Loading...
21-103805-Plan Set-09-14-2021-V1RECEIVED v6 z O Ln w ry PROJECT DATA DECK REPLACEMENT/MODIFICATION FOR LAKE FASTER ESTATES 1301 S. 308thl Federal Way, WA 98003 DRAWING INDEX PROJECT: DECK REPLACEMENT/MODIFICATION A-0 AREA: 2 & 3 BEDROOM UNITS A-1 ACCESSOR PARCEL NO: 401540 0000 SITE ADDRESS: 1301 S. 308th - LAKE EASTER ESTATES S-1 JURISDICTION: CITY OF FEDERAL WAY S-2 ZONING: RM1800 OCCUPANCY GROUP: TYPE OF CONSTRUCTION: V-B APPLICABLE CODES: IBC 2018, NDS 2018, AISC 7-10 LEGAL DESCRIPTION COVER SHEET, PROJECT STATS, SITE PLAN FLOOR PLAN, ELEVATIONS, BUILDING SECTIONS DETAILS NOTES THE NORTHWEST QUARTER OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 8, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M., KING COUNTY, WASHINGTON, EXCEPT THE EAST 165 FEET, AND EXCEPT THE NORTH 30 FEET THEREOF, CONVEYED TO KING COUNTY FOR ROAD BY DEEDS RECORDED UNDER AUDITOR'S FILE NUMBERS 2392432 AND 2600370. EXCEPT THE SOUTH 3.0 FEET OF THE WEST 10.00 FEET OF THE EAST 148.38 FEET OF THE ABOVE DESCRIBED PARCEL SUBJECT TO AND TOGETHER WITH EASEMENTS OF RECORD, ALSO SUBJECT TO ANY RESTRICTIONS AND RESERVATIONS OF RECORD. APPLICABLE CODES * WASINGTON STATE BUILDINGS CODES AND AMENDMENTS * WASHINGTON ADMINISTRATIVE CODE (WAC) * FEDERAL WAY MUNICIPAL CODE VICINITY MAP SITE LOCATION Life Care Center of Federal Way ter of 141+ay � 30801 13th Ave S #28, Federal Way, WA 98003 Lake Easter * 2018 INTERNATIONAL BUILDING CODE W/ WASHINGTON STATE AMENDMENTS * 2018 INTERNATIONAL EXISTING BUILDING CODE * 2018 INTERNATIONAL FIRE CODE W/ WASHINGTON STATE AMENDMENTS * 2018 WASHINGTON STATE ENERGY CODE F Sep 20 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT -_ 308 thSt.0. BLDG 11 BLDG 10 BLDG 9 -_ -- M BLDG 8 r 0 0 N N N N] � wN- r � ■ O30B41 01 30803 o BLDG 7 cN 30B0530807 r- 2h a M; TOM 30809 3o61BLDG 6 30813 30815 1 1 LEGAL DESCRIPTION THE NORTHWEST QUARTER OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 8, TOWSHIP 21 NORTH, RANGE 4 EAST, W.M., KING COUNTY, WASHINGTON, EXCEPTTHE EAST 165 FEET, AND EXCEPT THE NORTH 30 FEET THEREOF, CONVEYED TO KING COUNT FOR ROAD BY DEEDS RECORDED UNDER AUDITOR'S FILE NUMBERS 2392432 AND 2600370. EXCEPT THE SOUTH 3.0 FEET OF THE WEST 10.00 FEET OF THE EAST 148.38 FEET OF THE ABOVE DESCRIBED PARCEL. SUBJECT TO AND TOGETHER WITH EASEMENTS OF RECORD, ALSO SUBJECT TO ANY RESTRCTIONS AND RESERVATIONS OF RECORD. i� Lake Easter Estates E.0&6 30817 P 9 2 30819 BLDG 5 1 30821 30823 1 6 30825 ,� 30827 BLDG 4 4 30829 13 30831 12 30833 11 30835 BLDG 3 1 d 30837 n 30939 S 30841 Xy 7 30943 BLDG 2 6 30845 5 r,- 30847 30849 ' 30851 BLDG 1 30853 30855 n 0 z rU) 0 (n (n = J r 3Of L0 Frwz U (/, 0- J O it az'z } } J Z > Q QN�mli p OQ� ZwIFUIiwO F0 Q>z C'�OUd'Z �a�oQ Zw Ow(wn OU F O m 7 0 N Qw wJ!