Loading...
20-102489-Project Narrative-2020-05-29-V1 May 29, 2020 – Response 1 to agency comments Pape Kenworth Northwest NE Corner I-5 and 320th Street Federal Way, WA COMMUNITY DESIGN GUIDELINE NARRATIVE:   FWRC 19.115.010(2) - CPTED - Crime Prevention thru Environmental Design Principles: Refer to the “Crime Prevention thru Environmental Design Principles (CPTED) Checklist” attached to this submittal package. It will cover natural surveillance, Access Control, Ownership issues. STATEMENT OF ARCHITECTURAL DESIGN INTENT: The proposed project is a large industrial facility that is located within the BC, Community Business Zone. The use is ”Truck sales, service and repair” business and is an approved outright use . The gross land area is 21.43 Acres and if removing the areas for public dedication, critical areas or retention/detention areas, the net land area is 13.66 acres, a reduction of 7.77 acres or we might say 63% usable land area. In addition to this, we have the BPA overhead transmission easement and this further encumbers the site whereby no building structures can occur below the easement lines. The easement occupies about 4.15 Acres in addition to the above encumbrances, reducing the “buildable” land area to 9.51 acres or we might say 44% net buildable land area. The area under the easement can be used for vehicle parking, so this particular use takes advantage of the site restrictions and will fit well within this area of the city. The site will have large expanses of paved surfaces to accommodate 63-68’ long trucks (cab length 23- 25’, trailer length 40-43’). There will be large turning radii required to accommodate these trucks, in addition to garbage and fire truck access. In addition, the site is considered “hilly” and with trucks that tow what is referred to as “low boy” trailers, the surface of the pavement is sensitive to grade changes that could cause the trailers to scrape the pavement. These low boy trailers sit 6-7” above the road surface so the heavy equipment center of gravity stays as low as possible. The site was re-graded relatively flat with uniform slopes for this reason. The building will be composed of warm, earth tones (bronze brown and pewter accent) colors. There will be two buildings onsite; Building A along north side of the site for the Kenworth office/showroom and maintenance shop; Building B, at the southeast corner to house body shop bays. The buildings will have a split-faced CMU wainscot to 3’4” above finished floor. The body of the buildings will have a textured insulated metal siding or smooth-faced insulated metal panels as shown on the material sample board and exterior elevations. The primary body, metal trim, doors, storefront, Pape Kenworth NW Design Guidelines May 29, 2020 Page 2 canopies will be dark bronze brown and highlight entry feature will be a metallic gray with a yellow horizontal accent stripe on both buildings. Additional building signage will be added to the elevations to express entry. The showroom will have full height glass on south and east walls and will have an overhead door to allow a Kenworth truck cab to enter and park for advertising within the showroom. The trash enclosures will be constructed out of split-faced cmu block to match the building. The gates will have steel structure with a textured metal siding to match the building body. Dark brown coping and metal gates will match the building. Large expanses of the building will be broken up with these horizontal lines that are separated by material, color or textural changes. End Statement of Architectural Design Intent FWRC 19.115.050 - SITE DESIGN (1) General Criteria: (a) Natural Amenities: Subject site layout has been heavily influenced by Bonneville Power Administration (BPA) power lines and easements along the south side of the site. The large easement bisects the site in a northeasterly angle as shown on the site plans. The building layouts and grades were dictated by this massive easement. Along the west side, there are varying degree of slopes and at the bottom of this are wetlands that are designated on the site plan. The wetland and buffers will be retained as a natural amenity and would be visible from both I-5 and from the site. Within this naturally occurring landscaped area are groupings of both evergreen and deciduous trees. Although we show a buffer reduction of 951 sf, there is a buffer addition of 1,422 sf along the west side of building A. (b) Pedestrian Areas: To the extent feasible for an approved outright “industrial use,” we have incorporated many pedestrian plazas with bench and table seating and textured concrete surfaces with areas of landscaping to soften the edges. The pedestrian plazas around the primary entrance created an inviting entrance for the customers. Other pedestrian areas were created for employees as shown. (c) Pedestrian Areas: Pedestrian plazas has been strategically placed at the primary building A entrance and building B entrance to bring attention to all new and existing users. It is easily seen and draws the eye to the primary entrance for all new customers. (d) Overall Design Continuity – The building will have a split face CMU wainscot from finished floor to 3’-4” and metal siding above to the building eave. The bottom of window sills will align with the top of cmu wainscot. The trash enclosures will have the same split-face cmu wall that matches the base of the building. The body shop will also have the same wainscot to match. Pape also has their signature