04-100563City of Federal Way Community llevelopment Services Building - Single Family Permit #: 04 - 100563 - 00 - SF
P.O. Box 9718
Federal Way, WA 98063-9718
Ph: (253) 835-7000 Fax: (253) 835-2609 Inspection request line: (253) 835-3050
:i
Project Name: SONG
Project Address: 29408 2ND AVE SW Parcel Number: 119600 3420
Project Description: NEW - Construction of new 3082 sqft residence with 1058 sqft unfinished basement, 782 sqft attached,
basement garage, 569 sqft deck, including plumbing & mechanical. ***5 Bedrooms, Est. selling price:
$280,000***
Owner
Applicant
Contractor
Lender
Dayleena Song
SUN MOON DESIGN *ivlINH NGUY
Dayleena Song
Dayleena Song
32104 8TH AVE S
14404 31 ST ST SW FLOOR K-308
32104 8TH AVE S
FEDERAL WAY WA 98003
BELLEVUE WA 98007
32104 8TH AVE S
FEDERAL WAY WA 98003
FEDERAL WAY WA 98003
Includes:
Census category: 101 -New si
#1
#2 1
#3
#4 _
Occupancy Group:
R-3
U-1
Construction Type:
Type V - N
T pe V - N
_
occupancy.y Load;
Floor Area (Sq, Ft.): ------ - -- -
J— —
1st Floor Proposed Sq. Feet .. ........................... i.... 166E
Basement Proposed Sq. Feet................................101 1
2nd Floor Proposed Sq. Feet................................1416
Basic Plan....................................:.......I.... No
Census Category_... ................. ......... 101 -New single family house
Construction Type#2.................. :,,.............. ::. »..
Type V - N
Deck Proposed Sq. Feet ...... ................................
569
Garage Proposed Sq. Feet_ .............................. ...660
Height of Structure .............
:....... 32.5
Mechanical .............................
Yes
Occupancy Group # 1...........................................
R-3
Occupancy Group#2....... ....................................
U-1
Other Proposed Sq. Feet ......................................
47
Plumbing.............:...................................
Yes
Total Building Sq. Feet... ..........................
..5491
Total Proposed Sq. Feet ........................................
3129
Zoning Designation .............................................
RS 9.6
Plumbing Fixtures
Description Quantity. Description Quanttty _ _ Description Quantityl
�SaWtubs 3 Dishwashers 1 Laundry Washer Outlets 1
r Lavalode:s 3 j Other Plumbing Fixtures Z Showers
Sinks �- 2 Water Closets 3 Water Heaters
Mechanical Fixtures
i Description Quantity' Descri I Quant1, i Descri tion Quan!
Ducts 1 1 Fans 5 Fireplace inserts 1
Furnaces -- 1 } { Gas Logs 1 Canges
CONDITIONS:
1) Any damage, caused by construction traffic for this project, to the private access road (SW 294th St) must be repaired,
inspected, and approved by Public Works, prior to occupancy.
2) Prior to any clearing or grading on a lot; the owner/builder shall install temporary erosion/sedimentation control
facilities approved by the City. These facilities must ensure that dirt or sediment laden water does not enter the public
drainage system, adjacent lots or public streets. The owner/builder bears the responsibility to maintain the facilities in
proper working order, replacing as necessary. The facilities may be removed only after such time as construction is
complete & landscaping is installed. See attached for standards and site plan for location of silt fencing.
3) Rockeries over 4-feet in height require seperate building permits.
4) See Feb 10, 2005 Approved site plan for Public Works approved drainage plan.
5) This decision shall not waive compliance with future City of Federal Way codes, policies, or standards relating to the
su b j �'ct;,pToposJ►..
PERMIT EXPIRE _i August 15, 2005.
Permit issued on February 16, 2005
I hereby certify that the above information is correct and that the construction on the above described property and
the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and
the City of Federal Way.
