Loading...
04-102380 r:CEIV CIT.OF G CONSTRUC I iON PERMIT APPLICATION 'uv F7Y � JUN 2004 APPLICATION NUMBER: CI -' 923$D- O APPLICATION NUMBER: - - CITY OF FEGERfAL 1N BUILDING DEPT, AY APPLICATION NUMBER: **The following is required information—Please print(in ink)or type** Please note: Electrical,Fire Prevention Systems and Engineering permits may require a separate application. ■ PROPERTY INFORMATION SITE ADDRESS: 31455 28th Ave S TAX ASSESSOR'S TAX/PARCEL# 0921049054 LEGAL DESCRIPTION OF SUBJECT PROPERTY(ATTACH SEPARATE DESCRIPTION IF LENGTHY): 092104 54 LOT 1 TGW POR OF VAC RD ADJ OF KCSP #484069 REC #8409100751 SD SP ■ PROJECT INFORMATION TYPE OF PROJECT(This application): c BUILDING ❑ PLUMBING o MECHANICAL ❑ DEMOLITION o ELECTRICAL D ENGINEERING X FIRE PREVENTION SYSTEM PROJECT DESCRIPTION (Provide detailed description): Install new NFPA 13 Wet fire sprinkler system overhead PROJECT NAME: Federal Way Head Start ■ PEOPLE INFORMATION PROPERTY OWNER: NAME: DAYTIME PHONE: Federal Way Public Schools MAILING ADDRESS(STREET ADDRESS;CITY,STATE,ZIP): CONTRACTOR: NAME: DAYTIME PHONE: Olsen Fire Protection 253-856-1515 MAILING ADDRESS(STREET ADDRESS;CITY,STATE,ZIP): EVENING PHONE: 4710 B Street NW,Suite 105,Auburn WA 98001 CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER: FAX NUMBER: 19-99-107640-00 BL 253-856-7075 CONTRACTOR'S REGISTRATION NUMBER: EXPIRATION DATE: (copy of card required) OLSENFP012CH 9/30/2004 APPLICANT: NAME: DAYTIME PHONE: Kyle Barrow SAME AS ABOVE MAILING ADDRESS(STREET ADDRESS;CITY,STATE,ZIP): EVENING PHONE: SAME AS ABOVE RELATIONSHIP TO PROJECT: FAX NUMBER: ARCHITECT o TENANT Ci OTHER( DESCRIBE):SPRINKLER CONTRACTOR SAME AS ABOVE E-MAIL ADDRESS: CONTACT PERSON FOR THIS PROJECT: o PROPERTY OWNER o APPLICANT ❑ CONTRACTOR DETAILED BUILDING INFORMATION EXISTING USE: EXISTING BUILDING ASSESSED/APPRAISED VALUATION PROPOSED USE: PROPOSED VALUATION FOR IMPROVEMENTS $ r 1 / 66 V SPRINKLERED BUILDING? o YES o NO FIRE SUPPRESSION SYSTEM PROPOSED • IRED: o ■ NO WATER SERVICE PROVIDER: o LAKEHAVEN o HIGHLINE ❑ TACOMA ❑ PRIVATE(WELL) SEWER SERVICE PROVIDER: ❑ LAKEHAVEN ❑ HIGHLINE ❑ PRIVATE(SEPTIC) , **NEW RESIDENTIAL CONSTRUCTION ONLY** NUMBER OF BEDROOMS: ESTIMATED SELLING PRICE: $ ■ PROJECT,FLOOR AREAS FLOOR EXISTING SQ.FT. PROPOSED SQ. FT. TOTAL BASEMENT FIRST SECOND THIRD FOURTH OTHER FLOORS(DESCRIBE) DECK GARAGE HOW MANY FLOORS? TOTAL: • FIXTURES Indicate number of each type of fixture MECHANICAL AIR HANDLING UNIT(S) EVAPORATIVE COOLER(S) GAS LOG(S) REFRIG.SYSTEM(S) BBQ(S) FAN(S) HOOD(S) WOODSTOVE(S) BOILER(S) FIREPLACE INSERT(S) RANGE(S) MISC.( ) COMPRESSOR(S) FURNACE(S) DUCT(S) GAS PIPE OUTLET(S) HEAT SOURCE: o ELECTRIC ❑ GAS PLUMBING BATHTUB(S) LAVATORY(S) URINAL(S) WATER HEATER(S) DISHWASHER(S) RAIN WATER SYS. VACUUM BREAKER(S) o ELECTRIC ❑ GAS DRINKING FOUNTAIN(S) SHOWER(S) WASH MACHINE OUTLET GAS PIPE OUTLET(S) SINK(S) WATER CLOSET(S) MISC. ( ) INTERCEPTOR(S) SUMP(S) ■ DISCLAIMER/SIGNATURE BLOCK I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and further,that I am authorized by the owner of the above premises to perform the work for which the permit application is made. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses,and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the City of Federal Way, but only where such claim arises out of the reliance of the city,including its officers and employees,upon the accuracy of the information supplied to the city as a part of this application. NAME/TITLE: 'lll 4 6,,- DATE: i��r'�— o PROPERTY OWNER APPLICANT ❑ CONTRACTOR FOR OFFICE USE ONLY: o NEW ❑ ADDITION ❑ ALTERATION ❑ REPAIR ❑ TENANT IMPROVEMENT CENSUS CODE: LOT SIZE: ZONING DESIGNATION : BUILDING SHELL ONLY? ❑ YES ❑ NO COMP PLAN DESIGNATION BASIC PLAN? ❑ YES ❑ NO SECTION TOWNSHIP RANGE I NEW ADDRESS REQUIRED? E YES ❑ NO PLATTED LOT? ❑ YES ❑ NO CHANGE OF USE? ❑ YES ❑ NO COMMUNITY DEVELOPMENT SERVICES•33530 FIRST WAY SOUTH•PO BOX 9718•FEDERAL WAY,WA 98063-9718•253-661-4000•FAX: 253-661-4129 wvw.cityoffederalwr y.com Construction Permit Fee Calculation Street *******PLEASE NOTE: ALL FEES MUST BE VERIFIED BY CITY STAFF PRIOR TO ACCEPTANCE OF PAYMENT. CHECKS FOR INCORRECT AMOUNTS WILL NOT BE ACCEPTED!******* Building, mechanical, and fire prevention system fees are based on the following schedule. TABLE A TOTAL VALUATION FEE FACTOR (1)$1.00 to$500.00 (1)$26.00 (2)$501.00 to$2,000.00 (2)$26.00 for the first$500.00 plus$3.50 for each additional$100.00 or fraction thereof,to and including $2,000.00 (3)$2,001.00 to$25,000.00 (3)$78.50 for the first$2,000.00 plus$15.50 for each additional$1,000,00 or fraction thereof,to and including$25,000.00 (4)$25,001.00 to$50,000.00 (4)$435.00 for the first$25,000.00 plus$11.00 for each additionaL$1 000.00or fraction thereof,to and including$50,000.00. (5)$50,001.00 to$100,000.00 (5)$710.00 for the first$50,000.00 plus$8.00fo each additioaal$1,000.00 or fraction thereof,to and including$100,000.00. (6)$100,001.00 to$500,000.00 (6)$1,110.00 for the first$100,000.00 plus IEQQfor each additional$1,000.0 or fraction thereof,to and including$500,000.00 (7)$500,001.00 to$1,000,000.00 (7)$3,510.00 for the fist$500,000.00 plus$5.50it:each additional$1,000.00 or fraction thereof,to and including$1,000,000.00. (8)$1,000,001.00 and up (8)$6,260.00 for the first$1,000,000.00 plus$Q000_for each add_hcwlaf$L00010 or fraction thereof. Bold number is the base fee for the specified increment Italicized,underlined number is the fee per additional specified increment PLUS: Add 65 percent of the base building permit fee for plan review fee. Add 25 percent of the base mechanical permit fee for mechanical plan review fee. Add 15 percent of the base building permit fee for Fire District#39 surcharge,commercial only. Add$4.50 for WA State Building Code Council, plus$2.00 per unit for duplex&above. **Electrical,plumbing,and mechanical fees are calculated separately** il3 E. BUILDING PROPOSED VALUATION: FEE FACTOR FROM TABLE A: Number: (a) Base Fee: (b)Additional Increment Fee: Estimated Permit Fee: (1) Estimated Plan Review Fee: (2) Estimated FW Fire Department Surcharge: (3) (COMMERCIAL ONLY) ■ MECHANICAL PROPOSED VALUATION: FEE FACTOR FROM TABLE A: Number: (a)Base Fee: (b)Additional Increment Fee: Estimated Permit Fee: (4) Estimated Plan Review Fee: (5) ■ FIRE PREVENTION SYSTEM PROPOSED VALUATION: $ 19,600 FEE FACTOR FROM TABLE A: Number: _ (a) Base Fee: (b)Additional Increment Fee: Estimated Permit Fee: (6) $357.50 Estimated Plan Review Fee: (7) $232.38 ■ PLUMBING Base Fee Number of Fixtures $22.50 +{ X$8.00/fixture} = (8) Estimated Permit Fee Estimated Permit Fee X .65 = (9) Estimated Plan Review Fee Miscellaneous Fixture Charge: (10) Sub Total (Page One): Line(s) (1)+(2)+(3)+(4)+(5)+(6)+(7)+(8)+(9)+(10) = (11)