20-104064-CO-WSEC Forms (Energy Forms)-10-21-2020-V120-104-COMSEC Forms (Energy Forms)-10-21-2020-V1
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories
RECEIVED
1
AY
M NIT MENT
Project Info
Project Title: 1610 S. 341st Place, Federal Way, WA 98003
Date .
Compliance
Applicant Information. Provide contact information for individual Mo can
For Building Department Use
forms do not
respond to inquiries about compliance form information provided.
Company Name: smith co Ilc
require a
password to
Company Address: 603 Stewart Street, Suite 610, Seattle, WA 98101
use.
Instructional and
Applicant Name: Keith L. Smith
calculating cells
are write -
Applicant Phone: 206-713-4076
protected.
Applicant Email: ksmith@smithco.org
Project Description
0 New Building 0 Addition Alteration 0 Plans Included
Include PROJ-SUM form (included in envelope forms vtorkbook) vteth lighting complliance forms.
Building Additions
Compliance Method Interior lighting Exterior lighting
Lighting systems in addition area comply with all applicable
provisions as a stand alone new construction project
Refer to Section C502.2.6 for additional
- -
requirements.
Lighting systems in addition are combined with existing
building lighting systems to demonstrate compliance
Addition is combined with existing:
For interior lighting projects, include new + existing interior lighting fixture wattage in Proposed
Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form.
For exterior lighting projects, include new + existing exterior lighting fixture vtettage in Proposed
Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG-EXT form.
Interior and Exterior
Lighting Power
Interior lighting
Parking garage
Exterior lighting
Lighting Alterations
50% or more of existing are replaced
-
0
-
0
---------------
0
Select all Lighting Power and Lighting
Control elements that apply to the scope
Less than 50% of existing are replaced
................
0
---------
0
.............................
0
of the retrofit project. If project includes a
Lamp and/or ballast replacement only
combination of spaces where less than
50% of the existing fixtures are replaced
-existing total wattage not increased
in some spaces, and 50% or more of the
fixtures are replaced in others, then
50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply vuth
provide separate lighting povier
total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in
compliance forms for the tvto retrofit
Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form.
conditions. Spaces undergoing the same
Less than 50% replaced - Total lighting poorer of new + existing -to -remain fixtures shall not exceed
type of retrofit may be combined into one
the total lighting pouter prior to alteration. Include new + existing -to -remain fixtures in the Proposed
lighting pouter compliance form.
Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form.
50% threshold applies to numberof luminaires for interior spaces and parking garages, and total
Refer to Section C503.6 for additional
installed vtettage for exterior luminaires.
requirements.
Lighting Controls
Interior lighting
Parking garage
Exterior lighting
All alteration lighting controls shall be
New wiring installed to serve added
commissioned perC408.3.
fixtures and/or fixtures relocated to
0
0
new circuit(s)
New or moved lighting panel 0 013
........................................................................... ----------------
Interior space is reconfigured -
13
luminaires unchanged or relocated
................................................................................................. .- -.................. ................- --------------- ----
Newwiring orcircuit - For interior lighting, provide required manual controls perC405.2.3,
occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application
0 No changes are being made to
specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7.
the interior or exterior lighting
New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic
systems and existing space
time svutch controls per C405.2.2.
uses and configuration are not
Reconfigured interior space - Provide all required lighting controls that apply to a new interior
changed.
space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured
Change of Space Use
0 Existing interior lighting systems in areas under -going a change in space use are upgraded to
comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2).
Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage
table in LTG-INT-BLD or L TG-IN T-SPA CE form.
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016
Project Title: 1610 S. 341st Place, Federal Way, WA 98003
Date 10 .20 .20
Interior Lighting System
track lighting in retail portion of project as well as track used in food prep areas, pendant
Description
lighting over service counter and standard recessed cans in toilet. All lighting to be LED
Interior Lighting Power
0 Building Area Method Space -by -space Method
Allowance Method
Select method used in project.
Interior Lighting Controls
All C405.2.1- C405.2.8 Controls 0 C405.2 Exception 5 Luminaire Level
Lighting Control (LLLC)
0 Additional Efficiency Package Option
C406.4 Enhanced digital lighting controls
To comply with C406.4, no less than 90% of the total installed interior lighting povler shall comply with
required controls per C406.4.
Dwelling Unit Interior
Permanently installed interior lighting fixtures in dvtelling units comply vuth:
Lighting
O C405.2 thru C405.5 Commercial Lighting Controls and LPA
O C406.3 High Efficacy Lighting
O
Exterior Lighting System
Description
2015 Washinqton State Enerqv Code Compliance Forms for Commercial Buildinqs includinq R2, R3, R4 over 3 stories and all R1 Revised Auqust 2016
Project Title: 1610 S. 341st Place, Federal Way, WA 98003
Date 10.20.20
Calculation
Q Q Addition - O Addition
For Building Department Use
Area NOTES
stand alone + existing
O Spaces where < 50% of O Spaces where z 50% of O
luminaires are replaced luminaires are replaced
LPA
40 Standard Q Additional Efficiency Package Option O
Calculation
C406.3 Reduced Interior Lighting
Type
To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA.
Refer to C406.3 for additional requirements.
Maximum Allowed Lighting Wattage "OTEt
Location (plan #,
Ceiling
Gross Interior
Allowed
Watts Allowed
room #)
Space Type
HeightNOTE2
Area in ft2
Watts per ft2
(watts/ft2 x area)
dining
Dining area: Family dining area
23
968
0.753
729
food prep
Food preparation
10
1322
0.790
1044
toilet
Restroom: all other
8
90
0.780
70
Total Area 2380
Retail Display Allowance from LTG-INT-DISPLAY
LobbyArt/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE a� Allowed Watts 1844
Proposed Lighting Wattage NOTES
Location (plan #,
room #)
Fixture Description NOTE 4, 5, 6
Number of
Fixtures
Watts/
Fixture NOTE
Watts
Proposed
service counter
pendant
10
32
320
kitchen
2x4 led troffers
11
36
396
toilet
recessed can
11
16
176
dining
pendant
21
32
672
Proposed Retail Display Lighting from LTG-INT-DISPLAY
Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts
1 1564
Interior Lighting Power Allowance COMPLIES
Note 1 - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu.
Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f.
Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures.
Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included).
For
track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank.
Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as
existing
in fixture description.
Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For
luminaires with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low
voltage
lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or
50
wettsAineal foot, or enter the wattage limit of permanent current limiting device.
Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage.
Note 9 - Calculation Area Details:
a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building
lighting systems to demonstrate compliance. Refer to C502.1.