Loading...
20-104064-CO-Site PlanA C IN E F G H J 1:1 1N F 3 4 5 0 7 0 10 12 13 14 15 16 - TENANT IMPROVEMENT - 1610 S. 341st Place, Suite B Federal Way,WA 98003 PROJECT GENERAL NOTES PROJECT DATA VICINITY MAP PROJECT DIRECTORY DRAWING INDEX 1. SEE APPROPRIATE DRAWINGS FOR GENERAL NOTES OF OTHER CONSTRUCTION TYP : EXISTING CONSTRUCTION TYPE: 9 0 v -A,Q 0 °' ARCHITECT: smith co Ilc ARCHITECTURAL DISCIPLINES: STRUCTURAL, ELECTRICAL, MECHANICAL AND TYPE 5A NON-SPRINKLERED $,; =,3a,a° ' _.. ° ~,, . ° 603 STEWART STREET PLUMBING. 9=71 vv — SUITE 610 G-1.1 GENERAL INFORMATION 2. DO NOT SCALE DRAWINGS- USE DIMENSIONS ONLY. OCCUPANCY GROUP: PRI Y PA : A2- TAURANT ° PROJECT �G SEATTLE, WA 98101 G-1.2 CODE INFO - SIGNAGE 3. DIMENSIONS WHERE SHOWN ARE NORMALLY GIVEN: ❑ONING: a °°"°'°"""`"' LOCATION v G-1.3 CODE INFO - TOILET ACCESSIBILITY A. TO COLUMN CENTER LINE " v © M: 206.713.4076 G-1.4 CODE INFO - DOOR APPROACH B. TO FINISH FACE OF CMU OR GWB. APPLICABLE CODES: 2015 International Building Code JBCL a. T: 206.466.5239 G-1.5 CODE INFO - REACH/HEIGHTS 4. DIMENSIONS SHOWN ON LARGER SCALE DRAWINGS GOVERN. 2015 International E-isting Building Code �IEBC G-1.6 CODE SUMMARY 5. FIELD VERIFY ALL EXISTING CONDITIONS. REVIEW EXISTING 2015 International Residential Code �1RC�o 9F.- PROJECT MANAGER: Keith Smith G-1.7 EGRESS PLAN CONDITIONS PRIOR TO COMMENCING THE WORK, NOTIFY vPo° E-Mail:ksmith@smithco.org G-1.8 SITE PLAN ARCHITECT OF UNEXPECTED CONDITIONS. 2015 International Mechanical Code AMC[] " 9 o 9 vKK•,„�v rEoQ 6. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB, UNLESS NOTED OTHERWISE. 2015 International Fuel Gas Code AFGC❑ 2015 International Fire Code AFC❑ oc° �F d a , w°.�.,d. -'' so"o. 9 , "� E y.°" w„,.°`°°'� �'�„o" v OWNER: Mi Chalateca A-1.0 CONSTRUCTION PLAN A-1.1 DIMENSION FLOOR PLAN 7. "ALIGN" AS INDICATED ON THE DRAWING SHALL BE UNDERSTOOD ' drc.,. A-1.2 PLUMBING ROUGH 2015 Uniform Plumbing Code �JPC❑ o °„gym ��,„ °9 / °g""s°" ""°' -IN -DIMENSIONS TO MEAN TO ALIGN THE FINISH MATERIAL OF THE WALLS OR•,.KK"•-� 2017 National Electric Code dNECC ,y. :ora A-1.3 FLOOR FINISH PLAN COLUMNS INDICATED. e ? 9 a•..°, A-1.4 REFLECTED CEILING PLAN 8. ALL INTERIOR GYPSUM WALL BOARD IS 5/8 " TYPE X GWB ON 2009 Accessible ❑ Usable Buildings L Facilities JCC/ G-a°°°"v o.,,., .�. ``"'v q� v� ""°' "° % METAL STUDS OR FURRING CHANNELS UNLESS NOTED ANSI Al 17.1 Li_. �ur „,.. ;/'r•m".," K-1.0 E❑UIPMENT PLAN OTHERWISE, SIEES AS DIMENSIONED ON PLANS. SEE NOTE FOR 2015 International Energy Conservation Code with WA �" °'�`°'9 g` �° v 9s..�o.°•° ° v°�:."""' , us K-1.1 E❑UIPMENT SCHEDULE LOCATION OF WATER RESISTANT GWB. ST Amendments ° ° °�n.