22-100668-SITE PLANGENERAL NOTES
BARRY-WHEMILLER
1. CONTRACTOR SHALL COMPLY WITH THE CURRENT "GENERAL CONDITIONS," AND BUILDING STANDARDS AS PROVIDED BY
THE BUILDING OWNER.
32001 32ND AVE.
S.
SUITE 340,
FEDERAL WAY, WA
98001
2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF DIFFERENT TRADES.
ARCH / INTERIOR ABBREVIATIONS
BUILDING SUMMARY
PROJECT TEAM
3. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS.
4. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER AND ARCHITECT FOR APPROVAL PRIOR
TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWING ONLY WILL NOT SATISFY THIS REQUIREMENT.
A.B.
ANCHOR BOLT
F.R.
FIRE RESISTIVE
P.
PAINT
1. PROJECT ADDRESS:
TENANT:
GENERAL CONTRACTOR:
5. ALL MODIFICATIONS, REQUIRING OWNER OR ARCHITECT APPROVAL WILL NOT BE VALID UNLESS AUTHORIZED IN WRITING BY
A.C.P.
ACOUSTICAL CEILING
F.R.P.
FIBERGLASS- REINFORCED
PART.
PARTITION
BARRY-WEHMILLER
BARRY WEHMILLER
TBD - BIDDER DESIGN BUILD BY G.C.
OWNER AND/OR ARCHITECT.
A.C.T.
PANEL
ACOUSTICAL CEILING TILE
F.S.
PANEL
FULL SIZE
PBD.
PC.
PARTICLEBOARD
PIECE
32001 32ND AVE S., SUITE 340
CURRENT ADDRESS
A.F.F.
ABOVE FINISH FLOOR
FDN.
FOUNDATION
PERF.
PERFORATED
FEDERAL WAY, WA 98001
CITY, STATE ZIPCODE
PLUMBING ENGINEER:
6. WITHIN FIVE (5) BUSINESS DAYS OF START OF CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY IN WRITING BOTH THE
A.P.C.
ACOUSTICAL PANEL
FIN.
FINISH
PERP.
PERPENDICULAR
TBD - BIDDER DESIGN BUILD BY G.C.
ARCHITECT AND OWNER OF ANY ITEMS WHOSE ESTIMATED DELIVERY TO THE SITE WOULD BE LATER THAN THAT REQUIRED
CEILING
FIXT.
FIXTURE
PL.
PLATE
2. APPLICABLE CODES & ORDINANCES:
ARCHITECT/DESIGNER:
FOR TIMELY INSTALLATION IN THE CONSTRUCTION SEQUENCE SUBSTITUTION OF ALTERNATE ITEMS WITH SHORTER LEAD
A.T.
ACOUSTICAL TILE
FLASH
FLASHING
PLAM.
PLASTIC LAMINATE
2018 INTERNATIONAL BUILDING CODE WITH STATEWIDE AMENDMENTS
BURGESS INTERIOR ARCHITECTURE
MECHANICAL ENGINEER:
TIMES, PAYMENT OF RUSH FABRICATION OR DELIVERY CHARGES OUT OF SEQUENCE INSTALLATION, OR DELAY OF
ACOUS.
ACOUSTICAL
FLDG.
FOLDING
PLAS.
PLASTER
2018 INTERNATIONAL MECHANICAL CODE WITH STATEWIDE AMENDMENTS
1326 FIFTH AVENUE, SUITE 400
TBD - BIDDER DESIGN BUILD BY G.C.
INSTALLATION OPTIONS TO BE AT THE SOLE APPROVAL OF OWNER OR ARCHITECT.
ADJ.
ADJACENT
FLR.
FLOOR
PLBG.
PLUMBING
2018 INTERNATIONAL FUEL GAS CODE
SEATTLE, WASHINGTON 98101
7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH THE LATEST
ADJST.
ALT.
ADJUSTABLE
ALTERNATE
FLUOR.
FR.
FLUORESCENT
FRAME OR FRAMING
PLYWD.
PNL.
PLYWOOD
PANEL
2018 INTERNATIONAL FIRE CODE WITH STATEWIDE AMENDMENTS
TEL: 206.587.7120
ELECTRICAL ENGINEER:
LOCAL BUILDING CODES AND ORDINANCES.
AL.
ALUMINUM
FT.
FEET OR FOOT
PR.
PAIR
2018 WASHINGTON STATE COMMERCIAL ENERGY CODE
ATTN: MATIN AHMADPANAH
TBD - BIDDER DESIGN BUILD BY G.C.
