21-103984-Floor Plan-09-23-2021-V1ABUCAfZ.... RESIDENCE GARAGE CONVERSION PROJECT TEAM OWNER XXX 3809 S 337TH STREET FEDERAL WAY, WA 98001 T: (206) 504-6629 ARCHITECT GRAVES + ASSOCIATES, PLLC CONTACT: BEN CHILDS 3110 RUSTON WAY SUITE E TACOMA, WA 98402 T: (253) 279-0444; eMAIL : bchilds@gravesassoc.com PROJECT SCOPE INTERIOR REMODEL AND CONVERSION OF AN EXISTING 441 SQUARE FOOT ATTACHED GARAGE INTO HABITABLE LIVING SPACE IN A 2-STORY, SINGLE FAMILY RESIDENCE. A SMALL BATHROOM IS PROPOSED IN AN EXISTING LAUNDRY ROOM. NO OTHER WORK IS BEING PROPOSED TO THE EXISTING HOUSE. THE PROJECT WILL NOT EXPAND BUILDING SQUARE FOOTAGE, ONLY BUILDING CONDITIONED SQUARE FOOTAGE. GENERAL NOTES 1. THE CONTRACTOR IS RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH THE CONTENT OF THESE DRAWINGS PRIOR TO PROCEEDING WITH THE WORK. 2. IN THE EVENT THE CONTRACTOR FINDS A CONFLICT OR DISCREPANCY WITH THESE DRAWINGS, THE ARCHITECT SHALL BE NOTIFIED IMEDIATELY IN WRITING. SHOULD THE CONTRACTOR PROCEED WITHOUT NOTIFYING THE ARCHITECT OF SUCH CONFLICT, THE CONTRACTOR SHALL BE PROCEEDING AT HIS OWN RISK OF ASSOCIATED LIABILITY. 3. THESE DRAWINGS SERVE TO REPRESENT DESIGN INTENT AS DIRECTED BY THE OWNER & COMPLIANT WITH GOVERNING JURISDICTIONAL LAW. IN NO WAY SHALL THESE DRAWINGS SERVE TO DICTATE METHODS OF CONSTRUCTION RELATIVE TO ADHERENCE TO EITHER. IT IS THE CONTRACTOR'S & OWNER'S RESPONSIBILITY TO WORK WITHIN THE PARAMETERS OF THE AGENCY APPROVED DOCUMENTS TO MAINTAIN THE INTEGRITY OF THE DESIGN INTENT AND AGENCY COMPLIANCE. 4. THESE DRAWINGS ARE BASED ON A SURVEY AND LIMITED FIELD MEASURING. THE CONTRACTOR SHALL DOCUMENT AND VERIFY THE FOUNDATION IN RELATION TO THE PROPERTY BEFORE PROCEEDING WITH ANY WORK. ABBREVIATIONS: ABC AGGREGATE BASE COURSE MIN. MINIMUM ADJ. ADJUSTABLE N.T.S. NOT TO SCALE BD BOARD N.W. NEW WORK BOT. BOTTOM O.C. ON CENTER CLG. CEILING O.T.S. OPEN TO STRUCTURE CENTERLINE P.T. PAINT PWD PLYWOOD CLR. CLEAR P.T. PRESSURE TREATED CLO. CLOSET R RANGE COL. COLUMN REF. REFRIGERATOR COMP. COMPOSITION REINF. REINFORCED CONC. CONCRETE SIM. SIMILAR CONT. CONTINUOUS SQ. FT. SQUARE FEET C.J. CONTROL JOINT STL. STEEL DTL. DETAIL STRUCT. STRUCTURAL DW DISH WASHER TEXT TEXTURE D DRYER T & G TONGUE & GROOVE DBL. DOUBLE TYP. TYPICAL DN DOWN U.N.O. UNLESS NOTED OTHERWISE D.S. DOWNSPOUT WC WATER CLOSET E.O.S. EDGE OF SLAB WH WATER HEATER EQ. EQUAL WRGWB WATER RESISTANT EQUIV. EQUIPMENT GYPSUM WALL BOARD E.T.R. EXISTING TO REMAIN WD WOOD EXT. EXTERIOR W WASHER F.O.C. FACE OF COLUMN W/ WITH F.O.P. FACE OF POST F.O.S. FACE OF STUD F.O.S.W. FACE OF STEM WALL GWB GYPSUM WALL BOARD HT. HEIGHT INSTAL. INSTALLATION MANUF. MANUFACTURER MTL. METAL MTR. MATERIAL 3809 S 337TH STREET, FEDERAL WAY, WA 98001 i ._ •�t.'M.�nr nay.=V.�.. -�.�r4t KY-' � r^ .