. C) N. T. S POLYETHYLENE CAP PROVIDE ADEQUATE STRAPPING PERFORATED CORRUGATED (DEWATERING DEVICE, METAL RISER SEE NOTE 3.5' MIN. ATERTIGHT C UPLING TACK DEWATERING ORIFICE, WELD SCHEDULE 40 STEEL STUB MIN. DIAMETER AS PER CALCULATIONS NOTE. PERFORATED CORRUGATED 6" MIN. POLYETHYLENE (CPE)- DRAINAGE TUBING. DIAMETER 1$" IN_ MIN. 2" LARGER THAN DEWATERING ORIFICE., TUBING CONCRETE BASE `- ALTERNATIVELY, METAL SHALL COMPLY WITH ASTM STAKES AND WIRE MAY F667 AND AASHTO M294. BE USED TO PREVENT 7X RISER DIA, MIN, FLOTATION SEDIMENT POND RISER DETAIL (K.C. FIG. D.2.1.5.D) ATS. INFILTTRATION FACILITY NOTES: 1. DURING CONSTRUCTION AND UNTIL SITE 1S COMPLETELY STABILIZED, NO RUNOFF SHALL DISCHARGE DIRECTLY INTO THE INFILTRATION SYSTEM. 2. THE GEOTECHNICAL ENGINEER IS TO INSPECT THE FACILITY BEFORE, DURING, AND AFTER CONSTRUCTION TO ENSURE THE FACILITY IS CONSTRUCTED CORRECTLY, THAT THE INFILTRATION SURFACE IS NOT COMPACTED AND THE SYSTEM IS PROTECTED FROM SEDIMENTATION. CONTRACTOR SHALL COORDINATE. 3. IMMEDIATELY AFTER FACILITY EXCAVATION/CONSTRUCTION, THE GEOTECHNICAL ENGINEER IS TO PERFORM A SUFFICIENT NUMBER OF INFILTRACTION TESTS (2 MINIMUM) TO VERIFY IF THE INFILTRATION RATES AND DEPTHS TO GROUND WATER AND/OR IMPERVIOUS SOIL LAYER USED FOR DESIGN ARE STILL ACCEPTABLE. IF TESTS INDICATE THAT THE FACILITY WILL NOT FUNCTION AS DESIGNED, THIS INFORMATION SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CITY OF LACEY AND APEX ENGINEERING PLLC. CONTRACTOR SHALL COORDINATE. 4. BOTTOMS OF INFILTRATION SYSTEMS SHALL NOT BECOME COMPACTED. LIMIT CONSTRUCTION VEHICLE ACCESS AT ALL TIMES. 5. AFTER INSTALLATION, DELINEATE THE IMMEDIATE AREA WITH PROTECTION FENCING TO PREVENT VEHICLES/TRAFFIC TRAVERSING THE INFILTRATION SYSTEM AREA. PROTECT AREA AT ALL TIMES. 6, CONFORM TO THE RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER. KING COUNTY MULCHING NOTES AS A TEMPORARY COVER MEASURE, MULCH SHOULD BE USED., 1. ON DISTURBED AREAS THAT REQUIRE COVER MEASURES FOR LESS THAN 30 DAYS. 2. AS A COVER FOR SEED DURING THE WET SEASON AND DURING THE HOT SUMMER MONTHS. 3. DURING THE WET SEASON ON SLOPES STEEPER THAN 3HA V WITH MORE THAN 10 FEET OF VERTICAL RELIEF. MAINTENANCE STANDARDS: 1. THE THICKNESS OF THE MULCH COVER MUST BE MAINTAINED. 2. ANY AREAS THAT EXPERIENCE EROSION SHALL BE RE -MULCHED AND/OR PROTECTED WITH A NET OR BLANKET. IF THE EROSION PROBLEM IS DRAINAGE RELATED, THEN THE DRAINAGE PROBLEM SHALL BE ASSESSED AND ALTERNATE DRAINAGE SUCH AS INTERCEPTOR SWALES MAY BE NEEDED TO FIX THE PROBLEM AND THE ERODED AREA RE -MULCHED. MULCH STANDARDS AND GUIDELINES: • STRAW: 2" TO 3" THICK, 2-3 BALES PER 1,000 SF OR 2-3 TONS PER ACRE • WOOD FIBER CELLULOSE: APPROXIMATELY 25-30 LBS PER 1,000 SF OR 1,000 TO 1,500 LBS PER ACRE • COMPOST: 2" THICK MIN., APPROXIMATELY 100 TONS PER ACRE (APPROXIMATELY 800 LBS PER CUBIC YARD) • HYDRAULIC MATRICES (BONDED FIBER MATRIX): APPLY AT RATES FROM 3,000 LBS PER ACRE TO 4,000 LBS PER ACRE AND BASED ON MANUFACTURERS'RECOMMENDAiIONS. • CHIPPED SITE VEGETATION: 2'THICK MIN. EROSION/8801 AENT CONTROL. NOTES: 1. APPROVAL OF THIS EROSION/SEDIMENTATION CONTROL (ESC) PLAN DOES NOT CONSTITUTE AN APPROVAL OF PERMANENT ROAD OR DRAINAGE DESIGN (I.E. SIZE AND LOCATION OF ROADS, PIPES, RESTRICTORS, CHANNELS, RETENTION FACILITIES, UTILITIES, ETC.). 2. THE IMPLEMENTATION OF THESE ESC PLANS AND THE CONSTRUCTION, MAINTENANCE REPLACEMENT, AND UPGRADING OF THESE ESC FACILITIES IS THE RESPONSIBILITY OF TIME APPLICANT/CONTRACTOR UNTIL ALL CONSTRUCTION IS APPROVED. 3. THE BOUNDARIES OF THE CLEARING LIMITS SHOWN ON THIS PLAN SHALL BE CLEARLY FLAGGED IN THE FIELD PRIOR TO CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE FLAGGED CLEARING LIMITS SHALL BE PERMITTED. THE FLAGGING SHALL BE MAINTAINED BY THE APPLICANT/CONTRACTOR FOR THE DURATION OF CONSTRUCTION. 4. THE ESC FACILITIES SHOWN ON THIS PLAN MUST BE CONSTRUCTED IN CONJUNCTION WITH ALL CLEARING AND GRADING ACTIVITIES, AND IN SUCH A MANNER AS TO INSURE THAT SEDIMENT LADEN WATER DOES NOT ENTER THE DRAINAGE SYSTEM OR VIOLATE APPLICABLE WATER STANDARDS. 5. THE ESC FACILITIES SHOWN ON THIS PLAN ARE THE MINIMUM REQUIREMENTS FOR ANTICIPATED SITE CONDITIONS. DURING THE CONSTRUCTION PERIOD, THESE ESC FACILITIES SHALL BE UPGRADED (I.E. ADDITIONAL SUMPS, RELOCATION OF DITCHES AND SILT FENCES, ETC.) AS NEEDED FOR UNEXPECTED STORM EVENTS. 6. THE ESC FACILITIES SHALL BE INSPECTED DAILY BY THE APPLICANT/CONTRACTOR AND MAINTAINED AS NECESSARY TO ENSURE THEIR CONTINUED FUNCTIONING. 7. ANY AREA STRIPPED OF VEGETATION, INCLUDING ROADWAY EMBANKMENTS, WHERE NO FURTHER WORK IS ANTICIPATED OR A PERIOD OF 2 DAYS (WET SEASON) OR 7 DAYS (DRY SEASON), SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC METHODS (I.E. SEEDING, MULCHING, NETTING, EROSION BLANKETS, ETC.) 8. ANY AREA NEEDING ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN 15 DAYS. 9. THE ESC FACILITIES ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED A MINIMUM OF ONCE A MONTH OR WITHIN THE 24 HOURS FOLLOWING A STORM EVENT. 10. AT NO TIME SHALL MORE THAN ONE FOOT OF SEDIMENT BE ALLOWED TO ACCUMULATE WITHIN A CATCH BASIN, ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM. 11. STABILIZED CONSTRUCTION ENTRANCES AND WASH PADS SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES MAY BE REQUIRED TO INSURE THAT ALL PAVED AREAS ARE KEPT CLEAN FOR THE DURATION OF THE PROJECT. 12, WET SEASON REQUIREMENTS AS DESCRIBED IN APPENDIX D, SECTION 0.2.4.2 OF THE KCSWDM ARE IN EFFECT BEGINNING OCTOBER 1 THROUGH APRIL 30. 13. ANY PERMANENT RETENTION/DETENTION FACILITY USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY EROSION CONTROL MEASURES AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE PERMANENT FACILITY IS TO FUNCTION ULTIMATELY AS AN INFILTRATION OR DISPERSION SYSTEM, THE FACILITY SHALL NOT BE USED AS A TEMPORARY SETTLING BASIN. NO UNDERGROUND DETENTION TANKS OR VAULTS SHALL BE USED AS A TEMPORARY SETTLING BASIN. 14, WHERE SEEDING FOR TEMPORARY EROSION CONTROL IS REQUIRED, FAST GERMINATING GRASSES SHALL BE APPLIED AT AN APPROPRIATE RATE (I.E. ANNUAL OR PERENNIAL RYE APPLIED AT APPROXIMATELY 80 POUNDS PER ACRE), 15. WHERE STRAW MULCH FOR TEMPORARY EROSION CONTROL IS REQUIRED, IT SHALL BE APPLIED AT A MINIMUM THICKNESS OF TWO INCHES. 16. MANAGEMENT PRACTICES PROVIDING SIGNIFICANT TREE PROTECTION SHALL BE PROVIDED PER SECTION 19.120 OF FWRC. IA - SEEDING NOTES 1. THE BEST TIME TO SEED IS APRIL i THROUGH JUNE 30, AND SEPTEMBER 1 THROUGH OCTOBER 15. AREAS MAY BE SEEDED BETWEEN JULY 1 AND AUGUST 31, BUT IRRIGATION MAY BE REQUIRED IN ORDER TO GROW ADEQUATE COVER. AREAS MAY ALSO BE SEEDED DURING THE WINTER MONTHS, BUT IT MAY TAKE SEVERAL MONTHS TO DEVELOP A DENSE GROUNDCOVER DUE TO COLD TEMPERATURES. THE APPLICATION AND MAINTENANCE OF MULCH IS CRITICAL FOR WINTER SEEDING. 2. TO PREVENT SEED FROM BEING WASHED AWAY, CONFIRM THAT ALL REQUIRED SURFACE WATER CONTROL MEASURES HAVE BEEN INSTALLED. 3. THE SEEDBED SHOULD BE FIRM BUT NOT COMPACTED BECAUSE SOILS THAT ARE WELL COMPACTED WILL NOT VEGETATE AS QUICKLY OR THOROUGHLY. 4. IN GENERAL, 10-20-20 N-P-K (NITROGEN -PHOSPHORUS -POTASSIUM) FERTILIZER MAY BE USED AT A RATE OF 90 POUNDS PER ACRE. SLOW -RELEASE FERTILIZERS ARE PREFERRED BECAUSE THEY ARE MORE EFFICIENT AND HAVE FEWER ENVIRONMENTAL IMPACTS. IT IS RECOMMENDED THAT AREAS BEING SEEDED FOR FINAL LANDSCAPING CONDUCT SOIL TESTS TO DETERMINE THE EXACT TYPE AND QUANTITY OF FERTILIZER NEEDED. THIS WILL PREVENT THE OVERAPPLICATION OF FERTILIZER. DISTURBED AREAS WITHIN 200 FEET OF WATER BODIES AND WETLANDS MUST USE SLOWRELEASE LOW -PHOSPHORUS FERTILIZER (TYPICAL PROPORTIONS 3-1-2 N-P-K). 