22-102451City of Federal Way
Community Development Dept.
33325 8th Ave S
Federal Way, WA 98003
Ph: (253) 835-2607 Fax: (253) 835-2609
Building - Single Family
Permit #:22-102451-00-SF
Inspection Request Line: (253) 835-3050
Project Name: THE WOODLANDS AT REDONDO CREEK LOT 1
Project Address: 1928 S 302ND ST 4
Parcel Number: 95265100 1
Project Description: BLUEBEAM - Construction of a 2770 sgipare J
2-story single family residence with a 77
square foot covered entry and a 407 square foot attached garage. Includes plumbing and
mechanical.
Owner
Applicant
Contractor
Lender
EDGEWOOD TERRACE LLC
TYLER MOMDR HORTON
D R HORTON
OWNER IS LENDER
108 W STEWART
11241 SLATER AVE NE SUITE 200
11241 SLATER AVE NE SUITE 120
PUYALLUP WA 98371
KIRKLAND WA 98033
KIRKLAND WA 98033
Census Category: 101 - New Single Family House
Includes:
#1
#2
#3
#4
Occu anc Class:
R-3
Construction Type:
Type V - B
Occupancy Load:
Floor Area (sq. ft.) 1
2,770.00
Additional Permit Information
New / Additional Sq. Feet -1st Floor .....................
1170
New / Additional Sq. Feet - 3rd Floor .....................
0
New / Additional Sq. Feet - Basement ....................
0
Occupancy #1 - Construction Type .........................
Type V - B
New / Additional Sq. Feet - Garage ........................
407
Plumbing Work Valuation? .....................................
25000
Number of Stories ...................................................
0
Plumbing to be Included? ........................................
Yes
Will Certificate of Occupancy be Issued? ...............
Yes
Comprehensive Plan Designation ........................... SF - High -Density
Residential
Total Valuation: 363,948.78
New / Additional Sq. Feet - 2nd Floor ....................
1600
Occupancy #1- Area (Sq. Feet) ..............................
2770
BasicPlan?...........................................................
No
New / Additional Sq. Feet - Deck ...........................
0
Mechanical to be Included? .....................................
Yes
Mechanical Work Valuation? ..................................
20000
New / Additional Sq. Feet - Other ..........................1
77
New / Additional Sq. Feet - Total ...........................
3254
Occupancy #1 - Use ................................................
Residence (1 or 2
family)
Zoning Designation...............
RS 5.0
Mechanical Fixtures
Fans 6 Furnaces
Plumbing Fixtures
Bathtubs 2 Dishwashers
Lavatories 4 Showers
Water Closets 3 Water Heaters
CONDITIONS:
no CO until the sales office is removed and turn back to garage.
1 Gas Piping 2
1
1 Laundry Washer Outlets 1
2 Sinks 1
1 Hose Bibbs 2
PERMIT EXPIRES Wednesday, 25 January, 2023
Permit Issued on Friday, July 29, 2022
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
Washington and the City of Federal Way.
Owner or agent: I I 1z Date:
City of Federal Way
Certificate of occupancy
This Certificate issued pursuant to the requirements of Section III of the International Building Code or Section
R110 of the International Residential Code is certifying that at the time of issuance, this structure was in
compliance with the various ordinances of the City regulating building construction or use. This certificate is valid
ONLY when endorsed by City staff.
Tenant Name: THE WOODLANDS AT REDONDO CREEK LOT Permit # 22-102451-00-SF
Address: 1928 S 302ND ST
Includes: #1 #2 #3 44
Occupancy Class: R-3
Construction Type: Type V - B
Occupancy Load:
Floor Area (sq. ft.) 2,770.00
Owner Name: EDGEWOOD TERRACE LLC
Owner Address: 108 W STEWART
PUYALLUP WA 98371
B ilding Official Date
Tl ie priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
experience has shown most severely affect the health and safety of the general public. Although the City has made as complete
a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees
nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every
ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon
which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises.
' 1 1
CITY OF
Federal Way
THIS CARD IS TO REMAIN ON -SITE
Construction Inspection Record
INSPECTION REQUESTS: (253) 835-3050
PERMIT #: 22 102451 00 Address: 1928 S 302ND ST
Project: D R HORTON FEDERAL WAY WA 98003
Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card.