�•fT �`• PROJECT INFORMATION GOVERNING JURISDICTION : FEDERAL WAY, WA PARCEL #: 618143-0200 GOVERNING CODES: IRC 2018, WSEC 2018 UPC 2018 ZONING DISTRICT: RS9.6 CONSTRUCTION TYPE: VB NUMBER OF FLOORS: (2) ONE STORY BUILDING SQUARE FOOTAGE: EXISTING HOUSE 3,504 GROSS SQ FT GARAGE (ATTACHED, UNCONDITIONED) 441 GROSS SQ FT HOUSE 3,504 GROSS SQ FT GARAGE (ATTACHED, CONDITIONED) 441 GROSS SQ FT TOTAL SQUARE FEET CONDITIONED 3,945 GROSS SQ FT PROJECT VICINITY me NORTH tiar�iaaiui� ry uui 1 7 � W 517HIn51 American Ambition Equipment 8 dump... 10 yh M IG SNW Inc S 33"n41" ye 0M g¢ OVWCOITler Cc�aen.tnt Church laarle GGepel Church � w Fled Hor e Farm Northwest ,^ 9, $ Kidney Centers Light To The World n Aerotek ti' Evangeiica:l Church 30th LD GOP - WA q 7-Eleven SIw take In FIorric-rilary School � r A SwilchMlan Lake Gera ve Park it School � � z,xth .14 � CalPartland Washington �, Mater4s Division Office 51►`'r i s .xlaih ti $ 1961h SY } V s a+rrn World Vision y�w s "9t St Nc West Hy+lebos Wetlands Perk 60 S, Wild waves Theme and Water Park � ren;RoraF -i c::-oszc J r 5 36 Ott PROJECT SITE siSt s sae: 5r Lakeland North u — 5 � i51h 51 NV 5 3i..M s, $ 1*•4 „ k eV r South "Al , 1 f 'Y Nnev,3 The Outlet Collectim Seattle V DRAWING INDEX: GENERAL INFORMATION AG1.0 COVER SHEET / PROJECT INFORMATION ARCHITECTURAL A1.0 FLOOR PLAN & WORK FLOOR PLAN A2.0 PARTIAL BUILDING ELEVATION / SECTION / 2018 WSEC ALTERATIONS FORM RECEIVED 9/27/21 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT LEGAL DESCRIPTION: PARCEL NO: 618143-0200 NORTHLAKE RIDGE DIV 4 PLat Block: Plat Lot: 20 SITE ADDRESS: 3809 S 337TH STREET, FEDERAL WAY, WASHINGTON 98001 FRONT YARD STREET SETBACK: 20 FEET REAR YARD SETBACK: 5 FEET SIDE YARD SETBACK: 5 FEET PROJECTION EXCEPTION: EAVES, GUTTERS MAY EXTEND NOT MORE THAN (2) FEET INTO A SETBACK MAXIMUM HEIGHT: 30 FEET (NOTE* PROJECT DOES NOT MODIFY EXISTING EXTERIOR FOOTPRINT. NEW WORK IS REMODEL AND WILL NOT REQUIRE ANY EXTERIOR WORK.) ENERGY ENVELOPE WA. STATE ENERGY CODE; WAC 51-11; PRESCRIPTIVE METHOD FOR GROUP "R" OCCUPANCY, CLIMATE ZONE 4C (MARINE) PROJECT CLASSIFIED AS AN ALTERATION (REMODEL) AND USES THE 2018 WSEC(R) ALTERATIONS/REMODEL WORKSHEET. NO CREDITS REQUIRED WINDOWS: DOUBLE PANE INSULATED "U" = 0.30 PRESCRIBED (NEW WINDOW WILL BE 0.30 OR BETTER) DOORS: MINIMUM "U" = 0.30 PRESCRIBED (NO CHANGE REQUIRED, NO NEW EXTERIOR DOORS PROPOSED) PERIMETER WALLS: EXT. ABOVE GRADE = R-21 (NO CHANGE REQUIRED, NO NEW EXTERIOR WALLS PROPOSED) Algona PERIMETER R-49 PLENUM (NO CHANGE REQUIRED, NO NEW CEILINGS PROPOSED) FLOOR: R-30 (IN LIEU OF SLAB REPLACEMENT, PROJECT WILL HAVE R7.5 OR GREATER RIGID PER FW GARAGE CONVERSION CHECKLIST FLOOR INSULATION SECTION) FOUNDATION DEPTH: 2 FEET (NO CHANGE REQUIRED, NO MODIFICATION TO FOUNDATION PROPOSED) GRAVES + ASSOCIATES ARCHITECTURE I INTERIORS I PROJECT MANAGEMENT 3110 RUSTON WAY, SUITE E TACOMA, WA 98402 PHONE: 253-272-4214 z W o z� w C) oc W w O CD 00 F--4 % I— V Q Ln zv� w �Or-,Q �� UM� � J Uj CD I.0 Vtin M 0 w Q LL m oC Q Q w Q 0 a 2 a w Z zz o0 L w� �o 9w PROJECT: XXX PM: BC PERMIT SET 2021.09.23 6038 1 REGItIERED JON CARLTOI GRIVES STATE OF WA N TOP RE -USE OF DOCUMENTS THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF GRAVES + ASSOCIATES AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF GRAVES + ASSOCIATES. ARCHI I-ECTURAL GLNLRAt. AGI.O� EXISTING FIRST FLOOR PLAN SCALE: 1/4" = V-0" - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 