Loading...
22-100523-Infrastructure Upgrades-2-8-2022-V1N O NI H Z_ a) co L 0) Q U 7 L co L w L co Y of 0 N N M rl- U) a� a m L U 7 U) ❑ w w L (D Y 0 0 N N C' ) 0 M 2 m A B C D E F Cl) _l F )fit CL O 2 1 Q 0 VD ❑ KAISER PERMANENTE 0 61 301 S 321 OTH ST FEDERAL WAY WA 7043 REGISTERED ARCHITECT 7 R. David Frum STATE OF WASHINGTON ARCHITECTURAL SET 2/2/2022 W Z W Z w Q Q PROJECT LOCATION PROJECT TEAM SHEET INDEX & ISSUE SCHEDULE Q ADDRESS: KEY PLAN 301 S 320TH ST CLIENT NAME KAISER PERMANENTE OF WASHINGTON 1300 SW 27TH ST MARLENE STUTZMAN 206-724-4531 ARCHITECTURAL uj Lu FEDERAL WAY, WA 98003 RENTON, WA 98507-2435 Marlene.C.Stutzman@kp.org CP1.1 FIRST FLOOR CODE PLAN ^ Q I..L H AREA OF WORK A1.1 FIRST FLOOR PLAN U w o s3 ARCHITECT DLR GROUP BENJAMIN PASCHKE A2.1 ENLARGED FLOOR PLANS � 00 51 UNIVERSITY ST #600 SEATTLE, WA 98101 206-957-1903 bpaschke@dlrgroup.com A8.2 DOOR & FRAME TYPE & SCHEDULE U) Q w T_ � 5 320Ih St 2�"� 53201"� � S320t"532�" GENERAL CONTRACTOR HOWARD S. WRIGHT BOB GREENE � O } Q LL Z N 415 1STAVE NORTH, SUITE 400 SEATTLE, WA 98109 206-473 7675 BGreene@hswc.com Z) Q Q 0w W ❑ LU IL o LL S321MP% K 5 - $ 5333N ST p y PERMIT SET N sw 323y .,, q r 53 2/7/2022 REVISIONS - $g 33351h 1n r� $ 324m ¢ LL1 % � x m nDVERTIS X PROJECT INFORMATION SCOPE OF WORK: INSTALLATION OF 2 NEW DOORS AND A WOOD GOVERNING 2018 IBC WITH WA STATE AMENDMENTS PARITION WALL TO THE INJECTION AREAS, BUILDING CODES: 2018 IFC REPLACEMENT AND UPGRADE OF DOOR PANELS AND LIKE HARDWARE AT SEVERAL LOCATIONS BUILDING OWNER: KAISER PERMANENTE OF WASHINGTON 5 1300 SW 27TH ST, RENTON WA 98507-2435 LEGAL DESCRIPTION: N 1/2 OF E 3/4 OF NW 1/4 OF NW 1/4 LESS POR LY SLY OF 73-22116-00 LN DAF BEG SW COR OF E 1/4 OF SD N 1/2 TH N ALG W LN OF SD E 1/4 60 FT TO TPOB OF SD LN TH N 88-52-32 W TAP COVER SHEET PROJECT SIZE: 600 SF 100 FT E OF W LN OF SD E 3/4 TH S 01-02-52 W TO S LN OF SDN1/2THWILY ALGSDSLNTOWLNOFSDE3/4& CONSTRUCTION TYPE: V-A TERMINUS OF SD LN TGW S 60 FT OF W 1/2 OF NW 1/4 OF SD NW 1/4 OF NW 1/4 LESS CO RDS & LESS C/M RGTS - AKA LOT OCCUPANCY TYPE: B - MEDICAL OFFICE/ BUSINESS 1 KCLLA 8906017 APPROVED 1-2-90 RECEIVED FULLY SPRINKLERED: YES PARCEL NUMBER: 172104-9105 N 0 NUMBER OF STORIES: 1 Feb 09 2022 G0.1 v N CITY OF FEDERAL WAY N COMMUNITY DEVELOPMENT N n n n n r r N 0 N �I Z_ I N m 0) n N U 7 i i w C 0 W LL Y 0 0 N N co N i Q U i C 0 W L� N Y 0 0 N N co 0 co n n n n r r N O N �I Z_ N co L 0) Q L U 7 L co L W L co Y 0 0 N N M rl— N (6 L