19-102819. . �k.
CITY OF ==
Federal Way
R E C,F,-.�`tirED
Eligible Facilities Request
�l DEPARTMENT OF COMMUNITY DEVELOPMENT
th
=uU�'fii�i�iT 33325 8 Avenue South
COMMUir Federal Way, WA 98003-6325
253-835-2607; Fax 253-835-2609
www,cItvoffedera I way. com
FILE NUMBERJ - J - AD Date
Applicant
Applicant: T-Mobile Submitted by Amelia Meckler, Crown Castle 206-336-2863
1505 Westlake Ave N, Suite 800 ameIia.meckler@crowncastle.com
COW A
Seattle WA 98109
Site Address: 1628 S 344th ST aka 1622 433th ST
Parcel #: 212104-9089
Project Name: 846423 Verizon New Colocation
ELIGIBLE FACILITIES SUBMITTAL REQUIREMENTS
Use this checklist to help gather all of the required information and documents in order to submit an eligible
facilities request pursuant to Federal Way Revised Code (FWRC) 4.24.020. Please note, incomplete applications
will not be accepted.
Submitted
Completed Eligible Facilities Checklist (following)
Q�
Check, cash, Visa/MasterCard for applicable fees
Site Plan —Three Copies
1. Minimum plan size of 11" X 17".
2. North arrow.
3. Drawn to scale, dimensioned, and labeled.
4. Building footprint(s), including square footage.
5. Location and dimensions of existing structures, property lines, sidewalks, easements, street
edges, mechanical equipment, fencing, rockeries, and retaining walls.
Elevation —Three Copies
1. Minimum plan size of 11" x 17".
2. Drawn to scale, dimensioned, and labeled.
3. Front, rear, and side (labeled as north, south, east, and west) building elevation of existing
and proposed structures.
4. Height of structure calculations.
5. Roof -top and ground based mechanical equipment screen details.
Bulletin 081—September 24, 2018 Page 1 of 3 k:\Handouts\Eligible Facilities Request
ELIGIBLE FACILITIES CHECKLIST
Proposed modifications to an existing tower or base station must meet at least one of the three threshold criteria
below for an eligible facilities request. For definitions please refer to FWRC 19.256.020. Check all that apply.
Collocation of new transmission equipment
Removal of transmission equipment
Replacement of transmission equipment
Is the proposed modification a substantial change as defined in FWRC 19.256.020? To determine, fill in the
appropriate information below. If the application does not meet all of the criteria below, then the project does
not qualify as an eligible facility and it is unnecessary to complete this form. To determine the correct review
process, refer to FWRC Chapter 19.256, "Wireless Communication Facilities."
Criteria 1
For towers other than towers in the public rights -of -way, it does not increase the height of the tower by more
than 10 -percent, or by the height of one additional antenna array, with separation from the nearest existing
antenna not to exceed 20 feet, whichever is greater.
For other eligible support structures, it does not increase the height of the structure by more than 10 percent,
or more than 10 feet, whichever is greater.
Existing height of the structure: 100' (ft/ in) Proposed height of the structure: 100' (ft/ in)
Distance of proposed array from nearest array: 20' (ft/ in)
Criteria 2
For towers other than towers in the public rights -of -way, it does not involve adding an appurtenance to the
body of the tower that would protrude from the edge of the tower more than 20 feet, or more than the width
of the tower structure at the level of the appurtenance, whichever is greater.
For other eligible support structures, it does not involve adding an appurtenance to the body of the structure
that would protrude from the edge of the structure by more than six feet.
What is the existing width of the structure at the level of the appurtenance? 6.65' (ft/ in)
What is the proposed distance the appurtenance will protrude from the structure? aPP(nx 6' (<20) (ft/ in)
Criteria 3
For any eligible support structure, it does not involve installation of more than the standard number of new
equipment cabinets for the technology involved, but not to exceed four cabinets; or, ,
For towers in the public rights -of -way and base stations, it does not involve installation of any new equipment
cabinets on the ground if there are no pre-existing ground cabinets associated with the structure; or
It does not involve installation of ground cabinets that are more than 10 percent larger in height or overall
volume, than any other ground cabinets associated with the structure.
