Loading...
07-103419C17 Federal Way September 26, 2007 Realcom Associates 14432 Eastgate Street, Suite 260 Bellevue, WA 98007 CITY HALL 33325 8th Avenue South Mailing Address: PO Box 9718 Federal Way, WA 98063-9718 (253) 835-7000 www.cityoffederalway.com RE: File #07-103419-00-UP; USE PROCESS III APPROVAL AT&T @ Buena (WA931), 31001 8'h Avenue South, Federal Way Dear Ms. Johnson: The City has completed a land use "Process III" Administrative Review of your proposal to collocate wireless antennas on an existing water tank. The proposal also includes associated transmission equipment that will be located in a new CMU shed. As a part of this proposal, a CMU block shed will be constructed to conceal the transmission equipment. This CMU block shed will be consistent with other buildings which currently exist on site. The proposal includes the installation of two antennas per sector (three sectors total). The proposed antennas are 6'6", which will be painted to match that of the water tank and will be visually screened by the mature natural vegetation surrounding the subject parcel. Pursuant to Federal Way City Code (FWCC) Chapter 22, Article VI, "Process III — Project Approval," your proposal is found to be consistent with the provisions of Chapter 22, "Zoning." Your Process III proposal is hereby conditionally approved. CONDITIONS An electrical permit is required by the City's Building Division prior to commencing any construction. 2. A building permit is required by the City's Building Division prior to the construction of equipment enclosure building. To assure compliance with the approved final plans, the applicant shall also contact the Planning Division of the Department of Community Development Services for a final inspection of the PWSF. At that time, the applicant shall submit an affidavit to the Planning Division that verifies that the PWSF has been installed in accordance with the approved plans. 4. If on review of a registered complaint the city finds that the PWSF interferes with the reception of television or radio broadcasts, the city may revoke or modify the permit pursuant to FWCC 22-972. The applicant shall be given a reasonable time based on the nature of the problem to correct the interference. If the permit is revoked, then the facility shall be removed. r :1^ Ms. Johnson September 26, 2007 Page 2 PWSF COMPLIANCE In accordance with FWCC Section 22-972, preceding the issuance of an operation permit, a six-month EMF report shall be submitted to the City outlining cumulative field measurements of radio frequency power densities of all antennas installed at the subject site. Furthermore, five years from the date of this Process III approval, the City shall receive from the applicant a statement summarizing its current use and plans for the facility for the next five years. Pursuant to FWCC Section 22-974, a permit for a PWSF shall expire ten years after the effective date of the permit approval. Renewals will be considered. CLOSING This decision shall not waive compliance with future City of Federal Way codes, policies, and standards relating to this site. Final construction drawings will be reviewed for compliance with specific regulations and other applicable City requirements. This Process III approval does not constitute approval of an electrical permit. The effective date of this decision is October 1, 2007. Pursuant to FWCC Section 22-355, any person who received notice of the administrative decision may appeal this decision to the Federal Way Hearing Examiner by October 15, 2007. Generally, no work on the proposal may commence until the end of the appeal period. For this project you are the only party receiving notice. You may waive your right to an appeal by letter, or you may simply wait for the appeal period to end. If a building or electrical permit is required, you may not commence work until you have been issued the appropriate permit(s). This Process III approval is valid for one year from the effective date of this decision. If no further action is taken within one year, this decision will expire. A one-time, six-month extension may be granted only if a written request is submitted to the City's Department of Community Development Services (33325 81' Avenue South, PO Box 9718, Federal Way, WA, 98063-9718) at least 30 days prior to the expiration of the decision. If you have any questions, please contact Associate Planner Matt Herrera at 253-835-2638, or matt.herrera@cityoffederalway.com. Sincerely, A-� fc-, Greg Fewins Interim Director of Community Development enc: Approved Plans Facts & Findings C Matt Herrera, Associate Planner Ann Dower, Public Works 07-103419 Doc. I D. 42472 Fll. E CITY OF 4A Federal Way FINDINGS FOR PROJECT APPROVAL AT&T @ Buena (WA 937) File #07-103419-UP 31001 8`' Avenue South Zoning, Land Use, and Review Process — The zoning for the proposed site is Single -Family Residential (RS 7.2). PWSFs are permitted in the RS zone pursuant to the zoning chart found in FWCC Section 22-649. For this particular proposal, the required land use review is Process III. 2. State Environmental Policy Act (SEPA) — A Determination of Nonsignificance (DNS) was issued on August 31, 2007. 3. PWSF Prioritized Locations (FWCC Section 22-966[d]) —The proposal falls into Priority #2. The proposed PWSF is to be located on an existing publicly used (water tank) structure that is owned by Lakehaven Utility District. 4. PWSF Development Standards (Located on structures within appropriate rights -of -way, FWCC Section 22-967[3]) — The proposed PWSF is to be located in a publicly used structure (Lakehaven Utility District owned; existing water tank) on 30929 8`h Avenue South. 5. PWSF Height Standards (FWCC Section 22-967(2)(a)(2(iv)(b)) —The proposed PWSF exceeds the minor facility thresholds for dimensions and/or area, but creates no more adverse impacts than minor facilities. The proposed PWSF meets all of the required standards set forth in FWCC 22-967 (1)(2)(i-iv). Standards for Electronic Equipment Enclosures (FWCC Section 22-967[5]) —The equipment cannot be placed underground as there are currently numerous underground utilities (including waterlines, and power). It is the application's position, as agreed by the property owner (Lakehaven Utility District) that it would be best if the equipment remained above ground so as not to interfere with future water lines. Additionally, the placement of equipment below grade would disrupt the existing mature vegetation screening the entire compound from adjacent properties. 7. Standards for Equipment Enclosure Size (FWCC Section 22-967[3]) — AT&T will use an above ground equipment CMU building and has proposed to locate the equipment cabinet as far away as possible from the adjacent residential structures. The proposed CMU block building will match that of the existing structures on site; and therefore will be in keeping with current development on the property. The equipment CMU building is proposed to be completely enclosed and architecturally designed as stated in FWCC 22-967(5)(d). 8. Cumulative Effects (FWCC Section 22-967[8]) — The City must consider the cumulative visual effects of PWSFs mounted on existing structures and/or located on a given permitted site in determining whether additional permits may be granted, so as to not adversely affect the visual character of the City. The applicant has submitted photo -simulations of the proposed PWSF. As shown in the plans and the photo -simulations, the proposed PWSF will not adversely affect the visual character of the City. The applicant has proposed to paint the antennas to match that of the existing water tank to further ensure that the PWSF will not adversely affect the visual character of the City. 9. Collocation (FWCC Section 22-971) — The code requires a signed statement indicating that the applicant agrees to allow for the potential collocation of additional PWSF equipment by other providers on the applicant's structure, or within the same site location, as part of the permit application. This does not apply to the proposal, since the existing structure is owned by an entity other than the applicant. 10. EMF Standards and Interference (FWCC Section 22-972) — Within six months after the issuance of its operation permit, the applicant shall submit a project implementation report which provides cumulative field measurements of radio frequency (ENT) power densities of all antennas installed at the subject site. Also, the applicant has ensured and has been conditionally approved this land use permit that if any interference is experienced by television or radio broadcast facilities, the applicant shall mitigate the interference before the AT&T site becomes commercially available. 11. Permit Limitations (FWCC Section 22-974) — A permit for a PWSF shall expire ten years after the effective date of the permit approval. Renewals will be considered. Also, "...five years after the effective date of the land use process approval of a PWSF, the permittee or assignee shall submit a written statement summarizing its current use and plans, if any, for that facility/site for the next five years to the best of their knowledge." Findings for Project Approval Page 2 AT&T @ Buena (WA 937) File #07-103419-UP/noa. 1.D.42493 FILE CITY OF ti. Federal Way July 29, 2008 Realcom Associates 14432 Eastgate Street, Suite 260 Bellevue, WA 98007 CITY HALL 33325 8th Avenue South Mailing Address: PO Box 9718 Federal Way, WA 98063-9718 (253) 835-7000 www cityoffederalway. com RE: File #07-103419-00-UP; REQUEST FOR REQUIRED EMF REPORT AT&T @ Buena (WA931), 31001 8`h Avenue South, Federal Way To Whom It May Concern: The City of Federal Way's Department of Community Development Services issued land use approval for the above -referenced application on October 10, 2007. Pursuant to Federal Way City Code (FWCC) Section 22-972, within six months of receiving land use approval the applicant is responsible for submitting a project implementation report that provides cumulative field measurements of radio frequency (EMF) power densities of all antennas installed at the subject site. At this time, the City has not received the required EMF report for the above -referenced project. Please submit this report within 60 days of receipt of this letter. The report must quantify the EMF emissions, compare the results with established federal standards, and provide a statement that the EMF emissions are within established federal standards. Said report shall be subject to review and approval by the City for consistency with the project proposal and the adopted federal standards. If you have any questions regarding this letter, please feel free to call me at 253-83 5-264 1. Sincerely, `RI Rebecca Chapin Planning Intern Doc I D. 46098 R E C 0 M October 4, 2007 Cily of Federal Way Department of Community Development 33325 Eighth Avenue South Federal Way, WA 98063 Re: Proposed Cingular Wireless Site at Federal Way - Buena (WA-931) Land Use Application File # 07-103419-00 UP Mattliew, AT&T has received a copy of the decision in regards to the aforementioned land use application, and waives the appeal on this decision. Sincerely, ASSOCATES, LLC, rcprescnthjgAT&-TfI-a Cingulu- Wreless 14432 Eastgate Way SE, Suite 260 • Bellevue, WA 98007 p 425-274-4444 0 f 425-274-4449 WA7FW -vr Rad�� 2007-2008 OFFICERS & TRUSTEES PRESIDENT STEVE HATCH, WA7DAD VICE-PRESIDENT DANIEL STEVENS, KL7WM SECRETARY Jot-I:a HoLMQuIsr, W7WAY TREASURER MIKE McCoy, N7VWD PAST PRESIDENT GARY BRYAN, KG7KU TRUSTEES STEVE HATCH, WA7DAD DANIEL STEVENS, KL7WM JOHN HoLMQU1ST, W7WAY MncE McCoy, N7VWD DA, � CA v, KK7UZ GREG BEECK, KD711Q GARY BRYAN, KG7KU Federal Way Amateur Radio Club A non profit Washington Corporation -federal ID 91-1935165 October 4, 2007 Matthew Herrera City of Federal Way Department of Community Development 33325 Eighth Avenue South Federal Way, WA 98063 Re: Proposed Cingular Wireless Site at Federal Way - Buena (WA-931) Land Use Application File # 07-103419-00 UP Matthew, The FWARC has received a copy of the letter (September Ie) from AT&T where Kevin Chu, Director of Pacific Northwest RF Engineering for AT&T commits to mitigate any and all interference to our equipment resulting from their proposed installation. FWARC has also received a copy of the decision by the city in regards to the aforementioned land use application, and waives the appeal on this decision. —Sincerely; 4 � David Swartz Repeater Operations Federal Way Amateur Radio Club Post Office Sox 23415 Federal Way, Wasiiingtan 98093 Email: wa7fw@fwarc.org Internet: www.fwarc.org T``�t ` AT&T Mobility T: 425.580.8763 P.O. Box 97061 F: 425.580.9976 Redmond, WA 98073-9761 www.att.com September 18, 2007 David Swartz Repeater Operations, Federal Way Amateur Radio Club P.O. Box 23415 Federal Way, WA 98093 Re: WA931--Federal Way Buena site Dear Mr. Swartz, The following is in response to your concern that AT&T's proposed site located at 30929 8th Ave South, Federal Way, WA 98003, may cause intermodulation interference to the Federal Way Amateur Radio Club's radio repeater at that location. While a study shows potential third order intermodulation products landing on your repeater's channel, a computer study is not a guarantee of interference. The robust nature of your radio equipment and ours makes intermod being generating your equipment or our equipment unlikely. However, other sources for signal -mixing may exist in the environment and cannot be ruled out as a potential interference source. AT&T could retune our network to create a channel set for this site that is free of theoretical third order intermod products. However, retuning is something we do to improve our overall network, not just a single site. I propose we tackle the situation as follows. Before the AT&T site goes into commercial service, let's perform an on/off test to determine if any interference is experienced by your facilities. If there is any interference, we will mitigate the interference before the AT&T site becomes commercially available. Further, should the Federal Way Amateur Radio Club determine that your equipment is suffering from any interference after the AT&T site becomes commercially available, please contact me directly. I will dispatch an engineer to work with you and your personnel to troubleshoot and mitigate the interference as quickly as possible. I will submit a copy of this letter into the record for the land use review for the City of Federal Way. If I can be of further assistance in this matter please do not hesitate to contact me. Sincerely, Kevin Chu Director, Pacific Northwest RF Engineering L&A Pmud sgoosor of the U.S. olyniPic Team f� Intermodulation Program Company: Federal Way Amateur Radio Club Engineer: David Swartz Z `f • 6 Z`� Site Name: Lakehaven Site Description: Tanks 1 and 4 Date: Monday, August 27, 2007 Minimum Separation: 25.0 KHz zkove , Swartom@ cvw'. Transmission Frequencies: 01,933.40000 MHz 01,934.40000 MHz ?ebp. 01,935.00000 MHz > P�i �. d 00,147.04000 MHz f =eo�r-% D /u 00,442.95000 MHz 00,869.80000 MHz os�d t-7 # r e4 00,870.40000 MHz P /r�'^srz.�� �teyuenci 00,871.00000 MHz lS/•S%5—M/� Le�����-, Gs�lf Sfn`Uf Receiver Frequencies: 01,853.40000 MHz 01,854.40000 MHz 01,855.00000 MHz 00,147.64000 MHz -;� �-V,i/xf tj—/ 00,447.95000 MHz 00,824.80000 MHz 00,825.40000 MHz 00,826.00000 MHz A+B-C: 1,935.00000 + 147.04000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B-C: 147.04000 + 1,935.00000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B-C: 147.04000 + 870.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B-C: 147.04000 + 871.00000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B-C: 870.40000 + 147.04000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B-C: 871.00000 + 147.04000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz 1. v� �-r-w��lc{'iu4 rJ�{vGt Jw@7 15 vvL re c.e t vex RECEIVED AUG 2 S 2007 CITY OF FEDERAL WAY BUILDING DEPT, Intermodulation Program Company: Federal Way Amateur Radio Club Engineer: David Swartz Site Name: Lakehaven Site Description: Tanks 1 and 4 Date: Monday, August 27, 2007 Minimum Separation: 25.0 KHz Transmission Frequencies: 01,933.40000 MHz 01,934.40000 MHz 01,935.00000 MHz 00,147.04000 MHz 00,442.95000 MHz 00,869.80000 MHz 00,870.40000 MHz 00,871.00000 MHz Receiver Frequencies: 01,853.40000 MHz 01,854.40000 MHz 01,855.00000 MHz 00,147.64000 MHz 00,447.95000 MHz 00,824.80000 MHz 00,825.40000 MHz 00,826.00000 MHz A+B+C-D-E: 1,933.40000 + 1,935.00000 + 147.04000 - 1,933.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,933.40000 + 1,935.00000 + 147.04000 - 1,934.40000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,933.40000 + 147.04000 + 1,935.00000 - 1,933.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,933.40000 + 147.04000 + 1,935.00000 - 1,934.40000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,933.40000 + 147.04000 + 870.40000 - 1,933.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,933.40000 + 147.04000 + 870.40000 - 869.80000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,933.40000 + 147.04000 + 871.00000 - 1,933.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,933.40000 + 147.04000 + 871.00000 - 870.40000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,933.40000 + 870.40000 + 147.04000 - 1,933.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,933.40000 + 870.40000 + 147.04000 - 869.80000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,933.40000 + 871.00000 + 147.04000 - 1,933.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,933.40000 + 871.00000 + 147.04000 - 870.40000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,934.40000 + 1,935.00000 + 147.04000 - 1,934.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,934.40000 + 147.04000 + 1,935.00000 - 1,934.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,934.40000 + 147.04000 + 870.40000 - 1,934.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,934.40000 + 147.04000 + 870.40000 - 869.80000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,934.40000 + 147.04000 + 871.00000 - 1,934.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,934.40000 + 147.04000 + 871.00000 - 1,935.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,934.40000 + 147.04000 + 871.00000 - 869.80000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,934.40000 + 147.04000 + 871.00000 - 870.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,934.40000 + 870.40000 + 147.04000 - 1,934.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,934.40000 + 870.40000 + 147.04000 - 869.80000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,934.40000 + 871.00000 + 147.04000 - 1,934.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz Ij A+B+C-D-E: 1,934.40000 + 871.00000 + 147.04000 - 1,935.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,934.40000 + 871.00000 + 147.04000 - 869.80000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,934.40000 + 871.00000 + 147.04000 - 870.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 1,933.40000 + 147.04000 - 1,933.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 1,933.40000 + 147.04000 - 1,934.40000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 1,934.40000 + 147.04000 - 1,934.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 1,935.00000 + 147.04000 - 1,934.40000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 1 U5.00000 + 147.040W- 1,935.00000 - 1,934.400 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + )04000 + 1,933.40000 - 1,933.40000 - 1,934. 0 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 1,933.40000 - 1,934.40000 - 1,933.40u00 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 1,934.40000 - 1,934.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 1,935.00000 - 1,934.40000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 1,935.00000 - 1,935.00000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 147.04000 - 1,934.40000 - 147.04000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 147.04000 - 147.04000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 442.95000 - 1,934.40000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 442.95000 - 442.95000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 869.80000 - 1,934.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 869.80000 - 869.80000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 870.40000 - 1,934.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 870.40000 - 1,935.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 870.40000 - 869.80000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 870.40000 - 870.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 871.00000 - 1,934.40000 - 871.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 871.00000 - 1,935.00000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 871.00000 - 870.40000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 147.04000 + 871.00000 - 871.00000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 442.95000 + 147.04000 - 1,934.40000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 442.95000 + 147.04000 - 442.95000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 869.80000 + 147.04000 - 1,934.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 869.80000 + 147.04000 - 869.80000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 870.40000 + 147.04000 - 1,934.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 870.40000 + 147.04000 - 1,935.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 870.40000 + 147.04000 - 869.80000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 870.40000 + 147.04000 - 870.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 871.00000 + 147.04000 - 1,934.40000 - 871.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 871.00000 + 147.04000 - 1,935.00000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 871.00000 + 147.04000 - 870.40000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 1,935.00000 + 871.00000 + 147.04000 - 871.00000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,933.40000 + 1,935.00000 - 1,933.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz } A+B+C-D-E: 147.04000 + 1,933.40000 + 1,935.00000 - 1,934.40000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,933.40000 + 870.40000 - 1,933.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,933.40000 + 870.40000 - 869.80000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,933.40000 + 871.00000 - 1,933.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,933.40000 + 871.00000 - 870.40000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,934.40000 + 1,935.00000 - 1,934.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,934.40000 + 870.40000 - 1,934.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,934.40000 + 870.40000 - 869.80000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,934.40000 + 871.00000 - 1,934.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,934.40000 + 871.00000 - 1,935.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,934.40000 + 871.00000 - 869.80000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,934.40000 + 871.00000 - 870.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 1,933.40000 - 1,933.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 1,933.40000 - 1,934.40000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 1,934.40000 - 1,934.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 1,935.00000 - 1,934.40000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 1,935.00000 - 1,935.00000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 147.04000 - 1,934.40000 - 147.04000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 147.04000 - 147.04000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 442.95000 - 1,934.40000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 442.95000 - 442.95000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 869.80000 - 1,934.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 869.80000 - 869.80000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 870.40000 - 1,934.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 870.40000 - 1,935.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 870.40000 - 869.80000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 870.40000 - 870.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 871.00000 - 1,934.40000 - 871.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 871.00000 - 1,935.00000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 871.00000 - 870.40000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 1,935.00000 + 871.00000 - 871.00000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 147.04000 + 1,935.00000 - 1,934.40000 - 147.04000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 147.04000 + 1,935.00000 - 147.04000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 147.04000 + 870.40000 - 147.04000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 147.04000 + 870.40000 - 8,69.80000 - 147.04000 = 147.64000 (147.64000), Sep: 00.0 KHz ■ A+B+C-D-E: 147.04000 + 1. �1000 + 871.00000 - 147.04000 - 870.40000 =" 7.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 14 i .04000 + 871.00000 - 870.40000 - 147.04000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 442.95000 + 1,935.00000 - 1,934.40000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 442.95000 + 1,935.00000 - 442.95000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 442.95000 + 870.40000 - 442.95000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 442.95000 + 870.40000 - 869.80000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 442.95000 + 871.00000 - 442.95000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 442.95000 + 871.00000 - 870.40000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 869.80000 + 1,935.00000 - 1,934.