�sv c - ° „°° ""�� """° ° ' 9:°' A-2.0 9. PROVIDE WATER RESISTANT TYPE X GWB IN ALL TOILET ROOMS, 9-•m•,•�•".� .° ENLARGED TOILET PLAN/ELEVATIONS WAREWASH AND WET AREAS. '""- v o A-2.1 ENLARGED TOILET PLAN/ELEVATIONS 10. ALL FINISH CEILING HEIGHTS SHALL BE CONFIRMED UNLESS OCCUPANCY: A2-RESTAURANT NOTED OTHERWISE ON THE ROOM FINISH SCHEDULE. v ,; ° s ^° 9 Google. o A-3.0 DETAILS 11. PROVIDE FINISH WALL BEHIND ALL E UIPMENT AND CASEWORK. A-3.1 DETAILS 12. PROVIDE ALL ACCESSIBLE SIGNAGE AS RE (UIRED BY LOCAL OR A-3.2 DETAILS APPLICABLE JURISDICTION. SEPARATE SUBMITTALS 13. PROVIDE ONE TYPE 5E-2A-10BC FIRE EXTINGUISHER PER 3,000 SCALE: N.T.S. SF AND NOT MORE THAN 75 FT OF TRAVEL DISTANCE. 14. THERE SHALL BE NO BACK-TO-BACK ELECTRICAL, TELEPHONE, SIGNAGE UNDER SEPARATE SUBMITTAL. OR OTHER OUTLETS. SEPARATE OUTLETS BY 6" AT NONRATED, FIRE SPRINKLERS AND FIRE ALARM UNDER A SEPARATE PERMIT PARTITIONS. SEPARATE OUTLETS BY 24" MIN. AT FIRE RATED MECHANICAL/ELECTRICAL AND PLUMBING UNDER SEPARATE PERMIT SITE MAP PARTITIONS. 15. WHERE H VAC OR OTHER MECHANICAL ELECTRICAL AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE .. + BRACED AND FRAMED TO STRUCTURE AS REEUIRED TO SCOPE O F WORK A PROVIDE ADE❑UATE SUPPORT. ALL PENETRATIONS THROUGH ` - RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE _ AND/OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE BUILDING: 16. FIRE STOP MATERIAL. ALL CHANGES IN PROJECT SCOPE DUE TO CONTRACTOR GENERATED ALTERNATES OR EXISTING FIELD CONDITIONS THE WORK INCLUDES, BUT NOT LIMITED TO TENANT IMPROVEMENTS FORA RESTAURANT AND RELATED SERVICES, WORK INCLUDES NON-STRUCTURAL .. SHALL BE TRANSMITTED TO THE ARCHITECT FOR APPROVAL WALLS, FINISHES -�, _ � 17. PRIOR TO INSTALLATION. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIVING AND INSTALLING OF OWNER FURNISHED ITEMS ON SITE: NONE PROJECT "'` /• w��, ' s'ld.�' ''+� • >I LOCATION '�t�:- 18. LISTED, UNO. PROVIDE EXIT ILLUMINATION PER LOCAL CODES. 99 •; - LEGAL DESCRIPTION 19 COD IGURATION INDICATED ON THE IFY THE FIRE PROTECTION TP PLANS. COMPLEM TO IY WITH ALL ODATE E GOVERNING ORDINANCES AND LANDLORD CRITERIA. _ 20. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS. SPRINKLER HEADS MOUNTED IN HARD GWB CEILINGS TO BE PARCEL NUMBER: 390380-0150 21. FULLY RECESSED WITH WHITE CAPS. INSTALL ALL COMPONENTS OF FIRE RATED ASSEMBLIES PER LEGAL:tT, , '1 Q 22. RATING CRITERIA. INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH LANDLORD KIT'S CORNER BUSINESS PARK ' son Plat Block: CRITERIA AND LOCAL CODES AS RE UIRED. 23. FIRE SPRINKLER SYSTEM WORK AND FIRE ALARM SYSTEM WORK Plat Lot: 15 IS TO BE SUBMITTED UNDER SEPARATE PERMITS. 