5. THE FOLLOWING REQUIREMENTS APPLY TO MULCHING: a. MULCH IS ALWAYS REQUIRED FOR SEEDING SLOPES GREATER THAN 3H:1V (SEE SECTION D.4.2.1 OF THE 2016 KING COUNTY SURFACE WATER DESIGN MANUAL). b. IF SEEDING DURING THE WET SEASON, MULCH IS REQUIRED. c. THE USE OF MULCH MAY BE REQUIRED DURING THE DRY SEASON AT THE COUNTY'S DISCRETION IF GRASS GROWTH IS EXPECTED TO BE SLOW, THE SOILS ARE HIGHLY ERODIBLE DUE TO SOIL TYPE OR GRADIENT, THERE IS A WATER BODY CLOSE TO THE DISTURBED AREA, OR SIGNIFICANT PRECIPITATION IS ANTICIPATED BEFORE THE GRASS WILL PROVIDE EFFECTIVE COVER. d. MULCH MAY BE APPLIED ON TOP OF THE SEED OR SIMULTANEOUSLY BY HYDROSEEDING. 6. HYDROSEEDING IS ALLOWED AS LONG AS TACKIFIER IS INCLUDED. HYDROSEEDING WITH WOOD FIBER MULCH IS ADEQUATE DURING THE DRY SEASON. DURING THE WET SEASON, THE APPLICATION RATE SHALL BE DOUBLED BECAUSE THE MULCH AND TACKIFIER USED IN HYDROSEEDING BREAK DOWN FAIRLY RAPIDLY IT MAY BE NECESSARY IN SOME APPLICATIONS TO INCLUDE STRAW WITH THE WOOD FIBER, BUT THIS CAN BE DETRIMENTAL TO GERMINATION. 7. AREAS TO BE PERMANENTLY LANDSCAPED SHALL USE SOIL AMENDMENTS. GOOD QUALITY TOPSOIL SHALL BE TILLED INTO THE TOP SIX INCHES TO REDUCE THE NEED FOR FERTILIZER AND IMPROVE THE OVERALL SOIL QUALITY. MOST NATIVE SOILS WILL REQUIRE THE ADDITION OF FOUR INCHES OF WELL -ROTTED COMPOST TO BE TILLED INTO THE SOIL TO PROVIDE A GOOD QUALITY TOPSOIL. COMPOST USED SHOULD MEET SPECIFICATIONS IN REFERENCE 11-C OF THE 2016 KING COUNTY SURFACE WATER DESIGN MANUAL. 8. THE SEED MIXES LISTED BELOW INCLUDE RECOMMENDED MIXES FOR BOTH TEMPORARY AND PERMANENT SEEDING. THESE MIXES, WITH THE EXCEPTION OF THE WETLAND MIX, SHALL BE APPLIED AT A RATE OF 120 POUNDS PER ACRE. THIS RATE MAY BE REDUCED IF SOIL AMENDMENTS OR SLOW -RELEASE FERTILIZERS ARE USED. LOCAL SUPPLIERS SHOULD BE CONSULTED FOR THEIR RECOMMENDATIONS BECAUSE THE APPROPRIATE MIX DEPENDS ON A VARIETY OF FACTORS, INCLUDING EXPOSURE, SOIL TYPE, SLOPE, AND EXPECTED FOOT TRAFFIC. ALTERNATIVE SEED MIXES APPROVED BY THE COUNTY MAY BE USED. % WEIGHT % PURITY % GERMINATION CHEWINGS OR RED FESCUE (FESTUCA RUBRA 40 98 90 VAR. COMMUTATA OR FESTUCA RUBRA) ANNUAL OR PERENNIAL RYE 40 98 90 (LOLIUM MULTIFLORUM OR LOLIUM PERENNE) REDTOP OR COLONIAL BENTGRASS 10 92 85 (AGROSTIS ALBA OR AGROSTIS TENUIS) WHITE DUTCH CLOVER (TRIFOLIUM REPENS) 10 98 90 MAINTENANCE STANDARDS FOR SEEDING: 1. ANY SEEDED AREAS THAT FAIL TO ESTABLISH AT LEAST 80 PERCENT COVER WITHIN ONE MONTH SHALL BE RESEEDED. IF RESEEDING IS INEFFECTIVE, AN ALTERNATE METHOD, SUCH AS SODDING OR NETS/BLANKETS, SHALL BE USED. IF WINTER WEATHER PREVENTS ADEQUATE GRASS GROWTH, THIS TIME LIMIT MAY BE RELAXED AT THE DISCRETION OF THE COUNTY WHEN CRITICAL AREAS WOULD OTHERWISE BE PROTECTED. 2. AFTER ADEQUATE COVER IS ACHIEVED, ANY AREAS THAT EXPERIENCE EROSION SHALL BE RE -SEEDED AND PROTECTED BY MULCH. IF THE EROSION PROBLEM IS DRAINAGE RELATED, THE PROBLEM SHALL BE FIXED AND THE ERODED AREA RE -SEEDED AND PROTECTED BY MULCH. 3. SEEDED AREAS SHALL BE SUPPLIED WITH ADEQUATE MOISTURE, BUT NOT WATERED TO THE EXTENT THAT IT CAUSES RUNOFF Know what's below. Call before you dig. NOTE: THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER APPROVAL DATE. THE CITY WILL NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX-XXXXXX-XX APPROVED DATE Q z i✓<J r0 Z 0nrn p7 `~IttO _ ID I I d W'f4 d °D ` n to Cp N +• 01 �°0 v o N E a� U I to 0 N �.s 0 co N Q (o Ocm 00 cri .jz wQ =x_<6 rr" U �v c\l z (, o CC cl)OL o ® Q l� W Z J W J 0 DATE SEALED PIR) WASSC) 40382 ONAL PROJECT MMAGiER DEBK)N G J DRAWN SAJ CHECKED QJ SEC 20 T 21N R 'E FLE NO DATE 106/0312 22 SCALE AS NOT® SHEET !-OF 9 FLE NO 35072 <APEX ENGINEERING LLC 2022 11 PLANT 2 RELOCATION GRAPHIC SCALE STORM PLAN ft." Wms Q COALESCING PLATE OIL/WATER SEPARATOR 30 ° 15 30 60 A PORTION OF THE SOUTH 112 OF THE S.E.114 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M., QLDCASTLE PRECAST MODEL 816-2-CPS W/ HEAVY TRAFFIC LID/TOP CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON PER DETAIL ON SHEET 8 ( IN FEET) _ _ RIM = 252.26 (CENTER OF LID) 1 inch = 30 ft. / µ-- 257 " I.E. 8" IN (E) = 244.72 VERTICAL DATUM: NGVD 29 I.E. 8" OUT (W) = 244.47 rw PRESETTLING VAULT SEE DETAIL ON SHEET 7 �. I.E. 18" (S) = 242.520 / I.E. 8" (E) = 242,50 256 _ ! :. , a I.E. 18" (N) = 243.50 ` ° � 610POD BIOFILTER d MODEL BPU--8161B A ^ .d � d d v SEE DETAIL ON SHEET 8 RIM = 252.28 (CENTER OF VAULT) d d I.E. IN 18" (S) = 243.46 I.E. OUT 18" N = 242.96 253 255�� G C a c a d e'a. n ° `.'1 ( / gSTC 4. T_YPE1 = a ° d ® INFILTRATION VAULT ° STA: +54.52 344 48' L 4 ° ° d SEE DETAIL ON SHEET 7 / d A d 4 STCB#15, TYP s 4 ° G q ° \ a'� S ° ;ar I.E. 18" {E) = 242.85 / 91 1 "ADS N-12 ®1a45% STA: 14+95i5 , 311,99 L ° d d d ,,` d . a a r. 252 ;5g 86 LF 12 A --12 ®gp.50 q d - ° d d d CB#i3, TYPE 1 ® a G :, ` ° <, ,; ��, . g O FORTRANS 50006 dj pH CONTROL SYSTEM STA 12 16.14 ?a.r,A 2' L c / / 4 1 d ° N�- d d . ' n to �� d d OR APPROVED EQUAL STCB#16,' TYPE 1° d ., -J\ d n I / a ^ ,�ti /♦ ° d a A ° ° e e STA: 1.5+72.88 274.55' L.° d d 4 d° A d 41' 1 4 d � d d 1 a _ d d d a d. r {/ ,'/� ] I d 4 -✓ � �� Pee � ✓ ' !_, a ^- .i u ° ® e ' a � ° a a � �AI . a .. d a ., �, � 4 a j a. ° v15 ,a°p r.} s ° 4e- ,,d, d.. ° ` i °E. I a°- A CB 11, TYPE i �°J ° ° B#10, TYPE 48"0 ° 'a d 'a d a ° ° ST 11 �86.82, 238.11 L q d°' �® A. 12+59:83, 265 2 a ° a d . 4 . J W ° �f'r� 1 " -1- -,�,- __ 4_ � a e v 0' j q '9' 12 G . d ' �!T �� . �. _- __ -- _--� / q , G Ll a ° ASS �N_. 12 2 0 d q 4 ° a a ° d � °'� � e "'sue, ° ., �° � STC9#12,°dTYPF"1L STA: 15+41:$, 174.5$' L ° 4 d a <f - \ 4 a d a CI d a ° d 4 - 4 G ql a v) p d tl 4. VAULT E 4. ' d . 1 1 e 1[.�E _ 242.8 r - - a a ba 4 12+29.6T t q l ° 9 T8 ADS N= 2 0 0.56% ° A A DRAIN #1, - g ° T)PE 2 48" y A: 14+57.76, k70.40 - ° • d e ^° S A:' 12+36.05,'� 1 8.91' L a °n {° ' �41 °tF 1$"a ADS N 2 1.00� S rr d � aCn tld % a a. a . a 41 168 LF I2" A S N-12 00.78% ° n d a d qa A 4 i I . d / A d °q n• 7 LF 1&" ADS --12 0 0.57% d ° a d -♦n c ° c r1 I ° e d c ° d a a ;1 ° d° n a �� n `Y a d a - A _ u, r �) 4- aST'CB#7,' T i E 1 t. _ °° STA:' 15+33,74,1 48.0 I �` N % r 35 LF Il °ADS- ---12- 9� 24 LF a ° �° 7 8 -ADS iN-12 0 28.14% a� d eSTC6#6, f 2a- 8'0 1 q 18° ADS N�12 " 4 A d d 8 LF 8 ADS N-12 0 1.0p% d e ''STA: 14+ 8.51, 48. {7 L � � 10.04% y d a d ° d p v PE " a G �'�' ° 4 FLOB#S iYiER2 60"o a a 3, T°, da d `, tls --� 7q o TC XPE' 2, � 46� r �� d 4 d SFF E L ON SHEET 5.° a STA: +18.29, 85.23 L 1 a STA: 12+4 0, 9759L 215r LF 12 ADDS N-12 O 0.40% � �° , � �-k 2q g _ a �k 4 / 4 a ° ad35 L 12" tl,D.l. 0 .51% r - ` d 33 LF 18" AbS N-12 °1.00% a a'' d "u ` L'' '� �� _�-SD STCB#5, TYPE' 1 4 ., d d ° ° a ^ + _ d a q ST�1 11+09.25, 51., L low 6 ° d Q d� d �• r / _.._ n d {%M O � 26 LF. 12 AD d 12 2 �'i7 ,_ V c " 0.50%9 '� ° d �a C.° e 141 LF 1.2 D� 4 d a d STC13#4, ` E°-°°48"0 S#8, TYPE 1 ST' :j 14+77.88, 19.16' L 38 LF 12" D.I. 00.57 Y� 246" Jrpp, /� .•, °,�' �. 3TCB#9, TYPE 1 STA. 14+77.88, 19.16' R I 104100 - EE PLAN D PROFILE ON11+00 EFT 9 • s� 7� G D�� �� » -G s - o sD -- Sri- - sD -- 1SD , su A, -if3 7 sib- a. ° 54. I i, O ..� \fib` l sb 4 0 .