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 869.80000 + 1,935.00000 - 869.80000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 869.80000 + 870.40000 - 869.80000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 869.80000 + 871.00000 - 869.80000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 869.80000 + 871.00000 - 870.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 1,933.40000 - 1,933.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 1,933.40000 - 869.80000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 1,934.40000 - 1,934,40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 1,934.40000 - 869.80000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 1,935.00000 - 1,934.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 1,935.00000 - 1,935.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 1,935.00000 - 869.80000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 1,935.00000 - 870.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 147.04000 - 147.04000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 147.04000 - 869.80000 - 147.04000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 442.95000 - 442.95000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 442.95000 - 869.80000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 869.80000 - 869.80000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 870.40000 - 869.80000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 870.40000 - 870.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 871.00000 - 869.80000 - 871.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 871.00000 - 870.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 870.40000 + 871.00000 - 871.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 1,933.40000 - 1,933.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz } A+B+C-D-E: 147.04000 + 871.00000 + 1,933.40000 - 870.40000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 1,934.40000 - 1,934.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 1,934.40000 - 1,935.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 1,934.40000 - 869.80000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 1,934.40000 - 870.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 1,935.00000 - 1,934.40000 - 871.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 1,935.00000 - 1,935.00000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 1,935.00000 - 870.40000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 1,935.00000 - 871.00000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 147.04000 - 147.04000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 147.04000 - 870.40000 - 147.04000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 442.95000 - 442.95000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 442.95000 - 870.40000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 869.80000 - 869.80000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 869.80000 - 870.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 870.40000 - 869.80000 - 871.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 870.40000 - 870.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 870.40000 - 871.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 871.00000 - 870.40000 - 871.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 147.04000 + 871.00000 + 871.00000 - 871.00000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 442.95000 + 1,935.00000 + 147.04000 - 1,934.40000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 442.95000 + 1,935.00000 + 147.04000 - 442.95000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 442.95000 + 147.04000 + 1,935.00000 - 1,934.40000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 442.95000 + 147.04000 + 1,935.00000 - 442.95000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 442.95000 + 147.04000 + 870.40000 - 442.95000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 442.95000 + 147.04000 + 870.40000 - 869.80000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 442.95000 + 147.04000 + 871.00000 - 442.95000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 442.95000 + 147.04000 + 871.00000 - 870.40000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 442.95000 + 870.40000 + 147.04000 - 442.95000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 442.95000 + 870.40000 + 147.04000 - 869.80000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 442.95000 + 871.00000 + 147.04000 - 442.95000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 442.95000 + 871.00000 + 147.04000 - 870.40000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 869.80000 + 1,935.00000 + 147.04000 - 1,934.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 869.80000 + 1,935.00000 + 147.04000 - 869.80000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 869.80000 + 147,04000 + 1,935.00000 :'1,934.40000 - 869.800QO 147.64000 (147.64000), Sep: 00.0 KHz ' 'A+B+C-D-E: 869.80000 + 1 4000 + 1,935.00000 - 869.80000 - 1,934.400 L 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 869.80000 + 147.04000 + 870.40000 - 869.80000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 869.80000 + 147.04000 + 871.00000 - 869.80000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 869.80000 + 147.04000 + 871.00000 - 870.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 869.80000 + 870.40000 + 147.04000 - 869.80000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 869.80000 + 871.00000 + 147.04000 - 869.80000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 869.80000 + 871.00000 + 147.04000 - 870.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 1,933.40000 + 147.04000 - 1,933.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 1,933.40000 + 147.04000 - 869.80000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 1,934.40000 + 147.04000 - 1,934.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 1,934.40000 + 147.04000 - 869.80000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 1,935.00000 + 147.04000 - 1,934.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 1,935.00000 + 147.04000 - 1,935.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 1,935.00000 + 147.04000 - 869.80000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 1,935.00000 + 147.04000 - 870.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 1,933.40000 - 1,933.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 1,933.40000 - 869.80000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 1,934.40000 - 1,934.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 1,934.40000 - 869.80000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 1,935.00000 - 1,934.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 1,935.00000 - 1,935.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 1,935.00000 - 869.80000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 1,935.00000 - 870.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 147.04000 - 147.04000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 147.04000 - 869.80000 - 147.04000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 442.95000 - 442.95000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 442.95000 - 869.80000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 869.80000 - 869.80000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 870.40000 - 869.80000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 870.40000 - 870.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 871.00000 - 869.80000 - 871.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 147.04000 + 871.00000 - 870.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz } A+B+C-D-E: 870.40000 + 147.04000 + 871.00000 - 871.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 442.95000 + 147.04000 - 442.95000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 442.95000 + 147.04000 - 869.80000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 869.80000 + 147.04000 - 869.80000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 870.40000 + 147.04000 - 869.80000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 870.40000 + 147.04000 - 870.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 871.00000 + 147.04000 - 869.80000 - 871.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 871.00000 + 147.04000 - 870.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 870.40000 + 871.00000 + 147.04000 - 871.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 1,933.40000 + 147.04000 - 1,933.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 1,933.40000 + 147.04000 - 870.40000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 1,934.40000 + 147.04000 - 1,934.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 1,934.40000 + 147.04000 - 1,935.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 1,934.40000 + 147.04000 - 869.80000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 1,934.40000 + 147.04000 - 870.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 1,935.00000 + 147.04000 - 1,934.40000 - 871.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 1,935.00000 + 147.04000 - 1,935.00000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 1,935.00000 + 147.04000 - 870.40000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 1,935.00000 + 147.04000 - 871.00000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 1,933.40000 - 1,933.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 1,933.40000 - 870.40000 - 1,933.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 1,934.40000 - 1,934.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 1,934.40000 - 1,935.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 1,934.40000 - 869.80000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 1,934.40000 - 870.40000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 1,935.00000 - 1,934.40000 - 871.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 1,935.00000 - 1,935.00000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz lj A+B+C-D-E: 871.00000 + 147.04000 + 1,935.00000 - 870.40000 - 1,935.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 1,935.00000 - 871.00000 - 1,934.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 147.04000 - 147.04000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 147.04000 - 870.40000 - 147.04000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 442.95000 - 442.95000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 442.95000 - 870.40000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 869.80000 - 869.80000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147 04000 + 869.80000 - 8, 0.40000 - 869.80000 = 1.47.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 1� 'N000 + 870.40000 - 869.80000 - 871.00000 = 7.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 14'i.04000 + 870.40000 - 870.40000 - 870.40000 47.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 870.40000 - 871.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 871.00000 - 870.40000 - 871.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 147.04000 + 871.00000 - 871.00000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 442.95000 + 147.04000 - 442.95000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 442.95000 + 147.04000 - 870.40000 - 442.95000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 869.80000 + 147.04000 - 869.80000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 869.80000 + 147.04000 - 870.40000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 870.40000 + 147.04000 - 869.80000 - 871.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 870.40000 + 147.04000 - 870.40000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 870.40000 + 147.04000 - 871.00000 - 869.80000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 871.00000 + 147.04000 - 870.40000 - 871.00000 = 147.64000 (147.64000), Sep: 00.0 KHz A+B+C-D-E: 871.00000 + 871.00000 + 147.04000 - 871.00000 - 870.40000 = 147.64000 (147.64000), Sep: 00.0 KHz Ij RE L C 0 M qilt No. June 21, 2007 Mr. Andy Bergsagel City of Federal Way Deparhne.nt of Community Development Services 33325 Eighth Avenue South Federal Way, WA 98003 Re: AT&T @ Ranee — Federal Way/Buena (WA931) 31001 Eighth Avenue South, Lakehaven Water Tank Dear Andy, Cingular Wireless is in the process of integrating the existing AT&T Wireless network, with its current network. As part of this, as l,m sure you're aware, there are a significant number of site modifications taking place. In order to help create a seamless network, Cingular Wireless is ready to move forward with the aforementioned site development. Cingular proposes to install up to twelve antennas at the 80, level of the rim of the existing 96" Lakehaven Water Tank, located at the above address_ As part of this proposal a CMU block shed will be constructed to conceal the transmission equipment. This CMU block shed will be consistent with other buildings which currently exist on site_ The existing buildings Douse equipment that supports the water tanks, and are solely for the use of the water district_ The existing vegetation surrounding the property will provide an excellent visual barrier from the surround residential. uses. In fact, with the antennas painted, and the construction completed, few, if any will notice the existence of this facility. At last, here is the full application for this site. We look forward to hopefully being able to complete a quick review, although we would happily look at paying for expedited review. CODE COMPLIANCE: SECTION 966—WIRELESS FACXLE[US (d) Prioritized locations. The following sites shall be the required order of locations for Proposed PWSFs, including antenna and equipment shelters. In proposing a PWSF in a RECEIVED JUN 2 5 2007 CITY OF FEDERAL WAY REALCOM Associates, LLC • 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007 • p 425-2 4- 444 f 425-274-4449 www.realcomassoc.com particular location, the applicant shall analyze the feasibility of locating the proposed PWSF in each of the higher priority locations and document, to the city's satisfaction, why locating the PWSF in each higher priority location and/or zone is not being proposed. In order of preference, the prioritized locations for PWSFs are as follows: (1) Structures located in the BPA trail. A PWSF may be located on any existing support structure currently located in the easement upon which are located U.S. Department of Energy/ Bonneville Power Administration (`BPA") Power Lines regardless of underlying zoning. The BPA easement/transmission power lines are over a mile to the south and do not meet the coverage requirements of this search ring. (2) Existing broadcast, relay and transmission towers. A PWSF may be located on an existing site or tower where a legal wireless telecommunication facility is currently located regardless of underlying zoning. If an existing site or tower is located within a one mile radius of a proposed PWSF location, the applicant shall document why collocation on the existing site or tower is not being proposed, regardless of whether the existing site or tower is located within the jurisdiction of the city. There were no existing towers found within a one mile radius of this site, with the exception of a site to the northwest and a site to the southeast, both of which are currently occupied by the applicant. The original search ring location was actually centered in the residential area to the north of this water tank, and due to a lack of suitable existing structures, it was determined that the location of this water tank would suffice in meeting the coverage objects of this ring. (3) Publicly used structures. If the city consents to such location, a PWSF may be located on existing public facilities within all zoning districts, such as water towers, utility structures, fire stations, bridges, and other public buildings, provided the public facilities are not located within public rights -of -way. As noted in the pre -application review, the applicant is proposing to locate its antennas on an existing publicly used structure, in this case the Lakehaven Water Tank. 22-967—DEVELOPMENT STANDARDS The following development standards shall be followed in the design, siting, and construction of a personal wireless service facility: (1) Building- or structure -mounted PWSFs not located in the public right-of-way. PWSFs mounted on existing buildings and structures not located in a public right-of-way shall conform to the following development standards: a. The PWSF shall consist only of the following types of facilities: 2. A PWSF that exceeds the minor facility thresholds for number of antennas, dimensions, and/or area, but creates no more adverse impacts than a minor facility, as determined by the director of community development services, subject to meeting all of the following standards: i. The facility shall not create substantially more adverse visual impact than a minor facility; and The applicant proposes to paint all antennas to match the water tank to which they are to be attached. The proposed antennas will not exceed the height of the water tank, significantly limiting any perceived visual impact. The proposal, including the location of up to 12 antennas will not cause a greater intrusion, than the location of only three (3) antennas, especially given the mature vegetation surrounding the subject parcel, as well as the height of the existing structure (96' AGL). ii. The equipment cabinet for the PWSF shall meet all requirements of subsection (5) of this section; and The proposed equipment location is as far away as possible from the adjacent residential structures, and is proposed to comply with #2 of the referenced subsection (5) of this section of the FWCC. As the property currently has numerous underground utilities (including water lines, and power), it is the applicants position, as agreed by the property owner/utility district, that it would be best if the equipment remained above ground, so not to interfere with future water lines, should they be necessary. The cost of relocating the proposed CMU structure is much more reasonable. Additionally, the placement of equipment below grade would disrupt the existing mature vegetation screening the entire compound from adjacent properties. Furthermore, the proposed CMU block building will match two of the existing structures on site; and therefore will be in keeping with current development on the property. iii. The maximum size of the PWSF panels and number of antennas shall be determined by the director of community development services, based on the specific project location, surrounding environment, and potential visual impacts; and AT&T Wireless currently controls FCC license which allow for the transmission of three frequencies/technologies. GSM operates on both 850 MHz and 1900 MHz; and UNITS also operatesin the 1900 bandwidth. The proposal includes the immediate installation of two antennas per sector (three sectors total); one antenna will receive and transmit both 1900 MHz frequencies; while the other antenna will handle incoming and outgoing traffic in the 850 MIIz band. The future antennas will be reserved for expansion when network traffic becomes to much for these antennas to share responsibilities. The proposed antenna at this site is 6'6", which is relatively small in terms of the antennas currently deployed by AT&T. Because of the size of the water tank, and the ability to conceal the greater number of antennas, this is the preferred design. Restricting the number of antennas at this location will lead to the necessity of other sites in the surround residential areas, when this site reaches its capacity. iv. The PWSF shall comply with all other applicable standards of the Federal Way City Code. This proposal does comply with the applicable standards as defined by the Federal Way City Code, as determined by the review of this application. b. The combined antennas and supporting structure may extend up to, but not exceed, 15 feet above the existing or proposed roof or other structure regardless of whether the existing structure is in conformance with the existing maximum height of the underlying zone as outlined in the use zone charts, Article M of this chapter, District Regulations. Antennas may be mounted to rooftop appurtenances provided they do not extend beyond 15 feet above the roof proper. The proposed installation will not exceed the height of the existing structure. c. The antennas are mounted on the building or structure such that they are located and designed to minimise visual and aesthetic impacts to surrounding land uses and structures and shall, to the greatest extent practical, blend into the existing environment pursuant to subsection (4) of this section. Panel and parabolic antennas shall be screened from residential views and public rights -of -way unless meeting the provision of FWCC 22-960(b)(2). As previously stated, the proposed design does not increase the height of the water tank, and all antennas will be painted to match said structure. All transmission equipment will be located within a CMU shelter, located at grade. Please see the attached photographs, which show how difficult it is to see this water tank from the neighboring roads. As the one existing CMU building is brick red, and one is more of a sea -foam green, the applicant will work with staff to determine the best color for the proposed enclosure. SECTION 395—Decision Criteria (b) Decisional criteria. The director of community development services shall use the criteria listed in the provision of this chapter describing the requested decision in deciding upon the application. In addition, the director of community development services may approve the application only if- (1) It is consistent with the comprehensive plan; The Federal Way Comprehensive Plan 10.4 specifically addresses telecommunications as part of the necessary utility infrastructure. In addition the following goals and policies from the FWCP relate specifically to this application: PUG 1 Work with private utility companies to allow them to provide full and timely service that meets the needs of the City's residents and businesses, both present and futute. PUG2 Work with private utility companies to allow them to provide service in a way that balances cost-effectiveness with environmental protection, aesthetic impact, public safety, and public health. PUP17 The City should require that site -specific utility facilities such as antennas and substations be reasonably and appropriately sited and screened to mitigate adverse aesthetic impacts. (2) It is consistent with all applicable provisions of this chapter; This proposal in compliance with all applicable provisions of the FWCC. (3) It is consistent with the public health, safety, and welfare; This proposal is not detrimental to public health, safety, or welfare, of the residents of Federal Way. (4) The streets and utilities in the area of the subject property are adequate to serve the anticipated demand from the proposal; and No street or utility modifications are necessary. (5) The proposed access to the subject property is at the optimal location and configuration. There is no new ingress/egress proposed. The site will continued to be accessed via the existing driveway from Eighth Avenue South. In responding to the pre -application letter, please see the following: 2. SEPA checklist is included with this application package. 3. Fees will of course be paid. 4. PWSF Prioritized Location. Please see code compliance above for response to this section. 5. PWSF Development Standards. Please see code compliance above for response to this section. 6. Standards for Electronic Equipment Enclosures. Please see code compliance above for response to this section. 7. Screening Standards for all PWSF's: The equipment enclosure is designed to match the style of the existing CW block structures on site. 8. Significant trees: This application does not include the removal of any trees, significant or otherwise. 9. Application requirements: a. Please see attached plans and photographs. b. Given the existing mature vegetation surrounding the subject parcel, photo simulations do not show much of a change. Please see attached photos (labeled to show the placement of antennas, since they can't be seen). The subject water tank can not be seen from the intersection of the access driveway and the ROW. c. Please see attached plans (A-3) for elevations of the proposed antennas. Page A-4.2 shows the detailed elevation for the proposed equipment enclosure. d. A propagation map is included with this application. e. Sites operated by other carriers were not observed within approximately 1 mile from this site location. AT&T currently has two sites within that realm, and they are shown on the propagation maps. If the city has additional information it can be included. £ Please see page A-1 for a full site overview. 11. It is understood that an EMT study will be required within six months of the Certificate of Occupancy/Final Inspection. 