Loading...
19-102819. . �k. CITY OF == Federal Way R E C,F,-.�`tirED Eligible Facilities Request �l DEPARTMENT OF COMMUNITY DEVELOPMENT th =uU�'fii�i�iT 33325 8 Avenue South COMMUir Federal Way, WA 98003-6325 253-835-2607; Fax 253-835-2609 www,cItvoffedera I way. com FILE NUMBERJ - J - AD Date Applicant Applicant: T-Mobile Submitted by Amelia Meckler, Crown Castle 206-336-2863 1505 Westlake Ave N, Suite 800 ameIia.meckler@crowncastle.com COW A Seattle WA 98109 Site Address: 1628 S 344th ST aka 1622 433th ST Parcel #: 212104-9089 Project Name: 846423 Verizon New Colocation ELIGIBLE FACILITIES SUBMITTAL REQUIREMENTS Use this checklist to help gather all of the required information and documents in order to submit an eligible facilities request pursuant to Federal Way Revised Code (FWRC) 4.24.020. Please note, incomplete applications will not be accepted. Submitted Completed Eligible Facilities Checklist (following) Q� Check, cash, Visa/MasterCard for applicable fees Site Plan —Three Copies 1. Minimum plan size of 11" X 17". 2. North arrow. 3. Drawn to scale, dimensioned, and labeled. 4. Building footprint(s), including square footage. 5. Location and dimensions of existing structures, property lines, sidewalks, easements, street edges, mechanical equipment, fencing, rockeries, and retaining walls. Elevation —Three Copies 1. Minimum plan size of 11" x 17". 2. Drawn to scale, dimensioned, and labeled. 3. Front, rear, and side (labeled as north, south, east, and west) building elevation of existing and proposed structures. 4. Height of structure calculations. 5. Roof -top and ground based mechanical equipment screen details. Bulletin 081—September 24, 2018 Page 1 of 3 k:\Handouts\Eligible Facilities Request ELIGIBLE FACILITIES CHECKLIST Proposed modifications to an existing tower or base station must meet at least one of the three threshold criteria below for an eligible facilities request. For definitions please refer to FWRC 19.256.020. Check all that apply. Collocation of new transmission equipment Removal of transmission equipment Replacement of transmission equipment Is the proposed modification a substantial change as defined in FWRC 19.256.020? To determine, fill in the appropriate information below. If the application does not meet all of the criteria below, then the project does not qualify as an eligible facility and it is unnecessary to complete this form. To determine the correct review process, refer to FWRC Chapter 19.256, "Wireless Communication Facilities." Criteria 1 For towers other than towers in the public rights -of -way, it does not increase the height of the tower by more than 10 -percent, or by the height of one additional antenna array, with separation from the nearest existing antenna not to exceed 20 feet, whichever is greater. For other eligible support structures, it does not increase the height of the structure by more than 10 percent, or more than 10 feet, whichever is greater. Existing height of the structure: 100' (ft/ in) Proposed height of the