Loading...
20-105049-UP-ARCHITECTURAL PLANS-12.29.2020-V1Parking Analysis for Cross -use Parking Agreement Parking Analysis for Twin Lakes Plaza: 3SE = Jump Start Espresso/Site (B) = Business TLP = Twin Lakes Plaza/Site (M) = Mercantile E = Existing BLDG SIZE USE PARKING PARKING/TOTAL (B) = BUSINESS Accessible and (E) = EXISTING M = MERCANTILE/RETAIL Standard Stalls [Note 5] A 30' X 60' = 1800 S.F. 1800 S.F. OFFICE B M 1/300 = 6 E B 100' X 40' = 4,000 S.F. 1,600 S.F. HAIR (B) 1/300 = 6 (E) 2,400 S.F. RETAIL M 1/300 = 8 E C 80, X 40' = 3,200 S.F. 1,600 S.F. OFFICE (B) 1/300 = 11 (E) 1600 S.F. RETAIL M 1 D 40' X 60' = 2,400 S.F. 2,400 S.F. OFFICE B 1/300 = 8 E E 40' X 40' = 1,600 S.F. 800 S.F. DRY CLEAN (B) 1/300 = 5 (E) 800 S.F. SPA/NAILS B TOTAL -� -> 1/300 = 44 (E) 59 (E) Proposed for Jump Start Espresso: 37' X 22' O.A. Jump Start Roof Area Drive Thru Espresso Interior Space = 561 S.F. 691/80 = 9 Stalls Required [Note 2] Outdoor Seating = 130 S.F. Total Area = 691 S.F. See Note 3 TOTAL REQUIRED = 44 @ Twin Lakes Plaza + 9 @ JSE = 53 Spaces [Note 1] SHARED i FOUR (4) STALLS WILL BE BUILT ON THE JUMP START ESPRESSO SITE I PLUS 1 PARKING PROPOSED (5) STALLS TO BE RE -STRIPED @ THE TWIN LAKES PLAZA SITE FOR A TOTAL OF (9) € SPACES TO BE ATTRIBUTED TO THE JUMP START ESPRESSO PROJECT NOTE 4 Note 1: I AN ADDl_ 13 STALLS CAN BE ADDED ON THE TWIN LAKES PLAZA SITE BY RE -STRIPING THE EXISTING PARKING @ THE AREA NORTH OF THE JUMP START ESPRESSO SITE FOR A COMBINED TOTAL FOR BOTH SITES TO 72 PARKING STALLS Note 2: ! JSE REQUIRED PARKING = 1 STALL/80 S.F. (SEE PRE -APPLICATION CONF. LETTER) Note 3: 3 NO INTERIOR SEATING WILL BE PROVIDED. Note 4: ' FIVE SPACES AT TLP WILL DESIGNATED TO THE JSE DEVELOPMENT THRU SIGNAGE i AND/OR PAINTED STALLS Note 5: { EXISTING = STALLS CURRENTLY `STRIPED' @ THE TWIN LAKES PLAZA SITE. NOTE 6: ONE (1) ACCESSIBLE VAN STALL PROVIDED / ONE (1) PER 25 REQUIRED POSES w NETTtAG 'y� (D . .-15'_REQ'D LANDSCAPING u (E) LEGEND LEGEND (PLAN VIEW) SYMBOL MATERIAL / ITEM SYMBOL MATERIAL / ITEM EXTERIOR WALL STUD WALL w/ HARDIE SIDING y , (@ INTERIOR) CMU WALL GYPSUM WALLBOARD (@ TRASH/RECYCLE) (GWB) DETAIL NO. (E) EXISTING DETAIL SHEET N0. SECTION I.D. INTERIOR SECTION SHEET NO. SHEET No. ELEVATION FYI "'�� I1. =, BAIT INSULATION RIGID INSULATION DDUPLEX SS STAINLESS STEEL 4-PLEX LIGHT SWITCH OUTLET 3 WAY LIGHT ^'I WALL SCONCE 3 SWITCH SURF = SURFACE MOUNTED ® THERMOSTAT LIGHT FIXTURE R = RECESED FIXTURE HwT HOT WATER TANK OD SPECIAL POWER EQUIPMENT DOOR (SEE EQUIPMENT SCHEDULE) (SEE SCHEDULE) x ❑ WINDOW 0 REVISION (SEE SCHEDULE) 100 CFM EXHAUST FAN w/ LIGHT - EXH. TO ATMOS. EXIT SIGN w/ LIGHTS & BATTERY BACK-UP +� SOFFIT LIGHT WALL MOUNTED LIGHT (EXTERIOR) (EXTERIOR) PARKING LOT LIGHT FIXTURE BOLLARD: 6" 0 STEEL PIPE r7on SITE PLAN (3) PLACES ® FILLED w/ CONC. (SITE PLAN) DET. 9 SHT. A5.0 - 4 PLACES O PARKING LOT BOLLARD' LIGHT (E) = EXISTING SITE PLAN - (3) PLACES 9 -T PAR QNG STALLS @ EXIS 'G PARKING L�T PE k CRO S-USE PARKIN G-AGREEMENT- 5 N 52029' 56" E 144.88'}. Q U) =RETAINING ALL 0 3431 SW 320th STREET Twin Lakes Plaza I -10' BLDG SETBACK ao ETENTION POND w/ RET PARCEL 132103 67_ off, w WALL & SWPED SIDES M � .