00-103141 (2) CITY OF = • .1173 Iy CITY HALL 33530 1st Way South (253) 661-4000 PO Box 9718 Federal Way, WA 98063-9718 September 11,2002 Bryan White Pageantry Communites 25400—74th Avenue S Kent,WA 98032 RE: Permit#00-103141-000-00-EN; TRESDEN PLACE 2920 S 298th Street; *Sight Distance Mitigation* Dear Mr White: I am responding to the letter sent by Tim Holderman, P.E., dated August 12, 2002 regarding the Military Road and S 298th Street sight distance issue. Regarding the mitigation for this area; we concur with his proposed mitigation of re-contouring of the existing slope in conjunction with further reduction of wall height. Since the current conditions are less than the original sight distance conditions, the current sight distance conditions must be improved to approximate the original conditions. The contractor chosen by Pageantry Homes will be required to perform this action. This work will be specified as a punch list item. The extent of re-contouring of the slope and further reduction in wall height on the west side of Military Road shall be determined by your engineer, with concurrence from the City of Federal Way Public Works Department. The recommendation of reduction of the posted speed submitted by Mr. Holderman would have to be approved by City Council. It is very doubtful that this recommendation will be favored by City Council, as the posted speed along this portion of Military Road is consistent with the remainder of this route. It has also come to our attention that the required streetlights along the Military Road frontage remain uninstalled. If streetlights are not installed by the end of this month, Public Works will begin the process of contacting your bonding company and arranging to have this work completed. Please call if you have further questions. Sincerely,4c,„sraAzi&v Kim Scattarella, P.E. Senior Engineering Plans Reviewer KS:tm cc: Jim Femling,Development Services Manager Tim Holderman,P.E.,Sound Engineering Inc., 1019 Pacific Ave.,Tacoma,WA 98402 Rick Perez,P.E.,Traffic Engineer Project File Day File I:\c sdc\docs\sa ve\24943994094.doc ` ,/ 6 Z DOUjf,2� -i TO: ,5"/ s kz CITY OF FEDERAL WAY LAW DEPARTMENT REQUEST FOR CONTRACT PREPARATION/DOCUMENT REVIEW/SIGNATURE ROUTING SLIP 1. ORIGINATING DEPT./DIV: V/[.. -1/e Wire.it L, '/r " /c f S 2. ORIGINATING STAFF PERSON: j))) .Wtl/Zt,` `i -EXT: 7l},z-- 3. DATE REQ.BY: /2- /OJ 4. TYPE OF DOCUMENT REQUESTED(CHECK ONE) ❑ PROFESSIONAL SERVICE AGREEMENT 0 SECURITY DOCUMENT(E.G.AGREEMENT& O MAINTENANCE/LABOR AGREEMENT PERF/MAIN BOND;ASSIGNMENT OF FUNDS IN LIEU OF BOND) ❑ PUBLIC WORKS CONTRACT ❑ CONTRACTOR SELECTION DOCUMENT ❑ SMALL PUBLIC WORKS CONTRACT (E.G.,RFB,RFP,RFQ) (LESS THAN$200,000) 0 CONTRACT AMENDMENT AG#: O PURCHASE AGREEMENT) 0 CDBG (MATERIALS,SUPPLIES,EQUIPMENT) OTHER -kt 1t/L-t. Ka, l',C 0� Ord ❑ REAL ESTATE DOCUMENT . 5. PROJECT NAME:'/fit-`4(j ) [WC"" " / )/L / p/(t && - - 6. NAME OF CONTRACTOR: ( cti/J// i(� if)///,-/ifi C, tL,ii5i111Li;fIa"L. ADDRESS: 9A C l -- 1 -A f"i G ,.-2i(II 1 j i 1., 1. L.•j e� e�� TELEPHONE SIGNATURE NpAMME: i.) 1 11 i")/t t', TITLE A ZS/ElC'/L 7. ATTACH ALL EXHIBITS AND CHECK BOXES 0 SCOPE OF SERVICES )(ALL EXHIBITS REFERENCED IN DOCUMENT ❑INSURANCE CERTIFICATE XDOCUMENT AUTHORIZINGSIGNATURE 8. TERM: COMMENCEMENT DATE: COMPLETION DATE: 9. TOTAL COMPENSATION$ (INCLUDE EXPENSES AND SALES TAX,IF ANY) (IF CALCULATED ON HOURLY LABOR CHARGE-ATTACH SCHEDULES OF EMPLOYEES TITLES AND HOLIDAY RATES) REIMBURSABLE EXPENSE: ❑YES 0 NO IF YES,MAXIMUM DOLLAR AMOUNT: $ IS SALES TAX OWED ❑YES ❑NO IF YES,$ PAID BY: ❑CONTRACTOR❑CIT 10. .CONTRACT REVIEW INITIAL/DATE APPROVED INITIAL/DATE APPROVED PROJECT MANAGER 372 71 ' DIRECTOR f i �'r r Z e I61 4-/. f(' 1' ‘141u-2., ❑ SK MANAGEMENT i LAW ` �('CL`` I)/ l/± I�`'J I i !o']P? al I''((G ` i-1L1/LJ �1 S;!j)k 1 ' 6 /t 11. CONTRACT SIGNATURE ROUTING/ om. 6 INITIAL ATE APPROVED INITIAL/DATE APPROVED X LAW DEPARTMENT' ,"/` '-h1e LT/!:' '_ 6, 0 CIIT -f'TY MANAGER /-:(.(, ,ifte/(1).-, / /° - -CLCi i Y CLERK �tj --- 0)1._❑ SIGN COPY BACK TO ORGINATING DEPT. r ❑ ASSIGNED AG# U PURCHASING: PLEASE CHARGE TO: o le-Papa/IL lfil a- . COMMENTS 04/04/02 • CONFORMED COPY Return Address: _ Cityof Federal Way20020711000744w Attn: Law Dept. PAGE 001 OF 007 33530 1st Way S. KINGiCOUNTY12WA2 PO Box 9718 Federal Way,WA 98063-9718 E1897167 • 07/11/2002 12:12 KING COUNTY, WA 00 SALE i0.00 PAGE 001 OF 006 STATUTORY WARRANTY DEED Grantor(s): PAGEANTRY COMMUNITIES OF WASHINGTON Grantee(s): CITY OF FEDERAL WAY Property Legal Description(abbreviated): W '/2,N 659.69',NE1/4, SE 1/4, SEC.4,T 21 N,R 4 E,W.M. Additional Legal(s)on Exhibit A Assessor's Tax Parcel ID#(s): 042104-9078 and 042104-9079 THE GRANTOR(S), PAGEANTRY COMMUNITIES OF WASHINGTON, a Washington corporation, for and in consideration of the City of Federal Way's approval of final plat #02-101104-000-00-SU and other good and valuable consideration,convey(s) and warrant(s)to the CITY OF FEDERAL WAY, a Washington municipal corporation, all of its right, title and interest, and any after-acquired interest therein, in and to the following described real property situated in County of King, State of Washington: Full legal description of property attached hereto as Exhibit"A," and incorporated herein by this reference. DATED THIS 21st day of May, 2002. GRANTOR: PAGEANT OM TIE W INGTON on White,Presi ent 25400 74th Avenue South Kent, WA 98032 • STATE OF NEVADA ) ) ss. COUNTY OF CLARK ) On this day personally appeared before me Don White, to m known to be the President of Pageantry Communities of Washington, the corporation that executed the foregoing instrument, and acknowledged the said instrument to be the free and voluntary ac and deed of said corporation, for the uses and purposes therein mentioned, and on oath stated that he was authorized to execute said instrument and that the seal affixed, if any, is the corporate seal of said corporation. GIVEN my hand and official seal this A/ day o /1 , 2002. Notary �gi ature Typed/Printed Name of Notary) Notary 'State of N6Yi'r S% ± County of Clark Notary Public in and for the State of Nevada. __r AEt_I4SA I COSSE ..`,S- My Appointment Expires My commission expires - No:99-a 9 -1 March 12,2003 I:\csdc\docs\save\1 4 662 1 79009.doc G:\Iawfomis\deeddev.doc 01/29/02 Exhibit - A C/ Tresden Place Description of Roadway Dedication in the City of Federal Way,Washington That portion of the following described parcel: The west half of the north 659.69 feet of the northeast quarter of the southeast quarter of Section 4,Township 21 North,Range 4 East of the Willamette Meridian,in King County,Washington,lying north of Old Military Road; EXCEPT the south 30 feet thereof for South 298th Street. EXCEPT that portion deeded to the State Of Washington for highway under Recording Number 4986691. Described as follows: COMMENCING at the northeast corner of the southeast quarter of said Section 4; thence North 89°50'12" West,along the north line of said southeast quarter,a distance of 653.68 feet to the northeast corner of the above described parcel; thence South 00°17'15" East,along the east line of the above described parcel,a distance of 599.71 feet to a point on the north line of that certain parcel of land deeded to the State Of Washington for highway under Recording Number 4986691; thence North 89°50'12" West,along said line,a distance of 21.40 feet to the northwest corner of said parcel; thence South 00°09'48" West,along the west line of said parcel,a distance of 30.00 feet to the northerly margin of South 298th Street; thence North 89°50'12" West,along said northerly margin,a distance of 65.47 feet to a point hereinafter referred to as Point"A" and the beginning of a curve tangent to said line, said point being the True Point of Beginning; thence westerly, northwesterly and northerly a distance of 20.32 feet along the curve concave to the northeast,having a radius of 13.00 feet and a central angle of 89°32'57"; thence North 00°17'15" West tangent to said curve,a distance of 431.80 feet to the beginning of a curve tangent to said line; thence northerly and northeasterly a distance of 20.59 feet along the curve concave to the southeast, having a radius of 25.00 feet and a central angle of 47°11'47" to a point of reverse curvature; thence northeasterly,northerly,northwesterly,westerly and southwesterly a distance of 170.15 feet along the arc of said curve concave to the southwest having a radius of 53.00 feet and a central angle of 183°56'31" to a point of reverse curvature; thence southwesterly and westerly a distance of 20.59 feet along the arc of said curve concave to the northwest having a radius of 25.00 feet and a central angle of 47°11'47"; thence North 89°50'12" West tangent to said curve,a distance of 176.50 feet to the beginning of a curve tangent to said line; thence westerly and southwesterly a distance of 153.87 feet along the curve concave to the south,having a radius of 208.00 feet and a central angle of 42°23'08"; thence South 47°46'40" West,a distance of 195.01 feet to a point of cusp on a curve concave to the southwest having a radius of 2331.01 feet and a central angle of 0°15'58" and being subtended by a chord which bears North 38°10'54" West 10.83 feet, said curve being 39.00 feet northerly of the centerline of Military Road South; thence northwesterly along said curve,a distance of 10.83 feet to a point of cusp with the west line of the above described parcel; thence South 00°14'51" Fast,along said line,a distance of 14.64 feet to the northerly - margin of Military Road South at a point of cusp on a curve concave to the southwest having a radius of 2322.01 feet and a central angle of 9°58'20" and being subtended by a chord which bears South 33°02'39" East 403.63 feet; thence southeasterly along said curve and road margin,a distance of 404.14 feet to a point on the south line of the above described parcel; thence South 89°50'11" Fast,a distance of 10.21 feet to a point of cusp on a curve concave to the southwest having a radius of 2331.01 feet and a central angle of 0°23'50" and being subtended by a chord which bears North 28°08'17" West 16.16 feet, said curve being 39.00 feet northerly of the centerline of Military.Road South; thence northwesterly along said curve,a distance of 16.16 feet to a point of cusp on a curve, from which the radius point bears South 79°39'40" East; thence northerly and northeasterly a distance of 19.91 feet along the arc of said curve concave to the southeast having a radius of 23.00 feet and a central angle of 49°35'16" to a point of cusp on a curve,from which the radius point bears South 07°51'44" East; thence easterly and southeasterly a distance of 120.02 feet along the arc of said curve concave to the south having a radius of 150.00 feet and a central angle of 45°50'41" to a point on the south line of the above described parcel; thence South 89°50'12" East,along said south line,a distance of 221.86 feet to the True Point of Beginning. EXCEPT the following described parcel: Commencing at the above described Point"A"; thence North 89°50'12" West,along the northerly margin of said South 298th Street,a distance of 68.90 feet; Sheet-2 /;/ thence North 00°17'15" West,a distance of 13.34 feet to the True Point of Beginning. thence North 00°17'15" West, a distance of 447.47 feet to the beginning of a curve tangent to said line; thence northerly,northwesterly and westerly a distance of 20.32 feet along the curve concave to the southwest,having a radius of 13.00 feet and a central angle of 89°32'57'; thence North 89°50'12" West tangent to said curve,a distance of 193.05 feet to the beginning of a curve tangent to said line; thence westerly and southwesterly a distance of 112.44 feet along the curve concave to the south,having a radius of 152.00 feet and a central angle of 42°23'08"; thence South 47°46'40" West tangent to said curve,a distance of 2.39 feet to the beginning of a curve tangent to said line; thence southwesterly,southerly and southeasterly a distance of 20.42 feet along the curve concave to the east,having a radius of 13.00 feet and a central angle of 90°00'00"; thence South 42°13'20" East tangent to said curve,a distance of 44.38 feet to the beginning of a curve tangent to said line; thence southeasterly and easterly a distance of 20.59 feet along the curve concave to the northeast,having a radius of 25.00 feet and a central angle of 47°11'47"to a point of reverse curvature; thence easterly,southeasterly,southerly,southwesterly,westerly,northwesterly and northerly a distance of 253.82 feet along the arc of said curve concave to the northwest having a radius of 53.00 feet and a central angle of 274°23'34"to a point of reverse curvature; thence northerly and northwesterly a distance of 20.59 feet along the arc of said curve concave to the west having a radius of 25.00 feet and a central angle of 47°11'47"; thence North 42°13'20" West tangent to said curve,a distance of 44.38 feet to the beginning of a curve tangent to said line; thence northwesterly,westerly and southwesterly a distance of 20.42 feet along the curve concave to the south,having a radius of 13.00 feet and a central angle of 90°00'00"; thence South 47°46'40" West tangent to said curve,a distance of 102.32 feet to the beginning of a curve tangent to said line; thence southwesterly and southerly a distance of 14.42 feet along the curve concave to the southeast,having a radius of 23.00 feet and a central angle of 35°54'42"to a point of cusp on a curve, from which the radius point bears South 53°26'27" West; thence southeasterly a distance of 256.16 feet along the arc of said curve concave to the southwest having a radius of 2331.01 feet and a central angle of Sheet-3 6°17'47" to a point of cusp on a curve,from which the radius point bears North 21°03'42" East; thence easterly a distance of 5.49 feet along the arc of said curve concave to the north having a radius of 23.00 feet and a central angle of 13°40'26" to a point of cusp on a curve,from which the radius point bears South 17°55'55" East; thence easterly and southeasterly a distance of 219.42 feet along the arc of said curve concave to the south having a radius of 210.00 feet and a central angle of 59°51'59" to a point of reverse curvature; thence southeasterly and easterly a distance of 100.61 feet along the arc of said curve concave to the northeast having a radius of 150.00 feet and a central angle of 38°25'48" to a point of compound curvature; thence easterly,northeasterly and northerly a distance of 21.28 feet along the arc of said curve concave to the northwest having a radius of 13.00 feet and a central angle of 93°47'30" to the True Point of Beginning. a�axn v # '�rt�cE 14,41/4 hL LAB+ Sheet-4 * . . • \ • ---- •, 1 ' •• — . ... ... ...1': • ri . . • • 1. . . 'i ........ , . ." • • 4.::.i .... •,* .<^i :1 • ..,.. :e<..C4' .A :',z-- •••• : .. . 4: ••••/.-A- • I 45: ':: ': I'''. :,• .„.,••- :-s-C>: -.e'r % t - F •-• : i•:. :: . :• •• ••q, . .:-: - :•,‘. i..,,;3-:• -:•/-";?- '3.: A ••• "-.., . .................. ................•.• ,, . .. •:;•.,-;-•''''''' 4••• •;;•••,.:•: •\: --... • - . ,..,•••:•-- --... . • ••," • ... - \ . .•Sd•titai...2..0.4.tli:•.':gt,X.5.00t•............., . 2 7: -,/./. - • • -;‹,.„ : . .: •i,..?. . .• :-• . .: . . • .•••, -, I -.1-7,-- ,,,-..‹. •.,..„...-.,. ,-,...,,... :: : . .. ...1 A-• •-•1 7-..• •••-::.,••• ] •:.:-•::•-•- .:::. - --•:•:•: 1:••• :• • •• - --. ' •;: . . •• • . . . . . „ .., ,.: : •.• ri . • . - •Ne.z.\;$\.4 •• • .•: :. 4.4.,.--- ..i. .•• 0 : • .....„ ..... : . .• .. . . .. . „. . . . • • • • . ..;••,- .4t ..1.•:..t. ; :-•14 .. • -......,...,—... . . -..:,••r•• , ,•••••-: . - ../.- . - ../: vC11,6,.• •!70 , - -- - ::4•1:4::: : :...•,• \' i fea •• i -.;• -:.„-..„4„...„„....,„,......„._.........._ .. . : :,•••••;••••5 ,-: - .• „ .,, „. • AZt.4" .1 - . .....:-:: . ., .. '''' ,,, ''.:.s..,..;, '--;.„,;,.. :: 4-4: ; - ..5.Z.‘c. - • / ... ..: . 44 .i, N. ...,... .y5:. ; •i-.,,,: -0: .. , . .. . . •./.': •-":!..4..r * ..7,,,,. - . y: ‘,.....4 • •Crl \\,. .. • :• -.. •;;:- ./: f...4....i.... S .%-. . f.. -',..,..,..::is,•f*"...,.:- 1;.: • -\ -• *. •.. '.• :...:)..r)• 1: .;..*.„ •A: .Z.7 .... .. . . .?:: :. ... :.- • - • • - i. . *-‘..'%s;... -i • .. .• 1 .:.:.- . ./:•N .- .•:;::: -. :c.. . ',.„-:-.,''''''''...:•-""•. . ----. , :Crt., .4 . ..., .:a.A.. :, : :. ,. •.;: ]:, ...:: ., .........„.....,,,... . . ie:-. - . .. •: . ... ... . i, ..-, .. 1 . :.: . . •. ,v . . .4...„... .t. 4:15. s 4 4: ...,. "I'P - . . • b., :.'. - '- ::: --- ' :4.01 • 9.6.".-: - .: . i ... 1 4••'••3 a_ ,......„ •••-t . '.--• •••• - 1 .. :.t. :•• ;-• • ::•"" •• - • .. . • .,.. •,•- •• •f-• ' 4:4:: i 3... ...„.. - -. I: .,,„„,:„........... ••• •* *. ** .. . .. -:*- • - --"- -•49 :::... *: .. ., . ***,,,, * • *. ..),\ i* . -..—_.s„. -•-•• * .. .. ' ''';::; .r ' -......_ $03.1,th 2•9etb: •Street f•—.., i . .. , . .. .•.: , - -..•&4'...q.2S.v;vs..••• .... . .. .. .,..„ . . .: ..,.:-..-:... .....E..., ..-:: : . • (::: A q :-.•: .. *.:•A:.:ii:. i . .- ...:k• _.0,._ .,,Q. -.s,.. . :, .., :: - t4, ....• 4fr If 4.,. Not to scale , :4-v.: ...-..„:: . • . ..: :::, 4:;:,:... . :• .... - -,-,--.4 „,: li •:.k,:- ..:.,.-:-a... .....,,,..•. ....: :. ,:„.v.: '-r i . ‘,7a•-... :72:118 : ......„.t.,-. , ti.•-•.1.,t .. .-.:,4=4. ,4., ,z . :: ...4.:( i'.1„0:.•-./ R • ••••:1 ,: r : ..:-.:-:.--:: :.. . .._. 