Loading...
20-105047-UP Arch Plans Revised-06-03-2021-V1' _ Storage ATTIC \ j '-,,__ - Attic Ventilation Required/Provided: 1)Ame AREA OVER CONDmONED SPACE 2)AmC AREA OVER NON-CONDmONED SPACE (Outdoor Seating & Walk up Service @ North Side) 31 FLAT ROOF /CANOPY@ BARISTA OlJTDOOR (Outdoor Covered Area for Baristas bv Drive Thru Lane) Areas to be Vented: 1)561 S.F. above Conditioned Floor Area 2)114 S.F. of Eave Area+ 135 5.F.@ Covered Seating/Walk-Up Service 108 S.F. @ Roof/Canonv @ Outdoor Service Area @ Drive Uo Ventilation calcs: Method/Product for Venting Area of Ventilation Rec,uired & Provided . Conditioned s-ce: 561 S.F. + 150 -4 S.F. X 144 5.1. -576 5.1. REO'D VENT AREA Ridge Vent (18 5.1. NFNL.F.) Air Vent Inc. Ridge Vent = 50 L.F. X 18 S.I./L.F. = 900 S.I. NFA (47%) SHINGLEVENT II Eave/Soffit Vent (9 NFA 5.1./L.F.) Eave Vent= 114 L.F. X 9 S.1./L.F. = 1,026 S.I. NFA (53%) Air Vent Inc.-SOFFIT VENT Non-Conditioned Space: Exterior Walk-Up & Seating @ North Side 150 S.F. + 150 = 1.0 S.F. X 144 = 144 S.I. REO'D VENT AREA Eave/Soffit Vent (9 NFA S.1./L.F.) Air Vent Inc. -SOFFIT VENT Eave Vent 12 L.F X 9 S.I./L.F. = 108 S.I. NFA ( 47% l Roof Louver Vent 60 S.I NFA Each Louver = GAF ROOF LOUVER-SSB960G 60 S.I. NFA X 2 Louvers = 120 S.I. NFA (53% l Non-Conditioned Space: Exterior Barista/Service Area @ South Side 108 S.F. + 150 -0.72 S.F. NFA R""Uired Note: See Proiect Manual for Installation of Air Vent Products Door Schedule 1 3'-0" X 7'-0"X 1¾" • INSUL. HOLLOW METAL DOOR w/ SAfffi GLASS. SEE INTERIOR ELEV'S 2 3'-0" X 7'-0" OVERHEAD DOOR •.INSULATED 't-----t-=-c==-:=-:-cccc--========,-,,===-=-=�C""""C"====------------+ 3 3'-0" X 7'-0" X 1 ¾" • SOLID CORE WOOD, PAINT. PROVIDE CLOSER & PASSAGE LOCK 4 3'-0" X 7'-0" X 1¾" • SOLID CORE WOOD, PAINT. VERIFY LOCKING REQTS I 5 3'-0",X 7'-0"X 1¾" • INSUL. HOLLOW METAL DOOR w/ SAFffi GLASS -VERIFY LOCKING REQTS t-----+-=�==-==--------=--------------------+ 6 3'-0" X 7'-0" X 1 ¾" • INSUL. HOLLOW METAL DOOR w/ SAFETY GLASS. SEE ELEVATIONS 6 3'-0" X 7'-0" X 1 ¾" • INSUL. HOLLOW METAL DOOR w/ SAFETY GLASS. SEE ELEVATIONS I Door Notes: a. PROVIDE HARDWARE FOR A COMPLETE, OPERABLE INSTALLATION INC BUT NOT LIMITED TO: LEVERS, LOCKS, DRIP CAPS, WEATHER-STRIPPING, THRESHOLDS, CLOSERS, PEEP HOLE(S), ASTRAGAL(S). KICK PLATES FLOOR MTD. DOORSTOPS. HINGES & THE LIKE. b. VERIFY SECURITY/LOCKING REQUIREMENTS WITH OWNER. c. FURNISH ITEMS NOT MENTIONED BUT NECESSARY TO COMPLETE THE WORK. d. ALL WOOD SOLID CORE DOORS TO BE AWi PREMIUM GRADE. e. ALL HARDWARE PLACEMENT TO COMPLY WITH ICC All?.1-2009 & 2015 !BC Window Schedule Mark Size A 4'-6" X 3'-6" B 3'-0" X 3'-6" C 6'-0" X 3'-6" D 6'-0" X 3'-6" E 4'-6" X 4'-0" F 4'-6" X 4'-0" G 4'-0" X 4'-6" H 3'-6" X 3'6" I 3'-6" X 3'6" J 5'-0" X 2'-0" TYPE Misc. FIXED FIXED FIXED w/ Center Mullion FIXED w/ Center Mullion SLIDING SLIDING Serving Windows SLIDING FIXED FIXED FIXED Notes 1)MILGARD SUN COAT LOW E, U�0.30 OR APPROVED EQUAL 2)VERIFY REQUIRED SECURm REQTS @ OPERABLE WINDOWS 3)GLASS TYPE TBD 4)WINDOW HEAD HEIGHT EQUAL TO DOOR HEAD HEIGHT SOFFIT MTD. LIGHTS ' ( 4) @ SOUTH/OUTDOOR SERVING = 0'sr Building -SectionA:A F,�=-�9' jb�-==_J-'- (1) @ EACH CANOPY (SURF MTD. LIGHT/UNDER ' CANOPY) i WALL MOUNT LIGHTS ' (2)@ NORTH ELEVATION . (1)@ SOUTH ELEVATION (2)@ WEST ELEVATION (2)@ EAST ELEVATION [See Floor Plan Sht. A2.0 & Exterior Elevations Sht. A3.0J "' 0 , .; ' <r ' .Roof Plan ¼" = 1'-0" ,, I ': _ cu1es=--t :·ui.Jaor: iQcor==:�av'e<---� Floor Plan ¼" = 1'-0" RIDGE VENT 35 L.F. I, ' t--- - - ---1 ----.-t-----+-t-----r-- 1--- - - ---1----1---J-- ---+--J----r------+ <au-rn� ____ _,,.·. R,6.,-i"il-1-o-N '.,.."(f. ♦ - I - rA 'y Notes: �1 -See Sht. A3.0 FOR RESTROOM Hardware Etc. (ADA COMPLIANCE, ETC.) " se.e i!:&'-f<fM�ri,-f�Al4 '5H-f. />,,t,0 -See Sht. A3.0 & SHT A4.0 FOR INTERIOR ELEVATIONS See Sht. A4.0 FOR EQUIPMENT PLAN/SCHEDULE -'f--fH---CANOPY ® -'0 0 �,_� . 'l --� .. Cl, -\J C C la la Ill -- -CL, CL, 'iii ........ !!� C !---+---+---+-----+ 0 ·;;;·s:.?l. 2020.01 2.0 OUTDOOR TRASH CANO