\NO-VqAy AISLE o v r TRASH ° ENCLOSURE ---- - ACCESSIBLE PARKING Q\ STALL I MEN _ C - a �Q -0" WIDE STALL.:.. w/ 8' MAN'G AREA BOA D STD P RKING (9' 187 a , ]UMP_STA.RT ESPRESSO 4 _ _ "- -- BIORETENTIOH 1 �, .. - -- -- �• DRIVE UP SEA - R 531.9' p = 20603' 19" L = 185.9 ' 5' REQ'D LANDSCAPING y" - EXIST'G S/W -� S/W TO BE REPAIRED SOUTHWEST 320TH STREET A Site Plan il' = 1-01-0'1 d 5' Its' 2a� 4c?l #PEDES-F I WNNECTOR General Notes: 1. ALL WORK SHALL CONFORM TO REQUIREMENTS OF THE FOLLOWING AS THEY MAY APPLY: International Building Code (IBC), 2015 edition, including Appendices E and J ° Washington State Amendments, WAC 51-50 and RCW 19.27 & 70.92 ° Accessibility Code ICC/ANSI A117.1-2009 International Mechanical Code (IMC), 2015 edition - Washington State Amendments, WAC 51-52 and RCW 19.27 ° International Fire Code (IFC), 2015 edition, including Appendices B, C, E, F, and I - Washington State Amendments, WAC 51-54A and RCW 19.27 ° International Existing Building Code (IEBC, 2015 edition ° International Fuel & Gas Code (IFGC), 2015 edition ° International Property Maintenance Code (IPMC), 2015 edition ° International Energy Conservation Code (IECC), 2015 edition - Washington State Amendments, WAC 51-IIR & 51-11C and RCW 19.27 Washington State Energy Code (WSEC), 2015 edition ° National Electrical Code (NEC), 2017 edition Washington State Amendments, WAC 296-43, 296-45 & 296-46B and RCW 19.28 ° Uniform Plumbing Code (UPC), 2015 edition, excluding Chapters 12 and 15 - Washington State Amendments, WAC 51-56 and RCW 19.27 ° & ALL OTHER APPLICABLE CODES AS ADOPTED OR EXCLUDED BY THE CITY OF FEDERAL WAY. 2. THE SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED TO BE CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING THEM, OR THEIR EXACT MEANING, THE ARCHITECT SHALL BE CONTACTED FOR CLARIFICATION. 3. OWNER OR AGENT SHALL SUBMIT FOR BUILDING PERMIT. 4. ALL FRAMING MEMBERS SHALL BE SO ARRANGED AND SPACED AS TO PERMIT INSTALLATION OF PIPE CONDUITS AND DUCTWORK WITH A MINIMUM OF CUTTING. 5. CONTRACTOR SHALL PROVIDE AND INSTALL ALL STIFFENERS, BRACES, BACK-UP PLATES, AND SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF ALL WALL MOUNTED OR SUSPENDED STAIR RAILINGS, CASEWORK, TOILET ROOM ACCESSORIES, MECHANICAL, ELECTRICAL, PLUMPING, OR MISCELLANEOUS EQUIPMENT. 6. INSTALL METAL CORNER BEADS AT ALL EXPOSED WALLBOARD EDGES. INSTALL CASING BEADS WHEREVER GWB, PLASTER, ETC. ABUTS A DISSIMILAR FINISH MATERIAL & PROVIDE SEALANT AS REQUIRED. 7. ALL COLORS, FINISHES, TEXTURES, ETC. AS DIRECTED BY OWNER AND/OR ARCHITECT. 8. ALL FIRE RATED ASSEMBLIES SHALL BE ICBO OR UL APPROVED AND PROVIDED AS INDICATED ON THE APPROVED DRAWINGS. ANY PENETRATIONS AT THE FIRE RESISTIVE ASSEMBLIES SHALL BE SEALED WITH UL APPROVED FIRE STOPPING. SUBMIT METHOD OF FIRE STOPPING TO BUILDING INSPECTOR FOR APPROVAL. 9. FURNISH AND INSTALL EMERGENCY LIGHTING. IN NO CASE SHALL THE LIGHTING LEVEL BE LESS THAN ONE -FOOT CANDLE AT FLOOR LEVEL IN ALL HALLWAYS. VERIFY MODIFICATIONS TO EXISTING SPACES(S) IF NECESSARY. 10, ALL EXIT SIGNS SHALL HAVE 6" HIGH LETTERS IN ACCORDANCE WITH LOCAL CODES OR SHALL CONFORM TO IBC REQUIREMENTS. LUMINANCE ON SIGN SHALL BE 50 LUX. ILLUMINATED EXIT SIGNSTO HAVE RESERVE POWER. 11. ALL DOOR SIZES SHOWN ON THE DOOR SCHEDULE ARE OPENINGS SIZES. ALL DOORS AND FRAMES SHALL BE REINFORCED WHERE REQUIRED FOR CLOSERS, STOPS, HARDWARE, ETC. 12. DOORS IN RATED WALLS SHALL CONSIST OF SELF-CLOSING/LATCHING ASSEMBLIES WITH SMOKE & DRAFT SEALS AT HEAD & JAMB. DOOR ASSEMBLY RATINGS SHALL BE COMPATABLE WITH WALL RATING [PER IBC]. 