4 exfs..I.2:,,,,;:•1-6 ,.. ..460-Z.5 , ... .., • . o al c u >- Q ua U 2 az 3 y�,j >C N 7C y a7 Lx64 q cOi o F 'S ^ Q G o cea v :A a aO ° � E `' .v, - ,� o0 0 Z a.),..-NE GC o .O ;u co 4-1 u O Q a,` J C 3 a. D, N of ° g S•' w as �'. '� rr r f C a�` 1 >: O .O +a 0 F.< O N 6J 'y C7 >.:Y 1J(�. g >' a} t;1 > �•. 'n N e0 CO C ,O Z c,..i . \, r 3 i .,l O a 4 C 0 vi U d a O CII 0. �i} N W N c a O Z ,� O - Y+ RI O V•.\ c Y rr F• L,. a0i v ?, O a: w as O a3 O a v tA.��' s t O 0 U L a3 a O r- .O 0 c E y b c4 > C �. ( a i 4 ;,_: F- 3 n F '� a u SOa a`i �+ N fA O 0 O d 41 04 ¢ Q` \ ~ r $ t o .•., cn 0 ^ G C .0 �.' U %? -� j a� 1�\.. :L' i� ,` 4:3.` f-?' 8 • a g .a [n y,a T C Ls E 0 3>•, N H9 t9 es 69 69 69 vi bs 99 d w c r0 w u "a `� •, ;.}.,, ¢7 U 'r, z cd a� C .T Ci 0 ^ N ^ O as is .2 is .>' g - Q O 'y � a: 0 6 0 O E •O �' y `� .� is ca ca c> 7 a �,^ rf r, O ~t7 �+ r� 0'3 as 3 < "� 0 "' a. •aO a`, v} o 0 o a A A a -.K r '•:� o p . `° U sv c O ai 3 .p �, u .a -a a 00 a �' . ✓ L. ;z u m as •aV 4-4 "U 3 cC — - 0 u �s y a. O a} y cc b+ 9, 4-$ O A. A •� -, y C H 0 c �? J r oD c +` 0 0 '}3 C w E y Lt..) vr. 0 CA .`s.; as y 0 cy O C7� •. rn Li 0 Q} z y .a.. O Ll 'L1 7 W� C V} N V] F-+ N O' 69 >' 67} _• • fG a[al D, SJ Gr Ct co ? a) ti to o a '' `� "It U s p; u op cn ni r` } o.° o AGO 3.), a' . O y 0 a' v e O 2 7 g c A d k-r . m U C c- 'O a .r.3 +.a E a ce, Yr e a o .o '- _ as w ..r ¢ N ,, 0 A en C• ¢ o,. J, c,.- o 1-4 G 'c_, . c, a' Q) C7 °» X x C p a ° o ° 4 -o 6 W 3 U 3 .. C s r� d I C abi W cs y S., '� 9 9 C F W 7 - r__. °� CUa u- a) v Lir ;o O CA x O c, d c_,c ^o !+ c v U U o O• c c o .oO. op c03 o 03 •„W . Q a 3 �_ •� u a p E J ai o. c ° A Ca , as 5 T q a' 4 0. 'O `3 �'+ .� a a s cn oe W Q co .13 b -j N ra ''� c''aO a0i C. 3 z `° `" �^ °-� A w C 3 « _ .. ° Y .' Oe m w Z rn U a ,7 .�' A .O ss N ,. E C ° p Q -g .a •^ ca O y C al E as y .en , �i a © xna w 3 F- 3 �- �o� m () 3 ... z O a3 � y�!� �!-� y� as •y a b o 1 0 O Ys • ' 2 O Z "LJ lJ LJ LJ 5 E is M O U ' oO,c .. W U = A O ui 'd 2 'S v c N c a o y a o F 0 W 0 u en 0 of 'E 9 as 4- c o a., y a) "E .5 a2i . 3 0.�'. co H `� a`" W °° o ❑ .0 p -o ° o to o �- k .0 c ° U 'o N °, -....` esi V�i U '' v 3 p >, •5 U G -- .o O�- `' c" y 'ca .a N 6 8 CG N `� ch y '\ LL . � Faa w a w CO w A c x as OitIUiiH _. 3 a �, ooc� ist O W C 3 I3 3 .� M U 3 O ¢ as ° �O i} E C) Ub OM U GC Q 0 E a; 4: c> o N ° \ t7 1 d o z a O Ca C U t� p �, U °o aOa c ri 4 y ° .. `' a v E" a o.a w o u F... Y+ a+ a;r, ❑❑❑ �❑❑ 3 0 . Y _ c Q >, a. v �> 3 0 s-. -z �\ a ° 3 •+ il �+ v rgi J, C s�". H z • a "• 00 n 0 � ww - -- N .5 'hrD y . .a ° U " ' V`� m .t G ¢ 3 Z w ' $ n 3 5 U c °"� ,�' °' c a Q ¢ y c °0,5 U o cr. O ° a o � C > a > al F 0 ^ 0. .. •J O O 2 U :O v, y r- ea C �... p �O ,. `� G Q s r-•+ rn ;•, 0 y b U y c 3 .5 _ .o •v ° as o 8 . c :..p^a., ' g as y w`-�, v i ^ oe A. > i+ t° g 4 ca M o 5 gb o cg ca .° n 4Ni Q• >,'c3•`a g cg Z mA 0O rz O - W C, .i O O c'� • N O N ,... /o c a C� .' t-1 ra.' Q v • >, a) as 00 z ° >, 0 `3 0 'o' c c ca E ,s, as •p . ° aCi Y3' 3 _ W N mA Z 0 2 .a 3 r.3 O co �} a as N . '^ g N• + F. C «. o Y3-' a ,.. r.: `8 C N U a '� �..aNm .'t w a a3 O Z as ❑ t' a� o ar a Z a is a b N •N C O O © Lt. O'y O a -MYNA S: 1.4 n pL .r ;L. u >+ O . "0 0 w oO 3 C ,, a) S. >O° .O >, U O g C E U -O g N - o ' O a p,C .~°. N F O F 11 .� LO 13 T LIP a y U u p S. ea g 8 0. U v i. O y C W w N ea �., w - Z W w O O a 4.4 ..a no a C '-� u a: o U a . O Q ca w c o N Nay = p C ., U o N O 4 y > H a3 O O O 0 d a3 y >, O c� a E > O «. -O a b y . o N N as 3 a)AZ a. Q; Q1 .,� z C.� f;r 0� a al W C `" rM+a E C O 8,2 N .L T. c> O �' c N b as 'O F. F Y. U'J - m= (U W U �l as ° c� K N U ❑❑ W ,: N A v N O as N O c� NO CC M1 . >, en• o i a >,a: > O N u p a.) cf1.. W w a C Ow . 1:' eOr C U ap' 3 O cLi ca q `3 O ❑ z " W�V ° tA im, a+ NF •e•4 enA t •. �°'— a •S a o M F 3 O 3 y X i cO� c a 05 ��+t�xW U Nn .N �..- • a, 3 ; N ° 4 p o as a N as o ° E v c p ..zaa W 5 ro .- N N N a vN, c° E u °� F. O p as Z 3 `— C a oo H O 3 0 3 c� r..+�- V} Q aa'. S ea ca 'd a) 0 N ° C .. a) '•' N .E 0 O0 N Ci) U c a) N C >, OY N q •sr �a! *. VJ `' >+ .Y rJ' _ N as as ca _ c O C O co W u • Fcn d o :° C13 t - UU 3- e W o a; a. n ° w $ •5 • � w 3r." .Y a a) Y a • W W Z v/} U a a� v] J <. r_ & ❑❑ O ❑❑ i s c'.„ g U 'C • 2 .8 N .o N as y :d VI cE2 yIII as o ,. pvvu. as r3 : `° 4. 34. W W 210 LNH2isJ d111 4 L o ca o0 o C U F A rz -1 a )I3'I'I3S © z v} U v) - o, c ;, CITY OF G • pry CITY HALL 33530 1st Way South (253) 661-4000 PO Box 9718 Federal Way, WA 98063-9718 December 9,2002 Mr. Chuck Heaton,P.E. BCE Engineers, Inc. 6021 — 12th Street East Tacoma, WA 98424 Re: Permit#00-103141-000-00-EN; TRESDEN PLACE 2920 S 298'h Street *Revised Streetlight Plan review* Dear Mr Heaton: The second review for the revised streetlight plan for Tresden Place submitted on November 22, 2002 has been completed. Please address the following comments with your resubmittal. Street lighting—(Sheet E1.1) 1. The distance between the proposed street light A3 and the A2 (south of S 298`h Street) is approximately 250 feet, which exceeds the maximum allowable distance for an arterial as in Std. Dwg. 3-38. Another street light on the north corner of S 298th Street would provide adequate lighting and a better uniformity ratio. A streetlight mounting height of 30 feet would be acceptable for all lights, due to obstruction from the overhead electric wires. 2. The uniformity ratio is 10.46,which is significantly higher than the 3:1 required, per Std. Dwg. 3- 38. Provide a uniformity ratio of 6:1 or less in the calculations. This may involve the use of 250 W. instead of 400 W. lamps along Military Road S to obtain the desired uniformity ratio, along with the addition of a street light on the north corner of S 298th Street. The average foot-candles along Military Road must be at least 1.5. 3. PSE and King County must also concur with locations of all davit arms and fixtures, which must be located at least 10 feet from the live power lines. If the streetlight mounting height of 30 feet is too close to the existing power lines,provide written documentation for verification. Street lighting—(Sheet El) 1. Provide stationing for all streetlight and service cabinet locations. Verify the correct stationing of the power pole(A3)where the light is to be hung. 2. The stationing for the light pole south of S 298th is incorrect. The stationing needs to coincide with the centerline of Military Road. 3. In the construction notes, there is no "8" found on the plans. Revise either the note or the plans for consistency. Mr. Chuck Heaton,P.E. BCE Engineers,Inc. Re: Permit#00-103141-000-00-EN Page 2 4. The two existing pole bases will need to be either removed or buried. Indicate this as a note on the plans. Please respond to all of these items and contact me at(253) 661-4132 if you have questions. Sincerely, ah f IA di t Kim Scattarella, P.E. Senior Engineering Plans Reviewer KS:dl Enclosures cc: Jim Femling,Development Services Manager • Tim Holderman,P.E.,Sound Engineering, 1019 Pacific Ave.,Tacoma,WA 98402 Pageantry Communities,25400—74th Avenue S,Kent,WA 98032 • Day File I:\csdc\docs\save\32458498098.doc E � d w al 1E Zr.) V) O r!1 Q U N 00 .r * a\ O\ d MXE. ea .•-.1 '-+ .-r .--• U U t ai ..fl Z vi O ( N c) �", 'cd I 0 N k at o VD A a.- I U U U U 0 g a o 0 A °' �cip , ' aU) 0 o.5n a) a) y '0 C C b * Zr) in O O 5, ai = .7 $W M M cc) M v) cUd a) •N ., 0 x a) `4, -.- ..o ,o ,.a a ) 4) 1,4 N U C) 0 3 .�, a) . �' cad � c`.) °� o - U maCy •or 6, !� .•—I ,--- .--4 .—, ,-4 0 0 C) VI] O V �, a"c•.0. c%i cYi cri •• �o `d o 0 Q. c� a3> v) °> Q •3 •cn �, 0 a; a. azV zs a> Q. •o 3 a� O a • CI kn v, oo �t '" o o 'b ` b a ao) = w • • o 0 0 0 0 �' Q" u. Ct 0 V b P. 'cl °o w E b � w b o ct U O �, c7 - — >, o >� o V1 O cd o -� a) a> Cf, 0 . a) o v O o (I-1 an ma) -O -d 0 o •ii3 o .4 Cl) vl v, V, V, ez Rl 0 a> loom -fp v ~ o.. ' o Noq ,�as p o fib -b i • o . n o .. > .� 5 71 .N U) .-. U) �n -07:1 M cc bn O bn O = _ e) Nv' O%:r a) O b0 N3 O Y H , tn CI vV ~ O • R - i v O a) d 1-11 ~ o bin r. O N c--1 G7 1--1 4 .-a < 4 r, •- O 0 O a .-°.a Z c,i c,i 4 vi r-• o0 il LAW OFFICES CORDON,THOMAS, HONEYWELL,MALANCA, PETERSON €d DAHEIM LU' TACOMA OFFICE SLAT ILE OFFICE 1 ,;,:I PACIFIC AVENUE. SUITE ewe, ONE UNION SQUARE POST OFFICE BOX 115/ GOO UNIV RSITY, iU1'r E: 2100 TACOMA, WAS,I-IINGTON 9i3401-117,7 SEATTLE, WASHINt3TON 96IOI-4165 12:331'.Cv20-63QQ.. (.TQ8I Cti76'-7300 FACSIMILE 15,'.531 620.6566 FACSIMILE (2061 6.76-7575 REPLY TO TACOMA OFFICE. WILLIAM T.LYNN ATTORNEY AT LAW DIREC'r t233) 620•Ca16 . 1206) 676 641.6 E MAIL lynnwegth-laW_com June 23, 2004 jUN C. 9 ,j14 i Robert J. Armstrong,P.E. Barghausen Consulting Engineers,Inc. 18215 —72nd Avenue S. Kent, WA 98032 RE: Hunter's Point Dear Rob: This is a follow-up on the easement research for the Hunter's Point project. The original deed dedicating the land for Military Road(recorded under King County Auditor's No. 3022384) includes the right to make necessary slopes on the abutting property. More specifically, a prior owner of Tract 1 of Secoma Suburban Tracts granted a"easement for slopes over a strip of.land 10 feet in width lying adjacent to and parallel with the westerly margin of a segment of Military Road." That slope easement was recorded under Auditor's No, 4819796, and I believe you have a copy of that. I am advised that the current owner of the property which needs to be modified to improve sight distance is Mr. Hector Gillis, Jr. Under the deed by which he received title, there was a specific exception for this slope easement. In light of this, the public should have an easement to make slopes on at least the 10 feet of area covered by the slope easement, Presuming that the legal descriptions match the area which needs to be modified for sight distance, the documents in question should provide the authority to make those improvements. Please feel free to call if you have further questions, Very truly yours, 1 [ William TL WTL:fto cc: Bryan White [1273300 vl] I\ "v 03/03/2003 13:34 FAX 206728722 F.A.T. _ Iii1004 I i 390766-1 LCs/Ms S "Me lai:l' ar,�.tl 'Mawre.eeewoto eon eroeeos's lest. • tea.eR....e4a6,...Y. W.APOO*MOOD ATPEouLSTOP TWEAMMICO Una Q INIUMINCII 02001Vdt IOW IM.Fi.IlitOain h6M••Ug WASISHIMMO vouPPA : 2i AN 8 30 wk.. 1 k..AceON O MOAN f ,D N,,. Nt. Nectar Gillis Jt. h;Cec:•s a(mTlOMa Kat C:Urirr.WAN .. ,t AX%'l' ,.,... 2672 south 296th street �, r '`/� 4 c..our.:. Maderaliar• W 96003 1 ,. . reer iewlr tlhrrsr �/Ood s �I THR caA,-tos NOM !. NNW. sad DOOM J. 1 . his Iota S t I w.rar.ee.lil.T%*d TO AND10/100/15 DOLWS AID Sill VALUARLN CONl1DSDATIOM lNrdr+• • .a..weerr NtC60 sallts. J0•.. a siasio see i t fa.Mimes entohd Poi WAY,okra rdr owes,d 1116 .s.MdW i.s...: I 4 Trot portion of the Natthssst 114 of des Southeast 1/4 of Sooties 4. IassshiP 21 March. sus 4 last. v.M.. io ties Cosstf. Wshioatos, i dsssrih 0 se fellers: i Desiriss at the Southeast eermet of Tact 1. u ofSias • as_MY*tat ersost/sd So Volume i9 of fiats. se pep 20. records Nsshilast ; theme North 6 1D 36" test 26.16 fast to the true { ,1s�' Mast!0 I'll" Nest. petalled via the Nast ', t lice oft it Trost . a di NaWO f7e10'K" Bast j /+ llss of said Tfioret 1. ■ disuses e! t lies of O thaws Nash doses r $ teat teaser or lees tosaid the clines is a poise uhioh boots swthssstsEif sloes arid watsriT . { i Uh Na10'!6" But free me true polecat hsst�sl. ei.*.a loath 07 0 16' Nest co the tree pinta hsiiseisi: } Situate is the Co ity of Bias. State of Yeshisstos. 1 j E for slops ss etrip 10 bat in siiieb Wog sdjsasst to sad Ls~te 'Military load, tecosded sir 1 Nisi/el dt�.the YesuslT Owes . . , 19Attor's file ■o. 6019796. 1 E f I,76 1 . ; Dodoes J. 1swe 1 STATE Of TM*SMOS Sri ! a STATE Or TiiAWr1a070r� • a �. ._.....__.� y ere....—._.:._—. _....... ,.d." "w.rM/.lM�tour 1ieira' Wi.wipM.a a a•i!tree r tell iePi s um;d*a; i *U I \. i DOlsf► JA.. -- WANK our awsziastrudi rli.....rwa.Nb Wife".i ..............._..... 1.w►pew..w ere i.,il.il.d a..e,lw Y eei �.._._._._...._............ .•..__........_.. ; rr.vwullr.Nr7.a/ie./.rR�' ee/-•---..._._._._...._ [last.t ...ie.d tee err peer l.r.w r w Ow................. .rA..Y.a rli......•.. ..._. Ned • _ ...... ... .s. , . Pepe W wrolns.R aid 4d. "�'et.._._•........_...the.r' _.. -•istiversal.yW+•._•w q".w Ne+1. • sell.... r' aaMAle.e.A.NAl t yr.w.r�WrY. IrM__'_mtier r.� I& 0.1 :e,Lei tlla ..b..dr �welM mil lWermt wd Opt the peel j • '31eei eMleh w*Is ass/Car:wwhe and d..�`I".rrr.Y»Nisi w�r awl,..e al. I our....en per Ned�.ld w Meer Lej : y.1aZG i...,arwwisl:our::drwe.efwirieewi w,an nrtk r our d sou • Issue•n•sal/et.— tt ......,__« .rlil.sM_- �._ _•__ • A.,..�eJe.P...H. h' 03/08/2003 10:27 FAX 0 002 03/00/03 THU OO: $ FAX 253 4 571 FATCO IJ1002 • dulness YMa. all .O/ZOaer lure tide...t•„�yi� oe July 1%.L.b••a bete sa L . Prod Aad.r..0 s sdaar.d T. Andersea bereiasattar Balled all GRAMS.d ties County, • • %.Mast s, b.r.dmsf:er aellea the MAIM what wow the MIME herein id the owner of teat osrtala Parcel of land demeriboi sr tallow, ta+qttu 'f at% 1 of Secoeo Suburban Tract: 100. the Vast 240 St. measured en the south line as rocoro.d in Vo1..39, Paso 20 .r fits Records or [Los County, Masi. • ' sad, • mums it nap bees resod rec washy lathe oosatrbatiaa sad 3nret m..at of RXL TA T MAD ( 3757 laving) • . nto mho ploper on The aa:d property of tb.minus!Or oats aM fills, as fo1loeal . ?e a aKrip of ]and ]0'ft. in width 17t1r adlecaet to mod peralla] with the tosstor]y a:.r¢in of Military load between tM''s. Ste. 67410 end Sta. '7+70 as surveyed br tint CnJnty lawny No. 10-21-44. 10i1, fgEApt>p, in coudgegatlen of thu prudes, the said%slue hereby ammo that et the eats .lapse may bonsai om his property as be rdabdole sot tarts, is oestermdty with ..r standard plane sad speedrdantssme for ads pmyo.00 eat to the some altose and purposes . as if tb. rigid.' hovels Qasted bed boom acquired bT oomdehrellom proe..diaie undo r lrum.ht Donate .taatt.. of tba hate o!1Amehladted. /T is MD ous ammo Alb MOOD by the perils.bares that this Fes neat has be.e slew to and accepted a, said booty subject to sad wPe*tbm fallaut*g eoeditie.a. to-vita If .a, part of end right or Lay plan bo abandoned or atoll cease to be u.wl or oc3atata.dd As a publlo.h1dtran by said Comedy, or therm/to%bora& Changed. the.es to sueh part .l1 ri#ta loader this easement shall thematt.r be nail mod void, asd wan y MAIM.portions or such tight of w shall attooseisealy revert to the al1T t, ,t ,aeooea.ore, • or assigns, without say arise being required. Of ���ylrI21�, legglt7, tb. .dL MAR VA ha. b.rwtto sip.d hi. :ua. thin /6 day 195.X. ." •.".34,� uitnea,•er) 7 .L, 4t./ -41 w---••P �/, C�......c. . - • • ,` =v., of lasbingtomoit Coyoty of Wog i b ' On tba Lh Jos of !t 295 bd%re so. a Notary 1e !a fur • Star o! Y�s�Liagtan sod pert maikr 91 2r �/�r.to se 1Mr to be tba i�or la sad who saw tba ad sai-o .d to mo tba sod male* ohm .a..As >141ie sad wmobimensirp m . for tie noes therms swtioaed. %Ifltds 4 Mad and Ott- % ii, ar sear t welttom rotary hablia is and for ti. • • • ,..a•.....c... •'-.at J. oAlt !am. `•.. '• ..o.;• ! • a....,,.,► amp . • c.4,. • our Boom A ab..aa G+.Aron n . . 5 • 03/06/2003 THU 10:21 ITX/RX NO 5117] JUN 41 9 200t ...., -,- Unott3 _______ • .t1898 08:43 FAX 208 728 72: F.A.T. Z002 . ..__--- ....----,..••••••"'"" -,i.',ki.11, '''T , •.--,i ' T "1- I • • •...r11IIP1141....,•._. . I .-•• ...- 1 , I I -.T - ' . ....; -•. . . .'' :. . .% Ar• VVVEr)::"...;.'‘:*•:•::a.1.-N:.>3. ,' ,',: • i • , I '1:, `7, , '' .' .. QUIT CLAIm .,1-1 . • -:•'• , ... .... .. . ....,,. ,. . . . :. . -.. . ..., , .....)...:1.....:-..... . ... .v i' • . • •c -11111' k.,,,_ 4.-. / P .• •• • - - ,.... Ga.. .4 -, .... -.,.. , , ...,1,,tj. •I.-P.7•,,,., LI ' '..-.:': .if''''r. EsT d.. • • • ....- ••• ..• • 7 •• " '• ! '''';' !......••7711,1. . • l ' 1 . • . ''-t,:t.•r---.•• 2 • '• .4.:..-.- ' .7.ii- • . •• / - .::: : ..;: .. .. :•:.. .."- ,,-:•...!..„..,..'.--_-•• , * ' ' Pr.LIAN,11.1 or.1...iittlii. iptilid1'FF. 4,,..-,.• i !,,.,-,•," M Ai'latlee '''''-- '''r•• '•:....' ieu-'.-- • ..-. •!'*''''"' " • •.. - • • . 0 '' • • ..""';,"7-.1.-C..i,'' i :."..;7:3 r/ )/,.__..1..4.......--1•1_,.L • 1"a"IT'' 1 •' - ' • '_„. ..:-....-•••--"'-''• A• • 1 JE...‘:1%111 I gli•'. •r''.s'-''• I . 1• -'liv.rviipari.lt,h-,..Ali...11•"'te."Y-e•l•P'ta‘r,, •7",:I,..,...., -'":"' .' .•-ivrei'eLle•"'"'•"'ll". - • . ' .- •: :..7 .."..'. 1••• %.,•1':••• ., , I •:.'e!.k.i't,-;;;;•••..F:•". :.!•!!-. .' ''.....• .....'...:..' . . .':.. SI111.:;4*&!4ilii.'"';;1.111'14.8•:,..".::Atti ' •-14..-.'....- .- 1 :.„-:,-, ,'; ..,.. •„...,.:.......... . :..- -..z...'. : ... lull.-... ._... • •- - ,„„,...''.i.,.. ,.-.14cf,.,..--,. i ' :',A •• -•....1.- - -...-•-- .-.. - 11141,e....1 iti Ow owsiopi - . 11,3 . . ..,,,.3,;.-,..-Fv.ir •4 . ; 1 ......A•; ;Iii-rg :lii Am. ,,i 40.1 ti .....n.,,.!........._„-.....- . ...... .. ... .. . .,,..‘ .0. • k z - is•%,,•,,otio a..: - ••.. .:•• • i••••-.= • 7•''. ..,". .":.••:.-..•'-**•.•.Z.;:-ZA,,U,:itget_liSmitaa Or • •• • ..-ilia go not iti laoto.00vlop,-;••••.• !I r.. a *trip D.' '.: •;" "• :I"••tft4',...' 'fee{ tbes:ear laaPolatt 11.'•• -. NiiitiNaNN'it 4 OS'AN} • .• ••.;,. 1.- :iv • -...1 0111;482$%' • . 1.0v-issorlaaa as fallealt -'" - . - • -,L ,Iti..., '7 ,* i -}.., •,.,. . -_,_ ai,,..,:i.....,,,,, .or 1.40‘g SS of•Igio-.5 '•••la% • .. On.0%1A. . • ,4 Ns: fit 34re i'4,420 flit"a6r.