Loading...
22-100028-Permit FinalCity of Federal Way Community Development Dept 33325 8th Ave S Federal Way; WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name: MY HEAVEN 8t EARTH FOOT MASSAGE Project Address: 31835 PACIFIC HWY S Building - Commercial Permit #:22-100028-00-CO Inspection Request Line: (253) 835-3050 Parcel Number: 082104 9126 Project Description: BLUEBEAM - Tenant improvements to include creating new massage rooms. No plumbing or mechanical included. Owner Applicant Contractor Lender HARSCH INVESTMENT PROP LLC JAMES SMITH JAMES SMITHSMITH LLC TENANT IS LENDER PO BOX 2708 448 QUINAULT AVE SE 448 QUINAULT AVE SE PORTLAND OR 97208 OCEAN SHORES WA 98569 OCEAN SHORES WA 98569 Census Category: 437 - Commercial alt / add / conversion Includes: #1 #2 #3 #4 Occupancy Class: B Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) 1,200.00 Additional Permit Information Occupancy #1 - Area (Sq. Feet) ..................... .... 1200 Mechanical to be Included? ..................................... No Mechanical Work Valuation? .................................. 0 Is this an Online or O.T.C. application? .................. No Plumbing to be Included? ................ No Occupancy # 1 - Use ................................................ Professional .................... Services/Offices Zoning Designation ................................................. CC-F Occupancy #1 - Construction Type ......................... Type V - B Plumbing Work Valuation? ..................................... 0 Number of Stories .................................................. I Permit for Building Shell Only? .............................. No Will Certificate of Occupancy be Issued? ............... Yes Comprehensive Plan Designation ............................ City Center Frame No Fixtures Associated With This Permit 11 CONDITIONS: Fire conditions: A separate permit is required for the modification of the sprinkler and fire alarm system. Sprinkler coverage was noted as a problem during a special inspection. Verify all sprinkler coverage is correct. A minimum of one 2A 1OBC rated fire extineuisher is re.ciuired. PERMIT EXPIRES Sunday, 24 July, 2022 Permit Issued on Tuesday, January 25, 2022 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of WashinIQtan anj the City of Federal Way. Owner or agent: 1 Date: City of Federal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed bV City staff. Tenant Name: MY HEAVEN & EARTH FOOT MASSAGE Address: 31835 PACIFIC HWY S Suite F Includes: # 1 #2 Occupancy Class: B Construction Type: Type V - B Occupancy Load: 0.00 Floor Area (sq. ft.) 1,200.00 Owner Name: HARSCH INVESTMENT PROP LLC Owner Address: PO BOX 2708 PORTLAND OR 97208 Permit # 22-100028-00-CO #3 #4 'I' Z'14k-z4%, Building Official bate The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of tk., City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises. -1:k CITY OF Federal Way THIS CARD IS TO REMAIN ON -SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 22 100028 00 Address: 31835 PACIFIC HWY S Suite F Project: HARSCH INVESTMENT PROP LLC FEDERAL WAY WA 98003 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. a Footings/Setback (4110) Re -steel (4215) Slab/Concrete Floor (4255) Approved to place concrete Approved to place concrete or grout Approved to place concrete By Date By Date By Date ® Underfloor Framing (4285) Q Floor Sheathing (4105) Q Fire/Draft Stops (4095) Approved to sheath floor Approved to install flooring Approved By Date By Date By Date Prior to scheduling a Framing inspection; �7 Framing (4120) ® Insulation (4150) Electrical, Plumbing & Mechanical Rough -in Approved to insulate Approved to install wallboard and Fire/Draft Stop inspections must be signed - off and approved. IBC 109.3.4 By Date By Date 9❑ Gypsum Wallboard Nailing (4130) Suspended Ceiling Grid (4265) Final - S K F & R (4060) Approved to install mud & tape Approved to drop tile Approved By Date By Date By Date t2 Final - Planning 73 Final - Building (4050) Approved Approved By Date By /M'J Date Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date ..'U sprinkler and fire alarm alteration require a separate permit. No Building Department inspection unit Fire Department permits are applied for or SUR emails CFW Building Department no permit required for sprinkler system or fire alarm system. Doors shall be readily operable from the egress side without the use of a key or special knowledge or G3. I rt Doors shall comply with the following diagram. Several doors do not comply with the provided accessible approach and will need to be changed. 