- j 244... NOTES 1. STATION AND OFFSET INFORMATION BASED ON CENTERLINE OF 351ST. 2. SEE STORM PROFILES ON SHEETS 5, 6, AND 7. Know what's below. Call before you dig. Structure Table Structure Name Structure Details AREA DRAIN 11 I.E. RIM = 253.93 6" (NE) = 250.92 RIM = 252.05 STCB#1 I.E. 18" (SW) = 242.90 I.E. 18" (NW) = 242.90 RIM = 252.39 I.E. 12" (E) = 244.80 STCB#2 I.E. 12" (S) = 244.80 I.E. 12 (N) = 244.80 I.E. 18" (W) = 245.24 I.E. 8" (NW) = 244.80 RIM = 251.89 STCB#3 I.E. 18" (E) = 244.91 I.E. 18" (N) = 244.91 RIM = 252.23 STCB#4 I.E. 12" (W) = 245.99 I.E. 12" (N) = 245.99 STCB#5 RIM = 249.90 I.E. 12" (E) = 246.70 RIM = 250.04 STCB#6 I.E. 12" (S) = 245.66 I.E. 12" (NE) = 245.66 I.E. 12" (W) = 245.66 STCB#7 RIM = 249.40 I.E. 12" (SW) = 246.00 RIM = 248.21 STC13#8 I.E. 12" (SE) = 245.84 I.E. 12" (N) = 245.84 STCB#9 RIM = 248.21 I.E. 12" (NW) = 246.03 RIM = 252.00 I.E. 12" (NW) = 246.11 STC8#10 I.E. 12" (E) = 246.11 I.E. 12" (W) = 246.11 I.E. 12" (S) = 246.11 STCB#11 RIM = 249.76 I.E. 12" (E) = 246.50 RIM = 253.21 STCB#12 I.E. 6" (SW) = 250.50 I.E. 12" (W) = 250,00 RIM = 251.14 STCB#13 I.E. 12" (NE) = 247.50 I.E. 12" (SE) = 247.50 RIM = 252.96 STCB#14 I.E. 12" (E) = 249.50 I.E. 12" (SW) = 249.50 RIM = 254.47 STCB#15 I.E. 12" (E) = 250.82 I.E. 12" (W) = 250.82 STCB#16 RIM = 254.47 I.E. 12" (W) = 251.25 NOTE: THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER APPROVAL DATE. THE CITY WILL NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX--XXXXXX-XX APPROVED DATE a 0Cnrn Q� N1*O 044 I1 LO oN C 4-1 Cif 0 N 3 am o� U P'7 FU- It N O Q ^ N U O w� zxa cc o v 2 N U.0 � a � Q C) CL O Q Cf) W z J W _J I..., U DATE SEALED Z -7- ZZ WASy�y0 PROJECT MANAQER COLLEEN HARFI S DESM Gj DRAWN SAJ CHECKED QJ SEC R T 21N R 4E F LE NO DATE 06/0812022 SCALE 'r - 20, SHEET 4 OF i4 FILE NO 3W72 9 APEX ENGINEERING LLC 2022 PLANT 2 RELOCATION STORM PROFILES AND DETAILS A PORTION OF THE SOUTH I/2 OF THE S.E. 1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M., CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON 2581 1 ---T--- I I I - . - - -T- - ....... 258 258 I EXISTING GROUND EXISTING GROUND} PROPOSED GRADE PROPOSED GRADE - I 252 252` 252 -_ 7 LF! 8" ADS N-12 0 28.14%' PRESETTLING VAULT SEE DETAIL ON SHEET 7 I I.E. 18" (S) = 242.50 I.E. 8" (E) = 242.50 I.E. 18" (N) = 243.501 240 234 228 C00 " I cV N Clj N N 1,0 N 1 4_ 8 LF 8" ADS N-12 0 1,00% \ � I 246 246 35 LF 38 LF INFILTRATION VAULT 215 LF 12 ADS N-12 0 9.40% 12" D.I. 12 D.I.''' SEE DETAIL ON SHEET 7 0 0.51% @ 0.50% I.E. 18" E = 24 .85 ST 8#2, TYPE-2 - 60"0 FL W SPUTTER PE. DETAIL ON SHEET 5 STA: 12+48.70 97;59' L RI = 252.39 _ - 1.E,. 12"_ (E) = 24480. I.E.! 12" (S) = 244F80 I.E.; 12" (N) = 244780 I.E. 18" (W) = 245.24 I.E. 8" (NW) = 244.80 COALESCING' PLATE OILMTER SEPARATOR - OLDCASTLEi PRECAST MODEL 816-2-CPS W/ HEAVY; TRAFFIC LID/TOP PER DETAIk ON SHEET 8 I RIM = 252�26 (CENTER OF LID) I.E. 8" IN (E) = 244.72 q l.E. 8" OUF (W) = 244.47 0 --- w I N o w a a to cn '^ N CV N CV rn N CV 3TCB#6,--TYPE 2._= 48"0 STA: 14+98.51 48,00' L RIM = 250.04 I.E. 12" ($) = 245.66 I.E. 12" (NE) = 245.66 " - - - -- - I.E; 12 (W)--= 245,66 :.STCB#8, TYPE STA: 14+77.88 19.16' Lj RIM = 248.21! I.E. 12". (SE) = 245.84! I.E. 1 �," (N) - 245.84 STORM I PIPE CENTERLINE SCALE' 1" = 30' H 3'V c� CL7 CD 'd- h N N r.j prj ti "I- N CV N N N N N Ln N N N N cq - - 240 STCB#O, TYPE 1 STA: 1 4+ 77.88 19.16' R RIM =; 248.21 -- - I.E. 12P (NW) = 246.03 N CN col r< C}- N 234 228 LF j 18" ADS N-12J 0 0.66% 240 --_ - - - STCB#1, TYPE 2 _ 48"0 STA: 12+38.05 188.91' L RIM = ! 252.05 I.E. 18" (SW) = 242.90 I.E. 18" (NW) = 242.90 6 LF 18" SIDS N-12 ® 1.00% 234 L 228 EL n N Un N ___1258 F_�W�m - - 246 i 33 LIF 8" ADS N- Z 0 1.00% LJ - - - 240 S�0#2, TYPE 2 - 60"0 FLOW SPUTTER PER DETAIL ON SHEET 5 STA: 12+48.70 97.59' L RIM = 252.39 ---I.E. 12" (E) = 244.80 BIOPOD 00FILTER ! I.E. 12" (S) = 244.80 MODEL BPU 8161E I.E. 12" (N) = 244.80 SEE DETAIL ION SHEET 8 11. 18" (W) = 245.24 RIM = 252.28 (CENTER OF1 VAULT) I.E. 8" (NW) = 244.80 I.E:..18" {S) !.=..-243..46 .... _ . _ - -- .. -� 234 I.E. 18" (N) � = 242.96 STCB#3, TYKE 2 -, 48"0 STA: 12+18;29 85.23' L ©, j RIM = 251.89 STORM 2 I.E. 18" (E) '= 244J91 I.E-TS"--(N).: =..2441 91 PIPE CENTERLINE SCALE 1" = 30' H 1" = 3' V 7 LF 18" SIDS N-12 0 0.877. 24 LF 18" ADS N-12 OE 10.047. E I � � I PRESEITLING VAULT SEE DETAIL ON SHEET 7 I.E. 18' (S) = 242.50 I.E. 8" ; (E) = 242.50 - LE-1 8"- (N) = 24150 - - I ��O �t L N L h co O N Lc) CV N N N N N N N N N N N 228 N N 1( TO OIL � � + CB, TYPE 2-60"0 WA TER SEPARATOR -- STEPSAADDER C4 REMOVABLE i DOWNTURNED ELBOW ti 12" 24" SOLID TO BYPASS LOCKING LID CONVEYANCE `FROM pH +ti CONTROL I _ SYSTEM PLr4N VFW 252 250 -- 248 - 246 - 244 -- 1, E. 8" (NW) DIAA M - ')F) ZO (E)- _-244:80 = 245,24 = 244.80 PRORLE VIEW STCB#2 OIL CONTROL BYPASS FLOW SPUTTER DETAIL SCALE 1" = 1' Know what's below. Call before you dig. NOTE: THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER APPROVAL DATE. THE CITY WILL NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX-XXXXXX-XX APPROVED DATE 0 2 a» 0rrnrn p7 N � u7 cn ro an C F) p N C41 1� [n < 0 04 E U to LO z 0 P rD QW oD � J co CID Oat � Wm: Xa� Cho U�3 04 °� z ti 0 z� Q a a W z J W F-- J �- U DATE SEALED 13� WAS z 40382 SSAGIST ON A L�E���? PROJECT MANAGER COLLEEN HAFM DERV 2J DRAWN SAJ 0 ECG GJ SSE2TnlC 20 T R 4E F LE NO DATE 08/03/2022 SCALE r - 30' SHEET 5 OF i4 RX NO =72 0 APEX ENGINEERING LLC 2022 PLANT 2 RELOCATION 7 258 Wf 246 240 234 C� CN STORM PROFILES A PORTION OF THE SOUTH 112 OF THE S.E.1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, Vl/ K CITY OF FEDERAL WAY, KING COUNTY, 'WASHINGTON - - 258 258 r - -i . . .. - - FASTIK, GROUND 1 PROPOSED GRAD N-12 .01% 188 L� S2p ADS STCB#12, TYPE 1L ADS N-12 ® 78� 168 LF 12 STA:. 15+41.08 174.58' L RIM = 253.21 I.E. 6" (SW) = 250.50 STC13#10, TYRE 2 - 48'0 I.E. 12" W) =250.00 STA: 12+59.83 265,27' L RIM = 252.06 STCB# , TYPE 2 - 60 0 I.E. 12p (NW) = 246.11 -FLOW LITTER I.E. 12 fE) 246.11 - TAIL ON SHEET 5 PER D IS. 12" (W) = 246.11 STA: 1 +48.70 97.59' L I.E. 12" (S) _ 246.11 RIM = 252.39 I. E. 12 (E) = 244.80 I.E. 12 {S) = 244.80 ! a w +� STORM ORM 3 . 1= _.___. N) _ 244.80,, __._ o � PIPE CENrERLrNE I.E. 18 (W) = 245.24 ; I.E. 8" (NW) = 244.80 SCA E 1" = 30' ,H x 1"=3'V W LL to N �c0 4� d [p God �M rnM N wit") N� N CV nN W) N nl r"] � an CN N 1'� to cv ,�tV N N �N Ln N N �N LO N N CV �cV LO N N ,�N N N 1�r'j NLO N d �rj N N �r CN N N d '� ,mod N N d Ln N N d L0 N N 258 r- - -i-- _-.1---- -1258 EXISTING G OUND ) GRADE \ 252 -- r - _- 252 i J I STCB#1I, TYPE 1 STA: 11+86.!82 238.11' L RIM = 249. 6- -- --- -..- I.E. 12" (E) = 246.50 STC8#10, TYPE 2 - 48"0 STA: 12+59.83 265.27' L RIM = 252.00 240 __._L1:-42_--. (NW - 6.11- 240 I.E. 12" (E) 246.11 I.E. 12" (W) = 246.11 I.E. 12" {S = 246.11 STORM PIPE CENTERLINE PROPOSED GRADE SCALE I" = 30'!H EXISTING GROUND 1" = 3V 234234 . D O � d NN 258 252 246 240 EXISTING GR I GRADE � L r - STCB#5, TYPE 1 STA: 1 1+09.25 51.56' RIM = 1`249 90---�- I.E. 12' (E) = 24,630 ;TCa TYPE- 2-=-48 STA: 1 +48.72 71.81' L RIM = 252.23 I.E. 2" (W) = 245.9,,9 I.E. 2" (N) = 245.99 a � STORM 6 - - INTERLINE PIPE C - � p SCALE 1"= 30' H i L0 ji Q_ 1 " = 3' V Q 234 0) Cri a a d p N N CNN CNN N N ("A N m9A EXISTING GROUN PROPOSED GRADE - - 252 252 86 LF 12" ADS N-12 DS N-12 1.4% g1 12 Nqo STCB#15, TYPE I ��P 5 STA. 14+95.57 311.99' L STCB#14, TYPE 1 IRE. 12IM ' (E) 250.$2 246 246 63 AD .. _12 _ _ . 1252 962. 344.48' 1._ . , - 0.$2 12" RIM •21% I.E. 12 (E) = 249.50 I.E. %2" (SW) = 249'150 TC8#13, TYPE I STA: 12+16.14 10.02' L --RIM = 251.14 �.E. 12" (NE) = 247.50 .E. 12" (SE) = 247.50 STCB#10, TYPE 2 � - 48"O STORA-- 4 24a Sfik 12+59.83 2fi5.27' = 252.00 r_ � n _. _... RIM oc r�R �+E1Y 1 I.E. 12" (NW) = 246.11 GRLr�YE I.lr. 12" (E) = 246.11 CALE 1 = 30 H I.E. 12" (W) = 2416.11 1" = 3' V I.E. 12" (S) = 246.11 x Cr 234 258 252 f 246 240 STC6#2, TYPE 2 - 60"0 Ft OW SPLITTER PER DETAIL ON SHEET 5 1.�. 