O Q L U 7 L U) L ❑ W L Y O O N N M O O M 2 m A I B I C D I E F 3 El 5 114 (T-) ENLARGED FLOOR PLAN, LEVEL 1, AREA 1 SCALE: 1/4" = 1'-0" ENLARGED FLOOR PLAN, LEVEL 1, AREA 4 SCALE: 1/4" = 1'-0" L A Lo ENLARGED FLOOR PLAN, LEVEL 1, AREA 3 SCALE: 1/4" = 1'-0" N ENLARGED FLOOR PLAN, LEVEL 1, AREA 2 SCALE: 1/4" = 1'-0" GENERAL ARCHITECTURAL NOTES 1. WALL TYPES SHALL BE DESIGNATED ON FLOOR PLANS THUS: XX. X. XX` SEE SHEET XX.X FOR WALL TYPES. ALL INTERIOR PARTITIONS ARE WALL TYPE XX.X.XX UNLESS NOTED OTHERWISE. 2. ALL MASONRY WALLS AND INTERIOR STUD WALLS SHALL EXTEND TO UNDERSIDE OF FLOOR OR ROOF DECK ABOVE UNLESS NOTED OTHERWISE. SEE REFLECTED CEILING PLAN NOTES. 3. PROVISIONS SHALL BE MADE AT ALL FULL HEIGHT NON - BEARING WALLS FOR 1-INCH VERTICAL MOVEMENT OF THE BUILDING STRUCTURE WITHOUT TRANSFER OF COMPRESSIVE LOADS TO WALL. FILL IRREGULARITIES BETWEEN TOP OF WALL AND DECK ABOVE WITH MINERAL WOOL INSULATION OR FIRE STOPPING MATERIALS AS REQUIRED TO MEET FIRE RATING OF RESPECTIVE WALLS. SEE DETAILS ON SHEET XX.X. 4. GYPSUM BOARD SURFACES SHALL BE ISOLATED WITH CONTROL JOINTS WHERE SHOWN ON DRAWINGS AND AS DESCRIBED IN THE SPECIFICATIONS. 5. SCRIBE GYPSUM WALL BOARD OF WALLS AND PARTITIONS TO IRREGULARITIES OF DECK ABOVE. SEAL TIGHTLY AROUND ALL PENETRATIONS. 6. PROVIDE SEISMIC BRACING FOR SUSPENDED CEILINGS OR AS SHOWN ON THE DRAWINGS. FLOOR PLAN LEGEND ftAREA NOT IN CONTRACT (NIC) 0 NEW PARTITION r —, FURNITURE WALL SYSTEM (BY OTHERS) 0 EXISTING PARTITION TO REMAIN 213 SLIDING DOOR IDENTIFIER, SEE DOOR SCHEDULE SHEET A9.1 FEC FIRE EXTINGUISHER CABINET 0 EXISTING GYP. BD. COLUMN ENCLOSURE TO REMAIN N NEW 4X8 FIRETREATED TELEPHONE o BACKBOARD MOUNTED VERTICAL, JUST BELOW CEILING NOTE TEXT 0 DIMENSION / LEADERS E-1 ALIGN FACES f�-- PARTITIONS CENTERED ON MULLION MW 01 PLUMBING, ACCESSORIES, & EQUIPMENT SYMBOL CGD �� CORNER GUARDS CR CARD READERS RS ROOM SCHEDULER OBJECT NOTATIONS: E EXISTING R RELOCATED N NEW RECEIVED Feb 09 2022 7043 0- Z5 0 (D ry J 0 0 REGISTERED ARCHITECT L R. David Fxum STATE OF WASHINGTON w z w z 73 ry w W ry CD IZ D W ry H U ry ILL z 0 LLJ IL PERMIT SET 2/7/2022 REVISIONS 73-22116-00 �- co w0 w0 �00 G) cn Q O} N Q co Q OIr Q O W (`') LL ENLARGED FLOOR PLANS CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT A2.1 N 0 N �I Z_ I N m 0) n N U 7 i i w C 0 W LL Y 0 0 N N co N i Q U i C 0 W L� N Y 0 0 N N co 0 co A B C D E F DOOR AND FRAME SCHEDULE DOOR PANEL TYPES Cn PANEL FRAME DETAILS NO. OF FIRE