structure: 100' (ft/ in) Distance of proposed array from nearest array: 20' (ft/ in) Criteria 2 For towers other than towers in the public rights -of -way, it does not involve adding an appurtenance to the body of the tower that would protrude from the edge of the tower more than 20 feet, or more than the width of the tower structure at the level of the appurtenance, whichever is greater. For other eligible support structures, it does not involve adding an appurtenance to the body of the structure that would protrude from the edge of the structure by more than six feet. What is the existing width of the structure at the level of the appurtenance? 6.65' (ft/ in) What is the proposed distance the appurtenance will protrude from the structure? aPP(nx 6' (<20) (ft/ in) Criteria 3 For any eligible support structure, it does not involve installation of more than the standard number of new equipment cabinets for the technology involved, but not to exceed four cabinets; or, , For towers in the public rights -of -way and base stations, it does not involve installation of any new equipment cabinets on the ground if there are no pre-existing ground cabinets associated with the structure; or It does not involve installation of ground cabinets that are more than 10 percent larger in height or overall volume, than any other ground cabinets associated with the structure. How many new equipment cabinets are proposed? 3 Bulletin 081—September 24, 2018 Page 2 of 3 k:\Handouts\Eligible Facilities Request 4 r Criteria 4 • For all existing facilities, it does not entail any excavation or deployment outside the current site. Will any excavation or equipment installation occur outside of the current site of the structure? ❑ Yes S/ No Criteria 5 For all existing facilities, the modification does not defeat the concealment elements of the eligible support structure. Please describe any existing and proposed concealment elements: none Will the proposal increase the visibility of the facility? ❑ Yes V No Criteria 6 The modification complies with conditions associated with the siting approval of the construction, or modification of the eligible support structure or base station equipment; provided, however, that this limitation does not apply to any modification that is noncompliant only in a manner that would not exceed the thresholds identified above. Identify known conditions associated with previous approvals of the existing facility. none known Will the proposal violate any of the above conditions? ❑ Yes 9f No If yes, explain: To Be Completed By Staff Is this an Eligible Facility Request? A Yes ❑ No Does the proposal constitute a substantial change? ❑ Yes l� No In accordance with FWRC 4.24.020, this application is hereby: Approved ❑ Denied f/ 2 ,/ 4 - 2 � - Z�1 '-'2' Director, Community Devet6pment Department Date Bulletin 081—September 24, 2018 Page 3 of 3 k:\Handouts\Eligible Facilities Request D VERIZON SLIM DESIGN FIRST TIME INSTALL veri onNp VERIZON ID: CR_SKATING_CENTER CROWN CASTLE PROJECT