13. EXIT REQUIREMENTS: a. ALL LEGAL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT AND SHALL HAVE SIGNS POSTED READING "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS". b. CONTRACTOR SHALL PROVIDE TEMPORARY EXITS SIGNS TO ASSURE A MEANS OF EGRESS DURING CONSTRUCTION, AS MAY BE NECESSARY. c. DOORS EQUIPPED WITH PANIC HARDWARE SHALL BE OPERABLE WITH A MAXIMUM FORCE OF 15 LBS. APPLIED IN THE DIRECTION OF EGRESS TO THE BAR. d. CLOSING SPEED: DOOR CLOSERS SHALL ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION OF TWELVE (12) DEGREES SHALL BE FIVE (5) SECONDS MINIMUM.[ACC/ANSI 117.1 2009 404.2.7.1] e. OPENING FORCE: FIRE DOORS SHALL THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE FORCE FOR PUSHING OR PULLING OPEN DOORS OTHER THAT FIRE DOORS SHALL BE FIVE (5.0) POUNDS FOR INTERIOR HINGED DOORS [ICC/ANSI 117/1- 2009] - 14. BARRIER FREE ACCESS REQUIREMENTS: SHALL COMPLY WITH BARRIER FREE REQUIREMENTS AND SHALL BE IN COMPLIANCE WITH 2O15 IBC CHAPTER 11 AND ICC/ANSI A117.1-2009. 15. MECHANICAL/Heating SYSTEM SHALL BE "BIDDER/DESIGN". a. SCOPE OF WORK: Electric wall heater with thermostat(s) b. VERIFY ALL REQUIREMENTS WITH AGENT &OWNER. c. CONTRACTOR IS RESPONSIBLE FOR OBTAINING REQUIRED PERMITS d. SYSTEM SHALL COMPLY WITH THE WASHINGTON STATE ENERGY CODE FOR FRESH AIR & VENTILATION REQUIREMENTS PER IBC CHAPTER 12 & THE WSVIAQC - AS APPLICABLE. 16. PLUMBING SHALL BE "BIDDER/DESIGN". . a. REVIEW EXISTING UNDERGROUND SYSTEM TO ASSURE A COMPLETE OPERATIONAL SYSTEM b. VERIFY ALL REQUIREMENTS c. SUBMIT DESIGN TO INCLUDE DRAWINGS ALL CALCULATIONS AS REQUIRED FOR APPROVAL BY THE CITY. d. CONTRACTOR IS RESPONSIBLE FOR OBTAINING REQUIRED PERMITS. 17. ELECTRICAL SYSTEM SHALL BE "BIDDER/DESIGN". a. SCOPE OF WORK: NEW LIGHTING SYSTEM NEW LIGHT FIXTURES b. VERIFY ALL REQUIREMENTS WITH AGENT AND/OR OWNER. c. COORDINATE TENANT PROVIDED AND EXISTING EQUIPMENT AS REQUIRED. d. CONTRACTOR IS RESPONSIBLE FOR OBTAINING REQUIRED PERMITS e. INSTALLATION OF ELECTRICAL EQUIPMENT, LIGHT FIXTURES, EXIT SIGNS, AS INDICATED ON THE PLANS, IS CONCEPTUAL. FINAL LOCATION(S) SHALL BE BASED ON THE ACCEPTED ELECTRICAL SUBCONTRACTORS DESIGN. 18. FIRE ALARM SYSTEM SHALL BE "BIDDER/DESIGN". a. VERIFY ALL REQUIREMENTS WITH agent or OWNER AND FIRE MARSHALL. b. SUBMIT DRAWINGS AND CALCULATIONS FOR APPROVAL AS REQUIRED BY THE CITY. c. CONTRACTOR IS RESPONSIBLE FOR OBTAINING REQUIRED PERMITS 19. COORDINATION OF SECURITY SYSTEM. a. PROVIDE SECURITY SYSTEM COORDINATED WITH AS DIRECTED BY OWNER. b. SUBMIT DRAWINGS AND CALCULATIONS FOR APPROVAL AS REQUIRED BY THE CITY. c. CONTRACTOR IS RESPONSIBLE FOR OBTAINING REQUIRED PERMITS 20. PROVIDE FIRE EXTINGUISHERS AS REQUIRED, VERIFY PLACEMENT AND REQUIREMENTS WITH THE FIRE MARSHAL. 21. THESE DRAWINGS AND SPECIFICATIONS DO NOT INCLUDE THE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. THE SAFETY, CARE OF ADJACENT PROPERTY DURING CONSTRUCTION, COMPLIANCE WITH STATE AND FEDERAL REGULATIONS REGARDING SAFETY SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 22. FIELD VERIFY ALL EXISTING CONDITIONS & DIMENSIONS. REPORT DISCREPANCIES TO ARCHITECT AND/OR GENERAL CONTRACTOR. Civil: AP Consulting Engineers, PLLC Adam Paul, P.E. PO Box 162 Auburn, WA 98071 Landscape Architect: Bradley Design Group, Inc. Kathleen