13. Misc: a. Proposed signs are detailed on page A5.1/A5.2. These signs the FCC required site identification signs as well as RF warning signs. They will be located on the CMU block building. b. The impervious surface area has been added. c. Coax will be routed underground from the equipment location to the water tank. d. Note 11 has been added. In regards to the Building Criteria, Five (5) sets of stamped plans, including structural connection details, will be submitted with the building permit. King County Health Department review is not applicable for this proposal. Thank you for taking the time to review all of this. If you need to get a hold of me, I can be reached at 206-604-7760 or kiohnson@realcomassoc.com. Sincerely, REALCOM ASSOCIATES, INC., representing the New AT&T 0 Katite son Site Acquisition & Zoning Manager RE L C 0 M qik- t� � - 0 0 -Up� June 21, 2007 Mr. Andy Bergsagel City of Federal Way Department of Community Development Services 33325 Eighth Avenue South Federal Way, WA 98003 Re: AT&T @ Ranen — Federal Way/Buena (WA931) 31001 Eighth Avenue South, Lakehaven Water Tank Dear Andy, Fo� 0 �'Cll As required for the processing of a wireless application (PWSF) in the City of Federal Way, the applicant, AT&T, agrees to allow for the potential collocation of additional PWSF equipment by future providers within this site location. If you have questions, I can be reached at 206-604-7760 or kjohnson@realcomassoc.com. Sincerely, REALCOM ASSOCIATES, INC., representing the New AT&T Katie J on Site Acqusition & Zoning Manager JUN 2 5 2007 CITY OF FEDFRAl4 WAY BUILDING DEPT. REALCOM Associates, LLC • 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007 • p 425-274-4444 f 425-274-4449 www.realcomassoc.com CITY OF FEDERAL WAY DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES DEVELOPMENT REVIEW COMMITTEE TRANSMITTAL DATE: July 6, 2007 TO: Will Appleton, Development Services Manager Scott Sproul, Assistant Building Official Brian Asbury, Lakehaven Utility District Chris Ingham, Federal Way Fire Department FROM: Andy Bergsagel �.A� FOR DRC MTG. ON: July 12, 2007 - Meeting to determine completeness FILE NUMBER(s): 07-103419-00-UP RELATED FILE NOS.: 07-103420-00-SE 07-103422-00-CO PROJECT NAME: AT&T @ BUENA (WA931) PROJECT ADDRESS: 31001 8TH AVENUE S. ZONING DISTRICT: RS 7.2 PROJECT DESCRIPTION: Installation of wireless antennas onto an existing water tank. Associated transmission equipment will be located in a new CMU shed. LAND USE PERMITS: PROJECT CONTACT: MATERIALS SUBMITTED: Process III + SEPA Katie Johnson REALCOM ASSOCIATES 14432 EASTGATE ST Suite 260 206-604-7760 (Primary) Plans • Cover letter + code analysis • SEPA checklist • Photographs • Coverage Map • Map of Lease Area • Title Report �Q'S Legal Description WA931—Ranen PARCEL A: THE SOUTH HALF OF THE NORTHEAST QUARTER OF THE SOUTHEAST QUARTER OF THE NORTHWEST QUARTER OF SECTION 8, TOWNSHIP 21 NORTH, RANGE 4 EAST, WILLAMETTE MERIDIAN, IN KING COUNTY, WASHINGTON; EXCEPT THE NORTH HALF OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF THE SOUTHEAST QUARTER OF THE NORTHWEST QUARTER OF SAID SECTION 8; AND EXCEPT THE SOUTHWEST QUARTER OF THE SOUTHWEST QUARTER OF THE NORTHEAST QUARTER OF THE SOUTHEAST QUARTER OF THE NORTHWEST QUARTER OF SAID SECTION 8; AND EXCEPT THE EAST 30 FEET AND TOGETHER WITH THE WEST 30 FEET AND THE SOUTH 30 FEET OF THE SOUTHWEST QUARTER OF THE SOUTHWEST QUARTER OF THE NORTHEAST QUARTER OF THE SOUTHEAST QUARTER OF THE NORTHWEST QUARTER OF SAID SECTION 8; AND FURTHER EXCEPTING THE WEST 147 FEET OF THE EAST 177 FEET OF THAT PORTION OF THE SOUTH HALF OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF THE SOUTHEAST QUARTER OF THE NORTHWEST QUARTER OF SECTION 8, TOWNSHIP 21 NORTH, RANGE 4 EAST, WILLAMETTE MERIDIAN, LYING NORTHERLY OF THE SOUTH 30 FEET THEREOF. PARCEL B: THE WEST 120 FEET OF THE NORTH HALF OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF THE SOUTHEAST QUARTER OF THE NORTHWEST QUARTER OF SECTION 8, TOWNSHIP 21 NORTH, RANGE 4 EAST, WILLAMETTE MERIDIAN, IN KING COUNTY, WASHINGTON; EXCEPT THE EAST 30 FEET THEREOF CONVEYED TO KING COUNTY, WASHINGTON FOR ROAD BY DEED RECORDED UNDER RECORDING NUMBER 2597904, IN KING COUNTY, WASHINGTON. r. at&t September 18, 2007 David Swartz Repeater Operations, P.O. Box 23415 Federal Way Amateur Radio Club Federal Way, WA 98093 Re: WA931--Federal Way Buena site Dear Mr. Swartz, AT&T Mobility T: 425.580.8763 P.O. Box 97061 F: 425.580.9976 Redmond, WA 98073-9761 www.att.com The following is in response to your concern that AT&T's proposed site located at 30929 8th Ave South, Federal Way, WA 98003, may cause intermodulation interference to the Federal Way Amateur Radio Club's radio repeater at that location. While a study shows potential third order intermodulation products landing on your repeater's channel, a computer study is not a guarantee of interference. The robust nature of your radio equipment and ours makes intermod being generating your equipment or our equipment unlikely. However, other sources for signal -mixing may exist in the environment and cannot be ruled out as a potential interference source. AT&T could retune our network to create a channel set for this site that is free of theoretical third order intermod products. However, retuning is something we do to improve our overall network, not just a single site. I propose we tackle the situation as follows. Before the AT&T site goes into commercial service, let's perform an on/off test to determine if any interference is experienced by your facilities. If there is any interference, we will mitigate the interference before the AT&T site becomes commercially available. Further, should the Federal Way Amateur Radio Club determine that your equipment is suffering from any interference after the AT&T site becomes commercially available, please contact me directly. I will dispatch an engineer to work with you and your personnel to troubleshoot and mitigate the interference as quickly as possible. I will submit a copy of this letter into the record for the land use review for the City of Federal Way. If I can be of further assistance in this matter please do not hesitate to contact me. Sincerely, Kevin Chu Director, Pacific Northwest RF Engineering usa CW : vc J Sp0!15OI OI ifiE U.S. 0!yrtipir. ;pam Page 1 of 2 Laura Kim - AT&T @ Buena (FWARC response) ��— From: "Swartz, Dave" <dave.swartz@weyerhaeuser.comy q�� To: "Laura Kim" <Laura.Kim@ cityoffederalway.com> , �y Date: 9/14/2007 2:41 PM Q ��- Subject: AT&T @ Buena (FWARC response) CC: David a@swartzfamily.org> \� 1r 1r Laura, I did not receive a copy of the letter from Kate Johnson that you_are referring to. Regarding a conclusion that satisfies our concern regrettably the opposite is the case. From the frequencies provided by AT&T we did an intermodulation analysis of their proposed frequencies and determined that these frequencies have a strong potential to mix with the frequencies used by our transmitter and produce an interfering signal on our receiver. I delivered the analysis we performed to your office and this report should be included in your project file. Kirk Swanson, an engineer with AT&T confirmed that our calculations are correct. The frequencies chosen by AT&T for this project are incompatible with any Amateur Radio Service two meter band repeater. All Amateur Radio Service two meter repeaters use a separation between the transmitter and the receiver of 600 KHz in frequency. AT&T is proposing to use a separation between the frequencies of two of their transmitters of exactly 600 KHz. We have requested that they choose a different frequency for some of their proposed transmitters. This solution was proposed by Kirk Swanson (AT&T engineer) to Anne Lee (AT&T engineer responsible for this market.). She rejected this suggestion (September 10th) because of the cost and disruption to their plans. I again talked to her two days ago (September 12th) and she was going to talk to her supervisor on how to proceed. I suggested that she do one of the following. Option 1. Use a different frequency for the relevant transmitters which will not generate interference to our system. Option 2. Write your office and the FWARC a letter committing to immediately shut off their transmitter should interference occur to the Federal Way Amateur Radio Clubs receivers and to not turn the transmitter back on until the source of the interference is eliminated. (This option was designed to avoid extensive review and hearings at a later date should interference occur.) a third option also exists. Option 3. Scale back the scope of the project to not use as many transmitters. I have not heard back from them on their chosen course of action. I believe that absent their election to pursue one of these three options, AT&T's position is to address any interference that may occur at the time their site becomes operational. Anne Lee communicated to me that it is difficult for her to get support from her management for a frequency redesign prior to the occurrence of actual interference. Clearly this is a reactive instead of a proactive stance. We would prefer that they develop a strategy for eliminating this potential interference to our system prior to beginning construction. AT&T is clearly hoping that they will be lucky and that no intermodulation products will occur. Should your office decide to allow them to proceed, despite the documentation that we have provided showing the potential that exists for interference, we do have other remedies at our disposal that can be exercised when and if interference occurs. The lease they signed with the Lakehaven Utility District requires them as the last tenant to the site to not interfere with the other radio systems at the site. The Federal Communications Commission (FCC) regulations also require that that when two licensed system are experiencing harmful interference that it is the responsibility of both system to work together to eliminate the interference. We take interference to our receiver very seriously. There is no denying that our repeater system is valuable file://C:\Documents%20and%20Settings\default\Local%20S ettings\Temp\XPgrpwise\46E... 9/ 14/2007 Page 2 of 2 .-1 1'-) and important to the people of Federal Way. It must remain free from interference. Thank you for your support and help with this matter. Best wishes, David Swartz Chairman, Repeater Operations Committee FWARC. 253-924-6291 work From: Laura Kim [mailto:Laura.Kim@cityoffederalway.com] Sent: Friday, September 14, 2007 10:20 AM To: Swartz, Dave Subject: Fwd: RE: AT&T @ Buena Dave, Can you confirm that you have received the letter from Katie Johnson at REALCOM and that you have discussed these issues and have come up with a conclusion that satisfies your concerns? Laura Kim Associate Planner City of Federal Way PO Box 9718 33325 8th Avenue South Federal Way, WA 98063-9718 253-835-2641 lau ra. k i m Ca)citvoffe d era lway. co m >>> "Katie Johnson" <kjohnson@realcomassoc.com> 9/14/2007 9:39 AM >>> We've continued to work with the FWARC, and there should be no impact to the land use process at this point. Katie Johnson 206-604-7760--Mobile kiohnson_cr realcomassoc.com From: Laura Kim [ma ilto: Laura. Kim@cityoffederalway.com] Sent: Friday, September 14, 2007 9:35 AM To: Katie Johnson Subject: RE: AT&T @ Buena To Andy dated August 23, 2007 regarding to EMF studies to be sent to FWARC. file://C:\Documents%20and%20S ettings\default\Local%20Settings\Temp\XPgrpwise\46E... 9/14/2007 R E * L C 0 M August 23, 2007 City of Federal NVay Depariment of Connnunity Development 33325 Eighth Avenue South Federal Way, WA 98063 Re: Proposed Cingular Wireless Site at Federal Way - Buena (WA-931) Response to Letter from [lie Federal Way Amateur Radio Club Aiidy, Dave Swartz and I spoke at the end of last week. I will be forwarding liiin our exact frequencies once I get them from the RF engineer (slid engniccr being out until next Monday - 27"'). I want to make sure we're all on the saune page. The Federal Way Amateur Radio Club (1NVARC) is expressing the concern about possible iil[cil&rence, and want to verify there is an ability to correct the issue; there is not a specific worry or expectation that at&( willinterfere. Dave, I believe we agreed that this was lie case when we spoke last week. The bottom line is at&t should not cause iiitcrfcrence witi the FWARC's shortwave radio broadcasting (and in fact shau-c space at another location ill Federal Wa)). All necessary reports quid filings, required by code and added as conditions of approval, will be submitted within the required timeframes. As noted in the letter submitted by F\NTARC, these operators do provide all importauit cominunity func6oii, and all wireless broadcasting pal -tics shaur a combined responsibility for coexisting in this inodern clay and age of inultiple providers. I would like to suggest that required EMF studies be sent to FNVARC at the same time they are submitted to Federal Way, after construction complete. This should actually be able to be finished Nvithin 3 months of the site being completed integrated and "on -air". (Lakehaven has approved the proposed wireless installation, by the way. As property owner, they have already reviewed the entire installalioii, as proposed, and executed a lease agreement.) Additionally, Dave, I will lonvard those frequencies, as soon as I receive them from RF. Thank you! Sincerely, REALCOM ASSOCIATES, I.C', 64ulir NMJmlcss Katic,1c inson 14432 Eastgate Way SE, Suite 260 • Bellevue, WA 98007 p 425-274-4444 0 f425-274-4449 Page 1 n-[-- Andy Bergsagel - RE: FCC Spectrum Chart (at&t @ Federal Way - Buena) From: Andy Bergsagel To: Dave Swartz; Katie Johnson Date: 8/15/2007 8:57 AM Subject: RE: FCC Spectrum Chart (at&t @ Federal Way - Buena) Dear Katie, I think the best thing for you to do would be to submit a letter (on letterhead) in response to Dave's e-mail. Please use the resubmittal form (available at www.cityoffederalway.com eNote). You can mail it to the City, if you are not in the area. How soon after installation do you think you can get a report on the EMF/interference? Dear Katie and Dave: Please note the following Code excerpt. In the event there is a problem, the City can invoke this section to remedy the situation: 22-972 EMF standards and interference. (a) The applicant shall comply with federal standards for EMF emissions. Within six months after the issuance of its operational permit, the applicant shall submit a project implementation report which provides cumulative field measurements of radio frequency (EMF) power densities of all antennas installed at the subject site. The report shall quantify the EMF emissions, compare the results with established federal standards, and provide a statement that the EMF emissions are within established federal standards. Said report shall be subject to review and approval of the city for consistency with the project proposal report and the adopted federal standards. If on review, the city finds that the PWSF does not meet federal standards, the city may revoke or modify the permit. The applicant shall be given a reasonable time based on the nature of the problem to comply with the federal standards. If the permit is revoked, then the facility shall be removed. (b) The applicant shall ensure that the PWSF will not cause localized interference with the reception of area television or radio broadcasts or the functioning of other electronic devices. If on review of a registered complaint the city finds that the PWSF interferes with such reception, the city may revoke or modify the permit. The applicant shall be given a reasonable time based on the nature of the problem to correct the interference. If the permit is revoked, then the facility shall be removed. (Ord. No. 97-300, § 3, 9-16-97; Ord. No. 00-363, § 14, 1-4-00) Andy Bergsagel Planner City of Federal Way 33325 8th Avenue S. P.O. Box 9718 Federal Way, WA 98063 253-835-2644 Phone 253-835-2609 Fax andy.bergsagel@cityoffederalway.com file://C:\Documents and Settings\default\Local Settings\TempAPgrpwise\46C2BFE6CHP... 8/15/2007 (8/15/2007y Andy Bergsagel - FW: FCC Spp,--trum Chart (at&t @ Federal Way - Buena) - - -- -Rage 1 From: "Katie Johnson" <kjohnson@realcomassoc.com> To: "Andy Bergsagel" <Andy.Bergsagel@cityoffederalway.com> Date: 8/13/2007 4:22 PM Subject: FW: FCC Spectrum Chart (at&t @ Federal Way - Buena) Attachments: Operating Spectrum.pdf Andy This is a very busy chart, but I've highlighted on the right side of page two the bands in question. Below is the link on the FCC webpage where this document can be found, if there are any other questions. hftp://www.fcc.gov/Bureaus/OPP/Working_papers/oppwp38chart.pdf AT&T will operate in the 850/1900 MHz ranges, well outside of the range of the Federal Way Amateur Radio Club. If you need further information, please let me know! Katie Johnson Site Acquisition & Zoning Manager RealCom Associates, LLC 14432 SE Eastgate Way, Suite 260 Bellevue, WA 98007 206-604-7760--Mobile 425-274-4449--Fax kjohnson@realcomassoc.com <mailto:425-274-4449--Faxkjohnson@realcomassoc.com> "Wrinkles should merely indicate where smiles have been." Mark Twain U.S. Spectrum Allocations- 300 - 3000 MHz A Vertical Bar Chart With Frequency Bands Shown Approximately To - ---Scale- John R. Williams OPP/FCC November 2002 Small hands have been enlarged slightly for lcgibiIity. This chart is ppt[in ized for printfitg an legal sire paper, with a color printer. Services and foolnote4 in the expanded chart were transferred directly from the ["CC" (online Allocation TaWe (Rc%i%vd as of Septcinher 25. 200 t) and are believed to be complete and accurate, but have not heen cross-checked. Some errors are therefore ltnsaible. -Hie official FCC'rable of [-requeney Allocations is the one published in the Federal Register. The text of foolnot" h" not been included in tkjj4 Churl but is a5'ailable on lhf FCC'.$. ivebsite. TIke "Special Categories" eoIumnv and general service nAmes shown on the index page and on certain bands in the expanded chart Are the author'~ own derivatioms and do not nectssarily correspond to 0ffrial FCC lerminology. Please direct all comments, questions or torrectihnh to Iltc author at jwilliam@fcc.gov. �Oge Index to Expanded Chart 300 400 500 600 700 800 900 1000 110C 1200 1300 140C 150C 160C 170C 180C 190( 200C 210C 220( 230( 240( 250( 260( 270( 280( 290( 3001 UNITED STATES SPECTRUM ALLOCATIONS 300 - 3000 MHz BAND iz SPECIAL CATEGORIES OF USE o g GENERAL SERVICE DESCRIPTION H [p[ (SEE INCICATED PAGE FOR AN EXPANDED VIEW Vv1TH SERVICE NAMES AND FOOTNOTES FROM THE FCC% ALLOCATION TABLE) O Q .�d. `G NOTE Smite lames useE on Mm PYe ere NeaWwfc am Eenvdl,onseN roI FCCMminoloQy - N LL iwueam Q CWW O 3 W e} O �g O D m Q FIXED, MOBILE, SATELUTE, NAVIGATION, WEATHER AIDS (322-450 MHz) Page 1 (322 - 512 — -PRIVATE LAND MOBILE (450-070 MHz) MHz) it 42 I 42 f I 96 i _CORE UHF N BAND CHANNELS 1451 Ezduding Ch. 37. (470M8 MHz) Page 2 _ RADIOASTRONOMY (512 - 746 64 MHz) RE✓L.LOCATED TV CHANNELS 52-59-'Lower 700 MHz' (696-746 MHz) RE►LLOCATEO N CHANNELS 60-69 -'Upper 700 MHz' (746-806 MHz) Page 3 (746 - 960 CELL" MHz) ur+ucEN ss BAND i3 1bOH3L Page 4 1 - NAVIGATION (960 - 1215 MHz) - RADAR • 1 1 1 ,1 Page 5 NAVIGATtoN (1215 - 1435 F FT7rED, MOB. RADAR, NAVIGATION (GPS 1361 05 MHz) MHz) F-V EATNER AIM ��pp�vyykk-- �L'11�L'L I • v L AERONNJ71CAL TELEMETRY Page 6 g ;tif: '1 L•SAND MSS DOWN LINK (POSSIBLE MSS FLEX) (1435 - 1675 ,ti 1 GPS[1575A2 MHz) SATEUJTE, WEATHER AIDS, RADIOASTRONOMY, NAVIGATION MHz) Ism L•BAi',0MSS UP LINK (POSSIBLE MSS FLEX) �4 WEATI+532 SATELLITES I TRANSFER BAND (POSSIBLE 3G) Page 7 1 1 95 GOVERNMENT FIXED AND MOBILE (POSSIBLE 3G) (1675 - 1930 MHz) • 1 1 .1 60 -PCs •1 1 3S I .84-2GHzMSS UPLINK (POSSIBLE MSS FLEX, POSSIBLE 3G) Page (1930 - 2165 1 1 1 -SPACE, FIXED, MOBILE i MHz) I 40 1 � -FIXED AND MOBILE (POSSIBLE 3G) 11 35 1 35:J-2 GHz MSS DOWNUNK(POSSIBLE MSS FLEX, POSSIBLE 3G) 11 • 1 , 1 - -FIXED, MOBILE, SATELLITE Page 9 (2165 - 2390 _WCS BAND MHz) ` `BARS I • 1 -( OSSIBLE 3G) 2390.2402 24tiT-248 3S -UNUCENSED_I ) 2450-?A83.5 33.5 Page 10 (2390 - 2665 MHz) / 1 1ss -MDS-ITFS (POSSIBLE 3G) • 1 3s I Page 11 (2665 - 2900 11 11 11 MHz) Page 12 • 1 1 1 1 11 1 (2900 - 3100 i MHz) I 3100 COLUMN TOTALS 2776 222 I 200 70 1 465 123.47 6 116 70 78 %OFTOTAL 1000 8.0 1 7.2 25 17.5 1 44 02 42 25 26 John R Wiliams FCCIOPP 377(1002 Page 1 of 2 Andy Bergsagel - RE: FCC Spectrum Chart (at&t @ Federal Way - Buena) From: "Swartz, Dave" <dave.swartz@weyerhaeuser.com> To: <Andy.Bergsagel@cityoffederalway.com> Date: 8/14/2007 7:10 PM Subject: RE: FCC Spectrum Chart (at&t @ Federal Way - Buena) CC: "Katie Johnson" <kjohnson@realcomassoc.com> Andy, We agree that their primary transmitter frequencies will not be in the amateur radio frequency allocation. Clearly they will be using different frequencies. There are lots of other ways that interference can occur. Have they done an interference study that includes looking at intermodulation products? In order to do such a study they need to identify the specific frequencies that their transmitters will be using. They need to identify the frequencies that the other transmitters that are in use at the site will be using. They will also need to identify the frequencies that the receivers in use will be listening on. Here is a real world example. King County builds radio sites to support police and fire radio transmissions. In these sites you have 24 transmitters that are in the 800 MHz frequency range. Two of those transmitters are 600 KHz apart in frequency. An Amateur Radio repeater that is collocated with this system uses 600 KHz for the separation between it's transmitter and receiver. When the two 800 MHz transmitters that are 600 KHz apart in frequency are on the air at the same time as the amateur radio transmitter (146.76 MHz) the signals mix creating a strong signal on the receiver's input frequency (146.16 MHz). Because the offending signal is directly on the input frequency of the receiver it is impossible to filter out the interference. The only practical solution is for those two 800 MHz transmitter to not be on the air simultaneously. When engineering their system AT&T needs to consider the potential for interference to other systems as a part of their design. No where in the documentation that was submitted by AT&T that you furnished the Federal Way Amateur Radio Club was their any reference to the pre-existing systems at that site. As far as I can tell their is no plan in place by AT&T to ensure that their transmitters do not interfere with the pre-existing systems that are present at their proposed site. Their documentation certainly does not list the specific frequencies that they are proposing to use. Their documentation in no way indicates that they are even aware that there are other radio systems in use at this site. It would be nice to see a copy of their plan for preventing harmful interference to other systems prior to the issuance of any permits. In Western Washington an organization exists who's purpose is to address interference issues between different users of the radio frequency spectrum. It's called the Western Washington Cooperative Interference Committee. They maintain a web site at htt :! wvrw.wwciC.Or ! . They have created a document entitled WWCIC Engineering Standard #6 Rev. C (02-97)(hitp://www.wwcic.orglwwcic_es.html ). This document lists the minimum best practices that should be employed in site engineering to minimize radio interference. Let me reiterate our position that we first stated in our previously submitted letter. We welcome AT&T to locate at the Lakehaven Tanks 1 &4 site. However it is critical that their equipment in no way interfere with our equipment. Thank you for your assistance with this matter. Please don't hesitate to contact me if you have any further questions. Sincerely, David Swartz Chairman Repeater Operations, Federal Way Amateur Radio Club I have provided some references that may be helpful in understanding radio interference. file://C:\Documents and Settings\default\Local Settings\Temp\XPgrpwise\46C1FE29CHP... 8/15/2007 Page 2 of 2 This web site provides a definition of several types of interference that can be present at a radio site. http_I�www,Ibagroup.com/associates[in tfay .ph p The following web sites that discuss intermodulation. They start from easy to more academic papers. Intermodulation Performance and Measurement of Intermodulation Components htt :I� /mpg.com.au/Idbutler/Intermodulation.htm Intermod: Getting the upper hand by Harold Kinley Part 1 - http://mrtmag.com/images/archive/04teksgkwgb.pdf Part 2 - http://mrtmag.comlimageslarchive/05tekspkweb.pdf Mr. Kinley is a regular contributor to Mobile Radio Technology Magazine and is well respected in the industry. Intermodulation Interference in the GSM/UMTS Bands httR:Ildragao.co.it.pt/r-onftele2OO1 / roc a 005. df From: Katie Johnson[mailto:kjohnson@realcomassoc.com] Sent: Monday, August 13, 2007 4:22 PM To: Andy Bergsagel Subject: FW: FCC Spectrum Chart (at&t @ Federal Way - Buena) Andy This is a very busy chart, but I've highlighted on the right side of page two the bands in question. Below is the link on the FCC webpage where this document can be found, if there are any other questions. http;l/WA W.fcc.gpv/Burgaus/OPELwprrkOiLp pers/oppwp38crdf AT&T will operate in the 850/1900 MHz ranges, well outside of the range of the Federal Way Amateur Radio Club. If you need further information, please let me know! Katie Johnson Site Acquisition & Zoning Manager RealCom Associates, LLC 14432 SE Eastgate Way, Suite 260 Bellevue, WA 98007 206-604-7760--Mobile 425-274-4449--Fax kiioh isonQrealcornassoc.com "Wrinkles should merely indicate where smiles have been. " Mark Twain file://C:\Documents and Settings\default\Local Settings\Temp\XPgrpwise\46C1FE29CHP... 8/15/2007 el 4k CITY OF Federal 'Flay NOTICE OF LAND USE APPLICATION AND OPTIONAL DETERMINATION OF NONSIGNIFICANCE (DNS) Project Name: AT&T @ Buena (WA931) Project Description: This proposal is to add up to 12 panel antennas to support "The New AT&T" wireless network (formerly Cingular Wireless). The antennas will be located just below the rim of the water tower, which is about 81 feet above the ground, and they will be painted to match. The antennas measure approximately 6'8" x 10" x 5". Associated transmission equipment will be housed in a 209 square -foot shed to the east of the tower. Applicant: The New AT&T; PO Box 97061; Redmond, WA 98073 Agent: Katie Johnson c/o Realcom Associates; 14432 SE Eastgate Way #260; Bellevue, WA 98007 Owner: Lakehaven Utility District; PO Box 4249; Federal Way, WA 98063 Project Location: 31001 8 h Avenue South Date Application Received: June 25, 2007 Date Determined Complete: July 23, 2007 Date of Notice of Application: July 28, 2007 Comment Due Date: August 13, 2007 (5:00 p.m.) SEPA File #: 07-103420-SE Permits Required: Process III Approval (File #07-103419-00-UP) Relevant Environmental Documents Are Available at the Address Below: X Yes .,_ No Optional Environmental Determination: Based upon review of a completed environmental checklist and other information on file with the City, it is anticipated that a Determination of Nonsignificance (DNS) will be issued for the proposed project. The optional DNS process in WAC 197-11-355 is being used. It is likely that the City of Federal Way will determine that the project will not have a probable significant adverse impact on the environment and an Environmental Impact Statement (EIS) will not be required under RCW 43.21C.030(2)(c). Existing Environmental Document(s): SEPA Checklist Integrated Comment Period: Consistent with the provisions of WAC 197-11-355, a single integrated comment period will be utilized to obtain comments on the Notice of Land Use Application and Notice of Filc No. 07-103419 Doc. ID 41556 • 1 _L�t Optional Determination of Nonsignificance. This may be the only opportunity to comment on the environmental impacts of the proposal. Any person may submit written comments on the land use application or the environmental impacts of the proposal to the Director of Community Development Services by 5:00 p.m. on August 13, 2007. Only persons who submit written comments to the Director, or specifically request a copy of the decision, may appeal the Process III decision. However, any interested party may appeal the environmental threshold determination. Details of appeal procedures for the requested land use decision will be included with the written decision. Issuance of Final Environmental Determination: The final DNS may be issued without a second comment period, unless timely comments identify probable significant adverse impacts that were not considered by the Notice of Optional DNS. A copy of the DNS may be obtained upon request. Development Regulations to Be Used for Project Review Known at this Time: Federal Way City Code (FWCC) Chapters 18, 21, and 22 Consistency with Applicable City Plans and Regulations: Development of the site is subject to all applicable City codes andregulations, including the FWCC chapters pertaining to zoning, environmental protection, landscaping, community design guidelines, environmental protection, and planning and development. The official project file is available for public review at the Department of Community Development Services, 33325 8`b Avenue South. Comments may be mailed to PO Box 9718, Federal Way, WA 98063. City Staff Contact: Andy Bergsagel, Associate Planner Phone: 253-835-2644 File No. 07-103419 Doc I D. 41556 Wireless Provider: Site Name: Project Address: Parcel Number: Pitt tquvn�*.r: Prepared by Realcom Associates The New AT&T (f/k/a Cingular Wireless) A T $ T @_�` NA 6v%a , (WA931) 30929 8th Avenue South 082104-9029 O7 - LO14.11- oO-up DEPAR"fMENT OF CONINIUNITY DEVELOPMENT SERVICES 33325 81h Avenue South PO Box 9718 CITY OF Federal Way WA 98063-9718 253-835-7000; Fax 253-835-2609 Fede� VAJFJ wA .cityoffederolway.com DECLARATION OF DISTRIBUTION hereby declare, under penalty of perjury of the laws of the State of Washington, that a: ❑ Notice of Land Use Application/Action ❑ Notice of Determination of Significance (DS) and Scoping Notice ❑ Notice of Environmental Determination of Nonsignificance (SEPA, DNS) ❑ Notice of Mitigated Environmental Determination of Nonsignificance (SEPA, MDNS) 14 Notice of Land Use Application & Anticipated DNS/MDNS ❑ FWCC Interpretation ❑ Other ❑ Land Use Decision Letter ❑ Notice of Public Hearing before the Hearing Examiner ❑ Notice of Planning Commission Public Hearing ❑ Notice of LUTC/CC Public Hearing ❑ Notice of Application for Shoreline Management Permit ❑ Shoreline Management Permit ❑ Adoption of Existing Environmental Document was [mailed ❑ faxed ❑ e-mailed and/or ❑ posted to or at each of the attached addresses on oZ 2007_ Project Name File Number(s) Signature 'Be -# Date -0 K:\CD Administration Files\Declaration of Distribulion_doc/Last printed 1/8/2007 4:34:00 PM CITY OF Federal Way NOTICE OF LAND USE APPLICATION AND OPTIONAL DETERMINATION OF NONSIGNIFICANCE (DNS) Project Name: AT&T @ Buena (WA931) Project Description: This proposal is to add up to 12 panel antennas to support "The New AT&T" wireless network (formerly Cingular Wireless). The antennas will be located just below the rim of the water tower, which is about 81 feet above the ground, and they will be painted to match. The antennas measure approximately 6'8" x 10" x 5". Associated transmission equipment will be housed in a 209 square -foot shed to the east of the tower. Applicant: The New AT&T; PO Box 97061; Redmond, WA 98073 Agent: Katie Johnson c/o Realcom Associates; 14432 SE Eastgate Way #260; Bellevue, WA 98007 Owner: Lakehaven Utility District; PO Box 4249; Federal Way, WA 98063 Project Location: 31001 8 b Avenue South Date Application Received: June 25, 2007 Date Determined Complete: July 23, 2007 Date of Notice of Application: July 28, 2007 Comment Due Date: August 13, 2007 (5:00 p.m.) SEPA File #: 07-103420-SE Permits Required: Process III Approval (File #07-103419-00-UP) Relevant Environmental Documents Are Available at the Address Below: X Yes _ No Optional Environmental Determination: Based upon review of a completed environmental checklist and other information on file with the City, it is anticipated that a Determination of Nonsignificance (DNS) will be issued for the proposed project. The optional DNS process in WAC 197-11-355 is being used. It is likely that the City of Federal Way will determine that the project will not have a probable significant adverse impact on the environment and an Environmental Impact Statement (EIS) will not be required under RCW 43.21C.030(2)(c). Existing Environmental Document(s): SEPA Checklist Integrated Comment Period: Consistent with the provisions of WAC 197-11-355, a single integrated comment period will be utilized to obtain comments on the Notice of Land Use Application and Notice of File No. 07-103419 Doc, I.D. 41556 Optional Determination of Nonsignificance. This may be the only opportunity to comment on the environmental impacts of the proposal. Any person may submit written comments on the land use application or the environmental impacts of the proposal to the Director of Community Development Services by 5:00 p.m. on August 13, 2007. Only persons who submit written comments to the Director, or specifically request a copy of the decision, may appeal the Process III decision. However, any interested party may appeal the environmental threshold determination. Details of appeal procedures for the requested land use decision will be included with the written decision. Issuance of Final Environmental Determination: The final DNS may be issued without a second comment period, unless timely comments identify probable significant adverse impacts that were not considered by the Notice of Optional DNS. A copy of the DNS may be obtained upon request. Development Regulations to Be Used for Project Review Known at this Time: Federal Way City Code (FWCC) Chapters 18, 21, and 22 Consistency with Applicable City Plans and Regulations: Development of the site is subject to all applicable City codes and regulations, including the FWCC chapters pertaining to zoning, environmental protection, landscaping, community design guidelines, environmental protection, and planning and development. The official project file is available for public review at the Department of Community Development Services, 33325 80'Avenue South. Comments may be mailed to PO Box 9718, Federal Way, WA 98063. City Staff Contact: Andy Bergsagel, Associate Planner Phone: 253-835-2644 File No 07-103419 Doc. I D. 41556 Vi C-;.i�s M.e Wireless Provider: The New AT&T (f/k/a Cingular Wireless) Site Name: A T K T@ nu p h a ( WA 9 3 l) Project Address: 30929 8th Avenue South Parcel Number: 082104-9029 Fitt Kuv,%4.: 07 - L034iq - Prepared by Realcom Associates Print Map Page Page I of 5 0 AT LQ King County MCMM OCEM 0� 300 feet radius Parcel Ma 24133095?0 2141 JIA10720 Z41330300 116*11049267 ?7;11.50QD1yV V) 2-T i 3390?611 9 V2 10 4 yl LJ2 fe- d4133011000 241133005KR 2.i132-00280 OEr71UU0180 S -MaTi f ST 247334006PO 741339L1nWN S WgTfl ST 24133 F -T ,fadv) I 2 4 123 1 - .9r,49 2�W73XJvvv I - 1 931590CLOWO aM2)94909.5 P3109600 QUUMP1358 I 2,113i9beeLl Z, - . 031w)"WO ,?413HOQPrl2'i7:!lUO2JCI y376D_wbo PEIWULU,19 CL J 330 ul r4 o 5 MTJ I ST WJ'9U 241321,11 1 R-111 4N. 39U 2vnEIIS60 2-1 pj-'111-1149 y3iV090,11, 24i33919511 Federal %Ala 66-11 26119260 ?413AJ1v11.t 3 6O?,2Ub926J e.;. 1 2 S 0 9; 1 1). VRI I U3VO4LikZk U81 BJ09(iAl V J fi." 11s, IL1491 PEI M Lis 1 $6QLJ, 6o Ll 19 1� y I If P Eli�v I 9�13 1 �,q VE !16S001.19 9 Al I 94p;?36 9621 L"I LJ9 081e59!Q;9 9 �W 1 Eff I Y 2 9 9 08 Oe" 9 J 6 - L-1 2W6 MIT COMY - Q v 27 lb 911 9 3 Parcel Number 0821049029 Address Zipcode Taxpayer LAKEHAVEN UTILITY DISTRICT 'he information included on this map has been compiled by King County staff from a variety of sources and Is subject to change dllhotA notice. King County makes no representations or warranties, express or implied, as to accuracy, completeness, timellness, or fights to the use of such information- King County shall not be liable for any general, special, Indirect, incidental, or consequential lamage s including, but not limited to, lost revenues a r lost profits resu itl ng from the use or misuse of the Information contained on this r1a D. Any sale of this Ma D or info rmatlon on this map is prohibited except by written permission of King County.' http://www5.metrolce.gov/pareelviewer/Print—Process.asp 5/2/2007 PARCEL #0818500010 PARCEL #0818500610 PARCEL *2413300030 Patricia George -Buchanan Anthony Byron Fields James & Pearl Rhyner 801 S 310t" PI 804 S 310t" PI 31112 51" Way S Federal Way, WA 98003 Federal Way, WA 98003 Federal Way, WA 98003 PARCEL *0818500020 PARCEL #0821049029 PARCEL #2413300040 Michael Lynn Spencer Lakehaven Utility District Christopher & Jennifer Grey 803 S 3101" PI PO Box 4249 31108 51" Way S Federal Way, WA 98003 Federal Way, WA 98003 Federal Way, WA 98003 PARCEL #0818500030 PARCEL *0821049045 PARCEL #2413300050 Kathleen Louise Smiley Kelli Ione Cook Jonarthur Pinney 807 S 3101" PI 423 S 329t" Lane 28618 271" PI S Federal Way, WA 98003 Federal Way, WA 98003 Federal Way, WA 98003 PARCEL #0818500070 PARCEL #0821049058 PARCEL #2413300060 Evelyn & Ralph Dunbar Boys and Girls Club Vincent Thanh Pham 13533 W Springdale Dr 603 Stewart Street #300 505 S 3101" PI Sun City West, AZ 85375 Seattle, WA 98101 Federal Way, WA 98003 PARCEL #0818500080 PARCEL #0821049095 PARCEL #2413300070 Patricia Hairston Ronald Samek Jon K Field 829 S 310t" Pl 30807 8t" Ave S 511 S 310t" PI Federal Way, WA 98003 Federal Way, WA 98003 Federal Way, WA 98003 PARCEL #0818500550 PARCEL #0821049105 PARCEL #2413300080 Peter Lamb & Bang Tuyen Harold Hartman Ernest & Henie Campany Ngu 30855 81" Ave S 517 S 3101" Pi 834 S 3101" PI Federal Way, WA 98003 Federal Way, WA 98003 Federal Way, WA 98003 PARCEL #0821049119 PARCEL #2413300090 PARCEL #0818500560 Boys and Girls Club Janice Bentley Renato Fajardo & Natividad 603 Stewart Street #300 30940 5" PI S 826 S 3101" PI Seattle, WA 98003 Federal Way, WA 98003 Federal Way, WA 98003 PARCEL #0821049128 PARCEL #2413300100 PARCEL #0818500570 Lakehaven Utility District Pascal Gene Hite Sherman Hu PO Box 4249 30936 5t" PI S 824 S 310t" PI Federal Way, WA 98003 Federal Way, WA 98003 Federal Way, WA 98003 PARCEL #0821049187 PARCEL #2413300110 PARCEL #0818500580 Norman & Nancy Johnson Ellen Rassilyer R Rengav Investments PO Box 1206 30932 5t" PI S 236 E Welcher Rd Tubac, AZ 85646 Federal Way, WA 98003 Coupeville, WA 98239 PARCEL #0821049205 PARCEL #2413300120 PARCEL #0818500590 Michael Gabert Bruce & Andrea Girvin Genadiy Beghdasarov & 31011 81" Ave S 30926 5t" PI S Svetlana Baghdasarova Federal Way, WA 98003 Federal Way, WA 98003 814S310t"PL Federal Way, WA 98003 PARCEL #0821049207 PARCEL #2413300130 Norris Homes Inc Kim Young Jin & Young Ja PARCEL #0818500600 2053 Faben Dr 30920 5t" PI S Margaret Gbekoyi & Mercer Island, WA 98040 Federal Way, WA 98003 Adedoyin 806 S 3101" PI PARCEL #0821049268 PARCEL #2413300140 Federal Way, WA 98003 Boys and Girls Club William & Toni Cassman 603 Stewart Street #300 30914 51" PI S Seattle, WA 98101 Federal Way, WA 98003 PARCEL #2413300150 PARCEL*2413300920 PARCEL #9315000100 Richard & Theresa Elofson Verna Wright -Stone David Hanson & Kimbra 30908 51" PI South 29401 Military Rd S #28 Bradford Federal Way, WA 98003 Federal Way, WA 98003 811 S 309t" St Federal Way, WA 98003 PARCEL #2413300160 PARCEL #2413300930 Jesse Renard James & Marie Chapman PARCEL *9315000110 30904 5t" PI S 30917 51" PI S Jackie Leon Mangrum Federal Way, WA 98003 Federal Way, WA 98003 30904 8t" Ave S Federal Way, WA 98003 PARCEL #2413300170 PARCEL #2413300940 Craig Hone James & Wanda Agostino PARCEL *9315000120 30900 5t" PI S 30923 5t" PI S Gary Larson Federal Way, WA 98003 Federal Way, WA 98003 804 S 309t" PI Federal Way, WA 98003 PARCEL #2413300180 PARCEL #2413300950 Jennifer Reid John & Sandra Merritt PARCEL #9315000130 438 S 309" St 30929 51" PI S Warren & Lolinda Tobin Federal Way, WA 98003 Federal Way, WA 98003 812 S 309t" PI Federal Way, WA 98003 PARCEL #2413300190 PARCEL #2413300960 David & Nancy Schneider Elizabeth McGhee PARCEL #9315000140 434 S 309t" St 30935 51" PI S Mark Wilhelm & S M Truste Federal Way, WA 98003 Federal Way, WA 98003 PO Box 4372 Federal Way, WA 98063 PARCEL #2413300200 PARCEL #2413300970 Victor Lucas Nancy Holihan PARCEL #9315000150 428 S 309" St 510 S 3101" PI John & Madeleine OHalloran Federal Way, WA 98003 Federal Way, WA 98003 824 S 3091" PI Federal Way, WA 98003 PARCEL #2413300240 PARCEL #2413300980 Stephanie & Brian Howe Margaret Taylor PARCEL #9315000160 431 S 308t" St 504 S 310t" Pl Pasquale Palermo Federal Way, WA 98003 Federal Way, WA 98003 15017 291" Ave S SeaTac, WA 98188 PARCEL #2413300250 PARCEL #2413301000 Jeffrey Walker Phyllis & Walter Hanson PARCEL #9315000170 437 S 308t" St 507 S 309t" Ct Craig Vern Dahl Federal Way, WA 98003 Federal Way, WA 98003 811 S 3091" PI Federal Way, WA 98023 PARCEL #2413300260 PARCEL #2413301010 Kennith Bredeson Wesley Soper PARCEL #9315000180 443 S 3081" St 511 3091" Ct S Margaret Igbekoyi Federal Way, WA 98003 Federal Way, WA 98003 805 S 309t" Pl Federal Way, WA 98003 PARCEL #2413300270 PARCEL #2413301020 James Yarno & Mau Arnold Lutovsky. Robertson 510 S 309t" Ct 447 S 308t" St Federal Way, WA 98003 Federal Way, WA 98003 PARCEL #9315000050 PARCEL #2413300910 Mark & Sharon Wilhelm Nguyen Thinh Van PO Box 4372 c/o Gam Thi Pham Federal Way, WA 98063 427 S 309t" St Federal Way, WA 98003 SERA Agency Labels for AT&T @ BUENA (WA931) File #07-103419-00-UP 31001 8th Ave S DEPT OF ECOLOGY ENVIRONMENTAL REVIEW SEC PO BOX 47703 OLYMPIA WA 98504-7703 Doc. I.D. 4ik o. Fed40':t�� eral Way DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES 33325 8th Avenue South PO Box 9718 Federal Way WA 98063-9718 253-835-7000; Fax 253-835-2609 www.cifyoffederalway.com DECLARATION OF DISTRIBUTION I, N fqc'J:J%A!,g hereby declare, under penalty of perjury of the laws of the State of Washington, that a: ❑ Notice of Land Use Application/Action ❑ Notice of Determination of Significance (DS) and Scoping Notice ❑ Notice of Environmental Determination of Nonsignificance (SEPA, DNS) ❑ Notice of Mitigated Environmental Determination of Nonsignificance (SEPA, MDNS) Notice of Land Use Application & Anticipated DNS/MDNS ❑ FWCC Interpretation ❑ Other ❑ Land Use Decision Letter ❑ Notice of Public Hearing before the Hearing Examiner ❑ Notice of Planning Commission Public Hearing ❑ Notice of LUTC/CC Pubiic Hearing ❑ Notice of Application for Shoreline Management Permit ❑ Shoreline Management Permit ❑ Adoption of Existing Environmental Document was ❑ mailed ❑ faxed ❑ e-mailed and/or osted to or at each of the attached addresses on 2007. Project Name FileNumber(s) l9-V? 0"7-10-54?_0-Sc_ Signature Date -7— 7--7- 207 K:\CD Administration Files\Declaration of Distribution.doc/Last printed 1 /2/2007 2:25:00 PM Posting Sites: --3 1 O o 1 2 ' A- 1, Federal Way City Hall — 33325 8`" Avenue Federal Way Regional Library — 34200 1" Way South Federal Way 320'h Branch Library — 848 South 320`h Street i' CITY OF Federal allay NOTICE OF LAND USE APPLICATION AND OPTIONAL DETERMINATION OF NONSIGNIFICANCE (DNS) Project Name: AT&T @ Buena (WA931) Project Description: This proposal is to add up to 12 panel antennas to support"The New AT&T" wireless network (formerly Cingular Wireless). The antennas will be located just below the rim of the water tower, which is about 81 feet above the ground, and they will be painted to match. The antennas measure approximately 6' 8" x 10" x 5". Associated transmission equipment will be housed in a 209 square -foot shed to the east of the tower. Applicant: The New AT&T; PO Box 97061; Redmond, WA 98073 Agent: Katie Johnson c/o Realcom Associates; 14432 SE Eastgate Way #260; Bellevue, WA 98007 Owner: Lakehaven Utility District; PO Box 4249; Federal Way, WA 98063 Project Location: 31001 8"' Avenue South Date Application Received: June 25, 2007 Date Determined Complete: July 23, 2007 Date of Notice of Application: July 28, 2007 Comment Due Date: August 13, 2007 (5:00 p.m.) SEPA File #: 07-103420-SE Permits Required: Process III Approval (File #07-103419-00-UP) Relevant Environmental Documents Are Available at the Address Below: X Yes _ No Optional Environmental Determination: Based upon review of a completed environmental checklist and other information on file with the City, it is anticipated that a Determination of Nonsignificance (DNS) will be issued for the proposed project. The optional DNS process in WAC 197-11-355 is being used. It is likely that the City of Federal Way will determine that the project will not have a probable significant adverse impact on the environment and an Environmental Impact Statement (EIS) will not be required under RCW 43.21C.030(2)(c). Existing Environmental Document(s): SEPA Checklist Integrated Comment Period: Consistent with the provisions of WAC 197-11-355, a single integrated comment period will be utilized to obtain comments on the Notice of Land Use Application and Notice of HcNo 07-103419 Doc. 1.D.41556 Optional Determination of Nonsignificance. This may be the only opportunity to comment on the environmental impacts of the proposal. Any person may submit written comments on the land use application or the environmental impacts of the proposal to the Director of Community Development Services by 5:00 p.m. on August 13, 2007.Only persons who submit written comments to the Director, or specifically request a copy of the decision, may appeal the Process IlI decision. However, any interested party may appeal the environmental threshold determination. Details of appeal procedures for the requested land use decision will be included with the written decision. Issuance of Final Environmental Determination: The final DNS may be issued without a second comment period, unless timely comments identify probable significant adverse impacts that were not considered by the Notice of Optional DNS. A copy of the DNS may be obtained upon request. Development Regulations to Be Used for Project Review Known at this Time: Federal Way City Code (FWCC) Chapters 18, 21, and 22 Consistency with Applicable City Plans and Regulations: Development of the site is subject to all applicable City codes and "regulations, including the FWCC chapters pertaining to zoning, environmental protection, landscaping, community design guidelines, environmental protection, and planning and development. The official project file is available for public review at the Department of Community Development Services, 33325 80' Avenue South. Comments may be mailed to PO Box 9718, Federal Way, WA 98063. City Staff Contact: Andy Bergsagel, Associate Planner Phone: 253-835-2644 Doc. I.D. 41556 File No. 07-103419 t�WA7FW Federal Way Amateur Radio Club A non profit Washington Corporation - federal ID 91-1935165 ire°rRad'¢C BY COMMl1NITYDEVEL DEVELOPMENT August 8, 2007 AUG o 9 2007 Andy Bergsagel, Associate Planner City of Federal Way P.O. Box 9718 2007-2008 Federal Way, WA 98063 OFFICERS & TRUSTEES RE: AT&T @Buena (WA931) project -Notice of Land Use Application and Optional PRESIDENT Determination of Nonsignificance. STEVE HATCH, WA7DAD SEPA File # 07-103420-SE VICE-PRESIDENT DANIEL STEVENS, KL7WM Process III Approval File #07-103419-00-UP SECRETARY Dear Mr. Bergsagel, JOHN HOLMQUIST, W7WAY AT&T is proposing to construct a new Personal Wireless Service Facility (PWSF) at TREASURER MIKE McCoy,N7VWD Lakehaven Utility District's Tanks 1 and 4 site located at 31001 8th Avenue South in Federal Way. The Federal Way Amateur Radio Club (FWARC) operates two radio PAST PRESIDENT repeaters systems from this site. The repeaters are used to support Amateur Radio GARY BRYAN, KG7KU communications by FCC licensed Amateur Radio operators. These radio repeaters are also used to support emergency radio communications. Agencies and TRUSTEES organizations served include the City of Federal Way, South King County Fire and STEVE HATCH, WA7DAD Rescue, and Lakehaven Utility District. It is critical that these systems remain free DANIEL STEVENS, KL7WM from interference. JOHN HOLMQUIST, W7WAY Federal Way City Code 22-972 (b) requires the applicant (AT&T) to not cause MIKE McCoy, N7VWD localized interference with the reception of area television or radio broadcasts or the functioning of other electronic devices. The FWARC is happy to see AT&T at this DANCAMP, KK7Uz site provided they do not interfere with our equipment and our ability to receive weak and/or distant radio signals. Remaining free from radio interference is critical GREG BEECK, KD711Q to our ability to perform our vital role to the community. GARY BRYAN, KG7KU Our equipment currently transmits on 147.04 and 442.95 MHz at power levels of over 100 watts. We receive on 147.64 and 447.95 MHz. We are currently not experiencing any interference issues. Please recognize that Lakehaven also operates radio equipment from this site. Thank you for your consideration and support. Sincerely, Steven Hatch Dav id Swartz c� President Repeater Operations '255 -92q- %L91 Post Office Box 23415 Federal Way, Washington 98093 Email: wa7fw@fwarc.org Internet: www.fwarc.org 10-1 41k CIT F 4� Federal Way DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES 33325 8t" Avenue South PO Box 9718 Federal Way WA 98063-9718 253-835-7000; Fax 253-835-2609 www.cityoffederalway.com DECLARATION OF DISTRIBUTION l hereby declare, under penalty of perjury of the laws of the State of Washington, that OT ❑ Notice of Land Use Application/Action ❑ Land Use Decision Letter ❑ Notice of Determination of Significance (DS) and Scoping Notice ❑ Notice of Environmental Determination of Nonsignificance (SEPA,, DNS) ❑ Notice of Mitigated Environmental - Determination of Nonsignificance (SEPA, MDNS) Notice of Land Use Application & Anticipated DNS/MDNS ❑ FWCC Interpretation ❑ Other ❑ Notice of Public Hearing before the Hearing Examiner ❑ Notice of Planning Commission Public Hearing ❑ Notice 'of LUTC/CC Public Hearing ❑ Notice of Application for -Shoreline Management Permit ❑ Shoreline Management Permit ❑ Adoption of Existing Environmental Document was ❑ mailed ❑ faxed k-mailed and/or ❑ posted to or at each of the attached addresses on 2007. Project Name File Number(s) SignatureIZZ f f Date 2 AZ�7 K:\CD Administralion Files\Declaration of Dislribulion,doc/Losl printed 1 /18/2007 4:06:00 PM Page 1 of 2 Tina Piety - RE: Legal Notice From: "Orr, Ellen -Tacoma" <Ellen.Orr@thenewstribune.com> To: 'Tina Piety" <Tina. Piety@cityoffederalway.com > Date: 7/31/2007 2:46 PM Subject: RE: Legal Notice Hi, Tina, We'll send out an affidavit. Thank you, Ellen Orr Legal/Obituary Representative The News Tribune 1950 S. State St. Tacoma, WA 98405 PH; 253-597-8605 FAX: 253-597-8473 EMAIL: ellen.orrathenewstribune.com. OBIT EMAIL: obitsQthenewstribune..com LEGAL EMAIL: legals@thenewstribune.com From: Tina Piety [mailto:Tina.Piety@cityoffederalway.com] Sent: Tuesday, July 31, 2007 2:44 PM To: Orr, Ellen - Tacoma Subject: RE: Legal Notice Hi Ellen, Thank you for the information. Yes, I do need an affidavit of publication. Thank you, Tina >>> "Orr, Ellen -Tacoma" <Ellen.Orr@thenewstribune.com> 7/31/2007 2:41 PM >>> Hi, Tina, I have legal scheduled to publish Thursday, August 2, 2007. The total cost came to $442.86. Did you need an affidavit of publication? If so, please let me know no later than 10:00 a.m.. Wednesday, August 1, 2007. The charge is $9.55. Thank you, Ellen Orr Legal/Obituary Representative The News Tribune 1950 S. State St. Tacoma, WA 98405 PH; 253-597-8605 FAX: 253-597-8473 EMAIL: el_len.orr@thenewstri.bune.com OBIT EMAIL: a_bits@th_enewstribune com LEGAL EMAIL: legals@thenewstribune.com From: Tina Piety [mailto:Tina.Piety@cityoffederalway.com] file://CADocuments and Settings\Default\Local Settings\Temp\XPgrpwise\46AF4B29CHPOCity H... 8/l/2007 Page 2 of 2 Posted At: Tuesday, July 31, 2007 iu:57 AM Posted To: Obits Legal Conversation: Legal Notice Subject: Legal Notice EO PRINTED/REPLIED Hello, Please publish the attached legal notice in The News Tribunes' Thursday's (8/2/2007) issue. It is my understanding that the deadline for the next day was 10:00 a.m. (which I just found out), but if it is at all possible, please publish it in tomorrow's News Tribune. Please furnish an affidavit of publishing. Please acknowledge receipt of this email and let me know when the legal notice will appear. Please send the invoice the City of Federal Way to my attention at the following address. Thank you, E. Tina Piety, Administrative Assistant City of Federal Way PO Box 9718 Federal Way, WA 98063-9718 253-835-2601, fax 253-835-2609 file://C:\Documents and Settings\Default\Local