Owner or agent: as Date:
City of Federal Way
Certificate of Occupancy
This Certificate issued pursuant to the requirements of Section 110.3 of the Uniform Building Code certifying that at
the time of issuance, this structure was in compliance with the various ordinances of the City regulating building
construction or use. This certificate is valid ONLY when endorsed by City staff.
Tenant Name: SONG
Address: 29408 2ND SW
Permit number: 04 - 100563 - 00
#1 #2 43 #4
Occupancy Group: R-3 U-1
Construction Type: Type V - N Type V - N
Occupancy Load:
Floor Area (Sq. Ft.): _ _
Owner Dayleena Song
Name: 32104 8TH AVE S
Address: FEDERAL WAY WA 98003
!12P4, Mce-: , C6C)
Building Official
ro- -�/-6)& Gc,J
Date
The priorily focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely
affect the health and safety ofthe general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time
and personnel limitations), the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance
with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use ofsaid structure or the land upon which it is
situated. Such compliance is the responsibility of the owner and/or occupant of the premises,
THIS CARD IS TO r7-. MIN ON -SITE'
cirr oI- r Community Development Inspection Record
Federal Way IVR INSPECTION REQUEST PHONE # (253) 835-3050
PERMIT #: 04-100563-00-SF
Owner: DAYLEENA SONG
Address: 29408 2ND AVE SW
FEDERAL WAY, WA 98023
This card is part of your required inspection documents. Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD.
Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not
be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections
are logged on the back of this card.
❑ Temp. Erosion Control (4365) ❑ Footings/Setback (4110) ❑ Foundation Wall (4115)
To be done prior to breaking ground Approved to place concrete Approved to place concrete
1 i
By Date By `�� Date 5 By r Date`
❑ Drainage/Downspout (4040)
Approved to backfill
By ci Date Q/ -I r, ej
❑ Undertloor Framing (4235)
Approved to sheath floor
By Date
❑ Roof Sheathing (4220)
Approved to install roofing T
By f l Date
❑ Gas Piping (4125) /_4
Approved to release test
ByfY Date
❑ Framing (4120) l
Approved to insulate
By ,6w- GJ Datg/4 -
❑ Final - SWM (4375)
Approved
By < ,e Date''.Z '�. O
❑ Final - Building (4050)
Approved
By < ci Date �.
❑ Plumbing Groundwork (4190)
Approved to cover
By��� Date
❑ Floor Sheathing (4105)
Approved to install flooring
By22�_ Date(i� ~J
❑ Rough Plumbing (4230)
Approved
By ""( Date % r
Fire/Draft Stops (4095)
Approved
l
ByQ, ".) Da tq, 2 - 4?A
❑ Insulation (4150)
� ^^ Approved to install wallboard
! �.
By — tj Date /
Final - Mechanical (4065)
Approved
By �) % Date %Z-1 I�)
Temp. Erosion Maintenance (43
Approved
By Date
❑ Slab/Concrete Floor (4255)
Approved to place concrete
p�r
By PZ4L— Date `/IIl1
❑ Shear Walls (4245)
Approved to install siding
By L< « � DatV2 Yz
❑ Mechanical Rough -in (4165)
Approved
By Date ��..
NOTE: Prior to scheduling a Framing (4120)
inspection; Electrical, Plumbing & Mechanical
Rough -in and Fire/Draft Stop inspections must be
igned-off and approved. IBC 109.3.4/UBC 108.5.-
Gypsum Wallboard Nailing (4130)
Approved to install mud & tape
Date g-2,(9.0
❑ Final - Plumbing (4075)
Approved
By G Date 9 �.
MAY 19'r.2005 ' 17 :15 2538626291 Page 2
GEORGE GIERGL% T. E.
