FEDERAL WAY, WASHINGTON
STORE NO.: 3794-242
DRAWING INDEX
GENERAL
C1 COVER SHEET
RR SPECIAL PROJECT
BUILDING CODE SUMMARY
NAME OF PROJECT
STREET ADDRESS:
PROPOSED USE:
FEDERAL WAY, WASHINGTON
34520 16th AVENUE SOUTH
RETAIL
CODES: BUILDING CODE:
2018
WASHINGTON
STATE
BUILDING CODE
ARCHITECTURAL
MECHANICAL CODE:
2018
WASHINGTON
STATE
MECHANICAL CODE
PLUMBING CODE:
2015
UPC
A5.1 RESTROOM PLANS AND DETAILS
ELECTRICAL CODE:
2020
NEC
A5.2 RESTROOM FLOOR FINISH
PLANS AND DETAILS
FIRE CODE:
2018
WASHINGTON
STATE
FIRE CODE
A5.3 RESTROOM FINISH PLANS
AND DETAILS
ACCESSIBILITY CODE:
2009
ANSI A117.1
LIFE SAFETY:
2018
WASHINGTON
STATE
FIRE CODE
ENERGY CODE:
2018
WASHINGTON
STATE
ENERGY CODE
MECHANICAL-
OCCUPANCY: M-MERCANTILE; WHOLESALE
OR
RETAIL STORE
(MAIN
USE) - SECT. 309.1
P1 PLUMBING PLANS DETAILS
AND SCHEDULES
ELECTRICAL -
El ELECTRICAL PLANS
E2 ELECTRICAL PLANS DETAILS AND SCHEDULES
TYPE OF CONSTRUCTION: VB UNPROTECTED (SPRINKLERED) PER SECT. 601 AND 602
ALLOWABLE AREA: UNLIMITED SECTION 507.3
FIRE PROTECTION: BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM AND
IS SURROUNDED ON ALL SIDES BY 60 FEET MINIMUM OF PERMANENT OPEN SPACE
AND COMPLIES WITH SECTION 507.3. UNLIMITED AREA CRITERIA IS APPLICABLE.
1 1.5 2 2.5 3 4 5 5.4 6 6.6 7 8 9 9.7 10 10.5 11 11.5 12 12.6 12.8 13 14
L I J
-F
�31 �
- - 4 4 eae
1-41 �1=
.n >Mn 1 '
r rT 2YYYYYYYYYYmIl YYYYYYYYYYYY
A5.1 A5.1 Io
II
o®o
II o®o
O®p
-
III o®o
II g®g
o®o
II
F
II o®o
®p
13
CE
1
o A5.1
C1
EB
A.2-
-
KEY PLAN
1 NTS
NORTH
REMODELED SQ FT:
EXISTING SQ FT:
DATE:
PROTO:
1)395
203818
10-18-21
195
GENERAL REQUIREMENTS
1.
ALL WORK SHALL BE DONE IN A SAFE MANNER AND IN STRICT
10. WHERE EXISTING FINISHES ARE TO REMAIN, CLEAN, REPAIR, PATCH,
ACCORDANCE WITH THE LOCAL AND/OR STATE BUILDING CODES, AND
AND/OR REPAINT AS NECESSARY TO BLEND WITH ADJACENT
ALL APPLICABLE CODES, REGULATION, ORDINANCES, AND AUTHORITIES
SURFACES. COORDINATE WITH WALMART CONSTRUCTION MANAGER.
HAVING JURISDICTION.
11. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE TIMELY
2.
EACH CONTRACTOR AND THEIR SUB -CONTRACTORS ARE RESPONSIBLE
ORDERING OF MATERIALS TO PROHIBIT DELAYS OF THE
FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND
CONSTRUCTION SCHEDULE OF THIS PROJECT. IT IS THE
SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT
RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE DELIVERY OF
HIMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE HIM OF ANY
MATERIALS IN A TIMELY MANNER.
