22-103296Electrical
City nityDe Federal
Development
'""' Permit #:22-103296-00-EL
Community Development Dept.
33325 8th Ave S'
Federal Way, WA 98003 +A 1LE Inspection Request Line: (253) 835-3050
Ph: (253) 83&2607 Fax (253) 835-2609
Project Name: WESTSIDE CENTER BLDG B
Project Address: 33305 1ST WAY S Parcel Number: 926500 0230
Project Description: DISCONNECT AND RECONNECT WITH NEW (1) ROOFTOP HVAC UNIT (1) EXISTING
480 VOLT, 3 PHASE, 150 AMP CIRCUIT
Owner
Applicant
Contractor
STOCK FAMILY LLC
AMMONE BEMBRYMACDONALD
MACDONALD MILLER FAC SOL INC
909 S 336TH ST SUITE 103
MILLER FAC SOL INC (ELECTRICAL)
(ELECTRICAL)
FEDERAL WAY WA 98003
7717 DETROIT AVE SW
MACDOMF972BF (1/6/23
SEATTLE WA 98198
7717 DETROIT AVE SW
SEATTLE WA 98106
Additional Permit Information
Is this an Online or O.T.C. application? .................. Yes
Electrical Fixtures
Circuits - Commercial 1
PERMIT EXPIRES Wednesday, 18 January, 2023
Permit Issued on Friday, July 22, 2022
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
Washin ton and the City of Federal Way.
N N
Owner or agent: Date:
r.-1 AA)
As�
CITY OF
Federal Way
THIS CARD IS TO REMAIN ON -SITE
Construction Inspection Record
INSPECTION REQUESTS: (253) 835-3050
PERMIT #: 22 103296 00 Address:
33305 1ST WAY S Bldg B
Project: STOCK FAMILY LLC
FEDERAL WAY WA 98003
Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you
are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card.
0
UFER Ground (4295)
0 Ditch cover (4030)
0 Slab/Concrete Floor (4255)
Approved
Approved
Approved to place concrete
By
Date
By Date
By Date
® Pool Bonding (4195)
Q Temporary Power (4275)
Q Service (4235)
Approved
Approved
Approved
By
Date
By Date
By Date
L]
Feeders/Sub-panels (4045) 0 Rough Electrical (4225)
® Ceiling Cover (4020)
Approved Approved
Approved
By
Date By Date
By Date
0
Final - Electrical (4055)
By
%�Approved
Date
Rough Electrical
Final Electrical
Right of Way
Approved
Approved
Approved
By
Date
By
Date
By
Date
CITY OF Building Division
33325 Eighth Avenue South -
Federal WayFederal Way, 98003-6325 Phone 253-835-2607 Faxx 253-83535-2609609
CORRECTION NOTICE
ADDRESS: I f� PERMIT#:
IF YOU HAVE QUESTIONS CALL
- ,11 dpr _
(253) 835-
WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD
FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS.
DATE
INSPECTOR
DO NOT REMOVE THIS NOTICE
Page of