12" (E) = 244.80 I.E. 12" (S) = 244.80 I.E. 12" (N) = 244.80 I.F. 18" (W) = 245.24 LE 8" (NW) = 244.50 234 00 CN N nl N w cL 237 C3-)`-r�rn aN �N NnjCV„ 1-cl�n NN NNNc�v N NN N� 258 EXISTING PROPOSED GRADE 252 246 258 252 STC8#16, TYPE 1 STA: 15+72.88 274.55' L RIM = 254.47 I.E. 12" (W) = 251.25 vz,9, 237 to LO LO LO LO N N N N N N N N CNN 1 N N N 258 252 246 3TCB#6, TYPE 2 - 48"i0_ . _ _. _ -- S CB#7, TYPE 1 STA: 14+98.51 48.00' I,L S A: 15+33.74 48.00' L RIM = 250.04 R M = 249.40 I.E. 12" (S) = 245.66 I.E. 12" (SW) = 246.00 I.E. 12" (NE) = 245.66 35 L 7 1 " ADS N-12 ® 0.97% I.E. 12" (W) = 245.666 240 240 STORM PIPE CENTERLINE SCALE 1 = 30' PROPOSED GRAVE 1" = 3' V EXISTING GROUND ' 234 ' 234 c.C7 Know what's below. Call before you dig. NOTE: THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER APPROVAL DATE. THE CITY WILL NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX-XXXXXX-XX APPROVED DATE 0 z 01-1 OQ1rn C ono -00 ... W to �C M O LO N c s� 1 C.LJ 0 to ° I U� N U z Q Qca o � U CO aI� w� Q cc.z 02�� c\1 cL z Q C W Z J W I- J U DATE SEALED d- L z Z %, JE<</ C�Pe� OF WASy/SOS 40382 NALRE�G\� PROJECT MANAGER COLLEEN HARMS DESIGN GJ DRAWN SAJ CHECKED G J SEC 24 T R 4E FLE NO DATE OW/03/2022 SCALE f - 30' SHEET s OF4 FILE NO =72 ®APEX ENGINEERING LLC 2022 Of LO 0 4 M 256 252 248 244 240 GRAPHIC SCALE 20 0 10 20 40 ( IN FEET ) 1 inch = 20 ft. VERTICAL DATUM: NGVD 29 __ -- EXISTING GfZOUND PROPOSED GRADE q a a ° qa a n a I it i INFILTRATION AULT E SEE DETAIL, THIS! SHEET i I I '--- _ -- SECTION A A SCALE: 1" = 20' H 1"=2'V 256 256 252 252 248 248 244 244 240 240 PLANT 2 RELOCATION STORM VAULT DETAILS A PORTION OF THE SOUTH 1/2 OF THE S.E.1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M., CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON EL = 242.00 VAULT BOTTOM EXISTING GROLD r /"—T f f — PROPOSED GRADE; A 4 4 a d C V d e ,� 4 INFILTRATION VAULiT SEE �ETAII, THIS SHEET i SECTION B B SCALE: 1" = 20' H 1"= 2' V 256 252 248 244 256 252 248 244 240 236 252 248 244 240 236 240 2341 -� 234 SECTION C-C SCALE: I" = 20' H 1"=2'V Pk-% 248 244 240 236 234 EL = 242.00 VAULT BOTTOM TOP INSIDE VAULT ELEVATION = 248.00 VAULT BOTTOM ELEVATION AT WALL CORNER = 242.00 PRESETTLING VAULT 6E£ DETAIL, THIS SHEET a 4 a 256 252 248 244 240 4 a d e �.. - 236 - - — - - 234 SECTION D-D SCALE: 1 " = 20' H 1"= 2' V ACCESS MANHOLE W/ LADDER SUPPORT WALL (TYP) W/ ROUND SOLID COVER MARKED (SEE STRUCTURAL PLANS FOR "DRAIN" MTH LOCKING BOLTS (TYP.) EXACT DIMENSIONS AND LOCATION) L co 148' ACCESS MANHOLE W/ LADDER-1" U W/ ROUND SOLID COVER MARKED 18"0 VAULT WALL OPENING (TYP) "DRAIN" WITH LOCKING BOLTS (TYP.) INLET (SEE STRUCTURAL PLANS FOR EXACT DIMENSIONS AND LOCATION) 1' J FREEBOARD 18"0 INLET AX. � IN =1L TRA t1d)V DETAIL SCALE. 1" = 20' H 1" = 5' V ACCESS MANHOLE W/ LADDE EL 237.SQ R WIROUND SOLID COVER MARKEDEL 237.50 = "DRAIN" WITH LOCKING BOLTS TYP.) VAULT FLOOR VAULT FLOOR EL = 237.12 SLOE � 18"0 UTLET VAULT FLOOR V VALLEY � NE V OTTOM 18"0 INLET V SLOPE 63' V BOTTOM �I EL = 237.12 _ VAULT FLOOR EL -- 37 5a VAULT FLOOR 8„0 EL = 237.50 INLET VAULT FLOOR TOP INSIDE VAULT ELEVATION = 246.00 18"0 INLET VAULT BOTTOM ELEVATION AT WALL CORNER = 237. ` 18"0 OUTLET SEDIMENT STORAGE ELEVATION = 238.50 PRESETTLING VAULT DETAIL SCALE: 1 " = 20' H NOTES: 1. ALL METAL PARTS MUST BE CORROSION RESISTANT. STEEL PARTS MUST BE GLAVANIZED AND ASPHALT COATED (TREATMENT 1 OR BETTER). 2. PROVIDE WATER STOP AT ALL CAST -IN -PLACE CONSTRUCTION JOINTS. PRECAST VAULTS SHALL HAVE APPROVED RUBBER GASKET SYSTEM. 3. ALL DIMENSIONS SHOWN ARE INTERIOR DIMENSIONS NEEDED FOR VAULT OPERATION. REFER TO STRUCTURAL DESIGN PLANS. 4. THE VAULT SHALL NOT BE USED FOR STORMWATER DETENTION/RETENTION UNTIL THE WALLS HAVE BEEN BACKFTLLED TO THE FINISHED GRADE. 5. SIZES AND LOCATIONS OF ACCESSES AS SHOWN. ALL VAULT AREAS MUST BE WITHIN 50 FEET OF AN ACCESS POINT. 6. ENTRANCE TO CONFINED SPACE WILL BE CLEARLY MARKED AS REQUIRED BY OSHA. THIS MAY BE ACCOMPLISHED BY HANGING A REMOVABLE SIGN IN THE ACCESS RISERS JUST UNDER ACCESS GRATE. 7. VAULTS ARE NOT ALLOWED IN FILL SLOPES WITHOUT A GEOTECHNICAL STUDY FOR STABILITY. 8. REFER TO STRUCTURAL PLANS FOR LOADING REQUIREMENTS AND DESIGN CRITERIA. 9. FOR RAISED OPENINGS WHERE THE DEPTH FROM THE IRON COVER TO THE TOP OF THE VAULT EXCEEDS 24", AN ACCESS STRUCTURE EQUIVALENT TO A TYPE 2 CATCH BASIN OR TYPE 1 MANHOLE SHALL BE USED. 10. VAULT STRUCTURAL PLANS AND SPECIFICATIONS TO BE REVIEWED AND APPROVED UNDER A SEPARATE BUILDING PERMIT: VAULT SHALL MEET H2O STRUCTURAL LOAD REQUIREMENTS. EL = 242.00 VAULT BOTTOM EL = 242.00 VAULT BOTTOM DESIGN WATER SURFACE ELEVA7ON = 247,00 I.E. = 242.85 Know what's below. Call before you dig. NOTE: THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER APPROVAL DATE. THE CITY WILL. NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX—XXXXXX—XX APPROVED DATE QF rd o � rn � Nno • rn� Oi NOS 0� °D LO 'Cm o v 0 C' X LL v) o LL- 3 N E'It v 1 M LO N U � J O L� r � N Q� o U J Co J w zxQ COX:� N z C Q C a W Z J W I— J U DATE SEALED P1 Fb WAS,y�Sp ar 40382 rn� RFO t ST-RF'� SS/OVAL E� PFK JECT MANAGER COLLEEN HARMS Gj DRAWN 8AJ CHECKED 512 SEC 22 T 2IN R 44E FILE NO DATE 06/00�372022 SCALE r -W SHEET 7-OF 14 FILE NO 3W72 © APEX ENGINEERING LLC 2022 PLANT 2 RELOCATION 816-2-CPS Projected Coalescing Plate Area - 2.368 SgYt. "Design flow Rote = 5+60 GPM (see brick page) Maximum Process Flow - 1,508 CPM TOP No. 816-T-CPS FuH 180• open 14,970 lbs. (Typical) (4) 8 Ton Lilt Anchors Suitable for use in off-street locations where not subjected to high -density traffic Pull 180' Open Risers as Required'-� Nc, 57--6-•T-2-332P -� a . 1,645 lbs. Risers as Required V-1" Note: Designed for 0 to 5'-0" of Cow 816-2-CPS Okkmsft Precast"0 File -Na> :_a2o6ascPs PO Box 323, Wilsonville, Oregon 97070-0323 Issue Date: 2018� Tel. (503) 682-2� 4£#4 Fax: (Bt13) 682-2657 oldeastleprecaSt.corrdw 11.0 816-2-CPS Notes: - 816-CPS is avglfts t sot up for future instailat€on of coalescing media and designated as 816r-CPS-R - Customer is responsibtp for supplying crone to set and assemble vault. 816-2-CPS OIL I WATER SEPARATOR _ COALESCING - 560 GPM e Projected Coalescing Plate Area - 2.368 Sq.Ft. 'Design Flow Rate - 560 GPM Maximum Process now w 1,508 WM 18'-11" No. 2-,3.32P - Spring Assisted Galvanized Mamond Plate 2'-8- „��.., 4,_8" ._.,�. 2'-8 (2) - No- 24UP Doors wfto[Jcinj Latch I r GolvanlXed Dl�nond Plate Doors — — T w/LockIng Latch ! / I e � A ! ! . A' L— — — — - — — — — --- -- (4j 8-Ton Llfl Anchors 2'-2' 6'-3f 6'_3 ' 2' 2. PLAN VIEW Line Gal Retolning Baffle 2'-0' x Y-O" Blackout Hoid-Down to- PVC INLET PIPE (iypltaU for Coalescing Media w/T'ee PS: 10' PVC OUTLET PPE 4'W2. x 6'-6" OPTIONAL TO w/Sompling Tee SIoc1 tiu! 2'-9' and Y--9" Heights 9.utyl Resin Sealant Risers os 6Required •' �° �w E Sed'ement wear ' in alo 90 o e5 I o i era SO �[� N 43 IX Jlva Coalescing Media 8-Ton Lift Anchor (2 Each End) 4'-4J" n SECTION AA *DESIGN 10= agaic Design Informoti= " FLOW EFFLUENT MLI;CTED Influent Characterlcs - OM Specific'iWovity - 0.88 RATE QUALITYzE - Operating Temperature a 30' lO Win 60Micron - Influent Oil Concentrotion - 100 ppm 560 GPM - Mleon Oil Droplet Size - 130 Microns Notes: - 033 ft/min. Critical 01 Droplet Predicted Rime Rate - Static Water Depth - 4'-0` - Prior to 'Startup" of system, fill with clean water *Basic Design information per Washington to bottom of outlet pipe. Cor best results, fill to flow line. State Deportment of Ecology, User to A4lust - Fagow Regular Inspection, Cieonin% & 1Maintenunse Estimates for Variations n Reol Conditions. 5cfleduW (S" Clean Out At Mointenanoe� 816-2-CPS 816-2-CPS OkkmsMe Prt* — . ----------_. OIL / WATER SEPARATOR FIaB 1+Eamal: d12"16CPS2 PO Sax 323. Wilsonville. Oregon 97070-0323 Issue pate: 2018 -- COALESCING - 560 GPM Tel (503) 682 2844 Fax: (503) 682-2667 oldcastleprecafist.Corwwilsonvilre STORM NOTES AND DETAILS A PORTION OF THE SOUTH 11/2 OF THE S.E. 1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M., CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON INLET WIN00W 17'-0' 018" RCP MAX. INLET ALTERNATE INLET LOCATION t— --------------------------- - � INLET I I �wrswn' � 3! ! 1 ---�. r....