RESPONSIBILITY FOR PERFORMING HIS WORK PROPERLY. NO ADDITIONAL
COMPENSATION SHALL BE BECAUSE OF CONDITIONS THAT OCCUR DUE
12, THE GENERAL CONTRACTOR SHALL RESPOND TO ALL REQUIREMENTS
TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE.
OF THE ARCHITECT FOR VERIFICATIONS, RESPONSES AND
SUBMISSIONS.
3.
THE EXISTING BUILDING SHALL BE PROTECTED FROM MOISTURE, DUST
AND DEBRIS. INSTALL DUST PARTITIONS OR DRAPES AS REQUIRED
13. DURING ENTIRE CONSTRUCTION PERIOD, PROVIDE ONE U.L. LISTED
AND/OR DIRECTED BY THE WALMART CONSTRUCTION MANAGER TO KEEP
2A-20BC DRY CHEMICAL FIRE EXTINGUISHER, OR ONE STANDARD U.L.
DUST AND MOISTURE FROM THE OPERATING AREAS OF THE STORE.
LISTED 2-1/2 GALLON WATER (E-10) AND ONE U.L. LISTED 1013C
4.
ANY DAMAGE TO WALMART PROPERTY, WHICH OCCURS DURING THE
CARBON DIOXIDE FIRE EXTINGUISHER MOUNTED TOGETHER IN EACH
PROCESS OF CONSTRUCTION, SHALL BE REPAIRED/REPLACED AT NO
3000 SQUARE FOOT OF WORK AREA OR FRACTION THEREOF (MINIMUM
ADDITIONAL COST TO WALMART, THIS INCLUDES ALL MERCHANDISE.
OF TWO AVAILABLE IN ALL CONSTRUCTION AREAS AT ALL TIMES).
THE CONTRACTOR SHALL PAY WALMART THE RETAIL COST FOR ALL
14. IF MODIFICATION TO SPRINKLER SYSTEM IS REQUIRED, THE GENERAL
DAMAGED MERCHANDISE.
CONTRACTOR SHALL HIRE A LICENSED SPRINKLER CONTRACTOR.
THE CONTRACTOR IS TO SUBMIT SIGNED AND SEALED SPRINKLER
5.
THE CONTRACTOR SHALL KEEP WORK AREA CLEAN AND FREE OF
DRAWINGS FOR APPROVAL TO THE AHJ PRIOR TO ANY ALTERATION
DEBRIS AND SHALL REMOVE ALL TRASH AND DEBRIS FROM THE
OF THE AUTOMATIC SPRINKLER SYSTEM.
CONSTRUCTION AREA DAILY. NO FLAMMABLE MATERIALS OR LIQUIDS
MAY BE STORED IN THE EXISTING BUILDING OR CONSTRUCTION AREAS.
15. THE CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE EXISTING
BUILDING SECURITY AT ALL TIMES. THIS INCLUDES KEEPING THE
6.
REMOVE ANY EXISTING ITEMS, SERVICES, FINISHES OR SURFACES AS
BUILDING SECURE FROM PERSONS, ENVIRONMENTAL ELEMENTS OR
REQUIRED FOR THE INSTALLATION OF NEW CONSTRUCTION. PROVIDE
HAZARDS. THE CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN
FURRING FOR CONDUITS AND PIPING, SHOWN OR NOT, AND FINISH OUT
THE INTEGRITY OF ALL EXISTING SECURITY SYSTEM. THE CONTRACTOR
FURRING TO MATCH ADJACENT FINISHES.
SHALL OBTAIN PERMISSION FROM THE STORE MANAGER PRIOR TO THE
MODIFICATION OF ANY EXISTING SECURITY SYSTEM FOR THE OPENING
7.
ALL ADJACENT TENANT SPACES SHALL REMAIN IN SERVICE DURING
(DEMOLITION) OF ANY EXTERIOR WALL.
DEMOLITION AND CONSTRUCTION.
16. FIRE ALARM DRAWINGS TO BE FURNISHED AND INSTALLED BY
8.