yellow paint band that integrates with their building and the wall signage. At the building entry, there will be a 6’ minimum, 8’ maximum overhang with a special protruding “eyebrow” design element and two 24” columns to express “Entry.” A similar eyebrow will occur at the SE Corner of the Body Shop. (e) Physical Features: Both the primary building A and body shop building B are very visible from the 32nd Avenue South. Although we will have a 6’ height, black vinyl-coated chain link fence at the perimeter of the facility, majority of areas on-site will be visible. Pape Kenworth NW Design Guidelines May 29, 2020 Page 3 (f) Access Control: The site will have a 6’ high perimeter black vinyl-coated chain link fence with gates at the driveway approaches. Only building managers will have access to open the gates in the morning and close at night. Manager’s, or those assigned, will typically be in a passenger car and 25-27’ queue depth should suffice for them to park, get out, open the gate, then drive in without blocking any traffic along 32nd Ave S. (g) Utilize Site Design that Reflects Ownership: Property will be completely surrounded by a 6’ height black vinyl-coated chain link fence and will be primarily paved on-site with ¾ street improvements on 32nd Avenue South and sidewalk improvements and pavement extensions on S. 320th Street. Site will be surrounded by a landscape buffer and will be maintained; 15’ along 32nd Ave S. and 5’ along all north, west and south perimeters. The Owner of the facility has their own clientele to make sure the image of the facility meets their minimum standards. (2) Surface Parking Lots: Site and landscaping for parking lots will conform to the current chapter 19.125 of the Federal Way Revised Code. This is an industrial facility that sells and maintains Kenworth trucks and will require wide turning movements due to accommodating 63-68’ long trucks. This site has two ways in and out. Majority of incoming truck traffic will have clearly delineated and controlled areas to enter along the south driveway and check into the facility along the east side of Building A with a canopy overhang. For Pac-Lease customers, they will enter along the north driveway and check in along the north side of building A under the canopy overhang. All driveway to entry areas are visible from the right-of-way (3) Parking Structures: Not Applicable (4) Pedestrian Circulation and Public Spaces: (a) Primary entrances: Primary entrance is clearly visible from 32nd Avenue South along south side of the primary building A. Accessibility from parking stalls and pedestrian plazas to building entries will be provided. All accessible stalls will be placed adjacent to the building to eliminate the need for accessible walks from crossing the drive aisles. Building B will have accessible stall along the north side adjacent to the primary entrance. (b) Pedestrian Pathways & Areas: Accessible stalls have been places against the building to avoid pathways into the vehicular way. East and West passenger parking stalls have been connected to building A by means of a 5’colored concrete walk flush with asphalt surfaces with maximum cross slopes of 2% max and 5% maximum in the direction of travel. All slopes within the accessible stalls, aisles and pathways to the building will have 2% maximum slopes unless at ramps. (c) Pedestrian Connections: Due to on-site grades, each building will have an accessible stall with an accessible path to the primary entrance of each building A and B (d) Bike Racks – Project includes bike racks at the entrance to each building. 6 bikes at building B and 6 bikes at building A. Refer to pedestrian plazas for locations. Pape Kenworth NW Design Guidelines May 29, 2020 Page 4 (e) Outdoor Furniture: On-Site furniture, lighting, freestanding signs, benches trash receptacles and fencing has been incorporated into the design. Majority of furniture items will be located adjacent to the building or at the building entry plaza areas (5) Landscaping: 15’ wide landscape screen along 32nd Avenue South and 5’ along the north, west and south property lines will be provided at the property perimeter. At passenger parking stall areas, parking lot landscaping will be provided as shown. Refer to Landscape plan. (6) Commercial Service and Institutional Facilities: All outdoor trash enclosure areas will be screened with 6’ height cmu walls along with Type III screening, minimum 6’ wide to soften the edges per FWRC 19.12.040. The split faced cmu will match the building wainscot. The Trash enclosure on the West side of Building B, Body Shop, will have a covered trash enclosure and the bump-out will act as building modulation. The trash enclosure on the west side of building A will be uncovered and is less than 175 sf (173 sf). Since this is commercial service, location of trash enclosures are placed to provide maximum circulation for truck turning radii and minimum visibility by placing enclosures furthest from the road or on the backside of the building. Electrical transformers will be screen with type I landscape screen if located in the front yard. Location of transformers to be determined. (7) Lighting: See Site Photometric. Lights have been strategically placed to illuminate key portions of the site via building lights and 25’ to 30’ high pole lights, subject to BPA review and comment within their easement area. By directing sharp cut-off lights toward to interior of the site, this will mitigate light spillage offsite as illustrated by the foot-candle layout attached. 