• • • • -e"Ali4 •••- ' • •,,. ' ''' . -.,. - ••.sout1010-tr t„.' ,..1.14 .;• -7104'trz.io.az.400-1r, 2!4.t•S! 11°F,',19 - • ' ••• •-•Sifo' , .' ••' -15, t •gotOrttiraer-"' ••'-'----- ..A.-1 w efiegz.of roe.;:4'aro-iliao!.-or.T03.1.tai#1t. . ,..•r.. • -- , ••• "...4.•••- • "•to•too.loft•Itviltit'••••r=-14- of • •e." -a' 136 foo443-.004(•• . ..,,...i vs„,•1,j0 ..•.:•-‘7", •‘ 1,4911 e;lei tr4:01.1“aa• we'reut . ••:•'.-"".• ;. ••:- •. • .1.. r''•••••.. ,2,14V' '914,,athvost•writer:. • . . ..• . - •.•. ..-23_.......-4,,. ..,.........„..r„.. ,.,...1 _ii :.i•••";...;',":1' ...4••'. :''..! .e,'•:‘•••.-*'' '.- COlit .ti-a:ert, Nor. br 1..." • .....L.'.• ., .. . .. • •.. .•r..1:Y.' .,... - e...'4. .. ::; taatill(1-7. . .. . ... ... . ,•r, • • 1144,401,s.44-a•iiia-iev-----•--7-:-.. ,. . . -%••• iv. .. ',f2•616-11.. , . • : - . ..,. ::" ..:'..,•', .* • • . . •. '• :. • • ..'.'•.'• •;.,,-7,!..•..4.,-11.:::-....,''•,:•••:', :,....., ...,• • • '..1 ' •-. • ' .,.•...: .., •'7 '•;.e."•-•f!,-..-••,•.,..'... •••• . .- :-.• ••.; - "•i:••• ,-',•• ,. ..t.,:•4•, ::41_2, 4..• ,..s•---= a •,•....... .„., 7•:.• • Y'V.-..... .....'•'' '''•-•!'-- .. ...••••••...-7-• '''-'7....,- *":,''',..7i'"-Ffrili' 'VC,•••'..... : •.-.'1,1.• - •--;',. •. /- ...:/.',•••ria.;. •••••4, fritt.:.;),4,..' . • ---- -:- .3-•-•---• ..clItr-c- '. • ;.....••, ',.:. ..- •! .7. •'••C_-!,.1.:•••VMX:V4.•,;0;•%4 ' -.:•:. ...;. '-,--.t. -- _. -, • -",...••••••--„:, •-....-_...,••..., -1.--, - - ''•• • ' :•1":-.•:•-•.' -•:-•..;,•-•4.--/....-.•••.. ,..i....,!..,sgi: ., -..-- .. . .. • la S. Oe. '"..1 ..4'.:;7:••• -•."•• ....••••.:,'"...••'to"••••,1;0. 1:'...,..• ,,, ''''''' '-`5•• - - .. .Mr1 A Vo, -A..-•...-', •;..,1',. -,...4-ts• -t--'•'--r";- - . • ..: . .. -'" ......?•1"..,..-iw.L. r1•;,a f... • •"• , ...:. • ••••r; • 6.: :-4 4.- • • ••• "• *.• • •• •71.; •'.• ';',•z.•co:• ' *-. ; :• , • • • - - •, • . . .; -.41 -SAI.:* ..\. ...: _ • .1: ..• ••••,t.-1 .. .• .. •-•. • '.*; -*• :- •,•••''. ""*".".' ' . •- ' ,-;. •'•••• . •.- ‘•... l•..'-. .. ••.' . -:.'• ';.;7-41.''Irr 7.".7'•...'-''• ... ..ii'''''. .... •-"... .-.. • -• • ...- . - - .... ' ..:. ..-„,..AA.....;;,/.. •' "...."1;;.•1 ; • t+.:...it .."! , • '-1.,..A.:....0.1 •-• . .. • .. .. . .' . • - .-. •'. .,, .:. ,.•. ....,•;,41,,i• ,_-,,, j, y•:.1 . ri,,.. :- •••,-, . •- ' . .-• - • • • -• . ..--- -.. i. ..,, ..:L5 .--....,,.yvi :,.m.1- ..•,..7;, .. .. . .._ .-7.i•..i [••••• ',.......0,,A-.,`,.''•'., • -I. 4 i, •' :: 1 0 •1 - j et Mtn Woke..11,11revotitry b ot I.. . . -.....- .11ige. hiliiiiiiitilillia-vid•yntirk.coviana ..%.•titli r170:3"1"1 •A•111:4. '4111.147414e.r4... 'i.ti .'l.l''';''''_4::: eft .. Al • ., . ,.. vied 1.6a utikok;itir.tabit•nottk•ant-• --,.. . , I• --- .„ . . ., .. •• . •or.ia, Tim tra ..- - .........:- •••. .1 •. - .- .„...-17.74cVS0. •...,• '' •• ' ' . I. N a 4.j.1_ ,Ialtion‘DAtietiai.likternilog. t..!Stiil le re YIA- . ,..,, ,........ . 4.......,-• •!. .,..:1,1•.:. . t t. 4 ' •-.1 -'' • .•• •,:•.-. ct:-•--' • 10'''''' 1 • --,.,, t•T i ' •• 1.1 '''' '; • ' .- • ''S1.111(1.0t Wo..41.11 iptr.:•••....",v....:. .•••.?.•••.::• ... - .' ' .1. -- r • Li ''I 1:-•;%:•'''''''''''''''''''-"- '-, • - •' ;' -Fif!'. ....',...!i'..,',..e401.:.i..•••!ii.e -*-..7. ;,1 :-",, -1••• .7'••• : - - ...,..A.•/c.1.I.••. ../....- I • . .'•-•••42:'-'. '.- • • ..-- .....1 )V1,•.' - ,i r I ?. .., l'' . ' '- -• '....' . . A' •.: •-7.t. •- • - ' 47'.17-.1.:* ' ' i"r•-19'.b Jr.••• I LI! - • ,..-:.1 .141..!etJt-....-..•., 4: ..• .-az.. . .• • ..... . _ .. --, .t.i. ,.....lAr.....-•- - ..... ........ ................_:Z.,_._ ........-,= i -.:•+.-...40A.. '.''''' .- '''''.'. --. -- "--.2 -`' :•.--------='---------7---- - --2-..:_----......-........ine.•••••.'!-- ..-•-••••••• •••. ••••••••• -- -''"•-• -, •".. .1:.; ----'----- L -' 1:7- 7-47' •. •.- .::: ! !...-ts -4•,-;,•;"4 ...-1! ---- -- ---- . . . . ....._.__.--. ..._ . . • ,,,, J . L jr it.iti4 • SOUND ENGINEERING, INC• • civil engineers•land planners Our File No.: 99213.10 AUG 15 2002 August 12, 2002 Kim Scattarella City of Federal Way 33530 1st Way South Federal Way, WA 98003-6221 Project: Hunter's Glen Plat Permit No.: 00-103141 Subject: Military Road & 298th site distance issue Dear Kim: I am sending this letter to address a couple of issues you raised in your recent emails and also provide you with our site distance findings recently conducted by Center Pointe Surveying regarding site distance measurements for entering and stopping site distance associated with the above referenced project and the Military Road frontage improvements. To review, the sight distance analysis performed by Center Pointe Surveying involved the intersection of South 298th Street and Military Road South. The sight distance analysis measured post-construction distances as well as distances prior to Military Road re-construction. The analysis measured both stopping site distance and entering site distance utilizing AASHTO 2001 and the 1993 King County Road standards. The analysis looked north with a vehicle sitting on the west leg of the Military Road South/South 298th intersection, facing east. Setback distances from the Military Road South fog line varied depending on the site analysis criteria used. The results are as follows: *Before Hunter's Glen development AASHTO 2001 entering sight distance: measured 339', required 441' 1993 King County entering sight distance: measured 438', required 555' AASHTO 2001 stopping sight distance: measured 546', required 305' 1993 King County stopping sight distance: not measured, required 325' *Current Conditions AASHTO 2001 entering sight distance: measured 212', required 441' 1993 King County entering sight distance: measured 306', required 555' SE 1 1019 Pacific Avenue,Suite 906 Tacoma,WA 98402•(253)573-0040•FAX(253)573-0142 August 12,2002 Page 2 AASHTO 2001 stopping sight distance: measured 463', required 305' 1993 King County stopping sight distance: measured 439', required 325' *The required sight distance was based on a design speed of 40 mph. Please note that this design speed was utilized as you directed in your June 4, 2002 email (enclosed for reference). In addition, adjustment for lane width or grade was not considered in the analysis. As you can see, the field data clearly shows a reduction in entering site distance. The reduction is on the order of±130 feet (under both of the analysis scenario's). With that being said, I feel that it is extremely important to note that the field work also found that entering site distance was well below standards prior to any development work associated with the project. In addition, the field work found that stopping site distance exceeds the standards (under either scenario)before and after construction. As a result, although a reduction in stopping sight distance did occur, it is still well above minimum requirements established by AASHTO and King County. As a result, I would like to point out that the reduction in sight distance, in our opinion, is a result of a combination of factors, first of which is, the construction of the keystone wall along the west side of Military Road South. It is important to note that our approved plan set did not include the construction of any type of wall system within this area. It is my understanding that, without the knowledge of Sound Engineering,Inc, the site contractor was directed by the City's field inspector, Mr. Jim Pryal, to construct this wall. The originally approved road improvement plans required a 1:1-1/2 re-grade of the existing slope to allow for adequate grade transition within the city's R/W due to the road widening activities. It is our opinion that, had the work been constructed per plan, the reduction in site distance would have been less pronounced and/or possibly no reduction at all. The surveyors have indicated that it is the wall height, existing overgrown vegetation and the existing un-regraded slope that currently limits the entering sight distance. I believe that, previously, city staff recognized the wall was in fact a problem, as one of the past "punch list items" required removal of the first layer of brick off the top of the wall system. I believe this was done with the hopes that entering site distance would be improved. Again, without the knowledge of Sound Engineering, Inc. This brings us to your email dated June 14, 2002, (enclosed for reference) in which you stated, "the entering/intersection sight distance will need to be improved to as close to the required value as possible." To begin, we have evaluated a couple of different options to return the entering sight distance to the original entering sight distance of 339' for AASHTO 2001. It is our opinion, that, because this is health/safety issue, the 2001 AASHTO requirements should take precedence. Lastly, I want to clarify that it is not the responsibility of the Hunter's Glen ownership group to fix a sight distance problem that existed prior to the Hunter's Glen development. In other words, Hunter's Glen is not responsible for improving the entering sight distance to AASHTO or King County standards but only to the pre-development entering sight distance conditions SE 2 August 12,2002 Page 3 if it is deemed that the originally approved plans did not return the entering site distance to the pre-existing condition. However, we are amicable to coordinating the sight distance improvements with the City of Federal Way if the City would like to pursue a joint effort in correcting the substandard condition.It is my opinion, that re-contouring of the existing slope in �. conjunction with further reduction of wall height could improve the site distance substantially. I ei< a J g P also believe that, due to the existing Military Road South vertical and horizontal alignment, that achieving minimum entering sight distance requirements will be extremely difficult as best. Pis a result, I would ask that the city reduce the posted speed within this corridor to better meet th6 entering site distance available$ Ne1' (ce New Please call me if you have further questions or comments regarding this issue. Our team looks forward to working with you and city staff on a solution that is in the best interest of the health, safety and welfare of the public. qrr Sincerely, 5}zoo 4.75 `.z,, %u,( G Timothy D. Holderman, P.E. Principal enclosures cc: Bryan White, Pageantry Communities F:\Ie tters\2002\99213.Ki mScattare l la.08.12.02.doc SE 3 • Leah Dunsdon From: Kim Scattarella [Kim.Scattarella@ci.federal-way.wa.us] Sent: Tuesday, June 04, 2002 8:38 AM To: Leah@SoundEnglnc.com; TimH@SoundEnglnc.com Subject: Tresden Place - Sight Distance Information (resent) Leah, Sight distance information is classified as a Life/Safety issue. Therefore, we would like the information obtained by Centre Point Surveying, prior to final plat for Tresden Place. The LUTC meeting has been scheduled for June 3 and it is scheduled to go before City Council on June 18. For our information, was the sight distance measurement taken after the layer of bricks was removed from the keystone block wall ? If not, the sight distance has llikely improved since then and may warrant another analysis. Does the sight distance meet stopping sight distance requirements, which are 305' for 40 mph, per AASHTO ? If you have any questions or concerns, please call. Note: The correct date of the on-site meeting was May 3, 2002, rather than May 10, 2002 which was previously stated. Kim Scattarella, PE Senior Engineering Plans Reviewer City of Federal Way ph. 253-661-4132 fax. 253-661-4129 1 Page 1of1 Leah Dunsdon From: Kim Scattarella [Kim.Scattarella@ci.federal-way.wa.us] Sent: Friday,June 14, 2002 10:19 AM To: Leah@ SoundEnglnc.com; TimH@SoundEnglnc.com Cc: Jim Femling; Ken Miller; Rick Perez; BryanW@PageantryNW.com Subject: Tresden Place Sight Distance Analysis Hi Tim, Leah; Thanks for your sight distance analysis. Your analysis showed the stopping and intersection sight distances, but did not list the required distances for these parameters. Based on this analysis, the stopping sight distances meet both AASHTO and King County Road Standard (KCRS) requirements. However, entering (KCRS) and intersection (AASHTO) sight distances do not meet the minimum criteria. You measured the entering sight distance, per KCRS to be 306' vs. the required 555'. You measured the AASHTO intersection sight distance for a left turn to be 212', vs. 466' required. The entering/intersection sight distance will need to be improved to as close to the required value as possible. Please provide a plan that will reduce the obstruction by the bank, but preserve the keystone block wall along the west side of Military Road. This mitigation will serve as completion of the related item on Jim Pryal's punch list. Call if you have questions. Kim Scattarella, PE Senior Engineering Plans Reviewer City of Federal Way ph. 253-661-4132 fax. 253-661-4129 8/12/2002 0111C)‘-Piqg fat", de- k>m, Jim, TACOMA OFFICE RILL 6021 12th Street East, Suite 200 ENGINEERS,INC. Tacoma,Washington 98424 TACOMA • SEATTLE • OLYMPIA I=; . Phone 922 0896 SCP 1 9 2002 September 16, 2002 City of Federal Way Department of Public Works 33530 First Way South Federal Way, WA 98063 Attn: Ken Miller Re: Tresden Place Street Lighting Dear Mr. Miller, Bryan White with Pageantry Communities of Washington asked that I send you a letter regarding exchanging the three poles on Military Road South with three others in the development due to a conflict with the power lines. This should not be a problem as long as the pole heads are switched as well. The fixture heads on Military Road South are 400 watts HPS, and the development fixture heads are 100 watts HPS, and need to remain as such to keep the lighting level as designed and in compliance with the City of Federal Way requirements. Please feel free to call with any questions or concerns. Sincerely, BCE ENGINEERS, INC. ix- Charles A. Heaton, P.E. Principal cc: Bryan White, Jim Femling, Kim Scattarella M:\SPECS\Spec Archive\2000\200-176\Letter-Tresden Place Street Lighting.doc CITY OF 4110 CITY HALL 33530 1st Way South (253) 661-4000 PO Box 9718 Federal Way, WA 98063-9718 July 29,2002 Ms. Leah Dundson Sound Engineering 1019 Pacific Avenue Tacoma,WA 98402 RE: Permit#00-103141-000-00-EN; TRESDEN PLACE 2920 S 298th Street **As-Built Plan Review** Dear Ms.Dundson: The second review for the as-built plans submitted on July 17, 2002 has been completed. Please address the following comments with your resubmittal of two sets of as-built prints. Site Surfacing&Dimensioning Plan/Grading and Pond Plan(sheets C-1 and C-4) 1. As-builts for Streetlights are required by the City as an element of the punch list. Please submit these as-builts to the City after the location of streetlights along Military Road has been finalized. Storm Drain and Road Plan&Profile(sheets C-5 and C-6) 2. Please correct the rim elevation at CB #12 to read; 467.18'. The distances from the rim to inverts consistently indicated this elevation. 3. Indicate the location of the 6" active perf. Pipe from behind the rockery to CB #1(shown in red on sheet C5) 4. Make the catch basins symbols larger on these drawings. 5. Indicate the invert elevation at the outlet to the riprap pad downstream from CB #1 on sheets C6 and C7.1. 6. Indicate the stationing from beginning to end and show the keystone block wall on the south side of S 298th Street. Also provide top and bottom of wall elevations. Reference the change order that was approved by the City to show this feature. 7. Also indicate the stationing from beginning to end and show the extent of the keystone block wall on the west side of Military Road, south of S 298th Street on Sheets C6 and C7. 8. Please label all streets in the drawings on Sheet C6,C7 and C7.1. Ms.Leah Dundson SoundEngineering Permit#00-103141-000-00-EN Page#2 Military Road Improvements—Storm and Striping Plan &Profile(sheets C7& C7.1) 9. On sheet C7.1, provide as-built invert elevations at culverts for the three circled locations along the east side of Military Road(this is a repeat comment). General Notes and Details(Sheets C8 and C9) 10. For details A and B, the pond sections on sheet C9,revise the wetpond elevation(452.12')to agree with your supplemental calculations. In addition to the above comments,the Sight Distance Analysis with proposed mitigation measures along the west side Military Road, south of S 298th is also required prior to completion of the punch list and release of performance bond. Please respond to all of these items and contact me at(253)661-4132 if you have.questions. Sincerely, ` - 4& , Kim Scattarella,P.E. Senior Engineering Plans Reviewer KS:tm cc: Jim Femling,Development Services Manager Pageantry Communities,25400—74d'Avenue S,Kent,WA 98032 Project File/KS Day File I:\csdc\docs\save\2 1 05 3 1 26007.doc • SOUND ENGINEERING, I N C• • civil engineers•land planners RESUBMITTED JUL 1 7 2002 Letter of Transmittal Project No. 99213.10 TO: Kim Scatterella Project Name: Tresden Place City of Federal Way Subdivision 33530 - 1st Way South Regarding: As-builts-2"d Federal Way, WA 98003 submittal Date: 7.16.02 WE ARE SENDING: 4pU 00l 0 31 LH NO. COPIES DATE NO. DESCRIPTION 1 7.16 C1, C4- C9, As-builts C7.1 1 7.16 Pond Volume Calculations THESE ARE TRANSMITTED: FOR REVIEW AND APPROVAL Kim- The enclosed as-builts are for your review and approval. Tim's signature will be on the final as-builts. Please call if you have any questions. Thank you, Leah Dundson Senior Design Engineer C: FILE 1019 Pacific Avenue,Suite 906•Tacoma,WA 98402•(253)573-0040•FAX(253)573-0142 F:\FORMS\City of Federal Way\Scatterell.letterof.doc • S O 1I1\► ENGINEERIN ; �; .7 civil engineers •land planners Project R-, todoiy► With/To Page 1 of Project No. 99 �3 to Address ESU�i�! I TED Fax# �`�'�'�- Subject PDX" "h J U L 1 7 2002 #Pages Faxed By Liii! Copies to Date S#,' /V.2 tf 3��orry, PQVt 'C ...Ii//. L/S2.37 i Oad/ /45b416. 