21-104730-CO–Site PlanL
c�
N
U
I
LU
iy
I
c�
cB
W
N
IL
CO
O
a
(D
06
0
N
m
W
m
0
0
4
co
co
ti
g
U)
ca
0
C�
06
0
N
co
c>a
(B
N
N
H
m
O�
O
0
N
z
O
1--
(D
z
U)
U
N
0
n
U)
U
a�
U
U
O
v�
U
N
U
L
U)
O
O
N
0
U
0
U)
O
O
04
N
N
M
CM
6i
7—
N
0
N
N
N
O�
1ST FLOOR - SITE PLAN
Scale: 1 " = 10'-0"
KEYED NOTES #
1. NEW LANDSCAPE AREA.
2. ACCESSIBLE PATH OF TRAVEL.
3. NEW 6" CONCRETE CURB.
4. EXISTING CANOPY (ABOVE).
5. EXISTING GAS METER LOCATION.
6. EXISTING ELECTRICAL CABINET AND METER
LOCATION
7. EXISTING ELECTRICAL TRANSFORMER.
8. EXISTING SITE LIGHT POLE WITH LED LUMINAIRE.
9. NEW WHEEL STOPS.
10. MODIFIED TRASH ENCLOSURE.
11. RELOCATED DT CLEARANCE BAR ON NEW
CONCRETE FOOTING. GC TO VIF CONCRETE
FOOTING DOES NOT INTERFERE WITH MANHOLE.
12. PRE -MENU BOARD.
13. ORDER CANOPY, SCREEN, CONTROL BOX.
14. 5 PANEL MENU BOARD..
15. INSTALL DETECTOR LOOP AT DT ORDER POINT AND
DT WINDOW BY.
16. DT LANE GRAPHIC;TO BE THERMOGRAPHIC.
17. NON -ILLUMINATED BOLLARD.
18. PARKING STRIPING.
19. CUSTOM ONE SIDE DIRECTIONAL SIGN. ARROW AND
LOGO FACING THE DRIVE THRU. TO BE INSTALLED
ON EXISTING CONCRETE FOOTING.
20. STRIPING.
21. EXISTING MANHOLE COVER.
22. EXISTING STORM DRAIN.
23. NEW HANDICAP PARKING.
24. EXITING DT WAYFINDING GRAPHIC DIRECTIONAL
DOUBLE ARROW.
25. EXISTING DT WAYFINDING GRAPHIC EXIT ARROW.
26. EXISTING EXIT/THANKYOU DIRECTIONAL SIGN.
27. EXISTING MONUMENT SIGN.
GENERAL NOTES
A. REFER TO EXTERIOR ELEVATIONS ON SHEET A201
FOR BUILDING SIGNAGE LOCATION AND DESIGN ID.
REFER TO ELECTRICAL PLANS FOR ELECTRICAL
REQUIREMENTS.
B. LANDSCAPING TO BE PROVIDED PER ZONING CODE
AND SUSTAINABILITY REQUIREMENTS.
C. DRIVE-THRU EQUIPMENT INCLUDING VEHICLE
DETECTION LOOP, WIRELESS COMMUNICATION AND
MONITORS SHALL BE COORDINATED BY STARBUCKS
CONSTRUCTION MANAGER. REFER TO ELECTRICAL
DRAWINGS FOR ADDITIONAL REQUIREMENTS.
D. LANDLORD TO PROVIDE 6" (150MM) THICK CONCRETE
PAVING THE LENGTH OF THE DRIVE-THRU LANE,
EXTENT TO INCLUDE DRIVE-THRU ENTRY POINT
THROUGH WINDOW STANDING PAD.
E. GENERAL CONTRACTOR TO APPLY CONCRETE
SEALER TO ALL EXTERIOR CONCRETE PATIO AND
WALKWAY SURFACES.
F. GENERAL CONTRACTOR TO VERIFY ALL EXISTING
ELEVATIONS AND BUILDING CONDITIONS IN FIELD
PRIOR TO START OF CONSTRUCTION.
G. PROVIDE DETECTABLE WARNING (IF APPLCABLE PER
LOCAL CODE) AT TRANSITION FROM SIDEWALK TO
DRIVE AISLE.
H. ACCESSIBLE PARKING SPACES AND ACCESS AISLES
SHALL HAVE SURFACE SLOPE NOT TO EXCEED 2% IN
ALL DIRECTIONS.
I. REFER TO ELECTRICAL DRAWINGS FOR SITE
RELATED ELECTRICAL SLOPE.
J. SCRAPE AND REPAINT ALL EXISTING PAINTED SITE
FEATURES, INCLUDING, BUT NOT LIMITED TO CURBS,
BOLLARDS, RAILINGS AND SITE LIGHTING BASES.
K. SEE SHEET A002 FOR ARCHITECTURAL SITE
DETAILS.
LEGEND
NEW LANDSCAPE AREA
NEW CONCRETE WALKWAY
NEW 6" (150MM) CONCRETE CURB
CONCRETE DRIVE THRU LANE
----- ACCCESSIBLE PATH OF TRAVEL
0 10, 20' 40'
Scale: 1" = 20'-0"
r
N
Q
N
r
N
z
O
W
w
F_
W
0
F_
LL1
a.
0
m
J
a
z
LL
STARBVCKS®
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT BE
REPRODUCED (IN WHOLE OR IN PART), SHARED
WITH THIRD PARTIES OR USED IN ANY MANNER
ON OTHER PROJECTS OR EXTENSIONS TO THIS
PROJECT WITHOUT THE PRIOR WRITTEN
CONSENT OF STARBUCKS CORPORATION.
THESE DRAWINGS AND SPECIFICATIONS ARE
INTENDED TO EXPRESS DESIGN INTENT FOR A
PROTOTYPICAL STARBUCKS STORE (WHICH IS
SUBJECT TO CHANGE AT ANYTIME) AND DO NOT
REFLECT ACTUAL SITE CONDITIONS. NEITHER
PARTY SHALL HAVE ANY OBLIGATION NOR
LIABILITY TO THE OTHER (EXCEPT STATED
ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY
EXECUTED BY BOTH PARTIES.
STARBUCKS TEMPLATE VERSION 2020-04-20
ARCHITECT OF RECORD
SOOSOCIATES
Soos & Associates, Inc.
105 Schelter Road
Lincolnshire, IL 60069
p: 847 821 7667
RECEIVED
12/15/2021
CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
11883
REGIS RED
ECT
MELANIE S. SOQS
STATE OF WASHINGTON
VJ
LU
/ O
Q 00
O
Q
06 Q
J w Q
LU
= Q o OCV0 CV) � �
J
z Q Q O
� CN O W � U)W 0
LU 0 LU T- 0 (�
0 w 0 w z
STORE #:
52952
PROJECT #:
76634-009
ISSUE DATE:
09/10/2021
DESIGN MANAGER:
RYAN WONG
PRODUCTION DESIGNER:
SOOS
CHECKED BY:
SODS
Revision Schedule
ev Date By Description
8/26/21 CODE COMMENTS
9/10/21 DESIGN CHANGES
SHEET TITLE:
ARCHITECTURAL SITE
PLAN
SCALE: AS SHOWN
SHEET NUMBER:
A001