19.115.060 - Building Design – All Zoning Districts (1) General Criteria: (a) Natural Topography: Natural topography is being used, however has been heavily influenced by Bonneville Power ‘s (BPA) 262.5’ wide overhead easement in which absolutely no building or building overhangs may be constructed within this easement. Additionally, we have wetlands to the west and have utilized this are for storm detention facilities and retained the wetland and buffers toward the west, minimizing modifications to this buffer and attempting to meet the Owner’s minimum programmatic needs for office and shop space. Between the wetland buffers, steep slopes, detention facilities and BPA/Construction Easements, the site is encumbered by 64%. Due to the “Low Boy” Trucks entering and exiting the site, (Low boy trucks have trailers that ride approximately 6-7” above the paved surface to provide easy access for large, heavy equipment such as backhoes and larger tractors/blades), we had to match grades at 32nd Avenue South at the driveways and level out the site as much as possible to provide a flat paved area that the low boy trucks could enter and exit without scraping bottom. This dictated the building layout to occur on the north side and hugs the east side adjacent to 32nd Ave S. to maintain as much distance from the wetlands and steep slopes to the west. The layout also carves the paved parking surface around the NW Corner to mitigate steep slopes, high retaining walls and structural fill. Pape Kenworth NW Design Guidelines May 29, 2020 Page 5 Building B, body shop, is independent from the main facility due to their separate operation and the BPA overhead easement as mentioned above. It was programmatically required to have 5-6 drive- through bays and is currently within 1’ of the BPA overhead easement. (b) Building Siting: Due to the above, building A siting was limited to the northeastern portion of the site and we are not aware of any views being obstructed that were designated by the comprehensive plan or other adopted plans or policies. Building B was limited to the SE corner of the site and is 9’ lower in grade from the primary building due to natural topography. No viewpoints blocked that we are aware of designated by the comprehensive plan or other adopted plans/policies. (c) Materials and Design Features of Fences and Walls: The Trash enclosure walls will reflect the split-face cmu wainscot on the building and the retaining walls along the NW, West and East sides will be constructed out of a similar split faced “key-stone” wall that will emulate the split-faced cmu on the building or 3-4 man rockery that will reflect the natural forest-like setting to the west. (2) Building Façade Modulation: All building facades are required to have 2 of the four options listed in this section. Following are options used for each elevation for Primary Building A: BUILDING A : OFFICE, SHOWROOM AND SHOP North Elevation Shop:  Option c, contains a canopy, 25’ deep, full length elevation, see plan  Option a, facade modulation used, see site plan/floor plan for modulation sizes North Elevation Office/Showroom/Parts:  Building length of 57’ on each side, < 60 feet, no modulation required South Elevation:  Option c, Canopy 6’ deep x 162’ long on 212’ long elevation; 162/212 = 76%>50%, ok  Option d, Pedestrian Plaza, 2,350 sf% (2350/56,672 = 4% > 1%, ok) Your comments indicated one plaza per building would be acceptable; we would apply this to the south elevation  In addition, option a, Façade modulation is also used to express entry. We propose a special design feature along the front entry that meets majority of the façade modulation, but per 19.115.060 (2)a, other angular forms may be considered if intent of section is met; we believe this meets the intent. Also, we have applied a portion of the pedestrian plaza in the front, which excludes public ROW adjacency, but still provides for a festive entrance. When two or more options are provided, applicant may request planning review so the above combination may be acceptable. West Elevation Parts Warehouse:  Option b, 8’ Type II landscape screen applied to this elevation  Option a, façade modulation applied, see site plan and floor plan for modulations Pape Kenworth NW Design Guidelines May 29, 2020 Page 6 West Elevation Shop:  Option c, canopy, 15’ deep across entire elevation  Option a, façade modulation applied, see site plan and floor plan for modulations East Elevation Parts Warehouse:  Option a, façade modulation applied, see site plan and floor plan for modulations  Option c, 25’ deep canopy applied to this elevation >50% East Elevation Shop:  Option a, façade modulation applied, see site plan and floor plan for modulations  Option c, 15’ deep canopy applied to this elevation >50% BUILDING B – BODY SHOP: B - North:  Option c, contains a canopy, 15’ deep > 50%  Option a, façade modulation applied, see site plan and floor plan for modulations B - West:  Option b, landscape screen, 8’ wide at base of building with type II screen  Option a, facade modulation applied, see site plan and floor plan for modulations B - South:  Option c, contains a canopy, 15’ deep  Option d, pedestrian plaza Southeast side of bldg., 602 sf (602/14000= 4%, >1%, ok)  Option a, façade modulation applied, with 6’ overhang, see site plan and floor plan for modulations Façade modulation is also used to express entry. We propose a special design feature along the front entry that meets majority