AN.
ANODIZED
FTG.
FOOTING
PRCST.
PRECAST
2018 UNIFORM PLUMBING CODE WITH STATEWIDE AMENDMENTS
EMAIL: matina@burgesspnw.com
8. CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND SHALL REPORT ANY CONFLICTS OR QUESTIONS
APPROX.
APPROXIMATELY
FURR.
FURRING
PT.
PAINT OR POINT
2018 INTERNATIONAL EXISTING BUILDING CODE WITH STATEWIDE AMENDMENTS
FIRE/LIFE SAFETY ENGINEER:
FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK. DO NOT SCALE THE DRAWINGS.
ARCH.
ARCHITECTURAL
FLIT.
FUTURE
PTN.
PARTITION
2009 ICC/ANSI Al 17.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
BUILDING MANAGER:
TBD - BIDDER DESIGN BUILD BY G.C.
9. THE USE OF WORD "PROVIDE" SHALL ALWAYS MEAN, "FURNISH AND INSTALL, CONNECT, OR SECURE" AS REQUIRED.
ASB.
A/V
ASSEMBLY
AUDIO / VISUAL
G.B.
GRAB BAR
QTY.
QUANITY
2020 NATIONAL ELECTRICAL CODE
STERLING REALTY
G.C.
GENERAL CONTRACTOR
777 108th Ave NE, Suite 2150
10. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN
B.O.C.
BOTTOM OF STRUCTURE
G.L.R.
GLU-LAM BEAM
(R)
RELOCATE
3. GENERAL BUILDING DESCRIPTION:
Bellevue, WA 98004
INSTRUCTIONS AND TRADE ASSOCIATES ACCEPTED STANDARDS.
B.P.
BUILDING STANDARD
GWB
GYPSUM WALLBOARD
R.
RISER
TYPE OF CONSTRUCTION: IIA
TEL: 425.455.8174
B.U.
BUILT-UP
GA.
GAUGE
R.D.
RIGHT HAND
FIRE RESISTIVE SYSTEM: SPRINKLERED PER NFPA13 QUICK RESPONSE HEADS
ATTN: NICK WARNER
11. CONTRACTOR SHALL PROVIDE A WRITTEN CONSTRUCTION SCHEDULE. THIS SCHEDULE SHALL INCLUDE DELIVERY LEAD
BD.
BTWN.
BOARD
BETWEEN
GALV.
GL.
GALVANIZED
GLASS
R.I.A.
R.O.
ROUGH -IN ONLY
ROUGH OPENING
OCCUPANCY TYPE:'B' OFFICE
EMAIL: Nickw @SterlingRealty.com
PLUMBING, MECHANICAL, ELECTRICAL,
TIMES OF CONSTRUCTION ITEMS, AND START AND COMPLETION DATES OF EACH PHASE. THE CONTRACTOR SHALL UPDATE
BLDG.
BUILDING
GND.
GROUND
RAID.
RADIUS
LIFE SAFETY PERMITS UNDER SEPARATE SUBMITTALS.
AND PROVIDE SUCH SCHEDULE ON A BIWEEKLY BASIS.
BLK.
BLOCK
GP.
GROUP
REF.
REFERENCE OR
4. FIRE RESISTIVE CONSTRUCTION REQUIREMENTS:
BLKG.
BLOCKING
GR.
GRADE
REFRIGERATOR
SHAFT ENCLOSURES: 2 HOUR
12. WORK MUST BE SCHEDULED WITH THE BUILDING MANAGEMENT TO AVOID DISRUPTION TO THE TENANTS.
BM.
BEAM
GYP.
GYPSUM
REINF.
REINFORCED OR
EXIT STAIR ENCLOSURES: 2 HOUR
BOT.
BOTTOM
REINFORCING
CORRIDORS: NON -RATED PER IBC TABLE 1020.1
13. ACCESS TO AND FROM THE PROJECT SITE, SPECIAL CONDITIONS, NOISY WORK, TIMING OF WORK, INTERRUPTION OF
BRKT.
BRACKET
H.
HIGH
REL.
RELOCATED
MECHANICAL AND ELECTRICAL SERVICES, RELOCATION OF EXISTING EQUIPMENT, CASEWORK, FIXTURES, FITTINGS, ETC.,
H.A.
HANDICAP OR HOLLOW
REM.
REMOVE
MUST BE COORDINATED WITH THE BUILDING MANAGEMENT.
C.B.
CATCH BASIN
CORE
REQ.
