05-105503CITY OF
A. Federal
Mr. Paul Wozniak
Odelia Pacific
208 Westlake Avenue North
Seattle, WA 98109
CITY HALL
33325 8th Avenue South • PO Box 9718
Way Federal Way, WA 98063-9718
(253)835-7000
www.cityoffederalway.com
Re: File #05-105503-00-PC; PREAPPLICATION CONFERENCE SUMMARY
Enchanted Parkway PWSF; 1741 South 3561h Street, Federal Way
Dear Mr. Wozniak:
December 19, 2005
l
Thank you for participating in the preapplication conference with the City of Federal Way's Development
Review Committee (DRC) held November 17, 2005. We hope that the information discussed at that
meeting was helpful in understanding the general requirements for your project as submitted.
This letter summarizes comments given to you at the meeting by the members of the DRC. The members
who reviewed your project and provided comments include staff from the City's Planning and Building
Divisions and Public Works Department, and representatives from Lakehaven Utility District and Federal
Way Fire Department. Some sections of the Federal Way City Code (FWCC) and relevant information
handouts are enclosed with this letter. Please be advised, this letter does not represent all applicable
codes. In preparing your formal application, please refer to the complete FWCC and other relevant codes
for all additional requirements that may apply to your project.
The key contact for your project is Associate Planner Jeff O. Johnson (253-835-2626, or
jeff.johnsonCoDeityoffederalway.com). For specific technical questions about your project, please contact
the appropriate DRC representative as listed below. Otherwise, any general questions about the
preapplication and permitting process can be referred to your key contact.
PROJECT DESCRIPTION
Replace six antennae with nine antennae on and existing lattice tower; equipment enclosures to be located
in an existing compound on an existing concrete pad.
MAJOR ISSUES
No major issues were identified in connection with this project.
DEPARTMENT COMMENTS
Outlined below are the comments made by the representatives of each department present at the
preapplication conference. Each section should be read thoroughly. If you have questions please contact
the representative listed for that section.
PLANNING DIVISION (Jeff O. Johnson, 253-835-2626, 'eff.'ohnson ci offederalwa .com
A. Land Use Review Process
Use Process I— Applications for improvements or additions to existing PWSF that are not subject to
SEPA review are processed consistent with FWCC Chapter 22, Article IV.B, "Process I Review —
File #05-105503-00-PC Doc. 1 D. 33880
Mr. Paul Wozniak
Page 2
December 19, 2005
Director's Approval." This application will be processed accordingly, and for compliance with the
standards of FWCC contained in Chapter 22, Article XI, "District Regulations for the Community
Business Zone (BC)" and applicable sections of Article IV, "Nonconformance"; Article XHI,
"Supplementary District Regulations"; Article XIV, "Critical Areas"; Article XV, "Parking"; Article
XVI, "Improvements"; Article XVII, "Landscaping"; and Article XIX, "Community Design
Guidelines." The administrative review process begins at the time an application is received. At the
conclusion of the staff review, recommendations are forwarded to the Director of Community
Development Services, who then issues a written decision. Neither public notice nor public hearing
are required.
Submittal Requirements — An application submittal must meet minimum requirements, listed in the
enclosed form, "PWSF Development Requirements."
Plan/Drawing Requirements — Drawings must meet minimum standards, listed in the enclosed
"PWSF Development Requirements" under "General Plan Standards."
PWSF Fee for Use Process I— Fees associated with this application total $64. A check for the full
amount of the fees must accompany the application at the time of submittal. Additional time may be
billed later at $59.00 per hour if needed to complete the review. Fees are subject to change annually.
B. Nonconformance
Nonconformance Threshold — This project does not appear to meet any of the conditions that would
trigger FWCC nonconformance requirements. Nonconformance status will be verified at the time of
formal review.
C. Critical Areas
Critical Areas — Based maps and inventories available at the time of my preapplication analysis,
there does not appear to be any critical areas on or around the subject property. Critical area
conditions will be verified during the formal development review process.
D. State Environmental Policy Act (SEPA)
SEPA Review — PWSFs are exempt from SEPA review only if they are not in a critical area and meet
one of three criteria outlined in Washington Administrative Code (WAC) 197-11-800. Your project
meets two of the necessary WAC criteria and, therefore, is exempt from environmental review under
SEPA.
E. District Regulations
Permitted Uses — PWSFs are permitted in the BC Zone, subject to approval of the Director,
consistent with FWCC Chapter 22, Articles Il, V, and XI. This proposal is located in a Community
Business (BC) zone. The height limit is 148 feet and the proposed structure height is 127 feet.
Facility Collocation — The proposal is for a permanent collocation on an existing PWSF. City code
requires that PWSF providers cooperate with other providers in collocating facilities. Please submit a
collocation agreement with your formal application.
File #05-105503-00-PC Doc. I.D. 33890
Mr. Paul Wozniak
Page 3
December 19, 2005
F. Development Standards
Cumulative Impacts — City code requires that the formal review consider the cumulative visual
effects of mounting a PWSF on an existing structure. Please submit photos of the existing facility
and photo simulations of the proposed facility. Please include the antennae, the tower or structure
supporting the antennae, equipment enclosures, the ground compound or building, landscaping, and
screening.
Preferred Antennae Location — Pursuant to FWCC Section 22-966, PWSF antennae sites must be
considered in priority order. The location you have proposed (an existing tower) is second in order
of the preference stipulated by. City code. Provide analysis and documentation in support of rejecting
the higher priority sites.
Preferred Equipment Enclosure Location — Pursuant to FWCC Section 22-967, PWSF equipment
enclosure sites must be considered in priority order. The location you have proposed (above ground
on an existing pad) is third in order of preference, as stipulated by City code. Provide analysis and
documentation in support of rejecting the higher priority sites.
Equipment Enclosure Standards — As proposed, the equipment enclosures is not consistent with
FWCC Section 22-967(5), which stipulates equipment enclosure configurations and their
corresponding permitted locations. To comply, the equipment enclosure must be no taller than six
feet, or the equipment enclosure must be located in an enclosed building, or the equipment enclosure
must be located underground.
PWSF Outside Public Right -of -Way — As proposed, this facility is not consistent with FWCC
Section 22-967(1), "Development Standards," which stipulates equipment enclosure configurations
and their corresponding permitted locations. To comply, the antennae must meet the definition of
microcell, or the equipment enclosure must be no taller than six feet, or the equipment enclosure
must be located in an enclosed building, or the equipment enclosure must be located underground.
G. Landscape
Screening — In order to minimize visibility of the facility, the PWSF must be screened to the greatest
extent possible, as stipulated in FWCC Section 22-967(4).
PUBLIC WORKS DEVELOPMENT SERVICES DIVISION
No comments on the project preapplication.
PUBLIC WORKS TRAFFIC DIVISION
No comments on project preapplication.
BUILDING DIVISION (Scott Sproul, 253-835-2633, scott.sproul@cityoffederalway.com)
No comment at this time.
File #05-105503-00-PC Doc. LD. 33880
Mr. Paul Wozniak
Page 4
December 19, 2005
LAKEHAVEN UTILITY DISTRICT
No comments on the project preapplication.
FEDERAL WAY FIRE DEPARTMENT
No comments on the project preapplication.
CLOSING
This letter reflects the information provided at the preapplication meeting and is intended to assist you in
preparing plans and materials for formal application. We hope you found the comments useful to your
project. We have made every effort to identify major issues to eliminate surprises during the City's
review of the formal application. The completion of the preapplication process in the content of this letter
does not vest any future project application. Comments in this letter are only valid for one year as per
FWCC Section 22-1657.
As you know, this is a preliminary review only and does not take the place of the full review that will
follow submission of a formal application. Comments provided in this letter are based on preapplication
materials submitted.
Modifications and revisions to the project as presented for this preapplication may influence and modify
information regarding development requirements outlined above. In addition to this preapplication letter,
please examine the complete FWCC and other relevant codes carefully. Requirements that are found in
the codes that are not addressed in this letter are still required for your project.