24. PROVIDE FINISH FLOOR UNDER ALL E❑UIPMENT AND R; , CASEWORK. ALE: N.T.S. FOR ADDITIONAL ABBREVIATIONS ARCHITECTURAL ABBREVIATIONS ARCHITECTURAL SYMBOLS SEE OTHER DESIGN DISCIPLINES SYMBOLS ACOUS. ACOUSTICAL ELEV. ELEVATION ADJ ADJUSTABLE, ADJACENT ELEC. ELECTRICAL A.F.F. ABOVE FINISHED FLOOR [SLAB❑ ENCL. ENCLOSURE L. LAM. L. F. LONG, LENGTH PR. PAIR LAMINATE, LAMINATED PROJ. PROJECT LINEAR FOOT, LINEAL FOOT PRV PRESSURE REDUCING VALVE T.O.S. T.O.W. T B TOP OF STEEL TOP OF WALL TOP AND BOTTOM NORTH ARROW DETAIL IDENTIFICATION PROJECT NORTH DETAIL CUT LINE - DEFINES THE ARROW �� REVISION CLOUD ITEM S.I.O MATERIALS OR N.I.C. ALUM ALUMINUM EC. E UAL LI LI UID P.T. PRESSURE TREATED TEL. TELEPHONE DETAILED ELEMENT AND DELTA GYPSUM BOARD ANOD. ANODI ED EXH. EXHAUST L.P. LOW POINT T. LUARRY TILE TEMP. TEMPERED GLASS 3 TRUE NORTH APPROX. BD. APPROXIMATE EXIST. EXISTING BOARD EXP. EXPANSION LT.WT. MAS. LIGHT WEIGHT TR. ❑UARTER MASONRY R RADIUS TYP. UTIL. TYPICAL UTILITY A8.01 SHEET WHERE INDICATOR CONCRETE ITEM S.O.I.0 B.F.F. BELOW FINISHED FLOOR SLAB EXT. EXTERIOR MAX. MAXIMUM R.C. REFRIGERATION CONTRACTOR U.B.C. UNIFORM BUILDING CODE DRAWN DOOR MARK 50'-0" A.F.F. WORK, CONTROL OR S.I.C. 1 EARTH BLDG. BUILDING F.D. FLOOR DRAIN M.B.S. METAL BUILDING SUPPLIER R.C.P. REFLECTED CEILING PLAN U.N.O. UNLESS NOTED OTHERWISE OR DATUM POINT BLK. BLOCK FDN. FOUNDATION MECH. MECHANICAL R.D. ROOF DRAIN V.C.T. VINYL COMPOSITION TILE WALL SECTION DOOR CODE - GRAVEL BLK'G. BM. BOT. BLOCKING FF FACTORY FINISH BEAM FHS FLAT HEAD SCREW BOTTOM FL. FLOOR MFG. MFR. M.H. MANUFACTURING R.L. ROOF LEADER MANUFACTURER REC'D. RECEIVED MANHOLE REFRIG. REFRIGERATION VERT. V.I.F. W/ VERTICAL VERIFY IN FIELD WITH DETAIL IDENTIFICATION 2580A REFER TO CUT LINE - DEFINES THE SCHEDULE DETAILED ELEMENT NTI PE DIREC STION CO SLOPE DOWN WITH DATUM MARK LJ CMU OR BRICK NEW CONSTRUCTION - SHOWN SOLID BTWN. BETWEEN F.I.O. FURNISHED AND INSTALLED MIN. MINIMUM REINF. REINFORCING W/O WITHOUT 2 WINDOW, RELITE OR 1/8" PER FOOT PLYWOOD CB CATCH BASIN BY OWNER M.I.P. METAL INSULATTED PANEL REDID. RE❑UIRED WD. WOOD A7.01 LOUVER MARK RIGID INSULATION C.G. CORNER GUARD FIN. FINISH MISC. MISCELLANEOUS R.O. ROUGH OPENING WDW. WINDOW _SHEET WHERE DRAWN WINDOW C.I. C.I.P. CAST IRON F.R.P.P. FIBER REINFORCED PLASTIC M.O. CAST IN PLACE PANEL S M.R. MASONRY OPENING SCHED. SCHEDULE MOISTURE RESISTANT S.C. SOLID CORE WHS. W.P. WELDED HEAD STUD WATERPROOF 14 NUMBER - REFER SPRINKLER MAIN _ BATT INSULATION C.L. CENTER LINE FRT. FIRE RETARDANT TREATED MULL. MULLION SHT. SHEET W.R. WATER RESISTANT BUILDING SECTION TO SCHEDULE - - - - - - - - - WOOD MEMBER CLR. CLG. CMU CLEAR FTG. FOOTING CEILING GA. GAUGE CONCRETE MASONRY UNIT GALV. GALVANI ED MTD. MTG. MTL. MOUNTED SIM. SIMILAR MOUNTING S.I.O. SUPPLIED AND INSTALLED METAL