20-102710-Permit FinalCity or Federal way
Community Development Dept.
33325 8th Ave S
Federal Way, WA 98003
Ph: (253) 835-2607 Fax: (253) 835-2609
Project Name: TSVOR
Project Address: 2509 S 304TH ST
Building - Single Family
Permit #:20-102710-00-SF
Inspection Request Line: (253) 835-3050
Parcel Number: 092104 9300
Project Description: BLUEBEAM - Construction of a 3355 square foot 2-story single family residence with a 710
square foot basement, 195 square foot covered entry and a 560 square foot attached garage.
Includes plumbing and mechanical. ***4 Bedrooms; $600000 Estimated Selling Price***
Owner
Applicant
Contractor
Lender
ZHANNA TSVORCORE
ZHANNA TSVOR
NO LIMIT TILE LLC
OWNER 1S LENDER
CONSULTING LLC
11436 SE 301ST PL
10917 SE 304TH ST
11436 SE 301 ST PL
AUBURN WA 98092
AUBURN WA 98092
AUBURN WA 98092
Census Category: 101 - New Single Family House
Includes:
# 1
'#2
#3
#4
Occupancy Class;
R-3
Construction T e:
Tye V - B
Occupancy Load:
Floor Area (sq. ft.)
3,355.00
Additional Permit Information
New / Additional Sq. Feet - lst Floor .....................
1195
New / Additional Sq. Feet - 3rd Floor .....................
0
New / Additional Sq. Feet - Basement ....................
710
Occupancy #1 - Construction Type.... .....................
Type V - B
New / Additional Sq. Feet - Garage ........................
560
Plumbing Work Valuation? ...................... I..............
10000
Number of Stories ...................................................
2
Plumbing to be Included? ........................................
Yes
Will Certificate of Occupancy be Issued? ...............
Yes
New / Additional Sq. Feet - 2nd Floor ....................
1450
Occupancy # 1 - Area (Sq. Feet) ..............................
3355
BasicPlan? ........................ .............................. I....
No
New / Additional Sq. Feet - Deck ...........................
0
Mechanical to be Included? .....................................
Yes
Mechanical Work Valuation? ..................................
10000
New / Additional Sq. Feet - Other ...........................
195
New / Additional Sq. Feet - Total ........................... 4110
Occupancy #1 - Use .............. Residence (1 or 2
.................................. family)
Comprehensive Plan Designation ................ , SF - High -Density Zoning Designation............,.................................... RS 7.2
Residential
Total Valuation: 437,600.95
Mechanical Fixtures
Air Handling Units
Furnaces
Bathtubs
Lavatories
Water Closets
1 Fans
1 Hot Water Tanks
Plumbing Fixtures
2 Dishwashers
6 Showers
4 Hose Bibbs
CONDITIONS:
6 Fireplace Inserts
1
1 Laundry Washer Outlets 2
2 Sinks 3
2
PUBLIC WORKS CONDITIONS -
Applicant is required to extend the existing 4' walking path in S 304th St to a length of 8' (frontage
improvements)
This body of work will require a right-of-way permit along with a traffic control plan and a performance
& maintenance bond
t
CITY OF
Federal Way
THIS CARD IS TO REMAIN ON -SITE
Construction Inspection Record
INSPECTION REQUESTS: (253) 835-3050
PERMIT #: 20 102710 00 Address: 2509 S 304TH ST
Project: ZHANNA TSVOR FEDERAL WAY WA 98003
Scheduled inspections maybe failed if this card is not on -site. DO NOT LOSE -1111S (:A[W. Inspections are listed as close to sequential order as pe ssiblc
(read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card.
❑ SWM Precon Site Mtg (4400) ❑ Initial Erosion Control (4365) ❑ Footings/Setback (4110)
Approved To be done PRIOR to breaking ground Approved to place concrete
By Date By Date By Date
❑
Foundation Wall (4115)
❑
Drainage/Downspout (4040)
❑
Plumbing Groundwork (4190)
Approved to place concrete
Approved to backfill
Approved to cover
By
Date
By
Date
By
Date
❑
Slab/Concrete Floor (4255)
❑
Underfloor Framing (4285)
❑
Floor Sheathing (4105)
Approved to place concrete
Approved to sheath floor
Approved to install Flooring
By
Date
By
Date
By
Date
❑
Shear Walls (4245)
❑ Roof Sheathing (4220)
❑
Rough Plumbing (4230)
Approved to install siding
Approved to install roofins
Approved
By
Date
By
Date
By
Date
Mechanical Rough -in (4165)
❑ Gas Piping (4125)
Cl Fire/Draft Stops (4095)
Approved
Approved to release test
Approved
By
Date
By
Date
By
Date
❑ Interim Erosion Control (4370) Prior to scheduling a Framing inspection; ❑ Framing (4120)
Approved Electrical, Plumbing & Mechanical Rough -in Approved to insulate
and Fire/Draft Stop inspections must be signed -
By Date offand approved. IBC 109.3.4 BY Date
lx, Insulation (4150) Gypsum Wallboard Nailing (4130) ❑ Final Erosion Control (4375)
Approved to install wallboard Approved to install mud & tape Approved
By Date By Date By Date
Ell Final - Mechanical (4065) ❑ Final - Plumbing (4075) ❑ Final - Building (4050) '
Approved Approved Approved ,J
By Date 31311 v ✓ By � � Date 31�/ / a By Date
n Rough Electrical ❑ Final Electrical ❑ Right of Way
Approved Approved Approved
By Date By Date By Date