CJVU,STXucTURAL-G0TEQHMCAI-
12701 111ih Aire B
PuyaUup, Wa 98374
(253) 8W3399
May 19, 2005
Ms. Kim Song
Federal Way, Wa
Re: Single family re:sidcnce located olTSW 294th tit, Federal, Way, Wa,
Parcel to 1 19600-3420, Federal Way, I)erinitltO4-100563-000-00-SF; Song,
Dear Ms. Song:
An inspection letter dated May 14, 2005, was written by our office in regard of the soils
bearing inspection, Under The ]findings section, it was stated that the visit was made on
April 13, 2004, 'Phis was a mistake, and the visit to the site was made on Saturday May
14, 2005- And as stated, the forms were already in place.
We apologize for any inconvenience and hope this letter corrected the mistake,
Should you have any questions regarding the content of this letter or the inspection
report, please Comet George Gergis at the above address.
Sincerely,
i iZUr�" ,c: 'is
MAY 19',,2005A7:15 2538626291 Page 3
GEGRGE GERGK P. E.
CIVUATRUCTURAL-CWOTEG'MCA1-
12701 111th Ave B
Payallup, Wa 98334
(253) M3398
May 14, 2005
Ms. Kim Sony,
l�ederal Way, Wa
Tte: Single family residence located off SW 294th tit., federal Way, W.I.
Parcel 9 119000-3420, Federal Way_ I)crtiiit�t04-100563-000-00-SI-; Song,
Dear Ms. Song:
At your request, t.hi letter is to address the soils bearing issue ,a.t the subject building.
PURPOSE OF LET I UR
As stated, the purpose of this letter is to address the lullowing,
1- Soils Rearing in the JbUndatio❑'area at the Subject project.
FINDINGS
On April 13, 2004, at your request, the writer visited the Subject site and performed [lie
needed investigation to address the soils condition and bearing capacity at the building
location (car the subject project. As per our inspection, [lie following was observed-
1 - The ground was excavated and the most ol'the farms were placed in preparation for
the concrete placement, At the time of the inspection, the ground was wet due to
continuous rain 1br some long period at that day. Some minor standing water was
seen in sotrte area.
2- It appears that most of the preparation was made except For some small areas where
some soils from the excavation were inside the lbrrn area possibly due to movement
fro» n the soils adjacent: to the Bums.
TESTING
Probing was performed to provide a soils bearing itil'orrnation. Probing was made
utilizing a 3/8" bar.
MAY 19',,2005 ,17:15 2538626291 Page 4
Kim Song Soils
Page 2 of 2
CONCLUSION AND RECOMMENDATIONS
Based on the a.hove inspection we may conclude, the lbllowing;
A) The Soils bearing, teaches the assurned 2000psf design bearing.
11) Aiiy loose soils must be removed prior to the concrete installation.
(') Scattered standing water may be allowed if under or about 1/1 6"inch and only in few
areas, otherwise to be removed prior to concrete installation.
LIMITATIONS
This inspection and conclusions are only limited the above mentioned issue only. We
make no warranty either expressed or implied to the future integrity of the structure or the
site. Inspection was niade to the best ol'our ability and based on generally acceptable
engineering and inspection methods for a similar situation. Comply with all requircrncrits
of C;co report is necessary.
Should you have any questiow, regarding the content ol'this report, please contact ("ieorge
(iergis at the above address,
Sincerely,
Cleot'L (ic is
rcPi►�za: b , - �.M
CONSTRUCTION P RR
CITY OF �. - FFLU 19 Z004 APPLICATION NUMBER:
Federal Way APPLICATION NUMBER:
�,I�"Y OF F�.f}EFiAI. WAY
r�11II n�niCz DE 7. APPLICATION NUMBER:
**The following is required information —Please print (in ink) or type'L
APPLICATION
i�
". _ �o S1
Please note: Electrical, Fire Prevention Systems and Engineering permits may require a se-VnWe ap C
tttrn.
