Loading...
21-100278h Building - Single Family City or Federal Way Permit #:21-100278-00-SF Community Development Dept. 33325 8th Ave S Federal Way, WA 98003 Inspection Request Line: (253) 835-3050 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name: TERRAMAX Project Address: 30334 30TH AVE SW Parcel Number: 416660 0474 Project Description: BLUEBEAM - Construction of a new 3349 square foot 2-story single family residence with a 28 square_foot covered entry and a 576 square foot attached garage. Includes plumbing and mechanical. ***3 Bedrooms; $720000 Estimated Selling Price*** Owner Applicant Contractor Lender MAXIM AFICIUCTERRAMAX ADAM DOUBASSFK TERRAMAX GENERAL PYATT BROADMARK GENERAL CONTRACTING LLC, CONSULTING CONTRACTING LLC 1420 5TH AVE SUITE 2000 10602 41ST ST E 2100 S 260TH ST 10602 41ST ST E SEATTLE WA 98101 EDGEWOOD WA 98372 DES MOINES WA 98198 EDGEWOOD WA 98372 Census Category: 101 - New Single Family House Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) 1 3,349.00 Additional Permit Information New / Additional Sq. Feet - I st Floor ..................... 1600 New / Additional Sq. Feet - 2nd Floor..........,......... 1749 New / Additional Sq. Feet - 3rd Floor ................... 0 Occupancy # I -Area (Sq. Feet) .............................. 3349 New / Additional Sq. Feet - Basement .................... 0 Basic Plan?........................................................... No Occupancy #1 - Construction Type ......................... Type V - B New / Additional Sq. Feet - Deck ........................... 0 New / Additional Sq. Feet - Garage ........................ 576 Mechanical to be Included? ................ ................ •.... Yes Plumbing Work Valuation? ..................................... 15000 Mechanical Work Valuation?.................................. 10000 Number of Stories ................................................... 2 New / Additional Sq. Feet - Other........................... 28 Plumbing to be Included? ........................................ Yes New / Additional Sq. Feet - Total........................... 3953 Will Certificate of Occupancy be Issued? ............... Yes Occupancy #1 - Use............................................... Residence (1 or 2 family) Comprehensive Plan Designation ....................... SF - High -Density Zoning Designation ............................................... RS 7.2 Residential Total Valuation: 442,851.96 Air Handling Units Ducting Furnaces Bathtubs Laundry Washer Outlets Sinks Hose Bibbs Mechanical Fixtures 1 Air Conditioners - Stand Alon( 1 Fans 1 Gas Piping Plumbing Fixtures 2 Dishwashers 1 Lavatories 2 Water Closets I 1 Compressors / Heat Pumps 1 9 Fireplace Inserts 1 1 Gas Pipe Outlets 5 1 Drains 3 4 Showers 2 2 Water Heaters 1 CONDITIONS: The following conditions are from CD Planning as conditions of the UP3 Reasonable Use approval file 18-101254 UP 4) Prior to, and for the duration of, construction activity, the applicant shall install protective silt fencing and orange construction fencing along the outer boundary of the established building area. This fencing shall be maintained serviceable throughout the construction of the proposed single-family homesite. A preconstruction inspection by the Planning Division is required to verify the fencing has been installed. Contact Senior Planner Stacey Welsh at 253-835-2634 to schedule the inspection. 5) Prior to issuance of a Certificate of Occupancy, a split rail fence shall be placed along the defined outer buffer boundary adjacent to the new homesite with critical areas signage installed every 150 feet. Contact Public Works Development Services for the sign detail. A final inspection by the Planning Division is required to verify the split rail fence and signage has been installed. Contact Senior Planner Stacey Welsh at 253-835-2634 to schedule the inspection. 7) In accordance with the October 10, 2018, Wetland and Stream Buffer Establishment and Enhancement Program prepared by Habitat Technologies, prior to issuance of a Certificate of Occupancy, the on -site stream and wetland retained buffer areas shall be initially cleared of the existing garbage, yard and construction waste, and invasive vegetation. Beneficial native trees and shrubs shall be identified and flagged by the project biologist and shall not be removed. The removal of the invasive shrubs and assorted debris shall not adversely impact the soil profile or offsite aquatic features. 8) In accordance with the October 10, 2018, Wetland and Stream Buffer Establishment and Enhancement Program prepared by Habitat Technologies, prior to issuance of a Certificate of Occupancy, the established buffer area along the eastern portion of the project site shall be planted with a variety of native trees and shrubs common to the local area. These activities shall create a plant community that protects and enhances the function and value of stream and wetland buffers, provides wildlife habitat, and protects local water quality. 