REQUIRED
5. CODE SUMMARY: REFER TO SHEET G1003
C.F.
CUBIC FEET OR FOOT
H.M.
HOLLOW METAL
REV.
REVISION
14. ADEQUATE CLEANUP, PROTECTION AND PLACEMENT OF ANY CEILING TILES AND/OR OTHER DISRUPTION TO THE ADJACENT
C.L.
CENTERLINE
H.R.
HAND RAIL
RM.
ROOM
6. PROJECT DESCRIPTION:
TENANT IMPROVEMENTS MUST BE REPLACED BEFORE BUSINESS HOURS OF THAT TENANT IN ORDER THAT THE OCCUPANT
C.M.A.
CONCRETE MASONRY
H.W.T.
HOT WATER TANK
RTD.
RATED
NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT: WORK INCLUDES NON-STRUCTURAL DEMOLITION,
WILL NOT BE INCONVENIENCED IN THE NORMAL CONTINUATION OF THEIR OFFICE HOURS.
UNITS
HBD.
HARDBOARD
NEW PARTITIONS, DOORS, SIDELIGHTS, CASEWORK AND FINISHES.
C.T.
CERAMIC TILE
HDR.
HEADER
S.C.
SOLID CORE
15. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT
C.Y.
CUBIC YARD(S)
HDW.
HARDWARE
S.D.
SMOKE DETECTOR
THEIR OWN EXPENSE. THIS INCLUDES ALL AREAS ON THE PREMISES SUCH AS: COMMON HALLWAYS, FREIGHT ELEVATOR
CAB.
CEM.
CABINET
CEMENT
HORIZ.
HR.
HORIZONTAL
HOUR
S.F.
S.S.
SQUARE FEET
STAINLESS STEEL
VESTIBULES, ETC.
CER.
CERAMIC
HT.
HEIGHT
S.V.
SHEET VINYL
CLG.
CEILING
HWD.
HARDWOOD
S.Y.
SQUARE YARDS
16. SCHEDULE THE USE OF THE ELEVATOR WITH BUILDING MANAGEMENT.
CLKG.
CAULKING
SCHED.
SCHEDULE
CLR.
CLEAR
INCL.
INCLUDED, INCLUDING
SCR.
SCREEN
17. UPON COMPLETION OF ALL CONSTRUCTION, THE CONTRACTOR SHALL SUPPLY THE LANDLORD WITH ONE SET OF
CNTR.
COUNTER
INFO.
INFORMATION
SECT.
SECTION
LEGAL DESCRIPTION / PARCEL N 0
D RAW I N G
INDEX
"RECORD" AS -BUILT DRAWINGS.
COL. COLUMN ININSULATION SH. SHELF
COMP. COMPOSITION INT.T. INTEGRAL INTERIOR SH.&P. SHELF AND POLE
18. ALL MATERIALS TO BE NEW LION.
CONC.
CONCRETE
SHT.
SHEET
.
COND.
CONDITION
JAN.
JANITOR
SHTH.
SHEATHING
SHEET
SHEET
REVISION
19. PATCH ALL DISTURBED AND/OR DAMAGED AREAS AS REQUIRED TO ACCOMPLISH NEW WORK AND AS REQUIRED FOR
CONF. CONFERENCE JST. JOIST SHWR. SHOWER
FINISHED APPEARANCE.
CONN.
CONNECTION
JT.
JOINT
SIM.
SIMILAR
PARCEL NUMBER: 215465 0010
SHEET TITLE
REVISION #
CONSTR.
CONSTRUCTION
SL.
SLOPE
NUMBER
ISSUED
DATE
20. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY BACKING, BLOCKING, AND FRAMING FOR LIGHT
CONT.
CONTINUOUS
K.D.
KNOCK -OUT
SPEC.
SPECIFICATION
LEGAL DESCRIPTION: EAST CAMPUS CORP PARK PAR 1-BSP PER FEDERAL WAY LLA #00-105943-SU REC
G1001
COVER SHEET /PROJECT INFORMATION
X
FIXTURES, ELECTRICAL FIXTURES, CASEWORK AND ALL OTHER ITEMS REQUIRING IT.
CONTR. CONTRACTOR KIT. KITCHEN SPKLR. SPRINKLER
#20010319900004
CORR.
CORRIDOR/CORRUGATED
SPKR.
SPEAKER
PROJECT NOTES
X
21. CONTRACTOR TO COORDINATE ALL FIRE ALARM WORK WITH BUILDING OWNER.
CPT. CARPET L.B. LAG BOLT SQ. SQUARE
PLat Block:G1002
CTR.