Reader, Principal Landscape Architecture Consultants: Structural: Visser Engineering Andy Derrick, P.E. 33001 Avenue South (320) Federal Way, Washington Soils: GEOTECH Consultants, Inc. Marc R. McGinnis, PE 13256 BE 20t" Street, Suite 16 Bellevue. Washington 98005 Surveyor: Centre Pointe Consultants, Inc. P.S. Norm Larson, PLS ' 14209 29th Street East (105) Sumner, Washington 98390 I Traffic: Heath & Associates Inc. I Greg Heath, PE, PTOW 2214 Tacoma Raid Puyallup, Washington 98371 I Zoning & Building Code Notes: New Drive Thru Coffee @ 3450 Southwest 320th Street Federal Way, Washington Scope of Work: o NEW ONE-STORY 561 S.F. BUILDING (Conditioned Space) o OUTDOOR/COVERED SEATING AREA (130 S.F.) for JUMP START ESPRESSO & COFFEE DRIVE-THRU with: o OUTDOOR COVERED SERVING AREA (108 S.F.) @ DRIVE-THRU Owner: Twin Lakes Plaza LLC o 33919 Ninth Avenue South, Suite 201 Federal Way,Washington 98003 Building: Construction T VB INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION, INCLUDING APPENDICES Code References: E & J WASHINGTON STATE AMENDMENTS, WAC 51-50 AND RCW 19.27 & 70.92 ACCESSIBILITY CODE ICC/ANSI A117.1-2009, 2015 IMC, IPC, UPC, OFGC, IFC & WASHINGTON STATE ENERGY CODE, ALL STATE AMENDMENTS & APPLICABLE CODES AS ADOPTED OR EXCLUDED BY THE CITY OF FEDERAL WAY Occupancy/Use: Existing: Vacant Site Proposed: Drive Up Coffee Service - (B) Occupancy Zoning: Zone Neighborhood Business BN Building Height 35' Max. . Proposed Height = 18' ± @ `Tallest' Point (Ridge) Side/West = 15' 15' Required Landscape Buffer (Type III) Setbacks Rear/North = 10' 5' Required Landscaping (Type III) Front/South 0 5 Required Landscaping (Type III) Landscaping 5' @ North, South & East Prop. Lines Note: P 9 15' @ West Property Line R7.2 Zone to the West Requires a 15' Type III Buffer Required Provided ONE STALL REQ'D PER 80 S.F. - (3) Standard (9' X 18') Stalls On -Site & (1) Accessible/Van Stall proposed On -Site Parking: or - (4) Stalls to be located on the adjacent Twin (561 S.F. + 130 S.F. = 9 STALLS Lakes Plaza site via Shared Parking Agreement to 80 S.F. be executed with Twin Lakes Plaza Jump Espresso Parkinq per Pre -Application Conference Summary dated 06.10.2019 Areas: Area Occupancy Occupant Load Factor Occ. Load Jump Start Espresso 561 GSF B 1 per 80 SF 4 1) Conditioned Area = 600 S.F. Notes: 2 Outdoor Covered Seating Area @ North Side of Building = 130 S.F. Parcel Number: Legal Description Area BEG ON N LN OF NW 1/4 OF NW 1/4 868.80 FT E FR NW COR THOF TH S 35-48-36 W 605.94 FT TO BEG OF CURVE TO RGT RAD 530.96 FT TH SWLY 132103-9067 ALG SD CURVE THROUGH C/A OF 07 DEG 46 MIN 10 SEC DIST 72 FT TO 19,035 S.F. POB TH CONTG SWLY ALG SD CURVE THROUGH C/A OF 20 DEG 04 MIN 32 SEC DIST 186.04 FT TH N 26-20-42 W 115 FT TH N 53-37-02 E 145 FT TH S 46-25-14 E 115 FT TO POB Plumbing: Required Provided 1 Service Sink Floor Mop Sink Jump Start Espresso 1 Hand Wash 1 Hand Wash Sink 1 3-Compartment Sink 1 3-Compartment Sink 1 Lavatory Sink 1 Lavatory Sink 10.08.2020 Vicinity Map Architectural A1.0 Zoning & Building Notes Vicinity Map / Site Plan Drawing Symbols Legend ............... _.......... _........... Cross-UseParking Analysis ........ ................................... .._.............. A2.0 ! Floor Plan / Roof Plan Building Section A -A / Detail's . u.. ........ _......................................................................................................................... Roof Ventilation Calc's ......................_............................ ............................. _....... A3.0 _...... Exterior Elevations . _............._....................,........................................................................................................................................................................... Wall Sections / Toilet Plan ............ ..... A4.0 Equipment Plan & Schedule Interior Elevations .............................................. Building Section B-B ;..................... .......................... .... ..... .................................. ............. ........................... .......... _............. _. . ............................ A5.0 Details Civil C1 Site Plan ...................................... _.......................... ...................... -..................... _._............................ ....-............. ........................ ........................ ................ ..-................. ............... C2 TESC Plan .................. .................... ._.............................. .............................._................ ........................ ...................... _.............. ..._................................ _........... __. . . . ... ...._.................. ..._............................................ ................_.................................................. ........................................................... .................. .... C4 Sections & Details ........................................................................................ _......... _............. ............. ................ .................. ................. ... ............................................................... C5 Sections & Details Related Information to Compliment Plans: - Project Manual & Outline Specifications - Structural Calculations _ Email meh.architect hotmail Structural S1.1 1 General Structural Notes S1.2 Statement of Special Inspections S2.1 1 Foundation Plan Roof Framing Plan ............................. ................................................................................................................... S6.0 Schedules S6.1 I Details - Soils Report - Technical Information Report for pdf copies of the above information__ Al Attic Ventilation Required/Provided: 1) ATTIC AREA OVER CONDITIONED SPACE 2) ATTIC AREA OVER NON -CONDITIONED SPACE (Outdoor Seating & Walk up Service @ North Side) 3 FLAT ROOF /CANOPY @ BARISTA OUTDOOR Outdoor Covered Area for Baristas by Drive Thru Lane Areas to be Vented: 1) 561 S.F. above Conditioned Floor Area 2) 114 S.F. of Eave Area + 135 S.F. @ Covered Seating/Walk-Up Service 108 S.F. @ R22flC;knopy @ Outdoor Service Area @ Drive U Ventilation Calcs: Method Product for Venting Area of Ventilation Required & Provided Conditioned Space: 561 S.F. _ 150 = 4 S.F. X 144 S.I. = 576 S.I. RE 'D VENT AREA Ridge Vent (18 S.I. NFA/L.F.) Air Vent Inc. SHINGLEVENT II Ridge Vent = 50 L.F. X 18 S.I./L.F. = 900 S.I. NFA (47%) Eave/Soffit Vent (9 NFA S.I./L.F.) Air Vent Inc.