�,r >0E-m r w z _a_Fo d Q J O ONQ WZ(n ZU aZ(r wP`'_O¢U 03zN U,w�_}O _ O m Z QF —O}>Q z QWF- m3 aJ �r6Q)- O w Z Q 0 m m F u)Z)oF- o � 00 E M O O m LLJ� Z U ry c� Z Q U' N _ 3 UzN3 J O Cn W V / C/� W ILd � C) Q 0:� 00 0 z'—,`n w Lc)/� N ) :5 z= O —D U N O N 04 ILYL I� U) w 0 0 Q m O D L r LL LL V k, W Q U) w Q w� U) C) w LLI Dry U w DRAWN: U) w 0 0 Q m O D L r LL LL V k, W Q U) w Q w� U) C) w LLI Dry U w DRAWN: WMD JOB NO: 2011011X DATE: 9/1 /2021 SHEET: A-001 TECHNICAL BULLETIN Detail A DTT2 to joist layout �, r `w Rijn joist 1FVI F I � I Il Detail B t4 .' Deck joists— D72 to Blocking blacking _ layout. ` r Band: joist , • DTT2 Attachment of Guardrail Post Outside Rim/Joist Post Post DTT2 (} DTT2 Decking Decking (one each side) (typ.) (typ.) r p 0) f]n 0 0 p O ran q 0 0 q L r� AV 112" diameter Rim +/2' diameter I 16, mien , machine bolts or joist Joist machine bolts Blocking threaded rods with or threaded rods nuts and washers with nuts and Joist washers Plan View Detail A Elevation Detail B GENERAL NOTES —IBC 2018 DAMAGED AREAS IN WALLS SURROUNDING THE DECK SHALL BE REPLACED W/ EQUAL MATERIAL. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. CODES AND SPECIFICATIONS INTERNATIONAL BUILDING CODE-2018 EDITION 2. ACI 318-05 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE 3. WESTERN PRODUCTS USE BOOK 4. SIMPSON STRONG TIE CONNECTORS CATALOG— 2015. TIMBER CONSTRUCTION 1. LUMBER GRADES AND ALLOWABLE STRESSES SHALL BE DF—#2 MIN. UNLESS NOTED OTHERWISE ON PLAN: ALL WOOD EXPOSED TO WEATHER, SUCH AS WOOD USED FOR DECK FRAMING, INCLUDING DECKING, RAILINGS, JOISTS, BEAMS AND POSTS SHALL BE PRESSURE TREATED OR WOOD WITH NATURAL RESISTANCE TO DECAY. FRAMING NOTES FRAME NAILING TO BE IN COMPLIANCE WITH IBC TABLE 2304.10.1 PROVIDE HOT —DIPPED GALVANIZED (ELECTRO—PLATING IS NOT ACCEPTABLE) NAILS IN CONTACT WITH PRESSURE TREATED FRAMING MEMBERS. IBC 2304.10.5. THE USE OF SIMPSON SD SCREWS IS PREFERRED OVER NAILS. USE: SD10112 (#10 X 1 1/2") INSTEAD OF 16d NAILS. SD9112 (#9 X 1 1/2") INSTEAD OF 10d NAILS. WHERE LONG SCREWS ARE REQUIRED, USE 2 1/2" LONG SCREWS. (SEE ALSO PG 27, C-2015 SIMPSON WOOD CONST. CONNECTORS CAT.) ALL CONNECTORS TO BE HOT —DIPPED GALV (HDG), ZMAX, OR STAINLESS STEEL (S.S.). CONNECTORS AND THEIR FASTENERS ARE TO BE LIKE MATERIAL (I.E. HDG FASTENERS W/ HDG OR ZMAX CONNECTORS; S.S. FASTENERS W/ S.S. CONNECTORS). SIDS SCREWS ARE TO HAVE DOUBLE BARRIER COATING. ATTACH LEDGER DIRECTLY TO RIM JOIST. 