PROPERTY CFO •
SITE ADDRESS: �Db�'� �=�'"" ASSESSOR'S TAX/PARCEL #: 1196003420
LEGAL DESCRIPTION OF SUBJECT PROPERTY (ATTACH SEPARATE DESCRIPTION IF LENGTHY): lots 11 12 and 13.L Block
31 Buenna according to the Rlat thereof recorded in volume 6 of plats, page 29 in KinqC9_u_n_tY..
Wash in tan. To ether with that onion of the South half of vacated Third Street I in between the East
line of said tat 11 and the West line of said lot 13 in block 31 roduced northerl to ether with an
easement for roadwa over the North 20 feet of the South half of vacated Third Street I in between the
East line of lot 8 block 31 of said plat and the West line of lot 16 block 31 of said lot roduced
northerl exce t that ortion lying within the above described main tract.
TYPE OF PROJECT (This application): BLIILDING LUMBING X MECHANICAL DEMOLITION
ELECTRICAL >L�JPNGINEERING Ci�FIRE PREVENTION SYSTEM
PROJECT DESCRIPTION (Provide detailed description): Sin le familyresidence,�* `C,n�}ew construction
/.' ir, i r. r F i ► n G 1 111 1 i t' I' 1-C ! I f/i�i. *' � V"41 aA '
PROJECT NAME: Kim Song's Residence
PROPERTY OWNER: NAME:
Dayleena K. Song
MAILING ADDRESS (STREET ADDRESS; CITY, STATE, ZIP):
32104 8tti Avenue South
CONTRACTOR: NAME:
Out to bid n
MALLING ADDRESS (STR ODRESS; CrTY, A �,ZTPI)�
):
CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER:
NUMBER:
(copy of card required)
APPLICANT: NAME:
Minh Nguyen, Architect
MAILING ADDRESS (STREET ADDRESS; CITY, STATE, ZIP).'
14404 NE 31' Street, #K-308MffA9� 7
RELATION5HIP TO PROJECT:
ARCHITECT ❑ TENANT ❑ OTHER( DESCRIBE):
CONTACT PERSON FOR THIS PROJECT: ❑ PROPERTY OWNER APPLICANT ❑ CONTRACTOR
DAYTIME PHONE:
(253) 476-7225
DAYTIME PHONE:
EVENING PHONE:
( )
FAX NUMBER:
( )
EXPIRATION DATE:
DAYTV.1k PHONE:
(425) 861-0759
EVENING PHONE:
(425) 861-0759
FAX NUMBER:
(425) 869-2404
EMAIL ADDRESS:
DEARMINH@hotmail.com
EXISTING USE: N/A EXISTING BUILDING ASSESSED/APPRAISED VALUATION $ NIA
PROPOSED USE: PROPOSED VALUATION FOR IMPROVEMENTS: $
SPRINKLERED BUILDING? ❑ YES XNO FIRE SUPPRESSION SYSTEM PROPOSED/REQUIRED: ❑ YES ❑ NO
WATER SERVICE PROVIDER: XLAKEHAVEN ❑ HIGHLINE ❑ TACOMA ❑ PRIVATE (WELL)
SEWER SERVICE PROVIDER: XLAKEHAVEN ❑ HIGHLINE ❑ PRIVATE (SEPTIC)
**NEW RESIDENTIAL CONSTRUCTION ONLY**
NUMBER OF BEDROOMS: S ESTIMATED SELLING PRICE: $ ,
FLOOR
exis I LNU b%
None
BASEMENT
FIRST
None
SECOND
None
THIRD
None
FOURTH
None
OTHER FLOORS (DESCRIBE)
N/A
DECK
None
GARAGE _
None
HOW MANY FLOORS? 1
0
TOTAL:
_
47
1666
1416
N/A
N/A
N/A
569
Indicate number of each type of fixture
MECHANICAL
TOTAL
1666
1416
N/A
N/A
N/A
569
T `(includes unfinished
basement
ej
AIR HANDLING UNIT(S)
EVAPORATIVE COOLER(S) 1 GAS LOG(S)
�.'"000(&').
