16-102562 (2)55'
1
PLOT PLAN
SCALE: 1" = 10'-0" o
SW 314TH ST.
246'
\ \--_____\1/
2g 88 -.33'
-4.5'
F"
N
5,
LEGEND:
(E) WALL TO REMAIN
= _ = DEMO (E) WALL
(N) WALL
TAX ACCOUNT NUMBER
1503100140
LEGAL DESCRIPTION
CENTURY PALASIDES #1 CORREC PLAT
BUILDING HEIGHT
BASE HEIGHT:
+9'-6"
PITCHED ROOF:
+4'-1"
TOTAL ALLOWABLE:
+35'
PROPOSED:
+13'-7"
LOT COVERAGE
SITE AREA: 10,953 SF (ACTUAL)
(E) HOUSE : 2,208 SF
TOTAL: 2,208 SF (20%)
WINDOW DOOR SCHEDULE
MARK
SIZE
TYPE
WINDOW TYPE(S)
GLAZING
(EA)
#
GLAZING
AREA
(TOTAL)
FINISH
GLAZING
U
AVG.
MANUFACTURE
NOTES
4o4o
SLDR
GLASS WINDOW
16
5
80
VINYL
DOUBLE, LOW-E4, 1 /2"
MILGARD
2o2o
SLDR
GLASS WINDOW
4
2
8
VINYL
DOUBLE, LOW-E4, 1/2"
MILGARD
TOTAL GLAZING AREA
88
PRESCRIPTIVE REQUIREMENTS APPROACH:
GROSS (HEATED) FLOOR AREA: 756 SF EXTER, WALLS:
TOTAL GLAZING AREA (PROPOSED): 88 SF (11.6 %) ROOF/CEILING:
FLOOR :
GLAZING:
PROJECT INFORMATION EXTERIOR DOORS:
PROJECT TITLE: CONVERSION OF (EXISTING GARAGE TO BEDROOMS
SINGLE FAMILY RESIDENCE PER PLAN.
SITE ADDRESS: 2704 SW 314TH ST.
FEDERAL WAY, WA. 98023
PARCEL NUMBER:
DISTRICT:
TELEPHONE:
1503100140
KING COUNTY
ANTHONY WANJIKU
206-335-1351
R-21 R-38 (ATTIC) IF vaa � ���� - Lio� 'f � �'O-f
R-30
U= 0.40 MAX.
U= 0.40
2012 IRC R109.4 Approval Required
Work shall not be done beyond the point indicated in each
successive inspection without first obtaining the approval of the
building official. The building official upon notification shall
make the requested inspections and shall either indicate the
Portion of the construction that is satisfactory as completed or
shall notify the permit holder or an agent of the permit holder
wherein the same fails to comply with this code Any portions
that do not comply shall be corrected and such portion shall not
be covered or concealed until authorized by the building
official.
GENERAL NOTE:
1 • CONTRACTOR TO NOTIFY DESIGNER OF ANY DESCREPANCIES DISCOVER ON PLANS AND SITE
PRIOR PROCEEDING ANY WORK.
2. ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE
CITY OF SEATTLE AND LATEST EDITION OF UNIFORM BUILDING CODE AND THE WASHINGTON
ENERGY CODE.
3• WHEN WORK NOT SPECIFICALLY CALLED OUT AND IS REQUIRED TO COMPLETE THE PROJECT, IT
SHALL BE OF THE BEST MATERIALS AND WORKMANSHIP.
ANY CODE SECTION NOT
MENTIONED IN THIS REVIEW
DOES NOT IMPLY THAT A CODE
IS NOT REQUIRED OR WAIVE A
CODE WIREMENT
[A] 105.4 Validity of permit.
The issuance or granting of a permit shall not be construed to be a
permit for, or an approval of, any violation of any of the provisions
of this code or of any other ordinance of the jurisdiction. Permits
presuming to give authority to violate or cancel the provisions of
this code or other ordinances of the jurisdiction shall not be valid.
The issuance of a permit based on construction documents and
other data shall not prevent the building official from requiring the
correction of errors in the construction documents and other data.
The building official is also authorized to prevent occupancy or use
of a structure where in violation of this code or of any other
ordinances of this jurisdiction.
mVeD
MAY 2 6 2016
CITY OF FEDERAL `JtlAY
CDS
SHEET NUMBER
0 -0 D
D 70 0
rn O 7
MM
44