Settings\Temp\XPgrpwise\46AF4B29CHPOCity H... 8/1/2007 CITY OF Federal Way NOTICE OF LAND USE APPLICATION AND OPTIONAL DETERMINATION OF NONSIGNIFICANCE (DNS) Project Name: AT&T @ Buena (WA931) Project Description: This proposal is to add up to 12 panel antennas to support "The New AT&T" wireless network (formerly Cingular Wireless). The antennas will be located just below the rim of the water tower, which is about 81 feet above the ground, and they will be painted to match. The antennas measure approximately 6'8" x 10" x 5". Associated transmission equipment will be housed in a 209 square -foot shed to the east of the tower. Applicant: The New AT&T; PO Box 97061; Redmond, WA 98073 Agent: Katie Johnson c/o Realcom Associates; 14432 SE Eastgate Way #260; Bellevue, WA 98007 Owner: Lakehaven Utility District; PO Box 4249; Federal Way, WA 98063 Project Location: 31001 80' Avenue South Date Application Received: June 25, 2007 Date Determined Complete: July 23, 2007 Date of Notice of Application: July 28, 2007 Comment Due Date: August 13, 2007 (5:00 p.m.) SEPA File #: 07-103420-SE Permits Required: Process III Approval (File #07-103419-00-UP) Relevant Environmental Documents Are Available at the Address Below: X Yes _ No Optional Environmental Determination: Based upon review of a completed environmental checklist and other information on file with the City, it is anticipated that a Determination of Nonsignificance (DNS) will be issued for the proposed project. The optional DNS process in WAC 197-11-355 is being used. It is likely that the City of Federal Way will determine that the project will not have a probable significant adverse impact on the environment and an Environmental Impact Statement (EIS) will not be required under RCW 43.21C.030(2)(c). Existing Environmental Document(s): SEPA Checklist Integrated Comment Period: Consistent with the provisions of WAC 197-11-355, a single integrated comment period will be utilized to obtain comments on the Notice of Land Use Application and Notice of File No. 07-103419 Doc LD. 41556 Optional Determination of Nonsignificance. This may be the only opportunity to comment on the environmental impacts of the proposal. Any person may submit written comments on the land use application or the environmental impacts of the proposal to the Director of Community Development Services by 5:00 p.m. on August 13, 2007. Only persons who submit written comments to the Director, or specifically request a copy of the decision, may appeal the Process III decision. However, any interested party may appeal the environmental threshold determination. Details of appeal procedures for the requested land use decision will be included with the written decision. Issuance of Final Environmental Determination: The final DNS may be issued without a second comment period, unless timely comments identify probable significant adverse impacts that were not considered by the Notice of Optional DNS. A copy of the DNS may be obtained upon request. Development Regulations to Be Used for Project Review Known at this Time: Federal Way City Code (FWCC) Chapters 18, 21, and 22 Consistency with Applicable City Plans and Regulations: Development of the site is subject to all applicable City codes and regulations, including the FWCC chapters pertaining to zoning, environmental protection, landscaping, community design guidelines, environmental protection, and planning and development. The official project file is available for public review at the Department of Community Development Services, 33325 8 h Avenue South. Comments may be mailed to PO Box 9718, Federal Way, WA 98063. City Staff Contact: Andy Bergsagel, Associate Planner Phone: 253-835-2644 Doc I D 41556 File Na 07-103419 VICINITY MAP rDua— I Saca awe S 2 Park L -Cst CD S 304t h St ~1 p1 i 71 CIO S-M8th t— aF ` w �Jlh L (fl r co EqD y jjJr In F co Wireless Provider: The New AT&T (f/k/a Cingular Wireless) Site Name: WA931--Federal Way - Buena Project Address: 30929 8th Avenue South Parcel Number: 082104-9029 Prepared by Realcom Associates RECEIVED May 10, 2007 JUN 2 5 2007 UTYB OLDFEDERAL DEPT. WAY FEDERAL WAY - R-0. R_ A SOUND PUBLISHNG NEWSPAPER Affidavit of Publication Stuart Chernis, being first duly sworn on oath, deposes and says that he is the Publisher of The Federal Way Mirror, a semi -weekly newspaper. That said newspaper is published in the English language continually as a semi -weekly newspaper in Federal Way, King County, Washington, and is now and during all of said time has been printed in an office maintained at the aforementioned place of publication of said newspaper. That the annexed is a true copy of a legal advertisement placed by City of Federal Way L-1283 as it was published in regular issues (and not in supplemental form) of said newspaper once each week for a period of one consecutive weeks), commencing on the Ath day of August 22QQ7—, and ending on the !4th day of August, 2007 both dates inclusive, and that such newspaper was regularly distributed to its readers during all of said period. That the full amount of the fee charged for the foregoing publication is the sum of 227.22 which amount has been paid in full, or billed at the legal rate according to RCW 65.16.090 Subscribed to and sworn before me this 20th day of August, 2007. Notary Public in and for the State of Washington, Residing at Federal Way •`may �`,,����i� �A i iHii������IIJ QF 1414 S. 3241h STREET, SUITE B210, fEDERAL WAY, WA 98003 M 253-925-5565 a FAX: 253-925-5750 NOTICE OF LAND USE APPLICATION AND OPTIONAL DETERMINATION OF NONSIGNIFICANCE (DNS) Project Name: AT&T ® Buena (WA931) Project Description: This proposal is to add up to 12 panel antennas to support "The New AT&T" wireless network (formerly Cingular Wirelessj. The antennas will be located just below the rim of the water tower, which is about 81 feet above the ground, and they will be painted to match. The antennas measure approximately 6'8" x 10" x 5". Associated transmission equipment will be housed in a 209 square -foot shed to the east of the tower. Applicant. The New AT&T; PO Box 97061; Redmond, WA 98073 Agent: Katie Johnson c/o Realcom Associ- ates; 14432 SE Eastgate Way #260; Bel- levue, WA 98007 Owner: Lakehaven Utility District; PO Box 4249; Federal Way, WA 98063 Project Location: 31001 8th Avenue South Date Application Received: June 25, 2007 Date Determined Complete: July 23, 2007 Date of Notice of Application: July 28, 2007 Comment Due Date: August 13, 2007 (5:00 P.M.) SEPA File #: 07-103420-SE Permits Required- Process III Approval (File "07- 034+9-90-UPi Relevant Environmental Documents Are Available at the Address Below: X Yes No Optional Environmental Determination: Based upon review of a completed environ- mental checklist and other information on file with the City, it is anticipated that a Deter- mination of Nonsignificance (DNS)) will be issued for the proposed project. The optional DNS process in WAC 197-11-356 is being used. It is likely that the City of Federal Way will determine that the project will not have a probable significant adverse impact on the environment and an Environmental impact Statement (EIS) will not be required under RCW 43.21 C.030(2)(c). Existing Environmental Document(s): SEPA Checklist Integrated Comment Period: Consistent with the provisions of WAC 197-11ti355, a single Integrated comment period will be utilized to obtain comments on the Notice of Land Use Application and Notice of Optional Determi- nation of Nonsigniticance. This may be the only opportunity to comment on the environ- mental impacts of the proposal. Any person may submit written comments. on the land use application or the environmental Impacts of the proposal to the Director of Community Development Services by 5:00 p.m. on August 13, 2007-.Only persons who submit written comments to the Director, or specifically request a copy of the decision, may appeal the Process III decision. How- ever, any interested party may appeal the en• vironmental threshold determination. Details of appeal procedures for the requested land use decision will be included with the written decision. Issuance of Final Environmental Determina- tion. The final DNS may be issued without a second comment period, unless timely com- ments identify probable significant adverse impacts that were not considered by the Notice of Optional DNS. A copy of the DNS may be obtained upon request. Development Regulations to Se Used tar Protect Review Known at this Time: Federal Way Oity Code (FWCC) Chapters 18, 21liod, Consistency with Applicable City Plans and Regulations: Development of the site is sub- ject to all applicable City codes and ragula- iions, inctuding the FWCC chapters pertain- ing to zoning, environmental protection, landscaping, community design guidelines, environmental protection. and planning and development. The official project file is available for public review at the Department of Community Development Services. 33325 8th Avenue South. Comments may be mailed to PO Box.": 9718, Federal Way, WA 98063. i City Staff Contact. Andy Bergsagel, Assock , ate Planner Phone., 253-835-2644 FWM 1283 Date of Publication: August 4, 2007 PACIFIC NORTHWEST TITLE COMPANY OF WASHINGTON, INC. 215 Columbia Street Seattle, Washington 98104-1511 Senior Title Officer, Mike Sharkey (mikesharkey@pnwt.com) Title Officer, Curtis Goodman (curtisgoodman@pnwt.com) Assistant Title Officer, Charlie Bell (charliebell@pnwt.com) Unit No. 12 FAX No. (206)343-1330 Telephone Number (206)343-1327 RealCom Associates, LLC 14432 SE Eastgate Way, Suite 260 Title Order No.: 650372 Bellevue, WA 98007 Attention: Katie Johnson Your Ref.: Federal Way Buena A. L. T. A. COMMITMENT SCHEDULE A Effective Date: May 7, 2007, at 8:00 a.m. 1. Policy(ies) to be issued: As on Schedule A, page 2, attached. 2. The Estate or interest in the land described herein and which is covered by this commitment is fee simple. 3. The estate or interest referred to herein is at Date of Commitment vested in: LAKEHAVEN UTILITY DISTRICT, successor in interest to KING COUNTY WATER DISTRICT NO. 100, a municipal corporation, as to Parcel A and HAROLD HARTMAN and COLLEEN HARTMAN, husband and wife, as to Parcel B 4. The land referred to in this commitment is situated in the State of Washington, and described as follows: As on Schedule A, page 3, attached. JUG[ 2 5 200 CiTYNC DEPT. �L WAY A.L.T.A. COMMITMENT SCHEDULE A Page 2 Policy(ies) to be issued: A.ALTA Owner's Policy Amount Standard (X) Extended ( ) Premium Tax (8.9%) Proposed Insured: TO FOLLOW Order No. 650372 TO BE AGREED UPON NOTE: IF EXTENDED COVERAGE FOR OWNERS OR LENDERS WILL BE REQUIRED FOR A PENDING TRANSACTION, PLEASE NOTIFY US AT LEAST ONE WEEK PRIOR TO CLOSING SO THAT WE MAY INSPECT THE PREMISES. B.WORK CHARGE Amount $ 350.00 Tax (8.9%) $ 31.15 (Schedule A, continued) Order No. 650372 A.L.T.A. COMMITMENT SCHEDULE A Page 3 The land referred to in this commitment is situated in the State of Washington, and described as follows: PARCEL A: The south half of the northeast quarter of the southeast quarter of the northwest quarter of Section 8, Township 21 North, Range 4 East, W.M., in King County, Washington; EXCEPT the north half of the Southeast quarter of the northeast quarter of the southeast quarter of the northwest quarter of said Section 8; AND EXCEPT the southwest quarter of the southwest quarter of the northeast quarter of the southeast quarter of the northwest quarter of said Section 8; AND EXCEPT the east 30 feet; AND TOGETHER WITH the west 30 feet and the south 30 feet of the southwest quarter of the southwest quarter of the northeast quarter of the southeast quarter of the northwest quarter of said Section 8; AND FURTHER EXCEPTING the west 147 feet of the east 177 feet of that portion of the south half of the southeast quarter of the northeast quarter of the southeast quarter of the northwest quarter of Section 8, Township 21 North, Range 4 East, W.M., in King County, Washington, lying northerly of the south 30 feet thereof. PARCEL B: The west 120 feet of the north half of the southeast quarter of the northeast quarter of the southeast quarter of the northwest quarter of Section 8, Township 21 North, Range 4 East, W.M., in King County, Washington; EXCEPT the east 30 feet thereof conveyed to King County, Washington for road by deed recorded under Recording Number 2597904, in King County, Washington. END OF SCHEDULE A NOTE FOR INFORMATIONAL PURPOSES ONLY: The following may be used as an abbreviated legal description on the documents to be recorded, per amended RCW 65.04. Said abbreviated legal description is not a substitute for a complete legal description within the body of the document. SE NW, 08-21-04 PACIFIC NORTHWEST TITLE COMPANY OF WASHINGTON, INC. A.L.T.A COMMITMENT Schedule B Order No. 650372 I. The following are the requirements to be complied with: A. Instruments necessary to create the estate or interest to be insured must be properly executed, delivered and duly filed for record. B. Payment to or for the account of the grantors or mortgagors of the full consideration for the estate or interest to be insured. II. Schedule B of the Policy or Policies to be issued (as set forth in Schedule A) will contain exceptions to the following matters unless the same are disposed of to the satisfaction of the Company: A. Defects, liens, encumbrances, adverse claims or other matters, if any created, first appearing in the public records or attaching subsequent to the effective date hereof but prior to the date the proposed Insured acquires for value of record the estate or interest or mortgage thereon covered by this Commitment. B. GENERAL EXCEPTIONS: 1. Rights or claims of parties in possession not shown by the public records. 2. Public or private easements, or claims of easements, not shown by the public record. 3. Encroachments, overlaps, boundary line disputes, or other matters which would be disclosed by an accurate survey or inspection of the premises. 4. Any lien, or right to a lien, for services, labor or material heretofore or hereafter furnished, imposed by law and not shown by the public records, or Liens under the Workmen's Compensation Act not shown by the public records. 5. Any title or rights asserted by anyone including but not limited to persons, corporations, governments or other entities, to tide lands, or lands comprising the shores or bottoms of navigable rivers, lakes, bays, ocean or sound, or lands beyond the line of the harbor lines as established or changed by the United States Government. 6. (a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) water rights, claims or title to water. 7. Any service, installation, connection, maintenance, capacity, or construction charges for sewer, water, electricity or garbage removal. 8. General taxes not now payable or matters relating to special assessments and special levies, if any, preceding the same becoming a lien. 9. Indian tribal codes or regulations, Indian treaty or aboriginal rights, including, but not limited to, easements or equitable servitudes. C. SPECIAL EXCEPTIONS: As on Schedule B, attached. Order No. 650372 A.L.T.A. COMMITMENT SCHEDULE B Page 2 SPECIAL EXCEPTIONS: NOTE FOR INFORMATION PURPOSES ONLY: EFFECTIVE JANUARY 1, 1997, AND PURSUANT TO AMENDMENT OF WASHINGTON STATE STATUTES RELATING TO STANDARDIZATION OF RECORDED DOCUMENTS, THE FOLLOWING FORMAT AND CONTENT REQUIREMENTS MUST BE MET. FAILURE TO COMPLY MAY RESULT IN REJECTION OF THE DOCUMENT BY THE RECORDER. FORMAT: MARGINS TO BE 3" ON TOP OF FIRST PAGE, 1" ON SIDES AND BOTTOM - 1" ON TOP, SIDES AND BOTTOM OF EACH SUCCEEDING PAGE. RETURN ADDRESS IS ONLY ITEM ALLOWED WITHIN SAID 3" MARGIN. NOTHING WITHIN 1" MARGINS. FONT SIZE OF 8 POINTS OR LARGER AND PAPER SIZE OF NO MORE THAN 8 1/2" BY 14". NO ATTACHMENTS ON PAGES SUCH AS STAPLED OR TAPED NOTARY SEALS; PRESSURE SEALS MUST BE SMUDGED. INFORMATION WHICH MUST APPEAR ON THE FIRST PAGE: RETURN ADDRESS, WHICH MAY APPEAR WITHIN THE UPPER LEFT HAND 3" MARGIN. TITLE OR TITLES OF DOCUMENT. IF ASSIGNMENT OR RECONVEYANCE, REFERENCE TO RECORDING NUMBER OF SUBJECT DEED OF TRUST. NAMES OF GRANTOR(S) AND GRANTEE(S) WITH REFERENCE TO ADDITIONAL NAMES ON FOLLOWING PAGES, IF ANY. ABBREVIATED LEGAL DESCRIPTION (LOT, BLOCK, PLAT NAME, OR SECTION, TOWNSHIP, RANGE AND QUARTER QUARTER SECTION FOR UNPLATTED). ASSESSOR'S TAX PARCEL NUMBER(S). (continued) Order No. 650372 A.L.T.A. COMMITMENT SCHEDULE B Page 3 SPECIAL EXCEPTIONS (continued): 1. EASEMENT AND THE TERMS AND CONDITIONS REFERENCED THEREIN, INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING: GRANTEE• Pacific Telephone and Telegraph Company PURPOSE: Poles and wires AREA AFFECTED: The description contained therein is not sufficient to determine its exact location within the property herein described. RECORDED: May 31, 1924 RECORDING NUMBER: 1876203 2. EASEMENT AND THE TERMS AND CONDITIONS REFERENCED THEREIN, INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING: GRANTEE: Pacific Telephone and Telegraph Company, a California corporation PURPOSE: Underground conduit AREA AFFECTED: The description contained therein is not sufficient to determine its exact location within the property herein described. RECORDED: March 28, 1930 RECORDING NUMBER: 2595387 3. EASEMENT AND THE TERMS AND CONDITIONS REFERENCED THEREIN, INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING: GRANTEE: Puget Sound Power & Light Company PURPOSE: Install, maintain, replace, remove and use electric line AREA AFFECTED: The east 550 feet of the south 30 feet of Parcel A RECORDED: September 22, 1961 RECORDING NUMBER: 5332482 (continued) Order No. 650372 A.L.T.A. COMMITMENT SCHEDULE B Page 4 4. EASEMENT AND THE TERMS AND CONDITIONS REFERENCED THEREIN, INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING: GRANTEE: King County Water District No. 100, a municipal corporation of King County, State of Washington PURPOSE: Water Main AREA AFFECTED: Portion of said premises RECORDED: September 19, 1963 RECORDING NUMBER: 5639968 5. EASEMENT AND THE TERMS AND CONDITIONS REFERENCED THEREIN, INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING: PURPOSE: Road AREA AFFECTED: South 15 feet of Parcel B RECORDED: December 28, 1970 RECORDING NUMBER: 6727306 6. RESTRICTIONS CONTAINED IN INSTRUMENT, AS HERETO ATTACHED: RECORDED: October 17, 1956 RECORDING NUMBER: 4740307 7. AGREEMENT AND THE TERMS AND CONDITIONS THEREOF: By; King County Water District No. 124 and W. Bond Shippy and Hazel T. Shippy, his wife RECORDED: February 23, 1973 RECORDING NUMBER: 7302230394 REGARDING: Grantor, upon request of Grantee's, shall dedicate and deed to King County, for no additional compensation, for road purposes the following described property: The south 30.73 feet of said premises 8. STATE OF WASHINGTON SUPERSEDING CERTIFICATE OF WATER RIGHT AND THE TERMS AND CONDITIONS THEREOF: RECORDED: December 21, 2005 RECORDING NUMBER: 20051221001416 (continued) Order No. 650372 A.L.T.A. COMMITMENT SCHEDULE B Page 5 9. STATE OF WASHINGTON SUPERSEDING CERTIFICATE OF WATER RIGHT AND THE TERMS AND CONDITIONS THEREOF: RECORDED: RECORDING NUMBER: December 21, 2005 20051221001417 10. Matters disclosed on a survey recorded under Recording Number 8705089004, a copy of which is hereto attached. 11. The property herein described is carried on the tax rolls as exempt; however, it will become taxable from the date of transfer to a taxable entity. TAX ACCOUNT NUMBER: 082104-9029-01 NOTE: PLEASE CONTACT THE KING COUNTY ASSESSOR'S OFFICE AT 206-296- 5151 OR ONLINE AT "WWW.METROKC.GOV/ASSESSOR" TO VERIFY THE TAX AMOUNT DUE. AS EXEMPT TAXES ARE SUBJECT TO CHANGE WITHOUT NOTICE. 12. CONTRACT OF SALE AND THE TERMS AND CONDITIONS THEREOF: SELLER: PURCHASER: DATED: RECORDED: RECORDING NUMBER: EXCISE TAX RECEIPT NUMBER: Water District No. 124, King County, Washington Harold Hartman and Colleen Hartman, his wife December 2, 1980 September 24, 1981 8109240298 Not disclosed Said instrument is an exchange contract involving Parcel B and other property. 13. MEMORANDUM OF AGREEMENT: LESSOR: Lakehaven Utility District, successor in interest to Lakehaven Sewer District and Federal Way Water and Sewer District, a municipal corporation LESSEE: New Cingular Wireless PCS, LLC, a Delaware limited liability company DATED: December 19, 2005 RECORDED: June 20, 2006 RECORDING NUMBER: 20060620000677 (continued) Order No. 650372 A.L.T.A. COMMITMENT SCHEDULE B Page 6 14. Unrecorded leaseholds, if any; rights of vendors and holders of security interests on personal property installed upon said property and rights of tenants to remove trade fixtures at the expiration of the term. 15. LIEN: CLAIMED BY THE STATE OF WASHINGTON, DEPARTMENT OF AGAINST: IN AMOUNT OF: RECORDED: RECORDING NUMBER: Social and Health Services Harold T. Hartman $3,590.07 (and interest) October 22, 1998 9810220322 NOTE: The lien of said matter depends upon the identity of the debtor with Harold Hartman. 16. Until the amount of the policy to be issued is provided to us, and entered on the commitment as the amount of the policy to be issued, it is agreed by every person relying on this commitment that we will not be required to approve any policy amount over $100,000, and our total liability under this commitment shall not exceed that amount. 17. Payment of Real Estate Excise Tax, if required. The property described herein is situated within the boundaries of local taxing authority of City of Federal Way. Present Rate of Real Estate Excise Tax as of the date herein is 1.780. (continued) Order No. 650372 A.L.T.A. COMMITMENT SCHEDULE B Page 7 NOTE 1: SPECIAL TAXES AND CHARGES, PAID IN FULL: YEAR: TAX ACCOUNT NUMBER: SPECIAL DISTRICT: TOTAL BILLED: 2007 082104-9029-01 AMOUNT BILLED $10.56 $3.54 $14.10 PAID: $14.10 END OF SCHEDULE B Title to this property was examined by: David Clasen Any inquiries should be directed to one of the title officers set forth in Schedule A. DO/6245098/8109240300 Portion of the northwest 1/ 8-21-4 t 90 .-e 102 le-4 PACIFIC NORTHWEST TITLE Company of Washington, Inc. a KGSPBN0064 -.1 SM115OT95 a LOT 2 9 iryMiC� `ITT 1© 0 Li N Order No. 650372 IMPORTANT: This is not a Plat of Survey. It is furnished as a convenience to locate the land indicated hereon with reference to streets and other land. No liability is assumed by reason of reliance hereon. AT&T @ Buena CITY OF < Ave South 31001 8th Federal Way Parcel No. 082104-9029 J i LD co m - S 309 ST—'i S 309 ST -,,z- Cn d- s"- Site co S 309 PL El S 310 PL= > , \S 312 ST rn rn ... �• i File 07-103419-UP / 07-103420-SE p 500 Fee[ N MASTER LAND USE APPLICATION DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES 33325 8m Avenue South CITY OF ��� ]RECEIVES PO Box 9718 Federal Way JUN 2 6 Zook Federal Way WA 98063-9718 253 835-2607; Fax 253-835-2609 o . to 3 420 - VU St/ Y OF FEDERAL WAY www.cityoffederalway.com ILDING DEPT, APPLICATION No(s) 7`k Ok -Date k-2S-07 Project Name AT&T @ Federal Way - Buena (WA931) I T G� t3 u E a(V,/ A 9 3 ( } ;31001 Property Address/Location 3$92,9-Eighth Avenue South Parcel Number(s) 082104-9029 Project Description Collocation of wireless antennas on the existing water tank. Associated transmission equipment will be located in a new CMU shed. PLEASE PRINT Type of Permit Required _ Annexation Binding Site Plan _ Boundary Line Adjustment Comp Plan/Rezone _ Land Surface Modification Lot Line Elimination _ Preapplication Conference _ Process I (Directors Approval) Process II (Site Plan Review) X Process III (Project Approval) _ Process IV (Hearing Examiner's Decision) Process V (Quasi -Judicial Rezone) Process VI SEPA Only X SEPA w/Project Shoreline: Variance/Conditional Use Short Subdivision _ Subdivision Variance: Commercial/Residential Required Information RS 7.2 Zoning Designation SFHD Comprehensive Plan Designation N/A Value of Existing Improvements $60 000 Value of Proposed Improvements International Building Code (IBC): Unoccupied Occupancy Type Telecommunications Construction Type Applicant Name: The New AT&T (f/k/a Cingular Wireless) Address: PO Box 97061 City/State: Remond, WA 98073--7061 Phone: See Agent Information Below Email: See Agent Information Below Signature: See Agent Information Below Agent (if different than Applicant) Name: Katie Johnson c/o Realcom Associates Address: 14432.