of the façade modulation, but per 19.115.060 (2)a, other angular forms may be considered if intent of section is met; we believe this meets the intent. Also, we have applied a portion of the pedestrian plaza in the front, which has public ROW adjacency, but no public access due to security fence. This plaza still provides area for employees. When two or more options are provided, applicant may request planning review so the above combination may be acceptable. B - East:  Option b, landscape screen, 8’ wide at base of building with type II screen is superceded by the 15’ type I screen. Option d, pedestrian plaza Southeast corner and Northeast corner of building. Plazas are both double size of 200 sf minimum, so one can share the east elevation with either north or south elevation  Option a, façade modulation applied, see site plan and floor plan for modulations Pape Kenworth NW Design Guidelines May 29, 2020 Page 7 (3) Building Articulation & Scale: Items incorporated under section (b) area as follow:  Elevations will have items o ii, window openings with metal trim, o vi architectural overhangs/projections/canopies/ awnings o vii material variations such as cmu brick veneer from finished floor to 3’4 a.f.f., metal siding texture and metal color banding around the building to break up mass of facades. o Viii Landscaped public plazas for sitting, eating and several have space for vendor carts (4) Methods to reduce building massing: (2) Project utilizes two primary building masses to bring the massing down in size. Building modulation, canopys, landscaping and special façade modulation measures have been applied to the exterior elevations to assist in breaking the building massing into smaller units. 19.115.070 Building and Pedestrian Orientation: All Zoning Districts: (a) Building A length aligns with 32nd Avenue South. The primary entrance is along the south side of the building since Truckers will enter off of the south driveway and head to the east side of the check-in canopy. Passenger cars and office workers will enter the site and will be able to see the entrance from the south driveway along 32nd Avenue South. Building B aligns with 32nd Ave S and primary entry is along NE Corner. As primary customers enter the south driveway, they will check into the main building, then be directed to the body shop to the south where entry is clearly visible. (b) Building A pedestrian plazas have been located at the front of the office/showroom/parts warehouse building for use by employees. Pedestrian plazas on Building B are located strategically at the entry and southeast side to allow for seasonal sun or shade. (c) Visual transparency along SE corner of building A will be provided into the showroom / office / Entry area. Other areas are not intended to have transparency. Building B will have visual access to the primary entrance and some glass in the overhead doors for natural lighting. Pape eye-brow design element will be visible from S. 320th Street to show presence of the facility. (d) Two buildings will be provided on-site however are separated by a grade difference of approximately 9’ due to existing terrain and matching grades along 32nd Avenue South. The Body Shop building at the SE Corner of the site is an independent business for fixing bodies of truck cabs and the maintenance shop to the north is used to mechanically maintain existing customers trucks. A pedestrian path has not been provided since the path would not be accessible. Per IBC 1104, this section does not mandate connection especially if it has a vehicular way not accessible by pedestrians per 1104.2, exception 2. On this particular site, we do not wish to encourage pedestrian traffic within a high vehicular use site with large trucks. 19.115.090 District Guidelines: (a) Building A: Majority of passenger vehicle parking are located along the south side of the building in front of the primary entrance to the office/showroom area. There will also be parking along the rear Pape Kenworth NW Design Guidelines May 29, 2020 Page 8 (west) and front (East). Building B will have employee parking for 6 stalls along north side of building adjacent to the primary building. (b) Primary building entrance at building A will be located along the south side and will be visible from North bound traffic along 32nd Ave S. Majority of customer traffic will enter from S. 320th Street, turn North bound onto 32nd Ave. S. Primary building entry will have an entrance canopy, awning with glass windows below along with building wall signs above the main entry to express entry, making this an easily identifiable location for new and existing customers. Building B will have primary building entrance along Northeast corner, visible from 32nd Ave S and from the primary building A and will have windows, canopy overhangs and signage to express entry. (c) Entry – Both building A and B will have transparent glass and pedestrian scale overhangs/plazas for both emphasizing entry and providing weather protection. (d) Both building A & B will have ground floor entry plazas that exceed the minimum areas and will provide seating, garbage containers and bike racks. Certain plazas will be populated with concrete tables per site plan. (e) No Ground-level mirror /reflected glass will be used on either building A or B. (f) Entire facility will be surrounded by 6’ chain link fencing that will have black vinyl coating with black powder coated posts primarily for security purposes. End of Design Guideline Review