Loading...
21-101800-CO-Administrative Decision-06-01-2021-V140k CITY OF 40'::ttw*m=�0- Federal Way RESUBMITTED Mar 24 2021 CITYOF FEDERALWAY Eligible Facilities Request COMMUNITY DEVELOPMENT DEPARTMENT OF COMMUNITY DEVELOPMENT 33325 8th Avenue South Federal Way, WA 98003-6325 253-835-2607; Fax 253-835-2609 www.citvoffederalway.com FILE NUMBER 2J-JDfJ&9 "p0-fin - AD Date Applicant NAME PRIMARY PHONE Vinh Dinh - Infinigy on behalf of ATC and T-Mobile Cell 206.295.5926 MAILING ADDRESS E-MAIL 21806 Poplar Way vdinh@infinigy.com CITY Brier STATE WA zip 98036 FAX Site Address: 34301 9th Ave S, Federal Way, WA 98003 Parcel#: 2021049157 Project Name: 91531 - 34301 9th Avenue South/ TMO SE04723A ELIGIBLE FACILITIES SUBMITTAL REQUIREMENTS Use this checklist to help gather all of the required information and documents in order to submit an eligible facilities request pursuant to Federal Way Revised Cade (FWRC) 4.24.020. Please note, incomplete applications will not be accepted. Submitted ® Completed Eligible Facilities Checklist (following) 0 Check, cash, Visa/MasterCard for applicable fees ® Site Plan —Three Copies 1. Minimum plan size of 11" X 17". 2. North arrow. 3. Drawn to scale, dimensioned, and labeled. 4. Building footprint(s), including square footage. 5. Location and dimensions of existing structures, property lines, sidewalks, easements, street edges, mechanical equipment, fencing, rockeries, and retaining walls. 0 Elevation — Three Copies 1. Minimum plan size of 11" x 17". 2. Drawn to scale, dimensioned, and labeled. 3. Front, rear, and side (labeled as north, south, east, and west) building elevation of existing and proposed structures. 4. Height of structure calculations. 5. Roof -top and ground based mechanical equipment screen details. Bulletin 081—September 24, 2018 Page 1 of 3 k:\Handouts\Eligible Facilities Request ELIGIBLE FACILITIES CHECKLIST Proposed modifications to an existing tower or base station must meet at least one of the three threshold criteria below for an eligible facilities request. For definitions please refer to FWRC 19.256.020. Check all that apply. Collocation of new transmission equipment Removal of transmission equipment X Replacement of transmission equipment Is the proposed modification a substantial change as defined in FWRC 19.256.020? To determine, fill in the appropriate information below. If the application does not meet all of the criteria below, then the project does not qualify as an eligible facility and it is unnecessary to complete this form. To determine the correct review process, refer to FWRC Chapter 19.256, "Wireless Communication Facilities." Criteria 1 • For towers other than towers in the public rights -of -way, it does not increase the height of the tower by more than 10 percent, or by the height of one additional antenna array, with separation from the nearest existing antenna not to exceed 20 feet, whichever is greater. • For other eligible support structures, it does not increase the height of the structure by more than 10 percent, or more than 10 feet, whichever is greater. Existing height of the structure: 120 (ft/ in) Proposed height of the structure: no change (ft/ in) Distance of proposed array from nearest array: no change (ft/ in) Criteria 2 • For towers other than towers in the public rights -of -way, it does not involve adding an appurtenance to the body of the tower that would protrude from the edge of the tower more than 20 feet, or more than the width of the tower structure at the level of the appurtenance, whichever is greater. • For other eligible support structures, it does not involve adding an appurtenance to the body of the structure that would protrude from the edge of the structure by more than six feet. What is the existing width of the structure at the level of the appurtenance? 2 ft (ft/ in) What is the proposed distance the appurtenance will protrude from the structure? no change (ft/ in) Criteria 3 • For any eligible support structure, it does not involve installation of more than the standard number of new equipment cabinets for the technology involved, but not to exceed four cabinets; or, • For towers in the public rights -of -way and base stations, it does not involve installation of any new equipment cabinets on the ground if there are no pre-existing ground cabinets associated with the structure; or • It does not involve installation of ground cabinets that are more than 10 percent larger in height or overall volume, than any other ground cabinets associated with the structure. How many new equipment cabinets are proposed? 2 new cabinets proposed (3 total) Bulletin 081—September 24, 2018 Page 2 of 3 k:\Handouts\Eligible Facilities Request Criteria 4 • For all existing facilities, it does not entail any excavation or deployment outside the current site. Will any excavation or equipment installation occur outside of the current site of the structure? ❑ Yes N No Criteria 5 • For all existing facilities, the modification does not defeat the concealment elements of the eligible support structure. Please describe any existing and proposed concealment elements: non existing - No change Will the proposal increase the visibility of the facility? ❑ Yes ® No Criteria 6 • The modification complies with conditions associated with the siting approval of the construction, or modification of the eligible support structure or base station equipment; provided, however, that this limitation does not apply to any modification that is noncompliant only in a manner that would not exceed the thresholds identified above. Identify known conditions associated with previous approvals of the existing facility. none -known Will the proposal violate any of the above conditions? ❑ Yes ® No If yes, explain: To Be Completed By Staff Is this an Eligible Facility Request? ® Yes ❑ No Does the proposal constitute a substantial change? ❑ Yes ® No In accordance with FWRC 4.24.020, this application is hereby: ❑X Approved ❑ Denied 8ria� Da v`t - Director, Community Development Department Digitally Signed April 15, 2021, at 4:41 PM Date Bulletin 081—September 24, 2018 Page 3 of 3 k:\Handouts\Eligible Facilities Request 21-100691 -Plan-03-09-2021 -V1 T Mobile- T-MOBILE SITE NUMBER: SE04723A ATC #: T-MOBILE SITE NAME: FEDERAL WAY DISTRIBUTION CENTERS SITE ADDRESS: SITE TYPE: MONOPOLE TOWER HEIGHT: 120'-011 SE04723A—Federal Way Distribution Centers —Sprint Retain_PCD_FSA_02.11.21 1 SITE INFORMATION 1 PROPERTY INFORMATION: SITE ADDRESS: 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 COUNTY: KING LATITUDE (NAD83): 47" 17' 49.9" N (47.29724525°) LONGITUDE (NAD83): 122° 19' 36.5" W (-122.32678328°) GROUND ELEVATION (NAVD88): t295' AMSL JURISDICTION: CITY OF FEDERAL WAY APN: 202104-9157 ZONING: C OCCUPANCY CLASSIFICATION: U LEGAL DESCRIPTION: SEE SHEET A-1 CONSTRUCTION INFORMATION: AREA OF CONSTRUCTION: TYPE OF CONSTRUCTION: 1113 PROPOSED USE: UNMANNED TELECOMMUNICATIONS FACILITY HANDICAP REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS NOT REQUIRED. PROPERTY OWNER: COMPANY: USPS SEATTLE NDC ADDRESS: 34301 9TH AVE., S. CITY, STATE, ZIP: FEDERAL WAY, WA 98003 TOWER OPERATOR: COMPANY: AMERICAN TOWER CORPORATION ADDRESS: 10 PRESIDENTIAL WAY CITY, STATE, ZIP: WOBURN, MA 01801 CONTACT: TIFFANY PRETTY (PROJECT MANAGER) PHONE: (949)447-2303 E-MAIL: tiffany.pretty@americantower.com APPLICANT: COMPANY: T-MOBILE ADDRESS: 19807 NORTH CREEK PKWY N CITY, STATE, ZIP: BOTHELL, WA 98011 CONTACT: MIKE REED PHONE: E-MAIL: mike.reed161@t-mobile.com PROJECT TEAM 1 ARCHITECTURAL & ENGINEERING: COMPANY: INFINIGY ENGINEERING, PLLC CONTACT: PAULDANNEBERG PHONE: (206) 375-3798 E-MAIL: pdanneberg@infinigy.com SITE ACQUISITION: COMPANY: INFINIGY SOLUTIONS, LLC CONTACT: VINH DINH PHONE: (206) 295-5926 E-MAIL: vdinh@infinigy.com ATC PROJECT MANAGER: COMPANY: AMERICAN TOWER CORPORATION ADDRESS: 10 PRESIDENTIAL WAY CITY, STATE, ZIP: WOBURN, MA 01801 CONTACT: TIFFANY PRETTY (PROJECT MANAGER) PHONE: (949) 447-2303 E-MAIL: tiffany.pretty@americantower.com SHEET INDEX SHEET DESCRIPTION T-1 TITLE SHEET T-2 SPECIFICATIONS & NOTES SPECIFICATIONS & NOTES T-3 A-1 OVERALL SITE PLAN ENLARGED SITE PLANS A-2 A-3 SOUTH ELEVATIONS A-4 ANTENNA PLAN & RF SCHEDULE A-4.1 RF PLUMBING DIAGRAM A-4.2 AEHC CABLING DIAGRAM A-5 EQUIPMENT DETAILS A-6 EQUIPMENT DETAILS A-6.1 EQUIPMENT DETAILS A-6.2 EQUIPMENT DETAILS A-7 EQUIPMENT DETAILS A-8 GENERATOR DETAILS E-1 UTILITY ROUTING PLAN & DETAILS E-1.1 ELECTRICAL DIAGRAMS E-1.2 ELECTRICAL DIAGRAMS G-1 SCHEMATIC GROUNDING PLANS & NOTES G-2 GROUNDING DETAILS CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. el APPROVALS THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS & AUTHORIZE THE SUBCONTRACTOR TO PROCEED WITH CONSTRUCTION AS DESCRIBED HEREIN. ALL CONSTRUCTION DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT & ANY CHANGES OR MODIFICATIONS THEY MAY IMPOSE. APPROVAL: SIGNATURE: DATE: PROJECT MANAGER SITE ACQUISITION CONSTRUCTION MANAGER SITE OWNER RF ENGINEER uJ DEVELOPMENT MANAGER m CONSTRUCTION MANAGER 0 OPS MANAGER ~ REGULATORY REVIEW PROJECT MANAGER COUNTY: JURISDICTION: LAT: 47' 17' 49.9" N Garden Terrace Healthcare Center 'i �e &p 14 Federal Way Regional Pubs1C U... ¢S 15 P :er Lake I SCM00i V 91531 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 KING CITY OF FEDERAL WAY LONG: 1220 19' 36.511 W VICINITY MAP SITE Fraroscar. Pharmacy Providence Community Corrections S 243rd St P8-- sk_' DRIVING DIRECTIONS FROM T-MOBILE LOCAL OFFICE (19807 NORTH CREEK PKWY, BOTHELL, WA 98011 ): DEPART SOUTH ON N CREEK PKWY, TURN RIGHT ONTO NE 195TH ST, NORTHCREEK CHEVRON ON THE CORNER, TAKE RAMP LEFT FOR 1-405 S, KEEP LEFT TO STAY ON 1-405 S, TAKE RAMP FOR 1-5 SOUTH TOWARD PORTLAND, TAKE RAMP RIGHT AND FOLLOW SIGNS FOR WA-18 WEST, KEEP STRAIGHT ONTO S 348TH ST, TURN RIGHT ONTO 9TH AVE S, TURN LEFT, ARRIVE AT: 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003. 1 CODE COMPLIANCE 1 ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE LATEST EDITIONS OF THESE CODES. 1. 2015 INTERNATIONAL BUILDING CODE 2. 2015 INTERNATIONAL MECHANICAL CODE 3. 2015 INTERNATIONAL FIRE CODE 4. 2015 UNIFORM PLUMBING CODE 5. 2017 NATIONAL ELECTRICAL CODE 6. 