NAME: FEDERAL WAY CROWN CASTLE BU #: 846423 PROJECT LOCATION: 1628 SOUTH 344TH STREET FEDERAL WAY, WA 98003 APPLICATION #: 397495 VICINITY MAP I PROJECT INFORMATION �U@IN C� Rlfllll 0 � P311i46n A w�s1 $343te�1 9343��1 �161IegC�d� V4 g 16333 �3441hbY �3441h51 Man W0110 d 34191 Pl 134141 P1 �� CIvIa�CNaO H4151 PI 134141 PI 1101 Oo�mlymunily Chdleh W d N PROJECT 0101044 SITE N 9 8340& 33441h91 3Wm y klby� fmimdTeWaPlt:o � O�calnll'i� dale (� �� Q•FEdFte114dr,WA In Schwab The Carder0 wahan Supefeentelo I DRIVING DIRECTIONS (FROM SEA—TAC AIRPORT, WA) 1. TAKE RAMP RIGHT FOR WA-518 EAST TOWARD TACOMA / SEATTLE 2. TAKE RAMP RIGHT FOR I-5 SOUTH TOWARD TACOMA / PORTLAND 3. AT EXIT 1428, TAKE RAMP RIGHT AND FOLLOW SIGNS FOR WA-18 WEST 4. TURN RIGHT ONTO WA-161 ./ 16TH AVE S 5. TURN RIGHT ONTO S 344TH ST 330$& JURISDICTION: FEDERAL WAY ZONING CLASS: CE OCCUPANCY GROUP: UTILITY CONSTRUCTION TYPE: CO —LOCATE TAX PARCEL ID: 212104-9089 PARCEL SIZE: 2.08 ACRES LATITUDE: 47' 17' 39.33" LONGITUDE: —122' 18' 45.19" STRUCTURE HEIGHT: 100'-0- (TOP OF SELF—SUPPORT TOWER) LEASE AREA: 80 S.F. WITHIN AN EXISTING COMPOUND GREENFINGERS LLC 1628 S 344TH ST FEDERAL WAY, 98003 TOWER OPERATOR: CROWN CASTLE USA 1505 WESTLAKE AVE N, SUITE 800 SEATTLE, WA 98109 VERIZON CONTACT: TERESA BEARD VERIZON WIRELESS 3305 160TH AVE SE BELLEVUE. WA 98008 tereso.heard®verizonwireless.com I LEGAL DESCRIPTION I TRACTS 2 & 3 KING CO SHORT PLAT NO 876032 RECORDING NO 7609280733 (BEING A POR OF FOLG DESC POR SW QTR OF NW QTR STIR 21-21-04: S HALF SW QTR SW QTR NW QTR SD SEC 21 LESS N 150 FT OF W 200 FT; & LESS W 30 FT & S 30 FT FOR 16TH AVE S & S 344TH ST) -- AKA PARCEL A AS DELINEATED PER CITY OF FEDERAL WAY EOUNDARY LINE ADJUSTMENT NO BLA 91-0042 RECORDING NO 9212179007 APPROVE PLANNING City of Federal Way Dept. of Community Devekrpment Permit A!_ CO2SKI -► o ®y Date SCOPE OF WORK VERIZON WIRELESS PROPOSES TO INSTALL AN UNMANNED TELECOMMUNICATIONS FACILffY CONSISTING OF INS TALLATION STALLATION OF (6) NEW PANEL ANTENNAS, (3) 5G, (1) 2.0 MW DISH ANTENNA, (9) RRU'S, (2) HYBRID CABLES, (1) MW FEEDER AND (2) JUNCTION BOX ON A TRIPLE T—ARM ANTENNA MOUNT. ALSO PROPOSED IS THE INSTALLATION OF (3) EQUIPMENT CABINETS AND A H—FRAME WITHIN AN EXISTING FENCED COMPOUND AREA. LIST OF DRAWINGS SHEET DESCRIPTION T-1 COVER SHEET T-2 GENERAL NOTES AND SYMBOLS A-1 SITE PLAN A-1.1 COMPOUND AND EOUIPMENT PLANS A-2 ELEVATIONS A-3 CONSTRUCTION DETAILS A-4 CONSTRUCTION DETAILS RF-1 ANTENNA CONFIGURATION RF-2 PLUMBING DIAGRAM E-1 ELECTRICAL NOTES AND SYMBOLS E-2 ELECTRICAL SITE PLAN E-3 ELECTRICAL PLAN, NOTES, AND RISER DIAGRAM E-4 GROUNDING PLAN AND NOTES E-5 ELECTRICAL GROUNDING DETAILS & PANEL SCHEDULE E-6 ELECTRICAL & GROUNDING DETAILS E-7 ELECTRICAL & GROUNDING DETAILS RECEIVED PD NOT SCALE ORA*irfR- COIIiiNCTOW Wyt :'F.aM1T Ali aldElffiON9'AN9 AGtT6E CaeSULTAMS OF ART [itliflRS aR pY[SMRS- N� V,VrIATWNs OR Ar00A9LA11aNS TO waPK AAPRaY AIL PTHESaIAI 15 REV aF T MU%nNC JRE yyPERj£9EL BT THE 1ATESr R[VPU" ALL PU SON AND REW,WIA14 15 AE1WK