21-102233-Certificate of Water Availability-06-09-2021-V1RECEIVED
Aug 21 2020
CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
Lakehaven
WATER & SEWER DISTRICT
Lakehaven Water & Sewer District — Development Engineering Section
31623 — 1st Ave S # PO Box 4249 * Federal Way, WA 98063-4249
Telephone: 253-945-1581 or 253-945-1580 * Email: DE@Lakehaven.org
This certificate is intended to provide the applicant, land use agencies &/or public health departments with
information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole
discretion, reserves the right to delay, or deny, water service based upon capacity &/or supply limitations
in Lakehaven's or Other Purveyor's system facilities.
Proposed Land Use: ® Building Permits-SFR ❑ Building Permit-MFR ❑ Building Permit -Other
❑ Subdivision ❑ Short Subdivision ❑ Binding Site Plan
❑ Rezone ❑ Boundary Line Adjustment
❑ Other (specify/describe)
Tax Parcel Number(s): 072104-9024, -9109, -9110, -9111, -9114 Site Address: 31OXX — 6th PI SW
Ex. Bldg. Area to Remain: NIA sf New Bldg. Area Proposed: 1.295+/- avg. sf ea. (16) Lakehaven GIS Grid: H-07
Applicant's Name: McCaffrey
WATER SYSTEM INFORMATION
1. ❑ Water service can be provided by service connection to an existing " diameter water main that is approximately
feet from the site.
2. ® Water service for the site will require an Improvement to Lakehaven's water distribution system of:
® a. 30+ - feet of 8" diameter water main to reach the site; and/or
® b. The construction of a water distribution system on the site; and/or
❑ c. A major portion of Lakehaven's comprehensive water system plan would need to be implemented and/or
constructed; and/or
® d. Other (describe): Lakehaven Developer Extension Agreement (active Project 6308003) required.
3. ® a. The existing water system is in conformance with Lakehaven's Comprehensive Water System Plan.
❑ b. The existing water system is not in conformance with Lakehaven's Comprehensive Water System Plan and an
Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits.
4. ® a. The subject property is within the corporate limits of Lakehaven Water & Sewer District, or has been granted
Boundary Review Board approval for extension of water service outside of Lakehaven's water service area.
❑ b. Annexation or Boundary Review Board approval will be necessary to provide service.
S. Water service is subject to:
® a. Payment of connection charges (to be determined by Lakehaven);
® b. Proof or reservation of easement(s) as required by Lakehaven;
® c. Other: Water Service Connection application required for any new/modified service connection. DE Agreement (#2
above) must be accented by Lakehaven prior to any new service connection activation(s).
Comments/special conditions: Some service pressures) greater than 80 psi indicated some Pressure Reducing Valves indicated,
contact local building official for requirements &/or additional information.
The nearest fire hydrant will be on the Property (pending completion of DE Agreement (#2 above)).
Fire Flow at no less than 20 psi available within the water distribution system is 1,000 GPM (approximate) for two (2) hours or more.
This flow figure depicts the theoretical performance of the water distribution system under high demand conditions. Fire flow rates
greater than this may be accommodated through water distribution system improvements, contact Lakehaven for additional
information.
538 Pressure Zone Est. Meter Elevation(s)-GIS: High 366+/-, Low 332+/- Est. Pressure Range at Meter(s) (psi): 65-89
I hereby certify that the above water system information is true. This certification shall be valid for one (1) year from the date of
signature.
Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR
Signature:
/LL A-- __
Date:
!-7r
v
Mirror Lake Highland wtr.docx (Form Update 1/3/17) Page 1 of 2
5557700030 771620002 �71�t320D1IU, 721049235
3' 0813
LU
0721049106
•-' i71$20003 771820010
5557700040 30527 3082$
3M 30826 0721049115
� � i
r+ 1$200040 g.
t;
0721D4911$
MEW55577000501620009
38034 30834
0721049189
5557700080
30842 71t�2000 1820008
30147z&j 3084$
072/049114
5557700070
3,pg5p 7 182000M
30853 71$2000
a NOR
30852
5557700080
30858
0721
0721049183 0721049/53
555770fl090 3101 3100$
31000ir
� 0721049110
'55577p
04
0721049028 0721049151 IHIGHLAND
31D10 31fl07 ...r 310D8 G303003pjQp 9U5557700110
31020 0721040 KE
ff
0721D49149 0721049111
31009 31010
55,57700120
31030
5�577001PA 072104 `072
31040 3102
Ex.
Hydrant A7
0721049239
31037
D721049027
0721049199
708
IDTE: Lakehaven Water and 5ewe�
District neither ssarrants nor guarantees
the accuracy of any facility information
wovided. Facility loa3tions and conditions
are subject tofieldverdication.
1049144
$1$
0721049024
$04
H
0721048003
414
Ex. WtrSvc 3BB1
5/ 8"x3 j4" Meter
w �
10 0721049074 072104900 3
1$05 414 i
Water Certificate of Availability
Parcels 072104-9024, 9109,-9110A111, -9114
0 107 a00
10! 19/2017
Mirror Lake Highland wtr.docx (Form Update 1/3/17) Page 2 of 2