2015 INTERNATIONAL FUEL GAS CODE 7. TIA-EIA-222-G OR LATEST EDITION 8. ASCE 7-10 9. NFPA 780 - LIGHTNING PROTECTION CODE 10. ANY OTHER NATIONAL OR LOCAL APPLICABLE CODES, MOST RECENT EDITION 11. LOCAL AMENDMENTS TO THE ABOVE, WHERE APPLICABLE 12. CITY/COUNTY ORDINANCES 13. LIFE SAFETY CODE NFPA-101 RESUBMITTED APPROVED m PLANNING Mar 24 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Know what's below. CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Cal before you dig. By: CSkadsen ww—.1181 1 .- 1 PROJECT DESCRIPTION 1 T-MOBILE PROPOSES TO COLLOCATE ON AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY AS FOLLOWS: TOWER SCOPE OF WORK: • REMOVE ALL SPRINT ANTENNAS, RRUS & DIPLEXERS • INSTALL (3) FFVV-65C-R3-V1 & (3) AEHC PANEL ANTENNAS • INSTALL (3) AHLOA & (3) AHFIG RRU'S • INSTALL (2) HCS 2.0 PENDANTS • INSTALL (2) FD21206-48S55-XXX PENDANT STYLE HYBRID CABLES GROUND SCOPE OF WORK: • REMOVE ALL SPRINT EQUIPMENT AND EXISTING CONCRETE PAD • INSTALL 10'-0"X6'-0" ICE CANOPY OVER NEW 15'-0"X10'-0" CONCRETE PAD • INSTALL (1) HPL3 POWER CABINET & (1) LB3 BATTERY CABINET • INSTALL (2) AMIA, (2) ASIB, (2) ASIK, (1) FSMF, (3) ABIA, (4) ABIL, (1) CSR IXRE ROUTER, & (1) VOLTAGE BOOSTER W/ EXTRA AMPLIFIER INSIDE HPL3 POWER CABINET • INSTALL (1) 25 KW DIESEL GENERATOR • INSTALL AN H-FRAME WITH UTILITY EQUIPMENT (ATS, TELCO BOX, ETC.) • INSTALL (1) GPS ANTENNA, & (2) HCS 2.0 JUNCTION BOXES • INSTALL (2) LED LIGHTS WITH TIMER DESIGN IS BASED ON: ATC APPLICATION ID ----, REV. #0 RFDS VERSION 1, DATED 12/07/2020 (CONFIG. 56790EZ_SR_T, 56790EZR SIR THESE PLANS HAVE BEEN DEVELOPED FOR THE CONSTRUCTION OF AN UNMANNED TELECOMMUNICATIONS FACILITY OWNED OR LEASED BY T-MOBILE IN ACCORDANCE WITH THE PROVIDED SCOPE OF WORK, INCORPORATED IN THE PLANS BY INFINIGY. THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED & SIGNED, & ACCOMPANIED BY A PASSING STRUCTURAL STABILITY ANALYSIS FOR THE STRUCTURE AND MOUNT PREPARED BY A LICENSED PROFESSIONAL ENGINEER. T Mobile 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 111L AMERICAN TOWER CORPORATION INFINIGY8 FROM ZERO TO INFINIGY the solutions are endless BELLEVUE, WA 98004 T-MOBILE SITE: SE04723A FEDERAL WAY DISTRIBUTION CENTERS ATC SITE: 91531 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 KING COUNTY 120'-0" MONOPOLE DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION OA/OC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD TITLE: TITLE SHEET SHEET NUMBER: I REVIOSION: T-1 THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. A. GENERAL C. COATING SYSTEM SPECIFICATIONS 1. ALL PAINT PRODUCT LINES SHALL BE SHERWIN WILLIAMS 1. DTM ACRYLIC COATING (SERIES B66) BY SHERWIN UNLESS SPECIFICALLY NOTED OTHERWISE BY T-MOBILE. WILLIAMS CO. 1MIL DFT PER COAT APPLIED IN TWO COATS OVER DTM BONDING PRIMER (B66A50). 2. CONTRACTOR SHALL PREPARE ALL SURFACES AND APPLY ALL FINISHES PER LATEST EDITION OF MANUFACTURER'S SPECIFICATIONS. 3. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS REGARDING SUFFICIENT DRYING TIME BETWEEN COATS WITH PROVISIONS AS RECOMMENDED BY MANUFACTURER FOR EXISTING WEATHER CONDITIONS. 4. FINISH COLOR AND TEXTURE OF ALL PAINTED SURFACES SHALL MATCH EXISTING ADJACENT SURFACES UNLESS OTHERWISE NOTED BY T-MOBILE. 5. ALL PAINT MATERIAL DATA SHEETS SHALL BE PROVIDED TO THE T-MOBILE CONSTRUCTION MANAGER. 6. PREPARE PREVIOUSLY PAINTED SURFACE BY LIGHT SANDING WITH 400 GRIT SANDPAPER AND NON -HYDROCARBON WASH. PREPARE GALVANIZED SURFACES BY ACID ETCH OR SOLVENT CLEANING IN ACCORDANCE WITH SSPC-SP1. 7. FURNISH DROP CLOTHS, SHIELDS, MASKING AND OTHER PROTECTIVE METHODS TO PREVENT SPRAY OR DROPPINGS FROM DAMAGING ADJACENT SURFACES AND FACILITIES. 8. APPLY PAINT BY AIRLESS SPRAY, SANDING LIGHTLY BETWEEN EACH SUCCEEDING ENAMEL COAT ON FLAT SURFACES. APPLY MATERIAL TO ACHIEVE A COATING NO THINNER THAN THE DRY FILM THICKNESS INDICATED. 9. APPLY BLOCK FILTER TO CONCRETE BLOCK CONSTRUCTION AND ENSURE COMPLETE COVERAGE WITH PORES COMPLETELY FILLED. 10. CONTRACTOR SHALL CORRECT RUNS, SAGS, MISSES AND OTHER DEFECTS INCLUDING INADEQUATE COVERAGE AS DIRECTED BY THE T-MOBILE CONSTRUCTION MANAGER. REPAINT AS NECESSARY TO ACHIEVE SURFACES THAT ARE SMOOTH, EVENLY COATED WITH UNIFORM SHEEN AND FREE FROM BLEMISHES. 1=�1 111,1111,2[C1110109=1 1. PAINT THE FOLLOWING MATERIALS AND SYSTEMS CHECKED BELOW WITH THE COATING SYSTEM INDICATED. PAINTING SCOPE SURFACE TO BE PAINTED COATING PAINT DO NOT N/A SYSTEM PAINT BTS UNIT X ALL EQUIPMENT & CABINETS X OTHER THAN THE BTS UNIT ANTENNA COVERS, TILT BRACKETS, MOUNTING BRACKETS AND ASSOCIATED HARDWARE, CABLE AND CABLE SEE SEE COVERS EXPOSED TO VIEW, PLANS PLANS EXPOSED CONDUIT AND HANGERS, ETC. FLASHING UNITS, METAL TRIM X AND OTHER METAL SURFACES STUCCO, CONCRETE, CONCRETE BLOCK AND X CEMENTIOUS TYPE FINISH SYSTEMS. PLYWOOD, LUMBER AND WOOD TRIM INCLUDING THE BACK SIDE X OF ALL SCREEN WALLS DRYWALL X CONCRETE POLES X METAL POLES AND METAL POLE X STAND-OFF 2. 100% ACRYLIC, LATEX COATING EQUIVALENT TO A-100 (SERIES A-82) BY SHERWIN WILLIAMS CO. 1 MIL DFT PER COAT APPLIED IN TWO COATS OVER SPECIFIED PRIMER. D. PAINT & PRIMER ANTENNAS PRIMER - KEM AQUA E61-W525 TOPCOAT - COROTHANE II B65W200/B6OV22 BTS CABINET PRIMER - KEM AQUA E61-W525 TOPCOAT - COROTHANE II B65W200/B6OV22 COAXIAL JUMPER CABLES PRIMER - AS REQUIRED FOR ADHESION. APPLY ONE COAT OF KEM AQUA WATER REDUCIBLE PRIMER E61 W25 REDUCED 25% TOPCOAT - 2 COATS COROTHANE II POLYURETHANE B65W200/B6OV2 RAW STEEL PRIMER - KEM BOND HS B50WZ4, DMT ACRYLIC PRIMER TOPCOAT - 2 COATS COROTHANE II POLYURETHANE B65W200/B6OV2 GALVANIZED METAL ACID ETCH WITH COMMERCIAL ETCH OR VINEGAR PRIMER COAT AND FINISH COAT (GALVITE HIGH SOLIDS OR DTM PRIMER/FINISH) STAINLESS STEEL PRIMER - OTM WASH PRIMER, B71Y1 TOPCOAT - 2 COATS COROTHANE II POLYURETHANE B65W200/B6OV2 PRE -PRIMED STEEL TOUCH UP ANY RUST OR UN -PRIMED STEEL WITH KEM BOND HS, SSOWZ4 ALUMINUM & COPPER PRIMER - DTM WASH PRIMER, B71Y1 TOPCOAT - 2 COATS COROTHANE II POLYURETHANE B65W200/B6OV2 CONCRETE MASONRY PRIMER - PRO MAR EXTERIOR BLOCK FILLER TOPCOAT - 2 COATS A-100 LATEX HOUSE & TRIM, SHEEN TO MATCH CONCRETE STUCCO(EXISTING) 2 COATS A-100 LATEX HOUSE & TRIM, SHEEN TO MATCH STUCCO PRIMER - PRO MAR MASONRY CONDITONER B-46-W21000 TOPCOAT - SUPERPAINT A-80 SERIES A-89 SATIN A-84 GLOSS WOOD PRIMER - A-100 EXTERIOR ALKYD W009D PRIMER Y-24W20 TOPCOAT - 2 COATS A-100 LATEX HOUSE & TRIM SHEEN TO MATCH ADJACENT SURFACES 1. THE LATEST EDITION OF THE AMERICAN INSTITUTE OF ARCHITECTS DOCUMENT A201 "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION" ARE INCLUDED IN THESE SPECIFICATIONS AS IF COMPLETELY REPRODUCED HEREIN. 2. THIS FACILITY IS AN UNOCCUPIED PCS TELECOMMUNICATIONS SITE AND IS EXEMPT FROM ADA ACCESS REQUIREMENTS. 3. PRIOR TO SUBMISSION OF BIDS, THE CONTRACTORS PARTICIPATING SHALL VISIT THE JOB SITE WITH THE CONSTRUCTION AND CONTRACT DOCUMENTS TO CONFIRM THAT THE PROJECT CAN BE ACCOMPLISHED AS DESIGNED HEREIN, AS WELL AS TO FAMILIARIZE THEMSELVES WITH ALL FIELD CONDITIONS AFFECTING THE PROPOSED PROJECT INCLUDING DEMOLITION, ELECTRICAL, MECHANICAL AND STRUCTURAL INSTALLATIONS PRIOR TO PROCEEDING WITH CONSTRUCTION. SHOULD ANY ERRORS, OMISSION, OR DISCREPANCIES BE FOUND, THE GENERAL CONTRACTOR SHALL IMMEDIATELY NOTIFY IN WRITING, THE T-MOBILE CONSTRUCTION MANAGER AND THE ARCHITECT. 4. IN THE EVENT OF DISCREPANCIES WITHIN THESE DRAWINGS, THE CONTRACTOR SHALL INCLUDE THE MORE COSTLY OR EXTENSIVE WORK IN THE BID, UNLESS SPECIFICALLY DIRECTED OTHERWISE BY T-MOBILE. IF A DISCREPANCY EXISTS AND THE PROJECT MANAGER AND ARCHITECT ARE NOT NOTIFIED, THE GENERAL CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL COSTS INCURRED TO REPAIR OR CORRECT ALL PROBLEMS THAT RESULT. 5. THESE DRAWINGS SHALL NOT BE SCALED AS THESE DRAWINGS ARE INTENDED TO BE FOR DIAGRAMMATIC PURPOSES ONLY. FIGURED DIMENSIONS HAVE PRECEDENCE OVER DRAWING SCALE AND DETAIL DRAWINGS HAVE PRECEDENCE OVER SMALL SCALE DRAWINGS. CONTRACTOR SHALL CHECK THE ACCURACY OF ALL DIMENSIONS IN THE FIELD. UNLESS SPECIFICALLY NOTED, DO NOT FABRICATE ANY MATERIALS, OR BEGIN ANY CONSTRUCTION UNTIL THE ACCURACY OF DRAWING DIMENSIONS HAS BEEN VERIFIED AGAINST ACTUAL FIELD DIMENSIONS. 6. THE CONTRACTOR SHALL INCLUDE IN HIS OR HER BID ALL MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE THE WORK AS INDICATED OR IMPLIED BY THESE DRAWINGS. 7. CONTRACTOR SHALL NOTIFY THE T-MOBILE CONSTRUCTION MANAGER, THE PROPERTY OWNER AND THE ARCHITECT IF ANY DETAILS ARE CONSIDERED IMPRACTICAL, UNSUITABLE, UNSAFE, NOT WATERPROOF OR NOT WITHIN CUSTOMARY TRADE PRACTICE. IF WORK IS PERFORMED, IT WILL BE ASSUMED THAT THERE IS NO OBJECTION TO ANY DETAIL. DETAILS ARE INTENDED TO SHOW THE END RESULT OF THE DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB CONDITIONS, AND SHALL BE INCLUDED AS PART OF THE WORK. 8. EXISTING ELEVATIONS AND LOCATIONS SHALL BE VERIFIED BY THE CONTRACTOR BEFORE CONSTRUCTION. IF THEY DIFFER FROM THOSE SHOWN ON THE PLANS, THE CONTRACTOR SHALL NOTIFY THE T-MOBILE CONSTRUCTION MANAGER AND THE ARCHITECT SO THAT MODIFICATIONS CAN BE MADE BEFORE PROCEEDING WITH THE WORK. 9. THE CONTRACTOR SHALL VERIFY ALL TELEPHONE & RADIO EQUIPMENT LAYOUTS, SPECIFICATIONS, PERFORMANCE, INSTALLATION AND FINAL LOCATIONS WITH T-MOBILE CONSTRUCTION MANAGER PRIOR TO BEGINNING WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL WORK WITH ERICSSON RADIO SYSTEMS. 10. ALL SYMBOLS & ABBREVIATIONS USED ON THESE DRAWINGS ARE CONSIDERED CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING THEIR EXACT MEANING, THE T-MOBILE CONSTRUCTION MANAGER AND THE ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION BEFORE THE CONTRACTOR PROCEEDS WITH THE WORK. 11. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES AND INSPECTIONS NECESSARY FOR PERFORMANCE OF THE WORK AND INCLUDE THOSE IN THE COST OF THE WORK TO T-MOBILE. 12. THE CONTRACTOR SHALL PROVIDE CONTINUOUS SUPERVISION AND DIRECT ALL WORK WHILE ANY SUBCONTRACTORS OR WORKERS ARE ONSITE, USING HIS OR HER BEST SKILL AND ATTENTION. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, SEQUENCES, AND COORDINATION OF ALL PORTIONS OF THE CONTRACTED WORK. 13. WORKMANSHIP THROUGHOUT SHALL BE OF THE BEST QUALITY OF THE TRADE INVOLVED, AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM REFERENCE STANDARDS FOR QUALITY AND PROFESSIONAL CONSTRUCTION PRACTICE: NRCA NATIONAL ROOFING CONTRACTORS ASSOCIATION O'HARE INTERNATIONAL CENTER 10255 W. HIGGINS ROAD, SUITE 600 ROSEMONT. IL 60018-5607 SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION 4201 LAFAYETTE CENTER DRIVE CHANTILLY, VA 20151-1219 IILP INTERNATIONAL INSTITUTE FOR LATH AND PLASTER 820 TRANSFER ROAD ST. PAUL, MN 55114-1406 14. INSTALL ALL EQUIPMENT AND MATERIALS PER THE LATEST EDITION OF THE MANUFACTURER'S INSTALLATION SPECIFICATIONS UNLESS OTHERWISE INDICATED BY T-MOBILE, OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 15. THE CONTRACTOR SHALL VERIFY, COORDINATE, AND PROVIDE ALL NECESSARY BLOCKING, BACKING, FRAMING, HANGERS OR OTHER SUPPORTS FOR ALL ITEMS. 16. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL GIVE ALL REQUIRED CONSTRUCTION NOTICES AND SHALL COMPLY WITH ALL APPLICABLE LOCAL CODES, REGULATIONS, LAWS AND ORDINANCES, AS WELL AS THE STATE DEPARTMENT OF INDUSTRIAL RELATIONS REGULATIONS, INCLUDING BUT NOT LIMITED TO THE DIVISION OF OCCUPATIONAL SAFETY AND HEALTH (OSHA). 17. THE CONTRACTOR SHALL PROTECT ALL PROPERTY FROM DAMAGE THAT MAY OCCUR DURING CONSTRUCTION. ANY DAMAGE TO NEW AND EXISTING FINISHES, CONSTRUCTION, STRUCTURE, LANDSCAPING, CURBS, STAIRS, OR EQUIPMENT, ETC. SHALL BE IMMEDIATELY REPAIRED OR REPLACED TO THE SATISFACTION OF T-MOBILE AND THE PROPERTY OWNER'S REPRESENTATIVE, AT THE EXPENSE OF THE CONTRACTOR. 18. THE CONTRACTOR SHALL BE RESPONSIBLE FOR, AND SHALL REPLACE OR REMEDY, ANY FAULTY, IMPROPER, OR INFERIOR MATERIALS OR WORKMANSHIP OR ANY DAMAGE WHICH SHALL APPEAR WITHIN ONE YEAR AFTER THE COMPLETION AND ACCEPTANCE OF THE WORK BY T-MOBILE UNDER THIS CONTRACT. 19. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO PROTECT AND LOCATE, OR CONTACT AN OUTSIDE AGENCY TO LOCATE, ALL EXISTING UTILITIES REGARDLESS OF WHETHER OR NOT SHOWN HEREIN. THE CONTRACTOR SHALL BEAR ALL EXPENSES FOR THE REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED IN CONJUNCTION WITH THE EXECUTION OF WORK. 20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE PROJECT SITE WHILE THE JOB IS IN PROGRESS AND UNTIL THE JOB IS COMPLETED AND ACCEPTED BY T-MOBILE. 21. THE CONTRACTOR SHALL PROVIDE TEMPORARY WATER, POWER AND TOILET FACILITIES AS REQUIRED BY THE PROPERTY OWNER, T-MOBILE, AND THE CITY OR GOVERNING AGENCY. 22. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REDLINING THE CONSTRUCTION DOCUMENTS TO ILLUSTRATE THE AS -BUILT CONDITION OF THE SITE. THIS SHALL BE DONE AFTER THE SITE HAS BEEN AWARDED FINAL INSPECTION BY THE RESPONSIBLE BUILDING AGENCY. ONE SET OF REDLINED DRAWINGS SHALL BE PROVIDED TO THE T-MOBILE CONSTRUCTION MANAGER. 23. THE LATEST EDITION OF ALL PERMITTED AND APPROVED PLANS PERTAINING TO THIS PROJECT SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY WORKERS. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES. THESE ARE TO BE UNDER THE CARE OF THE CONSTRUCTION SUPERINTENDENT. 24. THE CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE MATERIALS ON A DAILY BASIS, EXCEPT FOR THAT SPECIFIED AS THE PROPERTY OF THE BUILDING OR PROPERTY OWNER AND SHALL EXERCISE STRICT CONTROL OVER SITE CLEANING THROUGHOUT CONSTRUCTION AND FINAL CLEAN-UP UPON COMPLETION OF WORK. ALL AREAS ARE TO BE LEFT IN A BROOM CLEAN CONDITION AT THE END OF EACH DAY THEN AT A VACUUM CLEAN CONDITION, FREE FROM PAINT SPOTS, DUST OR SMUDGES OF ANY NATURE AT COMPLETION OF WORK. 25. THE GENERAL CONTRACTOR MUST PERFORM WORK DURING PROPERTY OWNER'S PREFERRED HOURS TO AVOID DISRUPTION OF NORMAL ACTIVITY. 26. ALL EXPOSED METAL SHALL BE HOT -DIPPED GALVANIZED. 27. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF AND WHERE APPLICABLE TO THIS FACILITY AND PROJECT SITE. 28. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE PROJECT AREA UNDER CONSTRUCTION. 29. ELECTRICAL POWER SYSTEM SHALL BE GROUNDED PER NEC ARTICLES 250 AND 810. 30. ALL NEW OPENINGS IN THE EXTERIOR ENVELOPE OF CONDITIONED SPACES SUCH AS AT WALL AND ROOF PENETRATIONS SHALL BE CAULKED OR SEALED TO LIMIT INFILTRATION OF AIR AND MOISTURE. 31. UPON COMPLETION OF CONSTRUCTION, T-MOBILE CONSTRUCTION MANAGER SHALL CONDUCT A WALK-THRU WITH PROPERTY OWNER OR REPRESENTATIVE OF PROPERTY OWNER. 32. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL SYSTEM EQUIPMENT IN A CLEAN WORKING ORDER UNTIL ACCEPTANCE OF THE PROJECT BY T-MOBILE. 33. INSTALL ALL EQUIPMENT AND MATERIALS PER THE LATEST EDITION OF THE MANUFACTURER'S INSTALLATION SPECIFICATIONS UNLESS SPECIFICALLY OTHERWISE INDICATED, OR WHERE LOCAL CODES OR REGULATION TAKE PRECEDENCE. RESUBMITTED Mar 24 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT T Mobile 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 AMERICAN TOWER CORPORATION INFINIGY8 FROM ZERO TO INFINIGY the solutions are endless BELLEVUE, WA 98004 T-MOBILE SITE: SE04723A FEDERAL WAY DISTRIBUTION CENTERS ATC SITE: 91531 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 KING COUNTY 120'-0" MONOPOLE DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION OA/OC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD SHEET TITLE: SPECIFICATIONS & NOTES SHEET NUMBER: I REVO N: T-2 �2 PAINT SPECIFICATIONS 1 1 GENERAL SPECIFICATIONS I l THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. [e I i ) (0)) Radio frequency fields beyond this point may exceed the FCC general public exposure limit. Obey all posted signs and site guidelines for working in radio frequency environments. TMobile ° PART No. TMO142862 ® NOTICE ® ° GUIDELINES FOR WORKING IN RADIO FREQUENCY ENVIRONMENTS ® All personnel should have electromagnetic energy (EME) awareness training. ® All personnel entering this site must be authorized. ® Obey all posted signs. ® Assume all antennas are active. ® Before working on antennas, notify owners and disable appropriate transmitters. ® Maintain minimum 3 feet clearance from all antennas. ® Do not stop in front of antennas. ® Use personal RF monitors while working near antennas. ® Never operate transmitters without shields during normal operation. ® Do not operate base station antennas in equipment room. T Mobile PART No. TMO130956 °ACAUTION ° Beyond this point: Radio frequency fields at this site may exceed FCC rules for human exposure. For your safety, obey all posted signs and site guidelines for working in radio frequency environments. ,see" TMobile ° PART No. TMO 142851 m ARNING" Beyond this point: Radio frequency fields at this site exceed FCC rules for human exposure. Failure to obey all posted signs and site guidelines for working in radio frequency environments could result in serious injury. 3o;ipi, T. 0 PART No. TMO 145771 O O T Mobile IN CASE OF AN EMERGENCY CALL 1-888-662-4662 Site No: FEWWWAY Site Name: DISTRIBUTION O O T-0" A. GENERAL 1. PRECEDENCE: UNLESS OTHERWISE SHOWN OR SPECIFIED, THE FOLLOWING GENERAL NOTES SHALL APPLY. INFORMATION ON THESE DRAWINGS SHALL HAVE THE FOLLOWING PRECEDENCE. A. ALL DIMENSIONS TO TAKE PRECEDENCE OVER SCALE SHOWN ON PLANS, SECTIONS AND DETAILS. B. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. C. MATERIAL NOTES AND SPECIFICATIONS ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER THE SPECIFICATIONS. 2. OTHER TRADES: SEE THE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT SHOWN. 3. GENERAL DETAILS AND NOTES ON THESE SHEETS SHALL APPLY UNLESS SPECIFICALLY SHOWN OR NOTED OTHERWISE. CONSTRUCTION DETAILS NOT FULLY SHOWN OR NOTED SHALL BE SIMILAR TO DETAILS SHOWN FOR SIMILAR CONDITIONS. 4. SHORING: IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL ALL TEMPORARY BRACING AND SHORING TO INSURE THE SAFETY OF THE WORK UNTIL IT IS COMPLETED. THIS INCLUDES UNDERPINNING EXISTING FOOTINGS WHERE APPLICABLE. 5. SAFETY: THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. UNLESS OTHERWISE INDICATED, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. 6. WATERPROOFING: WATERPROOFING AND DRAINAGE DETAILS OR SPECIFICATIONS SHOWN IN THESE DRAWINGS ARE FOR GENERAL INFORMATIONAL PURPOSES ONLY. CONTRACTOR TO NOTIFY THE T-MOBILE CONSTRUCTION MANAGER AND THE ARCHITECT IF ANY INADEQUATE OR IMPROPER CONDITIONS. B. STEEL 1. ALL STRUCTURAL STEEL SECTIONS AND WELDED PLATE MEMBERS SHALL CONFORM TO ASTM A-36 AND BE FABRICATED IN ACCORDANCE WITH THE SPECIFICATIONS OF THE AISC. 2. ALL BOLTS SHALL CONFORM TO ASTM A-307 UNLESS OTHERWISE NOTED ON PLANS. HIGH STRENGTH BOLTS SHALL CONFORM TO ASTM A-325 3. STEEL PIPE COLUMNS SHALL BE GRADE "B" CONFORMING TO ASTM A53. 4. STEEL TUBING SHALL BE GRADE "B" CONFORMING TO ASTM A500. 5. ALL WELDING SHALL BE DONE BY THE SHIELDED ARC METHOD. ALL WELDERS SHALL BE PROPERLY QUALIFIED AND BE PRE -APPROVED. SURPLUS METAL SHALL BE DRESSED OFF TO SMOOTH, EVEN SURFACES WHERE WELDS ARE NOT EXPOSED TO VIEW. ALL WELDING SHALL COMPLY WITH THE LATEST A.W.S. SPECIFICATIONS. 6. THE FOLLOWING WELDING EQUIPMENT MUST BE USED: A. 250 AMP WELDERS. B. ROD OVENS. C. GRINDERS. 7. NO BUZZ BOXES SHALL BE USED. 8. ALL STRUCTURAL STEEL SHALL HAVE MILL CERTIFICATION. MILL CERTIFICATION SHALL BE KEPT ON THE JOB SITE FOR EXAMINATION BY THE DESIGN ENGINEER AND THE CITY INSPECTOR. 9. ALL HIGH STRENGTH BOLTS SHALL HAVE MILL CERTIFICATION. MILL CERTIFICATION SHALL BE KEPT ON THE JOB SITE FOR EXAMINATION BY THE INSPECTOR. 10. STEEL THAT HAD BEEN WELDED, CUT OR SCRATCHED IN THE FIELD SHALL BE TOUCHED UP WITH COLD GALVANIZING PAINT. 11. WELDING INDICATED IN THESE DRAWINGS IS DESIGNED FOR ONE HALF OF ALLOWABLE CODE STRESSES UNLESS NOTED "FULL STRESS" AT END OF WELD SYMBOL. C. CONCRETE 1. STRENGTH: CONCRETE FOR THE PROJECT SHALL HAVE THE FOLLOWING ULTIMATE COMPRESSIVE STRENGTH AT AGE OF 28 DAYS: LOCATION STRENGTH WT. SLUMP ADMIXTURE SLAB&FOOTING 3000psi 150pcf 4" NONE 2. INSPECTION: CONCRETE WITH SPECIFIED STRENGTH GREATER THAN 2500psi SHALL BE CONTINUOUSLY INSPECTED DURING PLACEMENT BY A DEPUTY INSPECTOR EMPLOYED BY A TESTING LABORATORY APPROVED BY THE BUILDING DEPT. 3. REBAR GRADES: REINFORCING STEEL SHALL BE CLEAN PREFORMED BARS CONFORMING TO ASTM A615 AS FOLLOWS: #4 & SMALLER BARS ................. GPADE 40 #5 & LARGER BARS...................GRADE 60 ALL BARS AT CAISSON FOOTING... GRADE 60 4. FOUNDATIONS & SLABS: TYPE V, LOW ALKALI, CONFORMING TO ASTM C-150. PIER/CAISSON FOOTINGS: TYPE V, LOW ALKALI, CONFORMING TO ASTM C-150. 5. AGGREGATE: USED IN THE CONCRETE SHALL CONFORM TO ASTM C-33. USE ONLY AGGREGATES KNOWN NOT TO CAUSE EXCESSIVE SHRINKAGE. THE MAXIMUM SIZE AGGREGATE IN CONCRETE WORK SHALL BE THE FOLLOWING: A. FOUNDATIONS & SLABS 9" OR LESS: 3/4" GRAVEL B. PIER/CAISSON FOOTING: 1" GRAVEL. 6. SHALL BE CLEAN AND FREE FROM DELETERIOUS AMOUNT OF ACIDS, ALKALIS, ORGANIC MATERIALS AND SHALL BE SUITABLE FOR HUMAN CONSUMPTION. 7. MIXING: PREPARATION OF CONCRETE SHALL CONFORM TO ASTM C-94. NO MORE THAN 90 MINUTES SHALL ELAPSE BETWEEN CONCRETE BATCHING AND CONCRETE PLACEMENT UNLESS APPROVED BY A TESTING AGENCY. 