'u.s. !..l�' a/o rho ma fir O// of refeml ft./a V cr.f ct,.r p( , -r, t. L/5.' 1a =/Oyr ztidtr surf a pow 4/5 s+ � 7asf •15.,ys .fa 5&r-LL 1/5.a -Zr Sfr Lf Sz/G0 9 57Y S T 17z/y cc v5-9./.2 Li5606 / 5-00 5-re / 2? c{ ySSDa 13669 s-F End 1 0 1..3713 sf _ 164/ 4-r zi 59`0.1 /y 3 96 sf s � cr 7/. > 3 3 5 of De-f .-6i7 /( ZetePerno.e j,5,/3 44i 7 ! i F6..6 s� Li4'Z'dd 3 395 0 39 cf YSooa G4/0 1779 cf L/ A00 `7C.7 l 47q ? / .2159 � 3 7r7c- Z�9�s9.c.f a 44,a4r, If the above does not meet with your understanding, please contact SEI in writing within 7 days. Thank you. 1019 PACIFIC AVE., SUITE 906,TACOMA,WA 98402 • (253) 573-0040 • FAX(253)573-0142 E-MAIL: sound@soundenginc.com 1 cO 000000 (5" AVY,ww O ;www; \ =wwwii \,a 5ywwwUU �X ow`nww -oss N \ w v < -1; f i o h_' \\ \ . m v o � \ \ \ -4 \ d \ , IT \ 05- \ \ 4 , s ci \ ` Z/ CA 4:::4 \ -4T ci \ I c-1- i�� 1 6 4 s r _P - CITY OF = • '� Fry CITY HALL 33530 1st Way South (253) 661-4000 PO Box 9718 Federal Way, WA 98063-9718 January 31, 2003 Brian White Pageantry Communities of Washington 25400 74th Avenue S Kent, WA 98032 Re: Permit#02-101104-000-00-SU; TRESDEN PLACE 2920 S 298'h Street, Dear Mr. White: As you are aware the CITY OF FEDERAL WAY has been working with Pageantry Homes to complete - unfinished required improvements associated with the Tresden Place Final Plat. These improvements include interior sidewalks, street lighting on Military Road, sight distance at S 298`L and Military Road., and removal of the gravel cone from the detention pond. City code requires that the applicant file a performance bond for all improvements not complete at final plat, and installation of such improvements be finished within six months. To date none of the items listed above have been finished. In order to avoid action by the City against your bond,please provide a schedule in writing as to when the above items will be complete. Your schedule for completion must be received on or before February 5, 2003. If you have any questions,please call me at(253) 661-4196. Sincerely Qt"‘C(F-N'emlin g Development Services Manager • JF:dl cc: Kim Scattarella,Senior Engineering Plans Reviewer Will Parker,Construction Inspector Project File/JF Day File L:\CSDC\DOCS\SA V E\5220233055.DOC CITY OF FriliVCITY HALL 33530 1st Way South (253) 661-4000 PO Box 9718 Federal Way, WA 98063-9718 June 11, 2002 Mr. Tim Holderman, P.E. Sound Engineering Inc. 1019 Pacific Avenue Tacoma, WA 98402 RE: Permit#00-103141-000-00-EN; TRESDEN PLACE 2920 S 298th St Dear Mr. Holderman: The as-built plans submitted on May 23, 2002 have been reviewed. As-built plans are an element of the punch list, which affect the completion and release of performance bond for this project. Please address the following comments with your resubmittal of two sets of as-built prints. Site Surfacing & Dimensioning Plan/Grading and Pond Plan (sheets C-1 and C-4) 1. Please refer to attached as-builts from Centre Point Surveying. 2. On sheet C4, indicate the finished floor elevation for Lot 47. 3. Provide as-built pond volume and backup data for storage volume for sheet C4, (see also Sheet C9). Storm Drain and Road Plan & Profile(sheets C-5 and C-6) 1. Storm line locations on both sheets are confusing. Use a heavier line with flow direction arrows to indicate where they are located. 2. Some as-built numbers (CB as-built elevations) are difficult to read in the vertical profiles. The plan view data for CB #15 is difficult to read. Make these numbers more legible. 3. Verify the invert elevations for CB #2, the rim elevation for CB #12 and the correct invert elevation for the end section, based on the Centre Point as-builts that are enclosed. 4. Show the correct location of the active 6" perf pipe from the drain behind the rockery that connects to CB #1. Also indicate the invert elevation of this pipe. Mr.Tim Holderman,P.E. Sound Engineering,Inc. Permit#00-103141-000-00-EN;TRESDEN PLACE Page#2 5. Label CB's #7, #8 and #9 on the S. 296th Street portion of sheet C5 and reference them to the sheet where the as-built data is located. 6. Ground elevations near the outlet and overflow control structure have been raised by additional fill. Indicate this on the revised contours in this region on sheets C5, C7 and C7.1. 7. Indicate the location of the keystone block wall on the south side of S. 298th and the spot Top and Base of wall elevations on sheet C6 from a previously approved change order. 8. Indicate additional roof drain lines for lots 43-47, shown on the attached change order —attached to sheet C6. Military Road Improvements—Storm and Striping Plan & Profile (sheets C7 & C7.1) 1. CB #1 shows a 6" pipe invert, but believe that this pipe should be 6" perf pipe, that comes from behind the rockery. 2. On the east side of Military Road at S 298th, there is DI pipe indicated here. Show the length, pipe diameter and slope. Also indicate this pipe beginning at CB #22 and ending at CB #1. 3. The as-built data for CB's #21 and #22 are difficult to read. Please make these numbers more legible. Indicate CB #21 on the vertical profile below on sheet C7. 4. According to the original as-built data, the rim elevation of CB #20 should be 459.56'. Please also verify all invert elevations for CB #20 on the plan and profiles on sheet C7. 5. Indicate the length, pipe diameter and slope for the pipe from CB #21 to CB #20, along the west side of Military Road. Also indicate the invert elevation of this pipe at CB #20. 6. Indicate the correct cross slope (3-5%) across Military Road on Detail #2 on sheet C7, Detail #2 and #3 on sheet C7.1 and Detail #10 on sheet C.B. Also provide a range of widths for the paved shoulder portion of the road that was widened on both sides. 7. On sheet C7.1, provide as-built invert elevations at culverts for the three circled locations along the east side of Military Road. l:\csdc\docs\save\16726849080.doc Mr.Tim Holderman,P.E. Sound Engineering,Inc. Permit#00-103141-000-00-EN;TRESDEN PLACE Page#3 General Notes and Details (Sheets C8 and C9) 1. For detail #4, sheet C8, verify the elevations and label as"Outlet Control Structure". 2. The 10-year storm and pond bottom elevations have changed. Provide as-built volume and back-up calculations (see also Sheet C4). 3. Provide as-built elevations at the inlet and outlet of the coalescing plate oil/water separator in Detail#4, Sheet C9. Also indicate these elevations on sheet C7. Please contact me at (253) 661-4132 if you have questions. Sincerely, IlLIA1,1 1 Kim Scattarella,P.E. Senior Engineering Plans Reviewer KS:tm cc: Jim Femling,Development Services Manager Pageantry Communities,25400—74th Avenue S,Kent,WA 98032 Project File/KS Day File l:\csdc\docs\save\16726849080.doc bp(0-- .• . , -, : - . W o . , . ' �. ii,. ! .psi^'a ,:! ` pj "` ,/ 3 b,'.^£ 5 K SttE p'ccpp'k p,',, r bi"" R" fr 'i ... 4,/, ':i'4:9:4014'-41r*,, ...‘,...:-4:-.''.---.--:, I..41:H„3„1,... , ,ti ,4,,,,..;,...,,.... ..„.. :i0f `"'- "ms ...> ;,;> ✓ � s '^r, a : P ' / y --„ 474,- hy,4y / y, , ' ": < ' /�; %� n,s,.,�, E.�. �,v,», Y ' %;r"„�, ?s � .ma'" ajd"„t^; .-.:, 'j�;:;, : , ::, . r e titir. ,, ,,, „'rU { �, , .� r... v. ,r s._.;;'">'r'.o/„ _ ',p'at;, er f°--. :^.; • `Y,c,, f,r,, ;$4-'.prm";,rp.jii'.,,,., �* `rp.V'a 'ii=, ;`,fat;k;e ;i„"�;y;,,9r.�,r. ;;.'v _ ''. s,m,,, .t�.=,:,.• w.oit.'.,- ;;;i`;a' us'cv�"`"rl gam:•`,',�sr -�' / 4,, �y Y�"� .P•• � vW�.,s�� '�'n�=r r •;� ' > � 3� ��sY2>' 4"r v.�., a -:..5's'¢' ." fittint; .as�sY %,ire 'r¢.,�A,.;� 'r i,v '� `. M "54"' '','" vv' �Y, ,.' &'�' ' � �,'.,..w.;:. °`ate. N" �: '-" „ e $5 "�• .��Po�;`r r'Q 3 tl AJ.r F6 °' F��,.'�rlif,.;'�a �,;'�",, . : �',,,, a,s r5'.x,"• ;, • 'es . 'irk; •;.' •. ,4,"' t ,,,, t%,' r s m',„,„s ems' "-, '� :%. ,.,,' '.<,; , }'_' ,h': '`�.,y:,.=�:r_; -. %, /, .r.,,•-4 • . ', sin r,,=:,ti , "„+tea; �� y„ , . �,,,_.. "�, � ., ,,r�ir,.c;, „a,�.* � M`;,"; �� �.,� ' .�,"a;', ;y,;s;`"s "t '�r- "'��,�a:."�,�,,'a°�,',e{'�,,,-r^„C: �, r��wr r „�aM es' �'�j • , 'S 3 j,-`,..v .'.:�,;,, ,4.«., o �%*,.-: g Ylvi.; -.k' ,;i„+, ;: e "'xr� �° Th So ,�f1r.S.k''�'vr�P',.,;; - ,, 3 f.� ..3?,rr'% � ,�y,.'zx�, ,ry,;,°r - s ,'Y"4"'', 7 We.. �.� `•Y�t%b'af ,,,,,a ,,,,,,:, ,,'pt';,,,.v :9 ,,, , v:'Y,c'tmr-sfx.r• -;;'5 `'.%.s,' raA civ.�, ',•,e,, *,,?1*-,*"''s?s',,`", %;'r` ,`:A"; .�.; ,,am' '•h,'*' rt?, ,,,,', li /„N,'%:`,' vi rft � anti, 1' . ;;," '`,!,V1:i,,,,, ,',`,4a ry'rr'Hi"hf"'„ ,;:f'%y£"" ( " r; $�g(•s,&`'„rr,';'„� j &3 4- say Ili-9-Sa r,,c2t„ L" ' o CITY OF DRAFT • >\ CITY HALL 33530 1st Way South (253) 661-4000 PO Box 9718 Federal Way, WA 98063-9718 May 13, 2002 • Brian White Pageantry Communities 25400 74`h Avenue South Kent, WA 98032 Re: Permit#00-103141-000-00-EN; TRESDEN PLACE 2920 S 298th Street; Final Punch List Dear Mr. White: An inspection of site work was recently performed on the subject project. Based on that inspection, the attached punch list of deficiencies was prepared. Please note, this is an official punch list and is valid for 30 days from the date of this letter. Any additions or deletions to the punch list, or extension of the 30-day limit, must be approved by the Public Works Department representative or inspector. Deviations from this policy must be reported to Ken Miller, Deputy Public Works Director, at(253) 661-4136. Upon completion of the attached punch list items, the following non-construction related requirements must also be met prior to the release of any bond quantities: • As covered in the preconstruction conference, reproducible mylar (without mack-tack), or photographic "shot" copies of record drawings (as constructed with all appropriate design changes), shall be provided to the City. • All administrative and inspection fees shall be paid in full, with a check made payable to the City of Federal Way. As of May 15, 2002, the inspection fee is $15,758.78. Additional fees related to inspecting items on the attached punch list and review of as-built plans, must also be paid. A Maintenance Bond in the amount of 30% of the cost of replacing the materials covered by the Performance Bond shall be posted prior to the release of the Performance Bond. As an option, the existing bond or Assignment of Funds can be reduced by 70% in value to the amount required. This bond or assignment will be kept for a two-year maintenance period from the time of final project acceptance. Prior to the end of this maintenance period, the City xvill conduct an inspection(s) to note any defects in workmanship, function, or materials, which must be repaired prior to the City's final acceptance of the facility. Please contact me at(253) 661-4128 after completion of all items on the attached punch list. A follow-up inspection will then be held with your representative. if all deficiencies have been corrected, inspection ! Re: Permit #00-103/41-000-00-EN: Ire.cden Place Page 2 fees paid, and as-builts approved, partial release of your bond or assignment of funds can be processed. Please contact me at the above number should you have any questions regarding this matter. Sincerely, Jim Pryal Public Works Inspector JP:dl Enclosure cc: David Lonyo,S&W Utility Contractors,Inc.,9416 S Front Street,Tacoma,WA 98409 Jim Femling,Development Services Manager • Project File(JP) Day File 1:\csdc\docs\save\14550233037.doc Re: Permit #00-I03/41-000-00-EN; Tresden Place Page 3 Final Punch List Permit #00-103141-000-00-EN TRESDEN PLACE 2920 S 298th Street May 13, 2002 LOCATION/DESCRIPTION WORK TO BE PERFORMED STORM(on site) CB 1 Clean the catch. As-built the new drain pipe. CB 2 Clean the catch. Re-grout under the outlet pipe. Asphalt patch is high and needs to be replaced. Change the rectangular solid lid to a round locking lid. Overflow Control Clean the catch. Remove the conduit, rocks and other Structure debris from the pipes. Extend the ladder to within two feet of the bottom. Secure the hanging ladder. Grout up the old step holes. Provide galvanized bolts to secure the debris cage. Backfill the structure to grade and provide padlock per the City's keying requirements. Outlet Control Clean the catch. Pump down to measure the orifice sizes in Structure the control structure. Provide two straps. Provide ladder to within two feet of the bottom. Secure the hanging ladder. Grout up the old step holes. Provide a hand hold step. Provide a row of adjustment bricks and re-grout. Backfill the frame and lid to grade. Provide stainless steel locking bolts, maximum 1 '/2 inch length after final acceptance. Storm Pond/Storm Pump down and clean the bottom of all silt and other Tract A construction debris. As-built the pond to verify size and volume. Provide additional rip-rap at the inlet pipe. Remove the gravel cone riser after the site is completely stabilized. Obtain permission from City inspector before removing. Provide gravel access road. Provide concrete driveway off of South 296`h Street. Re-Hydro-seed all sides of the berm around the pond. Remove all rocks and silt fence which is partially buried. Complete the landscaping. Chink all voids in rockery wall. Provide additional chain link fence between rockery wall and the fencepost near the entrance. Provide padlock for the gate per the City's keying requirements. Contact the City inspector for padlock supplier. Tight line exposed rockery wall drains to pond armor outfalls. Re: Permit #00-103141-000-00-EN.; Tresden Place Page 4 CB 4 Grate is not fully located in the gutter. Access steps not usable or safe to enter. Provide acceptable access ladder. Clean the catch. Top section is weeping. Re-grout the section. CB 5 Re-grout under the pipe and lot drain. Outlet pipe has settled approximately 50%of the diameter of the pipe. Re- . lay the pipe between CB 5 and CB 6. CB 6 Re-grout under pipe. Plug old rockery drain. CB 7 Re-grout under the N-12 pipe. Provide a hand hold step. Secure the hanging ladder. Inlet pipe from CB 8 has several low spots and standing water. CB 8 Clean the catch. Re-grout under inlet pipe. Provide ladder to access the structure(flat top with center hole?) CB 9 Re-grout the adjustment bricks and the frame. CB 3 Provide oil/water separator. Rotate top section to align with ladder. Provide hand hold step and hanging ladder. Could not inspect fully due to ladder. Re-grout under pipes. Provide round solid locking lid and raise to proper grade. Investigate water entering CB from the west(does not exit CB to the pond). This may require TV-ing the outlet pipe or check for lift holes not grouted below water level. CB 10 Access hole and flat top was enlarged. Contractor has supplied a letter approving the enlargement from the manufacturer. Provide a galvanized steel ladder to access. Remove unused steps. Re-grout the flat top to prevent weeping and re-grout under the curb. CB 11 Provide thru-curb frame. This may require some modification to the driveway section. Re-grout under the lot drain pipe. CB 12 At present there is a solid lid. Lid is not of the locking type. The City may require a locking vane grate,or round locking lid. Sound Engineering will need to run elevations on CB 12 and CB 11 and provide the City with the lid elevations on both CBs. CB 13 Re-grout the pin holes under the outlet pipe and lot drain. Clean the catch. There is standing water in the outlet pipe just outside the CB. CB 14 Approximately 2 inches of standing water in outlet pipe and Re: Permit#00-103141-000-00-EN; Tresden Place Page 5 lot drain. Grout is okay. CB 15 The invert to rim elevation is greater than five feet. Re- grout pin hole under the frame. CB 16 Okay CB 17 Re-grout several small pinholes under the frame. CB 18 Re-grout crack in grout under the pipe. Replace the curb poured without expansion joints the corner of this CB and CB 17. Lot Drains Provide white 2 X 4 stub locating the end of pipe at all lots. Between CB's 10 and 12,a T-connection was made from lot 35. TV the line between CB's 10 and 12 to verify the proper connection was made. Provide a catch basin in lot 35. Contact the City inspector for specific details. Provide flow tests as necessary to test all lot drains. SITEWORK Provide locking stainless steel bolts maximum length 1 1/2"after final acceptance. Complete all sidewalk and driveway work as shown on the approved plans and not required per the grading plan for lots 1 through 8. Complete grading of sight per the approved plans or as advised by the City of Federal Way. Fill stockpile and grading plans for lots 1 through 8. Complete grading per plan. Maintain positive drainage. Provide interceptor ditch to gravel co-riser. Provide fabric as necessary around the gravel cone stand pipe. Provide the rock check dams at 100' for intervals. Fill all erosion ruts. Provide silt fence as necessary and maintain silt fence until all ground cover is established. Hydro seed all areas disturbed by construction or