21'-11" 2 �'I EXISTING GARAGE DOOR TO REMAIN BUT SHALL BE DECOMISSIONED. TRIM TRACK AND SUPPORT/LOCK GARAGE 2 DOOR TO PREVENT FUTURE \ \ \ \ OPERATION. INSTALL SIDE AND TOP A2.0 INSULATED VINYL WEATHER STRIPPING 2X6 STUD WALL @ 24" O.C. W/ BLACK WRB ON EXTERIOR SIDE. PROVIDE R-21 BATT INSULATION IN CAVITY. USE 4X6 P.T. SILL PLATE Field verify combustion air NEW FULL HEIGHT 2X4" STUD WALL @ 16" O.C. W/ R-13 BATT. INSULATION. VENT W.H. TO OUTSIDE/ PROVIDE FRESH AIR FOR COMBUSTION -4" NEW BATHROOM LIGHT FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS (LED) Space will be heated with 2 branch lines and registers coming off of trunk line above new bathroom 419 NET SQ. FT. OF NEWLY CONDITIONED SPACE ALL NEW LIGHT FIXTURES / SHALL BE HIGH -EFFICIENCY LAMPS (LED) 110 GARAGE NEW FLOOR ASSEMBLY. SEE ENLARGED SECTION REMOVE UTILITY SINK. RE-ROUTE EXISTING WATER SUPPLY TO NEW BATHROOM SINK. RE -USE EXISTING PLUMBING VENT NEW 2'-4" X 7'-0" WD CORE SWING DOOR M I I I L--J I I I Iok per table _ iR602.7(1) I I I -MODIFY EXISTING STEPS FOR NEW IF.F. ELEVATION. MAX RISER HEIGHT NOT MORE THAN 7.75" PER IRC R311.7.5.1 I O\ I SD/CM ID I e I 36X18 VANITY 109 PANTRY/ ME! LAUNDRY CV - -------------- ---------------- 0 o Z 2,-0„ g 21" MIN. R307.1 i/ �LO CONNECT NEW TOILET TO EXISTING - SANITARY SEWER. RUN NEW 2" VENT / -IV�2 N I I WAS M 91 an 1 EXISTING 2X6 STUD WA L W/ R-21 BATT INSULATION i TYP. @ ALL GARAGE EXT. WALLS) NEW 6o4o HORIZONTAL SLIDE WINDOW W/ 0.30 OR LESS U-FACTOR. PROVIDE (2) JACK STUDS AND (1) KING STUD EA. SIDE. INSTALL NEW 4X8 INSULATED HEADER TIGHT TO SHEATHING AND KING STUD Interconnected and hardwired INSTALL NEW COMBO SMOKE ALARM/CARBor MONOXIDE ALARM PER MO .5 OF THE 2018 IRC EXISTING 3o7o EGRESS DOOR RAISED TO MATCH NEW F.F. HEIGHT. PROVIDE NEW INSULATED 4X8 HEADER AT NEW DOOR OPENING NEW FULL HEIGHT 2X4" STI In WAI I (ny 1F" n n RECE VED EXISTING LAUNDRY ROOM WINDOW TO REMAIN 9 27/21 _ OF FEDERAL WiV C UNITY DEVELOP I In NT REF TO ROOF. TERMINATE NOT LESS THAN 6" ABOVE ROOF \----— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — --I-- NEW WORK PLAN SCALE: 1/2" = V-0" NEW BATHROOM EXHA ST L MEET NTS OF OF THE 201 IRC NT TO 50 cfm min GRAVES + ASSOCIATES ARCHITECTURE I INTERIORS I PROJECT MANAGEMENT 3110 RUSTON WAY, SUITE E TACOMA, WA 98402 PHONE: 253-272-4214 z LU o U Z Ln W 0 LU ,w 0 CD 00 % oc I— Cy)F--4 Q UlzV):-3: LU LL O , r--, > Q U r,10 � J W o oc LU Urr)m 00 LU Q L.L LU oQ a V) Z z o 0 >N w �o PROJECT: XXX PM: BC PERMIT SET 2021.09.23 KIEF::� 6038 1 REGIAERED JON CARL' STATE OF' RE -USE OF DOCUMENTS THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF GRAVES + ASSOCIATES AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF GRAVES + ASSOCIATES. FLOOR PLAN A1,00 PARTIAL SIDE ELEVATION (NORTHEAST) SHOWING NEW WORK SCALE: 1/4" = V-0" INSTALL NEW FLOOR O/ 3/4" T&G PLYWOOD (GLUED AND SCREWED) O/ 2X P.T. SLEEPERS 24" O.C.. BLOCK EACH WAY EVERY 5'-0". INFILL 1.5" RIGID IN BETWEEN SLEEPERS (R7.5 MIN). IF RIPPING BOTTOM OF SLEEPER TO MATCH SLOPE, TREAT CUT SIDE W/ WOOD PRESERVATIVE. SLEEPERS SHALL BE ANCHORED TO EXISTING