&E Eastgate Way, #260 City/State: Bellevue, WA 98007 Phone: 206-604-7760 Email: kjohnson ai 7realcomassoc.com Signature: Owner Name: Lakehaven Utility District Address: PO Box 4249 City/State: Federal Way, WA 98063 Phone: 253-946-5446 (Linda Kochmar) Email: LKochmar@lakehaven.org Signature: SLf akw"ickwA Bulletin #003 —August 18, 2004 1 of 1 k:\\Handouts\\Master Land Use Application SITE LEASE FOR MOMMMCAUONS FACELMFS THIS lease (- �k betwe� ,t,AI SBAv �"�, a this ,�aay of�� � ("016clive Date") by and Federal Way Water and Sewer ric4 a nu ipalmccor in Inle rest to Lalco wcn Sewer �� a �rnicipal vorpn�#ion, having $ D"stixct and 4249, Federal Way, Wa$ n, 98063-4249 mailingaddrm of Pt3 Bnx Wireless PCS, LI,C, a Delaware limited liab ' Ow inafter r� Twred to as "Les and Nov C*gtriar Houie�raord, Nam, Gcargia 3007I as ""�gerrtY �, �as,, add+ess of 6tQ� Atlantic H MGROUND Lessor owns that Certain plot, Parcel or tract of Saud P Weges (`�") together with all rights and ari8�g cumcctiau therewi located at 30929 8" Avenue South, Federal Way, Washington 98003, in the C mty of King, State of Washington (��y �Y is kcarporate . herein at Exhibit A. Lessee � ' A legal won of the with. its &derala dew #o use a portion of the Property in , on Peron of the y � � but business. Lessor desues to great to .Lessee the r to use a Property rclance ,� � �#. I. LEASE OF P,�+II,S�_ Lessor ieases to Lessee PMtions of the Property canMtMg of (a) a roomIcabineVground slrace of approxmmtely 32.0 Re and (b) area easements as arc n space om the stxucttrr+e together with such Exhibit A 1 and A 2 ( itecovdy, the initial installation as gybed on sttaGberl Lessee may use the Premim for the hmmis$ion and the installaiaorr, Construction, � u �� lemof mimi moth& Sig�g and replaceanemt of its communicaticm taffy and "r'' o�'al, modn�c on �/or � n'vements, which may include a suitable cables, access and sheitem or cabinets and fencing smart , associated antennas, cgWpnmt the Prentiseg#collectively the "Con F� � � � � s� �'e use of survey and review title oQ the �Y")9 such tree may inelrxde the right to test, agreethat any portion of the ° (collectively, the "Pctmi#ted Use"), Lesser and Lessee A 2 will not be deed to wit mmwAfton Fam a may be dessanbed on I?xhrbi# A 1 and Lessee's F� Use. If Bxlul* A 1 and A 2 includes nfe� drawings of the initial msMilation of the COMMUnication Facility, Lessor's execution Agreement will signify Lessors OPProval of Fx}Oit A 1 and A 2. Lessee has the right to make ftTefty �VementS, alterations or additions appropriate fir Lessee's use including the right t e modify, fY, =PPS#, uPgmk expand the equipment, mc"'se the mix of � or rel during the �the �on Facility (`lessee's Changes') within the Pnwfises at am went with Lessors Y time withheld or which appr wall not be `ela3'� t that Lessor approval shall not be rrgwd for routine modification repairs, of the rvAla�meut of the C nio�on Facility, or any Lessee agrees that if � shelter or items housed ther m. . excess o ��Lessee's increase the number of a uteunas an,d related in Shown, the monthly Rent shall automaticauy increase by an a wIlut MORdar W"Jess — 3DM a Avenue South (WA 931) Page 1 judgment, then Lessee n28Y tmminate this Agreement with no further li" or erMnt Lessee elects to te�#etY Penalty in the exercise of the relocation cg�on, and aforesaid,swh em LesLessor sees ave�a��a��w its deemed null and vaid shall be n I esaee shall Ilot be required to cond'ct such. relocation in a any mat�eaicause ,ai deterioration or diction of such � which would ouch �m Any relocativn of Levee b �� or which would cause anginter-option of y Lessor shall be made and comupleted, if reasanab jy P> an a wed so as not to � Lessees business operations coa&cted an the (d) 'The MIOM ion of Lessee's Tel scab n Facility to the Altemate 'lot cause the Fee under der this Agre=mt to be inn-sed. �� shall (e) The reek cation Of %esW's TelmOmmulication Facility to the Alternate Preis shall be a0i=Pfished by Lessee at Lessee's sole expense. (fl Upon the relocadon of Lessee's TelecOMMIMication. Facility from the premiscs to the Altes� Premises, ell maces in this Agre memt to the Premisea shall be deemed to be refewces to the Alternate Premises. Following such relocation, Lessee AgreemXqIM ent. Ong the Ah=ate Prerai� which shall 'then replace Exhr'hit ��{ c� LESSOR LESSEE: LakeIMM Utility Distm�, successor in interest to New Cmgular WIrelms PCS, LLC, Lakehavea Sewer District and Federal Way Dilater a I]�elaware limited limy y and mower District, s =micWW motion agar wrreress_ 30M dhAvenue (WA sat) By: Print Name: Its: Executive Director of Network Serviees Bade: c { ... iw"FFT- Pape 12 AT Portion of the northwest 4 8-21-4 f •:� v1� yy KCSP BS0064 - o B2111S0796 L07 gOT P� .r i+3°°C .a]e s6 aio.7. pr) M nn ■- jr 'e > S L am 4 h r �� IZ r I k6AF ; r r�pa f 16 PACIFIC NORTHWEST TITLE_ Order No. 650372 Company of Washington, Inc. IMPORTANT: This is not a Plat of Survey. It is furnished as a convenience to locate the land indicated hereon with reference to streets and other land. No liability is assumed by reason of reliance hereon. RECEIVED JUN 2 5 2007 CITY OF FEDERAL WAY UIJIMNO OEPT, t A�k CITY Way July 27, 2007 Katie Johnson Realcom Associates 14432 Eastgate Street, Suite 260 Bellevue, WA 98007 CITY HALLFILE 33325 8th Avenue South Mailing Address: PO Box 9718 Federal Way, WA 98063-9718 (253) 835-7000 www.cityoffederalway.com RE: File #07-103419-00-UP; COMPLETE APPLICATION AT&T @ Buena (WA931), 31001 81' Avenue South, Federal Way Dear Ms. Johnson: On June 25, 2007, the City of Federal Way received the above -referenced Process III application with a SEPA checklist. Upon receipt of an application the City has 28 days to determine whether all required information and documentation required for a complete application pursuant to Federal Way City Code (FWCC) Section 22-33 has been submitted. As of July 23, 2007, we have determined that the application is complete. Therefore, we have prepared a combined Notice of Application/Optional (Anticipated) Determination of Nonsignificance (DNS), which is enclosed. Within 120 days of the determination of complete application, the Director of Community Development Serviced will endeavor to issue a decision on the Process III project_ The 120-day clock is stopped any period during which the applicant has been requested by the City to correct plans, perform required studies, or provide additional information. If you have any questions regarding this letter, please contact the at andy.bergsagel@cityoffederalway.com, or 253-835-2644. Sincerely, BOA -� Ay Bergsage Andy Ber sa el Associate Planner enc: Notice of Land Use Application/Notice of Optional Determination of Nonsignificance c: Stan French, Lakehaven Utility District, PO Box 4249, Federal Way, WA 98063 Linda Kochmar, Lakehaven Utility District, PO Box 4249, Federal Way, WA 98063 Ann Dower, Engineering Plans Reviewer Scott Sproul, Acting Assistant Building Official Chris Ingham, South King Fire File No 07-103419-00-UP Doc ID 41489 _tom S- tz pie , 1A No. in 21 r. '+V ::� - •.� � .. a 7� � � PARCEL MAP i z 3wutrw Z41330u26D 2413300250 0821049095 93is� 0821649/758 00 24133780 2413300170 2413300190 733002t10 9315 33MY"3T 2413300160 D821049268 0821049119 2413300750 2413300920 2473300930 2113300140 H315L 113307020 H d 24133DO130 te 93150 0@2`029 704910� 241330094D L� 24733D012D 2413300OW 0821049128 I s �13301000 2413300110 Federal Way 937 504 241330D960 2413300100 2413300970 N*- 0827049205 0818500, ay'$`016 2473300090 061 2413300080 2413300070 0827049767 082704920'7 733OW60 081f 08185000 2413300040 2413300050 2413300030 0821049045 081850 081 aJ 24133WO20 0821049190 0827049238 0921049030 Wireless Provider: Site Name: Project Address: Parcel Number: Prepared by Realcom Associates The New AT&T (f/k/a Cingular Wireless) WA931--Federal Way - Buena 30929 8th Avenue South 082104-9029 FEE ZONING MAP S 3€ 3T.H ST ISISilG+f: �'!"Ifti :1.•�= 3AwGq ye• �f Jf 3A1 Jecx,•f,•,{i Jlxgr,X 114 sxx>fc� — nr_ r m : I.1lsans o� JIM :I•tr. '�•viC•: A W f1tJ �f{ f: �y� •� C 309 1 K ST J!lip,.: Jlr` qF ]4 x• 1Mw �pxYlim j� � R S 7 RS7.2 F •, o cn .r� AfR -� � yf� �� lfflf IMd G :l•:JVrI.: :sllawr �:r r._ •:.rs• Y V� .�Sj�f•� .mlC. �]Im� —1x,a �:�iM1:a C7 L 1esp1 elx- ��r_ wr alr°�•: aa� a 111 RM r :e..ca.e �Q1r seaiR, =a•ca r.1 xs.e= 111.4 .ram a�aen V 1 11fi1 V�;xL l 'S11K IIR1 - R S 2 Illµ �,ql lT} . D= Y1� lint- I,c�Rarr �M 111:a S sas1•t- [.IY nrpefca m [-. MIN it 06� . Ir„M CpI [.t=Kl.a M*04M 1 + M9 rit S MTH PL rl Cara M a: wrlrw •— >n•�w:1 [ 1 Sµ3 t 07H I r xsx sxl JJT= wl -III �Ir�1t :cvs�cr]y y7xq � Jil .g lfR[ I nnS 7. _- L1 ill•T S 312TH ST $ 312TH ST D=Cn:_ :e:if��: y:.„ 1 a � •,c._—. .�I: ny Vi �Y C.� yy,ttfi (�•� Wireless Provider: Site Name: Project Address: Parcel Number: Prepared by Realcom Associates The New AT&T (f/k/a Cingular Wireless) WA931—Federal Way - Buena 30929 8th Avenue South 082104-9029 COMPREHENSIVE PLAN 1 L� Comprehensive Plan - Map 2 M CiLy Carder Cxxeomtn9ry3f�F�9GraBfO�V Mulls-��rr�h�y City Conlar Frwo 0 Bmrau Park Singly Famly-}qh DanFry �Ccxpnrabe Park =lll*ighbcwhmd Sumness n Singls Famiy-Mai%rn Duna'v cgsca Perk W G=muriry 3uzin&" Singly Farni.y- Pratesoonal lifts W Parks and Opon Space LOW:'J*gMly Wireless Provider: Site Name: Project Address: Parcel Number: Prepared by Realcom Associates The New AT&T (f/k/a Cingular Wireless) WA931--Federal Way - Buena 30929 8th Avenue South 082104-9029 TOPOGRAHPY MAP 247330iltWCN�' `� = �� - — 1 {._, ti1745ow 40 +Q 24?33UU26C 2473300240 4i+fU0270 h i 3 r G$2 i049P 24t3300i 43?!s£3 ]�3971 $ i • 360 J [f� L b82 Od9Il5$ 931sw. *g rr 2f733RJU2Q0 24030filfO 93i5n0UUfi{J 4 �� `.r,r'J 93tsC�00050 $3i6G40070 W� 5309'fl�•� 2R733i�U9�0 J ��r2fi3'30L / (782i0d926G 1 S 7 r 5i r S///��� W � i^ 43f500MBO o24133Di go I � ? a82ia4Si.19 � yJ ?4Y3 49fJ0 r`�+ j 082i ' 9f05 93i5GW110 93MV000090 � Cfa2Y�G49 241 kk33p70 U 1 ",4,, 30 ii33CIY030 2433r30130 ti Federal Rat f20 l9Jisa40140 kk 7 24133010f) j}j i 01(M0 24133WQ50 J 8210-19029 � � f 93950aUy� 24?33010&-L } 0r82,�90,49i2�� i 93f5iJrJDYffi 2413300990 cdj334Glfl 93154001W ! r'^) 08YB5¢06iA9 08 lFU5G0 �y I i y,r 082i049205 4$Y$Sa0S50 Ot395[ 2 w2t 3�49239 �� 3 oGt 049fBi' 83s k f C 39 Pf3saol�s�i, rF V OBZ1DR9211i o�iasaGc+2n GHi35i70380- 0821{N9277 ?4t3300Rd0� {� � i791850CAf72G 2413309030 08Y 850 r'RC 7 p81l0t9253� ?l 3D0 CkB2l4•i +f5 6818500050 fir- (!$iS3UO3 94 2 ri•334Da7U j j 482t0+i9G 08I SSWOM {i5i f35U036 ry 0fi2i0442381J t 0811049150 0$18500350 � G82��-G1-5�?�315 0� $i8 iG. 0$P1U4920� j 0811Q49i75� ��(j (}gY85C i 7d 9 MAVE ` 0821049,Y99 LB21049027 i'0818500220 VCO ntours Shown fiJ3fRq(Jd•U� ss59s00a5G �r0827049919 8G+J3d09045 55596RG0Y4 J3�U 35 8GG3l44005R %� 8589£�GO<aYU 8566000125- .A Wireless Provider: Site Name: Project Address: Parcel Number: Prepared by Realcom Associates The New AT&T (f/k/a Cingular Wireless) WA931--Federal Way - Buena 30929 8th Avenue South 082104-9029 Soo V - S 304th Pn CIA ,32 t s� Wireless Provider: Site Name: Project Address: Parcel Number: Prepared by Realcom Associates VICINITY MAP AP 2 jr; I r ' sacajawe Park 302nd -St 303 rd - S' 21 � rL n .5 CO The New AT&T (f/k/a Cingular Wireless) WA931--Federal Way - Buena 30929 8th Avenue South 082104-9029 Wireless Provider: Site Name: Project Address: Parcel Number: Prepared by Realcom Associates The New AT&T (f/k/a Cingular Wireless) WA931—Federal Way - Buena 30929 8th Avenue South 082104-9029 c'i ny'o� u . r _.� 1 F r s" RAVEN 30929 8TH AVE SOUTH FEDERAL WAY, WA 98003 WA--9 31 � PROJECT INFORMATION APPLICANT: LAND OWNER: NEW CINGULAR WIRELESS LLC LAKEHAVEN UTILITY DISTRICT 16221 NE 72nd WAY 31627 FIRST AVE SOUTH REDMOND TOWN CENTER, BUILDING #3 FEDERAL WAY, WA 98003 P,O. BOX 97061 STAN FRENCH (253) 946.5410 WATER TOWER OWNER: LAKEHAVEN UTILITY DISTRICT PROJECT ENGINEER' 31627 FIRST AVE SOUTH CORNERSTONE ENGINEERING, INC. FEDERAL WAY, WA 98063 1A2D1 NE 200TH STREET, SUITE #200 STAN FRENCH (253) 946-5410 WOODINVILLE, WA. 98072 MARK W OLSON, P.E. PROJECT CONSULTANTS: (425) 487-1732 REALCOM 3245 146TH PLACE SE, SUITE 320 BELLEVUE. WA 98007 STRUCTURAL ENGINEER: PH' (425) 2744444 FAX: (425) 274-4449 CORNERSTONE ENGINEERING, INC. 14201 NE 200TH STREET, SUITE #200 TEAM LEAD: WOODINVILLE. WA. 98072 RYAN WARD MARK W OLSON. P.E. (425) 241.2695 (425)467-1732 SITE AQUISITION JEANETTE McDONALD CODE INFORMATION: (206)714-BOOB ZONING CLASSIFICATION: IRS 7.2 ZONING AGENT: BUILDING CODE: IBC 2003 KATIE JOHNSON (206)604-7760 CONSTRUCTION TYPE TELECOMMUNICATIONS CONSTF(UCTFON COORDINATOR: KEVIN KITCH OCCUPANCY: UNOCCUPIED (425) 306-3909 JURISDICTION: FEDERAL WAY SITE MANAGER RYAN WARD PROPOSED BUILDING USE TELECOMM (425) 214-2595 517E LOCATION: ($ASE(1 ON NAO 83 PARCEL NUM$ER S . LATITUDE: 47' 19' 29-05- 0821D49029 LONGITUDE: 122' 19' 33.57 AREA ❑- PARCEL: TOP OF STRUCTURE AGL- 9W-0- 3.21 ACRES (139,927 S.F.) BASE OF STRUCTURE AMSL: 450'-0- NEW IMPERVIOUS AREA PROJECT AREA: APPROXIMENTLY 209 S.F. 209 S.F. GENERAL INFORMATION: 1. PARKING REQUIREMENTS ARE UNCHANGED. 2. TRAFFIC IS UNAFFECTED. 3. SIGNAGE IS PROPOSED. 4. NO ADDITIONAL IMPERVIOUS AREA IS PROPOSED. PROJECT DESCRIPTION: CINGULAR WIRELESS LLC. PROPOSES TO CONSTRUCT AN UNSTAFFED RADIO TEL ECOM MUNI CAT I DNS F4CI L ITY CONSI STING OF A THREE-SECTORANTENNA ARRAY MOUNTED ON AN EXISTING WATER TANK, WITH RADIO EQUIPMENT IN A PROPOSED CM SHELTER ON GRADE IN A GRAVEL PAVED AREA WITHIN AN EXISTING FENCED COMPOUND - PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS 15 PROPRIETARY By NATURE, ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CINGULAR WIRELESS, LLC. SERVICES IS STRICTLY PROHIBITED. DRAWING INDEX DWG. NO. DESCRIPTION T-1 TITLE SHEET G-1 GENERAL NOTES C-1 SITE SURVEY A-1 ARCHITECTURAL SITE PLAN A-2 ENLARGED SITE PLAN A-3 ELEVATION(S) A-3.1 ELEVATION(S) & ANTENNA DETAILS A3-2 EQUIPMENT SPECS AA CONSTRUCTION DETAILS A4.1 CONSTRUCTION DETAILS A4.2 CONSTRUCTION DETAILS A-4.3 INTERIOR ELEVATIONS A-4A CONSTRUCTION DETAILS A-5 CONSTRUCTION DETAILS A-5.1 CONSTRUCTION DETAILS A-52 CONSTRUCTION DETAILS A-6 RADIO PLAN A 7 ANTENNA SWEEP TEST & COAX COLOR CODING E-1 UTILITY PLAN & DETAILS E-2 ELECTRICITELCO DETAILS E-2.1 POWER ONE -LINE DIAGRAM E-3 SCHEMATIC GROUNDING PLAN E-3.1 GROUNDING DETAILS E-32 GROUNDING DETAILS & NOTES Q-1 QUALITY CONTROL CHECKLIST LEGAL DESCRIPTION PARCEL A: THE SOUTH HALF OF THE lion III IEAOT OUARTER OF THE SOU IMEA ST QUARTER OF THE NORTM'IEST OVARTER OF 8ECT10N 8, TOMAii[P 21 NORIIH. RANGE 4 EAST, VAUAIAEM L.ILTIIDIAN, IN XJNG COUNTY, WASHINGTON; EXCEPT THE. NORTH HALF OFTHE SOLITi7EAST O AFITER CF111E NORTHEAST QUARTER OF THE SOUTHEASY OUARTFR OF THE NoRTMYEsT QUARTER OF SAID SECTION S; AND EXCEPT THE SOUTHWEST OUARTER OF THE SOUTHWEST OUARTER OF THE NORTHEAST QUARTER OF THE SOUTHEAST QUARTER OF THE NOMM EST QUARTER OF SAID EECTIOLiAANO EXCEPT THE EAST30 FEET ANO TOGETHER WITH THE WEST 30 FEET M�r�°1F�. �'� S W OF THE SOUTWiZS'r QUARTER OF THE SOUTHW90 c2 '+ft° NORTHEAST QUARTER OF THE SOUTHEAST OUARTER OF THE NORTHWEST QUARTER OF SAID SECTION 6; n1ATTPORnW+o OT{E SOUTH HALF O147 THFEET SOUTHEAST'G RiERE 07 () THE NORTHEAST QUARTER OF THE SGUTHEAST QUARTER OF THE lJ NORTHWEST OF SECTION IL TDpniSHP 21 NORTH, RANGE 4 EAST, WILLAMETTE MERIDIAN. LYING NORTHE PLY THEREOF. Lf Y C pE �7pF�F5 R BUILDING DEP 2 0 c� J C< W w cw-�) pF1VE3Lr5TON6 1�I LGZWSi-9j,TEIlO PIIR&(.4R.1TA N000rN1II'WAVM FAIL RSW7.1rs1 WCAIL" dim GATE; 0e.10.05 DRAWN BY: A.Is CHECKED BY: aWo Sa Lcm a� v+. Dc �F VMSyk Or T o 1231t Fss'-0kA E1,v EXFIFLES t ium SITE WA931 RANEN 30929 8TH AVE SOUTH FEDERAL WAY, WA 98003 SHEET TITLE F—TITLE SHEET r SHEET NUMBER T-1 GENERAL NOTES: 1. DRAWINGS ARE NOT TOM SCALED, MITTEN DIIAENSONS TAKE PRECeWtCE TICS SET OF DOCUME:N7S ISWTDMS0 TO" USEO FOR WAGRA[dI,IATIC pURPDSES GNLV, DNLESS I M3ER OTHERVSE, THE GENERAL CONTRACTORS SCOPE OF WORK SHALL INCLUDE FURNtSHRNG ALL MIATERHALE, EQUIPMENT, 'LABOR. AND ANY PARWREMENT5 DEEh1ED NECESSARY TO COMPLETE PROJECT AS DESOBBED IN THE ORAWANB4GS AND OWNER'S PROJECT MANUAL Z PFIORTOTHE SU8M15SION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAIJOJARIZE THEMSELVES NIH ALL CONDMCNS AFFECTING THE PRCPOSED PNOZCT. CONTRACTORSSHALL VISIT THE C0115TRUCTPON BITE HTTH 1HE CG)ISTRUCTIONfeatrIRACT DMIJUENF570 VERIFY FIELD CONDITIONS AND COWM?A THAT THE PROJECT WILL BE ACCOMIRUSHED AS EROWI, PRIOR TO PROCBEDON; GRTH CONSTMUWHO9. OUGHT TO THE ATTE[�NTI , OF THEY EFUTORS,O RCMT'ciCTfaNGONEERR VERBALLY ANDALL RE WRITING 3 THE ARCIITTEF.T5f8 NOINEERB NAVE: 41AOf EVERY EFFORT TD SET FORTH NN TBE CONSTRUCTON AND COIRRACT DOCUMENTS THE COUPLETS 5COPISDP WORK CONTRACTORS 8MOING THE JOG ARE NEVERTHELESS CAUTIONED THAT PN40R CIISSIONS OR ERRORS IN THE DRAWINGS AND OR SPMFICLACHS SNALL HOT EXCUSE SAM CONTRACTOR FROM COUPLETOIG TH- PROJECT AND %TPROVEAIENTS INACCORDANCE WITH THE INTENT OF THESE OCCUPAENTS. THE BIDDER SNALLOW THE RESPONSIBILITY OF IIONFYIND (IH WRITING)THE ARCNITECTIENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIGR TO SUDMISSON CF COITTRACTOFM PROPOSAL W THE MIT OF DISCREPANCIES THE CONTRACTOR 51441L PRICE THE MORE COSTLY OR. EXTSMIVE IVORK. UNLESS DIRECTED OTHERWISE 4 THE CONTRACTOR$HALL SUPERVISE AND DIRECT THE PRCECT DESCRIBED IN THE CONTRACT pOCLIL[fTNTS SHE CQ[HTMCTOR SHALL BE SOLELY RESPONSIBLE FOR L CGHSTRUCTiON MEA14S. ME7XIODS, TECHHMLFSS, SEQUENCES• ANO F-0=13IJRES FOR COOR"ATING ALL PORTIONS OF THE WORK Ul IDER THE CONTRACT, 5. THE CONTRACTOR WALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO AUINUFALTURERSrVEHDOR'S SPEC[FlCATI015 UN LESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECSGENCE, 6 AtL LYCRK PERFORATED ON THE PROJECT AND LATERALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE COGE9, RE6LVTTO14B, ARID OFDNNAIICES CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWIE. CTHDI14AIJCE4L RULES, REGULATIONS ANDLAWFLIL ORDERS OF AHYPMC AUTHORITY, MUrACIPAL Alb UTILITY COMPANY S1NEC!FICATIONS. AND LOCAL ARD STATE JURTSAUCT)ONAL CODES GEMIN I DI4 THE PERFORMANCE OP THS WORK' 7 GENERAL CONTRACTOR SHALL PROVRI€-AT THE PROJECT SITE. A. FULL SET OF CONSIRUCTIpI DOCUMENTS UPDATE D WITH THE LATEST RENEW{% A740 ADOEIMA, OR CLAAMPICArMlAS FOR USE BY ALL PE BECAME L WVOLVFD WITH THE PROJECT THIS SET Is AVALID CONTRACT DOCUMENT ONLY IT THE TITLE SHEET IS STAMIPSD 'FOR CAI4 SFF[IJCRONN' PIO FATJi SVCC£SSSVE SHEET BEARS THE AF4CHIIEW 5 SIGNED WET STAMP. 0 THE STRUCTURAL COMPON ENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THISCONSTRICTION FRCNECT V14LESS NOTED OTHERWISE- 9 SEAL ALL PE14ETRATIONS THROUGH FIRE -RATED AREAS WITH U,L LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE. AIINGOF NOT 10 CONTRACTOR LESSTHAN 2.A0 AIVBC WITNNT75 FEET TRAVEABLE FIRE L MSTAI=TO ALLPORTIONSOF PROJECT AREA DURING CONSTRUCTION 11 CONTRACTOR SI�'1AEAMIAEuT3, PAVIND, CURBING, ETC. DURING COS TO PROTECTHSTRUCTNO" UPON COMPLETON OF WORK. CONTRACTOR SHALL RTJ+AOR MIT DAMAGE THAT MAY HAVE OCCURRED DUPE TO CONSTRUCTOR ON OR ABOMINE PROPERTY. 12. CONTRACTOR SMALLKEEP GENERAL WORI[ AREA CLEAN I;HO HA7JWDFR� DURING CONSTRUL'i11111 AND Dr-' OSE OF ALL OBIT, DFBRiB, AND RUBBISH CONTRACTOR SHALL REMOVE EGUIFMENT FIOT SPECUrIEO AS REMAINING Olt THE PROPERTY OR PREMIERS SITE SMALL BE LEFT IN CL CAN COUCH FOI AND FACE FROM PANT SPOT 5, DUST. OR SMUDGES OFANY [NATURE t3 THE OEl46RWCOHTRACTORSNALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTDN PRICE( TO STARTING WORK OI( ANY ITEM NOT CLEARLY DERINCO BT THE CONSTRUCTION DRA%%GSICOfJTLACT BGCUPAEFJTS 14 THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS. 15 THE GOIITRACTOR SHALL PROVIDE CWGUWRVARELESE, LLC FROPER INSURANCE CERT PkUTES IAMINC CIPKiDLAR WIRELESS, LLC AS ADCIRONAL PRSURED, AND CINGULAR WIRELESS. LLC, PROOF OF LICEIISE{Si AND PE I. PD INSURANCE. 16 CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AIID COORDINATING ALL INSPECTIONS 17 CAUTICH! CALL BEFORE YOU DIG! BURIED UT WTIE S E%iST III THE AREA AMID UtRRY INFORMATION SHQW4N MAY NOT BE COMPLETE CONTACT THE ONE -CALL UTILITY LOF�TE SEANCE A EBIAMUI.i OF dB MOURS PRIOR 7O COUSTRULTlOIi. 1•BAO-F363i55 10 CONTRACTOR TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS AND SUBMIT TO CINGULAR WIRELESS. I.L.C. ALONG WITH FIE DLIME D CONSTRUCTION SET 19 CONIRACTOR 70 DGCUUFiNT ALL CHANGES MADE I4 THE FIELD BY FIARWNG UP (FIE7O C11TAR YAR$LESS_tLCONCOMP-EIONI 011OUUPSUBhVTTINGTHE O REOiJNE SV 2U FOR COLLOCATION SITES- CONTACT TOWER OWNER REPRESENTATIVE FOR PARTICIPATION N BID WALK. 21 OVEN ERAL CONTRACTOR LSTG COORD1INATE ALL POWER LHSTALLATMN WITH POWER COMPANY AS REQUIRED, CONTRACTOR TO REPORT POWER INSTALLATION COORDINATIONSOLUTION(S)'10 NETWORK CARRIER REPRESENTATIVE, PROJECT CONSTRUCTION MANAGER AND ARCHRECT. 22. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT. MUST BE APPROVED 6Y CINGULAR C014STRUC'TIDII MANAGER, 23 ITN THE CASE OF ROOFT DP SOLU 710145 FOR EQUIPLIENNT ANDfO11 ANTENNA FRAMES WHORE PENETRATION OF EXISTING ROOFING MAYE14I41.5 OCCUFLYHE GENERAL CCII FACTOR SHALL COORDINATE WITH BUILGING OYSTER AND BURLDNO ROOFING CONTRACTOR OF RECORD FDR 41STALI All CPI. PAICFL REPAIR CIN Al IY AUGISENTA710I 7070E ROOF. MAD HAVE THB WORN GURRANTMO UNDER THE ROOFING CCUITRACTOR'S WA NRAITTY FOR FADISTURE PENETRATOR OR AND OTHER FUTURE BREACH OF ROOFING INTEGRITY GENERAL NOTES CONTID : 24. AN THE CASE OF ROOFTOP SOLUTIONS YA714 THE INSTALLATION OF AUFFENNAS WTRNIN CCIICEALEO(SHR000M) SUPPORT FRAMES OR TRIPODS. THE GENERAL, CONTRACTOR SHALL COORDINATE WITH THE FRP FJESIG NERTABRICATOR TO ENSURE THAT THE FINAL FRP SHRMO IS S0AL4ATNG ON APPEARANCE OESIGNATED EXISTING EXTERIOR BUILDING FACADE MATE RKL L TEATURE E, ANO COLORS- THE CONTRACTOR SHALT FURTHEMIORF ENSURE THE USE OF COUHIERSUNK FASTS NERS I IN ALL FRP CONSTRUCTION. WHEN PROTOSIMW LATIONS ARE MOVIDEO, THE COI 1 TRACTOR SHALL ENSURE THAT FINIAL CONSTRUCTIDIF REPRESENTS WHAT IS INDICATED III PHOFOSLIULA71oN_ SHOP CRAWIN" $11ALL BE PROVIDED TOTHE GENERAL CONTRACTOR, CONSTRUCTION COORDINATOR. AND ARCWTBCT PRIOR TO FABRICATION AND CONSTRUCTION 25. 14tiHE CF.SE OF ROOFTOP S91UTIO[NS FDR EQULPME)IT M13MR AFI MOZA FRAMES WHERE IU4CHOF0IG TO A OONCRE76 ROOF SLAB IS REOUPRED, CONTRACTORS SRALLCONRRM IPA] PRESEMNG ICI OF POOST THE ITEFTSMIATENDON55 YATHIN THE ROOF 5LA - RESULT�jIIOGANCKFTECT FROM Ali Av UNDOCUMENTED DESIGN CPWME IN THE EXISTING BUILDING'AC-MLT DRAWWHG SET--HANIN' INDICATED All ORIGINAL 1111=14 SOLUTION OF REV4FORC ED CONCRETE YII EM2i5MEB STEEL RE BAR. II THE EVENT POST TENSION SLAB SOLUTION IS PRESENT, CONTRACTOR SNAU, INCLUDE PROMSjQHS FOR X•RAY PROCEOURES INCLUDED III BID) FOR ALL PENETRA110N AREASI+IHEHE ANCHORING OCCURS 2A GENCRAL 65UD CONTRACTORS SHALL USE STAI146E95 STEEL METAL LOCH)IG TIES FLA ALL CABLE TRAY TIE DONISA!tO ALL OTHER GONE RAL TEE DOWNS 0YKERE APPLICABLE} PLASTIC ZIP TIES SHALL 140T BE PERMITTED FOR USE OH CNNGUWAR PROJECTS. RECOMMENFO MANUFACTURE SHALL BE: PANOUIT•CORF PJETAt LOOKING TIES MODEL NO. MLTSS-CP UNDER SERIE$41lO (OR EQUAL). PANDUIT PRDOUCT DISTRIBUTED BY TRUIRC OF 74CGTAA, WA. DESIGN CRITERIA: THE STRUCTURAL DESIGN OF THI6 PROJECT IS IN ACCORDANCE WITH THE INTERNATIWIAL BWLGING CODE 2053 WITH WA$HINGTON STATE BUILDING CODE AMENOIJENTS (2D031BC) OBSKOIN LOADS GESION DATA FOR THE CRY OF FEDERAL WAY, WA: -ROOF SNOW LOAD NIA (NOT A ROOFTOP SOLUTION) -BASIC WIND SPEED B5 MPH (3-SECOND GUST) _NHD EXPOSURE •B -SEISMIC DESIGN CATAGORY •O, CONCRETE NOTES: 1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACIJIII 2. CONCRETE SHALL BE MIXED.PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH CHAPTER 10 OF THE 20D31BC, STRENGTHSAT 28 DAYS AND MIX CRITERIA SHALL BE AS FOLLOWS TYPE OF CONSTRUCTION 2B DAY STRENGTHS WIC FAINIAUMCEMENT ire) RATIO CONTENT A SLABS ON GRADE PER CUBIC YARD TOPPING SUSS CONCRETE PIERS 2,400 PSI 45 512 SACKS B. ALL STRUCTURAL CONCRETE 4,000 PSI 45 612 SACKS EXCEPT WALLS C CONCRETE WALLS 4,000 PSI 45 612 SACKS CEMENT SHALL BE AST61 C1 E0. PORTLAND CEMENTTYPE 0 U N.O. 3 THE GENERAL GOUTRACICR SHALL SUPERVISE AND BE RESPONSIBLE FOR THE METHODS AND PROCEDURES C•F OOIC ROTE PLACEMENT. 4 ALL CONCRETE WITH SURFACES EXPOSEOTO STANDIRG WATER SHALL BE AIR.ENTMITTED WITH AN AIR-E47RU44HO AOEKT CONFORMINNGTO ALSTIJ C200. C404, Co S, CW4; AND CIO 17. TOTAL A)R CONTENT SHALL BE IN ACCORDANCE WITH TABLE 1 OW.2.1 OF THE 20D31SC 5. REUFIFORCING STEEL SHALL CONFORM TO AST14 AM Is (INCLUDING SUPPLENdERT 5$1 BRACE CR TYI'm.000 PSI, PXCEP71ON5: P41Y BARS SPECIFICALLY SO NOTED ON THE ORAWINOSSHALL BE GRADE 414Dy.40,000 PV' GRADE 60 REINFORCING BANS INDICATED D1i DRAWINGS TO OE WELDED SHALL CONFORM ID ASTM AIDE. RONFORC046 CDMPLY1NG VMH ASTM ABIS(S I)MAY BE WELDED ONLY IF MATERIAL PROPERTY REPORTS IMICATI413 CONFORMANCE YA7H YIELBING PROCEDURES SPEW'EOIN A.W S D14 ARE SUBMITTED, 0, REINPOR=0 STEEL SHALL BE DETAILED (INCLUDING HOOKS AND SENDS) III ACCDRDAP4CEWT7HACIa%AND710. LAP ALL CONTUJUVOS RE0)FDRCEUEJNT AT LE AST 7DEARDIAMIETL'RSORAM0NILILWOFgd'. PROVIDE CORNER BARS ATALLWAI,LANO FOOTING INTERSECTIONS. LAP CORNER OARS AT LEAST W BAR DWAEIERS OR A MIMLIUM DF 7-0'. LAP ADJACENT MATS CP WELDED WIRE FABRIC A MOUMVM Or VAT SIDES AND ENDS- 7 WELDED WIRE FABRIC SHALL CONFORM TO ASTM A•185 g SPIRAL REINFORCEMENT SHALL BE PLAIN WIRE CONFORIAING TO ASTM AOIS. GRADE 60 fy=00.000 PSI 9 NOBARS PARTIALLYEMBEUDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SD DETAILED DR APPADVED BY THE CONSULTANT. CONCREI NOTES {CONT 10 CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS, • FOOTINGS AND OTHER UNFORMED SURFACES, EARTH FACE 3' • FORMED SURFACES EXPOSED TO EARTH OR WEATHER OR LARGER) 2' (95 BANS OR SMALLER) 1 12' • SLABS ANO WALLS (INTERIOR FACE) IH, 11_ BARS SHALL BE SUPPORTED ON CHAIRS OR OGBIE BRICKS 12 ANCHOR BOLTS TO CONFORM TO ASTM A307- 13. PION-CARINKGROUT SHALL BE PUr I0SuMOV AIJAPPROVED MMUFAMM11 AND SHAU, BE MOC-D ALTO PLACED IN STRICT ACCORDANCE WITH THE LWILWACTUREFS PUBLISHED RECONNkBHOAT70IS. OROUTSTRENOTH SRALLBE AT LEASTEOIJAL TO THE MATERIAL ON YABCH FT IS PLACEONS000 PSI MNIMM4 14. ALL EXPANSION ANCHORSTO BE HILTI BRAND, ADHESIVE ANCHORS REQUIRE TESTING TO CONFIRM CAPACITY UNLESS WAIVED BY ENGINEER. STRUCTURAL STEEL NOTES: 1. SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO THE CONSULTANT FOR REVIEW PRIOR TO FABRICATION 2. STRUCTURAL STEEL DESIGN. FABRICATION A140 ERfnOT4 SNCLUDING FIELD WELMIG, HIOII5TRfHOTH FIELD DMITIPG, EXPANSION SOUS, AND THREADED CKPANNOI ANCPIRR5]SHALL BE BASED DR THE Al SC. •SPECFICAMPJ FOR THE DESIGN, FABRICATION, AN D ERECTION OF STRUCTURAL STEEL FOR DUILDWGS-LATEST EWROH SUPERVISION SHALL BE IN ACCORDANCE W142=IM CHAPTER 22. BY A CVALMED TESTING AC ENCY MEIGNAT ED BY THE CONJBLIL7ANT, I"-- CC1NSULT*JT SMALL FURNISH ED WITH A COPY GF ALL INSPECTION REPORTS AND TEST RESULTS 3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWINGREQUIRELIENTS: TYPE OF MEMBER A, S, PLATESHAPE5- ANSI LES, AND RODS AS1MA30,Fy30%S1 PL B. SPECIAL SHAPESAND ATES ASTM AM Fy ED K51 C. PIPE COLLRANS ASIM ABS Fy 35 KSI D. SIR IJMRAL TJBIIIG ASTI,I ABDO. Fy 41 XSI E. ANCHOR OCLIS ASTA4 ,AID? F. CONNECTION BOLTS ASTM A3251TMST{IFF•TY PE ALL MATERIAL TO BE HOT DIPPED GALVANIZED AFTER FABRICATION PER Al 231AMPA-00 5 ALL WELDING SHALL B E IH CCHPORMAHC2 VAT H A.I S.C. AHD AWE SIAIIDARDS AUD SHALL BE PERFORMEOBYWAD.0. CERTIFIED YIF,LDERS USND E70 )OCELBGIRODEL ONLY PRFQL"F1 EO VIELOS (AS DEFINED BY AWM ENJI LL BE USEO. WELDING OF GRADE 6a RFJNrORCINO BARS OF REQUIRED) SN ALL BE PERFORMED USING LONI HYDROGEN ELECT'ROOEB, NBL7ING OF GRADE 40 REINFORGNG BARS IIF REQUIRED) SHALL BE PERFORAWED USING ET07P[BLEC1YiQR'e5 n�cliau.G W7RNIN 4'OF COLD RENDS N4 REIIF13RC414G STEELIS RDTPERMMtO 5EE RERIFORCING NOTE FOR MAATERAL REQUIREMENTSOF WELDED BARS, 0 COLD•FORUEO STEEL FRAMING MEMBERS SHALL BE OF THE BHAPL 51:15, AIR) GAGE SHOWN ON THE PLANS. PROMOS MIBMUMI SECTION PAOPERTES INpIGUTED ALL COLO•FORLTED STEEL FRAMING SMALL CONFORM TO THE A' 5 5. 