If you have questions about an individual comment, please contact the appropriate department
representative noted above. Any general questions can be directed towards the key project contact, Jeff O.
Johnson (253-835-2626 orLeff johnson@cityoffedeialway.com). We look forward to working with you.
Since ,
Jeff O. Johnson
Associate Planner
enc: Preapplication Meeting Sign -Up Sheet
Master Land Use Application
"PWSF Development Requirements" Handout
FWCC Section 22-966, "Personal Wireless Service Facilities"
c: Kari Cimmer, Lead Development Specialist
File N05-105503-00-PC
Doc. J.D. 33880
VICINITY MAP
$ 8 3481h 91
s up; m
sW k.
SITE LOCATION
,IF
.. m
S 3561h SL
G2
411 S 31%0, 61
9V
s �pl,h 536,�wN
R`
Y t
I'ar
gLj
WIRELESS
ENCHANTED PKWY
1741 S 356th ST
FEDERAL WAY, WA 98003
SC1808 (WA109 )
GENERAL LOCATION MAP
se is+.
S
it 7 •IiIOY�
Na F�dvAt Y7�
,'�d+`:'. �4•t9el',17e.7„ #.� I,ii ]►NI II 's if,c! '-` _ .
i , SY� ion, I�,npu -0, " .•�� k+>�
TFSi.'iYi{a
rift;
Ste 1 ,ems •••�
F.ryp L E 1 D$I
Nr
YF.
e.•oon ldd9llB3
DRIVING DIRECTIONS
STARTING FROM 16221 NE 72nd WAY, REDMOND, TURN RIGHT ON 164th AVENUE NE. TURN RIGHT ON BEAR CREEK PKY. TURN LEFT ON LEARY WAY NE, TAKE
RAMP ONTO WA-520 WEST TOWARDS SEATTLE. TAKE THE 1405 SOUTH EXIT TOWARDS RENTON,1-405 SOUTH BECOMES WA518 WEST. TAKE THE 1-5 SOUTH
EXIT TOWARDS PORTLAND. TAKE EXIT #142B ONTO WA-18 WEST TOWARDS PUYALLUP, TURN LEFT ON ENCHANTED PKWY S. TURN LEFT ON S 356th ST.
ARRIVE AT 1741 S 356th ST ON THE RIGHT.
APPROVAUSIGN OFF OF CONSTRUCTION DRAWINGS
CONSULTANT GROUP SIGN OFF
DATE
SIGNATURE
CINGULAR SIGN OFF
DATE
SIGNATURE
CONSTRUCTION COORDINATOR
COMPLIANCE
LANDLORD'S REPRESENTATIVE
CONSTRUCTION MANAGER
PROJECT MANAGER
DEPLOYMENT MANAGER
SITEACQUISITION
E911 ENGINEER
Y N
INITIAL:
ZONING
UMTS ENGINEER
INTERCONNECT
OPERATIONS
RF ENGINEER
REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO
EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED
RF ENGINEER MANAGER
MAN
SITE AQUISITION MANAGER
PROJECT INFORMATION
APPLICANT:
PROJECT CONSULTANTS-.
NEW CINGULAR WIRELESS LLC
LUCENT TECHNOLOGIES
16221 NE 72nd WAY
10735 WILLOWS ROAD, SUITE 200
REDMOND TOWN CENTER, BUILDING 1r33
REDMOND, WA 9W52
P.O. BOX 97061
CONTACT: NORRIS BACHO, MUP, PHC
REDMOND, WA 98052
PHONE: (206) 227-4443
PROJECT ENGINEER:
PROPERTY OWNER:
CORNERSTONE ENGINEERING
INC RL TRUCKING
14201 NE 200th ST SUITE 200
1741 S 356th STREET
WOODINVILLE, WA 9W72
FEDERAL WAY, WA96003
OFFICE: (425) 487-1732
CONTACT: RUSS LLOYD
CONTACT: MARK OLSON, P.E.
PHONE: (206) 661-6967
CODE INFORMATION.
ZONING CLASSIFICATION:
COMMERCIAL
BUILDING CODE:
2003 IBC
CONSTRUCTION TYPE:
TELECOMMUNICATIONS
OCCUPANCY:
UNOCCUPIED
JURISDICTION:
CITY OF FEDERAL WAY
PROPOSED BUILDING USE:
UNMANNED TELECOM FACILITY
SITE LOCATION: (BASED ON NAD 831 PARCEL NUMBER S
LATITUDE:
4r 16' 5r N
2821049178
LONGITUDE:
122' 16' 39.7" W
TOP OF STRUCTURE AGL•
148.00'
AREA OF PARCEL:
BASE OF STRUCTURE:
0.0' (ASSUMED)
1.31 ACRES
57,055 S.F.
PROJECT AREA
208 S.F. EQUIPMENT AREA
NEW IMPERVIOUS AREA:
2,120 t S.F. ENTIRE COMPOUND
0 S.F.
GENERAL INFORMATION:
1. PARKING REQUIREMENTS ARE UNCHANGED,
2. TRAFFIC IS UNAFFECTED.
3. SIGNAGE IS PROPOSED.
4. NO ADDITIONAL IMPERVIOUS AREA IS PROPOSED
PROJECT LTESCRIPTION;
THIS PROPOSAL IS FOR THE MODIFICATION OF AN EXISTING UNMANNED
TELECOMMUNICATIONS FACILITY, CONSISTING OF REMOVAL/REPLACING OF (E)
ANTENNAS WITH NEW AND THE ADDITION OF NEW EQUIPMENT CABINETS WITHIN
EXISTING LEASE SPACE.
PROPRIETARY INFORMATION
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION
DOCUMENTS IS PROPRIETARY By NATURE. ANY USE OR
DISCLOSURE OTHER THAN THAT WHICH RELATES TO CINGULAR
WIRELESS, LLC. SERVICES IS STRICTLY PROHIBITED.
PACIFIC CORPORATION
208 WESTLAKE AVENUE NORTH
SEATTLE, WA98109
206.4903800
DRAWING INDEX
DWG.
NO.
DESCRIPTION
T-1
TITLE SHEET
GA
GENERAL NOTES
A 1
SITE PLAN
A-2
COMPOUND PLAN
A-3
EXTERIOR ELEVATION(S)
A-4
EQUIPMENTSPECS
A 5
CONSTRUCTION DETAILS
A-6
RADIO PLAN
A-7
ANTENNA SWEEP TEST & COAX MARKING
E-1
ELECTRICAL DETAILS
E 2
GROUNDING DETAILS
E3
PANEL SCHEDULE & ONE -LINE DIAGRAM
LEGAL DESCRIPTION
282104 178 BEG NXN N LN SW 114 OF NW 114 & ELY MGN ST
H WY 5D TH E 275 FT TO PT A TH E 201.31 FT TH S 00-09-00 W
255 FT TH S 89-36-00 W 201 FT TO PT S 00-24-00 E FIR PT A TH N
00-24-00 W 225 FT TO PT 30 FT S FIR PT A TH S 89-36-00 W TO
ELY MGN ST HWY TH NLY ALG SO ELY MGN TO TPOB - LESS
POR AS PER SC 96.2-08664-9KNT
��ILOING DEFT.
14201 NE 200th ST, SUITE 200
WOODINVILLE, WA 98072
PH:425.487.1732 FAX:425.487.1734
:START DATE: 09rmms
DRAWN BY: JRF
CHECKED BY: MWO
1■AJLt
W.
w
it
I
t�tBjOFL1�
SITE
SC1808 (WA109)
ENCHANTED PKWY
1741 S 356th ST
FEDERAL WAY, WA98W3
SHEET TITLE
TITLE SHEET
SHEET NUMBER
T-1
y
GENERAL NOTES -
I DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS SET OF DOCUMENTS
IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSED ONLY, UNLESS NOTED OTHERWISE THE
GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT,
LABOR AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED IN THE
DRAWINGS AND OWNER'S PROJECT MANUAL
2. THE CONTRACTOR IS RESPONSIBLE FOR ALL DIMENSIONS AND STANDARDIZED DETAILS THAT REQUIRE
MODIFICATIONS DUE TO ACTUAL FIELD CONDITIONS AND REQUIREMENTS MUST BE SUBMITTED TO AND
APPROVED BY, CINGULAR REPRESENTATIVE PRIOR TO START OF WORK
3. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE
THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS SHALL VISIT
THE CONSTRUCTION SITE WITH THE CONSTRUCTIOWCONTRACTDOCUMENTS TOVERIFY FIELD
CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO
PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO
THE ATTENTION OF THE ARCHITECTIENGWEER VERBALLY AND IN WRITING.
4 THE ARCHITECTSIENGINEER HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND
CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK CONTRACTORS BODING THE JOB ARE
NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN TIE DRAWINGS AND OR
SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND
IMPROVEMENTSIN ACCORDANCE WITH THE' INTENT OF THESEDOCUMENTS:THESIDDERSHALLBEAR
RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHTTECTIENGINEEROF ANY CONFLICTS, ERROR OR
OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S PROPOSAL IN THE EVENT OFDISCREPANCIESTHE
CONTRACTOR SHALL PRICE THE MORE EXTENSIVE WORK; UNLESS DUCTED OTHERWISE
THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN ATIHORRATION TO PROCEED WITH CONSTRUCTION
PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION
DRAWINGSICONTRACT DOCUMENTS.
6. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT
DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS,
METHODS, TECHNIQUES, SEQUENCES, SAFETY, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF
THE WORK UNDER THE CONTRACT.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO
MANUFACTURER'SNENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR
ORDINANCES TAKE PRECEDENCE.
8. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE
WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES
AND COMPLY WITH ALL LAWS, ORDINANCES. RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC
AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCALAND STATE JURISDICTIONAL
CODES BEARING ON THE PERFORMANCE OF THE WORK
9: GENERAL'CONTRACTORSHALL'.PROVIDE;XrTHtPROJECT'SRE AFULL-SET'OF CONSTRUCTION
DOCUMENTS UPDATED WITH THE LATEST REVISIONS INVOLVED WITH THE PROJECT. THIS SET ISAVALID
CONTRACT DOCUMENT ONLY IF THE TITLE SHEET IS STAMPED IN RED INK"FOR CONSTRUCTION" AND EACH
SUCCESSIVE SHEET BEARS THE ENGINEERS SIGNED WET STAMP.
10. ALL MATERIAL FURNISHED UNDER THIS CONTRACT SHALL BE NEW, UNLESS OTHERWISE NOTED. ALL WORK
SHALL BE GUARANTEED AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP. THE CONTRACTOR SHALL
REPAIR OR REPLACE AT HIS EXPENSE ALL WORK THAT MAY DEVELOP DEFECTS IN MATERIALS OR
WORKMANSHIP WITHIN SAID PERIOD OF TIME OR FOR ONE YEAR AFTER THE FINAL ACCEPTANCE OF THE
ENTIRE PROJECT, WHICHEVER IS GREATER
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAILY CLEAN UP OF ALL TRADES AND REMOVE ALL DEBRIS
FROM THE CONSTRUCTION SITE. AT THE COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL
THOROUGHLY CLEAN N THE BUILDING, SITE, AND ANY OTHER SURROUNDNG AREAS TO A BETTER THAN NEW
CONDITION
12• THE CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING
CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, ETC. ACCORDING TO APPLICABLE CODES,
STANDARDS, AND GOOD CONSTRUCTION PRACTICES.
13. THE CONTRACTOR SHALL MEET ALL OSHA REQUIREMENTS FOR ALL INSTALLATIONS.
14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES TO THE DOTING CONSTRUCTION AND
REPAIR ALL DAMAGES TO BETTER THAN NEW CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE
CONSULTANT OF ANY DAMAGE TO THE BUILDING SITE OR ANY ADJACENT STRUCTURES AROUND THE
PROJECT. THE ATE REPRESENTATIVE SHALL BE SOLE AND FINAL JUDGE AS TO THE QUALITY OF THE
REPAIRED CONSTRUCTION. ANY ADDITIONAL MODIFICATIONS WHICH MUST BE MADE SHALL BE MADE AT
THE CONTRACTORS EXPENSE.
15. WHERE NEW PAVING, CONCRETE SIDEWALKS OR PATHS MEET EXISTING CONSTRUCTION, THE
CONTRACTOR SHALL MATCH THE EXISTING PITCH, GRADE, AND ELEVATION SO THE ENTIRE STRUCTURE
SHALL HAVE A SMOOTH TRANSITION.
16. THE CONTRACTOR SHALL MODIFY THE EXISTING FLOORS, WALL, CEILING, OR OTHER CONSTRUCTION AS
REQUIRED TO GAN ACCESS TO AREAS FOR ALL MECHANICAL, PLUMBING. ELECTRICAL, OR STRUCTURAL
MODIFICATIONS. WHERE THE EXISTING CONSTRUCTION DOORS, PARTITIONS. CEILING, ETC-, ARE TO BE
REMOVED, MODIFIED, OR REARRANGED OR WHERE THE EXPOSED OR HIDDEN MECHANICAL, ELECTRICAL,
SYSTEMS ARE ADDED OR MODIFIED, THE GENERA_ CONTRACTOR SHALL REPAIR, PATCH AND MATCH ALL
EXISTING CONSTRUCTION AND FINISHES OF ALL FLOORS WALLS AND CEILINGS. WHERE CONCRETE
MASONRY CONSTRUCTION IS MODIFIED, THE CONTRACTOR SHALL TOOTH INALL NEW CONSTRUCTION TO
MATCH THE EXISTING BOND. WHERE CONCRETE CONSTRUCTION IS MODIFIED, THE CONTRACTOR SHALL
VERIFY THE EXACT DETAILS TO BE USED FOR CONSTRUCTION. ALL WORK SHALL BE COVERED UNDER THE
GENERAL CONTRACT.
17 TOWER FOUNDATION STRUCTURAL STEEL TO BE GROUNDED PRIOR TO CONCRETE POUR TOWER
FOUNDATION STRUCTURAL STEEL TO BE CONNECTED TO PERMANENT GROUND ROD PRIOR TO TOWER
ERECTION. TOWER GROUND MUST BE MAINTAINED AT Al TIMES.
GENERAL OTES CONTINUED:
18. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR APPLYING FOR COMMERCIAL POWER
- IMMLDIATELY UPON AWARD OF CONTRACT THE GENERAL CONTRACTOR IS REQUIRED TO KEEP ALL
DOCUMENTATION ACKNOWLEDGING APPLICATION FOR POWER WITH THE POWER COMPANY.
19. THE GENERAL CONTRACTOR SHALL OBTAIN WRITTEN CONFIRMATION OF THE EXPECTED DATE OF
COMPLETION OF THE POWER CONNECTION FROM THE POWER COMPANY.
20. IF THE POWER COMPANY IS UNABLE TO PROVIDE THE POWER CONNECTION BY CINGULAWS REQUIRED
DATE, THE GENERAL CONTRACTOR SHALL PROVIDE AND MAINTAIN ATEMPORARY GENERATOR UNTL THE
POWER COMPANY CONNECTION IS COMPLETED- CASTS ASSOCIATED WITH THE TEMPORARY GENERATOR
TO BE APPROVED BY THE CINGULAR REPRESENTATIVE.
21 IF CONTRACTOR OR SUBCONTRACTOR FIND ITNECESSARY TO DEVIATE FROM ORIGINAL APPROVED PLANS,
THEN IT IS THE CONTRACTOR'S AND THE SUBCONTRACTOR'S RESPONSIBILITY TO PROVIDE THE
CONSULTANT WITH COPIES OF THE PROPOSED CHANGES FOR HIS APPROVAL BEFORE PROCEEDING WITH
THE WORK. IN ADDITION THE CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR
PROCURING ALL NECESSARY APPROVALS FROM THE BUIUNNGAUTHORIiIES FOR THE PROPOSED
CHANGES BEFORE PROCEEDING WITH THE WORK THE CONTRACTOR AND SUBCONTRACTORS SHALL BE
RESPONSIBLE FOR PROCURING ALL NECESSARY INSPECTIONS AND APPROVALS FROM BUILDING
AUTHORITIES DURING THE EXECUTION OF THE WORK.
22. MNTTRACTORTOPROVIDE APORTABLE FIRE EKnKGUISHERWITHIM ARATINGOFNOTLESST2"AOR-
2-A1DOC WITHIN 7S PEEP TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION.
23. THE CONTRACTOR SHALL PERFORM WORK DURING OWNERS PREFERRED HOURS TO AVOID DISTURBING
NORMAL BUSINESS.
24. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH UL LISTED OR FIRE MARSHAL APPROVED
MATERIALS AS APPLICABLE TO THIS FACILITY AND OR PROJECT SITE
25. CONTRACTOR SHALL BE RESPONSIBLE FOR UTILITY LOCATES, SCHEDULING, COORDINATING SPECIAL AND
BUILDING DEPARTMENT INSPECTIONS.
26. fANTRACTORSHALL BE RESPONSIBLE FOR CONTACTING AND UTE EM ORIGINAL ROOF94G CONTRACTOR
AS REQUIRED TO MAINTAIN ANY EXISTING ROOFING WARRANTY.
27. ROUTING OF ALL CONDUITS, CABLES, CABLE TRAYS ETC ARE INDICATED AS PROPOSED LOCATION ONLY.
CONFIRM THE E7LACT LOCATION AND ROUTING WITH THE ON SITE CNGULARCONSTRUCTION MANAGER
PRIOR TO STARTING WORK
SITEWORK NOTES:
1- ALL SITE WORK SHALL BE AS INDICATED ON THE DRAWINGS AND STIPULATED IN THE SPECIFICATION
PROJECT SUMMARY-
2. RUBBISH; STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL -BE REMOVED FROM THE SITE AND
DISPOSED OF LEGALLY.
3, THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE PCS EQUIPMENT,
TOWER AREAS, AND ADJACENT BUILDINGS.
4. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZENGROUND- FROZEN MATERIALS, SNOW
OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT.
5. THE SUBGRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO THE
CRUSHED STONE APPLICATION.
6- ALL EXLSTNG ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES WHERE ENCOUNTERED IN THE
WORK. SHALL BE PRDTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER OF THE
WORK, %HALL BE RELOCATED AS DIRECTED BY ENGINEERS. EXTREME CAUTION DL IOULDBE USED By THE
CONTRACTOR WHEN FXGAVATING OR PIER DRILLING AROUND OR NEAT UiI TfIES. CONTRACTOR SHALL
PROVIDE SAFETY TRAINING FOR THE WORKING CREW.
7° ALL EXISTING INACTIVE SEINER, WATER GAS. ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE
EXECUTION OF THE WORK, SHALL BE REMOVED AND SHALL BE GAPED, PLUGGED OR OTHERWISE
DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO
THE APPROVAL OF ENGINEERING.
B. THE AREAS OF THE CUSTOMER'S PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE
BUILDING. DRIVEWAY OR CRUSHED STONE, SHALL BE GRADED TO A UNIFORM SLOPE, FERTILIZED, SEEDED,
AND COVERED WITH MULCH AS SPECIFIED IN THE SPECIFICATION LANDSCAPE WORK
CONCRETE NOTES:
1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318 AND THE SPECIFICATION
CAST-N•PLACE CONCRETE
2 ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AT 28 DAYS UNLESS NOTED
OTHERWISE.
3 REINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE60, DEFORMED UNLESS NOTED OTHERWISE
WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185 WELDED STEEL WIRE FABRIC UNLESS NOTED
OTHERWISE. SPLICES CLASS'S" AND ALL HOOKS SHALL BE STANDARD UNO
4 THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS
SHOWN OTHERWISE ON DRAWINGS: CONCRETE CAST AGAINST EARTH..... 31N.
CONCRETE EXPOSED TO EARTH OR WEATHER:
#6 AND LARGER ...................2 IN
#5 AND SMALLER 8 WWF ..- ...1121N.
ABBREVIATIONS:
AFF
ABOVE FINISHED FLOOR
JT
JOINT
APO
ABOVE FINISHED GRADE
LAM
LAMINATED
AFS
ABOVE FINISHED SLAB
LF
LINEAL FOOT
ALUM
ALUMINUM
MANUF
MANUFACTURER
AB
ANCHOR BOLT
MAX
MAXIMUM
L
ANGLE
MECH
MECHANICAL
ARCH
ARCHITECTURAL
MH
MANHOLE
BTS
BASE TRANSMISSION SYSTEM
MM
MILLIMETER
BLDG
BUILDING
MIN
MINIMUM
BM
BEAM
MISC
MISCELLANEOUS
BOT
BOTTOM
MPH
MILES PER HOUR
B.O.
BOTTOM OF
MTL
METAL
BOO
BOTTOM OF CONCRETE
NIC
NOT IN CONTRACT
BOB
BOTTOM OF STEEL
NOM
NOMINAL
CJ
CONTROL JOINT
NTS
NOTTOSCALE
CENTERLINE
OC
ON CENTER
CLG
CEILING
OD
OUTSIDE DIAMETER
CLR
CLEAR
OH
OVERHEAD
CMU
CONCRETE MASONRY UNIT
OPNG
OPENING
COL
COLUMN
OPP
OPPOSITE
CONC
CONCRETE
PCs
PERSONAL COMMUNICATION SYSTEM
CONST
CONSTRUCTION
It
PLATE
UOUS
CL�1
PR
PAIR
CTRIT
PSI
POUNDS PER SQUARE INCH
DIA /0
DIAMETER
PSF
POUNDS PER SQUARE FOOT
DTL
DETAIL
PT
PRESSURE TREATED
(
RA)
RADIUS
EA
�
RD
ROOFDRAIN
EJ
EXPANSION JOINT
REINF
REINFORCEDIRENFORCING
ELEC
ELECTRICIEIECTRICAL
REOD
REQUIRED
EL
ELEVATION
RM
ROOM
EQ
EQUAL
RN
RIGHT OF WAY
EW
EACH WAY
SCHED
SCHEDULE
EXP
EXPANSION
SECT
SECTION
EXT
EXTERIOR
SF
SQUARE FOOT
FD
FLOOR DRAIN
SFM
SIMILAR
FTN
FINISH
SO FT
SQUARE FOOT
FIN FUR
FINISH FLOOR
SS
STAINLESS STEEL
FUR
FLOOR
STD
STANDARD
FTG
FOOTING
STL
STEEL
GA
GAUGE
STRUC
STRUCTURAL
GALV
GALVANIZED
TEMP
TEMPORARY
GYP
GYPSUM
THK
THICK
GB
GYPSUM BOARD
T.O.
TOP OF
HM
HOLLOW METAL
TOS
TOP OF STEEL
HOR
HORIZONTAL
TOO
TOP OF CONCRETE
HR
HOUR
TYP
TYPICAL
HT
HEM
LIND
UNLESS NOTEDOTHERWISE
HVAC
HEATING VENTILATION AIR CONDITIONING
VERT
VERTICAL
INSUL
INSULATION
W/
WITH
NT
INTERIOR
WWM
WELDED WIRE MESH
LEGEND AND SYMBOLS:
CHAINLINK FENCE x x x
CEDAR FENCE ° 0
POWER P P P
TELCO T T T �—
POWERITELCO —TT —TIP — TR — Tm
COAX COAX cows coax —
OVERHEAD POWER OH DR 0H 0H
CENTERLINE
REVISION BUG
DETAIL NUMBER
/ C_l
ELEVATION VIEW BUG Q_
SHEET NUMBER
TOP OF ...
ELEVATION
EL OO —Op
DETAIL NUMBER
DETAIL BUG SHEETNUMBER
SECTION BUG ;
DETAIL NUMBER
SHEET NUMBER
^` • N V
tUILDING DIP-'.
14201 HE 200th ST. SUITE 200
WOODINVILLE, WA 98072
PH:426497A732 FAX-42SA07.1734
START DATE: 0920Y05
DRAWN BY: JRF
CHECKED BY: mwo
REVISIONS I
*MXi4
W.
I F>iPIRES _. 07It5f07 �
SITE
SC1 BOB (WA109)
ENCHANTED PKWY
1741 S 356th ST
FEDERAL WAY, WA 98003
SHEET TITLE
GENERAL NOTES
SHEET NUMBER
1
u
161
NOTE:
NOT A SITE SURVEY
NO ADDITIONAL LANDSCAPING
INCLUDED IN THIS PROJECT
SITE PLAN
22x34 SCALE: I' = W-Q;'
1X17 SCALE: l'-
(E)
BUILDING
S 3-5ft--ST
APN #
2821049172
ADJACENT ZONING
USE: COMMERCIAL
ZONE: COMMERCIAL
\ \ ADJACENTZONING
USE: COMMERCIAL
ZONE: COMMERCIAL
1 '� \ APN #
2821049077
s��I \
1 \
Ile
6
(E)
BUILDING
"A�
APN#
2821049028
DIRT
ROAD
SITEACCESS
C
u ,fir
(E) TREE
(TYP)
(E)
BUILDING
f 7
f--I_i [I p i i I_LLLLLL, J LLLLI-' I I I I LI -1
ITF7[Tii-f-r-T-i-iln-i-T-r,TT7-T-FTTI—Tr
(E)
BUILDING
ADJACENT ZONING
USE: COMMERCIAL
ZONE: COMMERCIAL
APN #
2821049178
GRAVEL
PARKING LOT
-, Ni
i i I,
-AL.ulT
a �j
p-� -4
(E)
RL TPUCVJNG zi
BUILDING
PROPERTY LINE I I I i I L I L I! c
APN #
2621049069
T r i I
(E)
BUILDING
w!
LA.! lj -fl T
PLAN
NORTH
1
09
c
w
WYE- ;,E-@ �. tjT
PH:425AST.1732 FA7L• 42 . 37, 734,
START DATE: O820ID5
DRAWN BY:
CHECKED --BY* mwo
I DATE I mmWPIION jl�Kj
SITE
SC1808 (WA109)
ENCHANTED PKWY
1741 S 356th ST
FEDERAL WAY, WA 98003
SHEET TITLE
N
SITE PLAN
SHEET NUMBER
A-1-
I
(E) WIRELESS CARRIER
(E) CHAINLINK FENCE CONCRETE SLAB
i
(E) CONCRETE SLAB
(E)DUPLEXER
I BACKBOARD
NOKIA
CABINET
t 1 (E) "
\\ II ERICSSON �i Ir PROPOSED
CABINET i j 100 AMP 2P
BREAKER PANEL
li
FOR UMTS
r{ NOKIA
i I it CABINET \ ��
(E) 9'-9"HIGH
-
jl
* ll��'7i y ICE BRIDGE
}
`LIJ
� I I'� ii -•Ij I
z i _ \\ PROPOSED
i v \ (E) ERICSSON NEMA 3R TELCO
f I CABINET ENCLOSURE
.. I • � � _. 'i �l � `
m
i90f
j - (E) CABLE TRAY
I
(E) ai. % - --- - .-......
UMTS ---
CABINET (FUTURE) I
i POWER DOG
I HOUSE
NOKIA °•.- • __..—_ CABINET CABINET
I
(E) 2'-5" HIGH ICE
I BRIDGE (BELOW)
(E) 148' LATTICE TOWER 1� W/ (6) 1-518" COAX
(E) ICE BRIDGE I`
W/ (4) 7/8" COAX
Z
f
ENLARGED COMPOUND PLAN
22x34 SCALE: 3/4" = T-0" I 11x17 SCALE: 3/8" = 1'-0"
I
N \
is ='
4Iw r tt
O
~' — — — •---- —- I
(E) SPRINT COMPOUND �� '� ` - - •-1 1 - ��
p
{ \ I
(E) CINGULAR COMPOUND
e {
(E)ICEBRIDGE _
(E) UTILITY RACK a;
V
• n
7'
(E) OWEST COMPOUND .
(E)
BUILDING
2
+ COMPOUND PLAN
r22X34 SCALE: 114'= T-0"
SCALE: 118" = 1'
(E) 14V LATTICE
TOWER
so
I
PROPERTY LINE
I
I
(E) CHAINLINK FENCE
41
Jl
1
i
a
PLAN
NORTH
1
6UILDIING DEPT.
•• T4201-NE 20Wth ST,-SUITE 200
WOMMALLE, WA 98072
PH.425-4B7.1732 FAX:425.467.1734
START DATE: ovmW
DRAWN BY: JRF
CHECKED BY: tinvo
1 REVISIONS !
SITE
SC1808 (WA109)
ENCHANTED PKWY
1741 S 356th ST
FEDERAL WAY, WA 98003
SHEET TITLE
COMPOUND PLAN
SHEET NUMBER
A-2
COAX LENGTH SCHEDULE
SECTOR
LENGTH
# COAX
DIAMETER
SECTOR
151,
2(E)+6NEW
1-518"
SECTOR B
151'
2 (E) + 6 NEW
1-518"
SECTOR C
151,
2 (E) + 6=E�Wl8"
EXISTING
COAX
DIAMETER
NUMBER
PLACEMENT
FACE OF
1-5l8'
6
TOWER
FACE OF
7/8"
TOWER
ANTENNA PLAN
SECTOR C
SECTOR A
e'�� SECTOR B
GRADE
NEL 0'-0"
EAST ELEVATION
22x34 SCALE: 3132" = I -(r 1107 SCALE: 3184"
n
jk(E).CARRIER ANTENNA RAD-CENTER
EL 14T-7-7-
PROPOSED RAD CENTER OF ANTENNAARRAY _
4;t'EL 12r-W
,anCARRIER ANTENNA RAD-CENTER -- - --
,an
111=7"
�(Ek CARRIER ANTENNA RAD CENTER -- - ---• - •- -
EL 9Y4'
;?, CARRM -
E"EkL 71'�'
TOP OF (Ej LATTICE TOWER S
- - -EL 148'-W
TOP OF PROPOSED ANTENNAARRAY- b
- --- EL 180 ;
PROPOSED ANTENNA
KATHREIN 742-265
(TYP OF 9)
(E) ANTENNA MOUNT
tll
a=
CITY Op AY
142G 1 N
PH:425.487.17W FAX 425A87,VU
START DATE: o9rzoNs
DRAWN BY: .�
CHECKED BY: MM
REVISIONS I
SITE
SC1808 (WA109)
ENCHANTED PKWY
1741 S 3561h ST
FEDERAL WAY, WA 9MM
SHEET TITLE
--]
EAST ELEVATION
SHEET NUMBER
A-3
_ 2'-7 314" _
2 112" _ 2'-2 314" , 2 112"
�I
WELDED C6
ALUMINUM PLINTH
?' (SUPPLIED BY CONTRACTOR)
N
N i ANCHOR BOLT AT
BOTTOM FLANGE
I - (SEE ELEVATION)
1"
11/16" 0 HOLES FOR
PLAN 5/8" D BOLTS
(fYP 4 PLACES)
ml
1.
ISOMETRIC 1112" I±' �11/2-
FILED DRILL 11/16" 0 HOLES FOR
518" 0 CONCRETE EXPANSION ANCHOR
(TYP 4 PLACES)
ELEVATION
UMTS MOUNTING BASE
22x34 SCALE: 3/4"`= 1'Ti` I I I Ixl7 SCALE: 3W= T-4'
NOT USED
22x34 SCALE: NTS Ilxl7 SCALE: NTS
UMTS OUTDOOR DIMENSIONS
MANUFACTURER: LUCENT
HEIGHT: 72"
DEPTH: Ar
WIDTH: 35.4"
CLEARANCE: CABINET REAR 36"
CLEARANCE: CABINET EACH SIDE 35A"
CLEARANCE: CABINET FRONT 29.5"
MAXIMUM CABINET WEIGHT: 790 LBS (359 KG)
2'-1 ly4"
4.33" 26.Tr _
I
o�
(`NV m f0jj}}
N
IN
N
I
UMTS CABINET
ANCHOR FOOTPRINT
u
BACK OF
CABINET
1 UMTS EQUIPMENT SPECIFICATIONS
2244 SCALE: 1'= 1-0' 111x17 SCALE: 112' = 1'-W
- FRONT OF
- -� CABINET
Rf CABLE
ENTRY
w HU0
V I I W Z
on z
is a: m�
w I":
;Ziz I j D Uf
0=
QiV �
zz
�z
Q I C
d
W
J
®
io Q
E
1D 0
NOKIA ULTRASITE
CABINET ----.
0 ULTRASITE FRONT ELEVATION
22x34 SCALE: -r = i,-(r 11 lx17 SCALE: 10' = 1'-0"
NOM OUTDOOR ULTRASITE BTS DIMENSIONS
MANUFACTURER NOIOA
HEIGHT:75A'
DEPTH: 29S -
wIDTH: a9.m mMA7CIMUM CABINET WEIGHT (WRH UNITSkB95 LBS.
30.3"
Y6"
24.4"
1
�5'
10"
`j 10"
5"
10•
PLINTH OF
PLWTH OF
L�y'i t`"
N
CABINET
CABRIE72
C4 N'
,
i
.o
o•
o 0
•o 0•• --'
'
II
IL•o
ULTRASITE MOUNTING PLINTH 2 ULTRASITE EQUIPMENT ISO
322x34 SCALE: 1"= Te 111x17 SCALE: 1l2"= l'-0" I I 22x34 SCALE: 3/4" = l'-0" I IIxITSCALg: 3/8" =1'-0"
u LULU
AY
14201 HE 200th ST, SUITE 200
WOODINVILLE, WA 98072
PR 425.487.1732 FAX 425.487.1734
START DATE: 89MIM
DRAWN BY: xu
+CHECKED BY: MAD
REVISIONS
MTE I OE.SMPTxIN JINMALJ
SITE
SC1808 (WA109)
ENCHANTED PKWY
1741 S 356th ST
FEDERAL WAY. WA98003
SHEET TITLE
EQUIPMENT SPECS
SHEET NUMBER
A-4
ARGUS CABINET
z'-6"
FRONT ELEVATION
POWER CABINET DIMENSIONS. .
MANUFACTURER: ARGUS lE-20
HEIGHT: 84.0"
DEPTH: 30.0"
WIDTH:30.0"
MAXIMUM CABINET WEIGHT (W�10OGLbs
30_00" _
ENCLOSURE
DIMS
i.
0 0.75- HOLE OPENING
• ALL CORNERS -4
W
o PLACES
w
.
[f
o'co
D LL AND IN
m O
I CONCRETE ANCHORS I
NI
(4(HIL"HSLB-hN2125 !
Z
W
(ARGUE PM 033A6B-10)
OR EQUIVALENT
I
T
24.40"�
J
MOUNTING HOLE LOCATION
POWER CABINET EQUIPMENT DETAILS
22x34 SCALE: 1" = F-0' I 11 x17 SCALE: 112' = 1 =0" .
25.00" N
i
f
RIGHT SIDE VIEW
ANTENNA DETAIL
72x34 SCALC: 112" - 1'-0" I1x17 SCALE: 114" = 1'-0"
4 1
NOT USED
22934 SCALE: NTS I 11x17 SCALE: NTS
=r
mI
4
A
BACK SIDE
KATHREIN ANTENNA
742 263
21
�gazavoaral��-
ilS4��Epp}rr� l
�`}�'a•fix•
PH:475.487.1732 FW4+1�:497.1734
START DATE:
DRAWN BY' JRF
CHECKED BY: mwo
"P.'L A
�r W. 0
N p
E%PIRES _ Wf15iY6.-j
SITE
SC1808 (WA1(19)
ENCHANTED PKWY
1741 S 3561h ST
FEDERAL WAY, WA 98003
SHEET TIE
CONSTRUCTIOTLN DETAILS
SHEET NUMBER
A-5
x, cingular-
WMEiESS
1 1lthe New Mech Tdisnolica�b1e,aM4s Eletlrical Tit
RF Englnou hlMt[nD=44&M OW AM
-
(Prini earr�
CkrSular RF: Arawranl.�i.•753-t6U9
RADIO PLAN
22%34 SCALE: NTS 11 W7 SCALE: NTS
CINGULAR WIRELESS
SEATTIE I TAWMA
RF" mrdact below.
Data 12, M
V . i . P Cl2L
X Clrl 9-u-••• • la. MA�keh Seatt e 1 Tacoma Sit. I1r
Dual Band BSU/1900 kk1z Cjms r Id: 2 Sled Name: Enchanted Pkwy
•.q e L3 r a -$ .I, r.' SEctor. t
Oe W
x
X
ERICSSON TMA I •;�
I :
LUCENT
DBDP
X
;= i R
U uc t llMTS
X X
Nokia GSM
:i ular Haaket= scat I Tx ma
l inq.•.!t s e o: sctsas
dusics;d: 3 51ee Name: Endranled Pkwy
DBDP
X
x
ERICSSONTMA01 1'I
I
DaD
X
X
LUCENT MHA
I lllllll
I
I
r I
I �
I
x X
Fri cssan G5M Lucent UMTS Nokia GSM
LiD-e yq
lSaticN: SUttle / TarnDea Sete 7t>r SL7'8
:1 ci ngul� r Grenar Id: 3 Name: Endt.n[rJi Picwy
sdeb— 3
VW DROP
X x
x X
ERICSSON TMA LUCENT A4h1A
i
I
Ei
Erlas n GSM
Lucent UMTS
1
P oU' O�
PH: 425.487.1732 FAX 426.487.1734
53ART DATE: osnaros
DRAWN BY: JRF
CHECKED BY: Mwo
SITE
SC18D8 (WA109)
ENCHANTED PKWY
1741 S 3561h ST
FEDERAL WAY, WA98W3
F7SH�TITLERA
SHEET NUMBER
A-6
SWEEP TEST REQUIREMENTS:
CINGULAR WIRELESS
SEATTLE, WA.
ANTENNA AND TRANSMISSION LINE TEST REQUIREMENTS
REgQEEi] EQUIPMENT.
1 WILTRONIANRITSU SITE MASTER S331AB/C OR EQUIVALENT
1 OPEN, SHORT, LOAD.
1 DIN FEMALE TO N TYPE MALE ADAPTER (LOW LOSS).
1 DIN MALE TO N TYPE MALE ADAPTER -(LOW LOSS).
2 DIN FEMALE TO DIN FEMALE ADAPTER (LOW LOSS).
i PHASE STABLE CABLE.
1 TRUE-RMS MULTI -METER.
FREQUENCIES TO BE USED-_ -
PCS FREQUENCY BAND 185OMHZ-199OMHZ
TRANSMIT FREQUENCY 1930MHZ-lg4OMHZ
RECEIVE FREQUENCY 1850MHZ-186OMHZ
TRANSMISSION LINE AND ANTENNA SYSTEM TEST
(1) INSERTION LOSS/CABLE LOSS
(2) ANTENNAlTRANSMISSION LINE DISTANCE TO FAULT (RL)
(3) ANTENNA SYSTEM RETURN LOSS
(4) ANTENNA SYSTEM WITH DUPLEXERITNWANTENNA RETURN LOSS
(5) TRANSMISSION LINE CONTINUITY TEST
INSERTION LOSS
THIS TEST WILL MEASURE THE CABLE LOSS OF THE TRANSMISSION
LINE AND JUMPERS BETWEEN THE CABINET AND ANTENNA.
TEST FREQUENCIES: F1=1850 F2=1990
1. ENTER THE FREQUENCIES TO BE USED IN Fl AND F2.
2. RE -CALIBRATE TEST EQUIPMENT.
3. CONNECT THE TWO JUMPERS GOING TO THE ANTENNA (BYPASS
TMA) AND THE CABINET (BYPASS DUPLEXER) USING THE DIN (F)
TO DIN {F) CONNECTORS.