WE PROVMtRRT1' or fI RERS1 _Rn [ A CaIEAORAToaf>, Ni7n1EN Y18 CON RUCTIONELa RLY THE THIS R JEC pRfi'1DINC CONSTRUCTION RLViEw OF THIS PROJECT. l CONSTRUCTION 05/22/19 ISSUED FOR PERMIT 04/24/19 5G ADDITION 10/19/17 ISSUED FOR PERMIT 08/16/17 IISSUED FOR REVIEW Dote 1 Revision verizonv �% CROWN � CASTLE 1505 WESTLAKE AVE N. SUITE S00 SEATTLE, WA 96109 M9 n MORRISON HERSHFIELD 600 STEWART ST, SUITE 200 SEATTLE, WA 98101 Tel: 206268 7370 www morrisonhelshfield-com JUI'1 11 2010 BU# 846423 I _ _ �+ r + { %� i-'"«�;�i`, 4,,, . ,'TZfrl _ ,. FEDERAL WAY 1628 SOUTH 344TH STREET FEDERAL WAY, WA 98003 CONTACTS CODE COMPLIANCE (Drawing Title: PAUL LONG CROWN CASTLE USA 1505 WESTLAKE AVE N, SUITE 800 SEATTLE, WA 98109 PHONE: 206.388.9090 APPLICANT CONTACT: CROWN CASTLE USA 1505 WESTLAKE AVE N, SUITE 800 SEATTLE, WA 98109 A&E CONTACT: ROY LORETE MORRISON HERSHFIELD CORP 600 STEWART ST. SUITE 200 SEATTLE, WA 98101 PHONE : (206) 268-7370 rlorete®morrisonhershfield.com ALL WORK AND MATERIALS SHALL BE PERFORMED AND. INSTALLED IN ACCOROANCE WON THE CURRENT CONOITK]NS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING ALTTIORmES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO IHESE CODES: WASHINGTON STATE AND LOCAL BUILDING CODES WITH THE FOLLOWING REFERENCE CODE: 2015 INTERNATIONAL BUILDING CODE (IBC) 2015 INTERNATIONAL MECHANICAL CODE (IMC) COVER SHEET 2015 INTERNATIONAL FIRE CODE (AFC) Project Number. 'Start Date: 2017 NATIONAL ELECTRIC CODE (NFPA 70) 1800386 108/1 1 /17 PROJECT MANAGER: CROWN CASTLE USA CROWNDSTLE 1505 WESTLAKE AVE N, SUITE 800 SEATTLE, WA 98109 JESSICA.DORRISOCROWNCASTLE.COM EMZ=NAL QE RECORID, ROBERT J LARD MORRISON HERSHFIELD CORP PHONE: (954) 577-4668 rlara®morrisonhershfield.com APPROVALS I)rafter: IRR Designer: LB SIGNATURE DATE Project Manager. RKL (Professional of RI IRL PROF CCIO el OF RECORD., REPRESENTATIVE Revision NO: SheeA NO: G. LANCE COOKE MORRISON HERSHFIELD CORP PHONE: (503) 595-9128 SITE OWNER T— 1 Icooke®morrisonhershfield.com RF ENGINEER I NOTE: THIS IS NOT A SURVEY. ALL INFORMATION AND TRUE NORTH HAVE BEEN OBTAINED FROM EXISTING DRAWINGS AND JURISDICTIONAL GIS INFORMATION AND ARE APPROXIMATE. I f f TAX PARCEL: 24-x36" SCALE 1- = 40'-0- 11-x17• SCALE: 1- = 80'-0- I I I 1 1 E ,7/; I4129600075 r % TAX PARCEL: r' 2121049017 ! TAX PARCEL: I 4129600070 I r•!i!/f�i/ff !//Ji ' '/ f Jfi/i i////i off /f/-�!/i ri firill/J/if.'!!• �iif.:' ' f i �f/i//! lJlfi/f/!/ :�/!/ ♦ t /f! //f!! � r /// t f/ / r iili! !/f/!f////ff/!/ f / / r t I ///!!/ f !f/f/� /f /f/ /f/J/f/ ///. /!!J/f/f///!!f////f/!//ff r'• I TAX PARCEL: 212104905-9 EXISTING ACCESS DRIVE I 4129600060 I t I ! TAX PARCEL: [[[l 4129600065 l I lTAX PARCEL: r I Itf/1+'Kjl}�iKlq*4_ii�f/i%i/%ff/��•] f f �. -i,/ %/i.i'i-:'r:r�•'r i%i. — --- — -- r EXISTING 100'-0" 'I i SELF—SUPPORT TOWER „� U i _ rIRVI I I E EXISTING FENCED COMPOUND 1e 81s All Z Iw f I� f w o. 1 I I i I if>a� k TAX PARCEL: 2121049089 ZONE: CEO ACRES : 2.08 ! ,F /. EXISTING BUILDING (TYP) � rtirlrlt/!iililflt�r�- TAX PARCEL: [ 2121049073 S 344TH STREET a 422.7 t 0CCASTLE I l Ti PARCEL: I TAX PARCEL: [ 2121049018 4129600045 [ f I 'TAX PARCEL: f I TAX PARCEL: 2121049073 TAX PARCEL / !