'SPECLFIGATI Oki FOR TI4E BEE IG!4 OF COLD -FORMED STEEL S7RUCTVRAL IEIAOCRS- 7 BOLTEG CONNECTIONS SHALL USE BEARING TYPE ASTM A325 BOLTS IN' DIA)AND SHALL HAVE A MINIMUM OF TWO BOLTS UN LE SS NOTED OTHERWISE, B NOIt•STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 54W DIX ASTPA A301 BOLTS UNLESS NOTED OTHERWISE O ALtSIFEE PAINTED IN ACCORDANCE NTH THE DESIGN S COASSTTfat"IM SPECIFICATION ORK SHALL AND IN ACCORDANCE WITH ASTM A36 UNLESS NOTED OTHERWISE. 10. ALL WELDS TO BE IA4'FILLET UNLESS NOTED OTHERWISE 11, TOUCH UP ALL FIELD DRILLING AND WELDING WITH 2 COATS OF GALVACON (ZINC RICH PAINT) OR APPROVED EQUAL TOWER/POLE NOTES: 1 VERIFICATION THAT THE EXISTING TOWER/POLE CA14 SUPPORT THE PROPOSED ANTFI4NA LOADING IS TO BE DONE BY OTHERS. 2 pROViDE SUPPORTS FOR THEANTEHMACOAX CABLES TO THE ELEVATION OF ALLINITIAL AND FUTUREAIIT&0tA5 AIFTEHNA COAXC:ASLEBARE TORE SUPPORTED AI4DRESTRAINED AT THE CENTERS SUITABLE TO THE MA NUFACTU RSRS REDUIREMIF.IJ 15 ABBREVIATED ROOF TOP SAFETY PROCEDURES WHEN APPLICABLE :. (AS PER ACCIDENT PREVENTION PROGRAM' -BY PERMISSION OF DIRE N CONSTRUCTION, INC. - 03101M FALL PROTECTION METHODS AND EQUIPMENT ROOF TOP INSTALLATIONS I FOR WORK IS BEING PERFORMED WITHIN 2FOF Ali IJRPROTECTED ROOF EDGE, THE CON45TRUCTIOH SUPERVISOR SHALL DESIGNATE ATRAINEO SAFETY MONITOR TO OBSENVE THE MOVEMENTS AND ACTIVIDE 5OF THE CONSTRUCTION WORKERS. 2. SAFETY MOMTUR SHALL WAJ4N CONSTRUCTION WORKERS OF HAZARDS (I.E., BACKING UP TOWARD A ROOF EOCE, ETC NOR UKSAFE ACTMTIES. THE SAFETY IJDNDOR UUST BF ON THE SAME ROOF AND WITHIN VISUAL AND VERBAL DISTANCE OF THE CONSTRUCTION WORKERS. 3. CONSTRUCTION INVOLVING WORKERS 10 APPROACH WITHIN 6' OR LESS OF AN UNPROTECTED ROOF EDGE. RECURES LYORKERS TO USE SAFETY LINE. 4, SAFETY LINE SHALL BE MINIMUM S-DIAMETER NYLON, WITH A NOIAINAL TENSILE STRENGTH OF S400 LBS. S. SAFETY LINE SHALL BE ATTACHED TO ASUBSTANTIAL MEFABER OF THE STRUCTURE 6_ SAFETY LANE LENGTH SHALL BE SET ALLOWING CONSTRUCTION WORKER TO REACH EDGE OF ROOF. BUT NOT BEYOND 7_ SAFETY BELTS SHALL BE WORN BY ALL CONSTRUCTION WORKERS B MONTHLY SAFETY INSPECTION A44D tAANTENAN CE OF THE FALL PROTECTION EQUIPMENT SHALL OCCUR BY THE SAFETY COLA h1FITEE REPAESENYATMEE. INCLUDING: INSPECTION OF CONSTRUCTION AREA FOR HAZARDS USE OF AN INSPECTION CRECKUST INTERVIEWING CM40RKERS REGARDING SAFETY CONCERNS REPORTING MID DOCUMENTWD A[FY HAZARDS REPORTING HAZARDS TO THE SAFE7Y COMIUMEE FOR CONICI DERATION POSTING RESU LTS OF INSPECTION AND MT4Y ACTION TAKEN RECEIVIIAG AN UNBUSED REVIEW OF ONES OW71 WOnx AREA BY ANOTHER COWORKER SAFETY REPRESENTATIVE REFER TO ROOFTOP WORK AREA SAFETY PROTOCOL NNATIONALASSOCIATION OF TOWER ERECTORS 2000 PUBLICATION REFERENCED OSHA REGUTAH ONSTANDAROS SHAL L OE REVISW>-eD BY TCWERBRS CT ORS, EQUIPMENT INSTALLERS, AND TOWERIROOF TOP C0IRTRACYCR65UB CONTRACTORS 2BCFR 1070=00•SCOPE AP1rLICA7iO1f, AiH)DEFI!NNTi0f15 20 CFR 1070 501 -DUTY TO HAVE FALL PRD7ECTIOI 10CFR W20.502 -FALL PROTECTONSYSTEMSCRIT ERIA AIID PRACTICES SYMBOLS AND ABBREVIATIONS AIC AIR CONDITIONING HORZ HORIZONTAL SHT SHEET AGL ABOVE FINISH GRADE HR HOUR SIIA SIMILAR APPROX APPROXIMATELY HT HEIGHT SPEC SPECIFICATION HVAC HEATING SF SQUARE FOOT ELM BUILDING VENTILATION SS STAINLESS STEEL BLK BLOCKING AIR CONDITIONING STL STEEL STRUCT STRUCTURAL CLG CEILING ID INSIDE DIAMETER STO STUD CLIFF CLEAR UJ INCH SUSP SUSPENDED CONIC COSST CONCRETE CONSTRUCMI INFO INSUL INFORMATION INSULATION THRU THROUGH COIN CONTINUOUS INT INTERIOR TNNG TINNED IBC INTERNATIONAL TYP TYPICAL DBL DOUBLE 13UILDING CODE UND UNLESS NOTED OIA DIAL DIAMETER DIAGONAL LBS POUNDS OTHERWISE ON BET DOWN DETAIL MAX PAECH MAXIMUM MECHANICAL VERT VERTICAL DWG DRAWING MTL IAFR METAL MANUFACTURE VIF VERIFY III FIELD EA EACH PAGR MANAGER WI WITH ELEV ELEVATION MIN MINIMUM NO WITHOUT ELEC ELECTRICAL MISC MISCELLANEOUS YIP WATERPROOF ED EQUAL EQUIP EQUIPMENT NA NOTAPPUCABLE EXI EXTERIOR MC NOT IN C014TRAC-T NTS NOT TO SCALE FIN FINISH FLUOR FLOURFSCENT OC ON CENTER FLR FLOOR OD OUTSIDEDIAMETER FT FOOT PLYWO PLYWOOD GA GAUGE PROJ PROJECT GALV GALVANIZED PROP PROPERTY GC GENERAL CONTRACTOR PT PRESSURE TREATED GRID GROUND REO REQUIRED GYP SO GYPEUMWALLBOARD RM RD ROOM ROUGH OPENING - T- TELEPHONE -E- POWER -G- GROUND WIRE COAX- COAXIAL CABLE 0 ANTENNA CENTERLINE (E) EXISTING (N) NEW e OETAILINUMBER SHEETNUMBER UNA� l.7 CITY OF FEDEF BUILDING D 2 0 CU .J GX W �u SA ca-D-- MISTIME tizi PE23IIB ST, RA[E= HLIE:[ISMITR W'DODIMELEWARM FAX LiffM A r BAL. dgmllf tv= l!l i DATE, D61D•Ds DRAWN BY- AJB CHECKED BY: I.IWO REVISIONS DATE DVSIF 1 f"l gFflP,1 06010IDS PIIPDH l9AA AJ0 00124105 Z0111110 BUOI.UTTAL AJ0 111#lay FIBAI CI'S AJD SITE WA931 RANEN 30929 8TH AVE SOUTH FEDERAL WAY, WA 98003 SHEET TITLE GENERAL NOTES SHEET NUMBER G-1 I I I 17 I f 1 ZONED RS 7.2 i 16 ! -r� i 15 L TL# 082104-9058 ZONED RS 7.2 CELLULAR SITE PORTION OF NW 1!4 OF SECTION 8�21 ., R.4E., W.M. CEI JOB # 05-66005 s " r L �' � f � �T�Lf 1VATifil71ESC11T%pl 14 , PARGELA'�I �r l '1 TL; 082104-9029 ry I � 13D,OZ7 50. FT �xIAGREs 13h EVR'x+OER TG.WEFl : .. a I OM `♦` Z � - � \ OSI11001IAi110 T � rrrryrr�yy��,,,���Tff 1 Q� I d3 6 12 2 I_ � � N9&L•'A7��1 r_—___--__—T___.__— ! i I KCSP 880064 I 6211150795 ZONED RS 7.2 I i LOT 2 ! LOT 1 FyJ5N11G CHWNLYIK FENCE I 20.ar SETBACK IW W I� PARCEL B ! c C ! N Im �� E S S6.5223'E L ^ S BB•5Z23' E 120.110 10tp-TiEi DA� / 1 i ! C>OliPI411NLW+ JIf races IiELA TDM-cDr4 EYi --dV11X 711 PAA FYISTINO DATE 9 NTi,ITY E.EAE VAI11 � b � rlsuluxF.L GArorET. AtcLss ROAD PxlsrttlD OATS TW-lux. POOET D01H1D1DA'BR AIM L IGIR 00, UE,rM= U4E BASELEl�I ATN5=4e2 TL# 082104-9207 ZONED RS 7.2 OVERALL MAP 40, D 40 HU SCALE_ 1'24O' LEGAL DESCRIPTION- LEGAL OESCRPTION PER CHDCAGO TITLE INSURANCE COAIPAIIY CERTIFICATE Na 11052TO PARCELA TFIE SOUTH KAU OF THE NORTHPAM cum- 5R OF HE gCUIHEA11T QUARTER OF THE "CIATIM'E ST GUAR TER OF SECTION IL lOYA45WP 21 NOR7}L RAMIE 4 EAST. N1LTJIMETTE MGRdIWL IH KIIIO COUNY. LYASHRIGTON, OMEPT THE UQRTN FIALF OF tHE SOu!}lLhHT QUARTER OF NIE NORTHEAST OUARTEROF THE SOUTHEAST QUARTER OF THE NORTHWEST GUAR]PR OF SHED SECTlgtl D: AHD F,ILCEPT THE SOUTHEAST QUARTER OF THE SOUTHWEST QUARTER OF THE NORTHEAST QUARTER OF THE SOUPIEAW QUARTER OF THE E7 A THE SOUTH 30 FEET OF 7HEE S SOLITFRVEST OU40E OFHSSECTION SO H VES QUARTER OF THE HORYNEAST GUEd1TE MR EE "VEST7D EAST 30 FEET AND TOGETHE R WITH F 5OUHEArS: QUARTER OF THE NORTHWEST OUAFTTER OF SAID SECTION E. AUD FLR111ER E%CEPTI7NG TNt Y+ES1 TC7 FF ET OF HE EAST 177 FEET OF THAT PORTION OF ME SOUTH HALF OF THE SOUTHEAST QUARTER OF rAETTf R OW HLYIL 4FNOFLTI'{ UTH O y G ARyER OF SOUTH 70 -ME FEETNORTHWEST OF SECTION B, TOWNSHIP 21 NORTH. RNfQE A EAST YlILLA PARCELS: THE WEST i20 FEET OF TFFE NORTH HALF OF HE SOUTH£FSTOUARTER OF THE NORTHEAST OUARTEA OF THE SOUTHFwz QUARTER OF THE NORTHWEST ARTETT OF SECTION 4 TOVWNSH+P 21 NORTH. RANGE 4 EAST. YALLANETTE MERIDIAN. IN LONG CC:INYY. WASMI'M N H; OU EXCRPT THE 3a FEET THEREOF COINEYEO T D KING COU14Y. WASHLNOTON FOR ROAD BY DEED RECORDED UNDER RECOROR4G NUMBER 2507904. IN KING COUNTY. WASHHGTTON- 6 TL# OB2104-9105 ZONED RS 7.2 I S 08•52'37' E T47-00' EFISTINU DATE I— I TL# 082104-9205 I ! I 1 tr E I N��R`� NAD &3MPCS NORTH ZONE svu: avar I I ° ! I w SOUTH 309TH PLACE ! y IDUIIDvs' 1 ] 1' AETALPOST _— Co I I ! I ry ! 1N IF -� - SOUTH 310TH PLACE I VICINITY MAP NTS KING COUNTY 91TE LOCATION FOUND URASS DISCHN 4' CONCRETE POST IN CASE 1) RCS 87050amm OS 01103DWID PLAT OF EVERGREEN ESTATES 5001 4) PLAT OF WESTRIDGE Ile 2 S)_PUTOF61iLTN=O VILLAGE 6) AS.EESSORE LUPLIW SEC- S. T 211L R 4E —T— OVERHEAD TELEPHONE —c— OVERHEADCABLE OVERHEAD POWER) TcLICABLE --w— UIIDEFOROUNDPOWER —UT— ULIDERGROUIDTFLEPHOIE —DC— UNDERGROUNDCABLE UNDERGROUND GAS WE —HAY-- UNDERGROUND WATER UIr —ss— SANITARY UILE —5:— STORM LIME -0 CHAIN LINK FENCE ^ - WOOD FENCE --�( -- BAREEDWIREJWIREFFNCE FOUND MONMISI17 III CASE } FOUr+D BRASS DISC SET BAR & CAP CONTROL ONLY O FOUND BAR &GAP HUT1AGd SETT tAAGLW LYf WASHER :IAIL SET MAGIAIL FOUNDUAGIIAIL ® FOUND IRCIN PIPE 3 EKISTING SPOT ELEVATION ® DRAIN BABINHOUIID CGSCHPASIH 6 RRE HYDRANT [� WATER VAULT 8 WATERMETER pd Wy WATER VALVE C�7 GV GAS VALVE .-.-0 LIGHT STANDARD a POVER I UTIUTY POLE E_ POLE GUY WIRE PAD MOUIREOTRAIISFO.R)EER POWER VAULT POWER METER ® TELEPHONEVAULT TELEPHONE RISER �- SIGH m MARKER -.o.- UCMARKER .-. HIGHWAY MARKER ALL ELEVATIO14B SIIOWII ARE ABOVE LEAN SEA LEVEL ASL1 ELEVATIO+IS REFERENCED TO THE ILAVD E8 DATUM ALL TOWER. TR=At1D AFPURTEIIANCE EE-IGHTS ARE D''a GROUND LEVELIAGLJ ALL HEIGHTS REPRESENTED ARE ACCURATE TO _02 ET UPTO Iol Ill HEIGHT OR t02 %OF TOTAL HEIGHT kA& ECI S GFLEATER TI W I W7- DECIDUOUS hl=ALDER MP=LWIE AL12 -TRUNK DIMTER RNI DS=OECIWOUS `-TYPE_ MA=MADRONA' YERGREEN OK=OAK CH- CHERRY 0 EASEMENTS: CE=CEDAR DFIS -TRUNK DIA6=fER 1111) ➢F=DOUGLAS RR 1) PACOV7ELE•IIONEANTTELEm4A1`11 1952 HEEIGIRAGL TIE=HFULOCK PCFE MID WIRE EA5E9,18R.AFN 1117117m. IF NFASURED PI=PINE DES CRIPTIO' NOT SNIFF MNT TO EVG= EVERGREEN DETEI4NWELOCATIDN ® Q 2) NINO Cowry WATER 007111GT AN; SHRUB ) SUSI I WATER YAW RMENENTAFFECTAN upiamFAwntu PDITTm OF TS'ELA'SES THEE DRIP LINES ARE TO SCALE. TRUNK DIALEF-RS AFN NOT DISCLOSED ITNE APFRONUMEDAT 35 TP 4 D ABOVE GROUND L£rr-L 'SHOWN AILS FOR FEEFERFJILE ONLY ALO] OTILf3t 1REE5,AIaD VEGETATNWI MAY DZI Call 2 Working Days Before You Dlg BITE NHFDRMAnDN: 11 4 tJ rt F•f 1-800-424-5555 SITEADIIUNSER ;MFI-INH2O SITE hDU-SS IG'li Sill Al r3[iF_59UR! FEDERAL YWAT, WA t3QM Ulili9eSU7:dergrouMLow lion Center SITECONTACTIOWLER LAxENAVENUTILITY DISTRICT (ID,MT,ND,OR,WA) GTAII FRENCH 6.4ETYPR,i n.IDwLDEiDrlN.eulmxrcartlu-rcF; IAi PIIOHENUNBER 253945.54N ALLTPEIh1W* NI ACCJSDAIGEWaIcLW,1 2011ING RS 1.2 - ELECTI MD SF1,ENrWtEw Des -1F,lW s Tr.o.v. TOTALLQTAR£T 139yDSF(321t AC) EVA1v.EnuF:E Mowm-uMte Alm- PTO,ECT AREA APPRGX 320 S F. BOUNDARY DISCLAIIIAM THIS PLANDOES TROT REFREs Wr A BOUNDARY LATYFIIDL' I LONGITUDE POSITION: 5 URVEY, HIS iS A SPECLAUYED TOPOGWIfic ppppD1lµTE QALI�I JITRQFWAl17LTA1D: MA,P SNTR PROPERTY Lp1ES AND EASELIEHTS LAT. Ar-MAWN HAD 83 BEING A GRAPHIC DEPICTION OF VAMOU15 LDIIG- IM7319V W NAD 83 INFOR0.MTiON GATHERED FROM PREDMINAAY ELEV=450 DID FEET IIAVD 99 1 Ila- REPORTS. SACKAUP DOCUMENTS OF RECORD. MAPS AND AVAILABLE MONUMENTS FOUND DURINGTHE FIELD SURVEY. NOPROPERTY NOIWI.tENTS WERE SET. NO TTTLEN2SEARCH WAS DENC1{AIARK PERFORMED BY CORNERSTONE ENGIN£ERINGING BENCH NAI0: 10 RFTI DRAYANG INFORMATION: 00 NOT SCALE DRAWINGS. CONTRACTOR MUST CORE STATION ELEV=43 IT NAVD Sa VERIFY ALL DIMENSIDNSAND ADVISE CON5ULTANTS OF ANY ERRORS MID OI.DSSIONS ALL PREVIOUS ISSUES OF HIS DRAWING ARE ENy}lhTARtI DIS CLA]HaER:. - 6UPERSEDEDIB THE LATESTREVISION.THE FIEVARM15 ESTAW31JED AT TI[I$ SITE AFE INFORMATION CONTAINED IN HIS SET OF PIEFEREIRIZI 71@ABOVE HAWED CORS 6TATIOtI NO DOCUMENTS 15 PROPRIETARY BY NATURE ANY EFFORT WAG Ut=TO CHECK FQR>c USE OR DISCLOSURE OTHER THAN WHICH IS TIE 0-5VATONB ARE ACCURATE RELATED TO NAMED CLIENT I STRICTLY Ty ICE DFORYIGSFSTO PRpsDDFtF,D, ilas WRVEV VIAS PERFORU=DWRR I A 7SL°CQII GPT 7LG7 ELECTRON ARC AND WASIANG CLSTAIICE _R%1PPM0( DJI IN4, & TOPCOM LESA DISTAl15Ea D•SIPFUx Og1NF IIG5 CA5Rpi CdWAtLFDAFAC 2o04 2 0 U 4IC Wvv IL U X �O C6FiNER5 aDME 14 11r=111EI.S.TEMO P1l]Il A25EE117. ri.W'NAIEV.MGMU :XT 425E511731 ELWL Ee��l,as>narN� DATE: 06 T DRAWN BY: AJB CHECKED BY: 1TIA CAi ITESi3tp " nluu- US115105 FAEUYCm5 AA orTufn DFNOLVTTAL A£/ T. 41.`L 4LT Ter RE] Ixcnvr SITE WA•931 gg''� RANEN-3 pD 30929 8TH AVE SOUTH FEDERAL WAY, WA 98003 7 SHEETTITLE SITE SURVEY Y SFc- BER 1 i I T A (E) DOUGLAS FIR \1, , I I• :'' ' } r TREE (TYP) `WETLAFA IL1TY NTiDN 3 D ' 3o�!` D III/ I (E) MANHZ)E/ a +-tit •�`\ 11 III I I + PARCELA �t�, � �.z / ,� ems.:. ::.;•I'� � 1 �^ � � _ � � �� I d TL #082104-9029 l �� 139927 Sq. Ft. 4'' r Lsp �l 3r — ` 3.21 Acres ` i (E) 96'A" WATER TANK j P ---`[1— l 1 � :. .. s' �-:._ (E CE(TYP) XA �. 1 _� \ - . Y•r r ...`� � .i>=y SUILF}ING � ~ / `�� ky: "r�»r=:'r: "'�f ` �;• s /� PROPOSED RAILROAD TIE STAIRWAY 1=x�LU J:: Fri �':+r`aS} :` (E)TREELINE 1 Ill �; •", .s.� 1 � . C•. a -.i. i. n.a W 082104912 18190 Sq. Ft. : = i ..,�y.kY'".' . ; :•. 0.42 Acres =�: +:ems , • . • . -r.� • 1 (E) WATERY irr.' - 7 : s • �_s,�r" 0 1 + ' Jd • -1..,..:Y"... E) BUILDIN _ dR TT EE (TYP) � • --: ": `. �.r. � -. i •4L..e r '• '� _ I � r �1 Tit"?:i.:.�.�,s�y.:.M;� �y ��• i.• (! 1 1 1 i y. ! •I , �i yti" r v: i �Y Iy (E) PINE TREE (TYP) Ilk'- rj L(E}TELCOPE➢ESTAL E UTtUTYPOLE•!L' -� "�' `'s( �`':�'��• ( ) r. �µ ti."•r. �L >.y'n._. ..J:V •. . te r• C. •�J - EXISTING LEGEND SUBJECT BOUNDARY LINE ' • I -- - RIGHT-OF-WAY CENTERLINE I — — RIGHT-OF-WAY LINE I — — ADJACENT BOUNDARY LINE oP ---- OVERHEAD POWER LINE UP,— BURIED POWER LINE l BURIED GAS LINE I }' I oT .. .- OVERHEAD TELEPHONE LINE I it UT BURIED TELEPHONE LINE .. W - BURIED WATER LINE w . Ss - BURIEO SANITARY SEWER 1 PARCEL B so BURIED STORM ORAIN — >— — DITCH LINEIFLOW LINE i ROCK RETAINING WALL93 m VEGETATION LINE I IxI o CHAIN LINK FENCE I y WOOD FENCE 1 REFER TO SHEET A-•2 FOR ENLARGED SITE PLAN T _ S 88'S2_23- E 120.0(Y 235'-10' (E) UTILITY POLE -I — BARBED WiRFJWIRE FENCE TRANSFORMER -9- FIREHYDRANT I 9 LIGHT STANDARD 14 GATE VALVE I I P POWERVAULT L WATER METER ! �- UTILITY EOX A FIRE STAND PIPE 3 UTILITY POLE ❑ TYPE 1 CATCH BASIN ' E— POLE GUY WIRE 0- TYPE II CATCH BASIN 1] GAS VALVE SIGN l I Li GAS METER BOLLARD I Of TELEPHONE VAULT = MAILBOX a TELEPHONE RISER 23121 SPOTELEVATIDN S 88'5223' E i 33.28 I x I I I I i I 1 I to ZD I� Q , Lu E Iw f IQ fr S 88°52'37' E 147.00' I p~O ^;` .ati :`,•%�+' "�;. �: .�.r: �"' ice.-..:; q'•..'�� e� � �� "air „AE1 •a. .t,, ~�N GRAPHIC SCALE i J L� 4 CY� lU 20, 0 10' 20' 40' 80' 7/1 z /�c)�`l ARCHITECTURAL SITE PLAN r , 24'X36'SCALE:1"=20'-0' II"rmr�n.a.waeTab CID GRPlIVISiSCO Ni[ umtkE3IDH9L91BE2m Bm/2iA4.173t SIAL, 1lF = FAX /IIARl.Tr3t DATE: 117-12-07 DRAWN BY: rue CHECKED BY: 6two REVISIONS DESCRIPTION m ZONING SUBMRTAL IS FINAL CDs Ii EPDXY MTD TO WATERTAN° IT 2 REVISFAPER p.JENT IT ] REV PER AIRI50ICDON DC ;r' U W'LgNryppy q0 ramruLti p�rw ExPIREs ozrlssa SITE WA931 FEDERAL WAY BUENA 30929 8TH AVE SOUTH FEDERAL WAY, WA 98003 SHEET TITLE ARCHITECTURAL SITE PLAN SHEET NUMBER A-1 I / / - •' j II JJ Ij W W Iw W (E) 9W-0' WATER . •If I ( w I w >�� w TANK r J W Iw W W w W W W I4, v 1-4- -4, I w W+ W jw "/•• W I W w� W W w f 1 wl W W wf W W W w W HVAC UNIT l w) I I w I + • I Vi y- W W W W ..T� y St ■�I In c n, 7 , • y r y • •I y jI )ROPOSED-1 w w w w I ILRO D TIE L AIRWAY I Y V• • / V. w W w w w W W 12 • r - y / W w W W Iy W .Y / '• y � W w/ W w/!! w w • ' y .y W �w w �G W v • "'4 •, • % GRASS W • v w W w �, W W W/ W v W JW W W '4' W W GRAPHIC SCALE f 5 ENLARGED 0 1 2 SITE PLAN 1 24'x36" SCALE:118'=1'-W R-3 Nwu, r, ne aeblmT+ea e7 ule aurveY (II aW i4�b) L !� W W W w W w w y y w W W W W w w 4 w 11=0' y y W f w CM(Y SHM,TYER1:1 L W W W v w w w W •Y w V• `+ r� SECTORS GRAPHIC SCALE 5 0 1 2 5 y6 ;TOR C OF SECTOR A Nmn la a. a.mllrmla LY wa cuNeY Ilf ava7ehb) ANTENNA PLAN 24W6' SCALE: CONSTRUCTION PLAN KEYED NOTES Ot CINGULAR aW EOLIPMENTSHELTER TO MATCH EXISTING BUILDING ON PROPERTY 5 LEASE AREA SEE SHEET As, O4-0 PIPE BOLLARDS, SEE I IA5.1 ONOKIA ULTRASTTE CABINETS NO. 1 & 2 (PRIMARY -PROVIDED BY CI(IGULAR) BEE DETAILS SHEET A32 OIIOKIA ULTRASTTE CABINETS NO.3 5 4 (EXPANSION -PROVIDED BY CINGULAR) OUISTS CABINET. SSE DETAIL SHE E) Aa2 PROPO8P0 ANTEIINA MOUNTS (PR OVIIED BY CONTRACTOR) PAINTED TO 14ATCH EXISTING O WATER TANK SEE CETAS 16 21A-5- 70 PURCELL AUICLUARY EOUIPMENTCAMMET. e0 POWER CABINET. SEE SHEETAM2 v 4'A•XTU'WI20MWUTE 11OlLDWMEDO TALDR%MTHNSTEELFRAME O(PROVIDED BY CONTRACTOR) SEE 9T$ET Ail OIY PROPOSED ANTENNAS(PROVA41)BY ONGUAR)PAINTEO T0161ATCH EXISTING WATER TANK SEE RADIO PLAN SHEET A4 4 OF4AMS 47A41 & 371E CCAX{AL CABLE (PRDYIOEO BY CINGULAR)TO ANTENNAS 1e SEE COAX LENGTH SCHE OULE ON SHEET A-2 AND COAX NARKING CII SHEET A.7. 15 (4)SCH. 4D PVC CONDUIT RUN UNDERGROUND (PROVIDED BY CONTRACTOR) SEE DETAIL 31A3.3. 8SEE SHEETS E-3, Ea 1. 6 E-3.2 FOR GROUNDING TYPICAL 19 PROPOSED CINGULAR UTILITY EQUIPMENT. SEE SHEET E-21 SITE NOTES 1. VERIFY ANTENNA RAD CENTER & AZIMUTHS WITH FINAL SITE CONFIGURATION SHEET FROM R.F. ENGINEER. 2. ALL EXPOSED ANTENNAS. COAX, AND MOUNTING HARDWARE TO BE PAINTED TO MATCH PROPOSED WOOD POLE 3. CONTRACTOR SHALL ENSURE THAT ALL DISTURBED AREAS INCLUDING LEI PRIVATE DRIVEWAY ARE RESTORED TO EXISTING CONDITIONS, HVAC EQUIPMENT NOTES 1. EXHAUST FAN 15 TO BE MOUNTED AT THE POSITION INDICATED ON THE PLANS. EXHAUST FAN SUBCONTRACTOR SHALL PROVIDE FINAL OPENING SIZE AND HEIGHT TO G.C. 2. THE THERMOSTAT IS TO BE CONNECTED TO BOTH THE EXHAUST FAN AND THE MOTORIZED IN TAKE LOUVER. THE HONEYWELL THERMOSTAT MODEL NO. 2ES31 IS TO BE WALL MOUNTED ABOVE THE IN TAKE LOUVER AT 8'•0' AF.S. 3. THE MOTORIZED FIRE DAMPER IN -TAKE LOUVER IS ASHOEMAKER LOUVER 4500.3000.0130 AND IS TO BE MOUNTED AT THE POSITION INDICATED ON THE PLANS. 4. NOTE TO CONTRACTOR: ALL VENTILATION EQUIPMENT, DETAILED SPECIFICATIONS, AND INSTALLATION PROVIDED BY PACIFIC AIR CONTROL, 11812 NORTH CREEK PKWY, NO.104, BOTHELL, WA 98011 CONTACT: ED GOETZ PH: (206)682.6393 COAX LENGTH SCHEDULE COAX LENGTHS ARE CALCULATED FROM THIS DRAWING �n SET. ANY DEVIATION FROM THE PROPOSED DESIGN MAY !,"g EIV REQUIRE ALTERATION OF COAX LENGTHS. CONTRACTOR SHALL ENSURE THAT FINAL DESIGNAND COAX LENGTHS ARE COORDINATED. `' U h 2 5 2 CITY OF FEDERA SECTOR LENGTH I #COAX ""DLF{M R-I SECTOR "A" 180' 1 4+2 1 1 5/81, SECTOR " S" 240' 4+2 SECTOR "C" 180, 4+2 2 0 CU G< w w U X �GOlRf4E347A C)TV® C II 011leellln A, �MQ- 5[2H fE7:IM 5T.5JOE�0 Hf0.41=�f.W.1T.Q YAD07I/T.L.WATBQR FAh 42iiGF,RBI CiISIL- pi�e•epmq DATE: DD-10415 DRAWN BY: Am CHECKED BY: Mwo REVISIONS P4TE-I DEr'T%IIPIIDII I,Ii11Al moll Ci PAemlf Ail �L•V'nT 1wa3y�So ul k ¢+rr s Tp '�C75S� wW FdSA7kAi EM-5 pylSYjd SITE WA931 I— RANEN 30929 8TH AVE SOUTH FEDERAL WAY, WA 98003 SHEET TITLE kYENLARGEDS(TE PLAN __ i SHEET NUMBER A-2 GGi eM18�8 CNo =Fffm7iH"f um= Rgl�Q5M1.12i2 WDWWlMIEWAffiM FAIC RSrM2.17J1 EMAL• d /e1�am DATE: 08.10.05 DRAWN BY: A1¢ CHECKED Sr. 1,1wo REVISIONS OATF DESCPJP110N IMT W 110105 MwL. m9 AJU 05r2sr052°11111°SUDM47AL A-0 11122105 FIRAL ma AJJ aK w. nr .}i dro 0 w a 72nA 4 FRAM mt568 SITE WA931 RANEN 30929 BTH AVE SOUTH FEDERAL WAY, WA 98BU3 SHEET TITLE ELEVATION SHEET NUMBER A-3 WOOD 318'0 LAG BOLT OR SIMILA' TO SUIT WOODEN POST KATHREIN GP81011 coMBINED ANTENNA 2" O.D. GALV. STEEL JNTING PIPE .V STEEL MOUNT ANGLE X FOR ANTENNA OF 2) ELEVATION NOTES: I- LOCATION OF ANTENNA MUST HAVE CLEAR VIEW OF SOUTHERN SKY AND CANNOT HAVE ANY BLOCKAGES EKOEED)NG 25 % OF THE SURFACE AREA OF A HEMISPHERE ARC UND THE GPS ANTENNA• N 2. ALL GPS ANTENNA LOCATIONS MUST BE ABLE TO RECEIVE CLEAR SIGNALS FROM A MINIMUM OF FOUR (4) $ATELLSTES. VcRIF 1 WITH 2�3� HANDHELD GPS BEFORE FINAL LOCATION OF (BPS ANTENNA PLAN -BASE VIEW GPS/E911 COMBINED ANTENNA NOT TO SCALE 5 10 1/4" i �n FRONT TOP � { "v ED fD LWJ BACK SIDE KATHREIN ANTENNA: 742 265 ANTENNA DETAIL 24'x36" SCALE: 314"=V-0' 1 Or-t I II I 1514 I II I PARTIAL EAST ELEVATION 24'x36" SCALE: 112"=i`-0" ` CONSTRUCTION PLAN KEYED NOTES CINGULAR CMU EQUIPMENT SHELTER TO MATCH EXISTING BUILDING ON PROPERTY & LEASE AREA - SEE SHEETA-4. NOKIA ULTRASITE CABINETS NO. T52 (PRIMARY - PROVIDED BY CIrIGULAR) SEE DETAILS SHEET A-32 NOKIA ULTRASITE CABINETS NO- 3 E. 4 (EXPANSION - PROVIDED BY CINGULAR) OUI&TS CABINET.SEE DETAIL SHEET A-3.2 �r PURCELL AUXILUARYEQUIPMEIlTCABINET OPOWER CADINET. SEE SHEETA32 /t COAX CONDUIT EXIT ENCLOSURE (PROVIDED DY CONTRACTOR) COAXIALCASL° (PRGNDEO EY CINGU(1R)TO ANTENNAS. is SEE COAX LE 115TH SCNED ULE ON SHEET A-2 AND COAX MARKINQ ON &NEETA.T- 1S CB)SCN- al) PVC CONDUIT RUN UNDERGROUND (PROVID ED BY CONTRACTOR) SEE DETAIL W" 3. 3SEE SHEETS E.i. E31. & E-32 FOR GROUNDING TYPICAL. Ve PROPOSED CINGULAR UTILITY EQUIP14EM OGP51E011 COMBINED ANTENNA (PROVIDED BY CIN CULAR) 1,14CHORED TO FACIA SEE DETAIL S/A-3.1. SITE NOTES 1. VERIFY ANTENNA RAD CENTER & AZIMUTHS WITH FINAL SITE CONFIGURATION SHEET FROM R.F. ENGINEER. 2. ALL EXPOSED ANTENNAS, COAX, AND MOUNTING HARDWARE TO BE PAINTED TO MATCH PROPOSED WOOD POLE. 3, CONTRACTOR SHALL ENSURE THAT ALL DISTURBED AREAS INCLUDING [El PRIVATE DRIVEWAY ARE RESTORED TO EXISTING CONDITIONS. HVAC EQUIPMENT NOTES 1- EXHAUST FAN IS TO BE MOUNTED AT THE POSITION INDICATED ON THE PLANS. EXHAUST FAN SUBCONTRACTOR SHALL PROVIDE FINAL OPENING SIZE AND HEIGHTTO G.C. 2. THE THERMOSTAT IS TO BE CONNECTED TO BOTH THE EXHAUST FAN AND THE MOTORIZED INTAKE LOUVER. THE HONEYWELLT14EMICSTAT MODEL NO. 2EB31 IS TO BE WALL MOUNTED ABOVE THE IN -TAKE LOUVER AT V-O' A.F.S. 3. THE MOTORIZED FIRE DAMPER IN -TAKE LOUVER 15 A SHOEMAKER LOUVER 4560-3000-01313 AND 15 TO BE MOUNTED AT THE POSITION INDICATED ON THE PLANS. 4. NOTE TO CONTRACTOR ALL VENTILATION EQUIPMENT, DETAILED SPECIFICATIONS, AND INSTALLATION PROVIDED BY PACIFIC AIR CONTROL, 11812 NORTH CREEK PKWY, N0.104. BOTHELL, WA 98011 CONTACT: ED GOEfZ PH:(206) 682.6393 RECEIVED" JLN 2 17p 2007 CITY OF FEDERAL WA BUILDING DEPT. O U C< w w U X �C6l0.N�3 TONE UAII HEW"ST"SIAfEZD RM (tSAl-17V WDDOHiR1E.WANV2 FAX' 41dA91.IM Em DATE: 0Ia0.05 DRAWN BY: ALB CHECKED BY: N(wo P� 4Y. OC ap vey o f in P ]77GI h p4F�arsT�Ea�� "a+uxAL E1` ElT17E5 py15ffi SITE WA931 RANEN 30929 BTH AVE SOUTH FEDERAL WAY, WA 980D3 SHEET TITLE ELEVATION(S) & ANTENNA DETAILS SHEET NUMBER A-3.1 47.24" 44,27" 26,59" 20.65" 2 97' U 0a _ LL O lu __ UZ(7 By ?azm a< F U Z I] Z Ill z a F o w x J d � aff N Q / w N .j 0CV ti! N N N 3GP241 POWER CABINET -% D NOKIA ULTRASITE CABINET PRIMARY CABINET 3.60" 20.12" . 27i2"- 43.74" UNITS CABINET ANCHOR FOOTPRINT UNITS EQUIPMENT SPECIFICATIONS ULTRASITE FRONT ELEVATION 9 NOT TO SCALE 11 NOT TO SCALE O NOT TO SCALE NOKIA INDOOR ULTRASITE BTS DIMENSIONS NOTE: WLS & E911 EQUIPMENT TO BE INSTALLED WITHIN MANUFACTURER: NOKIA POWER OR AUXILIARY CABINET ASAPPLiCASLE• HEIGHT: 70.9" DEPTH: 24.4" WIDTH; 23.6" WEIGHT (WITH UNITS):594 Les FTi } 3' 24.4" G a m _ 10• IT 5- ;,- 7 FZ6PLNTH OF PLINTH OF 1 I w cm CABINET 1 CABINET N N 11 •f. 4" 22" �I 22" I �j � I, Ail RE o o a dn• IBN, E 1~ i � 4 P7 FLOOR � CiT FEDERAL WA BUILDING DEPT, POWER CABINET -ELEVATION AUXILIARY EQUIPMENT CABINET ULTRASITE MOUNTING PLINTH 2 ULTRASITE EQUIPMENT ISO 1 NOT TO SCALE 4 NOT 3 TO SCALE NOT TO SCALE NOT TO SCALE UMTS INDOOR DIMENSIONS MANUFACTURER: LUCENT HEIGHT: 74.02" DEPTH: 23.62" WIDTH: 2162" CLEARANCE: CABINETS REAR 0' CLEARANCE: CABINETS BOTH SIDE 0' CLEARANCE: CABINETS FRONT 36" MAXIMUM CABINET WEIGHTS: PRIMARY 006 LBS (275 KG) WEIGHTS: 3GP241 POWER 1060 LBS (481 KG) 2 Al 90A 4&Fa etT I MNEZMM1T.&M276 90&4zA6t.lm Woob MIAWAMM FAX- 4ite V9 noel M*=Mrivwgms DATE: MID-05 DRAWN BY: Ada CHECKED BY: I.fwo REVISIONS Dare oEsmmlw �UnriaL oeJJo Jos PIIEUM CM Are ssrssros zmmtnsuewr7a &Z JfJxz Jos FtlIAL C08 a.ls RY, 5Y• Q[ is RJHAL �`��yw EfRRES Q7115R7 SITE WA931 RANEN 30929 8TH AVE SOUTH FEDERAL WAY, WA 96DO3 SHEET TRLE EQUIPMENT SPECS _] SHEET NUMBER A-3.2 NOTES: 1 CONTRACTOR SHALL VERIFY THAT SOIL CONDITIONS ALLOW PERIMETER TRENCH TO FORM PERIMETER BEAM OTHERWISE OUTSIDE EDGE FORM WORK SHALL BE REQUIRED. DRAINAGE GRAVEL SHALL BE ADDED AFTER CONCRETE HAS ADEQUATELY CURED. 6" DEEP (2400 PSI - 5Yz SACK MIX) CONIC SLAB ON GRADE # 4 @ 18" OC EACH WAY - j Asa 6 MIL POLY .'• �,',•,���,,/, a a, 6" OF t11#4' MINUS CRUSHED ROCK (95 % COMPACTED) UNDISTURBED EARTH . DOWNTURNED SLAB , PERIMETER BEAM ##4 CLOSED STIRRUPS @ 76' ,•�;-fi��,- 1r OC 3' CLEAR MINIMUM 6" OF i%' MINUS CRUSHED ROCK (95 J % COMPACTED) EDGE OF CRUSTED ROCKSURFACE - COMPAC4TED ss�%ovEREWEEDCWRIERYER 6 MIL WEED BARRIER 2" OF 11M" MINUS UNDER LAYER ---\ 6- ENGINEERED FILL CMU BLOCK WALL SEE A-4 � 4" ABOVE GRADE GRADE DOWNTURN SLAB DEPTH FROM GRADE 24" (WESTERN WASHINGTON) 36- (EASTERN WASHINGTON) (4) ##4 @ 12- OC HORZ 3- CLEAR MINIMUM CONTINUOUS (SEE SLAB REINFORCEMENT PLAN) UNDISTURBED EARTH to EQUIPMENT SHELTER SLAB SECTION111 24"x36' SCALE: 1 if2'=1'-0" CRUSHED ROCK SURFACE DETAIL [-4 NOT TO SCALE e OY r uj 3- a w iv ."A @ 18- OC EACH WAY 3' CLEAR MIN r- r--r- I�r-r-r-�-T�TYT I I — I GEE CONCRETE NOTES 8 STRUCTURAL I I I I STEEL NOTES ON SHEET G•1 I a -I—I 1 I I— Ir——r--- r--r---r—--r r 114j-� f 1 1 1 1 1 1 1 1 1 it I r- ,-r--�---r-r-T-T-r-r-r--r-; -� 1 �I -I —I -f -I - r r r r r r-r--r-r--r--�: I-rWr-r- I !- I r EE —l--1 —1--j--I--�1 4" 4' 4" MIN MIN MIN SIDE SIDE SIDE 7' CABINET CABINET CABINET N I AK1iC E)CPANSIO 9 I I o .i�r r" iFltlA_ ( AJNSIO - raF�u� r -{yG}tA LTRASIT� rwciwct !NO ULTRA�IT tnarrEl r: POKIER CABINET !••••-C::_:•_- .� F !,f I IU FJ, r i I C,¢ fg. TC `+� I � in LL Q �{1N6i351 zw I �V I op I 3_� AUXILIARY ' 04 111 CABINET __-_--- -- -- 5 3'-114' 3' s CABINET 19 BUILDING/SLAB DOWNSPOUT 24'X12" SPLASH BLOCK (TYP _OF 2) COAX CABLE ENTRY �POI*T I I i I lz In I 1 EDGE OF DOWNTURNED SLAB 44 CLOSED STIRRUP @ 1W OC HOR2 3" CLEAR MINIMUM (4) ##4 @ 12" OC HORZ 3" CLEAR MINIMUM CONTINUOUS SLAB STEEL LAYOUT F n 24"x36" SCALE: i12'=1'-O' I V I E g 1 ul r z I o 1 ! E m I I I� ly In I I E`, Y I NOTE SHELTER USED FOR LAYOUT IS A 11'X19' CMU BUILT ON SITE - -I SHELTER. J lJ1 2 CITY OF FEDER EQUIPEMENT SLAB LAYF6 bl�I� 24'x36" SCALE: 1#2"=T-O' 2 0 U J C< W If L m w J w n ; V X �� COFIhIFs�•s-s'tyNe Na 20Q1}I6i"57R�c 31] RMi SEAE1.l17I BvL. gWeGf•►tlg4z DRAWN 8Y: Are CHECKED BY: rawo I we I CUCA01m, Imm I Rw W. vc aM1 v,$Mtn a� s~ mw �+6kVt Eti�� SITE WA931 RANEN 30929 BTH AVE SOUTH FEDERAL WAY, WA93003 �� !CONSTRUCTION TITLE CONSTRUCTION DETAILS L P SHEET NUMBER A-4 2 0 J C< W L C I c U x �aorw�a•'ra� tt7At11E=t V,WTE= RiMailS.1ra %DOWuawnteM roue 4MIM.irH otan: qomywgnHrq= DAIS: Do-tDas DRAWN BY: A/e CHECKED BY: Mwo REVISIONS DATE DESQtIPT" I m m 06/1a f05 PPEILl mS A.m us/ss ros zDrm�D avaurttu A.s 11132 /a5 YntAL GD9 AM ARK w. °is � OW ❑ a a s 'Pfur T$ EL•Ev %� EXP1RS6 01SID9 SITE WA931 RANEN 30929 BTH AVE SOUTH FEDERAL WAY. WA 98003 SHEET TITLE CONSTRUCTION DETAILS SHEET NUMBER A-4.1 1X6 PAINTED FASCIA MTL GUTTERS PAINTED TO MATCH TRIM ---� CINGULAR METER BASE & EMERGENCY GENERATOR RECEPTACLE , -- [NJ SPLASH BLOCK __'\ GPSIE9ll COMBINED ANTENNA --_ 1 4 SEEM NO •. 