stabilize by other means as approved by the City of Federal Way. Provide mailboxes per the detail on sheets C-6 of the approved plan. Complete asphalt pathway tract B. Replace all existing street signs present prior to construction of Tresden Place per the inventory provided by King County. STORM- New CB added at CB grate is approximately %" under curb,concrete sub was MILITARY ROAD intersection of S asked to adjust. Clean catch. Cut pipe to with 1"of wall. 298"'Street New CB added to CB lid was paved over at ends and cannot remove grate to existing storm pipe inspect. Raise grate to asphalt grade so not to collect debris on west side of Military Road Re: Permit#00-103/41-000-00-EN; Tresden Place ' Page 6 CB 20 Clean the catch. Provide ladder to within 2' of bottom. Secure ladder. Re-grout all pipes, CB wall at gasket and inlet pipe. Remove asphalt under frame and replace with concrete grout. Inlet pipe to east is not true line and grade Dress up all areas disturbed by construction and hydro seed. Contact City inspector for inspection before hydro seeding. Coalescing Plate- Re-grout the outlet pipe. Provide steps to access. Clean the Oil/Water plates and the catch of all silts. Clean off all gravel from Separater the lid and provide the five-sided locking bolts. Gate Valve Provide valve marker post indicating exact distance to valve. Open gate valve. Storm Outlets Provide rip-rap pads per the approved plans. Inspect and clean out all storm pipe and catch basins of silt and debris 300 feet downstream of existing inlet or as directed by the City inspector. Provide ditch section on Military Road as shown on detail 2 of sheet C-7. Provide culvert under last existing driveway on the west side of Military Road. Provide acceptable method for property owner north of site to obtain mail from mailbox on Military Road. Keystone Wall Complete all site distance mitigation as required by Kim Scattarella. Rockery Wall Complete all rockery walls per the approved plans. Chink all the voids. Provide positive drainage to the nearest catch basin or pond. Street Signs Provide street signs per City standards. Street Lights Complete all streetlights per City Standards. Complete Punch List to be provided by King County. Channelization Remove all temporary striping. Developer to provide agreement with City to re-clean storm tract after home construction is completed. Irrigation Demonstrate operation and perform system operation. I:AcsdcAdocsysave\I4551(1333087.doc • SOUND ENGINEERING, INC. • civil engineers•land planners RECEIVED Our File No.: 99213.10 MAY 0 5 2002 April 30, 2002 'Iv AY F--L JL r,,,, Ke . y of Federal Way 33530 1st Way South Federal Way, WA 98003-6221 Project: Hunter's Glen Plat Permit No.: 00-103141 Subject: Punch-list Issues Dear Ken: I am sending this letter as a result of a recent walk-thru involving Mr. Gary Jones with S&W Utility Contractors and Mr. Jim Pryal, field inspector with the City of Federal Way. Attached is a list of items that were discussed during the April 29, 2002 walk-thru and at this time are unresolved. To begin, as noted on the attachment, these issues have been addressed as "may be requested". As a result, we are respectfully requesting your review of these issues and provide us with a written response stating which issues must be addressed and why. Please note that we feel these issues are construction items that are outside the scope of the originally approved plans with the exception of item 7 which will be completed as part of the punch list. For example, items#2 & 8 are outside the scope of the approved plans while items#1, 3 & 6 are changes to the approved plans. Understandably our client, Paegeantry Communities, is requesting a clear explanation why these cost impactive items are being requested at this late date. As you may know, we have maintained a cooperative relationship with the city throughout the duration of the project. As an example, there have been past field related issues that have been resolved in a timely manner via joint cooperation involving our design and construction teams and city engineering staff. In fact, a storm drainage issue was resolved less than 5 weeks ago. At that time, after the resolution was agreed upon, we specifically asked Mr. Pryal and Mr. Jim Femling if there were anymore issues needing to be addressed, as we were quickly approaching the final plat phase of the development, we were told "no". I'm sure you can imagine our concern when these new issues were brought to our attention on Monday. ST1 1019 Pacific Avenue,Suite 906 Tacoma,WA 98402•(253)573-0040•FAX(253)573-0142 May 2,2002 Page 2 Again, I have to stress the need to resolve these issues quickly as possible, since Pageantry is trying to complete the final platting phase of the project. It is extremely important we receive written explanation if any of the attached (8) items will need to be completed for final plat approval. In addition, if any of the items are changes to the approved plans and/or outside the scope of the approved plans, please explain why the city is requiring the additional work? If possible please reference City of Federal Way code where appropriate. Your timely response is very much appreciated. Please call me at 253-573-0040 if you have any questions and wish to discuss the concerns further. Sincerely, Timothy D. Holderman, P.E. Principal cc: Bryan White, Pageantry Communities, 25400 74th Ave. S, Kent, WA 98032 Gary Jones, S&W Utility Contractors, 9416 Front Street South, Suite A, Lakewood, WA 98499 enclosure F:\letters\2002\99213.KenMiller.05.01.02.doc Sr ' 2 J' , we/30/2002 09:30 2538549710 PAGEANTRY CONNUNITIS E�41�812892 88:18 25358G0b PAGE 02/02 58d+1 UTILITY CCNT.At PAGE 01/01 Utility Contractors T000rrta- WA The following ate items of concern as expressed by Tim Pryal during a site walk through on April 29th,2002. We will require specific direction as to how this work is to be accomplished. I. The handicap ramps within the Military Road Right-Of Way are placed per the design on Page S of the plaits and specs. The City lily WW1 to revise that detail requiring the ramps to be removed and replaced. 2. The City may request that a culvert be constructed ar the Military Road at driveway on the west side cf approxims Sta. 100+00. No culvert existed at that location prior to beginning the project. 3. The City may require a driveway approach be constructed 4ttlte entrance to the detention pond and as a result relocate the handicap ramp at that location. No driveway is shown on the plants at this location. .. Drain,clean,and re-hydroseed pond after all grading is completed. 3ecause Lots were not cleared or graded prior to final pat,this necessitated the stockpiling of Material n other areas of the site for later use. 5. Stockpiles of material intended to fill Lots 1-S at a later date may be required to be removed from the site prior to final plat. 6- The onsite store drainage for Lots 33-35 are Tied into the system with tees as indicated on the plans. The City may require a Q3 to be placed at that location. •, The City may require ao additional drainage ditch along the east side of Military Road. 8. There may be s sight distance problem from 298th on the west side of:\rdirary lookingi :torh. rg.*21 l ? 11C1( FAX" i From: IcuwN. � pow F Irk 9416 South Front Street.Ste.4-i..eiteweed,WA 98499(253)584-0660 Office (253)t -0668 Pax Contractors theme SWUTIQOg5LJ r FAX Sound Engineering, Inc. 1019 Pacific Avenue,Suite 906 Tacoma, WA 98402 Date April 30, 2002 / �/�jl/� r Number of pages including cover sheet 2 To: Jim Feinting From: 'Leah Dunsdon City of Federal Way Project: Tresden Place Project#: 99213.10 Phone 253 661-4196 Phone 253-573-0040 Fax Phone 253-661-4129 Fax Phone 253-573-0142 CC: Bryan 253-854-9710 ❑ Urgent. 12 For your review ❑ Reply ASAP ❑ Please comment Jim: Al Larson at Centre Pointe Surveying has surveyed the majority of the stockpiles located on Tresden and has calculated approximate cubic yards in each stockpile. Per a conversation with Bryan White of Pageantry on April 30,2002, there is approximately 5000 cy of soil in the approved stockpile location and approximately 4000 cy of soil in other stockpiles around the site. Al Larson calculated that the depression on lots 1-8 will require approximately 9000-9500 cy of soil to fill. Therefore, the site does not have excess soil stockpiled on site since all the stockpiled soil will be required to fill lots 1-8. Bryan stated that they have `cleaned up' the stockpiles and that several of the smaller stockpiles have been wasted in place and that the larger piles have been regraded to be flat on top. Bryan also said that they plan on hydroseeding all of the stockpiles. If you have any questions, please feel free to call me. Thank you, Leah Dunsdon `J LL ' \ \-"vX\ Senior Design Engineer Td WUSl :TT z00Z 02 'adH EPTO 2LS 2SE T : '0N 2NOHd I 'ONI `ONIa33NION3 ONf10S : WOi'Id j i r. PAGEANTRY COMMU ; PAGE 02/02 April 29,2002 Tim Holderman, As per calculations done by Al Larson at Center Pointe Surveying ,we have 9000 cubi yards of soils stockpiled on site. This soil is the fill the depression created o lots 1 8 0 This depression will require 9000-9500 cubic yards of soil to fill. • Sincerely, Bryan White • Ed Wd9b:Z T ZOOZ 02 'add ZbTO £ZS 2SE i : '0N 3NOHd I '0N I `oN I eJ N I JNa QNfIOS W02i� w CITY OF = • _ _ \v CITY HALL 33530 1st Way South (253) 661-4000 PO Box 9718 Federal Way, WA 98063-9718 December 3, 2001 Mr. Torgeir Hougland 28847 37th Avenue S. Auburn, WA 98001 RE: TRESDEN PLACE- (00-103141-00-EN) 2920 S 298TH STREET Dear Mr. Hougland: I am responding to your letter addressed to Mayor Park in regard to the condition of Military Road between S 290th and S 304th, specifically in the area of S 298th. A new single family subdivision is under construction at the intersection of Military Road and S 298th. This subdivision will widen Military Road along their frontage,installing new curb,gutter,sidewalks and utilities. Additionally, the existing concrete street will be overlaid with asphalt to improve the uneven surface and tie the new improvements together with the existing road, making it one harmonious surface. These improvements should be completed by spring of 2002. The contractor must wait for favorable weather to finish the frontage improvements and the asphalt overlay of Military Road. We appreciate your patience while the improvements are installed. If you have any questions, please call me at (253) 661-4196. Sincere %\i„N aii; , Jim Femling Development Services Manager JF:tm cc: Michael Park,Mayor City Council(7) David Moseley,City Manager Cary Roe,P.E.,Public Works Director Marwan Salloum,P.E.,Streets Manager Jim Pryal,Ins ector I:\csdc\docs\save\32009087008.doc , • Hr. T'geir t'ictG(..p/ ,I 0 h ,1 + l_. a8a 7 37 Avc- 5 /' , � �' - +fi 11 v h v r r w� i_S Q v,.r "sty Nti}',�«' , *i+�M i,t i } ` , / 7G0/ -/1/53 vUl .fi � h4 • a A: l; (� n A_.:��.,.l C IJ rLr/E —, USAZU-: D—Th „r 2 FPder4 / L✓ay C, ., jig/1 . 33 3P Firs/ WQy Sn_'/A City Clerks Office /meta / wa )�/4 7g003 City of;ederal Way // a.;s, s-. .t ...ye�er� - .,4' .4 �rl. :+wd C•.�,:.,;'d`"t rw:�%tS'+MwtJ,-r^+r. E . _ :. - • • • • dllt y ` I=< ` +- `..� t ^. < I' ti`.�5 , � e it s,,?`. �tr t • t . t� t;2 �- iz fi .r, , l`t: • I{t 0 Q o ,, C A 0 ;`: c c t e Q c .I 4 Z p 3 • v - - -1 A Q ~' n '. \ ti J J `I 0- S v' k, Q �\ c - \ ,, , c? q 'A \ i...:. (_, i\ h 1 1 c/; \ \ 4 - n C n -0 \`-• \p \ - ` ' C `C 0 n Y \ti .� \J > CC A C n A p z L a \� Y ;11� 1 '1, 1,1:I:i y 4 t:: 4 • tiE;• . • FAX Sound Engineering, Inc. 1019 Pacific Avenue,Suite 906 Tacoma,WA 98402 Date November 27,200l Number of pages including cover sheet 4 To: Jim Femling From: Leah Dunsdon City of Federal Way Project: Tresden Place Project#: 99213.10 Phone 253 661.4196 Phone 253-573-0040 Fax Phone 253-661-4129 Fax Phone 253-573-0142 CC: fl Urgent n For your review El Reply ASAP in Please comment Jim: The attached drawings are of South 298th Street and the property south of the road. Per your conversation with Tim Holderman, please consider our request to move the sidewalk adjacent to the curb on the south side of 298th. If you have any questions, please feel free to call me. Thank you, Leah Dunsdon Senior Design Engineer Td WdS2:ET TOOE 22 'AoN EPTO 2LS 2SE I : 'ON 2NOHd I 'ONPONI632NION3 aNnos : woad _,- . � ' 'V / • °p •. . _ t cn ID. . 4 47.41 c, • O /� a 1 4 g- en 77 • , .; 1 -- M , I? y 1 I O y) , c, ,,, ci_ ii . itsli •1 aO vJ_jo �w I i. ..., • • ,,,,... . . ma . t `o, I o �_ 10 � � . a j� nrim4 a---];;;110111" ' .�smr ,� o -- . . �./.. :,:,:,:, . .:::::: ... %.„ , , , . ,A,,, . - V Q) • 11 +L0 ' • vl s � , I CU . 4:_ iiQ Sri, \ I I �. c: \ / ¼ /t • IN m 1 Al d cu J� 14J F0�d �a 3 ! ��9 � s9 co J I 'gob III,; CD -C a L li U�� s0s O • Sd o > s �, t o 9 0 I a � o r-I 4 4 al dA -I,_• !A i'.if r.1,. 1-1.4 4 Al �C t 3 41-4) / 7 A/ /: fp CO Ed Wd92:ZT MOE LE 'A°N ZPTO 2LS 2SE I : '0N 2NOHd I 'ON I '9N I a32N I ON2 QNnOS : WOefd ���s 0 . 'A'''' V 77.i:--1 . . . . , —_S- olo 0 . ..---- 'ay .........7 Pk .v, / 11111411( 0 o P. a ~7,s ONh �l c<-. - .., \ t < CII •� v ' i r� a • O d V y os Ogis I �o• _-7 • I ,....,,,i, till . ...• : a 6:Ir —. 72—1*I Q lit C II o el • m ,`!,'� 'Q' '� l m • ei (� ,:,71/ rN. 41011/ � sma! S, �ma m . ./' s . 1 ' g^ o _� ° 4 J , 11 +�0 m 1 l d` �p asap�` f I 1 OD b • 6Q- QI 4 a ` a� - 4 - � a I � a s_, a, co F. as . TA OO • spa' C-I Q CU . 66a ° '• F" o s,I It; ,.; > m c 5 ` 9;b ••I irr .1 O a no I�i. L teu.S of { o sXi :.;L V i,Ia � 1 "' 9 6B O % mli • CO Ica E �D O r �f •ell Q.).. 1 :.(5) CD. .._, C C •6-1 01 > (0 v . O / L 2d Wd92:ZT TOOE LE '^°N EVTO 2LS 2SE I : '0N 3NOHd I 'ONI `ONIeJ92NION2 QNfoS : WOdd • �� �. r �.- w • - •" • 'j a c Z 1 j lii, • <--.._,. 11 C I- 4 E►, acJ z. O ,, it �a ' • =N , ; I -.. ‘M 41 1....--.Q I u T? , a� •o. r ' _ o • `t, / s s. o � m Q.a O iI . ! a I:5 N d 400 E �..• y!o . a h I r'' 13 i ii,•'"'I ii i . • AN u 1� `e I'' • i i A 41 Za''' - -." W Er - io . t,• s v • , ,. 74410 t + °' ^ 4 aI tt k 1 i•: 1 � Is. i - I ! + c 1 ' , ;b CC" UPoo- L. _ •401 1 I" Q) C CO - m a iF L " oNF, 00 i :: 1 I an.1 , 4 - I B .':G.. a mQ Cu r_ • k C:, a- ibk .....„ .., ,.... ...• ,,, Fs\ 0 1— `F` `Oa - I li I� � > a O1 Ni •J i e 9:4 NL�Jy 6 d 100 L ma / t . sv > V •. SJM 4 CI' I ..--..]°°"7 C .I. (C) 4 c n .. O1 O ,0 Sa W C 4-4 I '\ 1---i O .0 C-) aD c / o ¢ ro ro o 0r, o f i-4- L bd WdL2:ZZ ZOOZ zZ 'AcIN ZPTO £LS 2SE T : '0N SNOHd I 'ONI `ONIZI9ONIONd QNIIOS : WOeld CITY OF CITY HALL 33530 1st Way South (253) 661-4000 PO Box 9718 Federal Way, WA 98063-9718 July 26,2001 John Jensen Lakehaven Utility District PO Box 4249 Federal Way,WA 98063 RE: Permit#01-100660-000-00-SR; TRESDEN PLACE SEWER Dear Mr. Jensen: Roger Nix of Pageantry Communities has requested approval to backfill the sewer trench within the paved area of Military Road S with native material rather than 100% CSTC as shown on the approved plan sheet 8, detail 6. The request is hereby approved with the following conditions: • Soils Engineer is to be on-site during all backfill and compaction operation of trench area • 95%Compaction required,provide results of compaction tests to City Inspector on a daily basis • Restore trench by placing minimum 6 Y2"Crushed Surfacing • Remove and replace entire concrete panel per approved plan • Full width asphalt overlay required on Military Road S per approved plan If you have any questions regarding restoration requirements, please contact me at (253)661-4127 or Marwan Salloum, Street System Manager at(253)661-4095. Sincerely, Kathleen Messinger Engineering Technician KM:sah cc: Marwan Salloum,Street System Manager Jim Femling,Development Services Manager Jim Pryal,Engineering Inspection Roger Nix,Pageantry Communities 25400 74th Ave S,Kent WA 98032 fax 253-854-9710 Gary W.Jones,S&W Utility Contractors 9416 Front Street S,Ste.A,Lakewood WA 98499 fax 253-584-0668 Permit file 01-100660 Day file L:\CSDC\docs\Save\09639057.DOC • SOUND ENGINEERING, INC. • civil engineers•land planners RESUBMITTED Letter of Transmittal JUN 2 5 2001 Project No. 99213.10 TO: Kt i' S .L-HXaC'L- Project Name: Tresden Place City of Federal Way Subdivision 33530 - 1st Way South Regarding: Storm plan & Calcs. Federal Way, WA 98003 Date: 6.22.01 N ikti * b() - Ln (4 WE ARE SENDING: NO. COPIES DATE NO. DESCRIPTION 2 06.22 Military Road Improvements Storm Plan 1 06.22 Calcs. THESE ARE TRANSMITTED: FOR REVIEW Kim- The enclosed items are sent for review and approval. Please call if you have any questions. Thank you, Timothy D. Holderman, P.E. Principal C: FILE 1019 Pacific Avenue,Suite 906•Tacoma,WA 98402•(253)573-0040•FAX(253)573-0142 L:\sound\FORMS\City of Federal Way\cityoffed.way.letterof doc 0 Tresden Place Conveyance Analysis Rating Table for Circular Channel RESUBMITTED v, c4.ont¢, ���e, (1 ITT ccwr- oy- s.