/t 2500900040 2500900030 t 11 TAX PARCEL: 1 E ! 4129600055 I I "iAx PARCEL: 4129600050 1 n J 00 fl- ffff��ff i/flffi � Know what's be] Call before SITE PL ` ` N 00 NOT SCALE DRAWINGS. paRI6ACiaR MUST VERIFY ALL DIMENSIONS AND ADVISE 00161LL4iP OF ANY ERRORS OR owl ssnr�s. No vAlaAnns ae Moo�TlcAnus ro .lawc sHaWN sroei >� MP1E>'IENIED xmlaur PRIOR wRmE>t +IPPRCwV.L ALL PREHWS 5510 a5 11nS ORAA'ANO ARE SurlesEoto IN THE u1E57 r+En-qaN. Au oRA+rv+Gs la+D SPEOFYAiKl.`6 R[MNN i!a PRppER11' of waRRlsnN HER31FEL9 CORAaRV10H. NDn Al.-0 EXISTING COMPOUND �x. x x x x X X x x _x _x X X X---I x X r rfif !/rri rr r irr fii / fr•. r iif :; rr: r r. rf / :rf r/F r r X x / x EXISTING EQUIPMENT SHELTER F f x X (OF OTHERS) PROPOSED O WIRELESS72 / X X r T—ARM MOUNTMODELRjLTFO j BY SITEPRO 1 OR APPROVED EQUAL (IYP OF 3) x x q PROPOSED VERIZON ri EXISTING ICE BRIDGE WIRELESS GPS x x (OF OTHERS) ANTENNA MOUNTED * TO PROPOSED ICE X 10'-0" v f BRIDGE POST (SEE Y DETAIL 5/A-3) LEASE AREA/CONC. PAD PROPOSED VERIZON Y x r X WIRELESS ICE BRIDGE VERIZON -1 WIRELESS ANTENNAS +�+ CABLWESHAN2D (RMW 1GTxPROPOSED Y AND ANCILLARY FEEDER y, EQUIPMENT MOUNTED * ON NEW T-ARM MOUNT (TYP) C3 x = x U O � I d! `N \ M I _ x I 6 x I PROPOSED VERIZON m WIRELESS CONCRETE x PAD MOUNTED EQUIPMENT CABINET (TYP OF 3) X PROPOSED VERIZON WIRELESS q- UTILITY H-FRAME ,I x W/ WORK LIGHTS � I x EXISTING CHAIN LINK FENCE W/ 3-STRANDS OF BARBED WIRE ON TOP /y EXISTING 12'-0"' WIDE DOUBLE SWING GATE EXISTING ACCESS ROAD I x x x xl f x x x x X-X GENERATOR ON CONCRETE PAD r EXISTING UTILITY H-FRAME NOT • ONLY VERIZON WIRELESS ANTENNAS SHOWN IN PLAN VIEW FOR CLARITY; SEE ELEVATIONS 24'06- SCALE: 1/4- = 1'-0' 11"x17" SCALE 1/8- = 1'-0' i 3 2 1 0 4' 29'-C" EXISTING COMPOUND — I— I 1'-0. 7' z 0 0 a 0 PROPOSED VERIZON WIRELESS W8x15 STEEL I -BEAMS (TIP OF 2) 10'-0" LEASE AREA/CONC. PAD 5" r RADIO RADIO POWER & BATTERY n 7 'v \ � COMPOUND PLAN 1 2 , II-x17' �; 3/8" - 1:-0' V 6 0 1 PROPOSED VERIZON WIRELESS EQUIPMENT CABINET (TYP OF 3) PROPOSED VERIZON WIRELESS CONC PAD (8-0-x10-07 PROPOSED WORK UGHT (TYP OF 2) PROPOSED VERIZON WIRELESS UTILITY H-FRAME Do NOT SCALE 13FAWNOS CONTRAETOR MUST VERIFY ALL DIMENSIONS AND AME CONSULYAWIS OF AW ETA DR OMISSIONS. 110 WWIAPONS OR YOD6ICA'11ONS Ta *0W 90M SHALL NC uWLEMEf[TEO wmwllT PRR1R NlIITTEN APPRCNi. ALL PREL9Du� 6'J1E5 0& 11[S DRA11kiC ME SUPE(rraEDEO IN THE GTEST RMsaTI..M-L OR WMGS AND SPECIFIC11K1N5 REnVW THE PRaPERTY Di MaRR6C91 ARLIgTEC �jI%y � pRaV101�WR�5TRUC�OM�D REVIPr or THIS PnallEtT. I CONSTRUCTION `� a U 1 05/22/19 ISSUED FOR PERMIT is B 04/24/19 SG ADDITION 0 10/19/17 ISSUED FOR PERMIT A 08/16/17 ISSUED FOR REVIEW No. Date Revision Client: ►►erizon%/ PROPOSED EQUIPMENT PLAN 1 1 CROWN CASTLE 1505 WESTLAKE AVE N, SUITE 800 SEATTLE, WA 98109 A&E Team: n MORRISON HERSHFIELO 600 STEWART ST, SUITE 200 SEATTLE, WA 98101 Tel: 206 268. 