SCHEDULE ALL WORK TO KEEP DISRUPTIONS TO THE STORE
WALMART ALARM SERVICES.
OPERATIONS AT A MINIMUM. COORDINATE UTILITY DISRUPTIONS WITH
THE WALMART STORE MANAGER,
17. CONTRACTOR TO MAINTAIN ACCESS TO ALL EMERGENCY EGRESS EXITS
DURING CONSTRUCTION OPERATIONS.
9.
REPAIR, RE-ROUTE, AND EXTEND ALL SERVICES, PIPING, CONDUIT OF
EXISTING ITEMS AND EQUIPMENT AS REQUIRED DURING THE
18. CONTRACTOR RESPONSIBLE FOR PERMITS AND TRADE LICENSES
CONSTRUCTION PROCESS FOR THE COMPLETE INSTALLATION AND
THROUGH LOCAL JURISDICTION.
OPERATIONS OF NEW EQUIPMENT. THIS INCLUDES ALL ITEMS SHOWN
OR NOT SHOWN ON THE DRAWINGS. RESET EXISTING EQUIPMENT OR
RELATED ITEMS AS REQUIRED FOR PROPER OPERATION.
SITE VERIFICATION
DEMOLITION NOTES
REQUIREMENTS
1.
THE ARCHITECT HAS PREPARED THESE DRAWINGS BASED ON THE
1. CONTRACTOR IS RESPONSIBLE FOR ALL JOBSITE SAFETY AND
EXISTING BUILDING CONDITIONS. IT IS THE RESPONSIBILITY OF THE
COMPLIANCE WITH REGULATIONS. CONTRACTOR SHALL INSTALL
CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS PRIOR TO THE
TEMPORARY WALL, DUST BARRICADES AND CONSTRUCTION BARRIERS
SUBMISSION OF HIS BID AND THE COMMENCEMENT OF ANY WORK. NO
AND TAKE ALL PRECAUTIONS TO PROTECT CUSTOMERS AND
ADDITIONAL COMPENSATION WILL BE PAID DUE TO THE CONTRACTOR'S
ASSOCIATES FROM CONSTRUCTION OPERATIONS.
FAILURE TO ACQUAINT HIMSELF WITH EXISTING SITE CONDITIONS WHICH
INCLUDE, BUT ARE NOT LIMITED TO EXISTING WALL, CEILINGS, OR
2. THE CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF
UTILITIES.
DEMOLITION. IF DISCREPANCIES ARE FOUND, CONTACT THE
CONSTRUCTION MANAGER.
2.
ANY DISCREPANCY WITH THE EXISTING SITE CONDITIONS AND/OR THE
DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT
3. WHEN UTILITIES ARE REMOVED, CAP AND SEAL A MINIMUM OF 8"
FOR CLARIFICATION AND INSTRUCTION, THESE CONSTRUCTION DOCUMENTS
BELOW FINISH FLOOR OR A MINIMUM OF 6" ABOVE FINISH
HAVE BEEN DESIGNED AND DRAWN ASSUMING EXISTING BUILDING
CEILING.
CONDITIONS MATCH THE ORIGINAL DRAWINGS. IF DISCREPANCIES ARE
FOUND BETWEEN WHAT IS SHOWN ON THE DRAWINGS AND EXISTING FIELD
4. SAW CUTTING OF EXISTING CONCRETE WILL BE COORDINATED WITH
CONDITIONS, CONTACT THE WALMART CONSTRUCTION MANAGER AND THE
STORE MANAGER FOR APPROPRIATE HOURS TO MINIMIZE CUSTOMERS
ARCHITECT IMMEDIATELY TO DETERMINE WHAT ACTION SHOULD BE TAKEN
DISTURBANCE. NO JACKHAMMERS ARE ALLOWED.
TO MATCH EXISTING CONDITIONS.
5. GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF
3.
ALL UTILITY LOCATIONS SHOWN ARE APPROXIMATE. THE CONTRACTOR
CONSTRUCTION WASTE AND DEBRIS. DO NOT USE STORE DUMPSTERS.