%�'c 9 D- JUN 2 Project Description 2001 Project File m:\99213\drainage\conveyance\99213.fm2 Worksheet 100 Year Analysis Flow Element Circular Channel Method Manning's Formula Solve For Discharge Constant Data Mannings Coefficient 0.013 Channel Slope 0.006000 ft/ft Diameter 18.00 in Input Data Minimum Maximum Increment Depth 0.00 1.50 0.10 ft Rating Table Depth Discharge Velocity (ft) (cfs) (ft/s) 0.00 0.00 0.00 0.10 0.07 1.43 0.20 0.31 2.21 0.30 0.71 2.83 0.40 1.27 3.35 0.50 1.95 3.78 0.60 2.74 4.15 0.70 3.61 4.4r 0.80 4.53 4.73 0.90 5.47 4.94 1.00 6.38 5.10 1.10 7.22 5.20 1.20 7.95 5.25 1.30 8.50 5.22 1.40 ,8.75 5.10 1.50 8.14 4.60 06/19/01 FlowMaster v5.13 05:24:22 PM Haestad Methods, Inc. 37 Brookside Road Waterbury,CT 06708 (203) 755-1666 Page 1 of 1 Proposed Ditch Capacity Analysis Rating Table for Triangular Channel Project Description Project File m:\99213\drainage\conveyance\99213.fm2 Worksheet Military Road Ditch Flow Element Triangular Channel Method Manning's Formula Solve For Discharge Constant Data Mannings Coefficient 0.030 Channel Slope 0.076000 ft/ft Left Side Slope 2.000000 H : V Right Side Slope 2.000000 H : V Input Data Minimum Maximum Increment Depth 0.00 1.50 0.10 ft Rating Table Depth Discharge Velocity (ft) (cfs) (ft/s) 0.00 0.00 0.00 0.10 0.03 1.72 0.20 0.22 2.73 0.30 0.64 3.58 0.40 1.39 4.34 0.50 2.52 5.03 0.60 4.09 5.68 0.70 6.17 6.30 0.80 8.81 6.88 0.90 12.06 7.44 1.00 15.97 7.99 1.10 20.59 8.51 1.20 25.97 9.02 1.30 32.15 9.51 1.40 39.17 9.99 1.50 47.09 10.46 06/19/01 FlowMaster v5.13 05:24:59 PM Haestad Methods, Inc. 37 Brookside Road Waterbury,CT 06708 (203) 755-1666 Page 1 of 1 Table Rating Table for Circular Channel • CN L,ez,T UfEo,Cf ' GX1Sj rril� �'T• (a-S Project Description Project File m:\99213\drainage\conveyance\99213.fm2 Worksheet Proposed 12" culvert at stairs Flow Element Circular Channel Method Manning's Formula Solve For Discharge Constant Data Mannings Coefficient 0.013 Channel Slope 0.076000 ft/ft Diameter 12.00 in Input Data Minimum Maximum Increment Depth 0.00 1.00 0.10 ft Rating Table Depth Discharge Velocity (ft) (cfs) (ft/s) 0.00 0.00 0.00 0.10 0.21 5.02 0.20 0.86 7.69 0.30 1.92 9.71 0.40 3.31 11.28 0.50 4.91 12.51 0.60 6.60 13.41 0.70 8.22 14.00 0.80 9.60 14.25 0.90 10.47 14.06 1.00 9.82 12.51 06/19/01 FlowMaster v5.13 06:02:28 PM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 0 Table Rating Table for Circular Channel Project Description Project File m:\99213\drainage\conveyance\99213.fm2 Worksheet Existing 12" concrete (Military Road) AT' v (a t p -rarioV Flow Element Circular Channel 1 Method Manning's Formula Solve For Discharge Constant Data ?E iz S.4 rye„ , (see S -ui '7 . I) Mannings Coefficient 0.013 kec,•_ _,t 430 Channel Slope 0.051900 ft/ft �� Diameter 12.00 in ww''% -t•d • - 6125 , 3 • pica : 4.0 Input Data SWee_ c fa 00% u Minimum Maximum Increment Depth 0.00 1.00 0.10 ft Rating Table Depth Discharge Velocity (ft) (cfs) (ft/s) 0.00 0.00 0.00 0.10 0.17 4.15 0.20 0.71 6.36 0.30 1.59 8.02 0.40 2.74 9.32 0.50 4.06 10.33 0.60 5.45 11.08 0.70 6.80 11.57 0.80 7.93 11.78 0.90 8.65 11.62 1.00 8.12 10.33 06/19/01 FlowMaster v5.13 05:24:40 PM Haestad Methods, Inc. 37 Brookside Road Waterbury,CT 06708 (203) 755-1666 Page 1 of 1 Table Rating Table for Trapezoidal Channel Project Description Project File m:\99213\drainage\conveyance\99213.fm2 Worksheet Regraded ditch North of Driveway W r04.i D.i 444 tv orvill OF Flow Element Trapezoidal Channel e»J pa ,,j Method Manning's Formula Solve For Discharge Constant Data Mannings Coefficient 0.030 Channel Slope 0.038000 ft/ft Left Side Slope 2.000000 H : V Right Side Slope 3.000000 H : V Bottom Width 2.00 ft Input Data Minimum Maximum Increment Depth 0.00 1.50 0.10 ft Rating Table Depth Discharge Velocity (ft) (cfs) (ft/s) 0.00 0.00 0.00 0.10 0.43 1.92 0.20 1.44 2.87 0.30 2.97 3.60 0.40 5.06 4.22 0.50 7.73 4.76 0.60 11.02 5.25 0.70 14.98 5.71 0.80 19.63 6.13 0.90 25.02 6.54 1.00 31.19 6.93 1.10 38.17 7.31 1.20 46.01 7.67 1.30 54.73 8.02 1.40 64.37 8.36 1.50 74.97 8.69 06/19/01 FlowMaster v5.13 05:25:16 PM Haestad Methods, Inc. 37 Brookside Road Waterbury,CT 06708 (203) 755-1666 Page 1 of 1 0 Tresden Place Conveyance Analysis RESUBMITTED Rating Table for Circular Channel �t, oy. t,rc -�a.►� JUN 2 5 2001 Project Description Project File m:\99213\drainage\conveyance\99213.fm2 Worksheet 100 Year Analysis Flow Element Circular Channel Method Manning's Formula Solve For Discharge d) 2 81 CFs �r .pry on Constant Data Mannings Coefficient 0.013 Channel Slope 0.006000 ft/ft Diameter 18.00 in Input Data Minimum Maximum Increment Depth 0.00 1 .50 0.10 ft Rating Table Depth Discharge Velocity (ft) (cfs) (ft/s) 0.00 0.00 0.00 0.10 0.07 1.43 0.20 0.31 2.21 0.30 0.71 2.83 0.40 1.27 3.35 0.50 1.95 3.78 0.60 2.74 4.15.> 0.70 _ 3.61 4.47 0.80 4.53 4.73 0.90 5.47 4.94 1.00 6.38 5.10 1.10 7.22 5.20 1.20 7.95 5.25 1.30 8.50 5.22 1.40 -8.75 5.10 1.50 8.14 4.60 06/19/01 FlowMaster v5.13 05:24:22 PM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 Proposed Ditch Capacity Analysis Rating Table for Triangular Channel Project Description Project File m:\99213\drainage\conveyance\99213.fm2 Worksheet Military Road Ditch Flow Element Triangular Channel Method Manning's Formula Solve For Discharge Constant Data Mannings Coefficient 0.030 Channel Slope 0.076000 ft/ft Left Side Slope 2.000000 H : V Right Side Slope 2.000000 H : V Input Data Minimum Maximum Increment Depth 0.00 1.50 0.10 ft Rating Table Depth Discharge Velocity (ft) (cfs) (ft/s) 0.00 0.00 0.00 0.10 0.03 1.72 0.20 0.22 2.73 0.30 0.64 3.58 0.40 1.39 4.34 0.50 2.52 5.03 0.60 4.09 5.68 0.70 6.17 6.30 0.80 8.81 6.88 0.90 12.06 7.44 1.00 15.97 7.99 1.10 20.59 8.51 1.20 25.97 9.02 1.30 32.15 9.51 1.40 39.17 9.99 1.50 47.09 10.46 06/19/01 FlowMaster v5.13 05:24:59 PM Haestad Methods, Inc. 37 Brookside Road Waterbury,CT 06708 (203) 755-1666 Page 1 of 1 • Table Rating Table for Circular Channel • &A L.V6"z.T V ► 1L. ST* ►0-S Project Description Project File m:\99213\drainage\conveyance\99213.fm2 Worksheet Proposed 12" culvert at stairs Flow Element Circular Channel Method Manning's Formula Solve For Discharge Constant Data Mannings Coefficient 0.013 Channel Slope 0.076000 ft/ft Diameter 12.00 in Input Data Minimum Maximum Increment Depth 0.00 1.00 0.10 ft Rating Table Depth Discharge Velocity (ft) (cfs) (ft/s) 0.00 0.00 0.00 0.10 0.21 5.02 0.20 0.86 7.69 0.30 1.92 9.71 3.31 11.28 0.50 4.91 12.51 0.60 6.60 13.41 0.70 8.22 14.00 0.80 9.60 14.25 0.90 10.47 14.06 1.00 9.82 12.51 06/19/01 FlowMaster v5.13 06:02:28 PM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 0 Table Rating Table for Circular Channel Project Description Project File m:\99213\drainage\conveyance\99213.fm2 Worksheet Existing 12' concrete (Military Road) Ar V^v( 1 -vk T>X-1 Flow Element Circular Channel Method Manning's Formula Solve For Discharge Constant Data ? - S"rJer &See s - F' '7 1) Mannings Coefficient 0.013 Lte?•_ = P _ Liao , 012 Channel Slope 0.051900 ft/ft Diameter 12.00 in --'t,.+v G • - `��5 . 13 Input Data SWet. 4 C, lq 0� Minimum Maximum Increment Depth 0.00 1.00 0.10 ft Rating Table Depth Discharge Velocity (ft) (cfs) (ft/s) . 0.00 0.00 0.00 0.10 0.17 4.15 0.20 0.71 6.36 0.30 1.59 8.02 0.40 2.74 9.32 70..50 4.06 10.33 0.60 5.45 11.08 0.70 6.80 11.57 0.80 7.93 11.78 0.90 8.65 11.62 1.00 8.12 10.33 06/19/01 FlowMaster v5.13 05:24:40 PM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 Table Rating Table for Trapezoidal Channel Project Description Project File m:\99213\drainage\conveyance\99213.fm2 Worksheet Regraded ditch North of Driveway V,/i0.a.i t O�T�.�-F rr� TH OF Flow Element Trapezoidal Channel mJ(9 pds �/4J Method Manning's Formula Solve For Discharge Constant Data Mannings Coefficient 0.030 Channel Slope 0.038000 ft/ft Left Side Slope 2.000000 H : V Right Side Slope 3.000000 H : V Bottom Width 2.00 ft Input Data Minimum Maximum Increment Depth 0.00 1.50 0.10 ft Rating Table Depth Discharge Velocity (ft) (cfs) (ft/s) 0.00 0.00 0.00 0.10 0.43 1.92 0.20 1.44 2.87 0.30 2.97 3.60 0.40 5.06 4.22 0.50 7.73 4.76 0.60 11.02 5.25 0.70 14.98 5.71 0.80 19.63 6.13 0.90 25.02 6.54 1.00 31.19 6.93 1.10 38.17 7.31 1.20 46.01 7.67 1.30 54.73 8.02 1.40 64.37 8.36 1.50 74.97 8.69 06/19/01 FlowMaster v5.13 05:25:16 PM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 TRESDEN PLACE SUBDIVISION GRAPHIC SCALE A PORTION OF THE NE 1/4 OF SE 1/4 OF SEC. 4, TWP. 21N., RGE 4 E., W.M. KING COUNTY, WA (IN RR) b I boob m A. ` s. .'•::t•%, +- awn NAL w 1 1- 7IA�9.I9Ifi •J�iii.`✓\� moot 4L—`,, R Q aaot swat t."raI 5 q-•\ Qua.w 90Ii. 444444= E 9•rI Ptl 412'OR 4■OIA,NFNUiEVER 5 GREATER •�.� g[arNl.a 9QT Q \\\�r _ \`, .. i 2 NOTED ON PLANS •muss O1HERgSE \\ \ • �+ WELT MO sGN-aR NI SOLI PPS A x\ MO GRIMM 0'Rr MO CMS XII v°v°v°v°v )�, aa AFQAaD m01 '�� ��� IN.6...W Cr owlet NIT MOM As • - ._. ... -� ., O O O O O O°C i gall n.cmil ` ,� Z__ _aEMO n an MUM - - - _ -- '� _` ff � O O O O°O O O O ) O N THs 9ecr - _ `-1 �.� �116'y� ��4 • 1 �( O°O°O°O�0 OUTFALL PIPE ` ' id' /•��� �'� 0 I i PLAN e. .. A70IA9E owns nTa va • GVA$ .I' 4734 ' � r'`;li� �^�...�" CMS na Mt.&OW i rj/� 01 ' ., _J I` cO C` ,y•4 `31111.11%1, 1/44 9'ALL eorral K IC4AOO I pp--��� `SS oro1 AS COWED Ft • T) ♦ c p)if P O 0 ,( rovat ' `, _"iy 7(aOE1E OAgtr an MUM /� //� � ��,-44000 , � '��Sy0 (OMIf l0/?3/01 s....+e < 97.60S 1R LLS TO wW1 A,N'� t`�, �• ♦%� --�—I COSTING A14�� r� !g " � •'�: era Nam I�` /;, -�.- ,: PROPOSED GRQUNO� O $e& ♦ O O Er 41N.FACE QUARRY ROCK _ :`.� j':/ / �� JO00^ 12'MMN.A&DEPTH(T2'•PIPE) °$ �'z ��\ �o'a: o t� ��I 19'uIN.DEPTH ps'-Taro PIPE) r1 " I / w 1 ..a.-,e. ' " ..... ::Qyr :/4/�i�J ' SECTION 24 MIN.(24 J(Iro PIPE) • m a IOW \•`�\ , �`"'!� +� _ TYPICAL OUTFALL RIP-RAP DETAIL :� \:�� // /!� �i�•-\ - -=n O NOT TO SCALE j h:, \ I�, 1.2../C 4 ''',L\s`, •\\‘, -....*Vw e... •• • \ ir -\\\. . 4- .;(00-:, --- we..„_.-v ,-.. .e.i__, ............, . . v..,,r .49,41„ \ IiI 41,4 t 's'\• -\,&"•,,‘","1 jo,..„,,, ta1 if 7.;.(,..\ 44.11141 N.Ifte.#,Illifilli r_. II 71 11 yam 5 6 VARESI II O Jy c m I �"' VAIeEs COO I EASING came maw PAKD II.03 D95,•G CONCRETE I0.5'2 EASING Ca1NaEM RAM Ys—� I I �•. DC EOSING DITCH.BOTTOM al 910CLDER I � ...... II.O4 EASING CONCRETE 10.5'4 EASING CONCRETE TAMES EASIINO EDGE I STICULDER EASTN6 PTO( EDff OF NEW WOE TO YARN 7y Of Avflplr a EASING DITCH �OF PAWNOR CONTACT PROPOSED1 10 W 0.02 FT. 7.t _ '` OH'di I 0.02 FT. .t - Y 0.02 FT./FT.t 95;PROCTOR DENSITY V CC ! I .1y1MA* — Y cure CO dm r7:.t f I i OF PA1E9pIT ,II CLASS A 01E'I6AY R. -__ I J EIOSiNG CROLRp i na v 0' EDGE MOEX ROADWA %\�' \\" \� j I iC I OF PANJIOIi .tI CLASS A OLQRAT \ e\��\i/�lam BERM Y PANIC FABRIC I ?`� �i��i�%i %i\`Yi\`%\�%i��%i�bii z • PANTO FABRIC W F s 3 • r p NOTES NOTES ,N I.SIIICUT MOO FDCE 6 CONCRETE I MONIED BY OTT INSPECTOR. I.SANCUT EASTINO ECG(IX COCRETE IF RECLINED BY OTY INSPECTOR. CC i 2.PANG UNL BE PLACED ERNE PIAQDf111 CI ASPHALT CONCETE OWM AND AY OILY?K1ER THE 2.PANIC YABRK SHALL BE RACED UCTN BEFORE PUR ASPHALT CONCRETE MAYAlp d To DIE on ENTIRE AREA U SNHAS WE CRACK SEALED AMD PREMED. ENTIREENTIREAREA HAS BEE CRACK SEALED AND PRFMM:NI O' i MATEIALS ASPHALT CEMENT-AR-4OpI PER SECTO4 9-02 OMINOUSWIEMALS OF THE STANDARD SPEOFICATIONS MATERIALS, g FABIC-NONROYOI POTPROPYIpE MATERIALASPHALT 0307-AR-4000W PER SECTION 9-02 ORNIO7S MAMMALS OF TIE SWARD SPEOTCATKNS o vow-3 TO 5 025/SY FABK-N)1-3 T POLTPR/PILENE MAMMAL. rA TENSILE S ROGDL DTHER DRECIIGI-90L0S NNW ME 0 S 02S/5Y - ELOWiIOM-50%u••wIM T OSEL STRINGER OTHER°RECTIOL-9095.NNW - $ ASPHALT RETO190H -0.2 CAL/ST YN•RNI ELOGATION-502 l -0 � 'Paf-J00 ASPHALT REMRS( 2 GAL/SY WWII Ouelpned. KOl SURFACE MARE-HEAT-SET ON COW SERE WILING Pa1T-J00 SLAIACE IFA'RRR-IIAT-SET OI ONE 90E Ors-m KAIO PRINT pa 00.01 Clucked: TON Scale: CALL 48 HOURS MILITARY ROAD X-SECTION Date: 2/16/01 0MILITARY ROAD X-SECTION No.: 99213.10 BEFORE YOU DIG PRINCIPAL ARTERIAL NaTD sc.."' © Sheet No 1-800-424-5555 PRINCIPAL ARTERIAL "°"°SC" C7a1 7 c1 9 Sheets SS.nw w n'••n ID•M•aka-- nTt. AM II aml lieu rwru awl 1•as•. r ---(1 TRESDEN PLACE SUBDIVISION GRAPHIC SCALE A PORTION OF THE NE 1/4 OF SE 1/4 OF SEC. 4, TWP. 21N., RGE 4 E., W.M. KING COUNTY, WA - a„ �N, ,� _ 1 Inc!w 50 ft ...titiVy •• 01/A6 Feu PAD 1 /�` •- PILETS:3 �iLsoECroAs w �r RCQ4N 17111f0 pro POI t� 4:4,\ , �� DUAL 1169ay 0 / r W... 'i r r4a 421 ������� rgair ` awtYr svN!v/n //��11�� •12'OR 4>t qA.,WHICHEVER IS GREATER .��OIHERYASE �,� �� , , '*....-v `Y ,c�j ,NEPE 4 r .. ...�..... e 2 NOTED OR PLANS ,`\� • \ 0641-0.11 PAL MY PPE � ' MnuaeAaxDro ` ''��— OpOpOpOpO ,OpC ' .��' `` DD-saAM If I76111G rLr ANDAYI As w— �r- NEMroom0104 �•• '`G' DIECrmInanN91ECra .. e W OOOOOOOOO O C scn N maxi `an 4 —� _ _ < Ka xi , yV ��s , - - - ! ,� * O O O O O W 1FALL PIPE awm LSPNLTHIS MO A, -�:� — 1 O D.N0�0 `��, sE xrAt lHas 9m /- ���%/ 1,� -`w !>'�IIWW . a5 0-0-0-0-0 p p p 0_0 O C i?a f"B'"h'``� .. krw " iI/� —t •�•,�•. . ��� ., OHO Or O O O C �F�e� 'may rtitti'd .. f140.11 "::::19 \ 45 , : PLAN 1,1 ` \' NOGR COM OrtG 1FA i ► / ^A `'A ' ... CCM 116 sat away •rii lll,�/I' • _ J L Flo NLL 0 �,,fe„T -.,Y1 9MLL EDON Of KOKO ...... gl ,�I •CI � PP��y�i(( �, �� BY /IIIP4 OTT MDR }4 '" • `' ��, �¢O� _ Iowa m/73/mi ' • it COWEN CLOW ��`�� � EXISTING AND/OR O o o �••-.••• Q'� ` �,: 7.Ni w LEY ro wn1 M rriitfai'' • ./ — PROPOSEDCROUNO2U ` "' o"tga1C„at, ?' iy.,/4 ,�a a 00 9' B•MIN.FACE QUARRY ROCK '.\.., ♦�►� ..se .'.'..+% �!i/,�r_,��s "; O r T. 12•MIN.DEPTH(12•.PIPE) 4 3 ril _� `l: a •, �'�'3,.tV; �,'� .-��i���l� ^ le'MIN.DEPTH ps•-1a•i PwE) C� �`'! `✓,„5� ,`iLs; � � 0,�• 24•MIN.(24•-JO-i PIPE) �e A.• 'k. 11. ,-,„,l y L_ _ TYPICAL OUTFALL RIP-RAP DETAIL g a sl `5 � —+; 411:0 NOT TO SCALE E 0 7.4,0c..14 C27 , """'"2.;f:\\ . -"-N---t.''-'4'.',-"'d' ''',00'4Ple4r,:. > ...1-viit*;"*.11, idlvt- il .\,.\ ,:v8iN',1,,, /1:// AN '. fi 1 : rdt „ •-,••-cv4op,--,1,;,!,, I v/ I*4...-4440, .4/gf r-i .i ( Z rired siNks- -,...,\ ..z,'',1,47. -qu%\'1÷ ,g41,....'"*%, r .AM ChAi il & ik ik 1 o a IS CC O' VARIES I VARIES I y gi.gC! - VARIES—y — DOING 5 0H. MOT ( ( DOSING GROUND FIOSIi1G PAVED 11.03 ERSING CONCRETE 10.5Y E7051WD CONCRETE VARES `r,Y ' DOTING GROUND DOSING PAYED II.OL ENSING CONCRETE 10.5't EXISTING CONCRETE VARIES COSTING EDGE D NEW p170 TO TTOM W SHOULDER EOf.E e,. SHOULDER OF PAVEIENT MOW Oi EIOSIMG ma F705TNG OTCH OF AVEMgT COSTING 0101 COPAC7 PROPOSED BERM TO V Q _/ _ 0.02 FT. T.t It _./ 95t PROCTOR OFNSTY. �• a _ Q02 FT. T.t s t CUT OR ( Q02 FT. T.t GMT CR j 0.02 FT. .t \ Q sc i nu tY •S EXISTING .16 CLASS A oY�OArwAr _'Y' _____ (�COSTING GROUND Fu.tY Wy'.�i' i� ,y%i<%%���%,., AVG..a s,•16'GIASS•A VIE%AY r %`i,` ,•6',\ \ //\.\I B, Q�/c.`° G % % ','ice%i;.V,.7,7 7,\Y W S < - PAR K',FABRIC I PAVNG FA00C S. i 7 yI NOTES NOTES W e 1.SANWT EXISTING EDGE OF CONCRETE IF REOIRED BY CITY INSPECTOR 1.SAWpR DOSING EDGE OF CONCRETE IF REOJNfD BY Ott NSPECTOR CC ' m 2.POING FABRIC SHALL BE PLACED BEFORE PLACEMENT CF ASPHALT CONCRETE OVERLAY NO OILY AF1ER THE 2.PANNG FAODC SHALL BE PLACED BEFORE PLACEMENT CI ASPHALT CONCRETE OVER AY NO OXY AF1ER THE ENTRE AREA HAS BEE CRACK SEALED AND PRIMED. ENTRE AREA HAS BEE CRACK SEALED NO PRDFVFIFD. g MATERIALS RAIEOALS e ASPHALT CEMENT-AR-400041 PER SEVEN 9-02 01111I1IOS MATERIALS CI TIE STANDARD 9'ECBICAIKNS ASPHALT CEMENT-AR-4000N PER SECTDN 9-02 OIIAONOUS MATERIALS CI NNE STANDARD S€EOFIUTKK6 m FARO-NOIIKOVEN PO.YPREPYIFFIE RAMON- FOC-NONWOVEN PO.YPNOPWFNE MAIDDAL KW-5 i0 s 02S/SY TOOIr-5 TO H0OTHER ^ � � A��� U N TENSILE S1NfNClli D,IIFR DIRECTION-SOBS MINION IF1191E STRENGTH,OTHER MOM-9O8S MNIMI ERr_y$I '�B LLOGA110N-50%IRONY ELOGATKN-50S MNIMNI ASPHALT RE1ENSION -0.2 GAL./ST MUM ASPHALT REIE ISI@I -0.2 GAL./SY MINIM IELTNG PONT-LBO IELIRO PONT-]II0 Desi9nea. KOL SURFACE TEXTURE-HEAT-SET ON ONE SIDE SURFACE MOIRE-HEAT-SET 04 OE SKE D.fwn. KDH TAT Mo. J 2 2001 $�alekee.. r.o Dale: 2/15/01 JobCALL 48 HOURS0 MILITARY ROAD X-SECTION MILITARY ROAD X-SECTION sheet N 99210.10 Snee1 No.: BEFORE YOU DIG PRINCIPAL ARTERIAL NOT TO SCALE ©PRINCIPAL ARTERIAL N°T TO SDLE 1-800-424-5555 C7■1 k 7 of 9 Sheets 11IDW6 II,SIIIMITISSI.111.MIL Y6 WOOLS AN IS�1 1a 9 IN e1 SIGMA M.SS Leff ID K Si MATTES DAILY FIELD REPORT ADaPT Engineering, Inc. Project Name: ---r-agao,rki /tiicc- W.O.: Field Report#: 0 Location: 2 YJ' '- , //- Arrival Time: ir`,?o ri,� _ Job Number: Cl 5'- y "'1 rtztR4Z WAj'/ INf Page / of 2 Date: - j ( u S S M T W F ient/Owner: I G4Z .iil.J,C.t c Client/Owner Representative: 42.AO (3c i J-r,9 -. Contractor: Y--{ MI f�#11- C.vAr7 AC1t. Y Contractor's Representative ADaPT Filed Representative: MA./Qk /y,aA,ADaPT Office Contact: !`U R. Ga Q IC H 1 Type of Work:f t(. PC/t '1 ' it .. ity+4 A CjZ weather: JJ/VArM Equipment Used: \\Irs:(jf2 ..1 ( �(,( t ft.. Comments: c(!,VQ j e, f;+'P cv% hOi 4(f u-{ l .-k ( u tJ.i C —1. )fI J c J cki-t-"eir el Q.L , 'h c ) and c;,,„,yactefed .le-..,1-1(,_,-ci l 10. 11. f r/ ifia,v,-Itt..1- 4 . 4A ...1 `1--. P "cif (PEde J. tp Cu.rkeuc./ice t /7 de bP ,,m) .iQr^r%. irl ra f 4-te un G-1 -t‘;',N ffte.. 