How many new equipment cabinets are proposed? 3
Bulletin 081—September 24, 2018 Page 2 of 3 k:\Handouts\Eligible Facilities Request
4
r
Criteria 4
• For all existing facilities, it does not entail any excavation or deployment outside the current site.
Will any excavation or equipment installation occur outside of the current site of the structure?
❑ Yes S/ No
Criteria 5
For all existing facilities, the modification does not defeat the concealment elements of the eligible support
structure.
Please describe any existing and proposed concealment elements:
none
Will the proposal increase the visibility of the facility? ❑ Yes V No
Criteria 6
The modification complies with conditions associated with the siting approval of the construction, or
modification of the eligible support structure or base station equipment; provided, however, that this
limitation does not apply to any modification that is noncompliant only in a manner that would not exceed
the thresholds identified above.
Identify known conditions associated with previous approvals of the existing facility.
none known
Will the proposal violate any of the above conditions? ❑ Yes 9f No
If yes, explain:
To Be Completed By Staff
Is this an Eligible Facility Request? A Yes ❑ No
Does the proposal constitute a substantial change? ❑ Yes l� No
In accordance with FWRC 4.24.020, this application is hereby:
Approved ❑ Denied
f/ 2 ,/ 4 - 2 � - Z�1 '-'2'
Director, Community Devet6pment Department Date
Bulletin 081—September 24, 2018 Page 3 of 3 k:\Handouts\Eligible Facilities Request
D
VERIZON SLIM DESIGN FIRST TIME INSTALL
veri onNp
VERIZON ID: CR_SKATING_CENTER
CROWN CASTLE PROJECT NAME: FEDERAL WAY
CROWN CASTLE BU #: 846423
PROJECT LOCATION: 1628 SOUTH 344TH STREET
FEDERAL WAY, WA 98003
APPLICATION #: 397495
VICINITY MAP I PROJECT INFORMATION
�U@IN C� Rlfllll 0
� P311i46n A w�s1
$343te�1 9343��1 �161IegC�d�
V4 g
16333
�3441hbY �3441h51
Man W0110
d 34191 Pl 134141 P1 ��
CIvIa�CNaO
H4151 PI 134141 PI
1101
Oo�mlymunily Chdleh
W
d
N
PROJECT
0101044 SITE
N
9
8340& 33441h91 3Wm
y klby� fmimdTeWaPlt:o
� O�calnll'i� dale (�
�� Q•FEdFte114dr,WA
In Schwab The Carder0 wahan Supefeentelo
I DRIVING DIRECTIONS
(FROM SEA—TAC AIRPORT, WA)
1. TAKE RAMP RIGHT FOR WA-518 EAST TOWARD TACOMA / SEATTLE
2. TAKE RAMP RIGHT FOR I-5 SOUTH TOWARD TACOMA / PORTLAND
3. AT EXIT 1428, TAKE RAMP RIGHT AND FOLLOW SIGNS FOR WA-18 WEST
4. TURN RIGHT ONTO WA-161 ./ 16TH AVE S
5. TURN RIGHT ONTO S 344TH ST
330$&
JURISDICTION:
FEDERAL WAY
ZONING CLASS:
CE
OCCUPANCY GROUP:
UTILITY
CONSTRUCTION TYPE:
CO —LOCATE
TAX PARCEL ID:
212104-9089
PARCEL SIZE:
2.08 ACRES
LATITUDE:
47' 17' 39.33"
LONGITUDE:
—122' 18' 45.19"
STRUCTURE HEIGHT:
100'-0- (TOP OF SELF—SUPPORT TOWER)
LEASE AREA:
80 S.F. WITHIN AN EXISTING COMPOUND
GREENFINGERS LLC
1628 S 344TH ST
FEDERAL WAY, 98003
TOWER OPERATOR:
CROWN CASTLE USA
1505 WESTLAKE AVE N, SUITE 800
SEATTLE, WA 98109
VERIZON CONTACT:
TERESA BEARD
VERIZON WIRELESS
3305 160TH AVE SE
BELLEVUE. WA 98008
tereso.heard®verizonwireless.com
I LEGAL DESCRIPTION I
TRACTS 2 & 3 KING CO SHORT PLAT NO 876032 RECORDING NO 7609280733 (BEING A POR OF FOLG DESC POR SW QTR OF NW QTR
STIR 21-21-04: S HALF SW QTR SW QTR NW QTR SD SEC 21 LESS N 150 FT OF W 200 FT; & LESS W 30 FT & S 30 FT FOR 16TH
AVE S & S 344TH ST) -- AKA PARCEL A AS DELINEATED PER CITY OF FEDERAL WAY EOUNDARY LINE ADJUSTMENT NO BLA 91-0042
RECORDING NO 9212179007
APPROVE
PLANNING
City of Federal Way
Dept. of Community Devekrpment
Permit A!_ CO2SKI -► o
®y
Date
SCOPE OF WORK
VERIZON WIRELESS PROPOSES TO INSTALL AN UNMANNED TELECOMMUNICATIONS FACILffY CONSISTING OF
INS
TALLATION STALLATION OF (6) NEW PANEL ANTENNAS, (3) 5G, (1) 2.0 MW DISH ANTENNA, (9) RRU'S, (2)
HYBRID CABLES, (1) MW FEEDER AND (2) JUNCTION BOX ON A TRIPLE T—ARM ANTENNA MOUNT. ALSO
PROPOSED IS THE INSTALLATION OF (3) EQUIPMENT CABINETS AND A H—FRAME WITHIN AN EXISTING
FENCED COMPOUND AREA.
LIST OF DRAWINGS
SHEET DESCRIPTION
T-1 COVER SHEET
T-2 GENERAL NOTES AND SYMBOLS
A-1 SITE PLAN
A-1.1 COMPOUND AND EOUIPMENT PLANS
A-2 ELEVATIONS
A-3 CONSTRUCTION DETAILS
A-4 CONSTRUCTION DETAILS
RF-1 ANTENNA CONFIGURATION
RF-2 PLUMBING DIAGRAM
E-1 ELECTRICAL NOTES AND SYMBOLS
E-2 ELECTRICAL SITE PLAN
E-3 ELECTRICAL PLAN, NOTES, AND RISER DIAGRAM
E-4 GROUNDING PLAN AND NOTES
E-5 ELECTRICAL GROUNDING DETAILS & PANEL SCHEDULE
E-6 ELECTRICAL & GROUNDING DETAILS
E-7 ELECTRICAL & GROUNDING DETAILS RECEIVED
PD NOT SCALE ORA*irfR- COIIiiNCTOW Wyt :'F.aM1T Ali
aldElffiON9'AN9 AGtT6E CaeSULTAMS OF ART [itliflRS aR
pY[SMRS- N� V,VrIATWNs OR Ar00A9LA11aNS TO waPK
AAPRaY AIL PTHESaIAI 15 REV aF T MU%nNC JRE
yyPERj£9EL BT THE 1ATESr R[VPU" ALL PU SON AND
REW,WIA14 15 AE1WK WE PROVMtRRT1' or fI RERS1
_Rn [ A CaIEAORAToaf>, Ni7n1EN Y18 CON RUCTIONELa
RLY THE THIS R JEC pRfi'1DINC CONSTRUCTION
RLViEw OF THIS PROJECT.
l CONSTRUCTION
05/22/19 ISSUED FOR PERMIT
04/24/19 5G ADDITION
10/19/17 ISSUED FOR PERMIT
08/16/17 IISSUED FOR REVIEW
Dote 1 Revision
verizonv
�% CROWN
� CASTLE
1505 WESTLAKE AVE N. SUITE S00
SEATTLE, WA 96109
M9
n
MORRISON HERSHFIELD
600 STEWART ST, SUITE 200
SEATTLE, WA 98101
Tel: 206268 7370
www morrisonhelshfield-com
JUI'1 11 2010
BU# 846423
I _ _
�+
r + { %� i-'"«�;�i`, 4,,, .