8. SEGREGATION OF AGGREGATES: CONCRETE SHALL NOT BE FLOPPED THROUGH REINFORCING STEEL (AS IN WALLS, COLUMNS, CAISSON, AND DROP CAPITALS) SO AS TO CAUSE SEGREGATION OF AGGREGATES. USE HOPPERS, CHUTES, TRUNKS OR PUMP HOSE SO THAT THE FREE UNCONFINED FALL OF CONCRETE SHALL NOT EXCEED 5 FT. 9. SPLICES OF REINFORCING STEEL SHALL BE LAPPED A MINIMUM OF 30 DIAMETERS AND SECURELY WIRED TOGETHER. SPLICES OF ADJACENT REINFORCING BARS SHALL BE STAGGERED WHEREVER POSSIBLE. 10. REAR CLEARANCE: MINIMUM COVERAGE FOR JOISTS, BEAMS, GIRDERS AND COLUMNS SHALL BE TO FACE OF STIRRUPS OR TIES. UNLESS OTHERWISE NOTED, CONCRETE COVERAGE FOR REINFORCING BARS TO FACE OF BAR SHALL BE AS FOLLOWS: A. CONCRETE IN CONTACT WITH EARTH, UNFORMED 3" B. CONCRETE IN CONTACT WITH EARTH, FORMED 2" C. WALL, EXTERIOR FACE 1-1/2" D. WALL, INTERIOR FACE 1" E. STRUCTURAL SLABS 3/4" F. JOISTS 3/4" G. BEAMS, GIRDERS & COLUMNS 1-1/2" 11. PENETRATIONS: NO SLEEVES OR CHASES SHALL BE PLACED IN BEAMS, SLABS, WALLS AND COLUMNS, EXCEPT THOSE SHOWN ON THE PLANS. CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR INSTALLATIONS OF ANY ADDITIONAL SLEEVES OR CHASES. ALL PLUMBING, ELECTRICAL AND MECHANICAL OPENINGS SHALL BE SLEEVES. CORING IS NOT ALLOWED UNLESS PRIOR APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 12. EMBEDDED ITEMS: CONDUIT PLACED IN A CONCRETE SLAB SHALL NOT HAVE AN OUTSIDE DIAMETER GREATER THAN 1/4 THE THICKNESS OF THE SLAB. CONDUIT SHALL NOT BE EMBBEDED IN A SLAB THAT IS LESS THAN 3-1/2" THICK, UNLESS SLAB IS LOCALLY THICKENED. MINIMUM CLEAR DISTANCE BETWEEN COUNDUITS SHALL BE SIX INCHES. 13. ANCHORING: ALL ANCHOR BOLTS, REINFORCING STEEL, DOWELS, INSERTS, ETC., SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE. NO REPOSITIONING DURING CONCRETE POUR IS ALLOWED. 14. SLABS SHALL BE SPRAYED WITH A CURING COMPOUND IMMEDIATELY AFTER FINISHING. CURING COMPOUNDS USED ON CONCRETE WHERE TILE OR FLOOR COVERING IS TO BE BONDED TO THE CONCRETE SURFACE SHALL BE APPROVED BY THE TILE OR FLOOR COVERING MANUFACTURER. KEEP SLAB WET FOR 7 DAY MINIMUM PERIOD. 15. CONSOLIDATION: ALL CONCRETE SHALL BE VIBRATED AS IT IS BEING PLACED WITH ELECTRICALLY OPERATED VIBRATING EQUIPMENT. D. TIMBER 1. ALL FRAMING LUMBER FOR 4X AND LARGER BEAMS SHALL BE NO. 1 GRADE DOUGLAS FIR., S45, UNLESS NOTED OTHERWISE. 2. ALL FRAMING LUMBER FOR 2X RAFTERS AND JOISTS SHALL BE NO.2 GRADE DOUGLAS FIR, S45, UNLESS NOTED OTHERWISE. 3. STRIPPING, BLOCKING, BACKING AND OTHER NON-STRUCTURAL LUMBER SHALL BE NO. 2 OR STD & BTR GRADE DOUGLAS FIR, S45. 2X4 STUD WALLS SHALL BE D.F. STANDARD & BTR. 4. ALL BEAMS, JOISTS AND RAFTERS SHALL BE INSTALLED WITH CROWN SIDE UP. 5. ROOF PLYWOOD SHALL MATCH EXISTING PLYWOOD SHEATHING WITH A SPAN INDEX RATIO 32/16. EDGE NAIL WITH8d AT 6" O.C. UNLESS NOTED OTHERWISE ON PLANS. FIELD NAIL WITH 8d AT 12" O.C. 6. PLYWOOD SHEETS SHALL BE LAID WITH THE FACE GRAIN PERPENDICULAR TO SUPPORTS AND WITH THE EDGES STAGGERED, UNLESS NOTED OTHERWISE ON THE PLANS. 7. PLYWOOD SHALL BE GRADE MARKED BY DFPA, TECO, OR PTL AND SHALL CONFORM TO PS 1-83. 8. THE MAXIMUM MOISTURE CONTENT OF ALL LUMBER SHALL NOT EXCEED 24% AT THE TIME OF INSTALLATION. 9. MINIMUM NAILING SHALL COMPLY WITH TABLE 23-1-q OF BUILDING CODE. ALL NAILS SHALL BE COMMON WIRE NAILS. 10. ALL BOLTS SHALL HAVE STANDARD CUT WASHERS UNDER HEADS AND/OR NUTS WHERE IN CONTACT WITH WOOD. 11. LAG BOLTS SHALL BE SCREWED INTO PLACE, NOT DRIVEN. LAG BOLTS SHALL BE INSTALLED IN PRE -DRILLED HOLES WITH A DIAMETER EQUAL TO 75 % DIAMETER OF BOLT. 12. CONNECTORS: ALL SHEET METAL FRAMING CONNECTORS SHOWN IN THE PLANS SHALL BE STRONG CONNECTORS AS MANUFACTURED BY THE SAMSON COMPANY. SUBSTITUTIONS MAY BE MADE WHEN APPROVED BY THE STRUCTURAL ENGINEER. 13. ALL LUMBER EXPOSED TO WEATHER OR IN CONTACT WITH MASONRY OR CONCRETE SHALL BE WOLMANIZED PRESSURE TREATED LUMBER OR A NATURALLY DECAY RESISTANT LUMBER SUCH AS REDWOOD OR CEDAR. 14. ALASKAN YELLOW CEDAR GLUE -LAMINATED BEAMS A. LUMBER SPECIES: ALASKAN YELLOW CEDAR (A.C.) CONFORMING TO 20E-V12 B. STRENGTH PROPERTIES: Fb BOTTOM FIBER BENDING STRESS 2000psi MIN. Fb TOP FIBER BENDING STRESS 1000psi MIN. Fv SHEAR STRESS 190psi MIN. Fc COMPRESSION STRESS PERPENDICULAR TO GRAIN 560psi MIN. C. MODULUS ELASTICITY 1400ksi MIN. D. CAMBER TO RADIUS OF 1600° U.O.N. E. ALL GLB'S SHALL BE FABRICATED WITH EXTERIOR GLUE. F. MANUFACTURE OF GLB'S SHRRALLFLCCIJCON��{{F��OppRMMTTTOFFTnnHE G. GLLU-LAM MATERIAL SHALL BE IM1! ACCOR NCE'WITH ANSI/AITC A190.1 AND ASTM D3737. Mar 24 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT T Mobile 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 111L AMERICAN TOWER CORPORATION INFINIGY8 FROM ZERO TO INFINIGY the solutions are endless BELLEVUE, WA 98004 T-MOBILE SITE: SE04723A FEDERAL WAY DISTRIBUTION CENTERS ATC SITE: 91531 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 KING COUNTY 120'-0" MONOPOLE DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION OA/OC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD SHEET TITLE: SPECIFICATIONS & NOTES SHEET NUMBER: - 3 I REVIOSION: ,.2 1 SIGNAGE SPECIFICATIONS 1 1 1 STRUCTURAL SPECIFICATIONS I l THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. 1 EXISTING TREES AREA LEGAL DESCRIPTION: \ \ \ 20-25-44; TR A OF SP 91-687; AUD # 9210290076 BK 8 PG 98; LYG IN SW1/4 OF NW1/4 APN:202104-9157 EXISTING \ \ TREES AREA EXISTING PROPERTY LINE, \� TYP. (APPROXIMATE) r EXISTING BUILDING (TYP.) R1u►if- IYI[it1.0 (iN'TI I I, I I I I I I II I I I I II I I I I w I Q I H I I I I \ SHEET TITLE: SUBMITTED OVERALL — — INFORMATION CONTAINED WITHIN DRAWINGS Mar 24 2021 SITE PLAN IS BASED ON PROVIDED INFORMATION AND IS NOT THE RESULT OF A FIELD SURVEY. CITY OF FEDERAL WAY SHEET NUMBER: COMMUNITY DEVELOPMENT 1 OVERALL SITE PLAN 11".17gr.ALE 1"-100� A-1 1 rxn^ Rr.AI Fr- _ qnm-n^ inn- src m 1nm T Mobile 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 AV AMERICAN TOWER CORPORATION INFINIGY& FROM ZERO TO INFINIGY the solutions are endless BELLEVUE, WA 98004 r T-MOBILE SITE: SE04723A FEDERAL WAY DISTRIBUTION CENTERS ATC SITE: 91531 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 KING COUNTY 120'-0" MONOPOLE DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION QA/QC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD REVISION: 0 THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD INFORMATION CONTAINED WITHIN DRAWINGS EXISTING EQUIPMENT IS BASED ON PROVIDED INFORMATION AND IS PAD BY OTHERS (TYP.) NOT THE RESULT OF A FIELD SURVEY. ° EXISTING SPRINT UTILITY H-FRAME T Mobile ° a TO BE REMOVED (TYP.) 19807 NORTH CREEK PKWY N EXISTING SPRINT y y y y BOTHELL, WA 98011 CABINET TO BE REMOVED 29'-0" ATC EXISTING SPRINT FENCED COMPOUND CABINET TO BE REMOVED 18'-0" EXISTING CONCRETE PAD TO BE REMOVED y AMERICAN TOWER ° y EXISTING EQUIPMENT CORPORATION u PAD BY OTHERS (TYP.) 4 � G 'd INFINIGY8 I O 4 ` °` ° y FROM ZERO TO INFINIGY M the solutions are endless • O I EXISTING ATC BELLEVUE, WA 98004 ° XFENCED COMPOUND T-MOBILE SITE: r 12'-0" j EXISTING 8'-0" ° PROPOSED T-MOBILE SE04723A OIL WIDE DOUBLE a SWING EQUIPMENTLEASE FEDERAL WAY DISTRIBUTION Q 0 ° ° AREA WITHIN EXISTING EXISTING OTHER CARRIER W CENTERS = O = \ ACCESS GATE ICE BRIDGE (TYP.) EXISTING SPRINT TELCO 4, o ¢ ATC COMPOUND 6„ 10001, CABINET TO BE REMOVED a z O / o ATC SITE: EXISTING SPRINT ICE w � � BRIDGE TO BE REMOVED I` EXISTING MONOPOLE 3 1 EXISTING ENLARGED EQUIPMENT PLAN 22"x34"SCALE: 1/2"=1'-0" O O O 11"x17" SCALE: 1/4" = 1'-0" 2' 1' 0' 2' O RF EQUIPMENT SCOPE OF WORK -SEE RFDS PROPOSED T-MOBILE • INSTALL (2) AMIA, (2) ASIB, (3) ABIA, (3) ABIC, (2) ASIK, (4) HPL3 SSC CABINET 2 O ABIL, (1) FSMF & (1) CSR IXRe ROUTER INSIDE PURCELL HPL3 600A DC PLANT CABINET PROPOSED T-MOBILE 2 1 O EXISTING EQUIPMENT LB3 BBU CABINET A-s A-6.2 EXISTING O PAD BY OTHERS (TYP.) Q 10'GRAVEL AREA Qo ° ° a PROPOSED -0"x6'-0" ICE CANOPY y 60 A-7 PROPOSED T-MOBILE \ d a 2 1 � a HPL3 EXPANSION CABINET A-6 A-6.1 91531 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 KING COUNTY 120'-0" MONOPOLE 6„ om EXISTING UTILITY H-FRAME BY OTHERS (TYP.) / J O �o N PROPOSED T-MOBILE ANTENNA p AREA (SEE SHEET A-4) . IIIIIIIIIIIIIIIlIIIIIIIIIl�IIIIII!!IlIIIIlIIIlIIlill 4 IY�IIIII---- v �nnnne ' III III�IIIIIIIIIIIIIIIIIIIII �u W -----1111111 nr..........n�llllr_nnnnn1eg1111 /11111111111111111111 � Illlllllllllllllillll -----1 IIIIIIIIIIIIIIYIIIII nnnnn nnnnn 11 !I liiin � •� iIIg11111� � as.��n.s�mi DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION OA/OC O 2=0"' 1'-1" 9" ° ° a � �r INGRESS _ PROPOSED w o T-MOBILE EXISTING EQUIPMENT 0 2�-6" 25kWUU SHELTER BY OTHERS (TYP.) EGRESS1111 _ f O o DIESEL z y ° GENERATOR o O (}7' CO)° W1211 GAL O ° SUBTANK V) O o o y d EXISTING ° As 3 a 2/11 21 MONOPOLE 0190 y � IST'k��� EXISTING OTHER s'VIQNAL�� CARRIER ICE ° ° BRIDGE (TYP.) ° y PROPOSED T-MO ILE 15'1 y y y y y A-7 ICE BRIDGE PROPOSED CONCRETE PAD y PROPOSED T-MOBILE UNISTRUT H-FRAME A-7 sHEErnrLe PROPOSED T-MOBILE A-7 GPS ANTENNA PROPOSED T-MOBILE200AACUBE MET OV RESUBMITTED PROPOSED T-MOBILE 200A AC METER I ENLARGED s PROPOSED 15'-0"x10 =0" �/ PROPOSED T-MOBILE PPC ON H-FRAME C OF FEDERAL WAv / SITE PLANS A-7 CONCRETEPAD COMMUNITY DEVELOPMENT Mar 24 2021 : yPROPOSED T-MOBILE HCS 2.0 COVP PROPOSED T-MOBILE LED z By: CSkaCxn CITY OF FEDERAL WAY SHEET NUMBERREVISION: A-s ON UNISTRUT H-FRAME (2 TOTAL) —1 / LIGHT WITH TIMER (1 TOTAL) A-7 oals/soil COMMUNITY DEVELOPMENT C ^ 0 2 PROPOSED ENLARGED EQUIPMENT PLAN 11"x17"SCALE: 1/4"=V-0" 2' 2' ENLARGED SITE PLAN 22"x34"SCALE: 3116-- ® 1 1"x17" SCALE: 3/16"=1'0" 2' 1' 0' 2' THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. T Mobile 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 AMERICAN TOWER TOP OF EXISTING MONOPOLE TOP OF EXISTING MONOPOLE CORPORATION ELEV. _ ±120'-0" REF., ±120'-6" AGL ELEV. _ ±120'-0" REF., ±120'-6" AGL h TOP OF EXISTING ANTENNAS BY OTHERS TOP OF EXISTING ANTENNAS BY OTHERS ELEV._ ±115'-0" REF., ±115'-6" AGL v ELEV. _ ±115'-0" REF., ±115'-6" AGL H e- INFINIGYS's FROM ZERO TO INFINIGY OF EXISTING ANTENNAS (BY OTHERS) EXISTING PANEL ANTENNAS ELEV. = ±112'-0" REF., ±112'-6" AGL BY OTHERS MOUNTED TO MONOPOLE, TYP. OF EXISTING ANTENNAS (BY OTHERS) EXISTING PANEL ANTENNAS ELEV. _ ±112'-0" REF., ±112'-6" AGL BY OTHERS MOUNTED TO MONOPOLE, TYP. the solutions are endless BELLEVUE, WA 98004 T-MOBILE SITE: ti OF EXISTING ANTENNAS (BY OTHERS) ELEV.=±95'-0"REF.,±95'-6"AGL 4 OF EXISTING ANTENNAS (BY OTHERS) ELEV.