UMBER PANELS WIDTH HEIGHT THICKNESS MATERIAL FINISH GLASS TYPE MATERIAL TYPE RATING HARDWARE SET HEAD JAMB LEFT JAMB RIGHT COMMENTS N C N �I z m m 0) Q w 0 w Y C� C N N cl) n U 0 w Y C C N N 0 GJ co ra D100C3 1 T- 0" T- 0" 1 3/4" WD F HM HW-01 D100C4 1 T- 0" T- 0" 1 3/4" WD F HM HW-01 G100C2 1 T- 0" T- 0" 1 3/4" WD F HM HW-04 G102 1 T- 0" 7' - 0" 1 3/4" WD F HM HW-05 INSTALL NEW AUTOMATIC DOOR OPENING STICKERS G103 1 3' - 0" T- 0" 1 3/4" WD F HM HW-05 INSTALL NEW AUTOMATIC DOOR OPENING STICKERS K100C1 1 3' - 6" T - 0" 1 3/4" WD F HM 1 HW-07 K100C2 1 T- 4" T - 0" 1 3/4" WD N HM HW-08 K100C3 1 T - 0" T- 0" 1 3/4" WD F HM 1 HW-07 K103A 1 2' - 8" T- 0" 1 3/4" WD N HM HW-10 K103B 1 T- 0" T- 0" 1 3/4" WD F HM HW-08 INSTALL NEW CLOSER COVER L101 1 T- 0" T- 0" 1 3/4" WD F HM HW-13 L101A 1 T- 0" T- 0" 1 3/4" WD F HM HW-12 M100C2 1 T- 0" T- 0" 1 3/4" WD N HM HW-14 INSTALL NEW CLOSER COVER M102 1 2' - 8" T- 0" 1 3/4" WD F HM HW-15 M103 1 2' - 8" T- 0" 1 3/4" WD F HM (E) v / O O O � 0 FLUSH PANEL NARROW LITE O SOLID CORE WOOD GLASS IN SOLID CORE WOOD Lj 61 FRAME TYPES 7043 REGISTERED ARCHITECT R. David Fxum STATE OF WASHINGTON O DOOR AND FRAME SCHEDULE GENERAL NOTES HOSPITAL DOOR FRAME 2 A. ALL EXTERIOR HOLLOW METAL FRAMES SHALL BE FILLED WITH INSULATION. B. ALL INTERIOR HOLLOW METAL FRAMES SET IN MASONRY AND DOOR HARDWARE GROUPS CONCRETE WALLS E O C. NTED METAOLLSTUD WALLS ALL HOLLOW ME ALSHALL FRAMES SET SHALL BE FILLED WITH MINERAL WOOL BLANKET INSULATION. NOTE: THE HARDWARE GROUPS BELOW DEFINE DESIGN INTENT; CONTRACTOR TO COORDINATE WITH OWNER TO VERIFY THAT (E) HARDWARE IS D. ALL EXTERIOR FRAMES SHALL BE INSTALLED WITH 1/4" SHIM ACCEPTABLE FOR RE -USE AND SEALANT AROUND PERIMETER OF FRAME. NOTE: THE CONTRACTOR IS TO CONFIRM HARDWARE COMPATIBILITY AND MAKE RECOMMENDATIONS IF DISCRPANCIES ARISE E. MASONRY LINTELS AND STEEL LINTELS ARE SHOWN ON NOTE: WHERE OPENING IS (E), VERIFY ALL CONDITIONS PRIOR TO ORDER STRUCTURAL DRAWINGS. F. GLASS TYPES FOR DOORS ARE INDICATED IN THE DOOR HW-011HW-02 HW-081HW-11 HW-13 GLAZING COLUMN OF THE DOOR AND FRAME SCHEDULE. 1 MORTISE STOREROOM LOCKSET W/ LEVER HANDLE 3 BALL BEARING HINGES, FULL MORTISE 1 CYLINDRICAL STOREROOM LOCK W/ LEVER HANDLE GLASS TYPES FOR FRAMES ARE INDICATED ON THE FRAME 1 ELECTRIC STRIKE & FACEPLATE 1 CYLINDRICAL STOREROOM LOCK W/ LEVER HANDLE 1 ELECTRIC STRIKE ELEVATIONS. 