— -- _n f yf' I oUT1 ET ! -----------._.... _—.._—..._.. _—...._— J ALTERNATE OUTLET LOCATION I � 1 €3rVIDER WALL 018" RCP MAX., OUTLET PLAN VIEW 2X 024" BOLTED & GASKETED ACCESS COVERS, FIELD POURED CONCRETE COLLAR REQUIRED. BY OTHERS. ...1_— I ! I ! I ------------ --- —L 4,1p" 11 INLET ��� 1! 2'-2" [26"1 DROP RECOMMENDED, 6- RAIN. I! 15" OPTIONAL DRAIN DOWN DEVICE 4" LEFT END VIEW 2X 036" BOLTED & GASKETED ACCESS COMERS, FIELD POURED CONCRETE COLLAR REQUIRED, BY OTHERS. I RIM 4" MIN TO 5' MAX COVER (SEE NOTE 12) 6-1-1/4'MIN — — — — — -- — — - — — — — — ENERGY DISSIPATION 13=10" MAX II - I STONE 2 " MULCH DIVIDER WALL 2 I BYPASS WEIR StOrrrlMs�f"" MEDIA OUTLET L6" DRAIN ROCK UNDERDRAIN PIPE ELEVATION VIEW �x;relA��?aNY (�sR;^nr�ut 1- DESIGNLOADINGS5 A. AASHTO HS•20.44 (MTN IMPACT) s. DESIGN SOIL COVER: 5'..17 MAXIMUM C. ASSUMED WATER TABLE: BELOW BATE OF PRECAST (ENGINEER -OF -RECORD TO CONFMA SITE WATER TABLE EL! VATION) Q. LATERAL EARTH PRESSURE: 46 PCF (t}RAINCO) E. LATERAL LIVE LOAD SURCH.ARGC: lid PSF (APPLIED, TO f1'0 BELOW GRADE) F. NO LATERAL SURCHARGC FROM ADJACENT BUILDINGS, WALLS, PIERS, OR FOUNDATIONS. 2. COUCREiE 28-DAY MINIMUM COMPRESSWE STRENGTH: 500 PSI MINIMUM. 3. REINFORCING: REEIAR, ASTM ASIIWA106, GF6ADE 60 4. CEMENT. ASTM C i So 5. REQUIRED ALLOWABLE SOIL SEARING CAPACITY: 2,WO PSF 6 REFERENCE STANDARD: A. ASTM C890 €3, ASTM M 3 C. AGI318.14 7. THIS STRUCTURE ig DESIGNED TO THE PARAME'i1 AS NOTED HEREIN. ENGNEER-OF-RECORD SHALL VERIFY FY THAT NOTED PARAMMRS MEET" OR EXCEED PROJECT REOUIREMENTS. If DESIGN PARAMETER: ARE INCORRECT, REVIEWING ENCUNIZER)AUTHORITY SHALL NOTIFY OLDCASTLE INFRASTRUCTURE UPON REVIEW S. INLET AND OUTLET 14OLES WILL BE FACTORY COREDiCA$T PER PANS AND CUSTOMER REOUIREMENTS- INLET AND OUTLET LOCATIONS CAN BE MIRRORED. s. CONTRACTOR M$PONSSLIE TO VERIFY ALL St2E3. LOCATIONS, AND ELEVATIONS OF OPENINGS. 10. CONTRACTOR RESPONSIBLE TO ENSURE ADEQUATE SEARING SURFACE IS PROVIDED (LE. COMPACTED AND LEVEL PER PROJECT SPECIFICATIONS). 111. :SECTION HEIGHTS, SLA8141'ALA THICKNESSES AND KEYWAYS ARE SUBJECT TO CHANGE AS REQUIRED FOR SITE REOUlREMENTS ANDIOR DUE TO PRODUCT AVAILABILITY AND PRODUCTION FACILITY CONSTRAINTS. 12. MAXIMUM PICK W+EIGY3T9': A. TOP- XX,XXX LBS S. BASE.: XX,XXX LSS" (` COMNED WEIGHT OF BASE )INCLUDES BYPASS WEIR. DIVIDER WALL, ROOK A MEDIA) 13. INTE:RIUALS SHALLCONSIST OF UNDERDt2A€N PIPE, ROCK. 9'TORNIMIX"" MEDIA, MULCH. DVIDER WALL, BYPASS WEIR AND OPTIONAL DRAIN DOWN. Know what's below. CaII before you dig. NOTE: THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER APPROVAL DATE. THE CITY WILL NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX—XXXXXX—XX APPROVED DATE a d olT onco � Nn0 • }' t7) iV) 0to K) O N c Lit 0 fA LL fl N is ao' 0 C) I to N U v co J O V 0 CA '~ OQ C W co J: X _ act N z t= a C Q W Z J W F- J F_ U DATE SEALED d-9--z 5A'.JELZIWA � !� 40382CIS S�ONALR���\� PROJECT MANMWR 0Oi1S31V HAPoRIS DESM GJ DRAWN W CHECKED GJ SEC 20 T 28N R 4E FIE NO DATE OOLOS1 SALE AS NOTED SHEET 8 OF4 FUE NO =72 © APEX ENGINEERING LLC 2022 GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) 1 inch = 30 ft. VERTICAL DATUM: NGVD 29 4 LF 12" ADS N-12 ® 10.00% © STCB#19, TYPE 2 - 48"0 W/ SOLID LOCKING LID J STA: 10+80.78, 27.55' L SAWCUT AND SEAL EDGE 15 STCB#18, TYPE 1 STA: 10+91.20, 23.3 L 46 LF 12" ADS N-12 ® 0%---.,, 15 STCB#17 1 STA: 10+72.65 19. ' R STA: 10+00.00 10 0 q INTERSEC71ON _ _ - PACIFIC HWY Sj S. 351ST STREET -- SD -SD --SD- SD- D SD---SD--SD- 258 R14YA GRADE BREAI 240 46 LF 234 228 P*bl .d PLANT 2 RELOCATION S. 351ST ST. PRIVATE ROAD PLAN AND PROFILE A PORTION OF THE SOUTH 1/2 OF THE S.E.1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M., CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON a ���/./,� .,u�°� yy�I' yd-- . a `I � _.-}°'a�.� ' ° �y/ `. �a , ❑ °. a� I Id.a, a / a- .° / qa ad a '�aa'®i �I, .a aa a° ad aa �° .' a 'da.sa °. aq,. aIl�a' t� dq .d ',avI�jr/ / /'r//Jp�-JI�11I'��• _- a °._- a'd_ ' m.,I;.,4 . as°- ..d°..,a_ e d ads _ -a a aa_, ....... '� \Sa STA: D 15+3� 42p� 20.50 (L) (BACK OF CURB) m/ °d INSTALL 45'1 WIDE COMMERCIAL a e d DRIVEWAY APPROACH PER aa a,4 CITY OF FEDERAL WAY STD DWG NO. 3-6A da G dteSrA: 15+68.42 im y d ASD�FULL ROAD IMPROVEMENTS } I1541 (PAVING, CURB, GUTTER, AND SIDEWALK) a dO a n � a 4 l. _f e a _ -a`� •`. � � a a , , d a - e c a a - d - .a - a °' � � .. � . a \ V ;� -�'' Uj a a n a a d a c ae d SD- ❑ p. \ r'� � � 2 �.-.- SQ _.r i d- d ' s da �F STA: °19+0 .03 'A ) ° � 4� a a f CENTER bl ►�1 N'S `-_ S SD` 'r w Q 4STAJf�-OF,#�TURN- +64.955 00'(RQCEN SD 2'221 329.04' \ e� 5 i �� s_, e' I �� N6`'�✓gip 3 STCB#8, TYPE 119 STA: 14+77.88,119.16' L _ 38 LF 12 D.I. @ 0, 50% I -. 4 ..,,. s�' 4s� STCB#9 TYPE 1 15 STA: 14+ 77.88, 19,16' R i 3 SS - D.- -77SID--SID SD _ ,� . STA: 14+28,29, 20.50'(R) (BACK OF CURB) --.. s INSTALL 30' WIDE COMMERCIAL DRIVEWAY i -- - _ - - �o APPROACH PER CITY OF FEDERAL WAY STD DWG NO. 3-6A I i° I � I NIGH PT. STA 13+14.45 L W Pr. STA = 1 +77.88 I HIGH PT ELEV = 250.73 OW PT ELEV = 248.61 0 PVI STA = 1 +85.00 �PVI STA = 14+60.00 PVI ELEV = 251.69 PVI ELEV = 248.25 + u' A.D. = -6.97% I A.D. = 2.96 K - 1_9.38 135 VC ... - -J_- 37.1 - - - - 110' VC co L LI o DWY 'mC " n. DWAY � w IIU' Lo Go �I _... N CN r .a •.� - ` tC) N j Q 0 L� LEI ME. LOW Pr. 5 A - 10+72.65 cii m -- ,- n m m (I c"'> > I W z � LOW PT ELEV = 241.69 y PW STA '= 10+82.64 E ISTfNG CROIJND � m - -PVI ELEV = 24156 A.D. ^ 6.007. PROPO E GRADE K - 5.00 R/W 30' VC III I I I 14 ! II -- ... .. CADS- _ ON o�`! ��� III III I 1 I I IIII IIII ULijLU I 1 ca B10POD BIOFILTER Q III II I 5 STCB#9, TYP 1 I I I I III STA = 1 0+48.96 MODEL BPU=, 461B I I I 11 I STA: 114+77.88 19.16'. R I I I I I I I I ELEV = 1 241.90 f II I' I ' I I I.E. 12" (E) � 237.50 I II I II I II " RIM = 248 21 I I I i III I MATCH _ EXISTING . _ _.... - IIII I _.LE. 12" (W)=_23.7.00_.__ __ _ .- It��rt I I.E. 1 (NW) = 246. I I I I .. IIII III II II 111 I 38 �F I I I I IIII 12" D.I. II I I II III I it it EXISTING STORM I II II 1 ® 0.50 I I I I 12" ADS N 12 0.50% I I 1 11 II STC13118, TYPE 10 I I I I it it STA._1 RIB! = 2,230 9120.23:30' L- I i Jill _ 1:E. 12" �SW) _= 237.8 _ _. _ I I.E. 12" 'NW) = 237.87 III I I I I II 3 LF ? ADS N-12 0 12.327 - - - - - - - r - -- - - III II I STCB#8, TYPta 1 I I I I IIII -- - - _ - - _- STA: 14+77.88 19.16' I1 11 I� _ - III III RIM = 24821 I ( I I I I 4 LF 12ADS N-12 ® 10,OOX SEWER I.E. 12" (SE) = 245..8 I.E. ;12" (N) = 245.64 1 1 I I I I I 11 II STCB 19, TYP 2 - 48"0 W SOLID LOCKING LID t6 � o EXISTING SANITARY ! i t II II I STA: 10+80.78 27.55' L I I I RIM = 242.64 - S I -- U I.E._ 12" SE = 236.60 ..._ _TE - fO (N, S) - 236.5i (EAS _-- NO - - - - - _ SAS V�JIS 1 ! - - 10fO* TO S 16f7 � w u L L_1 STCB#17, _ TYPE 1 15 n STA: � 10+72.65 19.''16 R SCALE. � = 30$ H � v o RIM = 241.28 1 " = 3' V c O I.E.I 12" (NE) = 23:8.10 I w �- p m cv 00 . �j- I� In � Cb M eo rF O M rn �t 0) rn^ fl0 0) n 00 cn to `- d eF N m 00 M N N � to Cfl O L O LO � N tc ) N cy dN cv* " d� c�I� ' � d� cy`� N Ltd- [v � d cv� ^ � evd 0ppp � . � t) O O � CV ci O LO mod' d7 Qi �d � 07 �F� 06 a� d pp c3i �� 6> CSC d � 6� ��f � -4- N N F N N N N� N N N N N N N N N N N N N N N N N N N N N N N 10+00 10+20 10+80 11+40 12+00 12+60 13+20 13+80 14+40 15+00 15+60 258 252 246 240 234 228 225 16+07.27 COAb1 RWT M NOTES EXISTING UTILITY POLE TO REMAIN, PROTECT DURING CONSTRUCTION 20 EXISTING CATCH BASIN TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST TO FINISH GRADE AS NECESSARY 3� EXISTING SANITARY SEWER TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST TO FINISH GRADE AS NECESSARY. CONTRACTOR TO COORDINATE WITH LAKEHAVEN WATER AND SEWER DISTRICT AS NECESSARY ® EXISTING WATER VALVE TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST TO FINISH GRADE AS NECESSARY. CONTRACTOR TO COORDINATE WITH LAKEHAVEN WATER AND SEWER DISTRICT AS NECESSARY 0 EXISTING GAS VALVE TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST TO FINISH GRADE AS NECESSARY. CONTRACTOR TO COORDINATE WITH PUGET SOUND ENERGY AS NECESSARY. © EXISTING WATER METER TO REMAIN, PROTECT DURING CONSTRUCTION. CONTRACTOR TO COORDINATE WITH LAKEHAVEN WATER AND SEWER DISTRICT AS NECESSARY Q EXISTING UTILITY POLE TO BE RELOCATED, CONTRACTOR TO COORDINATE WITH PUGET SOUND ENERGY AS NECESSARY ® EXISTING FENCE TO REMAIN, PROTECT DURING CONSTRUCTION ®EXISTING FENCE TO BE RELOCATED, COORDINATE WITH ADJACENT PROPERTY OWNER AS NECESSARY OEXISTING UTILITY VAULT TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST TO FINISH GRADE AS NECESSARY. CONTRACTOR TO COORDINATE WITH PUGET SOUND ENERGY AS NECESSARY. NEW ASPHALT TO CONNECT TO EXISTING PAVEMENT FOR THE CROSSINGS COMMERCIAL DEVELOPMENT, COORDINATE WITH ADJACENT PROPERTY OWNER AS NECESSARY ©SEE GRADING DETAIL ON SHEET 10 1Q 1310POD BIOALTER MODEL BPU-46IB RIM = 242.46 (CENTER OF VAULT) I.E. IN 12" (E) = 237.50 I.E. OUT 12" (W) = 237.00 SEE DETAIL ON SHEET 12 14 INSTALL TYPE III BARRICADE AT THE END OF WALK PER CITY OF FEDERAL WAY STD DWG NO. 3-15, O INSTALL THROUGH -CURB INLET AND 81--DIRECTIONAL VANED GRATE PER CITY OF FEDERAL WAY STD DWGS 4--8, 4-9, AND 4-10A 9INSTALL OVER EXISTING STORM PIPE. CONTRACTOR TO VERIFY LOCATION, INVERT, AND PIPE TYPE PRIOR TO CONSTRUCTION Know what's below. Call before you dig. NOTE: THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER APPROVAL DATE. THE CITY WILL NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX--XXXXXX--XX APPROVED DATE 0 v� N"t" i o d 00 CLO Cp LO N _ CID \\\ 0 U l N v 3 m prn `-4 E LO ri N .J Z 00 �7 P Cc O OW ED4 wLA � x < CC N �- U O Z 4.- 0- Q Cn NJ F- W Z J W F- J 1-- 10 DATE SEALED 9-ZZ PgF-o w a Sy/SO 40382 �F �F- / T SSIONM_ E.N PROJECT MANAGER COLUOY HAS DEEM OJ DRAWN SAJ CHECK CJJ SEC 20 T 2>N R 4E FLE NO DATE 06=72022 SCALE 'r - 30' SHEET 9-OF 11 FLE NO 3W72 ©APEX ENGINEERING LLC 2022 0 L0 r- C) 0 Ln N h L0 GRAPHIC SCALE 5 0 2.5 5 10 { IN FEET ) I inch = 5 ft. VERTICAL DATUM: NGVD 29 ❑1 T ST. / 35.00' 41.89' B 3,03" c%4 N Q 241.38 d A Q 241 S. 361ST $T. . 6.w 241 9 e a �5 a 0 419n 9� PLANT 2 RELOCATION 351ST PRIVATE ROAD DETAILS A PORTION OF THE SOUTH 1/2 OF THE S.E. 1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M., CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON I z FAI Know what's below. NOTE: Call before you dig. THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER APPROVAL DATE. THE CITY WILL NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX—XXXXXX—XX APPROVED DATE a 0 z E o� O O_ ac o°'CD v� NItLO r- v Oi a° .0 LO 1n p N %rir, O L Q r3 N E 0 , Uri H � N u U z� O� a ID , Q N OQ �Ncm W xa cc U�3� z �. Q 4L a F- W Z J W F- J U DATE SEALED /- 2- Z WASy�s0 A` 2 0 ro 0 40382GIST 4. /ONA1 PROJECT MANAGER COLLEEN HARMS DEEM G J DRAWN SAJ CHECK GJ SEC 20 T 2W R 4E FILE NO DATE QLL. SCALE E ' 5' SHEET Lo OF 14 RX NO =72 9 APEX ENGINEERING LLC 2022 z FAI Know what's below. NOTE: Call before you dig. THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER APPROVAL DATE. THE CITY WILL NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX—XXXXXX—XX APPROVED DATE a 0 z E o� O O_ ac o°'CD v� NItLO r- v Oi a° .0 LO 1n p N %rir, O L Q r3 N E 0 , Uri H � N u U z� O� a ID , Q N OQ �Ncm W xa cc U�3� z �. Q 4L a F- W Z J W F- J U DATE SEALED /- 2- Z WASy�s0 A` 2 0 ro 0 40382GIST 4. /ONA1 PROJECT MANAGER COLLEEN HARMS DEEM G J DRAWN SAJ CHECK GJ SEC 20 T 2W R 4E FILE NO DATE QLL. SCALE E ' 5' SHEET Lo OF 14 RX NO =72 9 APEX ENGINEERING LLC 2022 4 I A A A A ZE dir > a IN D J � (A- \ A > n ' I -d NEW ENTRANCE SEE DETAIL AT RIi I I I PLANT 2 RELOCATION PACIFIC HWY SOUTH IMPROVEMENTS A PORTION OF THE SOUTH 1/2 OF THE S.E. 1/4 OF SEC71ON 20, T0IWNSHIP 21 NORTH, RANGE 4 EAST, W.M., CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON G GRAPHIC SCALE 20 0 10 20 40 { IN FEET } 1 inch = 20 ft. VERTICAL DATUM: NGVD 29 PLAN NOTES Q EXISTING UTILITY POLE TO REMAIN, PROTECT DURING C0NSTRUC77ON 0 EXISTING CATCH BASIN TO REMAIN, PROTECT DURING CONSTRUCTION AND ADJUST TO FINISH GRADE AS NECESSARY A REMOVE EXISTING DRIVEWAY APPROACH. REPLACE WITH NEW CURB AND GUTTER PER CITY OF FEDERAL WAY STD DWG NO 3-4A, 5.5' LANDSCAPE STRIP, AND 8' SIDEWALK, MATCHING EXISTING. ® SAWCUT MIN f FROM EDGE OF PAVEMENT AND SEAL EDGE. A EXISTING LIGHT POLE TO BE RELOCATED, CONTRACTOR TO COORDINATE WITH PUGET SOUND ENERGY, WSDOT, AND CITY OF FEDERAL WAY AS NECESSARY ® EXISTING WATER METER TO REMAIN, PROTECT DURING CONSTRUCTION P GRAPHIC SCALE 20 0 10 20 40 ( IN FEET ) 1 inch = 20 ft. VERTICAL DATUM: NGVD 29 Know what's below. Call before you dig. NOTE: THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER APPROVAL DATE. THE CITY WILL NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX—XXXXXX—XX APPROVED DATE PLANT 2 RELOCATION ROAD AND STORM DETAILS ■ F. A POR71ON OF THE SOUTH 1/2 OF THE S.E. 1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M., CITY OF FEDERAL WAY, KING COUNTY, WASHINGTON CROSS SECTION TYPE R 2 LANES + PARKING s 3' 6' 4' * 8' 12' 12' 8' 4' * 6' 39 U111 c Parking Parking o a U111. Strip # Strip 40' 6 6' MINIMUM PAVEMENT SECTIQNS MINQR CQLLECTOR LOCAL (RESIDENTIAL) 0.25' HMA Xi". PG 5SH-22 0.25' HMA Y2", PG 58H-22 0.17' CSTC 0.17' CSTC 0.50' CSBC 0,42' CSBC NOTES: 1) SUBBASE TO BE BANK RUN AS NECESSARY TO STABILIZE PAVEMENT PLANTER STRIP DIMENSION IS MEASURED FROM THE SIDEWALK TO THE FACE OF CURB. AEV: MAP 2049 Wo KS COLLECTOR/LOCAL D3 WG2RO LO n I N n O ru VARIES INLET WINDOW 4 -0" INLET 2`-2" (261 DROP RECOMMENDED, 6" MIN. 0� 6" OPTIONAL DRAIN -� DOWN DEVICE LEFT END VIEW 012" RCP MAX. INLET ALTERNATE INLET LOCATION �—=► INLET ti 5''0" 4''0" �.� OUTLET ALTERNATE OUTLET LOCATION 012" RCP MAX. OUTLET 2X 013" TRAFFIC RATED CAST IRON COVERS, FIELD POURED CONCRETE COLLAR REQUIRED, BY OTHERS. 5'-1-1 13%10" MAX III r"G. DIVIDER WALL PLAN VIEW 036' BOLTED & GASKETED ACCESS COVER, FIELD POURED CONCRETE COLLAR REQUIRED, BY OTHERS. JE RIM 4" MIN TO 5' MAX COVER (SEE NOTE 1.B) I ENERGY DISSIPATION STONE 2" I I -MULCH X-10" I ]ER WALL I I BYPASS WEIR 1 StormMIxTm MEDIA 6" DRAIN ROCK 1' 6' UNDERDRAIN PIPE ELEVATION VIEW NOTES; 1, DESIGN LOADINGS; A. AASHTO HS44-44 (MTH IMPACT) B. DESIGN SOIL COVER: 6410 MAXIMUM C. ASSUMED WATER TABLE: BELOW BASE OF PRECAST (ENGINEER -OF -RECORD TO CONFIRM SrfE WATER TABLE ELEVATION) D. LATERAL EARTH PRESSURE: 45 PCF (DRAINED) E. LATERAL LIVE LOAD SURCHARGE: 80 PSr (APPLIED TO 8'-0' BELOW GRADE) F. NO LATERAL SURCHARGE FROM ADJACENT BUILDINGS, WALLS. PIERS, OR FOUNDATIONS. 2, CONCRETE 28-DAY MINIMUM COMPRESSIVE STRENGTH; 5,00D PSI MINIMUM. 3. REINFORCING: REBAR, ASTM A6MA706, GRADE 60 4. CEMENT: ASTM C150 5. REOUIRED ALLOWABLE SOIL SEARING CAPACITY: 2.500 PSF 6. REFERENCE STANDARD- A ASTM C890 E. ASTM CM C. AC1318-14 7. THIS STRUCTURE IS DESIGNEE) TO THE PARAMETERS NOTED HEREIN. ENGINEER -OF -RECORD SHALL VERIFY FY THAr NOTED PARAMETERS MEET OR EXCEED PROJECT REQUIREMENTS. IF DESIGN PARAMETERS ARE INCORRECT, REVIEWING ENGINEEPJAUTHORITY SHALL NOTIFY OLDCASTLE INFRASTRUCTURE UPON REVIEW. 8. INLET AND OUTLET HOLES WILL BE FACTORY CORI7DICAST PER PLANS AND CUSTOMER REQUIREMENTS. INLET AND OUTLET LOCATIONS CAN BE MIRRORED. 9• CONTRACTOR RESPONSIBLE TO VERIFY ALL VMS, LOCATIONS, AND ELEVATIONS OF OPENINGS. 10. CONTRACTOR RESPONSIBLE TO ENSURE ADEQUATE BEARING SURFACE IS PROVIDED {I.E. COMPACTED AND LEVEL PER PROJECT SPECIFICATIONS), 11, SECTION HEIGHTS, SLABIWALL THICKNESSES, AND KEYWAYS ARE SUBJECT TO CHANGE AS REQUIRED FOR SITE REQUIREMENTS ANMOR DUE TO PRODUCT AVAILABILITY AND PRODUCTION FACILITY CONSTRAINTS. 