Loading...
21-102929-UP-Project Narrative-07-16-2021-V1 Page 1 of 2 TO: City of Federal Way DATE: July 12, 2021 FROM: Lucas Johnson Tacoma - (253) 383-2422 PROJECT NO.: 2210134 PROJECT NAME: Federal Way High School Pre-Apprenticeship Program SUBJECT: Project Narrative The project will create a space for the Pre-Apprenticeship Program, as part of the Federal Way High School (FWHS) Career and Technical Education (CTE) curriculum. The Pre-Apprenticeship Program is a partnership between the Federal Way School District (FWSD) and local labor unions, and its intent is to give students an idea of what an actual union apprenticeship programs entail. This space is an extension of the existing vocational/woodshop area in the Federal Way High School. The project (CTE Yard) is located on the existing lawn area adjacent to the existing Federal Way High School building, immediately Northwest of the Woodshop area. The CTE Yard would consist of a fenced enclosure, a canopy work area for teaching and practical demonstrations, and seating/teaching steps. The project has been designed per provisions in FWRC Chapter 19.115 – Community Design Guidelines, as noted below. 19.115.040 – Security Program The project is located on the existing FWHS campus and as such will be managed per the existing FWSD and FWHS security/safety protocols and emergency management plan. Existing site lighting provides sufficient illumination for circulation and general safety. Additional lighting will be provided within the canopy work area to support the teaching activities. The CTE Yard will be enclosed by 6’ high metal picket fence on all sides. The fence will be square picket-style fence, to match existing school fencing, approximately 4”picket spacing, painted black. No plantings are planned in the CTE Yard thus ensuring maximum visibility from all directions. 19.115.050 – Site Design – All Zoning Districts The materials for the project will be selected to match the existing materials palette on FWHS. Access into the CTE Yard will be through two vehicle gates and two pedestrian gates. All gates will be locked and monitored by the existing FHWS security networks (cameras and locks). Panic hardware will be provided on the two pedestrian gates to allow unhindered egress. The project area is centrally located on the FWHS campus and as such would not result in lighting spilling into adjacent properties. The lighting provided in the canopy area will be sufficient for teaching activities and would remain on during non-school hours for added security. Light fixtures in the canopy area will be selected with cut-off shields, to provide down lighting. The concrete seating/teaching steps would allow auditorium-type seating for demonstrations, impromptu lectures, etc. 19.115.060 – Building Design – All Zoning Districts The canopy teaching area will be a heavy timber pole barn structure, with a 52’x24’ footprint, approximately 20’ high, with a low-slope metal roof sloping in one direction. To ensure visibility, and to allow flexibility of use, the canopy structure will not have any walls, only roof. The 20’ height allows the canopy to be used for a variety of different teaching activities and practical demonstrations (wood framing, tool usage, etc). However, at 20’ high the canopy is only a fraction of the height of the existing high school building and as such recognizes the supporting and ancillary function of the canopy on the overall FSHS campus. The canopy structure will be procured and permitted at a later date as a deferred design-build installation. 19.115.070 – Building and Pedestrian Orientation – All Zoning Districts While it is located adjacent to an existing parking lot, access into the CTE Yard is provided from the walkway in front of the existing Woodshop area in FWHS. The space will be used for limited group classes and lessons and will be used for public functions. 19.115.080 – Mixed Use Residential Building in Commercial Zoning Districts Does not apply to this project. Project Memo Page 2 of 2 2210134 July 12, 2021 19.115.090 – District Guidelines Does not apply to this project. 19.115.100 – Institutional Uses Does not apply to this project. 19.115.105 – Self-Service Storage Uses Does not apply to this project. 19.115.110 – Design Criteria for Public Spaces Does not apply to this project. 19.115.115 – Design Criteria for Residential Usable Open Space and Fee-in-Lieu Option Does not apply to this project. 19.115.115 – Design for Cluster Residential Subdivision Lots Does not apply to this project. LJ/ c: Stephen Nutt and Michael Swartz (FWPS) Aleks Janjic and Connie Zheng (Bassetti)leks Janjic and Connie Zheng (Bassetti) David Nason (AHBL) Q:\2021\2210134\10_CIV\NON_CAD\REPORTS\20210712_Narrative.docx