- SOFFIT VENT Eave Vent = 114 L.F. X 9 S.I./L.F. = 1,026 S.I. NFA (53%) Non -Conditioned Space: Exterior Walk -Up & Seating @ North Side 150 S.F. _ 150 = 1.0 S.F. X 144 = 144 S.I. RE 'D VENT AREA Eave/Soffit Vent (9 NFA S.I./L.F.) Air Vent Inc. - SOFFIT VENT Eave Vent 12 L.F X 9 S.I./L.F. = 108 S.I. NFA 47% Roof Louver Vent 60 S.I NFA GAF ROOF LOUVER-SSB96OG Each Louver = 60 S.I. NFA X 2 Louvers = 120 S.I. NFA 53% Non -Conditioned Space: Exterior Barista Service Area @ South Side 1 108 S.F. _ 150 = 0.72 S.F. NFA Required Note: See Project Manual for Installation of Air Vent Products Door Schedule - 1 T-0" X T-0" X 13/4" - INSUL. HOLLOW METAL DOOR w/ SAFETY GLASS. SEE INTERIOR ELEV'S 2 Y-0" X T-0" OVERHEAD DOOR -.INSULATED 3 Y-0" X T-0" X 13/4" - SOLID CORE WOOD, PAINT. PROVIDE CLOSER & PASSAGE LOCK 4 T-0" X T-0" X 13/4" - SOLID CORE WOOD, PAINT. VERIFY LOCKING REQTS 5 3'-0",X T-0" X 13/4" • INSUL. HOLLOW METAL DOOR w/ SAFETY GLASS - VERIFY LOCKING REQTS 6 Y-0" X T-0" X 13/4" - INSUL. HOLLOW METAL DOOR w/ SAFETY GLASS. SEE ELEVATIONS 6 3'-0" X T-0" X 13/4" - INSUL. HOLLOW METAL DOOR w/ SAFETY GLASS. SEE ELEVATIONS Door Notes: a. PROVIDE HARDWARE FOR A COMPLETE, OPERABLE INSTALLATION INC: BUT NOT LIMITED TO: LEVERS, LOCKS, DRIP CAPS, WEATHER-STRIPPING, THRESHOLDS, CLOSERS, PEEP HOLE(S), ASTRAGALS KICK PLATES FLOOR MTD. DOORSTOPS HINGES & THE LIKE. b. VERIFY SECURITY/LOCKING REQUIREMENTS WITH OWNER. C. FURNISH ITEMS NOT MENTIONED BUT NECESSARY TO COMPLETE THE WORK. d. ALL WOOD SOLID CORE DOORS TO BE AWI PREMIUM GRADE. e. ALL HARDWARE PLACEMENT TO COMPLY WITH ICC A117.1-2009 & 2015 IBC Window Schedule Mark Size TYPE Misc. Notes A 4'-6" X T-6" FIXED 1) MILGARD SUN COAT LOW E, U=0.30 OR. APPROVED EQUAL 2) VERIFY REQUIRED SECURITYREQTS @ OPERABLE WINDOWS 3) GLASS TYPE TBD 4) WINDOW HEAD HEIGHT EQUAL TO DOOR HEAD HEIGHT - - - B T-0" X T-6" FIXED C 6'-0" X T-6" FIXED w/ Center Mullion D 6'-0" X 3'-6" FIXED w/ Center Mullion E 4'-6" X 4'-0" SLIDING Serving Windows F 4'-6" X 4'-0" SLIDING G 4'-0" X 4'-6" SLIDING H 3'-6" X 3'6" FIXED T-6" X 3'6" FIXED J 5'-0" X 2'-0" FIXED A3-o Building Secti-one- 0 _o tt- -t SOFFIT MTD. LIGHTS ilk(4) @ SOUTH/OUTDOOR SERVING (1) @ EACH CANOPY ----911(SURF MTD. LIGHT/UNDER CANOPY) WALL MOUNT LIGHTS (2) @ NORTH ELEVATION (1) @ SOUTH ELEVATION L�J (2) @ WEST ELEVATION (2) @ EAST ELEVATION [See Floor Plan Sht. A2.0 & Exterior Elevations Sht. A3.0] 9sAi;st49 c uTY;-A $t;Low -M1 12IS, e _III-PI�C* - Cta a J Lu li II II I� w Ij RIDGE VENT 35 L.F.I I I J---- ,-----� -- t------t--__�— _--�I I -I- ---- --�.� ,---- --}------r-- --� -I---- �-- I �I CANOPY u I T ( z -� w -- -- - -- ------ ---------- I I I I Gutter, Typ. WALL t5eI ow,-t-fP• DOWNSPOUT_+-Typ., t-r- L - r:t•rYP o, CANOPY - - — per; o Roof Plan - 1/4" - 1'-O" Y!r KI,F 2-to 41t- Ir Al ILI . 1 I I RESTROOM; f,E H n A3.6 i 5�- STORAGE —5UTDOOR SEATING (� (' - — - r C - I I t - I - i L— �--+ [HI I (4\ f I Ki �K �iJl SERVI G-2LL I'I- 2 0 1 OFFICE i '_ �� � I I`. I; , n VX SERVINGt- LI�%I OUTDOOR �ARISTA SERVICE. -- - - -- -- A 4 4 _FosT A2.6 A 4, 0 I�-U vIcS -� Floor Plan 1/4" SSE_ f5Q6W°1�'N? ('I.t i4 S A�,'.d Notes: - - - - - - - See Sht. A3.0 FOR RESTROOM Hardware Etc. (ADA COMPLIANCE, ETC.) - See Sht. A3.0 & SHT A4.0 FOR INTERIOR ELEVATIONS - See Sht. A4.0 FOR EQUIPMENT PLAN/SCHEDULE � z -60 �' C�Nt1st'eu'Y, T`fP. cv.