1 � SRmn I t�15 111) OfOO d APPMAO, Put >llde r--"— --- I I 1 1 6 I I 1 418 II le} Hingr Appmm*, Pull Sift ' Ilhrlhtluser ord W& rr xw;dod 46 me JUM Phdh dow WA WLh WM*d 5. 'IfIDd�closo• w4 IsM.n R-a PldfdM • —A I I I (Dj FrxR Approrch, Push Slds r�--------� I I I I (0 H6,0 ApprodO. PuA 910 6. ICC/ANSI A-117.1-2003 Table 404.2.3.1: ManeuveringClearances at Manual Swinging Doors Type of use Minimum Clearances Approach Direction Door Side Perpendicular to Doorway Parallel to Doorway (beyond latch unless noted) From front Pull 60 inches 18 inches From front Push 48 inches 0 inches' From hinge side Pull 60 inches 36 inches From hinge side Pull 54 inches 42 inches From hinge side Push 42 inches' 22 inches' 8,4 From latch side Pull 48 inchesz 24 inches From latch side Push 42 inchesz 24 inches 'Add 6 inches if closer and latch provided zAdd 6 inches if closer provided. 'Add I2 inches beyond latch if closer and latch provided 4Beyond hinge side Sire of doors: The minimum width of each door opening shall be sufficient for the occupant load thereof and shall provide a clear width of not less than 32 inches. Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees. ICC/ANSI Al 17.1-2003 Section 404.2.6: Door hardware configuration: Handles, pulls, C)Iatches, locks, and other operable parts on accessible doors shall have a shape that is easy to grasp with one hand and does not require tight grasping, pinching, or twisting of the wrist to operate. J. In a group A occupancy having an occupant load of 300 or less, Groups B, F, M and S, and in churches, only one, main, exterior door (or one, main, exterior pair -of -doors) may utilize 2006 IBC Section 1008.1.8.3 item 2. Clearly identify on the drawings the door or pair -of -doors to be considered the main exterior door. Show on the drawings how all requirements of IBC 1008.1.8.3 item 2 are satisfied. Item 2.1 states, "The locking device [shall be] readily distinguishable as locked." Item 2.2 states, "A readily visible durable sign [shall be] posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters I inch high on a contrasting background." 1 { Wall framing that has been covered without the benefit of inspection. City inspector will ask that gypsum wallboard be removed to verify wall framing and wall attachment to floor, it will be at the discretion of the City Inspector for how much gypsum wallboard to removed, only one side will be required to be removed. Do not remove any wallboard with out first having the 1 1 inspector on site ally shall be brace to structure above where eight feet in length or greater. . Exit illumination required: The means of egress, including the exit discharge, shall be \Jllurni11atcd at all times the building space served by the means of egress is occupied. l3. ashington State Energy Code 2018 C405.2.1 Occupant sensor controls. Occupant sensor controls shall be installed to con ii-ol lights in the following space types: 1. multipurpose rooms. 2. Lounge/breakrooms. 3. Enclosed offices. 4. Open plan office areas. 5. Restrooms. 6. Storage rooms. 7. Locker rooms. 8. Other spaces 300 square feet (28 m2 ) or less that are enclosed by flans -to- ceilin T hei =ht ar•titiotis. 114. 405.2.1.1 Occupant sensor control function. Occupant sensor controls shall comply with all of the following: 1. They shall be configured to automatically turn off lights within 20 minutes of all occupants leaving the space. 2. They shall be manual on or shall be configured to automatically turn the lighting on to not more than 50 percent power. Exception: Full automatic -on controls shall be permitted to control lighting in public corridors, stairways, restrooms, primary building entrance areas and lobbies, and areas where manual -on operation would endanger the safety or security of the room or building occupants. 3. They shall _ corporate a manual control to allow occupants to turn lights off. ,1S �.�lectrical permit required for the installation of Occupant sensor controls