=±95'-0"REF.,±95'-6"AGL SE04723A FEDERAL WAY DISTRIBUTION TOP OF PROPOSED T-MOBILE ANTENNAS ELEV.=±87'-0" REF., ±87=6"AGL PROPOSED T-MOBILE ANTENNAS WITH ASSOCIATED EQUIPMENT MOUNTED TO MONOPOLE - SEE SHEET A-4 CENTERS ATC SITE: E OF EXISTING SPRINT ANTENNAS _ ELEV. _ ±g3'-0" REF., ±83'-6" AGL EXISTING SPRINT PANEL ANTENNAS TO BE REMOVED 4 OF PROPOSED T-MOBILE ANTENNAS ELEV. =±83 =0" REF., ±83 =6"AGL 91531 E OF EXISTING SPRINT DISH ANTENNA ELEF. V.=±79'-0" RE, ±79'-6" AGL EXISTING SPRINT DISHELEV.=±79'-0" ANTENNAS TO REMAIN OF EXISTING SPRINT DISH ANTENNA 4. F. RE, ±79'-6" AGL I EXISTING DISH ANTENNAS s 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 EXISTING ATC MONOPOLE EXISTING ATC MONOPOLE KING COUNTY NOTES: • THESE DRAWINGS ARE NOT INTENDED TO BE A VERIFICATION THAT THE STRUCTURE OR 120'-0" MONOPOLE MOUNTS ARE ADEQUATE TO SUPPORT THE PROPOSED LOADING. VERIFICATION THAT THE EXISTING STRUCTURE AND MOUNTS CAN PROPOSED T-MOBILE SUPPORT THE PROPOSED LOADING SHALL BE CABLING - SEE ANTENNA PERFORMED BY A REGISTERED PROFESSIONAL SCHEDULES ON SHEET A-4 ENGINEER PRIOR TO CONSTRUCTION. • CONTRACTOR TO REFER TO THE STRUCTURAL ANALYSIS AND MOUNT ASSESSMENT AND VERIFY LOADING WITH THE MOST RECENT RFDS PRIOR TO CONSTRUCTION. DRAWINGS ISSUED FOR: REV. DATE I DRAWN DESCRIPTION OA/OC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD ERfW pF �� 2/11 21 EXISTING SPRINT PROPOSED T-MOBILE EQUIPMENT AT = � �F40190 EQUIPMENTS TO BE REMOVED EXISTING CHAIN SEE SHEET A-2 EXISTING CHAIN 1 LINK FENCE - LINK FENCE srtoNAL BOTTOM OF TOWER STEEL BOTTOM OF TOWER STEEL SHEETTITLE: ELEV. = 0'-0" REF., 6" AGL ELEV. = 0'-0" REF., 6" AGL SOUTH GRADE GRADE ELEV. = 0'-0" AGL (±295' AMSL) APPROVED RESUBMITTED PLANNING ELEVATIONS ELEV. = 0'-0" AGL (±295' AMSL) CITY OF FEDERAL WAV Mar 24 2021 SHEET NUMBER: REVISION: COMMUNITY DEVELOPMENT By: CSCITY FEDERAL WAY Dan 5/2021 /2021 COMMUNITY DEVELOPMENT A — 3 H 0 2 EXISTING SOUTH ELEVATION PROPOSED SOUTH ELEVATION 22"xl7"SCALE: 1/8"=1'-0" 11"x17"SCALE: 1/16'-=100" 8' 6' 4' 2' 0' 8' 11"x7"SCALE: 1/16"=1'-0" 8' 6' 4' 2' 0' 8' THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. EXISTING ANTENNA / CABLE SCHEDULE MOUNT RFDS ANTENNA RRH TMA/COMBINER/COVP HYBRID CABLE (HCS) COAX CABLE SECTOR POSITION MODEL SIZE AZIMUTH RAD CENTER QTY. MODEL QTY. MODEL QTY. TYPE LENGTH QTY. TYPE LENGTH ALPHA Al ETCR-6541-121-16 84.9" 00 83'-0" 1,1 RRH-P4 (1.9 GHz), RRH-P4 3 ASU9325TYPOl ±150'-0" A2 -- -- 1 RRH-V3 A3 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- BETA B1 ETCR-654L12H6 84.9" 120' 83'-0" 1, 1 RRH-P4 (1.9 GHz), RRH-P4 B3 1 RRH-V3 GAMMA C1 ETCR-6541-121-16 84.9" 240° 83'-0" 1,1 RRH-P4 (1.9 GHz), RRH-P4 C2 1 RRH-V3 C3 MW MW1 PX2F-52 2.09' 0° 79'-0" 1 1 CAT-5 90'-0" MW MW1 PX2F-52 2.09' 120° 79'-0" 1 1 CAT-5 go, -0'. PROPOSED ANTENNA / CABLE SCHEDULE MOUNT RFDS ANTENNA RRH TMA/COMBINER/COVP HYBRID CABLE (HCS) COAX CABLE SECTOR POSITION MODEL SIZE AZIMUTH RAD CENTER QTY. MODEL QTY. MODEL QTY. TYPE LENGTH QTY. TYPE LENGTH ALPHA A2 AEHC 38.2" 40° 83.O" — 2 HCS 2.0 PENDANT 2 FD21206-48S55-XXX 3110'-0" Al FFW-65C-R3-V1 95.9" 40° 83=0" 1,1 AHLOA,AHFIG BETA B2 AEHC 38.2" 110° 83=0" B1 FFW-65C-R3-V1 95.9" 110° 83-0" 1,1 AHLOA,AHFIG GAMMA C2 AEHC 38.2" 250° 83=0" C1 FFW-65C-R3-VI 95.9" 250° 83N0" 1,1 AHLOA,AHFIG NOTES 1. CONTRACTOR IS TO REFER TO T-MOBILE'S MOST CURRENT RADIO FREQUENCY DATA SHEET (RFDS) PRIOR TO CONSTRUCTION. 2. CABLE LENGTH IS APPROXIMATE. CONTRACTOR TO FIELD VERIFY CABLE LENGTHS PRIOR TO ORDERING, FABRICATION, OR INSTALLATION OF CABLES. 3. PROPOSED EQUIPMENT IS INDICATED BY BOLD TEXT T Mobile 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 AMERICAN TOWER CORPORATION INFINIGYS' FROM ZERO TO INFINIGY the solutions are endless BELLEVUE, WA 98004 T-MOBILE SITE: SE04723A FEDERAL WAY DISTRIBUTION CENTERS ATC SITE: 91531 NOTE: MOUNT SECTORS ARE CLOCKWISE. MOUNT POSITIONS ARE CLOCKWISE (LEFT TO RIGHT AS VIEWED FROM THE BACK OF THE ANTENNAS, TO ALIGN WITH TOWER OWNER ANTENNA POSITION FORMAT), INCLUDING EMPTY ANTENNA MOUNT PIPES. RFDS POSITIONS ARE THE ANTENNA POSITIONS LISTED IN THE RFDS, AND MAY DIFFER FROM THE ORDER IN WHICH EXISTING ANTENNAS ARE INSTALLED. THE METHOD FOR WHAT ORDER ANTENNAS ARE LISTED IN THE RFDS VARIES DEPENDING ON THE MARKET. 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 1 CAT-5 90'-o" KING COUNTY MW MW1 PX2F-52 2.09' 120° 79'-0" 1 1 CAT-5 90'-0" 3 RF SCHEDULES NOTTO 3GALE 120'-0" MONOPOLE Q z P W �P5 LU z EXISTING SPRINT PANEL ANTENNA TO a A2 QP Al BE REMOVED (2 PER SECTOR, 6 TOTAL) PROPOSED T-MOBILE AHLOA EXISTING SPRINT RRH-P4 (1.9 GHz) TO EXISTING ATC MONOPOLE (1 PER SECTOR, 3 TOTAL) 00 EXISTING ATC MONOPOLE OTHER CARRIER ANTENNA COUNT ANTENNA RAD CENTER MODEL QTY. 115'-0" EPBQ-654L8H8-B 3 115'-0" DS7W2QT8-VT 3 115'-0" EPBQ-654L8H8-L2 3 112'-0" 78210406 6 112'-0" ALLGON LGP21403 6 95'-0" MX06FRO840-02 3 79'-0" 2' MICROWAVE PX2F-52 2 AT&T b 115 -0 RAD: 9 EXISTING ANTENNAS AT&T O 112'-0" RAD: (12) EXISTING ANTENNAS VERIZON 0 95'-0" RAD: 3 EXISTING ANTENNAS DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION OA/OC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD BE REMOVED (1 PER SECTOR, 3 TOTAL) a A-5 A-5 EXISTING SPRINT RRH-V3 (2.5 GHz) TO EXISTING SPRINT RRH-P4 TO BE BE REMOVED (1 PER SECTOR, 3 TOTAL) REMOVED (1 PER SECTOR, 3 TOTAL) PROPOSED T-MOBILE PANEL f jrr ANTENNA MOUNTED TO MONOPOLE B2 (1 PER SECTOR, 3 TOTAL) i3F 1 a C1 A-5 A-5 EXISTING SPRINT ANTENNA EXISTING SPRINT ANTENNA MOUNT TO REMAIN PROPOSED T-MOBILE AHFIG MOUNT TO REMAIN (1 PER SECTOR, 3 TOTAL) 2/11 {211� 40190 �P5°C A��FC A-s A-5 "Cr PA/v q� sTFGIST E�P���Z� g2N'FNryq 1 PPNE� Py,2y0° A2, jE0 4" " r�QNAL � PROPOSED T-MOBILE HCS 2.0 PENDANT (2 TOTAL) SHEET TITLE: N A5 C2 61 APPROVED RESUBMITTED ANTENNA PLANS PROPOSED T-MOBILE PANEL PLANNING & RF SCHEDULES I ANTENNA MOUNTED TO MONOPOLE cIMUNITY OERAL WAY DEVELOPMENT Mar 24 2021 (1 PER SECTOR, 3 TOTAL) COMMUOF FED VELOPMENT By: CSkad— CITY OF FEDERAL WAY SHEET NUMBER: REVISION: 1 2 04115/2021 COMMUNITY DEVELOPMENT A—4 0 2 EXISTING ANTENNA PLAN SOCALE 1 PROPOSED ANTENNA PLAN SOCALE THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. 2 1 NOT USED Configuration 56790EZ_SR_T * For 5G and LTE Airscale BB dimensioning refer to Fiber Part matrices. (Alpha, Beta & Gamma) FDD - Lowband LB+MS000 B12 (1-700) - 5 MHz Passive Antenna B71 (1-600) -10 MHz B71 (N600) - 10 MHz L19+ L21+AWS3 H AEHC LTE+5G = i B41 = Aicbwe Anrerm 8 7 6 5=4 3 2 1 Top Ground HC52.0 TowerTop 5G Airscale AHFIG AWS}PCS HCS2.0 ToIwerTop 1 1 PROPOSED RF PLUMBING DIAGRAM FDD - Midband 134 (L2100) - 20 MHz B66 (AWS3) - 5 M H z 132 (L1900) - 20 MHz B25 (L1900) - 20 MHz SRAN - GSM PCS TDD - Band 41 L2.5(2.5GHz)-60 MHz N41(2.5GHz) - 100MHz +2nd carrier (<=80MHz) SRAN LTE + GSM FSMF GSM PCs LTE FDD/TDD Airscale9 T Mobile 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 AV AMERICAN TOWER CORPORATION r T-MOBILE SITE: 1 SE04723A FEDERAL WAY DISTRIBUTION CENTERS ATC SITE: 91531 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 KING COUNTY 120'-0" MONOPOLE DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION QA/QC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD r r — 40190°` r sS�QNAL�� r e r , SHEET TITLE: RESUBMITTED RF PLUMBING Mar 24 2021 DIAGRAM r CITY OF FEDERAL WAY SHEET NUMBER: REVISION: COMMUNITY DEVELOPMENT A-4.1 0 HIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. O O AHFIGHEIGHT: RADIO MODULE HEIGHT: RADIO MODULE T Mobile HEIGHT: 27.56" HEIGHT: 22.05" O MOUNTING TO PIPE MOUNT WIDTH: 13.39" WIDTH: 12.13" DEPTH: 5.59" DEPTH: 7.44" 19807 NORTH CREEK PKWY N LU-- O WEIGHT: 79.4 LBS WEIGHT: 83.8 LBS BOTHELL, WA 98011 PENDANT INCLUDES A GROUNDING STUD. 13.39" 5.59" 12.13" 7.44" n ® A 2-6 AWG WEUN ASATHETRAIBLE CONDUCTOR SHOULD BE RUN AS STRAIGHT AND SHORT AS POSSIBLE TO AN ADEQUATE FRONT GROUNDING POINT TO PERFORM AMERICAN TOWER PROPERLY. (CONTRACTOR SUPPLIED) CORPORATION MANUFACTURER:COMMSCOPE MODEL: FD21206-48S55-XXX o 0 WEIGHT: o LB/FT 0 NN DIMENSIONS: 1.55"0 n U MOUNTG KIT: c-4 INFINIGY8 BOTTOM RIGHT MOUNTKT PROVIDED FROM ZERO TO INFINIGY NOTE: L the solutions are endless PENDANT MOUNTING ON UNISTRUT PER d MANUFACTURER'S SPECIFICATIONS FRONT SIDE BELLEVUE, WA 98004 ADDITIONAL HOSE CLAMP TORQUE VALUE RANGE: FRONT SIDE T-MOBILE SITE: (IF REQUIRED) 6 +/5NM (53+/-41N LBS) SE04723A 13.39" 12.13"' FEDERAL WAY DISTRIBUTION P..GLE CENTERS ' ATC SITE: 91531 HARDWARE INSERT ADAPTER TOP TOP 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 6 HYBRID W/ PENDANT DETAIL NOT 5 AHFIG DETAIL NOT TO 4 AHLOA DETAIL NT KING COUNTY SCALE SCALE SCACALE MECHANICAL MANUFACTURER: COMMSCOPE DOWNTILT MANUFACTURER: NOKIA MODEL: FFVV-65C-R3-V1 25.2 BRACKET 9'3 MODEL: AEHC 120'-0" MONOPOLE WEIGHT: 124.6 LBS; BRACKETS: 14.6 LBS WEIGHT: 108 LBS DIMENSIONS: 95.9" X 25.2" X 9.3" DIMENSIONS: 38.2" X 21.4" X 8.1" FREQUENCY: REFER TO RF DATA SHEET FREQUENCY: REFER TO RF DATA SHEET DOWNTILT ANTENNA MOUNTING 25 2" BRACKET AND HARDWARE BY ANTENNA MANUFACTURER 21.4 T-MOBILE RADIO ® MOUNTED TO PIPE MOUNT 0 � WITH MANUFACTURER , SUPPLIED HARDWARE °D 21.4 DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION OA/OC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD TOP TOP MOUNT PIPE f 25.2" ® °n0 T-MOBILE ANTENNA rn N W V `o � �, o CO STAND OFF ARM — ..L�� OR PLATFORM 2/11 21 40190 ==p_ ANTENNA MOUNTINGS'S+ IST kIL �CS` IO BOTTOM KIT BY ANTENNA N AL FRONT SIDE MANUFACTURER RF CONNECTOR, TYP SHEET TITLE: EQUIPMENT RESUBMITTED DETAILS JUMPER CABLEMBr 24 2021 RF CONNECTOR, TYP __________ 7� SHEET NUMBER: REVISION: FRONT SIDE NOTE: ROTATE FRAME OF MOUNT TO MATCH DEGREE LINE WHERE CITY OF FEDERAL WAYw APPLICABLE. DEVELOPMENTCOMMUNITY H — 5 0 3 ANTENNA DETAIL NOTTO 2 ANTENNA DETAIL NOT TO MOUNTING DETAIL NOT TO SCALE SCALE SCALE THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. MANUFACTURER: NOKIA MANUFACTURER: NOKIA MANUFACTURER: NOKIA MODEL: FSMF (MODULE) DIMENSIONS:5.2"x17.6"x16.5" MODEL: ABIC UNIT DIMENSIONS:8.6"x14.2"x1.7" MODEL: ABIL UNIT DIMENSIONS:8.6"x14.2"x1.1" WEIGHT: 25.3 LBS WEIGHT: 5.8 LBS WEIGHT: 4.4 LBS T Mobile 19807 NORTH CREEK PKWY N SFP28 BOTHELL, WA 98011 RF2 RF4 RF6 RF8 S-RF1 S-RF2 o00000 00o p ®mm®m®mm®mm®mm®m t j I OQ000000080000000i O _ 0 C= S-RF1 S-RF2 0 ® AMERICAN TOWER QSFP28 CORPORATION RF1 RF3 RF5 RF7 RF9 INFINIGY8 FROM ZERO TO INFINIGY 11 FSMF DETAIL NOT TO SCALE 10 ABIC DETAIL NOT TO SCALE 9 ABIL DETAIL NOT TO SCALE MANUFACTURER: NOKIA MANUFACTURER: NOKIA MANUFACTURER: NOKIA the solutions are endless MODEL: AMIA UNIT MODEL: ASIB UNIT MODEL: ASIK UNIT DIMENSIONS:5.1"x15.7"x17.6" a DIMENSIONS:8.6"x14.2"x1.7" DIMENSIONS:8.6"x14.2"x1.7" BELLEVUE, WA98004 WEIGHT: 11.2 LBS (UNIT ONLY) e WEIGHT: 6.4 LBS WEIGHT: 6.6 LBS e e SYNC IN SYNC OUT EIF3 T-MOBILE SITE: ° DC IN EAC SEI1 SEI2 EIF2 EIF5 SE04723A -- Q 0 O o0mo®momo ° FEDERAL WAY DISTRIBUTION °°°° ° o°oe 00 00.000000 O ® o0 000000000 0 Oo° ® _000000 0 �o, O -, O o� a a a oommoom m CENTERS ® °o°,°°eo,°o° aaa o 0° ® eeegee ®® ®®® 000000 00 o ATC SITE: o SRIO EIF1 LIMP LMP 91531 e o° °°°o°,°oa° FAN STATUS SEI EIF1 EIF2 EIF4 34301 9TH AVENUE SOUTH a FEDERAL WAY, WA 98003 COUNTY 8 AMIA DETAIL NOT'T 7 ASIB DETAIL NO 6 gSIK DETAIL NOTTOKING SCALE SCALAl E SCALE 120'-0" MONOPOLE MANUFACTURER: ERICSSON MANUFACTURER: NOKIA 14' MODEL: PSU 4813 MODEL: ABIA UNIT FRONT OF JUNCTION BOX MANUFACTURER: RAYCAP MODEL RTMDC-5634-PF-48 DIMENSIONS: 1.7"x19.0"x14.3" DIMENSIONS: 8.6"x14.2"x1.1" ALARM SHOWN W/O ACCESS PANEL WEIGHT: 17.2 LBS WEIGHT: 4.6 LBS CONNECTIONS DIMENSIONS: 14.0"x8.0"x16.0" ALPHA LABEL---_� WEIGHT: 15.2 LBS MOUNTING BRACKET FUSE CONNECTORS o FIBER MANAGEMENT ® z BETA LABEL ----POWER INDICATION RF1 RF2 RF3 RF4 RF5 RF6 LED'S (1 PER SECTOR) 000000 0000 0 00000 00000 00000 00000 0 io }Oo• 00 00 _ o0 00 _ oo �. O { GAMMA LABEL ftw� 0000 °o°o °o°o o°o o°o o° FIBERADAPTERS, OVP'S (TYP. OF (1) ® QUANTITY 24, 3x8 CLIPS FACING FORWARD DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION OA/OC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD Ej FOR EACH SECTOR, (3) SECTORS TOTAL) DC POWER OUTPUTS L DC INPUT EXTERNAL POWER LUGS, QTY. 6 EACH, 2-14 AWG TERMINALS ALARM PORT SWITCHES f ALARM ENTRY GLANDS NOT 5 VOLTAGE BOOSTER DETAIL 4 ABIA DETAIL (QTY.1,o.2"-0.4") �F A� S°A ° SALTO E 7TRUNK 1/2" 0SIMPSON STRONG -TIE EQUIPMENT CABINET STRONG -BOLT 2 STAINLESS CONDUIT FITTING CABLE ENTRY — MANUFACTURER: NOKIA LOCK WASHER STEEL WEDGE ANCHOR WITH (QTY. 1, 1.5") GLAND (QTY. 2, 1.1"-1.7") MODEL: IXR-e 3-3/4" NOMINAL EMBEDMENT 2/11 21 DIMENSIONS: 17.25"x10.0"x1.75" WEIGHT: TBD FLAT WASHER (ICC ESR-3037), TO BE INSTALLED I EACH CORNER 14 +d 19 CONCRETE OF CABINET 4 TOTAL WITH ( GROUND LEVEL JUNCTION BOX FQ �yt sr�oNAL� SLAB PER PLAN MINIMUM 6.5" EDGE DISTANCE ALARM ENTRY GLANDS BOTTOM PANEL CONFIGURATION (QTY. 1, 0.2"-0.4") a BREATHER VENT---.- - W a d a 4 ALARM ENTRY GLANDS 00 e-SHEETTITLE: Z w 4 (QTY.1,0.2%0.4") FIBER JUMPER ENTRY GLANDW t-TTFrD EQUIPMENT m a M LU a DETAILS a Mar 24 2021 CONDUIT FITTING TRUNK CABLE ENTRY SHEET NUMBER: REVISION: a GLAND QTY. 2, 1.1 "-1.7" CITY OF FEDERAL WAY (QTY. 1, 1.5") ) COMMUNITY DEVELOPMENT G A—G V 0 L-L—) 3 ROUTER DETAIL NOT TO.CALF 2 CABINET ATTACHMENT DETAIL NOT TO 1 HCS 2.0 JUNCTION BOX DETAIL NOT TO SCALE SCALE SCALE THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. MANUFACTURER: PURCELL SYSTEMS INC MODEL: HPL3 600A DC CABINET WEIGHT: 430 LBS (WITHOUT EQUIPMENT) DIMENSIONS: 30.0"x48.0"x72.0" NOTE: • ADDITIONAL KNOCKOUTS MAY BE REQUIRED AND CAN BE DRILLED ON SITE AS NECESSARY. FOR CABINETS STARTING AT 501 THERE WILL BE A TOTAL OF (8) KNOCKOUTS (2) HORIZONTAL ROWS OF (4) RACK ASSIGNMENT RACK RU SLOT DESCRIPTION 15 14 3RD AIRSCALE 13 12 FIBER MUX 11 10 9 2ND a AIRSCALE O 8 7 FIBER MUX 6 5 4 1ST AIRSCALE 3 2 FIBER MUX 1 2 r O m RECTIFIER SHELF AAV CSR 4TH AIRSCALE FIBER MUX 3RDLEGACY BBU 2NDLEGACY BBU 1STLEGACY BBU 0 N r ISO VIEW FRONT VIEW FIBER ROLF 1: IT IS STIR RECOMMEP USE THESE KNOCKOUT FROM COVI WATER-TIG GROMMET (4) 7/8" 0 HOLES FOR HPL3 AND EXPANSION CABINET 2-STRING BATTERY RACK MOUNTING POINTS (4) 7/8"0 HOLES FOR HPL3 4-STRING BATTERY RACK MOUNTING POINT - SHIPPING HOOKS TO BE REMOVED AFTER CABINET INSTALL CORRECT KNOCKOUT TOOL REQUIRED FOR PUNCHING KNOCKOUTS. DO NOT DRILL KNOCKOUTSTHROUGH SKU# 34038 PURCELL 2" PLINTH (OPTIONAL) 29.6" (4) 3/4"0 HOLES FOR HPL3, AND EXPANSION CABINET CORNER MOUNTING POINTS 2„ o O o N O 0 O SKU# 34038 PURCELL 2" PLINTH SKU# 34038 PURCELL PLAN VIEW 2" PLINTH SIDE VIEW 4R. n" RIGHT VIEW 4nn- (6) KNOCKOUTS LOCATED INCONVENIENTLY FROM INTERNAL AIRSCALE EQUIPMENT & ARE NOT FEASIBLE. SEE FIBER ROUTE OPTION 1. KNOCKOUTFOR ETHERNET FOR ALARMS KNOCKOUTSFOR BATTERY WIRES (4) 5/8" 0 FOR -RY M( 3 FOR (RAGE O O O O O O O Q BACK VIEW 28.0" MOUNTING FOOTPRINT 1Q�^fin■ ■ '' ^�..■ ■ 1■� i� 1 $ it — ®t■l I INTERNAL ROUTING AIRSCALE BASEBAND ALPHA POWEI (48 BREAKER CSR ROUTER FIBER ROUTE OPTION 2: REAR KNOCKOUTS CAN BE UTILIZED FOR BOTTOM FIBER ROUTING FROM COVP TO AIRSCALE IF OPTION 1 IS UNAVAILABLE. 2 ROWS OF (4) 2" KNOCKOUTS INTENDED FOR POWER, TELCO, & BOTTOM FIBERS TO COVP. ALL INCOMING CABLING TO BE IN RIGID OR FLEXIBLE CONDUIT WITH AN LB. ANY OF THE BOTTOM KNOCKOUTS CAN BE USED FOR THE AC ALL DC POWER CABLES (BLUE) TO BE ROUTED AT THE LEFT SIDE OF THE CABINET FIBER KNOCKOUT FIBER CABLES (YELLOW) 19" RACK ADAPTER ALL FIBER CABLES (YELLOW) TO BE ROUTED AT THE RIGHT SIDE OF THE CABINET FIBER MUX/ DEMUX RECTIFIERS (10 POSITIONS) AIRSCALE BASEBAND EGACY ASEBAND FRONT VIEW RESUBMITTED (OPEN) Mar 24 2021 T Mobile 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 111L AMERICAN TOWER CORPORATION INFINIGYS' FROM ZERO TO INFINIGY the solutions are endless BELLEVUE, WA 98004 r T—MOBILE SITE: SE04723A FEDERAL WAY DISTRIBUTION CENTERS ATC SITE: 91531 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 KING COUNTY 120'-0" MONOPOLE DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION OA/OC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD I I I I I j c EQUIPMENT DETAILS POWER FEED SHEET NUMBER: REVISION: CITY OF FEDERAL WAY //^.�� COMMUNITY DEVELOPMENT A — I ' . 0 1 PURCELL HPL3 POWER CABINET DETAILS NOT TO SCALE THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD MANUFACTURER: PURCELL SYSTEMS INC MODEL: HPL3 LARGE BATTERY CABINET WEIGHT: 350 LBS (WITHOUT EQUIPMENT) DIMENSIONS: 30.0"x31.6"x60.4" NOTE: • WIRES RUN THROUGH PROVIDED KNOCKOUT. FOLLOW PROPER INSTALLATION OF GASKET BEFORE MATING THE 2 CABINETS 4X .875 0 HOLES FOR HPL3 AND EXPANSION CABINET 2-STRING BATTERY RACK MOUNTING POINTS 4X .875 0 HOLES F( HPL3 4-STRING BAl RACK MOUNTING P 4X .75 0 HOLES FOR HPL3 AND EXPANSION CABINET CORNER MOUNTING POINTS SKU# 34038 PURCELL 2" PLINTH SKU# 34038 PURCELL 2" PLINTH PLAN VIEW SIDE VIEW Q W t - a � 00 00 FRONT VIEW l'-, KNOCKO ETHERNE ALARMS KNOCKOU BATTERYI ISO VIEW LEFT VIEW SHIPPING HOOKS TO BE REMOVED AFTER CABINET INSTALL :ORRECT KNOCKOUT -OOL REQUIRED FOR 'UNCHING KNOCKOUTS. )O NOT DRILL :NOCKOUTSTHROUGH _.. .. 34038 PURCELL 2" PLINTH (OPTIONAL) MOUNTING FOOTPRINT BATTERY BRACKETS BATTERY VIBRATION MOUNTS — 30.3" FRONT VIEW (OPEN) )R ICHORAGE 4X BATTERY SHELVES,UP TO 200AH RESUBMITTED Mar 24 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT T Mobile 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 111L AMERICAN TOWER CORPORATION T-MOBILE SITE: SE04723A FEDERAL WAY DISTRIBUTION CENTERS ATC SITE: 91531 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 KING COUNTY 120'-0" MONOPOLE DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION QA/QC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD 4_j EFT TITLE: EQUIPMENT DETAILS SHEET NUMBER.— 6 ■ 2 I RE IN 1 PURCELL HPL3 BATTERY CABINET DETAILS NOl SCALE THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. SITE PRO 1 24" SUPPORT ARM OR PER PLAN APPROVED EQUAL NOTES: SITE PRO 1 24" WIDE GRIP 1. CONCRETE SHALL ATTAIN T Mobile STRUT ICE BRIDGE, OR COMPRESSIVE APPROVED EQUAL (CUT TO S STRENGTH OF fc=3,000 19807 NORTH CREEK PKWY N SUIT), TOUCH UP WITH 2 ° ° ° ° PSI MINIMUM AT 28 DAYS. BOTHELL, WA 98011 COATS OF GALVACON ` v v i' UL P v_ _I_ _ _ _ v _o _ _ _I 2, ALL REINFORCING STEEL Of LU COAX CABLE HANGERS ° e ° o SHALL COMPLY WITH > (TO SUIT CABLE SIZE) OR APPROVED EQUAL e o ASTM A615, GRADE 40. B LU f v l ( m Z - rt -g - - -' - - - - - - - - - - - - AMERICAN TOWER 24" WIDE SITE PRO 1 DIRECT -BURIAL 0- — �� �� — ` CORPORATION GRIPSTRUT PIPE COLUMN OR APPROVED EQUAL o_ LU I b 'b ° I I°'v v 1° v 1 J ' I CHANNEL z 3/4" CHAMFER BOTTOM OF COAX BLOCKING AT 8'-0' AGL V TOP OF EXISTING GRADE o o v v 6" PSI CONCRETE vl ° °_L_ SLAB ABW/#4REBAREACH INFINIGY8 / b ' ° o ' ° WAY @ 12" O/C f GALVINIZED STEEL POST p o FROM ZERO TO INFINIGY the solutions are endless CONCRETE PIER ��� �i p ��\��\� CONCRETE PIER 2500 ( PLAN VIEW BELLEVUE, WA98004 PSI-5 1/2 SACK MIX) SLOPE TO DRAIIy_ T-MOBILE SITE: zo z [� #q REBAR EACH 1/8" PER 12" WAY @ 12" O/C SE04723A '�--� — ° '--—-----` FEDERAL WAY DISTRIBUTION 1 ,17 �/ �/ / lI CENTERS a U SITE PRO 1 PART # 00 o v \\�%\ � ° p ° \�\ \ SCARIFY AND RECOMPACT THE UPPER 6" TO / ° g^ WIDE X 12" DEEP ATC SITE: Z o n DIRECT -BURIAL PIPE COLUMNS /� 90% RELATIVE COMPACTION PER ASTM D 1557\ UNLESS OTHERWISE AS NOTED IN FOOTING W/ (2) #4 91531 ° 13'-4" COLUMN 1B24D-V g„ \�/\� REBAR @ BOTTOM 18'-0" COLUMN 1B24D-216V GEOTECHNICAL REPORT 1'-6" 6MIL POLY VAPOR BARRIER ON SOIL 34301 9TH AVENUE SOUTH SECTION B-B FEDERAL WAY, WA 98003 KING COUNTY 6 ICE BRIDGE SPECIFICATION SOTTO rJ CONCRETE PAD DETAIL SOTTO SCALE SCALE CONNECT GRIP -STRUT PANELS TO LEDGER (MIN. 2 J.B. @ EA EN 120'-0" MONOPOLE 10'-10" Q 3/8x2"x0'-2" 4'-0" MAX. TO EACH POST CONTRACTOR TO VERIFY ABOVE SLAB OVERALL LENGTH REQUIRED 1-1/2" GALV. SQUARE P1000 10'-6" TO ACCOMMODATE EQUIPMENT UNISTRUT RAIL (12 GA.) ABOVE SLAB GRIP -STRUT PANELS (TYP.) COORDINATE EXACT PIPE CAP - LOCATION IN FIELD NOTE: 3-1/2" POST CAP LED LIGHT PLAN VIEW CONTRACTOR MAY NEED TO FIELD MODIFY LENGTHS 1/2" U-BOLT, TYP. MOGUL SOCKET MOUNTING 3" DIA. SCH 40 OF SOME CANOPY STAINLESS STEEL OR MEMBERS TO MEET L 4x4x1/4 CONTINUOUS MANUFACTURER'S CABLE OR GALV. PIPE (TYP) MINIMUM BASEPLATE LEDGER OTHER CABLE SUITABLE FOR ANCHORAGE EDGE EXTENDED SUNLIGHT EXPOSURE 1/2" U-BOLT (TYP.) DISTANCES ON SOME - CONCRETE SURFACES. 