111mm ■—. limmi 3DO LB ASPHALT SHINGLE ROOF CMU BLOCK PAINTED 12 TO MATCH EXISTING 4 STRUCTURES ON SITE CINGULAR SIGNAGE (SEE DETAIL 9IA-5.1) (1) T-D' x 7'-0" DOORS PAINTED TO MATCH BUILDING INTAKE LOUVER (OPTIONAL) CONCFOUNDATION SPLASH BLOCK (NORTH SIDE ONLY) EQUIPMENT ENCLOSURE -WEST ELEVATION 24"x36" SCALE: 12'=1'-0" [ `+ GPS1E911 COMBINED 300 LB ASPHALT SHINGLE ROOF ANTENNA —� 1X6 PAINTED FASCIA TOP OF BUILDING l T-9- AGL TOP OF PLATE 9'A" AFS r— CMU BLOCK PAINTED TO MATCH EXISTING STRUCTURES ON SITE CINGULAR METER BASE & EMERGENCY GENERATOR RECEPTACLE SPLASH BLOCK (NORTH SIDE ONLY) TOP OF SLAB 4" AGL TOP OF GRADE 452.00' t AMSL HVAC UNITS CONC FOUNDATION EQUIPMENT ENCLOSURE -NORTH ELEVATION I L 24'x36' SCALE: 112"=1'-O" I L GPSIE911 COMBINED ANTENNA (OPPOSITE SIDE) MTL GUTTERS PAINTED TO MATCH TRIM --\ HVAC UNITS SPLASH BLOCK (NORTH SIDE ONLY) -- - COMBINED ANTENNA CINGULAR METER BASE &EMERGENCY GENERATOR RECEPTACLE 300 LB ASPHALT SHINGLE ROOF f— ix6 PAINTED FASCIA TOP OF BUILDING 72 11'-9" AGL _� 14 TOP OF PLATE 9-0" AFS CMU BLOCK PAINTED TO MATCH EXISTING STRUCTURES ON SITE CONC FOUNDATION SPLASH BLOCK (NORTH SIDE ONLY) TOP OF GRADE 462.00' t AMSL EQUIPMENT ENCLOSURE -EAST ELEVATION 3 24"x36" SCALE: 112"=1'-0" 300 LB ASPHALT SHINGLE ROOF iX6 PAINTED FASCIA HVAC UNITS 10W— CMU BLOCK PAINTED TO MATCH EXISTING 2 a U J G< Gp]�ni�LSTGNE cu�ll+emr+rsr"axle�o a>�ttsAmlra WWWaLF WAillM M +xAesral SuLl Esc_ DATE 06-1"S DRAWN BY: AM CHECKEDBY: iawo P� W, 0l q, a �iw�s omrs5�s SPLASH BLOCK (NORTH SITE SIDE ONLY) RECEIVE[ WA931 RANEN 30929 8TH AVE SOUTH FEDERAL WAY, WA 98003 JUN 2 5 2007 SHEET TITLE CONC FOUNDATION I CONSTRUCTION DETAILS CITY OF FEDERAL WAY EQUIPMENT ENCLOSURE -SOUTH ELMT11641- 24"x36" SCALE: 112"=l'-0" SHEET NUMBER A^4• • 2 BUILDING OVERHANG WALL MOUNTED UNISTRUT FOR COAX SUPPORT AT REAR OF CABINETS (TYP AS NEEDED) ,_ ------- -- - ---- --._--_----- -- �.� ■:im■■.■ ■. ■■ IN* ■■ ■■ ■■ ■■ Tie 1 � � i i ■■ ■■ ■■ ■ii t MEN ■■ ■■ ■■ ■ NOTE: ACCESSORY EQUIPMENT B==1SREQUIRED TO BE ONE HOU CEDAR SHAKE SHINGLES (ROOF COLOR TO MATCH MSTING ADJACENT BARN) FLASHING RAIN GUTTER W/ (2) DRAINS DOWN TO GROUND AT NORTH END OF BUILDING (SLOPE 1/4" PER FOOT) LEGEND: LIGHT -SURF. MTD. ON GYP. BD. CLG. 112 4 F'— lx8 CEDAR FASCIA CONVENIENCE OUTLET SURFACE MOUNTED GALV. RIGID CONDUIT & BOXES SWITCH SURFACE MOUNTED GALV. RIGID CONDUIT & BOXES REFLECTED CEILING PLAN 24"x36' SCALE: CMU BLOCK 13 CMU BLOCK NOTE: REFER TO SHEET S-1 FOR STRUCTURAL DETAILS (1) LAYER 518" TYP X GYP. 00. (TAPE AND SPACKLE) ON UNDERSIDE OF a2 NEW CEILING. PAINT WITH 2 COATS PRIMER AND INTERIOR OFF-WHITE LATEX PAINT. (518" (I)LAYER RESILIENT FLOORING; TARKETT GWB ARTFLEC" VCT-2 #221 a"CONCERT OFF WHITE SOLO OVER SEALED CONCRETE FLOOR PROVIDE 4" VINYL BASE: aARMSTRONG-CHARCOAL (1) LAYER 5/B" GWB GREY #14123. INTERIOR ONLY (2) T-7" (HOLLOW METAL LOCKING DOOR WITHIN STEEL FRAME). aKEYING SHALL BE COORDINATED WITH CINGULAR CONSTRUCTION COORDINATOR. ENLARGED EQUIPMENT ROOM FINISH PLAN 24"x36" SCALE: 318"=1' F3 NOTE: REFER TO SHEET S-1 FOR STRUCTURAL DETAILS NOTE: CONTRACTOR SHALL PROVIDE SEALED TRUSS SHOP DRAWINGS ON SITE FOR FRAMING INSPECTION. CEDAR SHAKE SHINGLES R-3D BATT INSULATION SEE DETAIL 1 � I lx8 CEDAR FASCIA BOARD & RAIN GUTTER W/(2) DRAINS DOWN TO GROUND AT NORTH END OF BUILDING (SLOPE 114" PER FOOT) PROVIDE 1-11Z"0 VENTILATION HOLES W/ BIRD BARRIER MESH AT 24" OC BUILDING SECTION 24"x36" SCALE: 318"=V-0' I ' R-30 BATT INSULATION CONCRETEFOOl%ffy OF FEDERAL VV CONCRETE FOOTING GFIDUPLEX RECEPTICLE (SEEDETAIL9&1uABUILDING DEPT. BUILDING SECTION 24"x36' SCALE: 3�8-=1'-O'f 2 0 U C< UJI U X �C6F1NEFl5"YC]hIC- �G ei.e nccn�no. �nc- 'a'KZ nIST, xa rkn AZARsrrz 5AL = DATE: as- o vs (DRAWN BY: rys CHECKED BY: mwo I REVISIONS I zolma ax Yl. aS 0 A E1CRRc3 Qyfl6� SITE WA931 RANEN 30929 8TH AVE SOUTH FEDERAL WAY, WA 98003 SHEET TITLE INTERIOR ELEVATIONS SHEET NUMBER A-4.3 5116"-18 HARDWARE rn NOTE: ALL CABLE TRAY MUST BE SOLID NOT TUBULAR 96 GROUNDING JUMPER SPLICE EXTENSION CLAMP (TYP. OF 4) SPLICE EXTENSION CLAMP KIT' INCLUDES: (2) RUNWAY CLAMPS AND 5116'-18 HARDWARE MATERIAL: ASTI"1 A570 STRUCTURAL STEEL FINISH: YELLOW ZINC DICHROMATE (YZN) SPLICE EXTENSION DETAIL 74 NOT TO SCALE Irr KIT.. HORIZONTAL TEE SPLICE DETAIL' NOT TO SCALE J-BOLTS (TYP. OF 2) INSTALL THREADED ROD PROTECTOR (TYP. OF 2) ALL THREADED ROD (TYP. OF 2) HARDWARE (TYP. OF 2) - HANGER SUPPORT (TYP. OF 2) 1WX2"X2" RUNWAY SUPPORT KIT: INCLUDES: (2) HANGER SUPPORTS AND HARDWARE MATERIAL: ASTM A570 STRUCTURAL STEEL FINISH: YELLOW ZINC DICHROMATE (YZN) RUNWAY SUPPORT DETAIL 3 NOT TO SCALE RUNWAY WALL SUPPORT KIT: INCLUDES: (1)ANGLE BRACKET, (2)J-BOLTS AND 5116"-18 HARDWARE MATERIAL- ASTM A36 STRUCTURAL STEEL ANGLE FINISH: TELCO GREY POWDER COAT 45 O U _.! C< W ry V x �CORNHR�Z'©NE nneu�nenlwa. IN=. itviIfZGfIi6F.5[%ii200 mm,,4a4uj ]i wxco attwAwn FAX 116tl1.qu wa.. ft*w wv*wrL= DATE: ns~ia DRAWN BY: ae CHECKED BY: r+wo ae no ray I FFEIIM LIIS _ I FA1 1 oer�e ros zalwa sumamu I am a�4o W. 0H C a r F a QISS fss�1. l L�pt" QPIfLS C711YA SITE wns31 RANEN 30929 8TH AVE SOUTH FEDERAL WAY, WA98003 v TIN 2 5 200 SHEET TITLE CONSTRUCTION DETAILS CITY OF FEDERAL BUILDING DEFT SHEETNUMBER RUNWAY WALL SUPPORT DETAIL A-4 A NOT TO SCALE 1 METAL STRAP SUBCONTRACTOR TO PROVIDE CNP) a• a ANT MHA BT5 NOTES: 1. MHA IS A WEATHERPROOFED ENCLOSURE RATED TO IP65. 2- BOND MHA GROUND STUD TO GROUND BAR WITH 6 AWG GROUND WIRE 3. PROVIDE SUFFICIENT LENGTH OF JUMPER TO ALLOW FOR PROPER APPLICATION OF WEATHER PROOFING AT ANTENNA AND MHA CONNECTIONS. 4. IF POSSIBLE, MHA SHALL BE MOUNTED BEHIND ANTENNA TO MINIMIZE WIND LOADING ON STRUCTURE. 5. MHA SHALL BE MOUNTED VERTICALLY. STUD SPACINI; TO MATCH COAX SUPPORT BRACKET 0 0 0 0 0 0 0 0 0 ANTENNA MOUNTING PIPE (TYP) MHA GROUND WIRE TO ANTENNA GROUND BAR FRONT VIEW I-L SIDE VIEW JUMPER TO ANTENNA GROUNDSCREW /-GROUND WIRE TO ANTENNA GROUND BAR (SEE NOTE 2) JUMPER TO MAIN COAX JUMPER TO ANTENNA METAL STRAP SUBCONTRACTOR TO PROVIDE (TYP) ANTENNA MOUNTING PIPE (TYP) ER TO COAX MHA DETAIL: .� NOT TO SCALE F(E)WATERTANK VALMONT B1588 W DOUBLE COAX SUPPORT KIT COAX SUPPORT BRACKET 24"x36" SCALE: 1 112'--V-0" COAX CABLE ROUTING ALONG THE WALL OF (E) WATER TOWER SEE 3 5 8 COAX CABLE, TYP (2) 4"0 PIPE BOLLARDS SEE e5_ GRADE (e) 6,0 PVC CONDUIT. REFER TO ELECTRICAL DWGS r VALMONT! MICROFLECT DOUBLE STACK COAX KIT B3099 3 (E) WATERTANK SHELL — COAX CABLE, TYP <9 COAX SUPPORT KIT 24'x36' SCALE: 1"=1'-D" COAX MOUNTING DETAIL 24"x36" SCALE:1"=1'-0' IL r r ANTENNA PIPE MOUNT OPTIONAL LOCATION OF MHA, AS PER SITE CONDITIONS !-\ PRIMARY MHA POSITION SEE 12/A-5 COAX TO JUMPER KIT. GROUNDING KIT AND CABINETS — is VALMONT I MICROFLECT 61 WI DOUBLE STACK COAX KI' CO WELDED 114• MOUNTING STUD WALL MOUNTED SUPPORT BRACKET (E) WATERTANK COAX CABLE, TYP NOTE: ANTENNA IS NOT SHOWN FOR CLARITY. r O.D. ANTENNA )NTING PIPE, TYP ENNA MOUNT ASSEMBLY WALMONT "82009") OF 2 LOCATION PER ENNA 3 CD WELDED THREAD D WI FLAT PLATE 3HER AT EACH SIDE HATER TANK SHELL. THICK Q ANTENNA ATION COAX SUPPORT KIT ANTENNA MOUNTING BRACKET DETAIL 24"x3B" SCALE: 3"-i'-D' I J I 24"x3B" SCALE: 2 ANTENNA AS PER ANTENNA SCHEDULE ANTENNA PIPE MOUNT COAXJUMPER SUPPORT MHA ATTACHMENT 24'x36" SCALE; 314"=T-W 1 1+ STAKE 114"0 CD WELD THREAD STUD AFTER INSTALLATION, TYP. 2'0 STD WT PIPE MAST (TYP) LENGTH TO SUIT ANTENNA MOUNTING HARDWARE (iOF ANTENNA ' EL: 86.8'J' AG.L: PANEL ANTENNA & DOWNTILT MOUNTING BRACKET. NSTALL PER MANUFACTURER'S RECOMMENDATIONS (E) WATER TOWER SITE WA931 RANEN VOTE: 30929 8TH AVE SOUTH ):� Ere f� � 4, F wd FEDERAL WAY, WA 98003 ANTENNAS A UN NG- ­IARDWARE SHALL BE PAINTED WITH A NON -REFLECTIVE RF SHEET TITLE fRANSPARCAV ,,{ IN12T15MTr7 E) WATER TA CONSTRUCTION DETAILS 2 0 V J CX u w L m w w w 3 co-�)m EIL37o^Gi NT 14MlN!M7rd t.WrrEmo "*4314 ara sm: momwa'.Ka= DATE' 0040.0 DRAWN BY: w+e CHECKED BY: hlwo Y w 0 +arm ExEy?F5 tt115sxs CITY OF FEDERAL WA i SHEET NUMBER ANTENNA MOUN-JUmSTAU' 'T- �_� 24' x36" SCALE: 1"=1'-Cr LOW HEAT CAPACITOR DISCHARGE STUD WELDING NOTES: ALL STUD WELDING ON WATER TANK SHALL BE A LOW HEAT CAPACITOR DISCHARGE {CD) STUD WELDING PROCESS IN CONFORMANCE WITH THE REQUIREMENTS OF THE AMERICAN WELDING SOCIETY ANSIIAWS 01.1 WELDING CODE CD STUDS SHALL BE 440 x 1 LONG LOW CARBON STEEL SMALL -FLANGED STUD. COPPER PLATED WITH UNC-2ASTANDADTHREADS. MAXIMUM FASTENING TORQUE = 43.0 INCH­LB.S ULTIMATE TENSILE LOAD =1750 LBS MAXIMUM SHEAR LOAD = 1300 LBS WATER TOWER SHELL MATERIAL IS A36 AND A573, GR 70 CARBON STEEL PLAT~ THICKNESS VARIES WITH HEIGHT FROM 1-INCH AT THE -TANK BOTTOM TO 114-INCH THICK AT THE TOP. TOP PLATE IS 0.32-INCH THICK A36 CARBON STEEL. ALL SURFACES RECEMNG STUD WELDING SHALL HE FREE OF PAINT, RUST MILL SCALE, GIRT. IADISURE AND ALL OTHER FORIEGN MATERIALS. ALL SURFACES SHALL BE TOUCHED UP WITH PAINT TO MATCH PASTING WITH THE APROVAL OF THE WATER DISTRICT REPRESENTATIVE. WELDING CONTRACTOR SHALL SUCESSFULLY WELD AND TEST TWO STUBS PRIOR TO PRODUCTION WELDING. TEST WELDS SHALL BE 13ENT TO 30-DEGREE ANGLE FROM THE WELD POSITION BY STRIKING WITH A HAMMER OR BENDING WITH APIPE. IF FAILURE OCCURS. RE-AWUST SETTINGS AND REPEAT TEST. ONCE THE SET-UP HAS BEEN APPROVED, PRODUCTION WELDING MAY BE STARTED, NO REVERSE SIDE MARKING IS PERMITTED. ALL WELDED CD STUDS SHALL BE VISUALLY INSPECTED 13Y OBSERVING THE RLLET AT THE BASE OF THE STUD FOR A FULL 360 DEGREE, EVEN WELD FILLET. CONTRACTOR SHALL TEST THREE STUDS EVERY HALF HOUR BY BENDING TO 15-13EGREES FROM THE BASE WELD POSITION TO ASSURE THAT THE SET-UP HAS NOT CHANGED OR IS SUITABLE TESTING SHALL BE CARRIED OUT AT THE BEGINNING OF EACH DAY, AFTER ANY CHANGE IN OPERATOR, OR IF THE SET-UP IS CHANGED IN ANY WAY. ALL WELDING SHALL BE PERFORMED BY WABO CERTIFIES WELDERS.. CAPACITOR DISCHARGE STUD WELDING NOTES 3 NOTE 1. FOR CINGULAR LOGO SEE CINGULAR LOGO DESIGN SPECIFICATIONS (PROVIDED BY CINGULAR) 1" 2. ALL TEXT FONT IS ARIAL U.N.O. 1q' 3, CONTRACTOR TO PROCURE FCC N0. FROM COMPLIANCE COORDINATOR PH: (425) 895-7000 — 2�l- 3116-0 SS THROUGH BOLT W/ 3" 0 SS WASHER OTHERSIDE, (4) PLACES V-4* T-2' 1" 11$' 14 53 Sq" 1/8" WIDE STRIPE - cj n- WIRELESS ' _ _ _RArnO 1ELLECDMMUHICAIION1 FACILITY atII ME- K.NKAa94. LKN_F24 NCG5481 A C 8,' CONTACT Rit-SOM32-6582� — — — — 1 1 t- 1/4" f O 7CASINPT 1TEXT FOR SIGNAGE SHALL INDICATE CORRECT SITE NAME AND NUMBER AS PER CINGULAR CONSTRUCTION MANAGER RECOMMENDATIONS 2. CABINET MOUNTING APPLICATION REQUIRES ADHERING PLATE TO FACE OF WITH WATERPROOF POLYURETHANE ADHESIVE FINISH GRADE 12"6 CONCRETE BASE - FABRIC FENC� APPLICATION CINGULAR SIGNAGE DETAIL NOT TO SCALE 4"0 SCH 40, STEEL PIPE. FILL WITH CONCRETE AN[ PAINT CAUTION YELLOW. I ]I =— C 1E7 —1 ,III 1r I4� 4 m rN m� N 'Al. JUN 2 5 2007 CITY OF FEDERAL PIPE BOLLARD DFXIL 2036 SCALE: 112"=l'-O' I 1 2 0 U J G< W of V X tivllTc?7TRI+?,SIAfEZd FIgILFCS.g1.si>? 8'tlOCPi5411;1W199PFt FAX TY iR.fl3l 8411. aap�n DATE: 0s.10-m DRAWN BY: and CHECKED BY: mwo I minim I ZOMIGBUSWrru I AA I W. a oyns• i P n �T3+o MAL psv,�s cari,ca SITE WA931 RANEN 30929 BTH AVE SOUTH FEDERAL WAY, WA 98003 L SHEET TITLE CONSTRUCTION DETAILS SHEET NUMBER A-5.1 INSTALLATION VIEW INSTALLATION NOTES: 1. CONTRACTOR SHALL PULL COAX CABLES THROUGH CONDUIT. 2, CONTRACTOR SHALL BRING H-SERIES SEAL ADJACENT TO COAX CABLES AND CAREFULLY UNSCREW METAL PLATES FROM ASSEMBLY. 3. CONTRACTOR SHALL REMOVE CENTER CORE FROM ROXTEC GASKET ASSEMBLY AND CONTINUE PULLING AWAY EACH CIRCULAR RUBBER LAYER AWAY FROM ASSEMBLY UNTIL OPENING FITS DIAMETER OF COAX. 9. CONTRACTOR SHALL REPEAT ITEM 3 FOR ALL COAX CABLES AND REASSEMBLE RUBBER GASKET AROUND ALL THREE BY COMBINING STEEL PLATES AND SCREWING PLATES TOGETHER (LEAVE APPROXIMATELY 1mm OF SPACE IN COMPRESSION RING SUCH THAT WHEN COMPRESSION OCCURS IT WILL GRPATEATIGHTSEAL). 5. PRIOR TO FULL ASSEMBLY, CONTRACTOR SHALL LIGHTLY LUBRICATE BOTH COAX CABLES AND INSIDE SURFACES OF RUBBER GASKET COMPRESSION RINGS WITH MANUFACTURE SPECIFIED LUBRICANT, 6. PRIOR TO FINAL TIGHTENING OF BOLTED CONNECTIONS, CONTRACTOR SHALL INSERT SEAL ASSEMBLY INTO PVC CONDUIT NEAR OPENING. 7. CONTRACTOR SHALL PROCEED TO TIGHTEN BOLTED CONNECTIONS UNTIL SEAL ASSEMBLY 15TIGHTLY FITTED WITHIN CONDUIT (CONTRACTOR SHALL CONFIRM THERE ARE NO GAPS IN-BETWEEN SEALS), 8. INSTALLATION NOTES ALSO APPLY TO COAX CABLES EXITING CABINETS AND COAX PORTS. ROXTEC INTERNATIONAL AB Anx w usn 11 rwwrra Iffl Ran H SEAL H3-15013X(28- MnO LA RARA 1. SIGNS & PLACEMENT A, LOW LEVEL (BLUE) WARNING SIGNS - PLACE AT SITE ENTRY/ACCESS POINTS ONLY: ROOF TOPS: PLACE SIGNS ON THE INSIDE OF ROOF HATCH: CONDUIT EXIT SEAL PLACE ON ACCESS DOOR UNLESS DOOR IS USED BY GENERAL PUBLIC OR BUILDING TENANTS REGULARLY FOR ACCESS - IN THESE CASES CONSULT CONSTRUCTION MANAGER OR CC SUPERVISOR WATER TANKS: PLACE SIGNS ON COMPOUND GATE CINGULAR-OWNED SITES: PLACE ONE SIGN ON SITE GATE B. ALL SIGNS WILL BE SECURED WITH EITHER STAINLESS STEEL ZIP TIES OR STAINLESS TECH SCREWS 2, CC PARTICIPATION IN SIGN LOCATION CM WILL MEET WITH ALL CC'S TO OUTLINE CRITERIA FOR SIGN PLACEMENT; EMPHASIS WILL BE OWGRAY AREA' SITES, WHERE SIGN PLACEMENT IS PARTICULARLY CHALLENGING- WE WILL 6"0 COAX CONDUIT GIVE CC'S AS MUCH GUIDANCE ON SPECIFIC SITUATIONS AS WE CAN FORESEE, BUT CC'S WILL BE ENCOURAGED TO PARTNER CM OR OC IN DECIDING PLACEMENT OF DIFFICULT SITES. A JOINT SITE VISIT MAY BE REQUIRED TO FULFILL REQUIREMENTS CC WILL CALL OUT SIGN LOCATION(S) AT THE A&E WALK FOR EACH SITE AS THOSE OCCUR ON SITES WITH EXISTING A&E BUT NOT YET CONSTRUCTED, CC WILL BE ASKED TO PROVIDE (WITHIN A REASONABLE TIME FRAME TBD) A DETAIL FOR SIGN PLACEMENT THAT WILL BE SLIP -SHEETED INTO EXISTING SETS 3- SIGN DISBURSEMENT FROM WAREHOUSE SIGNS WILL BE IN STACK AT KENT WAREHOUSE TO BE DISBURSED AS PART OF THE GC BCAI AS CALLED OUT IN A&E DRAWINGS FOR EACH SITE 1- pj) 4' [20.001 [moo COAX CONDUIT EXIT SEAL F-3 NOT TO SCALE NOTICE Beyond this point you are entering an area where RI= Emissions may exceed the FCC General Population Exposure Limits Follow all posted signs and site guidelines for working in an RF environment Ref: FCC47CFR 1,177(b) Cb pLu M.I.s RECEIV JUN 2 5 CITY OF FEDE' BUILDING DI. RF WARNING SIGNAGE NOT TO SCALE 2 O U J Ct W / � [.L U X EED-1 earMpa<IMw, f11 o.. 1=W_2 MFr,9M2M ME1i5ABl.1n21 WDMWLL£,WAW2 FAit {25AW_1731 MAL ASO iDATE: Ob10-05 ,DRAWN BY: A s CHECKED BY: Mtvo REVISIONS GATE Oli9d11P110N [N RIAL 00l10 . PRELG Cp9 AJO U126105 I ZONMG SUBMIrrAL I AM 11,22105 i FN/AL COS IJ0 Rx w• nr t cr y 4 �o� eQ1,S�7FX+Q,t� ss P"L & SXRr--5 imlw SITE WA931 ~I RANEN 30929 8TH AVE SOUTH FEDERAL WAY, WA 98003 SHEET TITLE ]qXON$TRUCTION DETAILS SHEET NUMBER A-5.2 RECEIVE'.- JUN 2 5 20D7 CITY OF FEDERAL % BUILDING DEPT 2 Al U CX w w �COF ram: -✓✓NE fiNiiE mi]i5T.91RE 7A R1Pt�eaAdi.Ttt! M;L mo.., s W= DATE: na-fo-0s DRAWN BY: aie CHECKED BY: tawo REVISIONS I MING AK SY. R X=4rs° toW Sum E1epL�lE5 mm% SITE WA931 RANEN 3D929 8TH AVE SOUTH FEDERAL WAY, WA 98003 SHEETTITLE RADIO PLAN SHEET NUMBER A-6 CABLE MARKING TAGS SWEEP TEST REWREMENTS: CINGULAR WIRELESS SEATTLE, WA. ANTENNA AND TRANSMISSION LINE TEST REQUIREMENTS REOUIRED_E0 lPMEKT 1 WILTRONIANRITSU SITE MASTER S331AIBIC OR EQUIVALENT. 1 OPEN, SHORT, LOAD. I DIN FEMALE TO N TYPE MALE ADAPTER (LOW LOSS). 1 DIN MALE TO N TYPE MALE ADAPTER (LOW LOSS)- 2 DIN FEMALE TO DIN FEMALE ADAPTER (LOW LOSS). 1 PHASE STABLE CABLE. 1 TRUE-RMS MULTI -METER. FR Q ENCIE5T B USE PCS FREQUENCY BAND 185OMHZ-1990MRZ TRANSMIT FREQUENCY 1930MHZ-194OMHZ RECEIVE FREQUENCY 1B59MHZ-1860MHZ T ION LINE AND ANTENNA YS Di T (1) INSERTION LOSSICABLE LOSS (2)ANTENNAITRANSMISSION LINE DISTANCETO FAULT (RL) (3) ANTENNA SYSTEM RETURN LOSS (4) ANTENNA SYSTEM WITH DUPLEXERITMAIANTENNA RETURN LOSS (5) TRANSMISSION LINE CONTINUITY TEST INSERTION LOSS_ THIS TEST WILL MEASURE THE CABLE LOSS OF THE TRANSMISSION LINE AND JUMPERS BETWEEN THE CABINET AND ANTENNA. TEST FREQUENCIES: F1=1850 F2=1990 1, ENTER THE FREQUENCIES TO BE USED IN Ft AND F2. 2. RE -CALIBRATE TEST EQUIPMENT. 3. CONNECT THE TWO JUMPERS GOING TO THE ANTENNA(BYPASS TMA) AND THE CABINET (BYPASS DUPLEXER) USING THE DIN (F) TO DIN (F) CONNECTORS. 4. CONNECT A SHORT AT THE END OF THE LAST JUMPER BEFORE THE ANTENNA, OF THE LINE UNOER TEST, 5. CONNECT TEST EOUIPMENT TO THE LAST TX JUMPER (YELLOWIRED) BEFORE THE CABINET. OF THE UNE UNDER TEST. 6. PERFORM MEASUREMENT, THEN DUE STEPS 10 THROUGH 12. 7_ DISCONNECT TX JUMPER, THEN CONNECT THE RXJUMPER (YELLOWIGREEN) TO DIN (F) ADAPTER 8, CONNECT TEST EQUIPMENT TO THE LAST RX JUMPER (YELLOWIGREEN) BEFORE THE CABINET, OF THE LINE UNDER TEST S. PERFORM MEASUREMENT, THEN DUE STEP i0 THROUGH II 10- ADD THE MAXIMUM PEAK TO THE MINIMUM VALLEY THEN DIVIDE BY TWO. THIS IS THE CABLE INSERTION LOSS. THIS VALUE SHOULD NOT BE GREATER THEN 4DB. 11. PEAK MAX (M1) + VALLEY MIN (M2N2= CABLE INSERTION LOSS. 12. RECORD CALCULAT60IMEASURED VALUE ON SWEEP DATA SHEET. THEN SAVE SWEEP TO A MEMORY LOCATION. 13. REPEAT STEPS 1 THROUGH 12 FOR THE REST OF THE TRANSMISSION LINES. AIVt NNIAITRANSMI I N I DIST ETOFA L7 RL' THIS TEST IS APERFORMANCE VERIFICATION AND FAILURE ANALYSIS TOOL FOR THE ANTENNA.7RAN SMISSIONIINSS AND CONNECTORS, TEST FREQUENCIES: F1=1850 F2=1990 1. ENTER THE FREQUENCIES TO 13E USED IN Ft AND F2, 2. RE -CALIBRATE TEST EQUIPMENT. 3. CONNECT THE TWO JUMPERS GOING TO THE ANTENNA (BYPASS TMA) AND THE CABINET (BYPASS DUPLEXER) USING THE DIN (F) TO DIN (F) CONNECTORS. 4. CONNECT THE ANTENNA TO THE LINE UNDER TEST. 5. CONNECT TEST EQUIPMENT TO THE LAST TX JUMPER 6. PERFORM MEASUREMENT. VER FINET, OF THE LI NE UNDER EST. Y RESULTS WITH STEPS 40 THROUGH 13. T DISCONNECT TX JUMPER, THEN CONNECT THE RX JUMPER (YELLO W IGREEN) TO DIN (F) ADAPTER 8. CONNECT TEST EQUIPMENT 70 THE LAST RX JUMPER (YELLOWIGREEN) BEFORE THE CABINET, OF THE LINE UNDER TEST_ 9. PERFORM MEASUREMENT. VERIFY RESULTS WYTH STEPS 10 THROUGH 13. 10, VERIFY EACH DIN CONNECTOR HAS A RL LESSTHEN -32DB, N TYPE -2800, 11. VERIFY THE TRANSMISSION LINE HAS A RL LESS THEN A08. 12. VERIFY THE ANTENNA HAS A RL LESS THEN -17DB. 13. RECORD PASSIFAIL ON SWEEP DATASHEET, THEN SAVE SWEEP TO A MEMORY LOCATION. 14. REPEAT STEPS I THROUGH 13 FOR THE REST OF THE ANTENNAS AND TRANSMISSION LINES ANT6NTE9NA SYKE!AR9aQ!5_NlD-%%L- THfSTEsT MEASURES THE RL OF THETRANSMISSION LINE TERMINATING INTO THE ANTENNA WITHOUT THE TMA AND OUPLEXER. TEST FREQUENCIES: F1=1650 F2=1990 1, ENTER THE FREQUENCIES TO BE USED IN Fl AND F2. 2. RE -CALIBRATE TEST EQUIPMENT, 3. CONNECT THE TWO JUMPERS GOING TO THE ANTENNA (BYPASS TMA) AND THE CABINET (BYPASS DUPLEXER) USING THE DIN (F) TO OIN (F) CONNECTORS. 4. CONNECT THE ANTENNA TO THE LINE UNDER TEST. 5. CONNECT TEST EQUIPL41FNT TO THE LAST TX JUMPER (YELLOWIRED) BEFORE THE CABINET, OF THE LINE UNDER TEST. G. PERFORM MEASUREMENT. VERIFY RESULTS WITH STEPS 10 THROUGHI3. 7. DISCONNECT TX JUMPER, THEN CONNECTTHE RX JUMPER (YELLOWIGREEN) TO DIN (F) ADAPTER 8 CONNECT TEST EQUIPMENT TO THE LAST RX JUMPER (YELLOWIGREEN )BEFORE THE CABINET, OFTHE LINE UNDER TEST 9. PERFORM MEASUREMENT. VERIFY RESULTS WITH STEPS 10 THROUGH 13. 10. VERIFY ANTENNA SYSTEM USING 1 518' WAVE -GUIDE HAS A RL LESS THEN -17DB, 20DFT MAX. 11. VERIFY ANTENNA SYSTEM USING 718" WAVE -GUIDE HAS A RL LESS THEN -16DB, 20OFT MAX- 12. FOR SYSTEMS ABOVE 20OFT 1 518" RL-15.5DB, 718" RL -14DB. 13. RECORD TEST RESULTS ON SWEEP DATA SHEET, THEN SAVE SWEEP TO A MEMORY LOCATION. 14, REPEAT STEPS 1 THROUGH 13 FOR THE REST OF THE ANTENNA SYSTEMS. ex TE IA SYSTEM WIT GUPLEXER ANOTMARETURN LASS: THIS TEST MEASURES THE RL OF THE COMPLETE ANTENNA NETWORK ON TFIE TX PATH. TX TEST FREQUENCIES: Fi=1930 F2=1940 1. ENTER THE FREQUENCIES TO BE USED IN Fi AND F2. 2. RE -CALIBRATE TEST EQUIPMENT 3. REMOVE DIN (F) TO DIN (F) FROM BOTH TOP AND BOTTOM JUMPERS. 4. CONNECT TOP JUMPERS TO TMA AND CONNECT BOTTOM JUMPER TO DUPLEXER. 5. CONNECT TEST EQUIPMENT TO TX i (YELLOWIRED). 6. PERFORM MEASUREMENT. 7. VERIFY ANTENNA NETWORK USING 1 518" WAVE -GUIDE HAS A RL LESS THEN-15.51313, 200FT MAX. 8. VERIFY ANTENNA NETWORK USING 71V WAVE -GUIDE HAS A RL LESS THEN-14.5DB, 20DFT MAX. 9, FOR ANTENNA NETWORK ABOVE 200FT 1 5I8" RL-14DB, 718" RL-12.5DB. 10- RECORD TEST RESULTS ON SWEEP DATA SHEET, THEN SAVE SWEEP TO A MEMORY LOCATION. 11. REPEAT STEPS 1 T HROUGH 10 FOR THE REST OF THE TX ANTENNA NETWORKS. ANTENNA SYSTEM WITH ❑UPLEXER AND TMA RETURN LOSS: THIS TEST MEASURES THE RL OF THE COMPLETE ANTENNA NETWORK ON THE RX PATH, REMINDER THE TEST EQUIPMENT WILLTE RMI MATE INTO THE TMA ON THE RX PATH, RX TEST FREQUENCIES: F1=1650 F2=1860 1. ENTER THE FREQUENCIES TO BE USED IN F1 AND F2. 2. RE -CALIBRATE TEST EQUIPMENT 3. REMOVE DIN (F) TO DIN (F) FROM BOTH TOP AND BOTTOM JUMPERS. 4. CONNECT TOP JUMPERS TO TMA AND CONNECT BOTTOM JUMPER TO DUPLEXER. 6. CONNECT TEST EQUIPMENT TO RX 1 (YELLOWIGREEN). 6. PERFORM MEASUREMENT. 7. VERIFY ANTENNA NETWORK USING 1 518" WAVE -GUIDE HAS A RL LESS THEN-16.SDB, 200FT MAX. B. VERIFY ANTENNA NETWORK USING 7/8"WAVE-GUIDE HAS A RL LESS THEN-15.5DB. 200FT MAX. 9. FOR ANTENNA NETWORK ABOVE 20OFT 1 518" RL-14DB, 7l8" RL .13.50B. 10. RECORD TEST RESULTS ON SWEEP DATA SHEET, THEN SAVE SWEEP TO MEMORY LOCATION. 11. REPEAT STEPS 1 THROUGH 10 FOR THE REST OF THE RX ANTENNA NETWORKS. TRANSMISSION LINE CONTINUTTYTEST: THIS TEST WILL VERIFY THE CONTINUITY OF THE RX PATH BETWEEN THE BTS AND THE TMA FOR THE 15 VDC NETWORK. 1. CONNECT A SHORT AT THE END OF THE LAST JUMPER BEFORE THE TMA. OF THE LINE UNDER TEST, 2 CONNECT MULTI -METER TO LAST JUMPER BEFORE THE BTS, RX 1 (YELLOWIGREEN). PLACE THE BLACK LEAD ON THE OUTER PART OF THE CONNECTOR AND THE RED LEAD ON THE CENTER PIN OF THE CONNECTOR. 3. VERIFY THE METER READS A SHORT. 4. REMOVE SHORT AND VERIFY METER READS OPEN. 5. RECORD PASSIFAIL ON SWEEP DATA SHEET. 6. RE -CONNECT JUMPERS TO TMA AND BTS. 7. REPEAT STEPS I THROUGH 6 FOR THE REMAINING RECEIVE PATHS, NOTE: EDIT AND SAVE ALL SWEEPS TO A 3.5' DISKETTE AND EMAIL SWEEPS TO JAMI=S,FUGATE@CINGULAR.COM PROVIDE A COPY OF ANTENNA SYSTEM TEST RESULTS WITH DISKETTE ON FINAL SITE WALK. QUESTIONS CONTACT: JAMES FUGATE 208-240-9006 M HA (TYP) TOPJUMPE REQUIRED) GROUND W NEAR ANTE GROUNDIN( MAIN COAX CABLE [TYF GROUND BD NEAR EQUIF BOTTOM JL ANTENNA ANTENNA ANTENNA UMTS UMTS MHA (TYP) TOP JUMPER CABLE (IF REQUIRED) GROUND BAR NEAR ANTENNAS GROUNDING KIT TO PROVIDE ADDITIONAL IDENTIFICATION EACH RF CABLE SHALL BE IDENTIFIED WITH A METAL TAG MADE OF STAINLESS STEEL OR BRASS AND STAMPED AS SHOWN. THE ID MARKING LOCATIONS SHOULD BE AS PER'CABLE MARKING LOCATIONS TABLE'. THE TAG SHOULD BE ATTACHED WITH CORROSION PROOF WIRE AROUND THE CABLE THE FOLLOWING ARE 3 DIFFERENT FORMATS TO BE USED FOR THE BRASS TAGS. o a o yp lA IA T8 3B G9LI9 FORMATA FORMAT B FORMAT C t AM OF AT FORMAT A IS USED WHEN THERE IS ONLY ONE TECHNOLOGY BEING CARRIED ON A CABLE. FORMAT B IS USED WHEN TWO TECHNOLOGIES HAVE BEEN DIPLEXEO ONTO ONE CABLE AND WILL BE BROKEN OUT THROUGH A DIPLEXOR ATTHE TOP OF THE TOWER. FORMAT C IS USED WHEN TWO TECHNOLOGIES HAVE BEEN QUADRAPLEXED ONTO ONE CABLE FORANTENNAPORT SHARING AT THE TOP OF THE TOWER. THE FIRST NUMBER DESIGNATES THE ANTENNA POSITION, THE SECOND CHARACTER DESIGNATES THE PORT ON THE ANTENNA, THE THIRD CHARACTER DESIGNATES THE TECHNOLOGY TYPE, AND THE LAST NUMBER DESIGNATES THE FREQUENCY BAND OF THE TECHNOLOGY. Bi SECTORI SECTOR2 RF CABLES A2 RF CABLES B2 THRU A5 AS THRU BB AS RE4O REOD AI � Cl SECTOR 3 RF CABLES C2 THRU CG AS RECTO NOTE: SECTOR ORIENTATIONIAZIMUTHAfILL VARYFROM REGION TO REGION AND IS SITE SPECIFIC. REFER TO RF REPORT FOR EACH SPECIFIC SITE TO DETERMINE THE SECTOR ORIENTATIO14 ALL RF CABLE SHALL BE MARKED AS PER CABLE MARKING rnw I... rCGI nlw CABLE MARKING LOCATIONS NO- TAG I LOCATIONS 1 X END OF THE MAIN COAX RUN WHERE THE COAXIAL CABLE AND JUMPER TO THE ANTENNA ARE CONNECTED, 2. X CABLE ENTRY PORT ON THE INTERIOR OF THE SHELTER (AS APPLICABLE). 3. X END OF JUMPER AT BTS CABINET GROUND BAR CABLE COLOR MARKING NEAR EQUIPMENT IN ADDITION TO THE IMPLEMENTATION OF BRASS TAGS, CONTRACTORS SHALL USE ONE BAND OF COLOR TAPE PER CABLE FOR SECTOR DESIGNATION LABELING, THE COLORS SHALL BE AS FOLLOWS: SECTOR A: RED SECTOR B: BLUE SECTOR C. GREEN THE SECTOR DESIGNATIONS SHALL BE MARKED (AS• DESPRiq$Di BOTTOM JUMPER CABLE ON THE CURRENT RF DATASHEET (RF DS)ATIYTIi(EO - C L jV INSTALLATION. RF DATASHEET IS TO REMAIN POSTED AT EVERY SITE COAX BOOT SPECIFICATION IUN 2 5 2007 UMTS ENTRY BOOTS TO SEAL COAX WITHIN 6" CONDUITS SHALL BE: CABINET ROXTECHSEAL A `Tyy ��FF DERAL WA� H3-15013X(28-54)120 SEE COAX CONDUIT EXlls sw E' (WHEN APPLICABLE) BUILid1 G, DEPT. CONTRACTOR SHALL USE THE ABOVE PRODUCTS OR APPROVED EQUAL _ 2 0 U C< w W 1 C-9) q i�L5TC7 ' Na,H¢¢¢lr.oH . I c. "OX01 "w0m r* OSI31.11N 5AL, rdgmm¢ wffww DATE: aB-saos DRAWN BY: Ara CHECKED BY: PRELIM MS FINAL WA ng P a JSiv 4 as10flRi 61iG flrPIR¢S R7Jii96 SITE WA931 RANEN 30929 STH AVE SOUTH FEDERAL WAY, WA 98003 SHEET TITLE ANTENNA SWEEP TEST 8 COAX COLOR CODING SHEET NUMBER A- ■MB Ho Coverage ❑ Poor outdoor Coverage ® Out,door Coverage ❑ Vehicular Coverage ® Indoor Coverage Existing_Blue_Sites A Kee per_Blue_Sites •I Existing_Orang e_Sites Ieeper_Orange_Sites Proposed_Oual_Sites 0 Current Drive Test Data For WA931 (SS62)— %t�� I� 4 p I I IL Ukkk - � 1 i � I � I �A r ti -41 � .. .VIECEIVED J ! N 2 5 2007 II.i rITY OF FEDERAL WAY BUILDING DEPT. Coverage Prediction without WA931 (SS62 Pi 1pff -M FLV F-1 "o Coverage ❑ Poor qatrwoor Coverage out(loor Coverage ❑ Vehicular Coverage ■ Indoor Coverage N.,.I / I- 71 'UN 2 5 2007 ITY OF FEDERAL NA/A',,' BUILDING DEPT. 0 ❑ Ho Coverage ❑ Poor Outcloor Coverage Q oumoor coverage ❑ Vehicular Coverage 0 Indoor Coverage Coverage Prediction with WA931 (SS62) ■ * WA►677-R.9