Loading...
20-105047-UP-WATER AVAILABILITY-12-29-2020-V1Lakehaven WATER & SEWER DISTRIC I WATER CEt I VIM E OF XWEMILITI Lakehaven Water & Sewer District - Development Engineering Section 31623 - 1st Ave S * PO Box 4249 * Federal Way, WA 98063-4249 Email: DE@Lakehaven.org * Telephone: 253-945-1581 or 253-945-1580 This certificate is intended to provide the applicant, land use agencies &/or public health departments with information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole discretion, reserves the right to delay, or deny, water service based upon capacity &/or supply limitations in Lakehaven's or Other Purveyor's system facilities. Proposed Land Use: ❑ Building Permit-SFR () ❑ Building Permit-MFR () ® Building Permit -Other ❑ Subdivision () ❑ Short Subdivision () ❑ Binding Site Plan ❑ Boundary Line Adjustment ® Other (specify/describe) Coffee Stand V-B Tax Parcel Number(s): 1321039067 Site Address: 3450 SW 32V11 St, FW LWSD GIs Grid: E-09 Ex. Bldg. Area to Remain: sf WATER SYSTEM INFORMATION New Bldg. Area Proposed: 600 sf 1. ® Water service can be provided by service connection to an existing 6" diameter water main that is approximately 5 feet from the site. 2. ❑ Water service for the site will require an improvement to LWSD's water distribution system of: ❑ a. feet of " diameter water main to reach the site; and/or ❑ b. The construction of a water distribution system on the site; and/or ❑ c. A major portion of LWSD's comprehensive water system plan would need to be implemented and/or constructed; and/or ❑ d. Other (describe): 3. ® a. The existing water system is in conformance with LWSD's Comprehensive Water System Plan. ❑ b. The existing water system is not in conformance with LWSD's Comprehensive Water System Plan and an Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits. 4. ® a. The subject property is within the corporate limits of Lakehaven Water & Sewer District, or has been granted Boundary Review Board approval for extension of water service outside of LWSD's water service area. ❑ b. Annexation or Boundary Review Board approval will be necessary to provide service. 5. Water service is subject to: ® a. Payment of connection charges (to be determined by LWSD); ® b. Proof or reservation of easement(s) as required by LWSD; ® c. Other: LWSD Service Connection Application required. Comments/special conditions: The nearest fire hydrant is approximately 35+ - feet from the Property (as marked on map on the back of this page). Fire Flow at no less than 20 psi available within the water distribution system is a minimum 1000 GPM for two (2) hours or more. This flow figure depicts the theoretical performance of the water distribution system under high demand conditions. Fire flow rates greater than this may be accommodated through water distribution system improvements, contact LWSD for additional information. 440 Pressure Zone Est. Meter Elevations)-GIS: High 206+/-, Low 200+/- Est. Pressure Range at Meter(s) (psi): 99-104 I hereby certify that the above water system information is true. This certification shall be valid for one (1) year from the date of signature. Name: BILL NELSON Title: ENGINEERING TECHNICIAN III Signature: �!��� -i�oii (signed electronically) Date: 10/30/20 1321039067 wtr pg 1 (Form Update 3/13/20) Page 1 of 1 Lakehaven 1321039075 320 35th AVE SW $„ W W --A 1321039073 3560 SW 320TH ST 1321039084 .q� 3440 SW 320TH ST 8731902740 Five „ C"\ $„ pi r /r G 8731902740 Six NOTE: Lakehaven Utility District neither warrants noril guarantees the accuracy of any facility information provided.11 0 50 100 Facility locations and conditions are subject to field verification. 10/29/20 11 Feet Lakehaven SEWER CERTIFICATE OF AVAILABILITY Lakehaven Water & Sewer District - Development Engineering Section 31623 - 1st Ave S * PO Box 4249 * Federal Way, WA 98063-4249 Telephone: 253-945-1581 or 253-945-1580 * Email: DE@Lakehaven.org This certificate is intended to provide the applicant, land use agencies &/or public health departments with information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole discretion, reserves the right to delay, or deny, sewer service based upon capacity &/or supply limitations in Lakehaven's or Other Purveyor's system facilities. Proposed Land Use: ❑ Building Permit-SFR () ❑ Building Permit-MFR () ® Building Permit -Other ❑ Subdivision () ❑ Short Subdivision () ❑ Binding Site Plan ❑ Boundary Line Adjustment ® Other (specify/describe) Coffee Stand V-B Tax Parcel Number(s): 1321039067 Site Address: 3450 SW 320t-11 St, FW LWSD GIS Grid: E-09 Ex. Bldg. Area to Remain: sf SEWER SYSTEM INFORMATION New Bldg. Area Proposed: 600 sf 1. ® Sewer service can be provided by service connection to an existing 5" diameter sewer main that is approximately 30 feet from the site and the sewer system has the capacity to serve the proposed land use. 2. ❑ Sewer service for the site will require an improvement to LWSD's sanitary sewer system of: ❑ a, feet of " diameter sewer main or trunk to reach the site; and/or ❑ b. The construction of a sanitary sewer collection system on the site; and/or ❑ c. A major portion of LWSD's comprehensive wastewater system plan would need to be implemented and/or constructed; and/or ❑ d. Other (describe): 3. ® a. The existing sewer system is in conformance with LWSD's Comprehensive Wastewater System Plan. ❑ b. The existing sewer system is not in conformance with LWSD's Comprehensive Wastewater System Plan and an Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits. 4. ® a. The proposed site land use is within the corporate limits of Lakehaven Water & Sewer District, or has been granted Boundary Review Board approval for extension of sewer service outside of LWSD's sewer service area. ❑ b. Annexation or Boundary Review Board approval will be necessary to provide service. S. Sewer service is subject to: ® a. Payment of connection charges (to be determined by LWSD); ® b. Proof or reservation of easement(s) as required by LWSD; ® c. Other: LSWD Service Connection Application required. Comments/special conditions: I hereby certify that the above sewer system information is true. This certification shall be valid for one (1) year from the date of signature. Name: BILL NELSON Title: ENGINEERING TECHNICIAN III Signature: `Al//-'f14I. i (signed electronically) Date: 10/30/20 1321039067 swr pg1 (Form Update 4/2/19) Page 1 of 2 LakehaVen V.,AIf R & Y. vi R OIN fill' I / IOTE: Lakehaven Utility District neither warrants not uarantees the accuracy of any facility information provided acility locations and conditions are subject to field verification. 1321039073 3560 SW 320TH ST 1321039084 3440 SW 320TH ST 8731902740 Six 0 50 100 Feet 873190078 32161 33R AVE SW 8731900790 32165 33RD AVE SW 10/29/20