,'TZfrl _ ,.
FEDERAL WAY
1628 SOUTH 344TH STREET
FEDERAL WAY, WA 98003
CONTACTS
CODE COMPLIANCE
(Drawing Title:
PAUL LONG
CROWN CASTLE USA
1505 WESTLAKE AVE N, SUITE 800
SEATTLE, WA 98109
PHONE: 206.388.9090
APPLICANT CONTACT:
CROWN CASTLE USA
1505 WESTLAKE AVE N, SUITE 800
SEATTLE, WA 98109
A&E CONTACT:
ROY LORETE
MORRISON HERSHFIELD CORP
600 STEWART ST. SUITE 200
SEATTLE, WA 98101
PHONE : (206) 268-7370
rlorete®morrisonhershfield.com
ALL WORK AND MATERIALS SHALL BE PERFORMED AND. INSTALLED IN ACCOROANCE WON THE CURRENT
CONOITK]NS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING ALTTIORmES. NOTHING
IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO IHESE CODES:
WASHINGTON STATE AND LOCAL BUILDING CODES WITH THE FOLLOWING REFERENCE CODE:
2015 INTERNATIONAL BUILDING CODE (IBC)
2015 INTERNATIONAL MECHANICAL CODE (IMC)
COVER
SHEET
2015 INTERNATIONAL FIRE CODE (AFC)
Project Number. 'Start Date:
2017 NATIONAL ELECTRIC CODE (NFPA 70)
1800386 108/1 1 /17
PROJECT MANAGER:
CROWN CASTLE USA
CROWNDSTLE
1505 WESTLAKE AVE N, SUITE 800
SEATTLE, WA 98109
JESSICA.DORRISOCROWNCASTLE.COM
EMZ=NAL QE RECORID,
ROBERT J LARD
MORRISON HERSHFIELD CORP
PHONE: (954) 577-4668
rlara®morrisonhershfield.com
APPROVALS
I)rafter:
IRR
Designer:
LB
SIGNATURE
DATE
Project Manager.
RKL
(Professional of RI
IRL
PROF CCIO el OF RECORD.,
REPRESENTATIVE
Revision NO:
SheeA NO:
G. LANCE COOKE
MORRISON HERSHFIELD CORP
PHONE: (503) 595-9128
SITE OWNER
T— 1
Icooke®morrisonhershfield.com
RF ENGINEER
I
NOTE:
THIS IS NOT A SURVEY. ALL INFORMATION AND TRUE NORTH
HAVE BEEN OBTAINED FROM EXISTING DRAWINGS AND
JURISDICTIONAL GIS INFORMATION AND ARE APPROXIMATE.
I f f
TAX PARCEL:
24-x36" SCALE 1- = 40'-0-
11-x17• SCALE: 1- = 80'-0-
I
I
I
1
1
E
,7/;
I4129600075
r
%
TAX PARCEL:
r'
2121049017
!
