Loading...
22-101378City of Federal Way Community Development Dept. 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Building - Multi Family Permit #:22-101378-00-MF Inspection Request Line: (253) 835-3050 Project Name: MOUNTAIN SUN APARTMENTS Project Address: 1747 S 305TH PL Parcel Number: 255817 0050 Project Description: BLUEBEAM - Repair fire -damaged 7-unit apartment building. Owner Applicant Contractor Lender YURIY MOMOTYUK YURIY MOMOTYUK YUMO CONSTRUCTION LLC OWNER IS LENDER 27327 48TH AVE S 27327 48TH AVE S 27327 48TH AVE S KENT WA 98032 KENT WA 98032 KENT WA 98032 Census Category: 434 - Residential alt/add - no change in number of units Includes: #1 #2 #3 #4 Occupancy Class; R-2 Construction Type: Type V - B Occupancy Load: Floor Area-(sq. ft.) 0.00 Additional Permit Information Occupancy #1 - Construction Type ......................... Type V - B Mechanical to be Included? ..................................... Yes Plumbing Work Valuation? ..................................... 30000 Mechanical Work Valuation?.................................. 25000 Number of Stories...... ................. ».. :.....».... I Is this an Online or O.T.C. application?.................. No Permit for Building Shell Only? .............................. No Plumbing to be Included?........................................ Yes Will Certificate of Occupancy be Issued? ............... No Occupancy #1 - Use................................................ Apartment House Comprehensive Plan Designation ........................... Multifamily Zoning Designation ................................................. RM 1800 Total Valuation: 300,000.00 Mechanical Fixt Air Conditioners - Stand Alon( 7 Fans 15 Plumbing Fixtures Bathtubs 8 Dishwashers 7 Sinks 7 Water Closets 8 Water Heaters 8 Hose Bibbs 2 CONDITIONS: Fire conditions: A NFPA 13R fire sprinkler is required per the IEBC. A separate permit is required to install the fire sprinkler system. PERMIT EXPIRES Saturday, 10 December, 2022 Permit Issued on Monday, June 13, 2022 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of L. the City of Federal Way. Owner or agent: iDate: City of Federal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: MOUNTAIN SUN APARTMENTS Address: 1747 S 305TH PL Permit # 22-101378-00-NM Includes: #1 #2 #3 #4 Occupancy Class: R-2 Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) 0.00 Owner Name: YURIY MOMOTYUK Owner Address: 27327 48TH AVE S KENT WA 98032 Building Officialf )l6L 23 Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises. CITY OF Federal Way THIS CARD IS TO REMAIN ON -SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 22 101378 00 Address: 1747 S 305TH PL Project: YUR EY MOMOTYUK FEDERAL WAY WA 98003-4893 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE TITIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. 0 Site Assessment (Erosion) (4365) Footings/Setback (4110) 0 Foundation Wall (4115) To be done PRIOR to breaking ground Approved to place concrete Approved to place concrete By Date By Date By Date ® Drainage/Downspout (4040) Ll Re -steel (4215) ® Plumbing Groundwork (4190) Approved to backfill Approved to place concrete or grout Approved to cover By Date By Date By Date 0 Slab/Concrete Floor (4255) ® Underfloor Framing (4285) ® Floor Sheathing (4105) Approved to place concrete Approved to sheath floor Approved to install flooring By Date By Date By Date F® Shear Walls (4245) El Roof Sheathing (4220) 1z Rough Plumbing (4230) Approved to install siding Approved to install roofing Approved By Date By Date 421 17 By 4,3 Date !