BY OWNER WT. WEIGHT W.W.F. WELDED WIRE FABRIC Y.D. YARD DRAIN DETAIL IDENTIFICATION 6 E UIPMENT MARK PROPERTY LINE EXISTING CONSTRUCTION TO REMAIN - SHOWN LIGHT BACKGROUND WOOD BLOCKING COL. COLUMN G.C. GENERAL CONTRACTOR N.I.C. CONC. CONCRETE GWB GYPSUM WALLBOARD, GYPSUM NOM. NOT IN CONTRACT S.I.V. SUPPLIED AND INSTALLED NOMINAL BY VENDOR A3.01 E UIPMENT SHEET WHERE DRAWN NUMBER - REFER (�rTO �� 0 FINISHED WOOD CONT. CONTINUOUS BOARD N.T.S. NOT TO SCALE S.O.I.C. SUPPLIED BY OWNER INSTALLED SCHEDULE FENCE 0 ACOUSTICAL TILE CONSTR. CONSTRUCTION H.B. HOSE BIBB O.A. OVERALL BY CONTRACTOR EXTERIOR ELEVATION X X X STEEL CONTR. C.T. CONTRACTOR H.C. HANDICAPPED CERAMIC TILE H.M. HOLLOW METAL O.C. O.D. ON CENTER S . S UARE OVERFLOW DRAIN S.S. SERVICE SINK, SANITARY SEWER DETAIL IDENTIFICATION ROOM MARK �� DBL DOUBLE HORI HORI ONTAL O.H. OVERHEAD SST STAINLESS STEEL 8 ROOM -ROOM NAME EXISTING CONSTRUCTION TO BE ALUMINUM . WHERE DRAWN BREAKLINE DIM. DIMENSION H.P. HIGH POINT OP'G OPENING STD. STANDARD A3.02 SHEET 100 0~ROOM NUMBER / \ REMOVED:- SHOWN DASHED E.I.F.S. J DTL. DETAIL HT. HEIGHT OPP. OPPOSITE STL. STEEL V- D.F. D.S. DRINKING FOUNTAIN HTR. HEATER DOWNSPOUT HVAC HEATING, VENTILATION, PTN. AND PERP. PARTITION STRUCT. STRUCTURE, STRUCTURAL PERPENDICULAR SUSP. SUSPENDED n L SOUND INSULATION DWG. DRAWING AIR CONDITIONING PL. PLATE, PROPERTY LINE SYS. SYSTEM INTERIOR ELEVATION COLUMN GRIDS WALL TYPE MARK R E S U B M EA. E.F.S. EACH IBC INTERNATIONAL BUILDING CODE PLAS.LAM. EXTERIOR FINISH SYSTEM INSUL. INSULATION PLYWD. PLASTIC LAMINATE T TREAD, TOP PLYWOOD T.O.J. TOP OF JOIST 5 DETAIL IDENTIFICATION WALL TYPE E.I.F.S. EXTERIOR INSULATION AND INT. INTERIOR PLBG. PLUMBING T.O.M. TOP OF MASONRY 5.03 6 FINISH SYSTEM JT./JTS. JOINT, JOINTS PNL. PANEL, PANELING T.O.P. TOP OF PARAPET B X O FE FIRE EXTINGUISHER 7 SHEET WHERE DRAWN X NOTE Dec 11 2 4 5 0 7 0 10 12 13 14 15 Mi Chalateca 1610 S. 341 st Place Suite 8 A Federal Way, WA 98003 i Smith C *0 603 Stewart Street suite 610 C Seattle, Washington 98101 206.466.5239 p 206.713.4076 m ksmith@smithco.org http://www.smithco.org/ Consultant D E Consultant Registration F Architect Registration 6294 G REGISTERED ARCHITECT KEITH L. SMITH STATE OF WASHINGTON H Issues and Revisions No. Date Issues 1 10,15,20 PERMIT 2 12,02,20 PERMIT CERRECTIENS I J Project Name Project Number 02016063.01 Description COVER SHEET K Computer File G-1.1.DWG Scale AS NOTED Template All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the TT D property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, Larrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose 020 whatsoever without the written permission of smith co. 11 c. CITY OF FEDERAL WA G�lx