'e 0,1 pad i1c xi av , Field Density Tests Testa G f'NMA C.Location Approximate Approximate Soil Type Percent Remarks Test Elevation Fill Depth Compaction 32 Esc fNCL Vv f-, 4n r . H -1.o' _ fO` NA A_ q. %o 1 t.a• , o- ,, �-; Pq ii // _ '.v '0' q--T9,9 eg4j I have read and understand the con n of th' report. ,� ADaPT Field Representative: ,-/ itt" C/ ontractor's Representative: This report presents opinions formed as a result of our observations of the contractor's activities relating to geotechnical engineering. We rely on the contractor with the plans and specifications throughout the duration of the project irrespective of the presence of the ADaPT Engineering, Inc. representative. The presence of our field representative will be for the purpose of providing observation and field testing. Our work does not include supervision or direction of the actual work of the contractor, his employees,or agents. Neither the presence of our representative nor the observation and testing by our firm shall excuse the contractor in any way for defects discovered in his work. Our firm will not be responsible for job or site safety on this project. Reviewed by: r !Continued 10' d V9Z = ZO I0-170—unr .3 ' I I I / ii 1 I r I I /0. ot�� ' • j\ _ — — — • — l ._. ---- --- 1 \ / I / ......../ 4o l I I: g Jz i 7, ' 1 / l 128 a _ — — { (23 7 / 6 N, � 74, -\ 2i C �• - 31'8"- -- -, I , 7 / ` -'Si 1 \25 _ — f �o \ I / �' s I \ I 1 / 1 „_ — 1 _ _ _ _ Z _ I I _ -- 1---rgEs-ayv tot9cE Faa. fE tk er-r 1.0.._ ORrt 6-11-31 ZO' d V9Z = LO TO-17O-unf LSI ADAPT DRILY FIELD REPOF. t NO: t3 Project Name: T�IS Pr'Act. Permit No: Job No: CI -.ci Q, tzjk7 Time: I.v3P P.m Date: S Ut_ MTWT(BS5 Location: #\ 5 cea7't gANL W fly I WA Weather: ,ices -.rvAm rs? ?7ti r�Z>' Dient/Owner: htisp R t •-4(2C t\ Client/Owner Rep/Phone: (In�`0 a A�`� Contractor: It ;�CI L? C •)-3I2n�Mal Contractor Rep/Phone: I (").AAlk(W 2 S 3-51-4- Subcontractor: Subcontractor Rep/Phone: ADAPT Field Rep: MAr r 1,41.A 4N ADAPT Office Contact: k.M Z Ga�ESCt Type of Work: F'u. P(ACI iv)t4r C .1AApAC1 Equipment Used: 77.� .Ma)k Comments: Alt r ..eJ iln j, ke �2►'�t,.lc ( c C on 3Jck n .ke r c�Qi►1 {ti,1 -1 eS fiS +'/(>n Jr\ pia Le 3 .i C pu cfe f( . . 4 ..-,`1 i - .F} >�,�,ntS,ylt.y�y L '14 -F DIL r7w'2•.9 Qt� l' 4 > .p h''tr+ ' i ♦ 1 �� a yi •t,�r`: h 'W F a+ [] 1 y,S`-3rr. .'�`4vra.liiri`Wl►.:.W'.u:.3n� r..,,:.7C,+t..+ti �� ������F '!`-�'..... -:.�Deef<.11 ...��• ,� 1Na..:a�W�^+ ..x, 1. r' , x � : •,^�3�C •� .�: w TEST NO LOCATION TEST FILL DEPTH SOIL TYPE %MOIST. % COMP. PASS/ y DEPTH COMP. SPEC. FAIL CV 11 �OTIV.4011' + /V)t: JAI 1 Sp • :I- 9) f V)3, -11 ()Oki) 07 x,Arr tv Nist H S=az of gOLo /w�nlr�l: ,� ��. `' �%IU i ,t r4 1] L t. iF .t J -++' S Yy � +� c � � _'1`' - ..�- �l.�,,�,. 4 i-d'h +�„''4a.• SOIL MATERIAL DESCRIPTION %ROCK MAX. OPT. LAB. TYPE DENSITY(PCF) MOIST.% STD. S-Standard Proctor(ASTM D-698) M-Modified Proctor(ASTM D-1557) R-Rice Density(ASTM D-2041) This report presents opinions formed as a result of our observations of the Contractor's activities relating to geotechnical engineering. We rely on the Contractor to comply with the plans and specifications throughout the duration of the project,irrespective of the presence of the LSI ADAPT representative.The presence of our field representative is strictly for the purpose of providing observation and field testing. Our work does not include supervision or direction of the actual work performed by he Contractor's employees or agents. Neither the presence of our representative nor the observation and testing by our firm shall excuse the contractor in any way for Jefects discovered in the work performed by the Contractor. Our firm will not be responsible for job or site safety on this project. /kJ.1f rField Rep: Reviewed By: Page of Distribution:White-Owner/Client Yellow-Contractor Pink-Field File £0 d V9Z : ZO TO-17O-unr LSI ADAPT DAILY FIELD REPOR I` NO: /3- Project Name: 1i fOAIJ emu. Permit No: Job No: 9T-9O 7 Location: Z7Q+-6- Time: /1,15x,•41- Date: S'Z3'O/ M T Q T F S S /�Pto� ML IJA/V MA Ji'�Weather: c 1st"t Client/Owner: Gto arts- JiC't_ Client/Owner Rep/Phone: ea"t0 ar66(21-1-A-FF-- Contractor: Sew ch Dr`I eeotrr/ irro Contractor Rep/Phone: --Aim egewrow Subcontractor: " ,, Subcontractor Rep/Phone: ADAPT Field Rep: MA/lk 130 LJ41A-%1 ADAPT Office Contact: Iirrliei'r G'.otVcb( Type of Work: Jhnirk Si W(R Equipment Used: ti -Ms_ Co ments: Preg14 6n S'i4t 6j bek'7 of c + torl6QC - n �rr S tor corrtio^ aL bod Hkl dAti com t�.d c ov Tt1.1er- -l're scL, sc; s, o kx U% ro(eiT k place_ c - 'iti � t��d roc. ;1' 6e;� Cvnti-ruc &perry ., '� :, FI E19. vg Nov,]" ,STS "s..501L(ASTM D-2922/D-3017) TEST TEST NO Mee' LOCATION DEPTHFILL DEPTH SOIL TYPE %MOIST. % COMP. PASS/ COMP. SPEC. FAIL 0r-21 S-7 ' SP' 1 75 F'i AI 90 1 000 L _ Q.A _ Eri rt /� p�3l - LABORATORY TEST SUMMARY SOILMAX. TYPE MATERIAL DESCRIPTION %ROCK DENSITY(PCF) MOIST.% STD, A . �' y .J�dty�aV e w�f, -- VS- /35 1 �„� S-Standard Proctor(ASTM D-698) 12)Modified Proctor(ASTM D-1557) R-Rice Density(ASTM D-2041) This report presents opinions formed as a result of our observations of the Contractor's activities relating to geotechnical engineering. We rely on the Contractor to comply with the plans and specifications throughout the duration of the project,irrespective of the presence of the LSI ADAPT representative. The presence of our field representative Is strictly for the purpose of providing observation and field testing. Our work does not include supervision or direction of the actual work performed by the Contractor's employees or agents. Neither the presence of our representative nor the observation and testing by our firm shall excuse the contractor in any way for defects discovered n the work performed by the Contractor. Our firm will not be responsible for job or site safety on this project. 1.1 Field Rep: 1/ ""` /9' Reviewed By: Page 1 of I Distribution:White-Owner/Client Yellow-Contractor Pink-Field File VO 'd t>'LZ = LO tO—ti.O—unC LS1 ADA►.PT GAILY FIELD REPORT No: 6 Project Name: ;' n -q°1 ((�� �,1' PermitNo; _ Job No: ij Location: -=Ls �1 . 1 I Time:_.Z`jORi�- Date: -'c ( _ M TWO F S S W Weather. -04a11- Client/Owner: _ Yc Client/Owner Rep/Phone: P28O 2 Q.Pf wf contractor: :) C Q,ti V Contractor Rep/Phone: "rev% e1AIko p/ Subcontractor: Subcontractor Rep/Phone: — ADAPT Field F,e ; r /V1AAJ ADAPT Office Contact: 11 JQT 4YQO�f_(I • Type of Work: 1 LI- E uipment U ed: _ (J 1 2!Ij. &cur140L ti r0� Comments.: mid °, St4t a^ ( J 61 1" coeta /1`1 cot,- auf e. is Cv 6. A �c c ) led -- c ow)rckded cArm. QWV free .b a c I/1 r atai IWt. i+\ I t 1.Sf Qr.tv •1i1 /"O'd Acre el f i '1r C .,, % iTY TESTSr�•as TEST NO .'..Y. '� A PP•LOCATION TEST FILL DEPTH SOIL TYPE %MOIST. % COMP. PASS/ DEPTH COMP. SPEC. FAIL —G-8' 4 q 9(0 90 e 0 .... • PPP:10 a.,..- i.ratl .�.t . � ; c •fi • s :s , ; d � k 8lG� I Z t,(' r iah §:SOIL TYPE MATERIAL DESCRIPTION MAX. OPT. LAB. /� T %ROCK DENSITY(PCF) MOIST.% STD. ry Grk-Li t- jro 1 %Nirf e L� ?j� q5 S•Standard Proctor(gSTgq 0-698) 1 1 Modified Proctor(ASTM D-1557) R-Rice Density(ASTM D-2041) This report presents opinions formed as a result of our observations of the Contractor's activities relating to geotechnical engineering. We rely on the Contractor to comply with the plans and specifications throughout the duration of the project,irres ive of the presence of the LSIrepresentative is strictly for the purpose of providingobservation and field testing. our does not include supervision or direction of the acrepresentative. tual presence performed by the Contractor's employees or agents. Neither the presence of our representative nor the observation and testing by our firm shall excuse the contractor in any way for defects discovered in the work performed by the Contractor. Our firm will not be responsible for job or site safety on this project. Field Rep: (1VL Reviewed By: Page of / )istribution• White-Owner/Client Yellow-Contractor Pink-Field File 50 ' d VLZ : LO to-170—unr LSI ADAPT c�. DAILY FIELD REPORT NO: /-] Project Name: 1"(c�tTOON C _Pi ' Permit No: Job No: qQ-qo, JJ•Location: ZI6yS p Time: 9 =344 ABM • Date: S' S -e n MTWT�SS CiOca.AL �A�1�� Weather L4IM Q Client/Owner:((�� f� f O(ZL 4C i Client/Owner Rep/Phone: t .�, G aQSi Contractor: L4 U' C'1 C 12AC 1' Contractor Rep/Phone: ToM P4 i<O J Subcontractor: Subcontractor Rep/Phone: -"-- ADAPT Field Rep: /14,14k 301,44/)4/\/ ADAPT Office Contact: 1/4.11rt- aR) Type of Work:ShAh Si-wit'.- Q r- Equipment Used: R 271—±.2._t+QB'.A'C1" tjti 1� C7pL/� c Comments: Arr led CA Sf OA bic0 if 8f CIS- N C A- ✓10040 OV I- -IS !S 'r C‘Mt i0rk on, b l bL CSAAralc hd c r„�, S�Jk - �}'ie.�c . I1 So►(S. eor.k r�t�C� rtA 'is C%A{i A v`►'S 1ti bQ CQ*�Si"c* ) per- r ion , °4k.74ufiJ',1rrev,.: l1xTRnwe:+xK•rw+!n :rc,..n. ..,u.:.+.,cn..,.-.k...,., ,..,..,«_...�...........�,...4.,, ,a.. FIELD DEN$ITY'TESTS t1sTIL(ASTM D-2922/aso17) . . .,..... €'ram,, _ . , . .. ,,T __ .. . ... . TEST NO Gt"vrAp(. LOCATION TAT FILL.DEPTH SOIL TYPE %MOIST. % COMP. PASS/ DEPTHCOMP. SPEC. FAIL 00:3/ , s'ie lie/nW ,-7 0' S" A 9 q5 P 4c - ' S " _ A -> 9S P A-I -6. 101 A r30.55 90 P 4-2 -‘' co" A Y.q Cb 90 P 'f3 _-5~ 42' A 9/7 c coP r , , eLo 40e''..afkl :711r3:4 LABORATORY TEST SUMMARY SOIL MAX. OPT. LAB. TYPE MATERIAL DESCRIPTION %ROCK DENSITY(PCF) MOIST.% STD. A _ Gaul 3 A-3J-ue" ‘At/r;if- A- r35 S-Standard Proctor(ASTM D-698) f M olodifled Proctor(ASTM D-1557) R-Rice Density(ASTM D-2041) This report presents opinions formed as a result of our observations of the Contractor's activities relating to geotechnical engineering. We rely on the Contractor to comply with the plans and specifications throughout the duration of the project,irrespective of the presence of the LSI ADAPT representative. The presence of our field representative is strictly for the purpose of providing observation and field testing. Our work does not include supervision or direction of the actual work performed by the Contractor's employees or agents. Neither the presence of our representative nor the observation and testing by our firm shall excuse the contractor in any way for defects discovered In the work performed by the Contractor. Our firm will not be responsible for job or site safety on this project. 4 Field Rep: --gotemo-L-- Reviewed By: Page / of_ Distribution: White-Owner/Client Yellow-Contractor Pink-Field File 90' d 8Z = LO iO-t 'O-unC LSI ADAPT ��` DAILY FIELD REPOR I. f NO: 1 8 Project Name�R OV PL iC,L Permit No: Job No: qii-y dC1 Location: S. 2 W +h Time: I0:00,41-40.1 . Date: 5.-2-ci—Q t M T V1OF S S 1! kI I t1Jf et Weather: PAq'1 SWAM Client/Owner: t0REsi..'i2ct' Client/Owner Rep/Phone: 'II AO I o /tSri - Contractor: lfraM.XYLtCOArMACalaS Contractor Rep/Phone: 1OM PANkoi Subcontractor: —' Subcontractor Rep/Phone: — ADAPT Field Rep.p. MARK Qo�M� ADAPT Office Contact: Gu( ,4o 4- Type of Work: cR" Equipment Used: J v-i2lkAMlial R ou.t/2... Comments: Prr Nej o n S rk Oct 13 le-o f C l 'O Gando C.4— nljje Ar (I 434 tik.k `{6-ft -or (OrNeaCtigik in {146fr 110 of- rototed rtIcAv Wat_ --the._ confr,cikr- ceivwie..1 V J t1 anJ tjc ( rQIIS -fee:" p tok)' StC :0r. M FlE'.p DENSITY TESTS -e-sOIL(ASTM D-2922/D-5017) >St. 0 ASPHALT(A M D-2930) " TEST NO R°Cker'1 ,►ne, LOCATION W .._. ...v.. DTEST EPTH FILL DEPTH SOIL TYPE %MOIST. `� COMP. PASS/ (4e COMP. SPEC. FAIL °rept- N ..0 /_a ' A q ` 95 P 45 ProPcT� line. O I -O ' /�' 4 it P WI (o 'IL taT ck Mid f • 1 . ef eat - : • -45 1 A.V,T.#��R.a..•::r,r..c vsr....m=. .... .. .,. _...�__ -- , .. LABORATORY TEST SUMMARY SOIL . MAX. OPT. LAB. TYPE MATERIAL DESCRIPTION %ROCK DENSITY(PCF) MOI .% STD. i4 Gra.kitill s,H /044 -- 13z 6 til S-Standard Proctor(ASTM D-698) a Modified Proctor(ASTM D-1557) R-Rice Density(ASTM D-2041) This report presents opinions formed as a result of ourobservations of the Contractor's activities relating to geotechnical engineering. We rely on the Contractor to comply with the plans and specifications throughout the duration of the project,Irrespective of the presence of the LSI ADAPT representative. The presence of our field representative is strictly for the purpose of providing observation and field testing. Our work does not include supervision or direction of the actual work performed by the Contractor's employees or agents. Neither the presence of our representative nor the observation and testing by our firm shall excuse the contractor in any way for defects discovered' the work performed by the Contractor. Our firm will not be responsible for job or site safety on this project. Field Rep: /41.-Aueyv7o.ev-- Reviewed By: Page L of 42 Distribution: White-Owner/Client Yellow-Contractor Pink-Field File LO'd V6Z : LO I0-170-unr LSI ADAPT DAILY riELD REPORT (CC,r4T'D) NO: 1$ Project Name:lRl lOti\I Plrr7C►. Date: 10 -00 4M- Job No: 9Q -Co 1 Comments: Atiofs4 CI tine_ arelk .iur .VVl JW 1 Of- •Pro posed LJ��J . l • �i Wen_ /e�.v e 4h cor a (J a-J( 1, .( {'?rr1 infb verexcava 'e d ;r in g ��ll Q �*'�G► b1' y , er area +4 f +i rvi grale.. Q -t Is oer& cvlaocte d c),. 411i S Yew of- P laced -CitLif' f—ille 9na r3cKs.r co ,AU ACo elf trUttdd yy 1 twile‘ jilt tsf p f-lor n fl k$r ,A r i Ifathon r c IA Pro yA . Field Rep: ee) (init.) Reviewed By: (init.) Page 2 _Oa__ Distribution: White-Owner/Client Yellow-Contractor Pink-Field File 8O' d VOE : LO IO—t'O—unr LSI ADAPT L',- ILY FIELD REPOR I INO: tcr Project Name E.SPI PIACX_ Permit No: Job No: Q4?'q 61 Location: S j Time: r 4-#77. Date: :0 0 1 M T V�f F S S ,C$L p L L A l j VGA Weather: OV ' ?t-' Client/Owner: Pi-oi (z.d . t Client/Owner Rep/Phone: CS erfcvGw4J-i- { - Contractor: %r Contractor Rep/Phone: �TbM eMSACCO / Subcontractor: Subcontractor Rep/Phone: ADAPT Field Rep: M Aik i3 WV/✓ 1•/ ADAPT Office Contact: - j1 .Jftj" Ga0 .(-t Type of Work: RUCICtlin 1 Equipment Used: Comments: f rni�eJJ w' Sf'�C 4 b Q.L4'F Df e -ft obse vz C '1 kd^. of 4 on-Brit rockers III i'l /of areal' in M. Corner of 1'k• /Ic // Cons-'ructi cr haf no S -trili t ponJ -6 a co,utricte i Intl- P �16n it s de. eon . No ,s-f%thl Jewel- fr'Jt&1J4+Jo, llr t/1 liar. This report presents opinions formed as a result of our observations of the Contractor's activities relating to geotechnical engineering. We rely on the Contractor to comply with the plans and specifications throughout the duration of the project,irrespective of the presence of the LSI ADAPT representative. The presence of our field representative is strictly for the purpose of providing observation and field testing. Our work does not include supervision or direction of the actual work performed by the Contractor's employees or agents. Neither the presence of our representative nor the observation and testing by our firm shall excuse the contractor in any way for defects discovered in the work performed by the Contractor. Our firm will not be responsible for job or site safety on this project. Field Rep: Rd- P" Reviewed By: Page ` of_l__. Distribution:White-Owner/Client Yellow-Contractor Pink-G;.J,l Gila 6O 'd VO£ = LO TO—VO—unr Memorandum To: Tresden Place File ROM: Kim Scattarella/1 le�' CC: Jim Pryal Date: 05/22/2001 Re: Tresden Place Downstream drainage construction The offsite storm along Military Road S.,downstream from the detention pond will need to be redesigned to handle offsite flows from the proposed Detention pond. Field inspection indicated that the proposed outfall on the east side of Military Road S.will not have adequate conveyance for offsite flows. The contractor has been made aware of this problem. It appears that a closed system would be a viable alternative,as the proposed ditch does not address obstacles crossing the proposed ditch..`The nearest location for an outfall would the existing ditch along the north boundary of the acentTrailer Park,which is just over 300' northwest of the current location of the proposed adJ Semi-* outfall The';location of the Coalescing Plate oil-water separator on the west side of Military Road will treat `the st rmwater from the west portion of Military Road that will include sheet flow from the new y,. Holderman,P.E.,Sound engineer for this project is Tim Street. The design alongthe east side drainage system A redesigned downstream g • phone(253)573-0040. � g> needed to ensure that ::� of the capacity would be ��Mxl� y Road S. along with a hydraulic analysis Pa ty eam flooding from this proposed development will be created or aggravated. > < 1 . DAILY FIELD REPORT ADal . Engineering, Inc, Project Name717 E,O AJ f(„0CL W.O.; Field Report#: 6Location: S. z-1 d�'� ST: 9r-t o fit.!'i G i t Arrival Time: Job Number. 1-94 Fat zeNC W �/ wr'! Page i of Z Date: �'1-0 I S I tV T W T F Client/Owner: vt o (R43 Ove-tCct,S Client/Owner Representative: 42' /iz i ji- , _s__ Contractor: VTr(;LVTI OATK.A(11Z6144 Contractors Representative 1 E.11 PA,'4 t LJ ADaPT Filed Representative: MAZttc 846,1, ,►v\J ADaPT Office Contact: lc G2bjd f Type of Work: PL0C4.'trl Ptri- Weather: WI Ow-1..`1 fki^4^/s--t_ Equipment Used: ATi' i1 ROLLketi 1VJ,orNe 1114 J`,, y. Uov. cA. j j,( 9'J pTo r. Comments: AreNtA an s-k GPI 62. ,F o c. 1Qn'k- -6 co-6 * nuclear- densitti-1-eNt ccyr C)divi mr V Goole. -F.l l pkguiQnF Alktivat. 1 l'tt Cc''(?ozeor- i3 cwiiinLin -lizi wit fit_ root f It etatAlntAf v^ eO/Nyok ;v\ PAttilszch d acribe d toroli 0k Field Density Tests Test t 6 f/iA4. Location Approximate Approximate Sop Type percent Remarks Test Elevation Fill Depth Compaction \S SIE rlCLokto rt J crcf( • '�/ It164�,14 cis,- e4s1 IC t I' f 1441:rlh Cr)9- P.40 I have read and understand the co tents f this report. ADaPT Field Representative: � P, isk, Contractor's Representative:_ p e. This report presents opinions formed as a result of our observations of the contractors activities relating to geotechnical engineering. We rely on the contractor with the plans and specifications throughout the duration of the project irrespective of the presence of the ADaPT Engineering,Inc. representative. The presence of our field representative will be for the purpose of providing observation and field testing. Our work does not include supervision or direction of the actual work of the contractor, his employees,or agents. Neither the presence of our representative nor the observation and testing by our firm shall excuse the contractor in any way for defects discovered in his work. Our firm will not be responsible for job or site safety on this project. Reviewed by: ' 'Continued TO' d VSib= LO TO- TT-XEW I 1 I I S,�o \ /9 1 I I or,. / / le, I ,�� I I ! . . \� \ -- - - i r Z 1.3-i-- 133 r r5 / \\ / i I ‘ I f f I 1 / 4°_ _ I 1 ' / /' II__ rg I l \ _, J223- --` -- - I N - 137 (23 / / z$ -- — —I _ 6 \ / ./ 7z6 `\ 2-1" `` \ 138 — ^ \ �i _ _ \ \\ / l-I q S ._._1 I0 — — _ -- -- .3 o \ ` I. / \ \ I. I / I.71:1_ -- - - - � I I I t \ T ��5-(bN e4cE Lp Pao ,��,e;-,F Co. ont 5-1-01 ZO'd v9j7=LO TO-II-#EW , DAILY FIELD REPORT ADM- Engineering, Inc. Project Name: ' TQ cSaN PLI2KA. W.O.: Field Report#: 7 Location: S 2-1i S-r. Arrival Time: . �- �/O'1 ' ! � .