S.O.G. USING CORROSION RESISTANT FASTENERS 210 EXISTING GARAGE DOOR TO REMAIN BEDROOM BUT SHALL BE DECOMISSIONED. TRIM TRACK AND SUPPORT/LOCK GARAGE DOOR TO PREVENT FUTURE OPERATION 110 GARAGE PARTIAL SECTION SHOWING NEW WORK SCALE: 1/4" = V-0" 'TGRESS � III III III 3 ESS II IIII Ilk IIII 109 PANTRY/ LAUNDRY EMERGENCY ESCAPE AND RESCUE OPENING (EGRESS). MINIMUM NET CLEAR OPENING OF 5.7 SQ. FT. REQUIRED (11.14 SQ. FT. PROVIDED) MAX WINDOW SILL HEIGHT NOT MORE THAN 44" A.F.F. (36" PROVIDED) Alterations Worksheet - 2018 Washington State Energy Code Project Information Contact Information Abucar Residence Garage Conversion Ben Childs / Graves+Associates 3809 S 337th Street 253-279-0444 / bchilds@gravesassoc.com Federal Way, WA 98001 The WSEC requirements for alterations are located in Chapter 5 of the code text. Alterations (remodels) do not need to obtain energy credits from Table R406.3 Additions must meet the requirements for new construction. This includes nonconditioned space being altered to become conditioned space. Will the wall cavities be exposed? r- Yes v No If yes: Exposed wall cavities must be insulated - 2 X 4 wall studs require R-15 insulation 2 X 6 wall studs require R-21 insulation Will the roof/ceiling framing cavities or attic be exposed? Yes v No If yes: Exposed roof/ceiling assemblies must be insulated - Vaulted ceilings: Insulate to the full depth of the framing member while allowing for the minimum 1" ventilated space Flat ceilings: Install R-49 insulation or what the attic space can accommodate based on the roof pitch Will the floor framing cavities be exposed? Yes No If yes: Exposed floor cavities must be insulated to R-3 R7.5 MIN. PROVIDED PER CITY OF FEDERAL WAY GARAGE CONVERSION CHECKLIST Are the windows and/or doors being replaced? Yes No (includes both window or door and frames) If yes: New windows and doors must have an area weighted average U-factor of <_0.30 Will the heating or cooling system be replaced? Yes v No If yes: New equipment must meet current requirements and ducts need to be tested Will the hot water system be altered? Yes v No If yes: New water heating equipment must meet current code requirements Are more than 50% of the light fixtures being changed? -, Yes v No If yes: 90% of all lamps must be high efficacy (LED or CFL) 2018 WSEC ALTERATIONS WORKSHEET SCALE: N.T.S. R503.1.1 Building envelope. Building envelope assemblies that are part of the alteration shall comply with Section R402.1.1 or R402.1.4, Sections R402.2.1 through R402.2.11, R402.3.1, R402.3.2, R402.4.3 and R402.4.4. Exception: The following alterations need not comply with the requirements for new construction provided the energy use of the building is not increased: 1. Storm windows installed over existing fenestration. 2. Existing ceiling, wall or floor cavities exposed during construction provided that these cavities are filled with insulation. 2x4 framed walls shall be insulated to a minimum of R-15 and 2x6 framed walls shall be insulated to a minimum of R-21. 3. Construction where the existing roof, wall or floor cavity is not exposed. 4. Roof recover. 