1 REFRIG. SYSTEM(S)
WOODSTOVE(S)
BBQ(S)
BOILERS)
D*
1 FIREPLACE INSERT(S) 1 RANGE(S) F
MISC. )
COMPRESSOR(S)
DUCT(S)
1 FURNACE(S)
1 GAS PIPE OUTLET(S) HEAT SOURCE:
❑ ELECTRIC ❑ GAS
PLUMBING
I
3 LAVATORY(5)jjj URINAL(S)
1 WATER H ATER(S)
3 BATHTUB(S)
1 DISHWASHER(5)1
RAIN WATEq SYS. VACUUM BREAKER(S)
❑ ELECTRIC GAS
DRINKING FOUNTAIN(S)
1 -- SHOWER S) i 1 WASH MACHINE OUTLET
A
�
1 GAS PIPE OUTLET(S)
2 SINK(S) 3 jATER CLOSET(S)
`�
MISC. )
INTERCEPTOR(S)
SUMP(S)
I certify under penalty
further, that I am authorized
further agree to hold har 1
investigation and defen f u
Federal Way, but only er
of the information su pjie t �
NAME/TITLE:
❑ PROPERTY
iirt
t the information furnished by me is true and correct to the best of my knowledge, and
the above premises to perform the work for which the permit application is made. I
eral Way as to any claim (including costs, expenses, and attorneys' fees incurred in the
h may be made by any person, including the undersigned, and filed against the City of
out of the reliance of the city, including its officers and employees, upon the accuracy
of this application.
DATE:
❑ CONTRACTOR
12" RGP
190
-- ` v
r,
r, It
r,
r,
AspNLr1
tr
Y.-
RI P1 ROADUTAY @.
EA5EMENT��
'"1003041600i3S3
O
{ NC
RE55 AND '.N r
! EGRESS EASEM_X_ REO iREC�
REG. "0373357 d 5EE DTI, i.,
/,may.✓ �..,-- -L t"\
4" FLEXIBLE
I PERFORATED
1 FIFE
-
s
0
EX{5-' NG
�_OUSE —
2
V_G-ET'ATED
AREA BUFFER
ALONG THIS
PATH O
0
v
I.9'
IT
RIM=204.1
I^PROVIDE 10'Wx25'L GR'i;SHED ROCK1 .NV=i90./o E
TEMP DRIVEWAY, PRIOR TO ;NV=1',Z&,4 N.
CONSTRUCTION, PER FEDERAL WAY
CITY'S STANDARDS. 5EE /A2.2 0
O
I
2,WX2,4 DRAIN TRENCH —7
FILLE WITH 1-3/4"
x CU51-IEP ROCK
T04
r
NG.
CULVERT_
+
k
—4"TO 6'm
J
; ROCK PAD!
:00'Xic')
'
'
N
w
204
�
I
2" 51-4EET FLOW
D15
ERSION,
10' MIN I
Ld
L014G DRIVEWAY
TED
V)
+
.
2 SLOPE
2%
SLOPE/
AREA BUFFER/
'
ALONG TF415 /
'.0
®
/
2
J
a C r A
0 '
!- PVC Plf'F'.
ALT s
f i 4 (1820'Sf)
' YARD IN 11
CAtcr iASIN (, `
pz
/10
s20 13'-3' i r
13'-3' --�=---�--�--�-�J i
-TYP 5 2.i9(TOP OF FTDW, .' "SANITA. "Y�
sEu�Ei
21
+ROOF +
'DRAIN
,-OUNC)4T!0N 0
{ �� fit cf �l,lzLL Qe
+ i 2M (TOP OF FTDN)
'(� j 210 (T.Orv-:)
4.0 DS ; 21S TOP OF FTDN)
Tt.p -
rlbV
—:
!� RGOF L iNE � Q i
I
I
i
N89 0322 "W; 75. 00 ,
/
IV
0
owl-IT-13
56MT..