TAX PARCEL: I
4129600070 I
r•!i!/f�i/ff !//Ji ' '/ f Jfi/i i////i
off /f/-�!/i ri firill/J/if.'!!• �iif.:' '
f
i �f/i//! lJlfi/f/!/ :�/!/ ♦ t /f! //f!! � r /// t f/ / r iili! !/f/!f////ff/!/
f /
/
r
t
I ///!!/ f !f/f/� /f /f/ /f/J/f/ ///. /!!J/f/f///!!f////f/!//ff r'•
I
TAX PARCEL:
212104905-9
EXISTING ACCESS DRIVE
I 4129600060
I
t I
! TAX PARCEL:
[[[l 4129600065
l I
lTAX PARCEL: r
I
Itf/1+'Kjl}�iKlq*4_ii�f/i%i/%ff/��•] f f �. -i,/ %/i.i'i-:'r:r�•'r i%i. — --- — --
r EXISTING 100'-0" 'I
i SELF—SUPPORT TOWER „� U
i _ rIRVI I
I E EXISTING FENCED COMPOUND
1e 81s All
Z
Iw
f I�
f w o.
1
I
I
i
I
if>a�
k
TAX PARCEL:
2121049089
ZONE: CEO
ACRES : 2.08
! ,F /. EXISTING BUILDING (TYP)
� rtirlrlt/!iililflt�r�-
TAX PARCEL: [
2121049073
S 344TH STREET
a
422.7
t
0CCASTLE
I
l
Ti PARCEL: I TAX PARCEL: [
2121049018 4129600045 [
f I 'TAX PARCEL: f I TAX PARCEL:
2121049073
TAX PARCEL / !/t 2500900040
2500900030
t
11
TAX PARCEL: 1
E !
4129600055
I
I
"iAx PARCEL:
4129600050
1
n
J
00
fl-
ffff��ff i/flffi �
Know what's be]
Call before
SITE PL
`
`
N
00 NOT SCALE DRAWINGS. paRI6ACiaR MUST VERIFY ALL
DIMENSIONS AND ADVISE 00161LL4iP OF ANY ERRORS OR
owl ssnr�s. No vAlaAnns ae Moo�TlcAnus ro .lawc
sHaWN sroei >� MP1E>'IENIED xmlaur PRIOR wRmE>t
+IPPRCwV.L ALL PREHWS 5510 a5 11nS ORAA'ANO ARE
SurlesEoto IN THE u1E57 r+En-qaN. Au oRA+rv+Gs la+D
SPEOFYAiKl.`6 R[MNN i!a PRppER11' of waRRlsnN
HER31FEL9 CORAaRV10H. NDn
Al.-0
EXISTING COMPOUND
�x.
x
x x
x X X x x _x
_x X
X
X---I
x
X
r rfif !/rri rr r irr fii / fr•. r iif :; rr: r r. rf / :rf r/F r r
X
x
/
x
EXISTING EQUIPMENT SHELTER
F
f
x
X
(OF OTHERS)
PROPOSED O WIRELESS72
/
X
X
r
T—ARM MOUNTMODELRjLTFO
j
BY SITEPRO 1 OR APPROVED EQUAL
(IYP OF 3)
x
x
q
PROPOSED VERIZON
ri
EXISTING ICE BRIDGE
WIRELESS GPS
x
x
(OF OTHERS)
ANTENNA MOUNTED
*
TO PROPOSED ICE
X
10'-0"
v
f
BRIDGE POST (SEE
Y
DETAIL 5/A-3)
LEASE AREA/CONC. PAD
PROPOSED VERIZON
Y
x r
X
WIRELESS ICE BRIDGE
VERIZON -1
WIRELESS ANTENNAS +�+
CABLWESHAN2D (RMW
1GTxPROPOSED
Y
AND ANCILLARY
FEEDER
y,
EQUIPMENT MOUNTED
*
ON NEW T-ARM
MOUNT (TYP)
C3
x
=
x
U
O �
I
d!