7370 vnw+ morrisonhershfieldcom (Project Info: BU# 846423 FEDERAL WAY 1628 SOUTH 344TH STREET FEDERAL WAY, WA 98003 awing Title: COMPOUND AND EQUIPMENT PLANS croject Number. Start Date: 1800386 08/11/17 Drafter: Designer: RR ILB Project Manager: (Professional of Record: RKL IRL Revision No: FSheet No: I J. RA9 �E,N_TER tlF MSTING t 704 -O AGL T P F iSTIN F- t100 - ASL EXISTING ICE BRIDGE (OF OTHERS) EXISTING SHELTER (OF OTHERS) EXISTING CHAIN LINK FENCE W/ 3-STRANDS OF BARBED WIRE ON TOP NQ GRADE EXISTI 0'-0" AGL ASSUMEp NOTE- 1. NO WORK SHALL COMMENCE WITHOUT THE APPROVED TOWER STRUCTURAL ANALYSIS REPORT SIGNED AND SEALED BY A LICENSED PROFESSIONAL ENGINEER UNDER SEPARATE COVER. ANTENNA MOUNT DESIGN BY MANUFACTURER. 2. REFER TO ENGINEERED DRAWINGS FOR DESIGN/ENGINEERING OF MONOPOLE AND ITS FOUNDATION BY TOWER MANUFACTURER. 3. PROPOSED ANTENNA MOUNTS SHALL COMPLY WITH NSTD-445 STANDARDS AS REQUIRED BY VERIZON. IT NERATOR ) C HTER OF N A NNAS t 10d -O AGL i0p 1 �xIZING SE f-SUPPORT TOWER t 100 -0 ~AGL TIP OF PROPOSED VERIZON tL��-0 AGL,j AN1T�r1AS 87 RAD CENTER OF PROPOSED VERRON WIRELESS ANTENNAS Y t84.-0' AGL RAID CENTER OF PROPOSED VERIZON MW to t77 -O AGL EXISTING ICE BRIDGE (OF OTHERS) EXISTING SHELTER (OF OTHERS) EXISTING CHAIN LINK FENCE W/ 3-STRANDS OF BARBED WIRE ON TOP �,�xIST11,IG GRADE `>• D -0' AG AL�SSMU fD EXISTING ANTENNA ARRAY (OF OTHERS) PROPOSED VERIZON WIRELESS T-ARM MOUNT MODEL / LTF 10-372 BY SITEPRO 1 OR APPROVED EQUAL (TYP OF 3) PROPOSED VERIZON WIRELESS ANTENNAS AND ANCILLARY EQUIPMENT MOUNTED ON NEW T-ARM MOUNT (TYP) PROPOSED VERIZON WIRELESS 2.0 MW DISH ANTENNA EXISTING STAND-OFF MOUNT (OF OTHERS) PROPOSED VERIZON WIRELESS FEEDUNES [(1) HYBRID CABLE, (1) MW FEEDER ROUTED ALONG THE SELF-SUPPORT TOWER EXISTING 100'-0" SELF-SUPPORT TOWER PROPOSED VERIZON WIRELESS ICE BRIDGE WITH (1) HYBRID CABLE AND (1) MW FEEDER PROPOSED VERIZON WIRELESS GPS ANTENNA MOUNTED ON ICE BRIDGE POST PROPOSED VERIZON WIRELESS CONCRETE PAD MOUNTED EQUIPMENT CABINET (TYP OF 3) EXISTING GENERATOR (OF OTHERS) PROPOSED VERIZON WIRELESS UTILITY H-FRAME W/ WORK LIGHTS PROPOSED VERIZON WIRELESS GONG PAD (8'-O'X1O'-07 W NOT SCALE DAWNC$. CONTRACTOR ✓JU51 YERITI' ALL m WWRS AM AOV15[ OiVf LTA n OF — ERRIM aA ou6S10%e. no VA "PIONS OR LODT/GSTIOR% TO WORK APPAOVNN.. A PRD1IX4 ISSUES OF TMG DRAXINCt AK Sffl SfOEO BY TW LATESr WMS104. ALL DRA1 CA A+m SIEMHF 1�ATMICORROIAPON. 1T1't4ft Moffi Ss N IZ�RSHA" NOR THE A HIITIMT YAu. 6i PRWDING COHSTRIIGTWN RENEW OF IRIS PROJECT. I CONSTRUCTION I 1 1 05/22/19 ISSUED FOR PERMIT B 04/24/19 5G ADDITION 0 10/19/17 ISSUED FOR PERMIT A 08/16/17 ISSUED FOR REVIEW No. Date Revision verizonv nentotion Team: CROWN CASTLE 1505 WESTLAKE AVE N, SUITE 800 SEATTLE, WA 98109 M.9 n MORRISON HERSHFIELD 600 STEWART ST, SUITE 200 SEATTLE, WA 98101 Tel: 206.268,7370 —,monies he hfield.com BU# 846423 FEDERAL WAY 1628 SOUTH 344TH STREET FEDERAL WAY, WA 98DO3 Title: ELEVATIONS Project Number 'Start Date: 1800386 08/11/17 Drafter: Designer. RR LB Project Manager. (Professional of Recortl: IRKL IRL Reriaian No: Sheet No: wwj 24'x36' SCALE 1/8' = V-0' 11'x17' SCALE. 