5. Roofs without insulation in the cavity and where the sheathing or insulation is exposed during reroofing shall be insulated either above or below the sheathing. 6. Surface -applied window film installed on existing single pane fenestration assemblies to reduce solar heat gain provided the code does not require the glazing fenestration to be replaced. R503.1.1.1 Replacement fenestration. Where some or all of an existing fenestration unit is replaced with a new fenestration product, including sash and glazing, the replacement fenestration unit shall meet the applicable requirements for U-factor and SHGC in Table R402.1.1. Where more than one replacement fenestration unit is being installed, an area - weighted average of the U-factor and SHGC of all replacement fenestration shall be permitted to be used to demonstrate compliance. R503.1.2 Heating and cooling systems. New heating, cooling and duct systems that are part of the alteration shall comply with Section R403. Exceptions: 1. Where ducts from an existing heating and cooling system are extended, duct systems with less than 40 linear feet in unconditioned spaces shall not be required to be tested in accordance with Section R403.2.2. 2. Existing duct systems constructed, insulated or sealed with asbestos. R502.1.1.2 Heating and cooling systems. New heating, cooling and duct systems that are part of the addition shall comply with Section R403. Exception: The following need not comply with the testing requirements of Section R403.3.3: 1. Additions of less than 750 square feet. 2. Duct systems that are documented to have been previously sealed as confirmed through field verification and diagnostic testing in accordance with procedures in WSU RS-33. 3. Ducts with less than 40 linear feet in unconditioned spaces. 4. Existing duct systems constructed, insulated or sealed with asbestos. R503.1.3 Service hot water systems. New service hot water systems that are part of the alteration shall comply with Section R403.5. R503.1.4 Lighting. New lighting systems that are part of the alteration shall comply with Section R404.1. Exception: Alterations that replace less than 50 percent of the luminaires in a space, provided that such alterations do not increase the installed interior lighting power. R503.2 Change in space conditioning. Any nonconditioned or low -energy space that is altered to become conditioned space shall be required to be brought into full compliance with this code. RECEIVED 9/27/21 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT GRAVES + ASSOCIATES ARCHITECTURE I INTERIORS I PROJECT MANAGEMENT 3110 RUSTON WAY, SUITE E TACOMA, WA 98402 PHONE: 253-272-4214 Z LU o U z� W 0 W w CD O CD 00 Ili >�C I-- Cy) Q UlzV� LU Or.O�Q U r'10 LU CD cc LU V � M0 LULL ryoo LU Q0 o a a z o0 o � a > Nw E o � MMMIW PROJECT: XXX PERMIT SET 2021.09.23 6038 1 REGItIERED JON CARLTOI GRIVES STATE OF WA N TOP RE -USE OF DOCUMENTS THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF GRAVES + ASSOCIATES AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF GRAVES + ASSOCIATES. . E:W::::: VLR I ICAL I'LANS A2.0