SHALL FIELD VERIFY THE EXACT LOCATION OF ALL EXISTING UTILITIES
PREVENT CUSTOMERS AND ASSOCIATES FROM CONTACT WITH
(WHETHER SHOWN OR NOT) O HE SUBMISSION OHIS BID OR
( TT ) PTTF
CONSTRUCTION WASTE.
THE COMMENCEMENT OF CONSTRUCTION. THE CONTRACTOR SHALL
NOTIFY THE WALMART CONSTRUCTION MANAGER AND THE ARCHITECT
6. COORDINATE LOCATION OF DUMPSTER ON SITE WITH WALMART
OF THE DISCOVERY OF EXISTING UTILITIES NOT SHOWN OR NOTED ON
CM.
THE DRAWINGS.
4.
THE CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND
DEPTHS OF UNDERGROUND UTILITY SERVICES PRIOR TO ANY
EXCAVATION.
SCOPE OF WORK
5.
REPORT ANY DISCREPANCIES FOUND IN THE FIELD IMMEDIATELY TO
WALMART AND THE ARCHITECT PRIOR TO MAKING ANY MODIFICATIONS
1. REMODEL CUSTOMER RESTROOMS
OR ORDERING OF ANY MATERIALS.
RECEIVED
Oct 26 2021
CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
0
0
p+enb2
hitecture
gineering
2809 Ajax Avenue Suite 100
Rogers Arkansas 72758
Phone: 479.636.3545
Fax: 479.636.1209
Architect of Record
William Douglas Hurley
Washington License No. 8855
Unified Business ID No. 602 491 668
W W - 0
LJ ~~W 20Z(/�
O NZ�. Owe~=Q
Z
Wri� wa �liOQ �370N¢w¢�pWQ+w¢
~p
'M0 OW¢
UZ�
N0=Ja6,<ajo�ao
<�Fap
ZQ3,o`�wa"O <;aat0oZ00 (A w>-Oz /Q v�U}NQ 3¢3o- w03a�Y
pZO<WomwwOzwwwzwm
W H IN¢ W 0-Z 3
(nwOZtoWWOOC7¢O}
X: (A W 0ov�ia�waawoa'5
z r-
0
0
Z=
(� 0
U71 N O
w I o
zCY)
LLJ > r0
� a
Q O�
0 LL1 0
� IY
__]00
N 1-o
Ln in N
L_L ]
w
m
L_L ]
LL z
m
RR SPECIAL PROJECT o
ISSUE BLOCK
CHECKED BY:
SB
DRAWN BY:
AMR
PROTO CYCLE:
09-24-21
DOCUMENT DATE:
10-18-21
8855
WILLIAM DOUGLAS HURLEY
STATE OF WASHINGTON
0.18.2021
DOCUMENTS THAT DO NOT HAVE
THE ARCHITECT OR ENGINEER OF
RECORD SEAL AND SIGNATURE
SHALL BE CONSIDERED NOT FOR
CONSTRUCTION
COVER
SHEET
N �t
O c-)
N �
Ln /
�0)
-,0-)
0 0-)
I
o O
w O
O
Z N
ARCHITECTURAL:
MECHANICAL/ELECTRICAL/PLUMBING
BUILDING REVIEW:
STORE ADDRESS:
pb2 architecture + engineering
RTM ENGINEERING CONSULTANTS
CITY OF FEDERAL WAY
WALMART STORE NO. 3794
2809 AJAX AVENUE SUITE 100
3333 EAST BATTLEFIELD ROAD
PERMIT CENTER
34520 16th AVENUE
ROGERS, ARKANSAS 72758
SUITE 1000
33325 8th AVENUE SOUTH
FEDERAL WAY, WASHINGTON 98003
(479) 636-3545
SPRINGFIELD, MISSOURI 65804
FEDERAL WAY, WASHINGTON 98003
(417) 881-0020
(253) 835-2607
SHEET:
C 1