CENTER
L.F.
LINEAL FOOT
STD.
STANDARD
Plat Lot: A & B
G1003
CODE SUMMARY
X
22. ALL PAINT AND FINISH MATERIAL COLORS SHALL MATCH ARCHITECT'S CONTROL SAMPLES AND REQUIRE ARCHITECT'S
CTSK.
COUNTERSUNK
L.H.
L.L.
LEFT HAND
LIVE LOAD
STL.
STN.
STEEL
STAIN
STREET MAP
REVIEW PRIOR TO INSTALLATION. SUBMIT TO ARCHITECT THREE (3) COPIES FOR REVIEW.
D. DEEP OR DEPTH L.PT. LOW POINT STOR. STORAGE
D.A. DOUBLE ACTING LAB. LABORATORY STRUC. STRUCTURAL
ARCHITECTURE
23. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW ON CABINETWORK, MILLWORK AND ANY OTHER SPECIAL
D.F. DRINKING FOUNTAIN LAM. LAMINATE SURR. SURROUND
ITEMS REQUIRING CUSTOM SHOP FABRICATION. SUBMIT TO ARCHITECT AT LEAST THREE (3) COPIES FOR REVIEW.
D.P.
DAMPPROOFING
LAV.
LAVATORY
SUSP.
SUSPENDED
D.W.
DISHWASHER
LB.
POUND
SYMM.
SYMMETRICAL
PROJECT LOCATION
24. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN
DBL.
DOUBLE
LBL.
LABEL
SYS.
SYSTEM
I
A1101
X
IN FULL.
DEC.
DECORATIVE
LOC.
LOCATION
GSLabsTesting ! y
N-Federal LLL
DEMOLITION /CONSTRUCTION PLAN
DEMO. DEMOLISH OR DEMOLITION LVR. LOUVER T. TREAD
Way
25. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE LIST OF ABBREVIATIONS PROVIDED
DEPT.
DEPARTMENT
T.A.
TOILET ACCESSORY
a Indigo Urgent
deral Way
A1131
REFLECTED CEILING DEMOLITION PLAN / REFLECTED CEILING PLAN
X
IS NOT INTENDED TO BE A COMPLETE LIST. THE ARCHITECT WILL DEFINE THE INTENT OF ANY IN QUESTION.
DIA. DIAMETER M.D.F. MEDIUM DENSITY T.B.D. TO BE DETERMINED
DIAL.
DIAGONAL
FIBERBOARD
T.&G.
TONGUE AND GROOVE
,c
DIFF.
DIFFUSER
M.D.O.
M.E.
MEDIUM DENSITY OVERLAY
MATCH EXISTING
T.B.
TACK BOARD
A1161
POWER &DATA PLAN
X
SYMBOLS
DIM.
DISP.
DIMENSION
DISPENSER
M.H.
MANHOLE
T.O.
T.O.C.
TOP OF
TOP OF CURB ORay
r
Courtyardbyt
Seattle Feder
DN. DOWN M.O. MASONRY OPENING CONCRETE
DOCS. DOCUMENTS MACH. MACHINE T.O.S. TOP OF SLAB OR TOP OF
4.3*csozy
3-su`n t
INDICATES FINISHED
DR.
DOOR
MATL.
MATERIAL
STEEL
a-32"`s` "
AI200
ELEVATIONS
X
ELEVATION REFERENCE SYMBOL SURFACES TO ALIGN
DTL.
DETAIL
MAX.
MAXIMUM
T.O.P.
TOP OF PAVEMENT
S320thSt S320thSt. S320thS-t*
DWG. DRAWING MBR. MEMBER T.O.W. TOP OF WALL
U DETAIL ID
DRAWING TITLE BAR
EXISTING
MECH.
MEMB.
MECHANICAL
MEMBRANE
T.S.
T.V.
TUBE STEEL
TELEVISION
Federal way vet Center
L AI100 R
(E)
®
A1500
DETAILS
X
DETAIL IDENTIFICATION
E.W.
ELECTRICAL PANEL
MEZZ.
MEZZANINE
TEL.
TELEPHONE
ental Comm
Communications y
n
SHEET NO. DRAWING TITLE
EA.
EACH
MIN.
MINIMUM
TEMP.
TEMPERED OR TEMPORARY
r ie Sao Q ®Ellen Derrick
�AI600
SCALE
ELEC.
ELECTRICAL
MIN.
MINIMUM
TLT.