3 SILENCER 1 ELECTRIC STRIKE 1 WALL STOP G. FOR COILING DOORS, GRILLES AND SECTIONAL DOORS, WIDTH 1 CARD READER 1 SURFACE CLOSER 3 SILENCER AND HEIGHT DIMENSIONS SHOWN IN DOOR AND FRAME REUSE (E) FOR REMAINING HW 1 WALL STOP 1 CARD READER SCHEDULE REPRESENT FINISHED OPENING SIZE. 3 SILENCER REUSE (E) FOR REMAINING HW CONTRACTOR TO COORDINATE EXACT SIZE OF DOOR WITH HW-04 1 CARD READER MANUFACTURER. 3 BALL BEARING HINGES, FULL MORTISE REUSE (E) FOR REMAINING HW HW-14 H. FRAME MANUFACTURER SHALL COORDINATE LOCATIONS OF 1 CYLINDRICAL STOREROOM LOCK W/ LEVER HANDLE 1 ELECTRIC STRIKE ALL CONCEALED CONDUIT AND J-BOXES REQUIRED FOR 1 SURFACE CLOSER HW-10 1 CLOSER COVER ONLY SECURITY SYSTEM HARDWARE PRIOR TO MANUFACTURING OF 3 SILENCERS 1 CYLINDRICAL STOREROOM LOCK W/ LEVER HANDLE 3 SILENCER HOLLOW METAL FRAMES AND COORDINATE WITH SECURITY REUSE (E) FOR REMAINING HW 1 ELECTRIC STRIKE 1 CARD READER HARDWARE AND DEVICES. 1 CLOSER COVER ONLY REUSE (E) FOR REMAINING HW I. PROVIDE HEAD RECEIVERS AT ALUMINUM STOREFRONTS AND HW-051HW-06 1 WALL STOP CURTAIN WALLS AS REQUIRED FOR STRUCTURAL DEFLECTION 1 AUTOMATIC DOOR DECAL 3 SILENCER HW-15 ALLOWANCE. REUSE (E) FOR REMAINING HW 1 CARD READER 3 BALL BEARING HINGES, FULL MORTISE J. SEE SPECIFICATIONS HARDWARE SECTION FOR HARDWARE REUSE (E) FOR REMAINING HW 1 CYLINDRICAL PRIVACY LOCK W/ LEVER HANDLE SETS NOTED IN DOOR AND FRAME SCHEDULE. HW-071HW-09 1 WALL STOP 3 BALL BEARING HINGES, FULL MORTISE HW-12 3 SILENCER 1 CYLINDRICAL STOREROOM LOCK W/ LEVER HANDLE 3 BALL BEARING HINGES, FULL MORTISE REUSE (E) FOR REMAINING HW DOOR AND FRAME GENERAL 1 ELECTRIC STRIKE & FACEPLATE 1 CYLINDRICAL STOREROOM LOCK W/ LEVER HANDLE 1 SURFACE CLOSER 1 ELECTRIC STRIKE NOTES 1 WALL STOP 1 SURFACE CLOSER 3 SILENCER 3 SILENCER 1 CARD READER 1 CARD READER A. DOOR AND FRAME ASSEMBLIES SHALL COMPLY WITH ALL REUSE (E) FOR REMAINING HW SCHEDULED REQUIREMENTS, GENERAL NOTES & LEGENDS, 3 DOOR AND FRAME DETAILS, AND PROJECT SPECIFICATIONS. B. CONTRACTOR TO COORDINATE DOOR HARDWARE HANDING & SIZING, AND INTEROPERABILITY OF COMPONENTS BASED ON SCHEDULED HARDWARE MANUFACTURERS DOCUMENTATION AND CORRESPONDING DETAILS. DOOR HARDWARE INFORMATION FRAME DETAILS C. ALL RATED DOOR &FRAME ASSEMBLIES SHALL INCLUDE ALL HARDWARE REQUIRED FOR RATING, WHICH SHALL BE UL APPROVED AND LABELED D. COORDINATE TENANT KEYWAYS WITH BUILDING ENGINEER FINISH: BUILDING STANDARD - US26D OR SIM AND TENANT REQUIREMENTS E. ALL ALUMINUM DOOR FRAMES SHALL BE "WESTERN LEVER/ROSE STYLE: SARGENT B LEVER / LN ROSE INTEGRATED", "WILSON PARTITIONS", OR