12. MAXIMUM PICK WEIGHTS": A. TOP: XK)O(X LBS B- BASE XX.XXX LBS" (' COMBNNED WEIGHT OF BASE INCLUDES BYPASS WEIR. DIVIDER WALL. ROCK & MEDIA) 13. INTERNALS SHALL CONSIST OF UNDERORAIN PIPE, ROCK. STORMMIXm MEDIA. MULCH. DIVIDER WALL, BYPASS WEIR AND OPTIONAL DRAIN DOWN. Lj Know what's below. Call before you dig. NOTE: THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER APPROVAL DATE. THE CITY WILL NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX—XXXXXX—XX APPROVED DATE 4 0 z E 0 0 Oil O M 0) mc p7 Nr11r-o 7LC1ln 00 p7 te) o C14 ► . j C X (0 l¢� �3 O d N E O � 1 M to In N v U Jo O_j Y �` Q h to Q� O a(0 (� (0 d' �cc aRv ..J � x w� � x�� cc U NzrL ~o Z 0L O a l— W Z J W J U DATE SEALED Z- 9--zZ_ W A S,,l 4 40382 <cI RFCI STERF° Ss/ONAL PROJECT MANAC ER COLLEEN HAS DESM G1j DRAWN SAJ CHECKED GJ SEC 20 T 21N R 4E FILE NO DATE 06/03/2= SCALE AS NOTED SHEET L2OF 14 (FILE NO 3W72 © APEX ENGINEERING LLC 2022 I GRAPHIC SCALE PLANT 2 RELOCATION 30 0 15 30 60 UTIL" PLAN ( IN FEET) 1 inch = 30 ft. A PORTION OF THE SOUTH 1/2 OF THE S.E. 1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANGE 4 EAST, Wm., VERTICAL DATUM: NGVD 29 CRY OF FEDERAL WAY, DING COUNTY, WASHINGTON r ' Ii 4 a d a d 4 4 n k d n wl a 4 ad a 61 a e,a e a 4 ad a °4 ao / /.. ❑. 4 q a a a tl❑ a a a a a ° a 4 // '° 4 a 4 a d 4 r a. a a 4 ❑ 4 a s a a ❑ 4�0 4 /4 y n 4 NEW WATER SERVICE ❑° a d a 4 a 4 a s 1 a s 6 ❑ A d d a d a 4 a 4 4 v 4 a4. CONNECT TO EXISTING METER a a ❑ a ' 4 °e ❑ 1a -- 4 a d ° . m a q 4 4 a t -° 4, ' W CONTRACTOR TO COORDINATE �f 4`'Y " a a a ° do a e d d a a ❑ a a as Q4 WITH UTILITY PROVIDER �! a 44a a ❑ I� 4a d f L 4 p q a tl a a a a ° d e� 6 I !� • 4 a / 4❑ d a' d a s /{ a 'A 44 d ¢ d' a f 6 q A tl p :6: tl a a � e a a s e❑ a a d G d a�a d . � °d d 'a '4 a � � ❑• a q.. ' / a d 4 � � @ -.d a � d❑. .q 4. ay bna � S�� �' /j// I �/r V///` �� �(/jf/�,/ �fI/� ` /I � / �/ / � / 1 y�p "�. '�� Ajiy+%y If�drf! / III/ . r / I6/ / °///l /Q r / .ada / _ _ 1N u a/saa ':aad0a ad/// -a �8 "a' J/❑. ' I Gdd, ./ A /aa 4 / / 4.a/�❑,a </ �. d4 \a!/ti /_ da4°(4 a I /. �/Qa q� /�, d q . 4a�ddabl°/ f4 �a ❑dJ`�/ ' a�fr e a°.� 4 a ❑, qsa ❑ ❑n/a 4 qaa4e e aa a a4 d A a daa �d < d °dd 4 a4a°d s dq°/ da . a aaI d aaf 4 a4.aen �q '�_ d .a ❑ �a a .a4 n � a a4a,a d a4�a a4 qm .a .Aaaa d a aa,- a d❑4❑ee - a dq4 oaa 4a.d` daad4Q.a ed¢4 °d a'a ad❑4 7aa dO❑da daad . eb aaa da❑a dd a aaaad , s ad aG adae. a 4ad ❑ a aa4 aq d 4 ' a� ❑ ° ❑ d..a 4d d4-0 q. adanq.❑a , ❑4aqtl _dd ,�a ' a�a . d,4Aa a d'4dn d4 o d q 4a'0 a m a tq df° 'v da a da a.a❑ V a°ddd . ❑.a a 4qa_ d a ataLLa d$a a a ❑.dd a d ❑ a �d an asa°a e da4 ,d A a a ❑aaaaa ad 'a® ❑d 4° 4 a -a� °4 a m dsd6a41a q e.m aa a❑s°d 4a a m sad °a_ a °a6 �. e ,.❑� a4da aadQ ❑❑:tSd ° aaa au 4a °4 a da °. 4d a°a.d d A °°a °4 4G a d �. . A. a da° j d ❑ dd md ° aa d 4d .a a++q daaa ° n ada � 6❑q.aq aata !aaa4d- . ° a 4n° 4 a-4d �a4� ed❑aap 4 - . da a°w 4m a dd.aa a a -1a °ad❑4 aa ea-0a qQa a.4°4 a a a ❑ a a a d--e�,❑-te ra°..y°s^a"aaAa.�4 ❑.d ° a a ca a -4n aa,dxad1a a - 4 ra ad " a �d'a3a 6''a .a °a dA,4°a edaSa _ ,ad4d ; - a.4.d—- s�a.� ��❑11xid' — aaa4°44 ' ❑ _.d _ d _�_� c❑ )°t44 �S� o .4 dm ' ✓ a d.9 .n ❑ , 4 ." eaa� r4 Ya4a �ayaa a .d❑ �(#s�f�a %._. id .a��dVV 11I �e 4d,,.G,lId..I4�q � . c{�aa5-q� a ❑a�D ❑.❑�tl'❑;. °�dq' d � ra�ad❑q�, . s .d 4d �a bae❑ d eGaQ A 4d a 4 A. d a 4 e s 4 4 ° a ❑ a ._-g4•d yag .�d � e 4qa. � aA✓ a❑a a���a a' } •d p q•b °°d4 - d44 ;a $ I�fI fJ (-.SOCI:I`kf'I JI 7 =I 1. yIII=.1 kb� � ,7 a TPN 18~52_ 95II 0. �01�0 A A °e4 d ❑4 44 A e 4p y 4 d ❑ ,a a ° a 4 d 4d 1:3 aa A d4 q a A s � aq e ° 4 a � a a q d 1 e 4 4 1 q 4 4 44 d a 4q .0 tl a 4qd 4 ❑ ❑ qa d d -0 aIaa ° 4 -j !_4 A 4d a A ad A 4 A d AF-24.00 'Ti Q 44 q 4 a < ad 4 a d 4 PROPOSED BUILDING 4a ICV d a a A 4 aCONNEQT EXIS7*G 9 IN, d a 444d 4 STA. 14+ p 3 L, AV 4q a d i1nRAd �7PV 237i/ a CONTR TO VERIFY —LOGATON PIPE YP, �ND 4 1 LF 6,XVC SDR 01J.76� d 4 4° S 44 ECEVA PRIOR 44 aa Aa � Ill) a a qA 4a�a TO Cops J TI4N❑-4 A'd aa a 4 1 d @ a 4 e 47 d d4 da Cog leLLCANVV a 4: d 41 S�a1+24, 131.65° L SD .4 RIM = 53.95 F1 Ad 4 a -mA a A "c(E) 248.100 a4 d 14 V d 4 1 d 4 4 d SD A S3 A d S a d 4 . A d d 4°d 4 ot A q q V /,SID 4' I e d a 1 50I� 104100 _ w 13+00 5D ----- SU -- SD:— SD — D-- SD --�-- - 5D 5© — � �5D _. _. , SD SID .— �a; Sf] -- SD SD �--- SD —�--- SD ----- 5i I TPN 2021049116 r �} E7 _ ! 1 i I 1 q, a fff G7 i :. SD—SCE--5D—SD —SO— 0 Know what's below. Call before you dig, NOTE: THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER APPROVAL DATE. THE CITY WILL NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY ENGINEER. PERMIT NO. XX--XXXXXX—XX APPROVED DATE tl a-1-1 A d) CO _= �� a 1+7 V)�4 I C W i .� LO C LO O� C as .1J �O Q v L,- 3 N v oLO � n d' N U O Q � N U z rn n O�N J W X_ cc�9 04 0 0 a W ZW IJ— J F- 10 DATE SEALED �—. JEU , P0IX'QF WA SH�Sa a � Y W 4038IST 2 <v NALREa�\ PROJECT MANAGER DE81QN G j DRAWN SA J CHE<WM car SEC T 2H R 4E FILE NO DATE 00/W/2022 SCALE r - W SHEET L3OF4 R-E NO 3W72 D APEX ENGINEERING LLC 2022 rND LEGAL DESCRIPTION (PER DEED UNDER INSTRUMENT NO. 20201230000748) FOUND MONUMENT AS NOTED LOTS 1, 2, 3, AND 4, KING COUNTY SNORT PLAT NUMBER 274023, RECORDED UNDER RECORDING NUMBER 8011050835, IN KING COUNTY, WASHINGTON; GQ� CALCULATED MONUMENT AS NOTED TOGETHER WITH THAT PORTION OF VACATED STATE HIGHWAY AND ADJOINING SAID LOTS 3 AND 4, AS RECORDED UNDER RECORDING NUMBERS 8212060518 AND (C) CALCULATED DIMENSION 8212060520, AND CORRECTED UNDER RECORDING NUMBERS 8307070635 AND (M) MEASURED DIMENSION 8307070636. (Rx) RECORD DOCUMENT (PER REFERENCE) EXCEPT THOSE PORTIONS CONVEYED TO THE CITY OF FEDERAL WAY BY INSTRUMENTS RECORDED UNDER RECORDING NUMBERS 20160108000112, TPN TAX PARCEL NUMBER 20160108000113 AND 20160108000115. BOUNDARY LINE - - - -- -- - - ADJOINER PROPERTY BOUNDARY RIGHT OF WAY LINE ROAD CENTERLINE - - - - - - - - EASEMENT LINE - -- -- SHORT PLAT LINE - - SECTION LINE AREA COVERED BY CONTAINERS O GATE POST a 0 0 6' CHAIN LINK FENCE WROUGHT IRON FENCE �X 3E- X X X X MINOR CONTOUR - --- ---- ----- -- MAJOR CONTOUR X C.0' SPOT ELEVATION 0 SANITARY SEWER MANHOLE 0 SANITARY SEWER CLEANOUT R SANITARY SEWER STUB 0 STORM MANHOLE ❑ STORM CATCH BASIN < STORM CULVERT - SD- SD- SD- BURIED STORM DRAIN LINE - - - - - - - STORM DITCH LINE --- SS - sS - ss - BURIED SANITARY SEWER LINE IE INVERT ELEVATION PVC PLASTIC PIPE DI DUCTILE IRON PIPE RCP REINFORCED CONCRETE PIPE -O- UTILITY POLE ® POWER VAULT ® POWER METER Ill JUNCTION BOX �A TRANSFORMER LIGHT POLE - LIGHT POLE WITH ARM IE ID GAS VALVE 0 CABLE VAULT SEWER MANHOLE ❑ TELEPHONE RISER RIM=242.12' CTR CHANNEL=227.2Y WATER VALVE (10' PVC-NE/SW) ® WATER METER LADDER (N) A PORTION PLANT 2 RELOCATION BOUNDARY AND TOPOGRAPHIC SURVEY SOUTH OF THE S.E. 1/4 OF SECTION 20, TOWNSHIP 21 NORTH, RANG 4 EAST, W.M., OF FEDERAL WAY, KING COUNTY, WASHINGTON 2`4 V/A TPN 1852950050 k! 6' CHAIN LINK FENCE CORNER 1.5' NORTH OF LINE N8835'45"W 335.62' BUILDING POWER EASEMENT 6 5' REC NO 20160425000549 / 3 BUILDING CORNER ON g hN PROPERTY LINE ( BUILDING TPN 2 21049163 LOT 2 + j TPN 2021049162 N �S o F 58.3 S88�VO5'E I 2.15 ry tS 1 / N88 35'45'WJi Il I �1 I r � ROW DEDICATION UNDER / BUILDING j + REC. NO. 20160108000112 LOT 3 �2s TPN 2021049155 2V POWER EASEMENT UNDER REC. NO. 8108200646 I SHED n ROW VACATION UNDER REC. NOS. 8307070635 & 8307070636 / / N 20' STORM CATCH BASIN a =a , I II 2A� / RIM=253,63' IE=251.53' (4" PVC-N)` ��• i 1 Qd IE=251.43' (4" DI-S) Q I � N88'35'45"W 230.14' o� (3® IE=25138 {4" DI-E} l Xp' j / I0 �IE=251.78 (4 PVC-W) 60' / - 6'x4.5' UTILITY EASEMENT UNDER STORM CATCH BASIN 0 246- d /1 � REC. NO. 20160108000113 � ( � RIM=252.57 1 I STORM CATCH BASIN I IE=250.32 (8" DI-W/N) a 1 i 1 RIM=253.08' A IE=250.57' (10" DI -SW) } 1 i I jf fE=251.23' (8' DI-E) / �I QQ' / O / 1 \I 5' POWER EASEMENT UNDER STORM CATCH BASIN , REC. NO. 20160425000549 I =242.16' (B' DI NW) 24 LOT 4 - _ ;.' l5 ❑ SD 5C N so SD i �❑ _ .