9) In accordance with the October 10, 2018, Wetland and Stream Buffer Establishment and Enhancement Program prepared by Habitat Technologies, all onsite enhancement activities shall be monitored by the project biologist. Final plant placements shall be approved by the project biologist prior to installation. Following the completion of onsite planting activities an implementation report shall be prepared and submitted to the city. The implementation report shall be provided to the city prior to issuance of a Certificate of Occupancy. 10) In accordance with the October 10, 2018, Wetland and Stream Buffer Establishment and Enhancement Program prepared by Habitat Technologies, upon the city's acceptance of the implementation report a five-year monitoring program shall be undertaken following the successful completion of the initial planting efforts to ensure the success of the buffer enhancement 1)ro2ram. PERMIT EXPIRES Monday, 28 March, 2022 Permit Issued on Wednesday, September 29, 2021 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of W1 it(I-a-od the City of Federal Way. Owner or agent 19 Date: City of Federal Way Certificate of occupancy This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: TERRAMAX Address: 30334 30TH AVE SW Includes: # 1 #2 #3 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) 3,349.00 Owner Name: MAXIM AFICIUCTERRAMAX GENE] Owner Address: 10602 41ST ST E EDGEWOOD WA 98372 Permit # 21-100278-00-SF #4 �1y�Z3 Date The priority focus inf he review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises. I i4� CITY OF Federal Way THIS CARD IS TO REMAIN ON -SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 21 100278 00 Address: 30334 30TH AVE SW Project: MAXIM AFICIUC FEDERAL WAY WA 98023 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. 0 SWM Precon Site Mtg (4400) FI] Initial Erosion Control (4365) El Footings/Setback (4110) Approved To be done PRIOR to breaking ground Approved to place concrete By Date By Date By Date ® Foundation Wall (4115) Q Drainage/Downspout (4040) © Plumbing Groundwork (4190) Approved to place concrete Approved to backfill Approved to cover By Date By Date By Date 0 Slab/Concrete Floor (4255) ® Underfloor Framing (4285) ® Floor Sheathing (4105) Approved to place concrete Approved to sheath floor Approved to install flooring By Date By Date By Date 117 Shear Walls (4245) 11 Roof Sheathing (4220) 1Z Rough Plumbing (4230) Approved to install siding Approved to install roofing Approved By Date By Date By Date 13 Mechanical Rough -in (4165) 14 Gas Piping (4125) 15 Fire/Draft Stops (4095) By Approved Date Approved to release test By Date By Approved �� Date 3I 16 Interim Erosion Control (4370) Approved Prior to scheduling a Framing inspection; Electrical, Plumbing & Mechanical Rough -in and Fire/Draft Stop inspections must be signed - 17 Framing (4120) Approved to insulate By Date off and approved. IBC 109.3.4 By Date 3 q Z its Insulation (4150) 19 Gypsum Wallboard Nailing (4130) 2U Final - Planning (4070) Approved to instal wallboard Approved to install mud & tape Approved Bydf� Dateql�'112 By Date 4t3 By Date f 21 Final Erosion Control (4375) z2 Final - Mechanical (4065) 23 Final - Plumbing (4075) Approved Approved Approved By Date 1111q 1-1'� 111 [ By Date By Date LZ 24 Final -Building (4050) A c ant v,� 1 i! V1 Approved NIJ• trl� Q� + lt t��l � By C2 Date Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date `OF Federal Way Building Division 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: _ PERMIT#:'d/-Zno 7 LSL IF YOU HAVE QUESTIONS CALL 4,dt (253) 835-.� WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. 3.21 2Z m DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of CITY OF V:�k� Federal Way ADDRESS: • Building Division 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE PERMIT#: ■rl , tea/ I•J V IF YOU HAVE QUESTIONS CALL (253) 835- 7G 3 1 _ WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835_3L FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. 1?1 (_c 1 Z ___k+j DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of ACASCA�E� 1 800 366-6495 Rosboro X-Beam: Widths. 3.5'; 5.5'; 6.75 8.75" Depths: Std. GLB Design Properties Fb Tension 2400 psi Fb Compression 1850 psi Fv Horizontal Shear 265 MOE 1.8 X 106 (Shear Modulus of Elasticity) Rosboro Big Beam DF: Widths: 3.5'; 5.511 7" Depths: 1-joist sized Design Properties Fb Tension 3000 psi Fb Compression 3000 psi Fv Horizontal Shear 265 MOE 2.1 X 106 (Shear Modulus of Elasticity) Parailam Beam: Widths: 3.5'; 5.25". 7"Depths: Ijoistsized Design _Properties Fb Tension 2900 psi Fb Compression 2900 psi Fv Horizontal Shear 290 MOE 2.0 X 106 (Shear Modulus of Elasticity) Versa -Lam: Widths: 3.5'; 5.25", 7"Depths: 1-joist sized ❑esi n Properties Fb Tension 3100 psi Fb Compression 3000 psi Fv Horizontal Shear 285 MOE 2.0 X 106 (Shear Modulus of Elasticity) NC -Lam PWLVL: Widths: 3.5'; 5.25. 7"Depths: I joist sized Design Properties Fb Tension 3100 psi Fb Compression 3000 psi Fv Horizontal Shear 285 MOE 2.0 X 106 (Shear Modulus of Elasticity) F'1r KIL RJN & ASSOCIATES Project: [,rr `kxx fLI-) 1220 South 356th Street. suite A-3 Shee t:, 7C Job #: Federal Way, WA 980038 / (253) 874-9323 Fax (253)874-9323 Calculated by: �%� Dote: -31?XL — Checked by: Date: D". /da r"J,A-1 63 S 247) u