�lbP�f o� 0 q W e® 00 Ito o = A�rr cn w s� tQ U. M e® �CO kks c C 0 %Q o Ito i M9111 . W C a C C G �. oc 2020.01- _ I RestroorYi Legend Mark Abbrev Item/Hardware Oi LAV LAVATORY MAX HGT = 34" Q2 PTD PAPER TOWEL DISP. OPERABLE PART @ 48" MAX. AFF ® WC WATER CLOSET SEAT @ 18" AFF 4 SCD SEAT COVER DISP. 50 VGB 18" VERTICAL GRAB BAR SEE PLAN FOR DIM'S 6 GB HORIZ. GRAB BAR 36" AFF - SEE PLAN 7 TPD TOILET PAPER DISP. s - MIRROR VERIFY SIZE LGT LIGHT FIXTURE - WALL/SURF MTD. 10 TSI TRAP/SUPPLY INSUL. ll - COVE BASE INTEGRAL w/ FLOOR'G EXTENDED 6" UP WALL MINIMUM QQ EXH 100 CFM EXHAUST FAN VENT TO ATMOSPHERE 1s WS P-LAM, FRP or C.T. TO A MIN. OF 60" AFF 14 FND FEM. NAPKIN RECEPT. QQ MS MOP SINK VERIFY MFR & SIZE 16 HWT ON -DEMAND HWT - WALL MTD. 17 C/A 56" X 60" CLEAR AREA 1s K/S 30" X 48" KNEE SPACE 19 - NOT USED 00 - I NOT USED NOTE: ALL PRODUCTS, HARDWARE, FINISHES, ETC. ARE CONCEPTUAL: INTENDED TO COMPLY w/ APPROP CODE REQTS. PROVIDE COPIES OF PRODUCT INFO FOR APPROVAL PRIOR TO INSTALLATION Code Reference: SEE GENERAL NOTE 1, Sht. CS1.0 BY OTHERS -- (SEPARATE PERMIT) ZOUNTER South Elevation 1/4" = 1r-O" East Elevation West Elevation v - I� L < li Toilet - 4 Toilet - 3 U4" = 1'-0" - _Toilet - 2 - Toilet - 1 Toilet Floor Plan 1/4" = 1'-0" 1/4" = 1'-0" 1/4" Interior Wall Section - Typ. Typ. Roof Construction I2 - ARCHITECTURAL SHINGLES to - ROOF UNDERLAYMENT (Tyvek Protec 200) - 1/2" PLYWD. SHEATHING - ROOF TRUSSES @ 24" O.C. - R-49 BATT INSULATION - 5/8" GWB CEILING w/ PVA PRIMER & PAINT r ? 3 + y f { , Gutter - 5/4 X fascia Hardie Soffit t Typ. Exterior Wall - EXTERIOR SIDING - See Spec's - MOISTURE BARRIER - 1/2" PLYWD. SHEATHING - 2 X 6 WOOD STUDS @ 16" O.C. - I - R-21 BATT INSULATION - 5/s" GWB - PVA PRIMER & PAINT - WAINSCOT Per SCHEDULE erior Wall 4 WOOD STUDS @ 16" ' GWB EACH SIDE PRIMER & PAINT JNSCOT per SCHEDULE =0 -o Typ. Floor Construction - 4" CONC. SLAB w/ ! 6X6XW1.4WWM - FINISH: GRIND & SEAL CONC. - 6 MIL VAPOR BARRIER - 4" WASHED ROCK FINISH SCHEDULE - COMPACTED SUB -GRADE TREATED 2 X 4 SILL PLATE ,-- Pressure treated 2 X 6 sill PI w/ 3(P. ANCHORS R 10 RIGID INSULATION ` @ SLAB PERIMETER - CORRUGATED 4" 0 PERF PIPE - SOLID 4" 0 PVC DRAINPIPE (For Roof Drainage) — -�• " r i��...�'.� `=-fir � � % — 6T o c4 i _ Exterior Wall Section -- -Typo CO00 o � 0 _ C r! �0 in LL Ea 0 t/� o (D00 L � W M •� low y � to O Cn V M F � 1 P� Cn H H d O p. v Z � H e � d O H a� A3m0 Building Section___B-B_ 1/4" = 1'-O" -¢OFL-• up DDar - Serving 1- ==T-----_-, =--- - - -- --- _ -_-_-_-r�rfl 3 - Looking South w JSE Equipment Schedule Miscellaneous Item Manufacturer Dimensions # Notes (WxDxH) A REFR AVANTCO 54" x 32 1/4" (1) V115 - AMPS SOLID DOOR A-49R-HC 54 x 821/2" 4.56 - HZ 60 KATOM B (3) COMP CS-3-15-15-14- 75" X 20 13/16" (1) SINK DB15 75" X 433/4" VERIFY C HANDSINK REGENCY DROP 10" x 14" (1) IN HANDSINK x 10" POWER & INSTALL. D ICE MAKER SCOTTSMAN 24" X 28.4" (1) UF424-49A1 X 39" REQTS E REFR 48" X 32" (1) U-C BEVERAGE AIR x 34% F BLENDERS BLENDTEC (3) P80OC2901-AlAlD - INT. SS 132" (2) w/ 5" BACK __ 59" _ 1 G COUNTER STAINLESS SUPPLY SPLASH VERIFY 36" 3 REQTS/DIMS H ESPRESSO LA MARZOCCO 37"X 22�� (2) 50 AMPS MACHINES X 21" 208-240 VOLTS U-C REFR BEVERAGE AIR 72" X 32" (2) UCR72AHC 72" X 34%" FULL LOAD AMP 15/60/1 - 3.0 d U-C REFRIG BEVERAGE AIR 27" X 32" (1) UCR72AHC 27" X 34% FULL LOAD AMP 15/60/1 - 2.0 K GLASS DOOR AVANTCO 29" x 32 1/4" (1) V115 - AMPS REFR A-29R-HC 54 x 821/2" 2.76 - HZ 60 L SOLID DOOR AVANTCO 29" x 32 1/4" (1) V115 - AMPS REFRIG A-29R-HC 