� TPN 2Q21049043 0, SEWER MANHOLE - r 1 f I N` RIM=249.46' I sy j I J, CTR CHANNEL=22&71' j I N (8' PVC SW/SE. 6" PVC -NE) 5 244- r ! I LADDER (S) ✓ ROW DEDICATION UNDER / N r y - r SEWER MANHOLE REC. NO, 20160108000115 / I I I I RIM-254 71' z �� � ✓ Sp' SS _253 BUILDING CORNER ON PROPERTY LINE 6' CHAIN LINK FENCE CORNER EAST & 1.0' SOUTH OF LINE TPN 1852950010 oi U3 w n s z WALLED SHED I 6FT CHAIN LINK FENCE 1.5' EAST OF LINE STORM MANHOLE RIM=249.50' f IE=235.40' (36" RCP -NE) IE=234.65' (36» RCP -SW) 0 IE=239.60 (24" PVC -SE) `----LADDER------ h SD- 5D D xix K>I IRRIGATION CONTROL VALVE STORM CATCH BASIN i I I / I CTR CHANNEL=22&36' (8" PVC-SW/NE) 16 WATER EASEMENT - INGRESS, -251- sp s�s5 / i 1 / i 40' EGRESS &UTILITIES UNDER REC. NO. 6104747 5 , SEVER MANHOLE - SD TYPE 2 /� I / / EASEMENT PER SHORT PLAT - - �� ✓ sD'' �� RIMCTR CHANNEL=229.29 0 UNKNOWN UTILITY MANHOLE RIM=242.14 24 + I / / REC. NO. 8011050835 f IE=231.44' (36' RCP-E) / I 2Q 10' SANITARY SEWER 40' ROADWAY EASEMENT �� 40' SANITARY SEWER " IT UNKNOWN UTILITY VAULT IE=231.29' (36" RCP-W) \� \ EASEMENT UNDER / UNDER REC. N0. 4447709 2S3 j X-� �= / i �1 ?�1 c�$F- EASEMENT UNDER (8 PVC-SW/NE, 6 PVC -SE) OHE OHE- OVERHEAD POWER LINE IE=232.99' (8" RCP-N) � � \ REC. NO. 8802100900f 40' GAS EASEMENT �65 I REC. N0. 8601130472 LADDER (N) NO ACCESS TO 12m ALUM-5 s�Q \ _ UNDER REC. NO. 7112140376 _OHr 0HT- OVERHEAD TELEPHONE LINE LADDER (N) � �-- `� � �. -' � � _ ' -' i 1- p� � -G-G-G-G- BURIED GAS LINE v �~' ^ ~ r �- 5p 5 / STORM CULVERT RIAl=249.SEWER ANHOLE STORM MANHOLE-------,,�242`r N _-- - s� �- _G �_� - -s� / Sp Spy !� Sp ' IE=247.32 (8 DI) CTR CHANNEL=226.78' (8" PVC-NEMW) ASPHALT SURFACE OIL SEPARATION STRUCTURE---- -G �G -G G ✓ j LADDER (SE) RIM=242.20'-SD 5 -SD 55--� -� 5-5SC-SS--~--- ---- Aa I S5 s-- `�-`�'---------J � sp,.( STORM CATCH BASIN CONCRETE SURFACE IE=239.05' 32" RCP -SE) -=- �D --� a$ SS- Sg -- S5 55 sS SS - sS i 5p �1� �i r ���� TYPE 2 I TPN 2021049116 TOP DOWN PIPE=237.85 (ff ALUM-N) - �- _ �- � o r RIM=249.50' GRAVEL SURFACE WATER LEVEL=236.85' IE=246.25' (12" DI=5W) I IE=246.30' {12" Di-S} I LADDER (W) --58832'22"E 304.87' - - 4V SANITARY SEWER LADDER (N) SD SD EASEMENT UNDER I / SEWER MANHOLE 'sue T I "'° REC. NO. 8601130471 STORM MANHOLE i � sQ 5' POWER EASEMENT i ( \ STORM CULVERT RIM=249.25' RIM=241,890 so UNDER REC. NO. 7403120485 6. TALL&67' STORM .CU' (8" DI RI ACCESS, BOLT DAMAGED x CTR CHANNEL=227.09 ) I STORM CULVERT STORM CULVERT CHAIN LINK FENCE N (10, PVC-NE/SW) IE=242.34' (12" RCP) \ STORM CATCH BASIN LADDER (SE) 2§0�� IE=241.09 (8 DI) 40' SANITARY SEWER �° TYPE 2 TPN 2021049059 SEWER MANHOLE STORM CULVERT EASEMENT UNDER I \ RIM=250.37 RIM=241.30' IE=241.48' (12' RCP) REC. NO. 8509"1191 IE=244.87' (12" DI -NE) 11. STORM CATCH BASIN SEWER MANHOLE I ° IE=244.82' (12" DI-W) I CTR CHANNEL=220.35' (10' PVC-NE/SW) STORM MANHOLE RIM=251.53' STORM CATCH BASIN TYPE 2-OVERFLOW CONTROL STRUCTURE LADDER (NE) VAULT ACCESS CTR CHANNEL=22&13 (8" PVC-W/NE) TYPE 2 LADDER (S) I RIM=241.92' RIM=243.62 " TPN 2021049148 LADDER (NE) i RIM=251.4,T z / SUMP=234.07' IE=237.62 (36 CMP-E) I IE=233.18' (36' RCP -NE) I IE=239.97' (4' PVC -SE) I IE=233.13 (36" RCP-W) / STANDPIPE IE (GATE)=237.84' (8' DI -SW) I IE=233.58' (24" PVC -SE) I TOP=241.22' I LADDER (N) BTM=235.62' I I WATER LEVEL=237.67' LADDER (N) i I I I i 1� r I I I S 1/4 CORNER SECTION 20 20 PER ROS UNDER AFN 9307149002 29 NBB32'22'W 2613.72'(C) - G 20 21 1 29 IF28 21 20 r ll FOUND 1.5" BRASS DISC IN MONUMENT CASE 0.8' BELOW SURFACE ( VISITED 3-25-13 GRAPHIC SCALE 40 0 20 40 ( IN FEET ) 1 inch = 40ft. BASIS OF BEARINGS HELD NORTH 013424" ALONG THE EAST LINE OF SECTION 20 BETWEEN FOUND MONUMENTS, AS SHOWN HEREON. HORIZONTAL DATUM WASHINGTON STATE PLANE COORDINATE SYSTEM, NORTH ZONE (NAD 8312011) BASED ON RTK GPS N MEASUREMENTS CONSTRAINED TO THE WASHINGTON STATE REFERENCE NETWORK. N VERTICAL DATUM NGVD Z2 BASEDN RTK GPS MEASUREMENTS CONSTRAINED TO THE WASHINGTON STATE REFERENCE NETWORK AND TIED m I TO WSDOT BENCHMARK GP27099-140. f BM GP27099-140 ELEV=81.46 (NAVD88) ELEVATIONS CONVERTED TO CITY OF FEDERAL WAY DATUM USING USACE CORPSCON SOFTWARE VERSION 6.0.1. a BM GP27099-140 EL V=77.96 (NGVD29) m N SURVEY NOTES s 1. DATA FOR THIS SURVEY WAS GATHERED BY FIELD TRAVERSE UTILIZING ELECTRONIC DATA COLLECTION, AND z MEETS OR EXCEEDS ACCURACY REQUIREMENTS CONTAINED IN W.A.C. 332.130.090. ALL MEASURING INSTRUMENTS EMPLOYED IN THIS SURVEY HAVE BEEN MAINTAINED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 2. THIS MAP GRAPHICALLY REPRESENTS CONDITIONS AND FEATURES EXISTING AT THE TIME OF THIS SURVEY ONLY, WHICH WAS PERFORMED DURING SEPTEMBER OF 2021. 3, THE CERTIFICATION OF THIS SURVEY AND MAP IS EXCLUSIVE TO THE NAMED CLIENT WHO REQUESTED THIS SURVEY, IT WAS SPECIFICALLY DESIGNED TO MEET THEIR STATED NEED(S). THAT CERTIFICATION DOES NOT I EXTEND TO ANY OTHER PARTIES OR FOR ANY ALTERNATIVE USE OF THIS MAP WITHOUT THE EXPRESS RECERTIFICATION BY THE SURVEYOR NAMING THOSE PARTIES. 4. THE PURPOSE OF THIS SURVEY IS TO PROVIDE A TOPOGRAPHIC MAP OF THE EXISTING CONDITIONS WITHIN PARCEL NUMBERS 2021049163, 2021049162, 2021049155, & 2021049043 FOR PLANNING, DESIGN AND CONSTRUCTION. 5. UTILITIES OTHER THAN SHOWN MAY EXIST ON THE SITE. THE SURVEYOR DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. LACKING EXCAVATION, THE EXACT LOCATION OF UNDERGROUND FEATURES CANNOT BE ACCURATELY, COMPLETELY, AND RELIABLY DEPICTED. WHERE ADDITIONAL OR MORE DETAILED INFORMATION IS REQUIRED, THE CLIENT IS ADVISED THAT EXCAVATION MAY BE NECESSARY. THE SURVEYOR DOES CERTIFY THAT THEY ARE SHOWN AS ACCURATELY AS POSSIBLE FROM FIELD SURVEY INFORMATION. 6. KING COUNTY PARCEL NUMBERS 2021049163, 2021049162, 2021049155, & 2021049043 7. PARCEL AREA (TPN 2021049163): 32,979 t SQ.FT. (0.76 ACRES) j PARCEL AREA (TPN 2021049162): 307,804 t SQ.FT. (0.87 ACRES) PARCEL AREA (TPN 2021049155): 55,508 f SQ.FT. (1.27 ACRES) PARCEL AREA (TPN 2021049043): 58,221 SQ.FT. (1.34 ACRES) 8, ALL DISTANCES AND DIMENSIONS SHOWN ARE U.S. SURVEY FEET GROUND MEASUREMENTS. 9, CONTOUR INTERVALS ARE 1-FOOT AND ARE COMPUTER GENERATED FROM GROUND FIELD TOPOGRAPHY GATHERED FOR THIS SURVEY UTILIZING ELECTRONIC DATA COLLECTION. 10. THE PROPERTY AND PUBLIC RIGHT-OF-WAY LINES SHOWN HEREON ARE BASED ON RECORD DOCUMENTS 11. WE HAVE USED GRAPHIC SYMBOLS TO REPRESENT SOME FEATURES ON THIS MAP, SUCH AS UTILITIES, TREES AND FENCES. THE DEFAULT SIZE OF THOSE SYMBOLS MAY NOT REFLECT THE TRUE SIZE OF THE FEATURE ( THAT WAS MAPPED. REFERENCES 1. KING COUNTY SHORT PLAT NO. 274023 UNDER RECORDING NO. 8011050835. # SURVEYOR'S CERTIFICATE I HEREBY CERTIFY THAT THIS MAP CORRECTLY REPRESENTS A TOPOGRAPHIC SURVEY MADE BY ME OR UNDER MY DIRECTION AND TO THE BEST OF MY KNOWLEDGE REPRESENTS THE SURFACE FEATURES AS THEY IST ON THE GROUND AS OF 0913012021. TIMOTHY J. MCDANA P.L.S. NO. 45792A'l DATE NOTE: THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER APPROVAL DATE. THE CITY WILL NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ON THESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANS AS DETERMINED BY THE CITY FOUND 3' BRASS DISC ENGINEER. �VSTEDl9 MONUMENT CASE PERMIT NO. XX-XXXXXX-XX APPROVED DATE a 0 O Z C `v�o di 00 re) ov _ c y �oLJL- 3 N d� U I i uo ct U J pp ON Q iV U O � Co Lu Z x a cc 9 3 NZ 0 r Q Q Q w z ...J W H J I- U DATE SEAL® �' Z d. WA S•��9� / � T 45792 isTANC S��a PROJECT MANAOM CCU E W HAFM DEMM G1 DRAWN Uj Gj SEC 20 T 21N R 4E P� 1L NO DATE 06/0W= SCALE 'r - 417 SHEET L4OF 14 IFU NO =72 0 APEX ENGINEERING LLC 2022