El
SWM Precon Site Mtg (4400)
0
Site Assessment (Erosion) (4365)
❑
Footings/Setback (4110)
Approved
To be done PRIOR to breaking ground
Approved to place concrete
By
Date
By
Date
By
Date ( Lzl
0 Foundation Wall (4115)
0 Drainage/Downspout (4040)
® Plumbing Groundwork (4190)
Approved to place concrete
Approved to backfill
Approved to cover
By Date9 L 1?z
T
By Date— 077 /2/1/
By Date
Q Slab/Concrete Floor (4255)
❑ Underfloor Framing (4285)
® Floor Sheathing (4105)
Approved to place concrete
Approved to sheath floor
Approved to install flooring
By Date
By U Date
By , Date 1 v h( zz__�
to Shear Walls (4245)
11 Roof Sheathing (4220)
Rough Plumbing (4230)
Approved to install siding
Approved to install roofing
Approved
By o Date I a ��
By Date a 11 ��
By U Date 10
Mechanical Rough -in (4165)
14 Gas Piping (4125)
t s Fire/Draft Stops (4095)
Approved
Approved to release test
Approved
By ,� Date Q
Lgki
By ® Date)0 ? 9- '��
By �� Date U
1 fi Interim Erosion Control (4370) Prior to scheduling a Framing inspection;
Approved Electrical, Plumbing & Mechanical Rough -in
and Fire/Draft Stop inspections must be signed -
By Date off and approved. IBC 109.3.4
9� Framing (4120)
Approved to insulate
By O Date J o k i /a"
1$ Insulation (4150)
i9 Gypsum Wallboard Nailing (4130)
24 Final Erosion Control (4375)
Approved to install wallboard
Approved to install mud & tapc
Approved
By Date �kh
By Date
By Date
21 Final - Mechanical (4065)
Approved
Final - Plumbing (4075) IF,
By Date -1 L1�3 By 6 Date
n �we
*r AP��c�U
�3 II By
Final - Building (4050)
Approved
Date
'�o wiwirJ
❑
Rough Electrical
El
Final Electrical
Right of Way
Approved
Approved
Approved
By
Date
By
Date
By
Date
`FOF
ederal Way
Buildin� Divisiop
33325 Eighth Avenue South
Federal Way, WA 98003-6325
Phone 253-835-2607 Fax 253-835-2609
CORRECTION NOTICE
ADDRESS: �� fi PERMIT#:_ `2 — [o2 q 5
! . P + � _ �o�.s � b �- ��c►�•e� � r t.�.r .�-��� � �, ���.. -fir
,66
3 •—Dena 1 1 l � 1 - _ � � " �oo :�►a I�sL�� �' $"� �t L)
5
IF YOU HAVE QUESTIONS CALL (253) 835-
WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-30 0 FOR RE -INSPECTION. SEE BACK OF CARD
FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS.
r,..TE INSPECTOR
DO NOT REMOVE THIS NOTICE
Page of
CITY OF Building Division
33325 Eighth Avenue South
Federal Wa , Federal Way, 98-6325
y Phone 253-835-2607 Faxx 253-835835-2609
CORRECTION NOTICE
ADDRESS: - l� 5 �d� S� PERMIT#: 2���-�0f ^06
IF YOU HAVE QUESTIONS CALL ,fie Wq (253) 835- M?
J
WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD
FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS.
DATE INSPECTOR
DO NOT REMOVE THIS iiOTICE
Page of
LW
1
l'
r�l
all
1 .
n . F
i
n
t y t1
y. .
VOELKER ENGINEERING INC.
i93 N Shugart Flats Rd.
Leavenworth, Washington 98826
425-417-1122
chades®voelkereng.com
NAIL OSB TO STUDS. —
SPACE NAILS PER EDGE
NAILING ON SHEARWALL
SCHEDULE
IN
SHM NO.
WOODLANDS AT REDONDO LOT 1
OF
CALaAAI D BY CV DALE 10 13 22
USE SIMPSON "SET—XP or SET-3G"
EPDXY OR APPROVED EQUAL.. IF CONCRETE
TEMPERATURE IS BELOW 50' USE
SIMPSON "AT—XP" ACRYLIC TIE OR
APPROVED EQUAL. OBTAIN SPECIAL
INSPECTION.
DRILL )41"x 12" DEEP HOLE. BLOW OUT
DEBRIS, CLEAN OUT WITH BRUSH AND
BLOW OUT DEBRIS A SECOND TIME.
FILL HOLE % FULL W/ EPDXY STARTING
FROM THE BOTTOM TO PREVENT AIR
POCKETS. INSTALL 5" ALL —THREAD ROD.
Iff�llll�!
EXISTING FOUNDATION L
2W
PROVIDE 2 STUDS
NAIL TOG ER W/ 16d ® 6" o.c.
SIMPSON HDU5 W/
(14) SDSXUZ2 SCREWS
INTO DOUBLE STUDS
IIl�---1111�
HDU5 HOLDOWN RETROFIT 1 o 1 t 312 2
TO REPLACE STHD14
EXPIRES 9121,/ Z3
CITY OF Building Division
33325 Eighth Avenue South
Federal Way Federal Way, Fax
98003-vzl�hL6325
Phone 253-835-2607 Fax 253-35-609
CORRECTION NOTICE
ADDRESS: 5 �5Zh8 S+' PERMIT#: n_ I O 6 ! "00
04
- secti•iP � Zoo ► ,1 - -
IF YOU HAVE QUESTIONS CALL l (253) 835
WHEN CORRECTIONS HAVE BEEN MADE, CALL (2 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD
FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS.
yea. 0 'Nx
DATE INSPECTOR
DO NOT REMOVE THIS OT1OE
Page of