TOILET
IgelSi
DOOR SCHEDULE /SIDELIGHT &GLAZING SCHEDULE /DETAILS
X
FINISH PLAN
ELEV.
ELEVATION OR ELEVATOR
MIRR.
MIRROR
THR.
THRESHOLD
delS�ptlmoDfa...�
ptdvetiWe_
A1603
LIGHTING SUMMARY
X
SECTION REFERENCE SYMBOL /q
ENCL.
ENCLOSURE
MISC.
MISCELLANEOUS
TYP.
TYPICAL
Rockwell C Seattle Center
EQ. EQUAL MTD. MOUNTED
FLOOR ELEVATION SYMBOLS
EQPT.
EQUIPMENT
MTG.
MTL.
MOUNTING
METAL
U.L.
UNDERWRITERS
Air Force Officer,
DTL
EXH.
EXHAUST
LABORATORIES
space Force, and...
SHT NOMINAL FLOOR
EXST.
EXP.
EXISTING
EXPANSION
MULL.
MULLION
U.O.N.
U.P.S.
UNLESS OTHERWISE NOTED
UNINTERUPTED POWER
ikelockersand
cks: Federal W f' S. ..
+1'-0" ELEVATION
HEIGHTABOVE/BELOW
DETAIL REFERENCE SYMBOL ( )
EXT.
EXTERIOR
N.
N.I.C.
NEW
NOT IN CONTRACT
UNF.
SUPPLY
UNFINISHED
Washington
Conference ofSeventh...v
BUILDING SPACE / ROOM ID
F.B.
FLAT BAR
N.T.S.
NOT TO SCALE
UR.
URINAL
DTL
F.D.
FLOOR DRAIN
NO.
NUMBER
OFFICE SPACE NAME
SHT
F.E.
FIRE EXTINGUISHER
NOM.
NOMINAL
V.B.
VAPOR BARRIER
S323rd St S323rdst n
DaVita C orporate office 0
Q
1127 SPACE NUMBER
F.E.C.
FIRE EXTINGUISHER
CABINET
N/A
NOT APPLICABLE
V.C.A.
V.G.
VINYL COMPOSITION TILE
VERTICAL GRAIN
F.F.
FACTORY FINISH
O.C.
OVERALL
V.I.F.
VERIFY IN FIELD
COLUMN AND/OR GRID LINE SYMBOL
DIMENSION LINE: x
F.F.E.
FINISH FLOOR ELEVATION
O.C.
ON CENTER
V.W.C.
VINYL WALL COVERING
r
- DOOR NUMBER
F.F.W.
FINISH FACE OF WALL
O.H.
OVERHEAD
VERT.
VERTICAL
x
F.I.O.
FURNISHED AND INSTALLED
O.L.
OCCUPANT LOAD
VEST.
VESTIBULE
NORTH
BY OWNER
O.S.B.
ORIENTED STRANDBOARD
20' - 0"ie DOCUMENT SHEET SYMBOL
F.O.
FACE OF
0/
OVER
W.
WIDE
F.O.F.
FACE OF FINISH
OBS.
OBSCURE
W.A.
WATER CLOSET
O 0 KEYED SHEET NOTES
F.O.I.C.
FURNISHED BY OWNER,
OCC.
OCCUPANT
W.H.
WATER HEATER
INSTALLED BY
OFF.
OFFICE
W.P.
WATERPROOF
KEY PLAN / FLOOR PLATE
G1 � GLAZING SYMBOL
O
CONTRACTOR OP. OPERABLE W.R. WATER RESISTANT
F.T.I.C. FURNISHED BY TENANT, OPNG. OPENING W/ WITH
_
/ 32" -
SCALE: 1 V-0"
L ANGLE
INSTALLED BY
OPP.
OPPOSITE
W/O
WITHOUT
AT Q�
CONTRACTOR
OVHD.
OVERHEAD
WD.
WOOD
REVISION NUMBER
F.U.
FIREPROOF
WDW.
WINDOW
CENTERLINE
WT.
WEIGHT
CPT1 FINISH SYMBOL
DEFINITIONS AND DIMENSIONS
A. DEFINITIONS:
1. "TYPICAL" OR "TYP" INDICATES IDENTICAL COMPLETE SYSTEM FOR THE CONDITION NOTED.
2. "SIMILAR" OR "SIM." INDICATES COMPLETE SYSTEM AND COMPONENTS COMPARABLE TO THE CHARACTERISTICS FOR THE CONDITION NOTED.