&L i3 Mechanical Rough -in (4165) 14 Gas Piping (4125) t Fire/Draft Stops (4095) Approved Approved to release test Approved By Date q1w' By Date By Date l� Interim Erosion Control (4370) Prior to scheduling a Framing inspection; 17 Framing (4120) i Electrical, Plumbing & Mechanical Rough -in Approved Approved to insulate and Fire/Draft Stop inspections must be signed - By Date off and approved. IBC 109.3.4 By Date 8 Insulation (4150) 1s Gypsum Wallboard Nailing (4130) z€1 Suspended Ceiling Grid (4265) Approved to install wallboard Approved to install mud & tape Approved to drop tile By Date By Date By Date El Final - S K F & R (4060) 2z Final - Planning 2s Final - Public Works (4080) Approved Approved Approved By Date By Date By Date 24 Final Erosion Control (4375) �6 Final - Mechanical (4065) 25 Final - Plumbing (4075) Approved Approved Approved By Date By Date By Date 0 Final - Building (4050) Approved � fl) By Date 1 El Rough Electrical Approved By Date Final Electrical Right of Way Approved Approved By Date By Date .. r P S TAT E Ri'�IdUengineering, in 224W SUITE 2C, MOUNTLAKE TERRACE, WA 98043 T8.COM TEL: (425) 354-4105 FAX: NOPE September 9, 2022 Yumo Construction LLC Attn: Yuriy 27327 48th Ave S Kent, WA 98032 Re: Upstate Job#1343 New Duplex Inspector Response Permit# BLDRN21-0119 To Whom It May Concern: The deck joist were constructed as follows: PT 2x10 @ 16" with 4' cantilevered, 8' backspan The attached calculations show the selected joists are structurally adequate. The backspan should be fastened (sistered) to floor joists using (2) rows of 16d @ 12" OC. Should there be any questions or comments please contact our office. Sincerely, Andrew Gahan, PE 9/9/ZOZZ UPSTATE Lglen inc. }MW►41H MS W. 61A1E X. MOUNTL E TERRACE. WA 98043 �LCGV rM (425) 35 4105 FAX: JUST OON'T Wood Beam Project Title: 1747 S 305th PLACE Engineer: airing Project ID: 1602 Project Descr: APARTMENTS LIC# : KW-06013781, Build:2022.8.17 Upstate Engineering, Inc. DESCRIPTION: DECK JOISTS CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: IBC 2018 Material Properties Analysis Method : Allowable Stress Design Fb + 850 psi Load Combination : IBC 2018 Fb • 850 psi Fc - Prll 1300 psi Wood Species Hem -Fir Fc - Perp 405 psi Wood Grade No.2 Fv 150 psi Ft 525 psi Beam Bracing Beam is Fully Braced against lateral -torsional buckling Fd 2x10 Span = 8.0 ft Project File: 1602 GRAVITY.ec6 (c) ENERCALLC INC 1983-2022 E : Modulus of Elasticity Ebend- xx 1300 ksi Eminbend - xx 470 ksi Density 26.84pcf t1(O.01333) L{0.079981 A 2x10 Span = 4.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 2 Uniform Load : D = 0.010, L = 0.060 ksf, Tributary Width = 1.333 ft, (DECK) DESIGN SUMMARY Maximum Bending Stress Ratio = 0.44a 1 Maximum Shear Stress Ratio Section used for this span 2x10 Section used for this span fb: Actual = 418.77psi fv: Actual Fb: Allowable = 935.00 psi Fv: Allowable Load Combination +D+L Load Combination Location of maximum on span = 8.000ft Location of maximum on span Span # where maximum occurs = Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.126 in Ratio = 762>=240 Span: 2: L Only Max Upward Transient Deflection -0.036 in Ratio = 2700>=240 Span: 1 : L Only Max Downward Total Deflection 0.147 in Ratio = 652 >=180 Span: 2: +D+L Max Upward Total Deflection -0.041 in Ratio = 2314>=180 Span: 1 : +D+L Maximum Forces & Stresses for Load Combinations Load Combination maxstress Ratios Segment Length Span # M V Cd CFiV C i Cr Cm C t CL D Only Length = 8.0 ft 1 0.071 0.035 0.90 1.100 1.00 1.00 1.00 1.00 1.00 Length = 4.0 ft 2 0.071 0.035 0.90 1.100 1.00 1.00 1.00 1.00 1.00 +D+L 1.100 1.00 1.00 1.00 1.00 1.00 Length = 8.0 ft 1 0.448 0.218 1.00 1.100 1.00 1.00 1.00 1.00 1.00 Length = 4.0 ft 2 0.448 0.218 1.00 1.100 1.00 1.00 1.00 1.00 1.00 +D+0.750L 1.100 1.00 1.00 1.00 1.00 1.00 Length = 8.0 ft 1 0.282 0.137 1.25 1.100 1.00 1.00 1.00 1.00 1.00 Length = 4.0 ft 2 0.282 0.137 1.25 1.100 1.00 1.00 1.00 1.00 1.00 +0.60D 1.100 1.00 1.00 1.00 1.00 1.00 Length = 8.0 ft 1 0.024 0.012 1.60 1.100 1.00 1.00 1.00 1.00 1.00 Length = 4.0 ft 2 0.024 0.012 1.60 1.100 1.00 1.00 1.00 1.00 1.00 0.218 : 1 2x10 = 32.69 psi 150.00 psi +D+L 8.000 ft Span # 1 Moment -Values ear Values M fb Fb V fv F'v 0.00 0.00 0.00 0.00 0.11 59.82 841.50 0.04 4.67 135.00 0.11 59.82 841.50 0.04 4.67 135.00 0.00 0.00 0.00 0.00 0.75 418.77 935.00 0.30 32.69 150.00 0.75 418.77 935.00 0.30 32.69 150.00 0.00 0.00 0.00 0.00 0.59 329.03 1168.75 0.24 25.68 187.50 0.59 329.03 1168.75 0.24 25.68 187.50 0.00 0.00 0.00 0.00 0.06 35.89 1496.00 0.03 2.80 240.00 0.06 35.89 1496.00 0.03 2.80 240.00 UPSTATE engineering, inc. G OM WTH AVE W -SUITE 2C. MOUI4TLANE TERRACE. WA Y SERVICES®UPSTSCOM TEL:(425)3544105 FA%:JUSTOONT Project Title: 1747 S 305th PLACE Engineer: amg Project ID: 1602 Project Descr: APARTMENTS Wood Beam LICa: KW-MO-1 781, - lld:20,22.8.17 -- T Upstale Engineering. Inc. DESCRIPTION: DECK JOISTS Overall Maximum Deflections Load Combination Span Max. "-" Deft Location in Span Load Combination 1 0.0000 0.000 +D+L +D+L 2 0.1470 4.000 Vertical Reactions Support notation : Far left is #1 Load Combination Support 1 Support 2 Support 3 vera imum -0.0 3 0.467 Overall MINimum -0.013 0.400 D Only -0.013 0.067 +D+L -0.093 0.467 +D+0.750L -0.073 0.367 +0.60D -0.008 0.040 L Only -0.080 0.400 Project File: 1602 GRAvITY.ec6 (c) ENERCALC INC 19 3.2022� Max. "+" Defl Location in Span -0.0415 4.648 0.0000 4.648 Values in KIPS CITY OF 41;�A�L Federal Way ADDRESS: 1 -� c + Builtding Divislbn 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ra PERMIT#:_ .2� /01 S7 9 _ _�� IF YOU HAVE QUESTIONS CALL (253) 835- z63 9 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. 1�2 9 tip) D E INSPECTOR DO NOT REMOVE THIS NOTICE Page of CITY OF Building Division 33325 Eighth Avenue South FederalWay Federal Way, x 98835-2609 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: 2 4 PERMIT#:_ice- IF YOU HAVE QUESTIONS CALL (253) 835- Z'4 loll WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. 12e7 L2_ DAT DO NOT REMOVE TH INSPECX,OR NOTICE Page of `FOF ederal Way Building Division 33325 Eighth Avenue South Federal Way, WA 98003a6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: 1. J ka:ndra' 1 � � rp.%. PERMIT#: 4;0 -/U 13 79" WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. 115 1z DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of