`N
\
M
I
_
x
I
6
x
I
PROPOSED VERIZON m
WIRELESS CONCRETE
x
PAD MOUNTED
EQUIPMENT CABINET
(TYP OF 3)
X
PROPOSED
VERIZON WIRELESS
q-
UTILITY H-FRAME ,I
x
W/ WORK LIGHTS
�
I
x
EXISTING CHAIN LINK
FENCE W/
3-STRANDS OF
BARBED WIRE ON TOP
/y
EXISTING 12'-0"'
WIDE DOUBLE
SWING GATE
EXISTING ACCESS
ROAD
I
x
x
x xl f
x x x x X-X
GENERATOR ON
CONCRETE PAD
r EXISTING UTILITY H-FRAME
NOT •
ONLY VERIZON WIRELESS ANTENNAS SHOWN IN PLAN VIEW FOR CLARITY; SEE ELEVATIONS
24'06- SCALE: 1/4- = 1'-0'
11"x17" SCALE 1/8- = 1'-0' i 3 2 1 0 4'
29'-C"
EXISTING COMPOUND
— I—
I 1'-0. 7'
z
0
0
a
0
PROPOSED VERIZON
WIRELESS W8x15 STEEL
I -BEAMS (TIP OF 2)
10'-0"
LEASE AREA/CONC. PAD
5"
r
RADIO RADIO
POWER &
BATTERY
n
7
'v
\ �
COMPOUND PLAN 1 2 , II-x17' �; 3/8" - 1:-0' V 6 0 1
PROPOSED VERIZON
WIRELESS EQUIPMENT
CABINET (TYP OF 3)
PROPOSED VERIZON
WIRELESS CONC PAD
(8-0-x10-07
PROPOSED WORK UGHT
(TYP OF 2)
PROPOSED VERIZON
WIRELESS UTILITY H-FRAME
Do NOT SCALE 13FAWNOS CONTRAETOR MUST VERIFY ALL
DIMENSIONS AND AME CONSULYAWIS OF AW ETA DR
OMISSIONS. 110 WWIAPONS OR YOD6ICA'11ONS Ta *0W
90M SHALL NC uWLEMEf[TEO wmwllT PRR1R NlIITTEN
APPRCNi. ALL PREL9Du� 6'J1E5 0& 11[S DRA11kiC ME
SUPE(rraEDEO IN THE GTEST RMsaTI..M-L OR WMGS AND
SPECIFIC11K1N5 REnVW THE PRaPERTY Di MaRR6C91
ARLIgTEC �jI%y � pRaV101�WR�5TRUC�OM�D
REVIPr or THIS PnallEtT.
I CONSTRUCTION
`�
a
U
1 05/22/19 ISSUED FOR PERMIT
is B 04/24/19 SG ADDITION
0 10/19/17 ISSUED FOR PERMIT
A 08/16/17 ISSUED FOR REVIEW
No. Date Revision
Client:
►►erizon%/
PROPOSED EQUIPMENT PLAN 1 1
CROWN
CASTLE
1505 WESTLAKE AVE N, SUITE 800
SEATTLE, WA 98109
A&E Team:
n
MORRISON HERSHFIELO
600 STEWART ST, SUITE 200
SEATTLE, WA 98101
Tel: 206 268. 7370
vnw+ morrisonhershfieldcom
(Project Info:
BU# 846423
FEDERAL WAY
1628 SOUTH 344TH STREET
FEDERAL WAY, WA 98003
awing Title:
COMPOUND AND
EQUIPMENT PLANS
croject Number.
Start Date:
1800386
08/11/17
Drafter:
Designer:
RR
ILB
Project Manager:
(Professional of Record:
RKL
IRL
Revision No:
FSheet No:
I
J. RA9 �E,N_TER tlF MSTING
t 704 -O AGL
T P F iSTIN F-
t100 - ASL
EXISTING ICE BRIDGE (OF
OTHERS)
EXISTING SHELTER (OF
OTHERS)
EXISTING CHAIN LINK
FENCE W/ 3-STRANDS
OF BARBED WIRE ON TOP
NQ GRADE
EXISTI
0'-0" AGL ASSUMEp
NOTE-
1. NO WORK SHALL COMMENCE WITHOUT THE APPROVED TOWER
STRUCTURAL ANALYSIS REPORT SIGNED AND SEALED BY A
LICENSED PROFESSIONAL ENGINEER UNDER SEPARATE COVER.
ANTENNA MOUNT DESIGN BY MANUFACTURER.
2. REFER TO ENGINEERED DRAWINGS FOR DESIGN/ENGINEERING
OF MONOPOLE AND ITS FOUNDATION BY TOWER
MANUFACTURER.
3. PROPOSED ANTENNA MOUNTS SHALL COMPLY WITH NSTD-445
STANDARDS AS REQUIRED BY VERIZON.
IT
NERATOR
)
C HTER OF N A NNAS
t 10d -O AGL
i0p 1 �xIZING SE f-SUPPORT TOWER
t 100 -0 ~AGL
TIP OF PROPOSED VERIZON
tL��-0 AGL,j AN1T�r1AS
87
RAD CENTER OF PROPOSED
VERRON WIRELESS ANTENNAS
Y t84.-0' AGL
RAID CENTER OF PROPOSED VERIZON
MW to
t77 -O AGL
EXISTING ICE BRIDGE (OF
OTHERS)
EXISTING SHELTER (OF
OTHERS)
EXISTING CHAIN LINK
FENCE W/ 3-STRANDS
OF BARBED WIRE ON TOP
�,�xIST11,IG GRADE
`>• D -0' AG AL�SSMU fD
EXISTING ANTENNA ARRAY
(OF OTHERS)
PROPOSED VERIZON WIRELESS
T-ARM MOUNT MODEL / LTF 10-372
BY SITEPRO 1 OR APPROVED EQUAL
(TYP OF 3)
PROPOSED VERIZON WIRELESS
ANTENNAS AND ANCILLARY
EQUIPMENT MOUNTED ON NEW
T-ARM MOUNT (TYP)
PROPOSED VERIZON WIRELESS
2.0 MW DISH ANTENNA
EXISTING STAND-OFF
MOUNT (OF OTHERS)
PROPOSED VERIZON WIRELESS
FEEDUNES [(1) HYBRID CABLE,
(1) MW FEEDER ROUTED ALONG
THE SELF-SUPPORT TOWER
EXISTING 100'-0"
SELF-SUPPORT TOWER
PROPOSED VERIZON WIRELESS
ICE BRIDGE WITH (1) HYBRID
CABLE AND (1) MW FEEDER
PROPOSED VERIZON WIRELESS
GPS ANTENNA MOUNTED ON ICE
BRIDGE POST
PROPOSED VERIZON WIRELESS
CONCRETE PAD MOUNTED
EQUIPMENT CABINET (TYP OF 3)
EXISTING GENERATOR
(OF OTHERS)
PROPOSED VERIZON WIRELESS
UTILITY H-FRAME W/ WORK LIGHTS
PROPOSED VERIZON WIRELESS
GONG PAD (8'-O'X1O'-07
W NOT SCALE DAWNC$. CONTRACTOR ✓JU51 YERITI' ALL
m WWRS AM AOV15[ OiVf LTA n OF — ERRIM aA
ou6S10%e. no VA "PIONS OR LODT/GSTIOR% TO WORK
APPAOVNN.. A PRD1IX4 ISSUES OF TMG DRAXINCt AK
Sffl SfOEO BY TW LATESr WMS104. ALL DRA1 CA A+m
SIEMHF 1�ATMICORROIAPON. 1T1't4ft Moffi Ss N IZ�RSHA"
NOR THE A HIITIMT YAu. 6i PRWDING COHSTRIIGTWN
RENEW OF IRIS PROJECT.