EQUAL. BUTT HINGES: MCKINNEY TA2714 - 4.5" x 4.5" F. ALL HARDWARE TO BE COMPLIANT WITH ADA TITLE III / METAL STUD WALL SEE PLANS STATE/LOCAL CODES AND ORDINANCES (I.E. LEVEL HANDLES & MORTISE LOCKSET: FOR WALL TYPES COMPLIANT CLOSERS, ETC) STOREROOM LOCKSET: EQUAL TO SARGENT 8204 G. KEYING SHALL BE PROVIDED BY GENERAL CONTRACTOR, WALL WHERE OCCURS KEYING MATRIX IS TO BE COORDINATED WITH BUILDING CYLINDRICAL LOCKSET: MANAGEMENT AND TENANT. UNO SEE PLAN STOREROOM LOCKSET: EQUAL TO SCHLAGE ND80 ACOUSTICAL SOUND BATT H. CARD READER MOTION DETECTOR MAGNETIC LOCKS AND PRIVACY LOCKSET: EQUAL TO SCHLAGE ND40 INSULATION LOCKS TO BE PROVIDED BY THE TENANT SECURITY VENDOR ELECTRIC STRIKE: HES 1006 OR ALARM CONTROLS AES 30012M2 GENRAL CONNTRACTOR IS TO COORDINATE SECURITY WITH BUILDING MANAGEMENT. W' ' I FACEPLATE: HES KM OR HES J I. FINISH OF ALL SURFACE MOUNTED CLOSERS ARE TO MATCH FINISH FRAME OF DOOR FRAME. CARD READER - SURFACE CLOSER: LCN CLOSERS 4040XP = " 1/2 - - 1 /2" J. PAINTED DOORS AND FRAMES ARE TO BE PAINTED SEMI - Z v - - GLOSS PAINT TO MATCH ADJACENT WALL SURFACES, UNLESS � — - WALL STOP: IVES WS407CCV _ - SEALANT BOTH SIDES TYP N E. NOTED OTHERWISE. 0 0 S uj K. ALL DOOR HARDWARE FINISH SHALL BE: FILL-IN FINISH SILENCERS: IVES SR64-GRY -- - ALUMINUM KNOCK DOWN FRAME Z (n - W CARD READER: BY OTHERS C 0 S SEE DOOR AND FRAME SCHED. 0 Q AUTOMATIC DOOR DECAL: NORTON ADA 1014 G � SILL AND COMPRESSION M ANCHORS AS OCCUR W W� 4 DOOR - SEE DOOR AND n FRAME SCHED. U wC wC Ico GLAZING TYPE DESCRIPTIONS co W Q CD CD< N CARD READER LOCATION, TYP 1 ALUM KNOCK DOWN DR FRAME -HEAD/JAMB CG CIG CLEAR FLOAT GLASS CLEAR INSULATING GLASS z j Q < — OLU SCALE: 3/4" = V-0" A8.2 ' SCALE: 3" = 1' 0" CTG CLEAR TEMPERED FLOAT GLASSILL 0 CTIG CLEAR TEMPERED INSULATING GLASS IL U- GL GLASS IIP INSULATED INFILL PANEL GLASS LG LAMINATED GLASS PG PATTERN GLASS PIG PATTERN INSULATING GLASS SG SPANDREL GLASS TFG TINTED FLOAT GLASS PERMIT SET TG TEMPERED GLASS TIG TINTED INSULATING GLASS 2/7/2022 TTG TINTED TEMPERED FLOAT GLASS REVISIONS TTIG TINTED TEMPERED INSULATING GLASS WG POLISHED WIRE GLASS DOOR/FRAME FINISH LEGEND BAA BRONZE ANODIZED ALUMINUM CAA CLEAR ANODIZED ALUMINUM P-XX PAINT - SEMI -GLOSS FINISH PL PLASTIC LAMINATE ST STAINED WOOD VENEER 5 AL ALUMINUM GL GLASS HM HOLLOW METAIL DOOR & FRAME ASSEMBLY 73-22116-00 SCW SOLID CORE WOOD DOOR & FRAME TYPE & SCHEDULE RECEIVED Feb 09 2022 A8.2 N CITY OF FEDERAL WAY N N COMMUNITY DEVELOPMENT N