1 /8" 0 SCREW (GUARD DOG BRAND BY FASTEN MASTER) BALLUSTERS TO GUARDRAIL PENETRATION SECTION SCALE 2" = 1'-0" 2-1/8" 0 SCREWS GUARD DOG BRAND BY FASTEN MASTER) HANDRAIL TO POST W/ 1 1/2" MIN. PENETRATION 2-1/8" 0 SCREWS GUARD DOG BRAND BY FASTEN MASTER) GUARDRAIL TO POST W/ 1 1/2" MIN. PENETRATION 2X2 BALLUSTER (typ) RAILING POST BEYOND ;e1m:T1I:1� ACTUAL CONDITIONS THIS SECTION SEE SIMPSON STRONG TIE DETAILS SHEET 2 FOR CODE COMPLIANCE OF POST ATTACHMENT SECTION 1 JOIST JOIST Rill 131 SCALE 1" = 1'-0" Simpson LUS210 Hanger vc Blocking locking Blocking 2L: Simpson LUS210 Hanger im son Hanqer SECTION ELEVATION GUARDRAIL/ BALLUSTER DETAIL 4X4 POST ?) 2X JOISTS (e) 1 X FASCIA (e) UPPER FLOOR INTERIOR -T-111 (e) PLYWOOD (e) (e) (EXISTING 3TU S AS SECTION 2 (2) 2X JOISTS ,�-4X4 POST (2) " diameter -"machine bolt with nut and washers Alternate Guardrail Post 1 X FASCIA So 4" sphere can not pass through ;AILING POST typ) 4" MAX. OPENI /GBETWEEN 3ALLUSTERS 4" MAX. OPENING BETWEEN GUARDRAIL AND DECKING SECTION A TYPICAL SIDE ELEVATION CONTRACTOR TO VERIFY EXISTING FRAMING CONSTRUCTION. IF DIFFERENT FROM THE ASSUMED COMPONENT FRAMING, PLEASE CONSULT DESIGNERS/ ENGINEERS BEFORE PROCEEDING. TYPICAL EXISTING UPPER BALCONY FRAMING PLAN FRAMING (e) 2X FLOOR JOISTS (e) 2X P.T. PLATE FOUNDATION (e) ►�i�11►�[eh/_1�1 0 EXTENT OF REPLACEMENT 2 WING WALL RECEIVED Sep 20 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT 2X6 @ 16" O.C. TYPICAL FRAMING ELEVATION AT WING WALL TYPICAL FRONT ELEVATION EXTERIOR WALL BELOW RAILING POST (typ) DF#2 @ APPROX. 48 C. S SHOWN a OUTLINE OF DECK BELOW L — TYPICAL UPPER BALCONY FLOOR PLAN SCALE : 1 /4" = 1'-0" i9li[el�i%[� EXTENT OF REPLACEMENT DETERIORATED WING WALL TO BE REPLACED PER OWNER'S INSTRUCTIONS PRE —PERMIT DRAWINGS THESE DRAWINGS ARE SUBJECT TO REVISIONS PENDING LOCAL JURISDICTIONAL REVIEW AND ARE NOT FINAL UNTIL APPROVED Q a a J J J N 0_ O a_0000 N U U U > N U) 00 W Of O O O N N N N N N O] m m N M z O � N Q N N O 0 o 0 M O n O LL 0) LL_I Z O � S J (V Z i= < 0 Q oa Fc~.>= 3 W 0F0Z U z N z 0(na� 3 J J O- ZozK v�}) 0-FWON Q ��oUF�oLW ) ~oo L,W Oo 00 iQmz�oroa \JW wow 000n z��aW Ln o= Was LO >o�r z Nao -'z WDw D U WW JUOQU) O OU)Q N D Zz-) 0 a- WPNZo0r Q O Q,ZN (� OWW Ld F = Q r O m Z OF- �=zo0< Z�arrF s 0- �r ¢� ow—z ¢ m o�� �UO~O CN co a 0 w o W Q W � O CD 00 W O-) Q W /n < v J Q:: U) o Q CD LLJ I� o Q I I1� W DRAWN: WMD JOB No: 2011011 X DATE: 09 /01 /21