3"0 STD. (3.5" O.D.) PIPE METALLIC CABLE > II II DRAWINGS ISSUED FOR: REV. DATE I DRAWN DESCRIPTION OA/QC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD 318" WEEP HOLE @ 2 SIDES TERMINATION FITTING FYGA/FYGB MOUNTED ON A POLE g" NEAR BASE USING GPS MOUNTING KIT (FYMA)ISYSTEM) MIN. ICE CANOPY POST IL I 5/16 (4) HILTI KB-TZ 5/8"0 ANCHORS j END CAP (TYP) (3-1/8" EFFECTIVE EMBEDMENT) ER f W o a 11 a WEATHERPROOF 60 MIN. 0 8"x8"x1/2" STEEL �F A MODEL: FYGA/FYGB d a ROTARY TIMER LIGHT SWITCH I I I I BASEPLATE (TYP.) DEPTH: 3.74" a d WITH (4) 1/2" DIA. BOLTS WITH EPDXY I _ HEIGHT: 2.85" ° d * ANCHOR AND 4" 1 WEIGHT: 5.4 oz III ° a 3/4" RGS CONDUIT FOR (3) MIN. EMBEDMENT OPERATING TEMP: -40°F TO 185°F #12 AWG ELECTRICAL RUN 2/> > 21 FINISH GRA E 40190 �jp• - a d #2 AWG BARE SOLID TINNED a �C'is NOKIA BASE STATION: ° a a COPPER WIRE TO GROUND RING S t GPS GLONASS RECEIVER ANTENNA (FYGA/FYGB) OELEVATION S�ONAL� EXOTHERMIC WELD FLEXI MULTIRADIO BTS USES GPS (GLOBAL POSITICONCRETE SLAB PER PLAN 1-1/2" 1 OR GNSS (GLOBAL NAVIGATION SATELLITE SYSTEM8"x8"x1/2" STEEL FOR FREQUENCY AND TIME SYNCHRONIZATION. A BASEPLATE ANTENNA WITH AN INTEGRATED RECEIVER IS INST1"x12"x12" BASE PLATE FOR SATELLITE VISIBILITY, AND IS DIRECTLY CONNECTED TO THE TO PPC CABINET SHEET TITLE: TYP. SYSTEM MODULE. DC POWER FEED FOR THE RECEIVER IS SUPPLIED o � (4) HILTI KB-TZ 5/8"0 ANCHORS 3/16„ EQUIPMENT � \ THROUGH THE COMBINED POWER AND DATA CABLE. THE OPERATING (3-1/8" EFFECTIVE EMBEDMENT) UBMITTED TEMPERATURE RANGE ID FROM -40C TO +85C (-40F TO +185F). v a \RE 3" DIA. SCH 40 STAINLESS N DETAILS NOTE: FYGA/FYGB IS SET TO SUPPORT BOTH GPS AND GLONASS 3"0 STD. (3.5" OD.) PIPE STEEL OR GALV. PIPE (TYP SATELLITE SYSTEMS. TO SUPPORT GLONASS ONLY MODE, Mar 2¢ 2021 ) o 0 FYGA/FYGB HAS TO OPERATE WITH NOKIA APPROVED FIRMWARE O O t END VIEW SHEET NUMBER: REVISION: V2.11 OR LATER. CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT 7 0 4 GPS ANTENNA DETAIL NOT SCALE TO 3 ICE CANOPY DETAIL SOTTO 2 WORK LIGHT WITH TIMER DETAIL SCALE 1 H-FRAME DETAIL NOT SCALE SCALE THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. RD025 I 2AL 1 25 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency APPLICATION AND ENGINEERING DATA ENGINE SPECIFICATIONS General Make Generac EPA Emission Compliance Tier 4 Interim Cylinder W 4 Type In -Line Displacemeal • ins (L) 150 (2.46) Bore - In (mm) 3.3 (84.0) Stroke - in (mm) 3.9 (t 0o.o) Compression Ratio 21.3:1 Intake Air Method Naturally Aspirated Piston Type Aluminum Crankshaft Type Forged Steel Engine Block Type Gast Iron Engine Governing Governor Electronic Frequency Regulation (Steady State) ±025% Lubrication System Oil Pump Type Gear Oil Filter Type Full Flow Cartrtdge Crankcase Capacity with Fitters- qt (L) 6.87 (6.5) ALTERNATOR SPECIFICATIONS Standard Model GeneraC _ Pales 4 Field Type Rotating Insulation Class - Rotor H Insulation Class - stator H Total Harmonic Distortion <5% Telephone Interference Factor MF) <50 GENERAL' Cooling System Cooling System Type Closed Recovery Fan Type Pusher Fan Speed. rpm 1.800 Fan Diameler - in (mm) 18.11 (460) Fuel System INDUSTRIAL Fuel Type Ultra Law Sulfur Diesel Fuel Fuel Specillcallon ASTM Fuel Pump Type Mechanical Engine Driven Gear tniector Type Mechanical Fuel Supply Or (min) 7.9410.31 (0) Fuel Return Line (mrryln) 4.761.19110) Fuel Flliaring (mlcror}s) 25 Engine Electrical System System Voltage 12 VOC Battery Charger A1lemalcr Standard Battery $12e Group 27F Battery Voltage 12 VDC Ground Polarity Negalive Standard Excitation Direct Bearings Single Sealed Coupling Flexible Disc Prototype Short Circult Test Yes 011age Regulator Type Full Digital Number M Sensed Phases 2 Regulation Accuracy (Steady $late) ±1.0% RD025 I 2AL 1 25 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency DIMENSIONS AND WEIGHTS* I. W. j ENC LOUSED UNIT with 48hour Tank GENERAC INDUSTRIAL L x W x H in (mm) 95.4 (2,422) x 35.0 (880) x 73.2 (1,858) Sound output in dB(A) at 23ft with 65 generator operating at normal Load w All measuraroards are approximate and for estimation purposes only. spoClMatim riWazrpdS®t5 may &--Qt-hh" rlortb. Dtren -i a.0 wpghlS 0. for Pin' porpoW 0*. PLam [a1SM11 3 nw&g Power Sy5l Ir-JPvjW Peals fro de led'-5 bwn drawing5. Gomfoo Power Systems, Inc. I P.0.8ax 8 1 Waukesha, W153189 P' (262) 544.4811 W20180enerac Power Systems, Inc- AN nglne reserved- All specincallens are subject to change wltndal notice - Part No IODODMO90 Rev. A 0,1105/16 T Mobile 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 111L AMERICAN TOWER CORPORATION INFINIGY8 FROM ZERO TO INFINIGY the solutions are endless BELLEVUE, WA 98004 T-MOBILE SITE: SE04723A FEDERAL WAY DISTRIBUTION CENTERS ATC SITE: 91531 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 KING COUNTY 120'-0" MONOPOLE DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION QA/QC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD FOR REFERENCE ONLY TITLE: RESUBMITTED I I GENERATOR DETAILS Mar 24 2021 SHEETNUMBER: CITY OF FEDERAL WAY w COMMUNITY DEVELOPMENT /` — A 1 GENERATOR DETAIL NOT H j�i( SCALE THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. REVISION: 0 PANEL ID: A BUS: 200A PANEL MAIN: 200A BREAKER LOCATION: ONH-FRAME LTAGE: 120/240V SCHEDULE PHOASE/WIRE: 10/3WIRE FED FROM: SERVICE DISCONNECT SINGLE PHASE AIC: SPECIALS: P# CIRCUIT DESCRIPTION AMPS/ POLES O AMPS/ POLES CIRCUIT DESCRIPTION P# 1 PURCELL HPL3 POWER CABINET 200A 2p A 20 1 p LIGHT 2 3 -- B 20 lP GFCI 4 5 SPACE A SPACE 6 7 SPACE B SPACE 8 9 SPACE A SPACE 10 11 SPACE B SPACE 12 13 SPACE A SPACE 14 15 SPACE B SPACE 16 17 SPACE A SPACE 18 19 SPACE B SPACE 20 21 SPACE A SPACE 22 23 SPACE B SPACE 24 25 SPACE A SPACE 26 27 SPACE B SPACE 28 29 SPACE A SPACE 30 1. UTILITY POINTS OF SERVICE AND WORK / MATERIALS SHOWN ARE BASED UPON PRELIMINARY INFORMATION PROVIDED BY THE UTILITY COMPANIES AND ARE FOR BID PURPOSES ONLY. 2. CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY FOR FINAL AND EXACT WORK / MATERIALS REQUIREMENTS AND CONSTRUCT TO UTILITY COMPANY ENGINEERING PLANS AND SPECIFICATIONS ONLY. CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUIT, PULL ROPES, CABLES, PULL BOXES, CONCRETE ENCASEMENT OF CONDUIT (IF REQUIRED), TRANSFORMER PAD, BARRIERS, POLE RISERS, TRENCHING, BACKFILL, PAY ALL UTILITY COMPANY FEES AND INCLUDE ALL REQUIREMENTS IN SCOPE OF WORK. 1 3 1 PANEL SCHEDULE s�Q� (3) #3 THWN W/ 1 1/2" CONDUIT AUTOMATIC TRANSFER SWITCH (3) #3 THWN W/ 1 1/2" CONDUIT SERVICE PANEL 200 AMP W/ MAIN BREAKER12 CIR NEMA 3R ENCLOSURE 120/240V, 10, 3W 30/2 F- POWER SOURCE O 2P + GROUND PER NEC 200A 200 AMP DISCONNECT 200/2 (3) #3 THWN W/ 1 1/2" CONDUIT DIESEL GENERATOR 200/2 GROUND PER NEC 200/2 MECHANICAL INTERLOCK 30/2 1 20/1 20/1 GROUND PER NEC PROPOSED T-MOBILE HYBRID CABLE ROUTE FROM T-MOBILE CABINET ALONG ICE BRIDGE AND UP MONOPOLE TO T-MOBILE ANTENNA LEVEL 0 ° ° OG ,° m d ° ^I � m° ° ° ° p PROPOSED T-MOBILE POWER ROUTE PROPOSED T-MOBILE TELCO ROUTE - 2" CONDUIT WITH 1 " INNERDUCT FOR FIBER, (4) SM LC TO LC (3mm) FIBER, (2) SHIELDED CAT6 (ALARMS), (2) #10 THHN DC POWER CABLES NOTE: I DESIGN IS PRELIMINARY, REFER- UCR. I w � PROPOSED T-MOBILE FIBER ROUTE FROM TELCO P.O.C. AT UTILITY POLE TO T-MOBILE H-FRAME PROPOSED T-MOBILE POWER ROUTE FROM POWER P.O.C. AT UTILITY POLE TO T-MOBILE H-FRAME oI T Mobile 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 AV AMERICAN TOWER CORPORATION INFINIGYS' FROM ZERO TO INFINIGY the solutions are endless BELLEVUE, WA 98004 r T-MOBILE SITE: SE04723A FEDERAL WAY DISTRIBUTION CENTERS ATC SITE: 91531 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 KING COUNTY 120'-0" MONOPOLE DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION OA/OC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD II 1 RESUBMITTED UTILITY ROUTING PLAN & DETAILS RECTIFIER RECTIFIER RECEPTACLE TELCO Mar 24 2021 TRAY 1 TRAY 2 SHEET NUMBER: REVISION: CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT 1 0 2 1 ONE LINE DIAGRAM SCCALE 1 UTILITY ROUTING PLAN 22"x34"SCALE: 3/4" = 1'-0" 11"x17" SCALE: 3/8" = 1'-0" 1' 6" 0" 1' THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD CABINET BATTERY EXPANSION T Mobile RED MDL 5 L1 BLK TO HEATER RELAY HEATERHEATER OPT CABINET OLSW ALARM NEWRED SWITCH L1 BLK SHELF 1 BL Li DL 1& DL 38 RED RE LGR c ® ® ® ® 19807 NORTH CREEK PKWY N RED AL1DOOR ALM G RN ON ON ON ON ON ON BOTHELL, WA 98011 BLK BLK RTN MOL 5 L1 BLK RED L2 RED J1 BLK AL2 DAC ALM L1 BLK SHELF 2 gL L1 SW1 COOL RTN DL 36 RED RE L2 DL 1& 10A ^1 A 1 A U RED FO AL3 HTR ALM G RN GR G F1�2 2 2 BLK RTN JS J7JH J3 BLU DCPP REAR VIEW BLK BL RE RE RE BLU/WHT AL4 DC ALM ACPOWER BLK AMERICAN TOWER ORG RTN CONNECTIONS F CORPORATION DAC AL5 DC MAL ALARM RTN ORG/WHT 3 2 GRN AL6 AC PWR HULOW BLK GRN/WHT_i' RTN RED 3 RE 1 AL7 BAT CAB DOOR 240VAC DINRAIL INFINIGY81 BLK HEATER ASSEMBLY J1 � DOOR OPEN � RTN (ypSW1 _ HEAT DETECT [� AILS BAT CAB DAC GREEN UO F� ., SWITCH ra „_„ WIRES L- JSJ9 J7� J6 J3 ALARM DC ALM ALARM ALARM CABLE DC PP ALM RLY PIN R T" AL9 BAT CAB CBALM RTN AL10 C� RTN [� AL11 UPPER LEVFI TERMINALS LOWER LEV TERMINALS TMGBB I F K U M L E K U I U INFINIGY fI12 SOIUfIOr15 are EITCII255 BELLEVUE, WA 98004 AL3 BLUE K10-NC 73 DC MIN AL3 RTN BLUANHT K10-C 74 AL4 ORANGE K11-NC 76 DC MAJ AL4 RTN ORG/WHT K11-C 77 %C MAINS HI AL5 GREEN K9-NC 70 /LOW AL5 RTN RN HT K9-C 7, CODEX ALARM MODULE INSIDE [; RTN 0 0 00 0000 FRONT DISTRIBUTION COVER AL12 �� ���� T-MOBILE SITE: � �� DCALARM WIRING RTN BL WHT VVHT OLACK RED SE04723A ,O 0L20 FEDERAL WAY DISTRIBUTION GRN 1 FIELD WIRING CENTERS ORG GR BL OR (AC BROWN USED) SINGLE PHASE ASE 7071 374 677 60Hz200AMAX ATC SITE: K9 K10 K11 91531 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 4 ALARM WIRING DIAGRAM NOT TO 3 AC POWER WIRING DIAGRAM NOT TO KING COUNTY SCALE SCALE NOTE: 120'-0" MONOPOLE DIAGRAMS PROVIDED ARE PER MANUFACTURER INSTALLATION GUIDE DC DISTRIBUTION -DOOR OPEN FROM VIEW DC DISTRIBUTION TERMINALS 'TIER"1 "TIER"2 "TIERS "TIER"4 "TIER" 1 OF 4(SIDE VIEW) THERMAL SVSREM ♦ THERMAL SVSREM ♦ BLK RED DAC AND HEATER DAC AND HEATER TO CABINET DC ��o m�v 1 1 FUSE BLOCK FUTURE USE (aO O ° FUTURE USE O O 0 ° DAC DOOR PWR 25� Q 0 0 • FUTURE USE FUTURE USE FUTURE USE 10A Q 0 OO O° OO OFUTURE USE 10Amoo 00 • • ♦ ♦ ♦ ♦ FUTURE USE 10A I& 0 0 DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION OA/OC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD FUTURE USE O CH) O° FUTURE USE w w O O O° 0 O (0° 0 CH) 0° O O O° 0 CH) OO ° FRONT 7*4 OO REAR 00 0° 00 (D.Oo 0° Oo (D.o0 00 00 Do 0° 00 0° Oo 0° Oo 0° o0 00 00 0° Oo 0° Oo 0° OOo 00° 00 00 � Oo 0° 00 0° 00 0° 00 0° 12°O 12 0 cm 0 ° • • PROPOSED (0 0 0 ° � PROPOSED V � CIO— r SKU # 32089 • • SKU # 32089 DC48V HOT BUS DC RETURN 0 m 0 0 • 2ND 200A 0 0 (0 o • ♦ 1ST 200A ICE PROTECTED) BUS OVF,) BREAKER BREAKER Z�il Zl O ®O O o � OCATION O ®O O o LOCATION 40 JUMPE\ •JUMPER JUMPER •JUMPER V ` 1 ° CB ALARM V o 0 01 ° CB ALARM ° CB ALARM ^ CB ALARM PIN AND SWITCH PIN AND SWITCH PIN AND SWITCH ORIENTATION PIN AND SWITCH ORIENTATION ORIENTATION "OFF" ORIENTATION "OFF" "OFF" "OFF" �. SHEET TITLE: OBSERVE CORRECT ALARM PIN ORIENTATION RESUBMITTED ELECTRICALDIAGRAMS Mar 24 2021 SHEET NUMBER: REVISION: CITY NI FEDERAL WAY J . J 0 COMMUNITY DEVELOPMENT I I 2 NOT USED SOCALE 1 DC POWER WIRING DIAGRAMTTO T TO SOCALE THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. T Mobile FROM DIN 19807 NORTH CREEK PKWY N DISTRIBUTION BOTHELL, WA 98011 DAC (COOLING) CONTROLLER A ERICAN COR OR TOON R FROM DC DIN DISTRIBUTION J1 TO CABINET Sw1 COOL ALARM BLOCK V U 8 J9 J7 J8 J3 2J4 O RED RED LIGHT ASSEMBLY ff��LIGHT BILK_ INFINIGYS' SWITCH FROM ZERO TO INFINIGY BILK NC the solutions are endless BILK N BELLEVUE, WA 98004 TO HEAT RED NC , CONTROLLER BILK C T-MOBILE SITE: DOOR OPEN 4ZE04723A COOLJ9 HEATER DETECT FEDERAL WAY DISTRIBUTION J8 FROM J7 DAC ALARM CENTERS DOOR ALARM HEATER CONTROLLER ATC SITE: FROM DC DIN DISTRIBUTION J1 O AM -Eh HEAT J8 J9 J7 �5 J8 J3 J2 J4 COHN FUNCTION JI PIWR IN J8 DELTA T JUMPER J9 OUTSIDE TEMPERATURE J7 DACFAN (LOWER) J6 DACFAN (UPPER) J3 ALARM J2 COOLING INHIBIT J4 HEAT REQUEST COHN FUNCTION JI PIWR IN J8 HEAT REQUEST J9 COOLING INHIBIT J7 UNUSED J6 HEATER FAN J3 ALARM J2 DOOR SW INPUT J4 HEATER RELAY CONTROL 91531 34301 9TH AVENUE SOUTH FEDERAL WAY, WA 98003 KING COUNTY 3 DC CABINET DOOR LIGHT POWER WIRING DIAGRAM INOT TO SCALE w J Uj J J Op � � z~ 120'-0" MONOPOLE L¢L��0O DOOR OPEN W W J J FROM a�m0Q DOOR DETECT ? O U O = RED TO LED LIGHT RED oo BLACK BLACK eWeeat DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION OA/OC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD 0 F 0 000 0(a� � � O ❑ ❑ ❑ ❑ r ' f r TO HEATER BLACK RED ° ° ° ° °� a �F ELEMENT EL BB e ACPWR BLACK V + V -48 FROM CIRCUIT RED BREAKER TO DOOR RED BLACK FROM 2/11 21 UPPER FAN V+ V_ BL RED DC 5A PLANT � ,p�40190�i TO DOOR V+ RE BILK GISC NA LOWER FAN V- DC DISTRIBUTION (BLACK WIRE JUMPERS TO FUSE POSITIONS REMOVED FOR CLARITY) SHEET TITLE: RESUBMITTED ELECTRICAL DIAGRAMS Mar 24 2021 SHEET NUMBER: REVISION: CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT . ■ 1 L 0 2 DC HEATING AND COOLING WIRING DIAGRAM SCALE 1 DC FUSE BLOCK WIRING DIAGRAM ■ SCCALE THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. GROUNDING SYMBOLS ADD 1"SCH80OR LIQUID TIGHT (AG) CONDUIT LOADED W/ T Mobile — GROUND BAR CAT5 ALARM CABLE ® GROUND ROD WITH ACCESS EQUIIPMENT CABINET [C� 19807 NORTH CREEK N 011 BOTHELL, WA 98011 e CHEMICAL GROUND ROD GROUND ROD CADWELD TYPE CONNECTION Ad(�� DC AMERICAN TOWER COMPRESSION TYPE CONNECTION CORPORATION ADD 2" SCH 80 OR LIQUID GROUNDING WIRE TIGHT (AG) CONDUIT LOADED EXISTING GROUND RING W/ 2/0 TELCOFLEX CABLE (CONTRACTOR TO VERIFY) TYPICAL: #6 AWG FROM EQUIPMENT TO GROUND BAR; #2 MECHANICAL GROUND FROM GROUND BAR TO GROUND RING, FROM METER TO EXOTHERMIC GROUND CONNECTION TO GROUND RING, AND FOR GROUND RING. CONNECTION TO GENERATOR GROUND INFINIGY8 EXISTING GROUND RING GENERATOR FROM ZERO TO INFINIGY the solutions are endless BELLEVUE, WA 98004 T-MOBILE SITE: SE04723A FEDERAL WAY DISTRIBUTION CENTERS ATC SITE: 3 GENERATOR SCHEMATIC PLUMBING PLAN NOT TO SCALE 91531 GENERAL GROUNDING NOTES: 34301 9TH AVENUE SOUTH 1. TO ENSURE PROPER BONDING, ALL CONNECTIONS SHALL BE AS FOLLOWS: FEDERAL WAY, WA 98003 #2/0 BARE TINNED SOLID COPPER CONDUCTOR: CADWELD TO RODS OR GROUND RING KING COUNTY LUGS AND BUS BAR (UNLESS NOTED OTHERWISE): SANDED CLEAN, COATED WITH OXIDE INHIBITOR AND BOLTED FOR MAXIMUM SURFACE CONTACT. GROUND TO GROUND BAR AT ALL LUGS SHALL BE COPPER (NO ALUMINUM SHALL BE PERMITTED). PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTIONS FOR GROUND BASE OF MONOPOLE (2 PLACES) CONDUCTORS. USE STAINLESS STEEL HARDWARE THROUGHOUT. 2. ALL GROUNDING CABLE IN CONCRETE OR THROUGH WALLS SHALL BE IN 3/4" PVC CONDUIT. SEAL AROUND CONDUIT THROUGH WALLS. NO METALLIC 120'-0" MONOPOLE ° CONDUIT SHALL BE USED FOR GROUNDING CONDUCTORS. ° ° ° 3. OWNER'S REPRESENTATIVE WILL INSPECT CADWELDS AND CONDUCT MEGGER TEST PRIOR TO BURIAL. MAXIMUM 5 OHMS RESISTANCE IS REQUIRED. a TIE INTO EXISTING 4. MAKE ALL GROUND CONNECTIONS AS SHORT AND DIRECT AS POSSIBLE. AVOID SHARP BENDS. ALL BENDS SHALL BE A MINIMUM 8" RADIUS AND NO ° GROUND RING GREATER THAN 90 DEGREES. 5. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER WHEN THE GROUNDING SYSTEM IS COMPLETE. THE CONSTRUCTION MANAGER SHALL INSPECT THE GROUNDING SYSTEM. 6. THE PREFERRED LOCATION FOR COAX GROUNDING IS AT THE BASE OF THE TOWER PRIOR TO THE COAX BEND. BONDING IS SHOWN ON THE ICE BRIDGE DUE TO DIFFICULTY WITH WELDING OR ATTACHING TO TOWER LEGS. CONTRACTOR SHALL ADVISE CONSTRUCTION MANAGER PRIOR TO PLACING CIGBE /q� ° �� — -� , ON ICE BRIDGE IF MOUNTING TO TOWER LEG IS POSSIBLE. O° o O e / \ a ° / \ ° ° \ o \m \ a 7. BONDING OF THE GROUNDED CONDUCTOR (NEUTRAL) AND THE GROUNDING CONDUCTOR SHALL BE AT THE SERVICE DISCONNECTING MEANS. BONDING JUMPER SHALL BE INSTALLED PER N.E.C. ARTICLE 250-30. ° 8 DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION OA/OC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD O V o ° ° p °p1 ANTENNA ANTENNA ANTENNA ASSOCIATED ASSOCIATED ASSOCIATED - ANTENNA ANTENNA ANTENNA EQUIPMENT MAST EQUIPMENT MAST EQUIPMENT MAST (I.E. RRH/TMA) (I.E. RRH/TMA) (I.E. RRH/TMA) 2/11 21 40190 o / ° #6 AWG (TYP.) #6 AWG (TYP.) GIsT o° a %NAL GND BAR GND BAR GND BAR (CIGBE) (CIGBE) PENDANT (CIGBE) TIE INTO EXISTIN I NEAR NEAR NEAR GROUND RING 1 ANTENNAS ANTENNAS ANTENNAS SHEET TITLE: ISOLATED GROUND RESUBMITTED SCHEMATIC GROUNDING ROD FOR METER -'� INSULATED GROUND (TYP.) PLANS & NOTES Mar 24 2021 GND BAR AT RAD CENTER SHEET NUMBER: REVISION: (CIGBE) WITHOUT INSULATORS CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT G — i 0 2 EQUIPMENT GROUNDING PLAN 22"x34" SCALE: 1/2"=V-0" 1 ANTENNA SCHEMATIC GROUNDING SYSTEM & NOTES SOTTO I 11"x17" SCALE: 1/4" = 1'-0" 2' 1' 0' 2' SCALE THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. NOTE: #6 AWG FROM ANTENNA GROUND BARS AT BOTTOM OF EXISTING GRADE CABLE GROUND KIT TOWERS/MONOPOLES SHALL 3/4" CRUSHED STONE, 18" DIAMETER PRECAST WELL ONLY USE EXOTHERMIC WELDS. T Mobilff FILL TEST WELL TO WITH SELF SEALING STEEL WITHIN 2" OF TOP. LID. SUBMIT SHOP DRAWINGS --7/77717 FOR APPROVAL GROUND BAR OYno 19807 NORTH CREEK PKWY N 1 4 EXISTING GRADE BOTHELL, WA 98011 WALL, ICE BRIDG CADWELD CONCRETE, OR 3 ANTENNA TOWE 2 TEST LOOP - #2 SOLID TINNED WIRE GROUND #2 AWG BCW RING GROUND #2 AWG i k Poo SOLID, TINNED BCW SOLID, TINNED AMERICAN TOWER TOWARD SHORTEST O O CORPORATION PATH TO TOWER GROUNDING SYSTEM CAD WELD OO OO 1O MAIN CONDUCTOR, COPPER CABLE NOTE: GROUND ROD INFINIGY8 TOTAL OF 2 WELLS PER SITE COPPER CLAD STEEL -VERIFY LOCATION WITH 5/8"PJx10'-0" LONG 'TWO HOLE LUG, OR EXOTHERMIC WELD TO BE O 5/8"x10' COPPER CLAD STEEL GROUND ROD PROJECT MANAGER. GROUND ROD USED WITH #2 AWG BCW TO BUILDING SERVICE O CADWELD TYPE "TA" COPPER CLAD STEEL GROUND OR GROUND RING 5/8"0x10'-0" LONG FROM ZERO TO INFINIGY O SPACED 6'-0" APART GROUND CONDUCTOR SHALL BE ELIMINATED the solutions are endless 4 CADWELD TYPE "GT" WHEN GROUND BAR IS ELECTRICALLY BONDED TO METAL TOWER/MONOPOLE STRUCTURE BELLEVUE, WA 98004 12 GROUND RING BONDING NOT TO 11 TEST WELL NOT TO 10 GROUND ROD NOT TO 9 GROUND WIRE INSTALLATION NOT TO SCALE SCALE SCALE SCALE T-MOBILE SITE: 1.) COPPER GROUND BAR, 1/4"x 4"x 20", NEWTON INSTRUMENT CO. SE04723A CAT. NO. B-6142 OR APPROVED EQUAL. HOLE CENTERS TO MATCH FEDERAL WAY DISTRIBUTION NEMA DOUBLE LUG CONFIGURATION. (ACTUAL GROUND BAR SIZE WILL VARY BASED ON NUMBER OF GROUND CONNECTIONS) CENTERS FINISHED GRADE OR PAVING. #2 AWG BCW (TYP.)-----__ TYP.) 2.) 5/8" LOCK WASHERS, NEWTON INSTRUMENT CO. MATCH SLOPE AND THICKNESS CAT. NO. 3015-8 OR APPROVED EQUAL OF EXISTING CONDITIONS__Cp 3.) WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. ATC SITE: WEED BARRIER CAT NO. A-6056 OR APPROVED EQUAL 91531 4.) 5/8-11 X 1" HHCS BOLTS, NEWTON INSTRUMENT CO. BACKFILL (SAND OR NATIVE SOIL) POST CAT NO. 3012-1 OR APPROVED EQUAL PER ASTM STANDARDS 34301 9TH AVENUE SOUTH 3 ii I� I� FEDERAL WAY, WA 98003 II UNDISTURBEDSOIL 3/4 0 KING COUNTY N F CADWELD (TYP.) 7/16" 2" 0 0 0 0 S�0 0 o GROUND RING OJ 0 0 0 0 0 0 120 -0 MONOPOLE 0 O 0 0 2 0 1 `\ I 0 0 4• ° 0 V. GROUND RING NOTES: GROUND BAR AT ANTENNA LEVEL TO BE BONDED DIRECTLY TO TOWER STRUCTURE; NO INSULATORS USED. GROUND BAR AT BASE OF TOWER STRUCTURE TO BE ATTACHED WITH INSULATORS. CONNECTION TO TOWER STRUCTURE SHALL BE PER MANUFACTURERS RECOMMENDATIONS. NOTTOTE 8 GROUND RING TRENCH SCALE 7 NOT USED SOCAL0 6 SUPPORT POST GROUNDING SOCALENOTTO 5 TYPICAL GROUND BAR SCALE TYPE TA TYPE VN TYPE NC TYPE SS TYPE W TYPE VS TYPE VB TYPE PT ?4 0444 TYPE GT TYPE GY TYPE GR TYPE GL TO ANTENNAS NOTES: 1. DO NOT INSTALL CABLE (TYPICALLY) MONOPOLE ANTENNA CABLE 12" TO 24" DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION OA/OC A 01/27/21 RCD PRELIMINARY REVIEW PD 0 02/11/21 CAP REVISED PRELIM. REVIEW PD GROUND KIT AT A BEND AND ALWAYS DIRECT a_ 120 MAx. RF CABLE TO ANTENNA RX2 TX1/RX1 GROUND WIRE DOWN TO - �F ANTENNA GROUND BAR. ANTENNA GROUND BAR STANDARD COAX JUMPER WEATHERPROOFING KIT 7CABLE GROUND KIT (TYP) WITHOUT INSULATORS, (TYP) 2. WEATHERPROOFING (SEE NOTE 3) BONDED DIRECTLY TO THE p7 SHALL BE TWO-PART MONOPOLE AT RAD CENTER _ TAPE KIT. COLD SHRINK CONNECTOR CABLE GROUND KIT #6 AWG (PROVIDED 2/1 1 21 SHALL NOT BE USED. WEATHERPROOFING CONNECTOR #6 AWG STRANDED COPPER WITH GROUND KIT TYP) ANTENNA GROUND BAR WITH INSULATORS, AT +d 40190 KIT (TYP) SEE NOTE 2 yf`x ,' �&'Gjsi��� WEATHERPROOFING GROUND WIRE (GROUNDED TO RF CABLE (TYP I BOTTOM OF MONOPOLE KIT (TYP) GROUND BAR). SEE NOTES 1 & 2 FOR ALL) "r'TIONAL GROUND KIT (TYP) EXOTHERMIC WELD ANTENNA CABLE RF CABLE TO TO EQUIPMENT (TYP) #6 AWG NOTES: EQUIPMENT AREA VIA MONOPOLE TRAY OR ICE BRIDGE FOUNDATION 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND SHEETTITLE: ANTENNA GROUND BAR, WITHOUT INSULATORS. ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. / BONDED DIRECTLY TO MONOPOLE OR TOWER 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. GROUND RIN \ 1 RESUBMITTED #2 AWG C SOLID TINN D TYPICAL GROUNDING DETAILS )021 AT ANTENNA LEVEL. TO GROUND RING 3. WEATHERPROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. ----- --j-�E Mar24 COMMUNITY DEVELOPMENT SHEET NUMBER: G-2 REVISION: 0 4 EXOTHERMIC CONNECTIONS NOT TOOCALE 3 CABLE GROUND CONNECTIONS 2 CABLE GROUND KIT NOT 1I RF CABLE GROUND SCALE S SOCALE THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD.