Loading...
21-104579-Floor and Framing plan-12jan2022-V11st Floor Area Open Below -------------------------------- Total Living Area -------------------------------- Total Garage Area -------------------------------- Total Deck & Porch Area -------------------------------- Total Areas 718 Sq.Ft. - 0 Sq.Ft. ------------------- 718 Sq.Ft. ------------------- 0 Sq.Ft. ------------------- 0 Sq.Ft. ------------------- 718 Sq.Ft. Hebrews 3:4 (NIV) - For every house is built by someone, but God is the builder of everything. Square Foot Totals ("Open Below" is Space with No Stairs Underneath The Open Area) Drafting Manager: Jared Baehmer Elevation 2102 E Main #105 Puyallup, WA 98372 866.657.4371 CAD Technician: Logan Harman Engineer of Record: Ercin Sahin, P.E. Structural Works, PLLC 1412 Beach Dr NE #A Tacoma, WA 98422 253.533.0835 Design Criteria & Loads Roof Snow Load: Floor Live Load: Wind Speed (ASD): Wind Speed (ULT): Exposure: Seismic Zone: Frost Depth: 25 LBS 40 LBS 85 MPH 110 MPH B D 1'-0" Applicable Codes 2018 International Building Code (IBC) 2018 International Residential Code (IRC) 2018 Washington State Energy Code (WSEC) 3D Isometric Drawings are for illustration ONLY! N/A U-Factor (A)R-Value (A)All Climate Zones 0.042 Ceiling R-Value (E) Below Grade Wall (C,H) N/A Floor R-Value Fenestration U-Factor (B) Skylight U-Factor (B) Wood Frame Wall (G,K) Slab (D,F) R-Value & Depth N/A 49 (J) 30 (G) 21 INT 10/15/21 INT+TB 0.50 10, 2ft 0.30 0.056 0.026 0.029 A) R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table RA101.4 shall not be less than the R-value specified in the table B) The fenestration U-factor column excludes skylights. C) “10/15/21 + 5TB” means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. “10/15/21 + 5TB” shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. “5TB” means R-5 thermal break between floor slab and basement wall. D) R-10 continuous insulation is required under heated slab-on-grade floors. See Section R402.2.9.1. E) For single rafter or joist-vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth extends over the top plate of the exterior wall. F) R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall meet the requirements for thermal barriers protecting foam plastics. G) For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for climate zone 5 of ICC 400. H) Int. (intermediate framing) denotes framing and insulation as described in Section A103.2.2 including standard framing 16 inches on center, 78 percent of the wall cavity insulated and headers insulated with a minimum of R-10 insulation. Option Description Credit (R2) 2018 IECC Energy Code Infor mation Fuel Normalization Credits for the 2018 WSEC 2 For an initial heating system using a heat pump that meets federal standards for the equipment listed in Table C403.3.2(1)C or C403.3.2(2) or Air to water heat pump units that are configured to provide both heating and cooling and are rated in accordance with AHRI 550/590 1.0 (1.0) 3.6 Ductless split system heat pumps with no electric resistance heating in the primary living areas. A ductless heat pump system with a minimum HSPF of 10 shall be sized and installed to provide heat to entire dwelling unit at the design outdoor air temperature. To qualify to claim this credit, the building permit drawings shall specify the option being selected, the heated floor area calculation, the heating equipment type(s), the minimum equipment efficiency, and total installed heat capacity (by equipment type). 2.0 (3.0) Option Description Energy Credits for the 2018 WSEC Credit (R2) 3D Isometric Drawings are for illustration ONLY! 3D Isometric Drawings are for illustration ONLY!34321 35th Ave SWFederal Way, Wa 98023253-678-8578Parcel # - 3089000088Daniel MaganaPrinted On: 5/15/2021 09:22:12 Sheet: Elevation Job #: 21-0078Disclaimers:---These plans are exclusive property of Elevation (ELE) and may not be sold to any person or businesswithout expressed written consent of ELE. These plans are for one (1) time use only for ELE's customer -Magana, Daniel and to be built on the customer's site at 34321 35th Ave SW in Federal Way, Wa 98023.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation. Written permission must be obtained and granted prior to anyuse and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizSheet Index Label Pg #Title A0.0 1 Project Cover Sheet A1.1 2 1st Floor Plan A2.1 3 Elevations A4.1 4 Typical Sections S0.0 5 Structrual Notes S1.1 6 Foundation Plan S4.1 7 Structural Details S4.2 8 Structural Details S4.3 9 Structural Details Project Information Layout Sheet # 1 of 9 Project Cover Sheet A0.0 34321 35th Ave SWFederal Way, Wa 98023253-678-8578Parcel # - 3089000088Daniel MaganaPrinted On: 5/15/2021 09:22:12 Sheet: Elevation Job #: 21-0078Disclaimers:---These plans are exclusive property of Elevation (ELE) and may not be sold to any person or businesswithout expressed written consent of ELE. These plans are for one (1) time use only for ELE's customer -Magana, Daniel and to be built on the customer's site at 34321 35th Ave SW in Federal Way, Wa 98023.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation. Written permission must be obtained and granted prior to anyuse and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizB1 A2.1 WH T Tub/ShowerW01 2020 XO ExistingExistingW02 8040 XOX ExistingW03 5040 XO Egress 3068 50 Bypass H02 2668 H03 2668 40684068 4068EP 50 CFM 100 CFM SD SD 718 SQ FT 1st Floor Plan - EHD-1007181-S Proposed Scale: 1/4 in = 1 ft *** Scale Only on 24x36 or 30x42 Size Paper. Smaller Size Paper will be Not To Scale *** BATH #1 CLOSET #1 CLOSET #2 PANTRY BEDROOM #1 Bedroom #1 11'-2" x 15'-0" 8' Plate Height Flooring - Carpet CLOSET #3 KITCHEN LIVING ROOM ENTRY Living Room 15'-0" x 16'-3" 8' Plate Height Flooring - Laminate Kitchen 6'-7" x 12'-9" 8' Plate Height Window relocated from bedroom LIVING AREA A1 A2.1 A A2.1 A A2.1 B A2.1 B A2.1 D1 A2.1 C5 A2.1 Relocate W05 5030 XO W01 5030 XO DemoDemoW04 4030 XO Replace D01 3068 1st Floor Plan - EHD-1007181-S As-Built Scale: 1/4 in = 1 ft Slab 29'-0" x 29'-0" 8' Plate Height *** Scale Only on 24x36 or 30x42 Size Paper. Smaller Size Paper will be Not To Scale ***DemoModifySLAB Relocate to bathroom Replace w/ 50x40 for egress Raise to meet new floor level 1st Floor Room Schedule Room Name Floor Finish Ceiling Height Sq Ft**Dimensions** Living Room Flooring - Laminate 95 1/2"292 15'-0" x 16'-3" Bedroom #1 Flooring - Carpet 95 1/2"193 11'-2" x 15'-0" Closet #3 Flooring - Carpet 95 1/2"18 2'-0" x 7'-2" Bath #1 Flooring - Tile 95 1/2"48 8'-3" x 4'-11" Closet #1 Flooring - Carpet 95 1/2"18 3'-0" x 4'-10" Closet #2 Flooring - Carpet 95 1/2"12 4'-11" x 2'-0" Pantry Flooring - Laminate 95 1/2"10 1'-5" x 4'-10" Kitchen Flooring - Laminate 95 1/2"96 6'-7" x 12'-9" Entry Flooring - Laminate 95 1/2"31 7'-4" x 3'-8" Totals:718 *Ceiling Height for Garage/Basement is from Top of Slab to Top of Sill Plate ** All Square Footage, Room Dimensions & Ceiling Heights are Approximate Window Schedule Number Window Info Floor Width Height Sq Ft Room Name**Top Height Trim Size Egress Tempered U-Factor SHGC Comments W01 2020 XO 1 24 "24 "4.0 Bath #1 87"3/4"x3 1/2"0.27 0.25 W02 8040 XOX 1 96 "48 "32.0 Living Room 87"3/4"x3 1/2"0.27 0.25 W03 5040 XO 1 60 "48 "20.0 Bedroom #1 87"3/4"x3 1/2"Yes 0.27 0.25 Totals:56.0 Interior Door Schedule Number Size Floor Width Height Sq Ft Room Name Jamb Size Trim Size Type Hinge Side Swing Side Comments H01 5068 R IN 1 60 "80 "33.33 Bedroom #1/Closet #3 3/4"x4 1/2"1/2"x3 1/2"Slider R In H02 2668 R IN 1 30 "80 "16.67 Bedroom #1/Living Room 3/4"x4 1/2"1/2"x3 1/2"Hinged R In H03 2668 L IN 1 30 "80 "16.67 Living Room/Bath #1 3/4"x4 1/2"1/2"x3 1/2"Hinged L Out H04 4068 L/R 1 48 "80 "26.67 Living Room/Closet #1 3/4"x4 1/2"1/2"x3 1/2"4 Dr. Bifold L/R In H05 4068 L/R 1 48 "80 "26.67 Living Room/Closet #2 3/4"x4 1/2"1/2"x3 1/2"4 Dr. Bifold L/R In H06 4068 L/R 1 48 "80 "26.67 Kitchen/Pantry 3/4"x4 1/2"1/2"x3 1/2"4 Dr. Bifold L/R In Totals:146.68 718 Sq.Ft. 109.0 Sq.Ft. 15.18 % Floor Areas 1st Floor Living Area = Total Living Space = Total Glazing Area = Glazing Percentage = 718 Sq.Ft. **Glazing Calc have Open Below Areas included. **Windows Located in Non-Heated Rooms are not included in Glazing Percentages Layout Sheet # 2 of 9 1st Floor Plan A1.1 34321 35th Ave SWFederal Way, Wa 98023253-678-8578Parcel # - 3089000088Daniel MaganaPrinted On: 5/15/2021 09:22:12 Sheet: Elevation Job #: 21-0078Disclaimers:---These plans are exclusive property of Elevation (ELE) and may not be sold to any person or businesswithout expressed written consent of ELE. These plans are for one (1) time use only for ELE's customer -Magana, Daniel and to be built on the customer's site at 34321 35th Ave SW in Federal Way, Wa 98023.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation. Written permission must be obtained and granted prior to anyuse and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.biz*** Scale Only on 24x36 or 30x42 Size Paper. Smaller Size Paper will be Not To Scale *** 3/4" Cornerboard Horizontal Lap Siding Elevation C 5 - EHD-1007181-S Proposed Scale: 1/4 in = 1 ft -(1'-0") - Min Frost Depth Top of Wall Plate Above FFL - 8' Approximate Height Above FFL - 11'-9" Minimum 6" Grade to Wood Top of Sub Floor FFL - 0' Continuous Ridge Vent Architectural Composition Roofing Class "B" Minimum Required w/ 7/16" Plywood Roof Sheathing 11'-9"6"13'-9"18"12'-3"8'*** Scale Only on 24x36 or 30x42 Size Paper. Smaller Size Paper will be Not To Scale *** 3/4" Cornerboard Horizontal Lap Siding Elevation D1 - EHD-1007181-S Proposed Scale: 1/4 in = 1 ft -(1'-0") - Min Frost Depth Top of Wall Plate Above FFL - 8' Approximate Height Above FFL - 11'-9" Minimum 6" Grade to Wood Top of Sub Floor FFL - 0' Continuous Ridge Vent Architectural Composition Roofing Class "B" Minimum Required w/ 7/16" Plywood Roof Sheathing 11'-9"6"13'-9"18"12'-3"8'12'-3"18"*** Scale Only on 24x36 or 30x42 Size Paper. Smaller Size Paper will be Not To Scale ***8'13'-9"11'-9"6" -(1'-0") - Min Frost Depth Top of Wall Plate Above FFL - 8' Approximate Height Above FFL - 11'-9" Minimum 6" Grade to Wood Top of Sub Floor FFL - 0' Continuous Ridge Vent Architectural Composition Roofing Class "B" Minimum Required w/ 7/16" Plywood Roof Sheathing Cross Section A - EHD-1007181-S Proposed Scale: 1/4 in = 1 ft 12'-3"18"*** Scale Only on 24x36 or 30x42 Size Paper. Smaller Size Paper will be Not To Scale *** -(1'-0") - Min Frost Depth Top of Wall Plate Above FFL - 8' Approximate Height Above FFL - 11'-9" Minimum 6" Grade to Wood Top of Sub Floor FFL - 0' Continuous Ridge Vent Architectural Composition Roofing Class "B" Minimum Required w/ 7/16" Plywood Roof Sheathing Cross Section B - EHD-1007181-S Proposed Scale: 1/4 in = 1 ft8'13'-9"11'-9"6"*** Scale Only on 24x36 or 30x42 Size Paper. Smaller Size Paper will be Not To Scale *** 3/4" Cornerboard Horizontal Lap Siding Elevation B1 - EHD-1007181-S Proposed Scale: 1/4 in = 1 ft -(1'-0") - Min Frost Depth Top of Wall Plate Above FFL - 8' Approximate Height Above FFL - 11'-9" Minimum 6" Grade to Wood Top of Sub Floor FFL - 0' Continuous Ridge Vent Architectural Composition Roofing Class "B" Minimum Required w/ 7/16" Plywood Roof Sheathing 11'-9"6"13'-9"18"12'-3"8'*** Scale Only on 24x36 or 30x42 Size Paper. Smaller Size Paper will be Not To Scale *** 3/4" Cornerboard Horizontal Lap Siding Elevation A1 - EHD-1007181-S Proposed Scale: 1/4 in = 1 ft -(1'-0") - Min Frost Depth Top of Wall Plate Above FFL - 8' Approximate Height Above FFL - 11'-9" Minimum 6" Grade to Wood Top of Sub Floor FFL - 0' Continuous Ridge Vent Architectural Composition Roofing Class "B" Minimum Required w/ 7/16" Plywood Roof Sheathing 11'-9"6"13'-9"18"12'-3"8'Layout Sheet # 3 of 9 Elevations A2.1 34321 35th Ave SWFederal Way, Wa 98023253-678-8578Parcel # - 3089000088Daniel MaganaPrinted On: 5/15/2021 09:22:13 Sheet: Elevation Job #: 21-0078Disclaimers:---These plans are exclusive property of Elevation (ELE) and may not be sold to any person or businesswithout expressed written consent of ELE. These plans are for one (1) time use only for ELE's customer -Magana, Daniel and to be built on the customer's site at 34321 35th Ave SW in Federal Way, Wa 98023.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation. Written permission must be obtained and granted prior to anyuse and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizS p ace No t Use d 1/2" Section - Space Not Used Scale: No Scale S e e R o o f P la n fo r P itc h Typical Wall Construction . 1 - Horizontal Siding on Exterior 2 - Tyvek Building Wrap 3 - 7/16" Plywood OSB 4 - 2x Studs @ " oc 5 - R-21 Insulation w/ Vapor Barrier 6 - 7/16" GWB on Interior Double Top Plate R-49 Blow-In Insulation R-38 High Density Batt Insulation 6 Mil Black Poly Visqueen8" x 16" Footing #Evaluation Error# 1'-0" Frost Depth Required 4" Concrete Slab Typical FDN Construction (<48") 1 - PT 2x6 Sill Plate 2 - 1/2" AB's per Engineering 3 - (1) #4 Rebar (Horiz) in Top 1/3 of stemwall 4 - (1) #4 Rebar (Horiz) in Bot 1/3 of stemwall 5 - (1) #4 Rebar (Vert) at 48" oc 6 - (2) #4 Rebar (Horiz) in Footings 7 - See Engineering for Foundation Requirements for Stemwalls over 48" of Unbalanced Fill. Typical Roof Construction . 1 - 7/16" Plywood Roof Sheathing - See Engineering for Nailing Pattern 2 - R-38 High Density Batt Insulation & R-49 Blow-In Insulation 3 - 15# Asphaltic Roof Paper 4 - Pre-Manufactured Trusses @ " oc 5 - 5/8" GWB Drywall on Ceiling 6 - 5/4" Fascia Section - 1 Story Garage Scale: No Scale S pa ce No t Used 1/2" Section - Space Not Used Scale: No Scale Layout Sheet # 4 of 9 Typical Sections A4.1020201010303 34321 35th Ave SWFederal Way, Wa 98023253-678-8578Parcel # - 3089000088Daniel MaganaPrinted On: 5/15/2021 09:22:13 Sheet: Elevation Job #: 21-0078Disclaimers:---These plans are exclusive property of Elevation (ELE) and may not be sold to any person or businesswithout expressed written consent of ELE. These plans are for one (1) time use only for ELE's customer -Magana, Daniel and to be built on the customer's site at 34321 35th Ave SW in Federal Way, Wa 98023.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation. Written permission must be obtained and granted prior to anyuse and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizLayout Sheet # 5 of 9 Structrual Notes S0.0 GENERAL NOTES AREA ROOF OTHER ROOMS FLOORS STAIRS DECKS DESIGN DEAD LOAD 15 PSF ACTUAL ACTUAL ACTUAL LIVE LOAD 25 PSF (SNOW) 40 PSF (2) 40 PSF (OR 300#/TREAD) 60 PSF (1) LIVE LOAD REDUCTION NOT PERMITTED EXCEPT AS NOTED IN IBC SECTION 1607.10. (2) 30 PSF FOR SLEEPING AREAS LATERAL FORCES WIND: IBC - EXPOSURE CATEGORY = B - BASIC WIND SPEED, (3 SEC. GUST), VULT = 110 MPH - WIND IMPORTANCE FACTOR, Iw = 1.0 - OCCUPANCY BUILDING CATEGORY PER TABLE 1-1 = II - INTERNAL PRESSURE COEFFICIENT (ENCLOSED) = ± 0.18 - TOPOGRAPHIC FACTOR KZT = 1.00 SEISMIC: WELDING STRUCTURAL STEEL: WELD IN ACCORDANCE WITH "STRUCTURAL WELDING CODE" AWS D1.1. ELECTRODES: USE E70 ELECTRODES. GENERAL REQUIREMENTS ADHESIVE ANCHOR RODS: ASTM F1554, GRADE 36 UNLESS NOTED OTHERWISE. SEISMIC IMPORTANCE FACTOR, e = 1.0 RISK CATEGORY OF BUILDING PER TABLE 1.5-1 = D SPECTRAL RESPONSE ACCELERATIONS Ss = 1.346 & S1 = 0.463 SITE CLASS PER TABLE 20.3-1 = D DESIGN SPECTRAL RESPONSE ACCELERATIONS Sds = 0.897 SEISMIC DESIGN CATEGORY = D ANALYSIS PROCEDURE USED = SIMPLIFIED LATERAL FORCE ANALYSIS RESPONSE MODIFICATION FACTOR PER TABLE 12.2-1, R = 6.5 I CONCRETE ANCHORS: - ADHESIVE ANCHORS: HILTI HIT-HY 200 (ICC-ESR-3187) *CONCRETE SHALL BE A MINIMUM OF 21 DAYS OLD AT TIME OF INSTALLATION. *CONCRETE SHALL BE IN THE TEMPERATURE RANGE AS REQUIRED BY THE CONCRETE MANUFACTURER. *HOLE SHALL BY HAMMER-DRILLED ONLY. *HOLE SHALL BE DRY AT TIME OF INSTALLATION. *INSTALLER OF HORIZONTAL OR UPWARDLY INCLINED (ANY POSITION EXCEPT DIRECTLY DOWNWARD) ANCHORS SHALL ALSO BE CERTIFIED BY THE ACI/ CRSI ADHESIVE ANCHOR INSTALLER CERTIFICATION PROGRAM. STRUCTURAL STEEL DETAILING, FABRICATION AND ERECTION ALL WORKMANSHIP SHALL CONFORM TO THE AISC MANUAL OF STEEL CONSTRUCTION, 14TH EDITION. MATERIAL PROPERTIES WIDE FLANGE SECTIONS: ASTM A992 (Fy = 50 KSI) OTHER SHAPES AND PLATES: ASTM A36 (Fy = 36 KSI) TYP. U.N.O.; ASTM A572 (Fy = 50 KSI) WHERE INDICATED HOLLOW STRUCTURAL SECTIONS: RECTANGULAR & SQUARE - ASTM A500 GRADE B (Fy = 46 KSI) ROUND - ASTM A500 GRADE B (Fy = 42 KSI) STRUCTURAL STEEL PIPES: ASTM A53, GRADE B, TYPE E OR S (Fy = 35 KSI) MACHINE BOLTS (M.B.): ASTM A307, GRADE A ANCHOR BOLTS (A.B.): ASTM F1554, GRADE 55, UNLESS OTHERWISE NOTED, ASTM F1554, GRADE 105 WHERE INDICATED. ANY DISCREPANCIES FOUND AMONG THE DRAWINGS, THE SPECIFICATIONS, THESE GENERAL NOTES AND THE SITE CONDITIONS SHALL BE REPORTED TO THE ARCHITECT, WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING. ANY WORK DONE BY THE GENERAL CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE GENERAL CONTRACTOR'S RISK. THE GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE DIMENSIONS AMONG ALL DRAWINGS PRIOR TO PROCEEDING WITH ANY WORK OR FABRICATION. THE STRUCTURE HAS BEEN DESIGNED TO RESIST CODE SPECIFIED VERTICAL AND LATERAL FORCES AFTER THE CONSTRUCTION OF ALL STRUCTURAL ELEMENTS HAS BEEN COMPLETED. STABILITY OF THE STRUCTURE PRIOR TO COMPLETION IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THIS RESPONSIBILITY INCLUDES BUT IS NOT LIMITED TO JOB SITE SAFETY; ERECTION MEANS, METHODS, AND SEQUENCES; TEMPORARY SHORING, FORMWORK, BRACING; USE OF EQUIPMENT AND CONSTRUCTION PROCEDURES. CONSTRUCTION OBSERVATION BY THE STRUCTURAL ENGINEER IS FOR GENERAL CONFORMANCE WITH DESIGN ASPECTS ONLY AND IS NOT INTENDED IN ANY WAY TO REVIEW THE CONTRACTOR'S CONSTRUCTION PROCEDURES. STANDARDS ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) AS AMENDED AND ADOPTED BY THE LOCAL BUILDING OFFICIAL OR APPLICABLE JURISDICTION. APPLICABLE STRUCTURAL PROVISIONS: • 2018 INTERNATIONAL BUILDING CODE (IBC) DESIGN CRITERIA VERTICAL LOADS SNOW: (MINIMUM ROOF SNOW LOAD = 25 PSF) Pg = 25 PSF = GROUND SNOW LOAD Pf = 0.7CeCt IsPg = FLAT ROOF SNOW LOAD Ps = CsPf = SLOPED ROOF SNOW LOAD Is = 1.0 Ce = 1.0, Ct = 1.0, Cs = 25 PSF THE BUILDING MEETS THE CRITERIA TO USE THE "SIMPLIFIED ENVELOPE PROCEDURE" PER ASCE 7-16. SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE SPECIFIED BELOW, SHALL BE SUBMITTED FOR APPROVAL A MINIMUM OF 2 WEEKS PRIOR TO BID, ALONG WITH CALCULATIONS THAT ARE PREPARED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER (LICENSED IN THE STATE IN WHICH THE PROJECT OCCURS) DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING EQUIVALENT PERFORMANCE VALUES (MINIMUM) OF THE SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE AND/OR STANDARD(S) AS REQUIRED BY THE BUILDING CODE. - SCREW ANCHORS: KWIK HUS-EZ (ICC ESR-3027) BY HILTI, INC. OR TITEN HD (ICC ESR-2713) BY SIMPSON STRONG TIE, INC. - EXPANSION ANCHORS: KWIKBOLT TZ (ICC ESR-1917) BY HILTI, INC. OR STRONG-BOLT 2 (ICC ESR-3037) BY SIMPSON STRONG TIE, INC. FINISH : STRUCTURAL STEEL SHALL BE PRIMER PAINTED, UNLESS NOTED OTHERWISE. WHERE STRUCTURAL STEEL IS NOTED TO BE GALVANIZED, IT SHALL BE HOT-DIP GALVANIZED IN ACCORDANCE WITH ASTM A123, A384, AND A385. CERTIFICATION : ALL WELDING SHALL BE PERFORMED BY WABO/AWS CERTIFIED WELDERS. WELDERS SHALL BE PREQUALIFIED FOR EACH POSITION AND WELD TYPE WHICH THE WELDER WILL BE PERFORMING. ITEM SLAB ON GRADE FOUNDATIONS - UNO STEM WALLS CONCRETE MIX NOTES: GROUT REINFORCING STEEL POST-INSTALLED ANCHORS DESIGN f'c (PSI) (AT 28 DAYS U.N.O.) 2500 2500 2500 MAX W/C RATIO 0.45 0.50 0.45 100 -- 100 AGGREGATE GRADING ASTM AASHTO 57 OR 67 1 NOTES CONCRETE FOUNDATION DESIGN CRITERIA SOIL BEARING PRESSURE: 1500 PSF (ASSUMED)* ACTIVE PRESSURE - RESTRAINED: 55 PCF +14H SEISMIC SURCHARGE (ASSUMED) ACTIVE PRESSURE - UNRESTRAINED: 35 PCF +6H SEISMIC SURCHARGE (ASSUMED) PASSIVE RESISTANCE: 200 PCF (INCLUDES F.O.S. ≥ 1.5) (ASSUMED) COEFFICIENT OF FRICTION: .35 (INCLUDES F.O.S. ≥ 1.5) (ASSUMED) FREE DRAINING BACKFILL MATERIAL FOR RETAINING & BASEMENT WALLS WITH A MAXIMUM DUST RATIO % PASSING U.S. NO. 200 SIEVE % PASSING U.S. NO. 40 SIEVE = 2/3 MAX. ALL FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH OR "STRUCTURAL BACKFILL". NATIVE EARTH BEARING SHALL BE SURFACE COMPACTED. AREAS OVER-EXCAVATED SHALL BE BACKFILLED WITH LEAN CONCRETE (F'c= 2000 PSI) OR "STRUCTURAL BACKFILL". AREAS DESIGNATED "STRUCTURAL BACKFILL" SHALL BE FILLED WITH APPROVED WELL-GRADED BANKRUN MATERIAL. MAXIMUM SIZE OF ROCK 4". FROZEN SOIL, ORGANIC MATERIAL AND DELETERIOUS MATTER NOT ALLOWED. COMPACT TO AT LEAST 95% OF ITS MAXIMUM DENSITY AS DETERMINED BY ASTM D1557. PROVIDE DRAINAGE AND DEWATERING AROUND ALL WORK TO AVOID WATER-SOFTENED FOOTINGS. A CLEAN, FREE DRAINING, WELL GRADED GRANULAR MATERIAL CONFORMING TO ASTM D2487 GW OR SW WHOSE MAXIMUM PARTICLE SIZE DOES NOT EXCEED 3/4" AND WHOSE FINES CONTENT (MATERIAL PASSING THE NO. 200 SIEVE) DOES NOT EXCEED 5%, CONCRETE: MODERATE WEATHERING POTENTIAL SHALL BE MADE WITH PORTLAND CEMENT SHALL BE MADE WITH PORTLAND CEMENT ASTM C-150 TYPE II OR TYPE I, COARSE AND FINE AGGREGATE ASTM C-33, WATER CLEAN AND POTABLE AND SHALL BE READY MIXED PER ASTM C-94. NO ALUMINUM (CONDUIT, MISCELLANEOUS ITEMS, ETC.) SHALL BE EMBEDDED IN ANY CONCRETE. COORDINATE FORMWORK AND FINISH TYPES ACCEPTABLE TO THE OWNER. 1. FIBROUS CONCRETE REINFORCEMENT SHALL BE "FIBERMESH" MANUFACTURED BY PROPEX CONCRETE SYSTEMS OR PRE-APPROVED EQUAL. DOSAGE SHALL FOLLOW MANUFACTURER'S RECOMMENDATION BUT NOT LESS THAN 1.5 LB/CU. YD. 2. PROVIDE 3000 PSI AT 28 DAYS MINIMUM FOR DURABILITY AT BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS, PORCHES, CARPORT SLABS AND STEPS EXPOSED TO THE WEATHER AND FOR ALL GARAGE FLOOR SLABS. CONCRETE SHALL BE AIR ENTRAINED CONFORMING TO ASTM C-260. TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL NOT BE LESS THAN 5% OR MORE THAN 7%. PLACE CONCRETE: PER ACI 304 AND CONFORM TO ACI 305 AND 306 FOR HOT AND COLD WEATHER PLACEMENT AND CURING PROTECTION. USE INTERIOR MECHANICAL VIBRATORS WITH 7000 RPM MINIMUM FREQUENCY. DO NOT OVER-VIBRATE. CONCRETE SHALL BE POURED MONOLITHICALLY BETWEEN CONSTRUCTION OR EXPANSION JOINTS. PROTECT ALL FRESHLY PLACED CONCRETE FROM PREMATURE DRYING, EXCESSIVE HOT OR COLD TEMPERATURE FOR SEVEN DAYS AFTER POURING. NON-SHRINK GROUT: GROUT SHALL CONFORM TO CRD-C621. F'c = 5000 PSI IN 28 DAYS. FILL OR PACK ENTIRE SPACE UNDER PLATES OR SHAPES. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION, INSTALLATION, AND CURING. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60. DETAIL, FABRICATE AND PLACE PER ACI 315 AND ACI 378. LAP SPLICES SHALL BE 48 BAR DIAMETERS UNLESS NOTED OTHERWISE. PROVIDE CORNER BARS AT ALL HORIZONTAL BARS IN FOOTINGS AND WALLS. WELDED WIRE REINFORCEMENT SHALL CONFORM TO A185. LAP ONE FULL MESH ON SIDES AND ENDS BUT NOT LESS THAN 8 INCHES. PLACE AT MID-DEPTH OF SLAB OR AS SHOWN. POST-INSTALLED ANCHORS: SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE STRUCTURAL ENGINEER PRIOR TO INSTALLING POST-INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST- IN-PLACE ANCHORS. CARE SHALL BE TAKEN IN PLACING POST-INSTALLED ANCHORS TO AVOID CONFLICTS WITH REBAR. INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. INSTALLER SHALL BE QUALIFIED AND TRAINED BY THE MANUFACTURER. HOLES SHALL BE HAMMER DRILLED ONLY (ROTARY DRILLED ONLY AT UNREINFORCED MASONRY - NO HAMMER TOOLS). MIN FLASH OR SLAG (PCY) 57 OR 67 57 OR 67 ITEM TYPE. CONNECTION GENERAL REQUIREMENTS: PROVIDE MINIMUM NAILING PER IBC TABLE 2304.10.1 OR MORE, AS OTHERWISE SHOWN. STAGGER ALL NAILING TO PREVENT SPLITTING OF WOOD MEMBERS. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESERVATIVE TREATED WITH THE EXCEPTION OF INTERIOR CONCRETE TOPPINGS ON WOOD FLOOR SYSTEMS. HOLES AND CUTS IN 3x OR 4x PLATES SHOULD BE TREATED WITH A 9% SOLUTION OF COPPER NAPHTHENATE. BOLT HOLES IN WOOD MEMBERS SHALL BE A MINIMUM OF 1/32" TO A MAXIMUM OF 1/16" LARGER THAN THE BOLT DIAMETER. PROVIDE CUT WASHERS WHERE BOLT HEADS, NUTS AND LAG SCREW HEADS BEAR ON WOOD. PROVIDE A MINIMUM 3"x3"x0.229" PLATE WASHER ON ALL ANCHOR BOLTS WHICH CONNECT MUD SILLS TO FOUNDATION. DO NOT NOTCH OR DRILL STRUCTURAL MEMBERS, EXCEPT AS ALLOWED BY IBC SECTIONS 2308.4.2.4, 2308.5.9, 2308.5.10 AND 2308.7.4 OR AS RESTRICTED BY PLANS OR DETAILS, OR AS APPROVED PRIOR TO INSTALLATION. REFER TO PRESERVATIVE TREATED WOOD REQUIREMENTS IN THESE GENERAL NOTES FOR GALVANIZING REQUIREMENTS FOR CONNECTORS AND FASTENERS. FASTENING SCHEDULE FOR WOOD STRUCTURAL MEMBERS (UNLESS NOTED OTHERWISE ON PLANS) FRAMING CONNECTORS: SHALL HAVE ICC APPROVAL AND BE MANUFACTURED BY SIMPSON STRONG-TIE COMPANY, SAN LEANDRO, CA., OR PRE-APPROVED EQUAL. PROVIDE MAXIMUM SIZE AND QUANTITY OF NAILS OR BOLTS PER MANUFACTURER, EXCEPT AS NOTED OTHERWISE. PROVIDE LEAD HOLES AS REQUIRED TO PREVENT SPLITTING OF WOOD MEMBERS. REFER TO PRESERVATIVE TREATED WOOD REQUIREMENTS IN THESE GENERAL NOTES FOR GALVANIZING REQUIREMENTS FOR CONNECTORS AND FASTENERS. LAG SCREWS: SHALL CONFORM TO ANSI/ASME STANDARD B18.2.1. LAG SCREWS SHALL BE OF A DIAMETER INDICATED ON DRAWINGS WITH A MINIMUM OF 8x DIA. EMBEDMENT IN SUPPORTING MEMBER UNLESS NOTED OTHERWISE. CLEARANCE HOLE FOR THE SHANK SHALL BE THE SAME DIAMETER AS THE SHANK AND THE SAME DEPTH OF PENETRATION AS THE UNTHREADED PORTION OF THE SHANK. THE LEAD HOLE FOR THE THREADED PORTION SHALL HAVE A DIAMETER EQUAL TO 60 TO 75 PERCENT OF THE SHANK DIAMETER AND A LENGTH EQUAL TO AT LEAST THE LENGTH OF THE THREADED PORTION. THE THREADED PORTION OF THE SCREW SHALL BE INSERTED IN ITS LEAD HOLE BY TURNING WITH A WRENCH. SOAP OR OTHER LUBRICANT SHALL BE USED ON THE SCREWS OR IN THE LEAD HOLE TO FACILITATE INSERTION AND PREVENT DAMAGE TO THE SCREW. LAG SCREWS SHALL NOT BE DRIVEN WITH A HAMMER. REFER TO PRESERVATIVE TREATED WOOD REQUIREMENTS IN THESE GENERAL NOTES FOR GALVANIZING REQUIREMENTS FOR CONNECTORS AND FASTENERS. METAL-PLATE-CONNECTED WOOD TRUSSES: SHALL BE MANUFACTURED AND INSTALLED WITHIN THE JURISDICTION REQUIREMENTS, AND DESIGNED AND DETAILED IN ACCORDANCE WITH ANSI/TP-1, INCLUDING BRACING AND WIND UPLIFT. PROVIDE 2x6 TOP CHORDS, AND 2x4 BOTTOM CHORDS AND WEBS, UNLESS COORDINATED AND APPROVED. TRUSSES SHALL BE DESIGNED TO CARRY THE LOADS LISTED IN THE DESIGN CRITERIA AND ANY ADDITIONAL LOADS INDICATED ON THE FRAMING PLANS AND DETAILS. TRUSSES INDICATED ON PLANS ARE FOR TYPICAL UNIFORMLY LOADED CONDITIONS. MANUFACTURER SHALL PROVIDE ADDITIONAL OR SPECIAL TRUSSES AS REQUIRED TO SUPPORT SPECIAL LOADING CONDITIONS AS INDICATED ON DRAWINGS. PROVIDE INSTALLATION FRAMING PLANS AND DRAWINGS. PROVIDE CERTIFICATE OF CONFORMANCE FROM AN INDEPENDENT TESTING LABORATORY OR A LICENSED PROFESSIONAL ENGINEER CERTIFYING THAT THEY HAVE INSPECTED THE FINISHED TRUSSES AND THAT ALL TRUSSES ARE CONSTRUCTED IN CONFORMANCE WITH THE TRUSS DESIGN DRAWINGS. I-JOISTS: SHALL BE APA EWS PERFORMANCE RATED I-JOISTS (PRI) OR PRE-APPROVED EQUAL. I-JOISTS SHALL BE MANUFACTURED IN CONFORMANCE WITH APA PRI-400 CONFORMING TO APPROVED SHOP AND INSTALLATION DRAWINGS. CEILING JOIST TO PARALLEL RAFTER CEILING JOIST: LAP OVER PARTITION BLOCKING TO RAFTER RIM BOARD TO RAFTER TOP PLATE TO TOP PLATE TOP PLATE AT INTERSECTIONS HEADER TO HEADER TOP OR BOTTOM PLATE TO STUD RAFTER OR TRUSS TO TOP PLATE CEILING JOIST TO TOP PLATE STUD TO SOLE PLATE BOTTOM PLATE TO FLOOR JOIST AT BRACED PANEL JOISTS TO TOP PLATE, SILL OR GIRDER BRIDGING TO JOIST BLOCKING TO JOISTS BLOCKING TO TOP PLATE RIM JOIST TO JOIST RIM JOIST TO SILL OR TOP PLATE CONTINUOUS HEADER TO STUD BUILT-CORNER STUDS BUILT-UP BEAMS (PER LAYER) RAFTERS TO RIDGE BOARD RAFTERS TO HIP FACE NAIL FACE NAIL FACE NAIL TOENAIL END NAIL FACE NAIL FACE NAIL FACE NAIL FACE NAIL FACE NAIL END NAIL TOE NAIL & END NAIL TOE NAIL TOE NAIL TOE NAIL TOE NAIL FACE NAIL CONNECTOR CONNECTOR FACE NAIL FACE NAIL TOENAIL & CONNECTOR TOENAIL COLLAR TIE TOP PLATE LAP STUD TO STUD TOE NAIL & FACE NAIL TOE NAIL & FACE NAIL TOE NAIL & FACE NAIL (3) 16d H2.5 @ 48" O.C. (3) 16d (3) 16d (3) 16d (3) 8d (3) 8d (2) 16d (2) 16d @ 12" O.C. (4) 16d (8) 16d (2) 16d @ 24" O.C. 16d @ 16" O.C. EA. EDGE (2) 16d (4) 8d (2) 16d 16d @ 16" O.C. (3) 16d @ 16" O.C. (4) 8d (2) 8d (3) 8d (3) 8d (3) 16d A35 @ 24" O.C. A35 16d @ 24" O.C. 16d @ 16" O.C. EA. EDGE (4) 16d (3) 16d (4) 16d (3) 16d CARPENTRY: PENNYWEIGHT DIAMETER (IN) 8d COMMON WIRE 8d "DIPPED GALV. BOX" 8d "SHINY BOX" 12 GA. STAPLES 14 GA. STAPLES 15 GA STAPLES 10d COMMON WIRE 10d "HOT DIPPED GALV. BOX" 10d "SHINY BOX" 0.131 0.131 0.113 0.1055 0.080 0.072 0.148 0.148 0.128 2-1/2 1-1/2* 1-1/2* 3 *BASED ON 15/32" PLYWOOD OR OSB. **REFERENCE TO COLOR CODED NAILS PER TRACKERS SYSTEM. MINIMUM DESIGN VALUES: 1. 2x LVL: Fb = 1700 PSI, Fv = 285 PSI, E = 1300 KSI 2. 1-3/4" LVL: Fb = 2600 PSI, Fv = 285 PSI, E = 1800 KSI 3. 3-1/2" LVL: Fb = 2900 PSI, Fv = 285 PSI, E = 2000 KSI 4. 5-1/4" LVL: Fb = 2900 PSI, Fv = 285 PSI, E = 2000 KSI 5. RIMBOARD:APA/EWS PERFORMANCE RATED RIM (PRR-401) 1-1/4" MINIMUM THICKNESS PRESERVATIVE TREATED WOOD REQUIREMENTS: TREATMENTS OTHER THAN THOSE LISTED BELOW ARE NOT PERMITTED. 6 6 4-1/2 6 6 5 6 6 4-1/2 4 4 3 5-1/2 4 3 4 4 3 3 3 2-1/2 4 3 2-1/2 3 3 2-1/4 BLUE - YELLOW - - - PURPLE - WHITE FOR DIAPHRAGM OR SHEAR WALL NAILING THE FOLLOWING FASTENER TYPES MAY BE USED AT EQUIVALENT SPACING TO THAT SPECIFIED ON PLANS: NAILS: CONNECTION DESIGNS ARE BASED ON "COMMON WIRE" NAILS WITH THE FOLLOWING PROPERTIES: WOOD SHEATHING (STRUCTURAL): SHEATHING SHALL BE PLYWOOD OR ORIENTED STRAND BOARD. PLYWOOD SHEATHING SHALL BE 5-PLY MINIMUM WHERE INDICATED AS 3/4" OR THICKER. WOOD SHEATHING SHALL BE "STRUCTURAL I" CONFORMING TO PS1-09 AND/OR PS2-10. ALL PANELS SHALL BEAR THE STAMP OF AN APPROVED GRADING AGENCY. SPAN RATING SHALL BE PROVIDED AS FOLLOWS: ROOF FRAMING AT 32"O.C. (48/24); ROOF FRAMING AT 24"O.C. (32/16); WALLS (32/16); FLOORS (48/24) ALL WOOD SHEATHED WALLS SHALL BE BLOCKED AT ALL PANEL EDGES UNLESS NOTED OTHERWISE. GLUE-LAMINATED MEMBERS: CONFORM TO ANSI/AITC A190.1. MEMBERS SHALL BE COMBINATION 24F-V4 DOUGLAS FIR (DF) FOR SIMPLE SPANS AND 24F-V8 DF FOR CANTILEVERED SPANS (Fb=2400 PSI, Fv=265 PSI, E= 1.8X10^6 PSI) AND DF COMBINATION 2 FOR COLUMNS. ARCHITECTURAL APPEARANCE GRADE WHERE EXPOSED TO VIEW; INDUSTRIAL APPEARANCE GRADE WHERE NOT EXPOSED TO VIEW. ALL MEMBER TO HAVE EXTERIOR GLUE AND HAVE AITC OR APA-EWS STAMP. CAMBER AS SHOWN ON STRUCTURAL DRAWINGS. FRAMING LUMBER: STANDARDS. EACH PIECE SHALL BEAR THE GRADE TRADEMARK OF THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB), WESTERN WOOD PRODUCTS ASSOCIATION (WWPA), OR OTHER AGENCY ACCREDITED BY THE AMERICAN LUMBER STANDARD COMMITTEE (ALSC) TO GRADE UNDER ALSC CERTIFIED GRADING RULES. SPECIES AND GRADE (BASE DESIGN VALUE) 1. 6x BEAMS AND HEADERS. "DOUG FIR-LARCH" NO. 1 (Fb=1350 PSI, Fv=170 PSI) 2. 2x TO 4x JOISTS, PURLINS AND HEADERS. "DOUG FIR-LARCH" NO. 2 (Fb=900 PSI, Fv=180 PSI) OR "HEM-FIR" NO. 1 (Fb=975 PSI, Fv=150 PSI) 3. 6x POSTS AND COLUMNS. "DOUG FIR-LARCH" NO. 1 (Fc=1000 PSI) 4. EXTERIOR STUDS, INTERIOR BEARING WALLS AND 4x COLUMNS. "DOUG FIR-LARCH" NO. 2 (Fb= 900 PSI, Fc= 1350 PSI) OR "HEM-FIR" NO. 1 (Fb=975 PSI, Fc=1350 PSI). 5. INTERIOR NON-BEARING STUD WALLS. "DOUG FIR-LARCH" NO. 2 (Fb=900 PSI. Fc=1350 PSI) OR "HEM-FIR" NO. 1 (Fb=975 PSI, Fc=1350 PSI) STRUCTURAL COMPOSITE LUMBER (SCL): SHALL BE MANUFACTURED BY WEYERHOUSER, OR PRE-APPROVED EQUAL IN ACCORDANCE WITH APPROVED SHOP AND INSTALLATION DRAWINGS CONFORMING TO A CURRENT ICC EVALUATION REPORT. LENGTH (IN)TRACKER** COLOR CODED NAILS 8d 10d 16d 20d .131 .148 .162 .192 2-1/2 3 3-1/2 4 BLUE PURPLE ORANGE ----- TRACKER** COLOR CODED NAILS 2-1/2 2-1/2 1-7/8* 3 3 EQUIVALENT SPACING (IN) LENGTH (IN)DIA. (IN)FASTENER TYPE SBX: DOT SODIUM BORATE FIR: DOUG-FIR OR HEM-FIR ACQ: ALKALINE COPPER QUAT SP: SOUTHERN PINE CBA & CA: COPPER AZOLE 2. CONNECTORS: JOIST HANGERS, STRAPS, FRAMING CONNECTORS, COLUMN CAPS AND BASES, ETC. FASTENERS: MACHINE BOLTS, ANCHOR BOLTS AND LAG SCREWS WITH ASSOCIATED PLATE WASHERS AND NUTS. NAILS, SPIKES, WOOD SCREWS, ETC. 3. G60, G90 & G185 PER ASTM A653 FOR COLD-FORMED STEEL CONNECTORS. BATCH/POST HOT-DIP GALVANIZED PER ASTM A123 FOR CONNECTORS. HOT-DIP GALVANIZED PER ASTM A153 FOR FASTENERS OR MECHANICALLY GALVANIZED FASTENERS PER ASTM B695, CLASS 55 OR GREATER. 1. CCA: CHROMATED COPPER ARSENATE NOT PERMITTED 2x, 4x, 6x (FIR), OR GLULAM (SP) 2x, & 4x (FIR) 2x, & 4x (CEDAR) SBX GALV (G60) ACQ, CBA, CA ACQ, CBA, CA NONE 6x (FIR), OR GLULAM (SP) 6x OR GLULAM (CEDAR) NONE GALV (G90) GALV (G185) GALV (G90) ACQ, CBA, CA GALV (G185) GALV (G185)EXPOSUREWETCONNECTORS & FASTENERS (2)(3) PRESERVATIVE TREATMENT (1) SPECIFIED MATERIAL FRAMING, DECKING BEAMS & COLUMNS FOUNDATION SILL PLATES, TOP PLATES & LEDGERS ON CONCRETE OR MASONRY WALLS (4)DRYAPPLICATION 06/10/2021 34321 35th Ave SWFederal Way, Wa 98023253-678-8578Parcel # - 3089000088Daniel MaganaPrinted On: 5/15/2021 09:22:13 Sheet: Elevation Job #: 21-0078Disclaimers:---These plans are exclusive property of Elevation (ELE) and may not be sold to any person or businesswithout expressed written consent of ELE. These plans are for one (1) time use only for ELE's customer -Magana, Daniel and to be built on the customer's site at 34321 35th Ave SW in Federal Way, Wa 98023.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation. Written permission must be obtained and granted prior to anyuse and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.biz I II II I II II Layout Sheet # 6 of 9 Foundation Plan S1.1 WH T Tub/ShowerW01 2020 XO ExistingExistingW02 8040 XOX ExistingW03 5040 XO Egress 3068 50 Bypass H02 2668 H03 2668 40684068 40685'-9"5'-2"28"11'-8"28"3'-7"24"36"7'-5" 4'8'4'7'-6"29 1/4"5'-1 3/4"28" 14"5'30" 36"3'-0 1/2"18" 718 SQ FT 1st Floor Framing Plan - EHD-1007181-S Proposed Scale: 1/4 in = 1 ft BATH #1 CLOSET #1 CLOSET #2 PANTRY BEDROOM #1 CLOSET #3 KITCHEN LIVING ROOM ENTRY LIVING AREA Existing Double 2x10 Beam Proposed 6x6 Post 18"18"12"8'-8"32" CL 9'-2 1/4" CL 9'-3"T.Y.P. Plumbing Drops Proposed Pad for 6x6 Post GARAGE SLAB Existing Slab Foundation Floor Plan - EHD-1007181-S Proposed Scale: 1/4 in = 1 ft 718 SQ FT 1st Floor Shearwall Plan - EHD-1007181-S Proposed Scale: 1/4 in = 1 ft BATH #1 CLOSET #1 CLOSET #2 PANTRY BEDROOM #1 CLOSET #3 KITCHEN LIVING ROOM ENTRY LIVING AREA Roof Framing Plan - EHD-1007181-S Proposed Scale: 1/4 in = 1 ft Existing Ceiling Joist Existing Rafters Proposed 6x6 Post Existing Double 2x10 Beam HOLDOWN LEGEND 1. HDU2 HOLDOWN OR STHD14 SWXX SW1 REFER TO SHEARWALL SCHEDULE ON PAGE S5.4 ALL EXTERIOR WALLS SHALL BE SW1 UNLESS NOTED OTHERWISE FOUNDATION NOTES: 1. DO NOT SCALE DRAWINGS, REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 2. BOTTOM OF EXTERIOR FOOTINGS SHALL BE MINIMMUM 12" BELOW GRADE 3. 4" CONCRETE SLAB OVER 6MIL VAPOR BARRIER ON 6" PF GRAVEL OR CRUSHED ROCK OVER FIRM UNDISTURBED SOIL OR ENGINEERED COMPACTED BACK-FILL. REINFORCE WITH 6 x 6 W1.4 x W1.4 WWF 4. ALL WOOD IN CONTACT WITH CONCRETE SHOULD BE PRESSURE TREATED WOOD. 5. REFER TO GENERAL STRUCTURAL NOTES PAGE ON S0.0 FOR ADDITIONAL REQUIREMENTS. FOUNDATION SCHEDULE F-1: 2' DIA x 10'' W/ 3#4 BARS E.W. (or square) ROOF FRAMING NOTES: 1. DO NOT SCALE DRAWINGS, REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 2. PRE-MANUFACTURED ROOF TRUSS DESIGN IS TO BE PROVIDED BY MANUFACTURER. SEE STRUCTURAL NOTES ON S0.0 FOR REQUIREMENTS. 3. ROOF SHEATHING SHALL BE 15/32" A.P.A. RATED PANELS. (EXPOSURE 1, SPAN RATING 32/16). NAIL SHEATHING AT ALL FRAMED PANEL EDGES WITH 8d AT 6" O.C. AND TO ALL INTERMEDIATE FRAMING AT 12" O.C. NAILS SHALL BE LOCATED AT LEAST 3/8" FROM THE EDGES OF PANELS. 4. HEADERS OVER LOAD BEARING DOORS AND WINDOW OPENINGS SHALL BE MINIMUM 4x10 U.N.O. 5. PROVIDE (2) STUDS MINIMUM AT EACH END OF ALL BEAMS U.N.O. ON PLANS. BEAR BEAM FULLY ON BUILT UP COLUMN AND PROVIDE POSITIVE CONNECTION BY EITHER A35 OR LTP4 CLIPS ON EACH SIDE OF BEAM 6. REFER TO GENERAL STRUCTURAL NOTE PAGE ON S0.0 FOR ADDITIONAL REQUIREMENTS 7. PANELS SHALL NOT BE LESS THAN 4' X 8' EXCEPT AT BOUNDARIES AND CHANGES IN FRAMING WHERE MINIMUM PANEL DIMENSION SHALL BE 24". 1 1 1 1 1 1 F-1 06/10/2021 34321 35th Ave SWFederal Way, Wa 98023253-678-8578Parcel # - 3089000088Daniel MaganaPrinted On: 5/15/2021 09:22:13 Sheet: Elevation Job #: 21-0078Disclaimers:---These plans are exclusive property of Elevation (ELE) and may not be sold to any person or businesswithout expressed written consent of ELE. These plans are for one (1) time use only for ELE's customer -Magana, Daniel and to be built on the customer's site at 34321 35th Ave SW in Federal Way, Wa 98023.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation. Written permission must be obtained and granted prior to anyuse and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizLayout Sheet # 7 of 9 Structural Details S4.1 06/10/2021 34321 35th Ave SWFederal Way, Wa 98023253-678-8578Parcel # - 3089000088Daniel MaganaPrinted On: 5/15/2021 09:22:13 Sheet: Elevation Job #: 21-0078Disclaimers:---These plans are exclusive property of Elevation (ELE) and may not be sold to any person or businesswithout expressed written consent of ELE. These plans are for one (1) time use only for ELE's customer -Magana, Daniel and to be built on the customer's site at 34321 35th Ave SW in Federal Way, Wa 98023.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation. Written permission must be obtained and granted prior to anyuse and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizLayout Sheet # 8 of 9 Structural Details S4.2 06/10/2021