1/16' = 1'-0' X V 4 2 D EXISTING ELEVATION ` 2 11-xl7= Ste` 1/16' ='1' 0' PROPOSED ELEVATION 11 CCCROWN CASTLE June 11, 2019 CITY OF FEDERAL WAY DEPARTMENT OF COMMUNITY DEVELOPMENT 33325 8th Avenue South Federal Way, WA 98003-6325 1505 Westlake Ave N Seattle, WA 98109 RE: Eligible Facilities Request to modify equipment on a communications tower located at: 1622 SOUTH 344TH STREET, FEDERAL WAY, WA, 98003 (aka 1628 S 34411' ST) Crown Site Number: 846423 / Crown Site Name: FEDERAL WAY Customer Site Number: CR_SKATING_CENTER / Application Number: 476495 Phone:(206) 336-2863 Fax: www.crowncastle.com Crown Castle USA Inc. ("Crown Castle") on behalf of Seattle SMSA Limited Partnership ("Verizon Wireless") is submitting the attached Eligible Facilities Request application to add transmission equipment on a telecommunications tower located at 1622 SOUTH 344TH STREET, FEDERAL WAY, WA 98003 in CITY OF FEDERAL WAY, WA (the "FEDERAL WAY Tower"). Section 6409 of the Middle Class Tax Relief and Job Creation Act of 2012, commonly known as the "Spectrum Act" (Pub. Law No. 112-96,126 Stat 156), mandates that state and local governments "may not deny, and shall approve, any eligible facilities request for a modification of an existing wireless tower or base station that does not substantially change the physical dimensions of such tower or base station." Additionally, if "the reviewing State or local government determines that the application is incomplete" [they] "must provide written notice to the applicant within 3o days of receipt of the application, clearly and specifically delineating all missing documents or information." Under federal law, an Eligible Facilities Request is deemed granted with written notification in sixty (60) days after an application is filed with a local jurisdiction, excluding tolling. Based on the submittal date of June 11, 2019, 3o days will expire on July 11, 2019; 6o days will expire on August 10, 2019. Verizon Wireless proposes to modify the "FEDERAL WAY Tower" as follows: New colocation of (9) Antennas (1) MW Antenna (9) RRU (2) Junction boxes New mounts Ancillary equipment and lines (3) Equipment Cabinet on concrete pad (1) H-frame (1) Ice Bridge The Foundation for a Wireless World. CrownCastlexom CROWN 1505 Westlake Ave N Phone: (206) 336-2663 Seattle, WA 98109 Fax: C C%MO CASTLE www.crowncastle.com Itemized list of submittal documents: EFR Application (3) Copies of Site Plan and Elevations Check 29772 for $141.00 Verizon Wireless is committed to working cooperatively with all jurisdictions around the country to secure expeditious approval of requests to modify existing personal wireless service facilities. If you should require more information regarding the Spectrum Act, please do not hesitate to contact me with your questions. Sincerely, ,At qxkv�� Amelia Medder Amelia.Meckler@crowncastle.com (2o6) 336-2863 The Foundation for a Wireless World. CrownCastlexom