�A' /�. Job Number. ftr L Wn'1 1 W A Page / of 2 Date: S`$-Ol S S WA W T F Client/Owner: C4 V l V W'' 45' Client/Owner Representative: g(e.cif e fl2f g- Contractor: S Lht 3'N'\ 0404T-ActtrOPS Contractor's Representative 1yk PA/sill-ow ADaPT Filed Representative: Muiif< 6'$Jft -A v ADaPT Office Contact: k:Ir'r CRACSC 4Type of Work: ' tZ(. ILAC.`c,Is^ t."-' eather. Oki or- Equipment Used: ( C..co2tias, f p -rA + \f 2 lQ Comments: At-i 011 OA S: e cam 69.1/A. G4- c ei - k Co d- rkidear ( I 4Q.Si for Cce c 'rtin EY1 p16..Ge a a„d ((t,v'p d f ch ' i bit. -1114, n o4). f Field Density Tests Test# Iocatbn GSC/�I4/��, Approximate Approximate Soll'Type Percent Remarks Test Elevation Fill Depth Compaction 19 scc fNancto svrt S /.2 i Noar /4% qi", Riff 20 II a "'7 ` i JAr ak 17,. &III Zt Ir ,i lo`-1 isttak, T7'Q Pivf f I have read and understand the co tents of this report. ADaPT Field Representative: " ( Contractors Representative: This report presents opinions formed as a result of our observations of the contractors activities relating to geotechnical engineering. We rely on the contractor with the plans and specifications throughout the duration of the project irrespective of the presence of the ADaPT Engineering, Inc. representative. The presence of our field representative will be for the purpose of providing observation and field testing. Our work does not include supervision or direction of the actual work of the contractor, his employees,or agents. Neither the presence of our representative nor the observation and testing by our firm shall excuse the contractor in any way for defects discovered in his work. Our firm will not be responsible for job or site safety on this project. Reviewed by: I Continued £O'd V9t': LO TO- TT -.EW V 1 1 I e-s ' �\ 1 1 r I i Z ' // / 4 � y , ' t ` /i I ol s z \ i ! ! I ! ' T' �' / \ 1 \ \ / l 1. •\ , 1 _ l f -- 1 I . I I _ _ § I / / \ �/ —-1 -- -- -- I I / ► — / / 1 -._[ I \ Z4 ." 7Zlo '.k 2; _ I / 1 1 -- - 5 1 \ \ i _1 —. 1 1 — — —4 o� ` I / _ ^i _ - 3 1 �` N. 1 I. i — -- - - _ P4cE lirrgEs:ayv ruAte#Rr s-b'-ol 170'd v917= LO TO- TT-XeW DAILY FIELD REPORT ADaP . Engineerin , Inc. Project Namf-44ark,1 Ae.0CCc W.O.: Field Report#: 5" Location: 2 'Iv � Arrival Time: 7 aaA..�.. Job Number: I/Y.---y4—/ ctRr+ A(. ' ) v`i Page / of S Date: 9—(1 I S S M TOT F Client/Owner: f cm.A.24 �'tS Client/Owner Representative: 8 /, Vt..3 n .,c 9Contractor: ciLl Lii t t it AINA CONT/21;MaSContractor's Representative �-ZYNN eA.Ni•kizziked ADaPT Filed Representative: MAO tR IJ OuJ/Yve./ ADaPT Office Contact: ru frr Gexo cj f Type of Work: ,L PEJ'7l.`IJ1fIcA 1 eather: Pc(r,4-1 C1 ,1i Equipment Used: s. Comments: Ptert4dad on 1- a,•, 6.12 ink IC 4f c A- fo c. ,4 -t- 4 wJec - Ae/ T,11 for co.,v,pc.d on, - P CCAt74(.6o - /qI eyofi- &ri-2 J ,21 acMc4 - // Y e- - ,c 4 +ikni e_ crF J,' , 4-- i!ocI e^ Con*: ri /4 a�,r ; .CEOc�r{eg ad:,- 40 /�'(►11 iO.r . -the_ +��- -!-ia o-F rack 1 :n 1'e Field-Density Tests P IQGer� bQ,h', ) -the c ,cfc b&c% 4-//ed ' vai ctil dam' , !e, ;.�5 s. Test# (►L•itflA(''Ogati011 Approximate Approximate Solt Type Percent Remarks Test Elevation Fib Depth Compaction ZZ PA crIctato ssrc ihrtk -so- J' ` n/grzet S‘5. R9/1 23 `t 'I -'", G ` << 90. /qv Z51 Gk 0 -41,V 4 1 ' 0 (K 70 19411 Z.f. k a moo' /-.21 tr 9 y..o J ;, k 1/ 4 cy .2-3' S'6 - AO • • I have read and understand the conte is of thi report. ADaPT Field Representative: fly- P. ontractor's Representative: This report presents opinions formed as a result of our observations of the contractors activities relating to geotechnical engineering. We rely on the contractor with the plans and specifications throughout the duration of the project irrespective of the presence of the ADaPT Engineering, Inc. representative. The presence of our field representative will be for the purpose of providing observation and field testing. Our work does not include supervision or direction of the actual work of the contractor,his employees, or agents. Neither the presence of our representative nor the observation and testing by our firm shall excuse the contractor in any way for defects discovered in his work. Our firm will not be responsible for job or site safety on this project. Reviewed by: [ Continued • 5O d H9j.= LO i0-II-SEW \' ‘ ' I " ' l'w l'' 7- r , /.... • er' \\ I I f I j 1 / orb � jI/ / ,/ \ I -- i is 7 �'t f35 -- / \ \ / ( I 1 l f / , °- _ ' f I `- -- - g / 7 ^ \ \_,/_ j2„ —i1 - - - / V l 3 __ .1/ V I zs — - _) \24 / / �, r, 1 — — --5 \ \ ‘ \'' / \ _I A- — — — 1 1 — — —4 �S \ 4b ,45 , /43 o 1 I / f — — 3 n \ l I I l \ , I I _ 1 1 rfi z _ _ I / I ( N re i N N. ,. I \ \ N ___ _ _ \ \ ..., — .T — _ �&ctry ei4c£ F. ioREpoRroF 7 0 5-9-ol 9O'd VLb : LO TO-TT -'vW DAILY —FIELD REPORT ADaI i Engineering, Inc. Project Name: ( R1do J3 k. W.O.: Field Report#: (A Location: J• 2 Id ' Arrival Time: , %3 # .Al , _ Job Number: cq"'ytil Ft..00AptL L.IA" I LIA Page t of Z Date: 51 t"'0 I S S M T W2F Client/Owner: �o 0, d.1.045 Client/Owner Representative: 1. (3IL,2 74c Contractor: PIJ 1 1 Q / t- ACtI 1 Contractor's Representative --ram f A4 pt j ADaPT Filed Representative: MA,** L'tik,JMAI•J ADaPT Office Contact: j4J4Z V G'4 ,c ui Type of Work:6- PL vr i,,tr-4-Ct"PAS Weather: IMO Ti \ .S`" Equipment Used: \1 (Zpertj Z t QeL.Lc/2 , O •P1?l`ik i a1/431-1-CtWt-40% Comments: (gray OA_ SITe. an 6‘tlec& of d $' -1.o . c. szk- tuck r- (A '). -fed-Is ' CoM fGCiidrl 0-k 3-fAl thatki ptieri Grd Cfev rc& So 1 k S. hp-i ConS'4r� ' ,,,, o 4 jgc�e,-rf- i in; ;tar.1 icu n tr{- ;" pr,,c reSi d uri n j v . Field Density Tests Teat I CeskrrutrAt. Location Approximate Appio dmate Soil Type Percent Remarks Test Elevation QFIN�Deepth Convection 0 2 St�C VI�OiO .l`L s'l� -2O' -(i` NP'#TxUFt Se,a P 2C1 u ti —24)E AfA 36 ti14 -2-o` 6 ' Aloirrik 9t .pta 31 !l ti -Z•o` 4 -$ Airok 9( ,e pc 1I have read and understand the tents of this report. ADaPT Field Representative: C1AV 1 - ()A. Contractor's Representative: This report presents opinions formed as a result of our observations of the contractor's activities relating to geotechnical engineering. We rely on the contractor with the plans and specifications throughout the duration of the project irrespective of the presence of the ADaPT Engineering, Inc. representative. The presence of our field representative will be for the purpose of providing observation and field testing. Our work does not include supervision or direction of the actual work of the contractor, his employees,or agents. Neither the presence of our representative nor the observation and testing by our firm shall excuse the contractor in any way for defects discovered in his work. Our firm will not be responsible for job or site safety on this project. Reviewed by: I (Continued LO'd VLt : LO tO-IT -A'eW 1 . V . 'r 113 r- �o \ I I ` ( I o ,` °�'29/ i j I I 1 TE \ _ _ _ \ Z t.'...‘ 02- 133 r r / \ \ / i -- l I 1 1 I— — —g / / \ / JA--. — -Air' .. -- — — ----I l -.z$ - .- _ _i i � l lI - -- -- \ .f — ) 5 I \ ‘ \Zs I _ --- I I _. -. L \ —. --- 9 I ► / r -- - -- _ - - 3 o \ l I I. / \ I I I / I` 'z ( N N. I I \ \ - T � \ \ ____ T _ LIgES AI PACE FLo AAoa;0 _.3_--- 0 S-IQ-ai 80-d VLL, : LO IO- it -SW t 0 Skbe 4 <61'4 VARIES, SEE PLAN VIEW 6'_yIEXISTING FENCE TO BE RELOCATED. I EXISTING z ; ` GRADE BIDDER DESIGNED 1.5 RETAINING WALL PROPOSED GRADE 1.5H:1V MAX., $FE NOTES ON PLANS REGARDING GRADE _ ELEVATIONS AT THE SIGHT DISTANCE LINE OF SIGHT. ALL EXPOSED SLOPES SHALL BE HYDROSEEDED, TYP. ADAPTER SKIRT TRESDEN PLACE SUBDIVISION A PORTION OF THE NE 1/4 OF SE 1/4 OF SEC. 4, TWP. 21N., RGE 4 E., W.M. KING COUNTY, WA �I cT51 MIN. DEPTH CRUSHED ROCK SURFACING z I I �R€MeVr EXISTING RETAINING WALL AND REGRADE SLOPE. /-2' MIN. DEPTH CRUSHED ROCK SURFACING r-EXISTING ROADWAY , SCEMATIC MILITARY SIGHT DISTANCE GEOTEXTILE FABRIC(MIRAFI 70OX V OR APPROVED EQUAL PROVIDE CB INSERT 'STREAMGUARD FOR MM V SEDIMENT' OR APPROVED EQUAL a MANUFACTURER'S NAME FOSS ENVIRONMENTAL ADDRESS: 200 SW MICHIGAN STREET SEATTLE, WA 98106 TELEPHONE: FOR INFORMATION: (800) 909-3677 ROAD SECTION NOT TO SCALE RETRIEVAL STRAP OVERFLOW (TO BYPASS PEAK FLOWS) SEDIMENT ACCUMULATOR SCHEMATIC DETAIL NOT TO SCALE 2' HIGH , RETAINING WAL 0. I CLINE OF SIGHT 46 45't YED Ej(! •� \ hE ILS�(1bT.�. ISTA 5+88f TO STA 6+33t REMOVE i BLOCK FROM EXISTING \ G WALL REGRADE SLOPE WITHIN (RIGHT OF WAY AT 1.5H:1V MAX, NOT TO EXCEED FINISHED GRADS A ELEVATION AT LINET. \ CONSTRUCT BI DE GNED RETAININ WALL 1' FROI PROPERTY TW 473.9 LINE AS REQUIRED BY RADES BW 471.9 (TYPICALLY BLOCKS I IGH). jI o !E 4 ISTA 6+33t TO STA 7+22t I REMOVE EXISTING RETAINING WALL'j IWITHIN RIGHT OF WAY, REGRADE SLOPE AT 1.5H:1V MAX., NOT EXCEED FINISHED GRADE ELEVATION AT LINE OF SIGHT. CONSTRUCT t ' BIDDER DESIGNED RETAINING WALL I I STA 6+33t TO STA 7+27t AS (REQUIRED BY GRADES (TYPICALLY 3 89, ITO 4 BLOCKS HIGH). STA 6+72t CONNECT TO EXISTING I FENCE. PRESERVE AND PROTECT EXISTING FENCE NORTH OF THIS POINT. (RELOCATE &/OR REPLACE 35t LF. OF i EXISTING WOOD FENCE TO 6' BEHIND IPROPOSED BIDDER DESIGNED RETAINING WALL STA 7+06t CONNECT TO EXISTING FENCE. PRESERVE AND PROTECT EXISTING FENCE WEST OF THIS POINT. IAPPROXIMATE TREE LOCATION. REMOVE EXISTING TREE IF THE TREE CONFUCTS WITH THE / PROPOSED IMPROVEMENTS OR OBSTRUCTS / THE SIGHT DISTANCE. / I / c>, f GRAPHIC SCALE ,n ae b ( IN FTET ) I inch — 20 ft. 1+00 ,er p0t' 1.7 lv T> yh fi' VICINITY MAP 1-=1/4 MILE 0 Z emu 10123 103 O N g O O tl f t ,tl Nhb fk: tl _ Z hb a � - N e In NOTES `" 1. THE SURVEYOR SHALL BE PRESENT AT TIME OF CONSTRUCTION g N TO VERIFY SIGHT DISTANCE MEETS ANSHTO REQUIREMENTS. rR z v am 2. THE CONTRACTOR SHALL MODIFY THE EXISTING RETAINING WALL AND REGRADE THE SLOPE TO THE LINE OF SIGHT, PRIOR TO THE CONSTKIC7M OF THE PROPOSED RETAINMG WAIL THE SURVEYOR \ o SHALL VERIFY THE SIGHT DISTANCE MEETS AASHTO REQUIREMENTS. O1 ox 3. HYDROSEED ALL EXPOSED SLOPES 4. PROVIDE AT LEAST 1' WIDTH OF CRUSHED SURFACING BACK •o Co FROM EDGE OF PAVEMENT (SEE DETAIL 1). W 5. INSTALL CATCH BASIN INLET PROTECTION ON ADJACENT CATCH M BASINS FOR THE DURATION OF CONSTRUCTION (SEE DETAIL 2). N 0 SURVEY BY W CENTER POINTE SURVEYING, 31101 18TH AVE. S. j.. FEDERAL WAY, WA 98003 W c (253) 661-1901 W SITE ADDRESSi d 29660 MILITARY ROAD �1 FEDERAL WAY, WA z Cap UTILITY NOTE W LOCATIONS OF SAID UTILITY AS SHOWN ON THESE PLANS ARE BASED ON UNVERIFIED S C§ PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. THE CONTRACTOR SHALL BE co RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF EXISTING W d.' z UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES Cd AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHAD. INCLUDE CALUNG 1-800-424-5555 AND THEN POT HOLING ALL OF THE ICIL EXISTING UTILITY LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. THE CONTRACTOR ACCEPTS FULL J RESPONSIBILITY FOR ANY AND ALL. DAMAGES THAT HAPPEN DUE TO THE CONTRACTORS FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL UTILITIES. o IF CONFLICT SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT SOUND ENGINEERING m TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION, SOUND ENGINEERING ASSUMES NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES. co x TOPOGRAPHIC NOTE D THE EXISTING CULTURAL AND TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS HAS BEEN 0 PREPARED, IN PART, BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, SO CANNOT ENSURE ITS ACCURACY AND THUS IS m c NOT RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR ANY ERRORS OR I ° N OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DRAWINGS AS A RESULT. 0. v Designed: LIVID PERW NO. 00.103141 Drawn: LMD Checked: TDH I� Date: 01/15/03 Job No.: 99213.10 48 HOURS Z`?A�c3 Sheet No.: E YOU DIG P�erbr� Oc.-rn,�r�°`� 1 .424-5555 �� . 1 Of 1 Sheets M:\99213\99213-SightDistance.dwg, 2/19/2003 2:57:57 PM, LDunsdon RE". JUN 2 9 2004 Eeaa or Edge of osDnait '\ Guy w TRESDEN PLACE SUBDIVISION GRAPHIC SCALE 50 D � � ,� 200 A PORTION OF THE NE 1/4 OF SE 1/4 OF SEC. 4, TWP. 21N., RGE 4 E., W.M. KING COUNTY, WA( IN FEET , 1 inch = 50 M a a° anlerline of ditch 2C awa"M 0 o IFN11.71f QUARRY SPALL PAD aP SEE DETAL THIS SHEET rro°sfonnnr pod PLACE SPANS PER INSPECTORS DIRECTION. v s' CDREGRADE DUSTING DITCH PER 42 w DETAL THIS SHEET. Power pole re anchor 2rwaallOa,a 'b . A a a a a a a a Elw4ll� CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 BEGIN REGRADED DITCH SECTION PER DETAL THIS SHEET 40' GROUND EXISTING PAVED SHOULDER EXISTING DITCH n m /FT. t Point on smowepa Pr pole Point on slope QUARRY SPALL PAD SEE DETAIL THIS SHEET Unknown looked v It VARIES 11.0t EXISTING CONCRETE OF PAVEMENT .16' CLASS A PAVING FABRIC b f< 11 p w � f� Cqa�be�/ s" 1Y � � �T• 10.5't EXISTING CONCREEXISTING EDGE VARIES —I TE OF PAVEMENT Nov � EXISTING GROUND ARMOR SIDE SLOPE OF REGRADED DITCH WITH 2"-6" QUARRY SPALLS. 8" MIN. THICKNESS AND/OR AS DIRECTED BY CITY INSPECTOR. NOTES: 1. SAWCUT EXISTING EDGE OF CONCRETE IF REQUIRED BY CITY INSPECTOR. 2. PAVING FABRIC SHALL BE PLACED BEFORE PLACEMENT OF ASPHALT CONCRETE OVERLAY AND ONLY AFTER THE ENTIRE AREA HAS BEE CRACK SEALED AND PRELEVELED. MATERIALS: ASPHALT CEMENT - AR-40DOW PER SECTION 9-02 BITUMINOUS MATERIALS OF THE STANDARD SPECIFICATIONS. FABIC - NONWOVEN POLYPROPYLENE MATERIAL WEIGHT - 3 TO 5 OZS./SY TENSILE STRENGTH, EITHER DIRECTION - 9OLBS. MINIMUM ELOGAIION - 50% MINIMUM ASPHALT RETENSION - 0.2 GAL/SY MINIMUM MELTING POINT - 300 SURFACE TEXTURE - HEAT -SET ON ONE SIDE .1 - - --.0 OF PAVEMENT 16' CLASS A ( PAVING FABRIC *12' OR 4 x DIA., WHICHEVER IS GREATER * UNLESS OTHERWISE NOTED ON PLANS O O O 0 ) 0 0��� 0 o min 0000)0� + N 000000000 OUTFALL PIPE wjCDQ pN dr1 O0O0O0O0O0O0 PLAN 0 0�r 0. �1v Nl1 PIPE O EXISTING AND/OR O PROPOSED GROUND O O O �'�� 8" MIN. FACE QUARRY ROCK r ID O C` O O C`�12" MIN. DEPTH (12"0 PIPE) 18" MIN. DEPTH (15"-18"0 PIPE) SECTION 24" MIN. ( 24"-30"0 PIPE) TYPICAL OUTFALL RIP -RAP DETAIL NOT TO SCALE NOTES: 1. SAWCUT EXISTING EDGE OF CONCRETE IF REQUIRED BY CITY INSPECTOR. 2. PAVING FABRIC SHALL BE PLACED BEFORE PLACEMENT OF ASPHALT CONCRETE OVERLAY AND ONLY AFTER THE ENTIRE AREA HAS BEE CRACK SEALED AND PRELE:VELED. MATERIALS: ASPHALT CEMENT - AR-40DOW PER SECTION 9-02 BITUMINOUS MATERIALS OF THE STANDARD SPECIFICATIONS. FABIC - NONWOVEN POLYPROPYLENE MATERIAL WEIGHT - 3 TO 5 OZS./SY TENSILE STRENGTH, EITHER DIRECTION - 90LBS. MINIMUM ELOGATION - 50% MINIMUM ASPHALT RETENSION - 0.2 GAL/SY MINIMUM MELTING POINT - 300 SURFACE TEXTURE - HEAT -SET ON ONE SIDE MW NO. MILITARY ROAD X-SECTION 3 MILITARY ROAD X=SECTION PRINCIPAL ARTERIAL NOT TO SCALE PRINCIPAL ARTERIAL NOT TO SCALE I Iowls 10/23/01 11 N *10 o D_' O " u W O O o ZZ a II V nlr-® op.e (L b TZ ko y w Jcq �C'z � m m e Er oa w Z z W Z W m � N z o U 7 Q �j O CA 3 �1 N • U 0-o 5 O/ U \4 U O tg Designed: KDL Drawn: KMB Checked: TDH 00-103141 Scale: Date: 2/16/01 Job No.: 99213.10 R MWRAITTIm JuNc7ol;i1 7 of 9 Sheets UPDATED JIIN 21 2001 13f 47, 50 PLOTTED AIN 21 2001 13, 47, 52 FILENAME- M \99213\99213—DS.DYG DWG CREATED MAY 25 1999 12f0N 56 CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 GRAPHIC SCALE (INFZEi') 1 inch = 50 & WET SEASON REQUIREMENTS (OCTOBER 1 TO MARCH 31) 1. THE STOCKPILE SHALL BE STABILIZED/COVERED IF IT IS TO REMAIN UNWORKED FOR MORE THAN 12 HOURS. 2. ALL MATERIAL NECESSARY TO STABILIZE/COVER THE SOIL STOCKPILE MUST BE ONSITE. 3. THE STOCKPILED MATERIAL SHOULD BE PROTECTED FROM WET WEATHER CONDITIONS AND POTENTIAL EROSION. THIS MAY CONSIST OF THE PLACEMENT OF STRAW, BURLAP MATTING OR VISQUEEN/TARPS. ALL OF THESE MATERIALS WILL REQUIRE MAINTENANCE THROUGHOUT THE WINTER. IF VISQUEEN OR A TARP IS UTILIZED, THEN IT SHALL BE TIED DOWN WITH WEIGHTED ROPES FOR WIND PROTECTION. SOIL STOCKPILE NOTES 1.IN ANY SEASON, SEDIMENT LEACHING FROM STOCKPILES MUST BE PREVENTED. 2. TOPSOIL SHALL NOT BE PLACED WHILE IN A FROZEN OR MUDDY CONDITION, WHEN THE SUBGRADE IS EXCESSIVELY WET, OR WHEN CONDITIONS EXIST THAT MAY OTHERWISE BE DETRIMENTAL TO PROPER GRADING OR PROPOSED SODDING OR SEEDING. 3. PREVIOUSLY ESTABLISHED GRADES ON THE AREAS TO BE TOPSOILED SHALL BE MAINTAINED ACCORDING TO THE APPROVED PLAN. m W 0 lq a E N omvo a' O " U W 00 p C S Mr- m (- U nib a o con NvN y v e w Ir z 0 m W Y ^t O N 0 U iN Q �j O D (n G3 (n • u c J o 5 C3 � U O F OD OD O 00 h ZQD fD O N O r y — ao ■ Dy W zOC O y UJ ..J Wa-U.0 V uz OD 0- c� Z Wy d> 0 W coJ W O W ` m m C 0 0 0 m 0 � N a U Designed: Drawn: Checked: KWL KMB TDH PEllff NO. 00-103141 E t,� a 9 S ag 8 � S�I - Date: 2/30/00 oyalo � y 9og Job No.: 99213.10 Sheet,'No.d C2ml 2 of 9 Sheets FILENAME, IY \99el3\99213-C, DUG, DYG UPDATED OCT 11 2001 14 53- 38 CREATED MAY 25 19" 12. 0& 56 PLOTTED OCT I1 2001 14, 57- 33