54 . x 821/2" 2.76 - HZ 60 M MICROWAVE SOLWAVE COMM'L 22 %" X 14 1/2" (1) 1.2 CU. FT. MICROWAVE X 141/2" 1800 W 208/240 N MICROWAVE SOLWAVE COMM'L 22 %" X 14 1/2" (1) 1.2 CU. FT. MICROWAVE X 14" 1800 W 208/240 0 ICE MACHINE ICE 0 MATIC (1) VERIFY POWER U-C VERIFY SIZE & RE TS P AD]. VERIFY VERIFY VARIES PER SHELVES -4 ROOM - SEE INT ELEVS Q MOP SINK SS REGENCY 25" BOWL: 20" X 16" (1) SHT. A3.0 FOR (FLR SINK) (SINGLE BOWL) X 6" (VERIFY) LOCATION VERIFY PLUMB'G REQTS FLR MT/TOILET RM R ON -DEMAND VERIFY MFR. VERIFY VERIFY POWER & HOT WATER (SUBMIT (1) PLUMBING REQTS- MFR. DOC'S) WALL MT/TOILET RM S PULL DN VERIFY MFR. 20" X 30" w/ 30" LOCATE PER STAIR/ATTIC SUBMIT MFR. MIN HDRM @ (1) TRUSS LAYOUT ACCESS DOC'S ATTIC @ STORAGE T EXT.SS VERIFY VERIFY (3) VERIFY COUNTER U-C = UNDER COUNTER MFR=MANUFACTURER AMPS = AMPHERE DWGS = DRAWINGS REFR = REFRIGERATOR SS = STAINLESS STEEL MTD = MOUNTED SHOPS = SHOP DWGS REGTS = REQUIREMENTS MIN = MINIMUM FLR = FLOOR HDRM = HEADROOM MTD = MOUNTED DOC'S = DOCUMENTS MIN = MINIMUM Equipment Plan 1/4" = 1'-O" - AKJ Gi �P_ P/ve pl Ff f�aL�'WP IvabP' Interior Elevations 1�4n = V-0" - - V W ° C ® .e s vim.+ LL M s 0 as 00 0 y N cWMz �y� �� M LL r-L.H. r� Cn H C C O d *� �+ > y EW CL p G 3 'i W C C O OL 2020.01 _ -151.Opep NJ A Typical Wall Section TRASH ENCLOSURE:_ ct BLACK MESH/CHAIN-LINK FROM CMU TO ROOF, TYP. ALL ELEVATIONS PROVIDE GALV. STEEL GATE CANE BOLTS @ BOTH LEAVES of GATE w/ GALV. STEEL RECEIVERS SET IN CONCR. @ GRADE IN BOTH OPEN & CLOSED POSITIONS ti PROVIDE DOOR STOPS' FOR EACH LEAF of GATE @ MAX. OPEN POSITION (to Avoid Contact w/ Adj. Curbs, etc.) t4 GATE: STEEL FRAMED w/ BOX RIB METAL PANELS - See Project Manual PROVIDE ALL CONNECTORS, FLASHING, STEEL FRAMES, ETC. FOR A COMPLETE INSTALLATION ,J CANOPY @ Wall r�U.1.% YOH e/_F*110 It-Zo!.. p` _ ri MIT SHOP DRAWINGS & RELATED INFORMATION FOR: -vt4 GUTTERS & DOWNSPOUTS & METHOD OF INSTALL I IKE AS REQUIRED I I I I STEEL ROD & TURNBUCKLE - per STRUCTURAL EPDM ROOFING & FLASHING TERMINATION BAR C' CHANNEL per STRUCTURAL RIGID INSULATION SLOPE @ 1/4" / L.F. METAL DECKING CANOPY Typ. Fascia A5.0 11/2" = V-0" 'l•`i�r'../-'(. W,�a I.L - s E t; -� f des, d LIL- C, �� Zl_ = .!q x8 EAscua _PT? reP v IV 7 Hop I?— a-00TroM �i--J111 i__T _ - C I West Elevaiion east Elevation L ___J I 1/4" = 1'-0" F =TF _A South Elevation S <.-.rTi 4U.gs, vp, North E _. 1 14 . Floor Plan - Trash Enclosure 1/4" = 1'-0" - 5bi-T w/ s !'� Co`'� �?E��l. PiP� • FILE. w/ 13 I 54&CCt�A��•�oiL i South Elevation S <.-.rTi 4U.gs, vp, North E _. 1 14 . Floor Plan - Trash Enclosure 1/4" = 1'-0" - 5bi-T w/ s !'� Co`'� �?E��l. PiP� • FILE. w/ 13 I 54&CCt�A��•�oiL i p CANOPY PLAN TYP. EXTERIOR WALL CAULK JOINT 5/4 X 6, @ WINDOW HEAD FLASHING @ HEAD WINDOW PER SCHEDULE 3/4" X WD. TRIM @ JAMB & HEAD -WINDOW HEAD-[ TYP. EXT. WALL_ 11/2" = 1,-O„ WINDOW JAMB / TYP. EXT. WALL 11/2" = 1'-0" - WINDOW PER SCHEDULE — 1/2" X 13/4" APRON -- 3/4" X SILL FLASHING 2 .l" 1/2" X 4 TRIM TYP. EXTERIOR WALL 'HARDIE' SIDING MOISTURE BARRIER . _ r 1/2" PLYWD (OR PER STRUCT) 2 X 6 STUDS @ 16" O.C. R-21 BATT INSULATION ,.............. 5/8" GWB - PVA PRIMER & ENAMEL PAINT - VERIFY FINAL WALL FINISH OR MAT'L FOR PREP AREAS — FRP OR EQ WINDOW SILL / TYP. EXT. WALL _. 1 1,/2" = 1'-0" ® p N y CO ®e W Q � \ Z M c�3 A zoo tx to c 0 14,' v y _ +r W F H H Ce - 2020.0.1_ A5.Q