I CONSTRUCTION I
1 1 05/22/19 ISSUED FOR PERMIT
B 04/24/19 5G ADDITION
0 10/19/17 ISSUED FOR PERMIT
A 08/16/17 ISSUED FOR REVIEW
No. Date Revision
verizonv
nentotion Team:
CROWN
CASTLE
1505 WESTLAKE AVE N, SUITE 800
SEATTLE, WA 98109
M.9
n
MORRISON HERSHFIELD
600 STEWART ST, SUITE 200
SEATTLE, WA 98101
Tel: 206.268,7370
—,monies he hfield.com
BU# 846423
FEDERAL WAY
1628 SOUTH 344TH STREET
FEDERAL WAY, WA 98DO3
Title:
ELEVATIONS
Project Number
'Start Date:
1800386
08/11/17
Drafter:
Designer.
RR
LB
Project Manager.
(Professional of Recortl:
IRKL
IRL
Reriaian No:
Sheet No:
wwj
24'x36' SCALE 1/8' = V-0'
11'x17' SCALE. 1/16' = 1'-0' X V 4 2 D
EXISTING ELEVATION ` 2 11-xl7= Ste` 1/16' ='1' 0'
PROPOSED ELEVATION 11
CCCROWN
CASTLE
June 11, 2019
CITY OF FEDERAL WAY
DEPARTMENT OF COMMUNITY DEVELOPMENT
33325 8th Avenue South
Federal Way, WA 98003-6325
1505 Westlake Ave N
Seattle, WA 98109
RE: Eligible Facilities Request to modify equipment on a communications tower located at:
1622 SOUTH 344TH STREET, FEDERAL WAY, WA, 98003 (aka 1628 S 34411' ST)
Crown Site Number: 846423 / Crown Site Name: FEDERAL WAY
Customer Site Number: CR_SKATING_CENTER / Application Number: 476495
Phone:(206) 336-2863
Fax:
www.crowncastle.com
Crown Castle USA Inc. ("Crown Castle") on behalf of Seattle SMSA Limited Partnership ("Verizon Wireless") is
submitting the attached Eligible Facilities Request application to add transmission equipment on a telecommunications
tower located at 1622 SOUTH 344TH STREET, FEDERAL WAY, WA 98003 in CITY OF FEDERAL WAY, WA (the
"FEDERAL WAY Tower").
Section 6409 of the Middle Class Tax Relief and Job Creation Act of 2012, commonly known as the "Spectrum Act"
(Pub. Law No. 112-96,126 Stat 156), mandates that state and local governments "may not deny, and shall approve, any
eligible facilities request for a modification of an existing wireless tower or base station that does not substantially
change the physical dimensions of such tower or base station." Additionally, if "the reviewing State or local government
determines that the application is incomplete" [they] "must provide written notice to the applicant within 3o days of
receipt of the application, clearly and specifically delineating all missing documents or information." Under federal law,
an Eligible Facilities Request is deemed granted with written notification in sixty (60) days after an application is filed
with a local jurisdiction, excluding tolling. Based on the submittal date of June 11, 2019, 3o days will expire on July 11,
2019; 6o days will expire on August 10, 2019.
Verizon Wireless proposes to modify the "FEDERAL WAY Tower" as follows:
New colocation of
(9) Antennas
(1) MW Antenna
(9) RRU
(2) Junction boxes
New mounts
Ancillary equipment and lines
(3) Equipment Cabinet on concrete pad
(1) H-frame
(1) Ice Bridge
The Foundation for a Wireless World.
CrownCastlexom
CROWN 1505 Westlake Ave N Phone: (206) 336-2663
Seattle, WA 98109 Fax:
C C%MO CASTLE www.crowncastle.com
Itemized list of submittal documents:
EFR Application
(3) Copies of Site Plan and Elevations
Check 29772 for $141.00
Verizon Wireless is committed to working cooperatively with all jurisdictions around the country to secure expeditious
approval of requests to modify existing personal wireless service facilities. If you should require more information
regarding the Spectrum Act, please do not hesitate to contact me with your questions.
Sincerely,
,At qxkv��
Amelia Medder
Amelia.Meckler@crowncastle.com
(2o6) 336-2863
The Foundation for a Wireless World.
CrownCastlexom