A
3'-0'
`94TH ST. _
/I (VACATED THIRD STREET)
I
I-- i
I wi
RGAv^u AY EASc^"E\'
r RAC. a2003041600353
i
I
I
'
I
I
ti�
/
I
i'
i
I
BUILDING HEIGHT CALCULATIONTEDERAL WAY CTTY
PLEASE NOTE THE AVERAGE SdILDINCs ELEVATION IS DETERMINED BY
TAKING THE ELEVATION AT MID POINT ALONG EACH OF THE FOUR SIDES
OF THE SMALLEST SQUARE THAT ENCLOSES THE BUILDING AND THEN
THE AVERAGING THE ELEVATIONS TAKEN AT THE MID POINT.
MIDPOINT OF SIDE sl: a 210.00
MIDPOINT OF SIDE +'2: a 21800
M0PONT OF SIDE 3: a 21SAW
MIDPOINT OF SIDE 04: a 20600
AVERAGE BUILDING ELEVATION (A B E) — 213.00
SITE INFO
662FT
FERGENTAG-E
LOT AREA (75'xi30')
9-50
5UIDiNG FOOTPRINT
1o50
die BLDG COVERAGE
ASPIHALT DRIVEUJAY
GONG. STAIR «DECKS «
ROOVES
4100
42% !MPERVIOU5 SURFACE
sl ,
�f f
a"�
FL XIBLE
P�RFciRATEES / /
PIPE If P.
1
SITE PLAT
SCAT 0 -0
0 510, 20, 30, 40'
PROVIDE SWALE -
GRADE t0 DRAIN
TO APPROVED
414 701NsPL4.: nTP.
DRAM / CATCH BMW
�— 4'
- 4' M9WM4TEp ?I,G
PIPE FOOTING
DRANAW (PIPE SLM
PER PLAN)
I'-3/4° GRAVEL
WATER'AKE 64ALL ME 9ELOW
FROM 60TT0Pf OF P-04ELL SEE
SM TEST REPORT FOR WATER
4x4 P.T. POST • S'-g
OL. (NOT sworn ON
i PLAN FOR DWG'S
CLARIFICATION)
f
PROVIDE SWALE -
GRADE TO DRAIN
TO APPROVED
SYSTEM
i -
2x& P.T, W/ 12)
I/4x4t,1" UD
SCREW
AQ IAr
SACOILL WITH 4 TO 6 INCH
GMARRY SPALLS
r — FILTER FAEIC WRAP ALL
AROUND
�— 4' 0 PERFORATED RIGID PIPE.
SLOPE TO ORAN AND CONNECT TO
STORM DRAIN SYSTEM. PROVIDE
CLEAN OUT • STRATEGIC POINTS
�-11/2"-3/4" GRAVELAUASH ROCK
TYP. ROCKERY RETAINING WALL DTI
SCALE: 1"=1'-0"
TYPICAL FLO-WELL DRAINAGE DETAIL
SCALE: 1"= V-a'
f�J
-�
OOLVCLEAN=NC s+AW62wAce DRAIN
OI11.ET NDs' RUSD69
/--'7) FL04W6L N08F94814 WRAP ALL
/ .affirm W/ FILTER MaRC
/— BACMLL W/ SAND
NI CF FIL
� CO
CONWCT TO
POO"
PL.OdtELL 1
3
Iles 8F
YES
PLO-YEL7.4
2
U18F
YES
RA-uELL 9
t
It00 SF
YES
SEE $ITE PLAN N' It
av»rze n a..
SUBMITTED !
JUN 2 2 2004 i h.
14404 N.E. 31st St., W-30:
Bellevue, WA 98007
Tel: 425-861-0759
Fax: 425-869-2404
DEARAM*4H@hotmail.com
I
I
Ij
u
I
co
i III
z111iQ
j
I
/Date: 2EClst.2003 \
Project: A0603
Name: MIN
Scale: AS SHOWN
3- 8 04 PER CITY
A
2.1