O O O
O
3. "AS REQUIRED" INDICATES CONTRACTOR SHALL PROVIDE COMPONENTS REQUIRED TO COMPLETE THE NOTED SYSTEM AS INDICATED IN
THE PROJECT DOCUMENTS.
4. "ALIGN" INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT, TRUE, AND PLUMB RELATION ADJACENT MATERIALS.
r------�
5. "CLEAR" INDICATES CRITICAL DIMENSION AND SHALL SET PRECEDENT FOR LAYOUT OF PARTITIONS.
t
"`
B. DIMENSIONS:
t
AREA OFF rp
1. DIMENSIONS ARE INDICATED TO THE FACE OF FINISHED SURFACE AT ALL NEW AND EXISTING CONSTRUCTION, CENTER OF COLUMNS OR GRID LINES UNLESS OTHERWISE NOTED.
WORK
t
t t
2. ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE &PLUMB. DIMENSIONAL LAYOUT SHALL
BE IN THE FOLLOWING PRIORITY ORDER.
A. STRUCTURAL DRAWINGS
t O i13VO
O
B. LARGE SCALE DETAILS
t
tF97M
C. SMALL SCALE DETAILS
t t
D. ENLARGED PLANS AND SECTIONS
E. FLOOR PLANS0
i t
t t
t
z
3. MINIMUM DIMENSIONS FOR ACCESSIBILITY CLEARANCES AND BUILDING CODE REQUIREMENTS SHALL BE MAINTAINED.
t
O
4. FLOOR ELEVATIONS ARE INDICATED AT THE FACE OF THE STRUCTURAL SLAB, UNLESS OTHERWISE NOTED.
---------------------�
5. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED MATERIAL, UNLESS NOTED ABOVE FINISH FLOOR
- "AFF".
6. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED ACOUSTIC CEILING GRID OR FACE OF FINISH MATERIAL FOR OTHER CEILING TYPES, UNLESS OTHERWISE NOTED.
7. DOCUMENTS ARE DRAWN DIAGRAMMATICALLY, AND SCALED DIMENSIONS ARE APPROXIMATE. DIMENSIONS SHALL INDICATE REQUIRED SIZE, CLEARANCES, AND RELATIONSHIPS ARE INDICATED BY DIMENSIONS AS NOTED.
BURGESS DESIGN
I N T E R I O R S A R C HI T E C T U R E
1326 Sth Ave Suite 400 Seattle WA 1 206.587.7120
Tenant Improvement For:
STERLING REALTY
777108TH AVE. NE, SUITE 2150
BELLEVUE, WA 98004
RECEIVED
Feb 15 2022
Tenant:
BERRY-'C I U q
A_ WAY
ELOPMENT
32001 32ND AVE. S., SUITE 340
FEDERAL WAY, WA 98001
CONSTRUCTION WORK SHALL NOT PROCEED UNTIL THE BUILDING
OWNER / REPRESENTATIVE AND BUILDING TENANT HAVE GIVEN THEIR
APPROVAL TO THESE CONSTRUCTION DOCUMENTS. APPROVAL BY
THESE PARTIES SHALL BE INTERPRETED AS APPROVAL OF DRAWINGS
FOR CONTENT, FINISH SELECTIONS, SCOPE OF WORK, AND ALL
DIMENSIONS REGARDED BY EITHER PARTY AS BEING NECESSARY TO
THEIR OPERATIONS, USE OF THE SPACE, FURNISHINGS, AND TENANT
EQUIPMENT AND FURNITURE INSTALLATIONS.
CONSTRUCTION AND/OR INITIATION OF CONSTRUCTION, AUTHORIZED
BY THE BUILDING OWNER FROM THESE CONSTRUCTION DOCUMENTS,
SHALL BE INTERPRETED BY THE DESIGNER AS APPROVAL IN FULL OF
THESE CONSTRUCTION DOCUMENTS BY BOTH THE BUILDING OWNER I
REPRESENTATIVE AND THE TENANT.
Professional seal
6709
REGISTERED
ARCHITECT
BRADLE ROBERT SMITH
STATE F WASHINGTON
No. Issue Description Date
REVIEW SET 2.2.22
PERMIT SET 2.9.22
CLIENT APPROVAL DATE
City Electronic Stamp Location
Drawn by: XX AK Project Manager: MA
Project No: 22.0103.00
COVER SHEET/
PROJECT INFORMATION
z
;v
r
a Original drawing is 24" x 36". Scale entities accordingly if reduced
G1001
0
0
a