4. CONNECT A SHORT AT THE END OF THE LAST JUMPER BEFORE
THE ANTENNA, OF THE LINE UNDER TEST.
5. CONNECT TEST EQUIPMENT TO THE LAST TX JUMPER
(YELLOWIRED) BEFORE THE CABINET, OF THE LINE UNDER TEST.
6. PERFORM MEASUREMENT, THEN DUE STEPS 10 TTtR7LrGH 12.
7.- DISCONNECT TX -JUMPER. THEN CONNECT THE RX JUMPER
(YELLOWIGREEN) TO DIN (F) ADAPTER
8. CONNECT TEST EQUIPMENT TO THE LAST RX JUMPER
(YELLOWIGREEN) BEFORE THE CABINET, OF THE LINE UNDER TEST
9. PERFORM MEASUREMENT, THEN DUE STEP 10 THROUGH 13.
10 ADD THE MAXIMUM PEAK TO THE MINIMUM VALLEY THEN DIVIDE
BY TWO. THIS IS THE CABLE INSERTION LOSS. THIS VALUE SHOULD
NOT BE GREATER THEN 111313.
11. PEAK MAX (MI) + VALLEY MIN (M2)/2= CABLE INSERTION
LOSS.
12. RECORD CALCULATED/MEASURED VALUE ON SWEEP DATA
SHEET, THEN SAVE SWEEP TO AMEMORY LOCATION.
13. REPEAT STEPS 1 THROUGH 12 FOR THE REST OF THE
TRANSMISSION LINES.
AN
f ION L&E DI FAULT
THIS TEST IS A PERFORMANCE VERIFICATION AND FAILURE ANALYSIS
TOOL FOR THE ANTENNA, TRANSMISSION LINES AND CONNECTORS.
TEST FREQUENCIES: 1`1=18W F2=19W
1. ENTER THE FREQUENCIES TO BE USED IN F1 AND F2.
2. RE -CALIBRATE TEST EQUIPMENT.
3. CONNECT THE TWO JUMPERS GOING TO THE ANTENNA (BYPASS
TMA) AND THE CABINET (BYPASS DUPLEXER) USING THE DIN (F)
TO DIN (F) CONNECTORS.
4. CONNECT THE ANTENNA TO THE LINE UNDER TEST.
5. CONNECT TEST EQUIPMENT TO THE LAST TX JUMPER
(YELLOW/RED) BEFORE THE CABINET, OF THE LINE UNDER TEST
6, PERFORM MEASUREMENT. VERIFY RESULTS WITH STEPS 10
THROUGH 13.
7. DISCONNECT TX JUMPER, THEN CONNECT THE RX JUMPER
(YELLOW/GREEN) TO DIN (F) ADAPTER
8. CONNECT TEST EQUIPMENT TO THE LAST RX JUMPER
(YELLOW/GREEN) BEFORE THE CABINET, OF THE LINE UNDER TEST
9. PERFORM MEASUREMENT. VERIFY RESULTS WITH STEPS 10
THROUGH 13.
10. VERIFY EACH DIN CONNECTOR HAS A RL LESS THEN -32DB,
N TYPE -28DB.
11. VERIFY THE TRANSMISSION LINE HAS A RL LESS THEN -45DB
12. VERIFY THE ANTENNA HAS A RL LESS THEN -17DB
13. RECORD PASS/FAIL ON SWEEP DATA SHEET, THEN SAVE
SWEEP TO A MEMORY LOCATION.
14. REPEAT STEPS 1 THROUGH 13 FOR THE REST OF THE
ANTENNA'S AND TRANSMISSION LINES
ENNA M RETURN LOSS:
THIS TEST MEASURES THE RL OF T14E TRANSMISSION LINE
TERMINATING INTO THE ANTENNA WITHOUT THE TMA AND
DUPLEXER.
TEST FREQUENCIES: Fl=1B50 F2=1990
1. ENTER THE FREQUENCIES TO BE USED IN Fl AND F2.
2. RE -CALIBRATE TEST EQUIPMENT.
3. CONNECT THE TWO JUMPERS GOING TO THE ANTENNA (BYPASS
TMA) AND THE CABINET (BYPASS DUPLEXER) USING THE DIN (F)
TO DIN (F) CONNECTORS.
4. CONNECT THE ANTENNA TO THE LINE UNDER TEST.
5. CONNECT TEST EQUIPMENT TO THE LAST TX JUMPER
(YELLOWIRED) BEFORE THE CABINET, OF THE LINE UNDER TEST.
6. PERFORM MEASUREMENT. VERIFY RESULTS WITH STEPS 10
THROUGH13.
7. DISCONNECT TX JUMPER, THEN CONNECT THE RX JUMPER
(YELLOWIGREEN) TO DIN (F) ADAPTER
8. CONNECT TEST EQUIPMENT TO THE LAST RX JUMPER
(YELLOW/GREEN )BEFORE THE CABINET, OF THE LINE UNDER
TEST
9. PERFORM MEASUREMENT. VERIFY RESULTS WITH STEPS 10
THROUGH 13.
10. VERIFY ANTENNA SYSTEM USING 1 5/8" WAVE -GUIDE HAS A
RL LESS THEN -17DB, 200FT MAX.
11. VERIFY ANTENNA SYSTEM USING 7/8" WAVE -GUIDE HAS A RL
LESS THEN -16DB, 200FT MAX.
12. FOR SYSTEMS ABOVE 200FT 1 5/8" RL -15 5DB, 718' RL
-14DB.
13. RECORD TEST RESULTS ON SWEEP DATA SHEET, THEN SAVE
SWEEP TO A MEMORY LOCATION.
14. REPEAT STEPS 1 THROUGH 13 FOR THE REST OF THE
ANTENNA SYSTEMS.
ANTENNA SYSTEM WITH t)uPLMP AND TLAA RETURN L,QSS-
THIS TEST MEASURES THE RL OF THE COMPLETE ANTENNA
NETWORK ON THE TX PATH.
TX TEST FREQUENCIES: Fi=1930 F2=1940
1. ENTER THE FREQUENCIES TO BE USED IN F1 AND F2.
2 RE -CALIBRATE TEST EQUIPMENT
3. REMOVE DIN (F) TO DIN (F) FROM BOTH TOP AND BOTTOM
JUMPERS.
4. CONNECT TOP JUMPERS TO TMA AND CONNECT BOTTOM
JUMPER TO DUPLEXER
-5. CONNECT TESTEQUIPMENT TO-TX-1 (YELLOWIRED):
6. PERFORM MEASUREMENT.
7. VERIFY ANTENNA NETWORK USING 1 5I8" WAVE -GUIDE HAS A
RL LESS THEN-15.SDB, 200FT MAX.
8, VERIFY ANTENNA NETWORK USING 71W WAVE -GUIDE HAS A
RL LESS THEN-14.5DB, 200FT MAX
9. FOR ANTENNA NETWORK ABOVE 20OFT 1 5/8" RL -14DB,
7/8" RL-12.5DB.
10. RECORD TEST RESULTS ON SWEEP DATA SHEET, THEN SAVE
SWEEP TO A MEMORY LOCATION.
11. REPEAT STEPS 1 THROUGH 10 FOR THE REST OF THE TX
ANTENNA NETWORKS.
ANTENNA SYSTEM WITH DUPLEXER AND TMA RETURN! LOSS:
THIS TEST MEASURES THE RL OF THE COMPLETE ANTENNA
NETWORK ON THE RX PATH. REMINDER THE TEST EQUIPMENT
WILLTERMINATE INTO THE TMA ON THE RX PATH.
RX TEST FREQUENCIES: F1=1850 F2=1860
1. ENTER THE FREQUENCIES TO BE USED IN Fl AND F2.
2 RE -CALIBRATE TEST EQUIPMENT
3. REMOVE DIN (F) TO DIN (F) FROM BOTH TOP AND BOTTOM
JUMPERS.
4, CONNECT TOP JUMPERS TO TMA AND CONNECT BOTTOM
JUMPER TO DUPLEXE:R.
5. CONNECT TEST EQUIPMENT TO RX 1 (YELLOWIGREEN).
6. PERFORM MEASUREMENT.
7. VERIFY ANTENNA NETWORK USING 1 518" WAVE -GUIDE HAS A
RL LESS THEN-16.5DB, 200FT MAX.
8. VERIFY ANTENNA NETWORK USING 7/8" WAVE -GUIDE HAS A
RL LESS THEN-15.51313, 200FT MAX.
9. FOR ANTENNA NETWORK ABOVE 200FT 1 5/8" RL-14DB,
7/8" RL-13_6DB.
10. RECORD TEST RESULTS ON SWEEP DATA SHEET, THEN SAVE
SWEEP TO A MEMORY LOCATION
11. REPEAT STEPS 1 THROUGH 10 FOR THE REST OF THE RX
ANTENNA NETWORKS.
TRANSMISSION LINE CONTINUITY TEST:
THIS TEST WILL VERIFY THE CON TINUIIY OF THE RX PATH
BETWEEN THE BTS AND THE TMA FOR THE 15 VDC
NETWORK.
1. CONNECT A SHORT AT THE END OF THE LAST JUMPER
BEFORE THE TMA, OF THE LINE UNDER TEST.
2. CONNECT MULTI -METER TO LAST JUMPER BEFORE THE
BTS, RX 1 (YELLOWIGREEN). PLACE THE BLACK LEAD ON
THE OUTER PART OF THE CONNECTOR AND THE RED LEAD
ON THE CENTER PIN OF THE CONNECTOR.
3, VERIFY THE METER READS A SHORT.
4. REMOVE SHORT AND VERIFY METER READS OPEN.
5. RECORD PASS/FAIL ON SWEEP DATA SHEET.
6. RE -CONNECT JUMPERS TO TMA AND BTS.
7. REPEAT STEPS 1 THROUGH 6 FOR THE REMAINING
RECEIVE PATHS.
NOTE: EDIT AND SAVE ALL SWEEPS TO A 3.5" DISKETTE AND
EMAIL SWEEPS TO JAMES.FUGATE@CINGULARCOM
PROVIDE A COPY OF
ANTENNA SYSTEM TEST RESULTS WITH DISKETTE ON FINAL
SITE WALK
QUESTIONS CONTACT:
JAMES FUGATE 206-240-9006
Q
MHA (TYP - REFER
SITE BUILD FORM)
TOP JUMPER CABLI
REQUIRED)
DIPLEXOR - -
(IF REQUIRED)
GROUNDING KIT -
GROUNDBAR
NEAR ANTENNAS
MAIN COAXIAL
CABLE(TYP)
O_
GROUNDBAR
NEAR EQUIPMENT
DIPLEXOR - -- - -
(IF REQUIRED)
BOTTOM JUMPER C
O
ANTENNA
ANTENNA
S
MHA (TYP - REFER TO RF
SITE BUILD -FORM) .-
TOP JUMPER CABLE (IF
REQUIRED)
- -GROUND BAR
NEAR ANTENNAS
GROUNDING KIT
MAIN COAXIAL CABLE (TYP)
O
GROUND BAR
NEAR EQUIPMENT
BOTTOM JUMPER
CABLE
3
uJ
W
. u
,ECEIV
_"" E3UILDIIVG � F
14201 NE 200th ST, =S91TE-200_-
WOODINVILLE, WA 98072
PH: 425.487.1732 FAK 425.487.173E
START DATE: osrtoms
DRAWN 6Y: J�
CHECKED BY- mwo
REVISIONS I
SITE
SC1808 (WA109)
ENCHANTED PKWY
1741 S 3561h ST
FEDERAL WAY, WA98003
- FSHEET TITLE
ANTENNA SWEEP TEST &
COAX MARKING
SHEET NUMBER
A-7
N
NAY
ELECTRICAL SPECIFICATION:
1 ALL ELECTRICAL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE
LATEST EDITION OF THE NATIONAL ELECTRICAL CODE.
2. COMPLY WITH THE LATEST EDITION OF THE UNIFORM BUILDING CODE, THE
REQUIREMENTS OF ALL APPLICABLE MUNICIPAL AND STATE CODES AND
REGULATIONS, AND UTILITY GUIDELINES.
3. PERFORM PILL VERIFICATION, OBSERVATIONS, TESTING AND EXAMINATION
OF WORK PRIOR TO THE ORDERING OF ELECTRICAL EQUIPMENT AND THE
ACTUAL CONSTRUCTION. ISSUE A WRITTEN NOTICE OF ALL FINDINGS TO THE
CONSTRUCTION MANAGER LISTING ALL MALFUNCTIONS, FAULTY EQUIPMENT
AND DISCREPANCIES.
4. ALL ELECTRICAL/ TELCO CONDUIL SHALL BE RIGID METAL CONDUIT (RMC)
TYPE CONFORMING TO UNDERWRITERS LABORATORIES STANDARD UL-6 AND
ASTM A-135: ALL CONDUITS SHALL COMPLY WITH NEC, ARTICLE 346. ALL
RIGID AND FLEXIBLE CONDUITS. AND -COUPLINGS SHALL OF F:O i DIPPED
GALVANIZED HAVING A HARD BAKED ENAMEL OR HEAVY LACQULR FINIS H.
BOTH INSIDE AND OUTSIDE. COUPLINGS SHALL BE THREADED TYPE,
GALVANIZED AND MADE FROM SAME GRADE OF MILD STEEL AS RMC. ALL
BENDS SHALL BE W MINIMUM RADIUS.
5. ALL WIRING SHALL BE STRANDED COPPER WITH MINIMUM 600V
INSULATION (UNLESS OTHERWISE NOTED).
6. NEUTRAL SHALL BE COLOR COOED, INSULATION SHALL BE CROSS -LINKED
POLYETHYLENE.
7. CONTRACTOR TO CONTACT ALL UTILITIES FOR LOCATION OF
UNDERGROUND SERVICES. SERVICE LOCATIONS TO BECONFIRMED PRIOR
TO CONSTRUCTION.
8. THE CONTRACTOR IS RESPONSIBLE FOR ALL PERMITTING, FILING, AND
FEES IN CONJUNCTION WITH THE PROJECT.
9. THE CONTRACTOR SHALL SCHEDULE ALL NECESSARY INSPECTIONS WITH
THE PROPER AUTHORITIES AND INFORM CINGULAR 24-HOURS IN ADVANCE.
ALL TICKETS AND INSPECTION VERIFICATIONS WILL BE SUBMITTED TO THE
OWNER'S REPRESENTA7�VE WITHIN 24-HOURS AFTER THE INSPECTION HAS
_.TAKER PLACE.
10. ALL EQUIPMENT, WIRING, AND MATERIALS MUST HAVE A UL LABEL
11. ALL WORK SHALL BE DONE BY QUALIFIED AND EXPERIENCED
JOURNEYMEN AND PERFORMED IN A WORKMANLIKE MANNER AND SHALL
PROCEED IN AN OR DERLY MANNER SO AS NOT TO HOLD UP THE PROGRESS
OF THE PROJECT.
12. THOROUGHLY TEST ALL LINES FEEDERS, EQUIPMENT, AND DEVICES WITH
MAXIMUM LOADS TO ASSURE PROPER OPERATION
13. CONDUCTOR LENGTHS SHALL BE CONTINUOUS FROM TERMINATION TO
TERMINATION WITHOUT SPLICES
14. PROVIDE PULL BOXES WHERE SHOWN ANDOR WHERE REQUIRED BY
CODES AND/OR UTILITY COMPANIES.
15. ALL CONDUIT ROUGH IN SHALL BE COORDINATED WITH THE MECHANICAL
EQUIPMENT TO AVOID LOCATION CONFLICTS CONTRACTOR SHALL VERIFY
ALL LOCATIONS
16. ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES, J-BOXES,
EQUIPMENT BOXES, AND CABINETS WITH APPROVED PLASTIC TAGS-
17. ALL BREAKERS IN PANEL BOXES SHALL BE IDENTIFIED WITH TYPE
WRITTEN LABELS NEATLY PLACED ALONG SIDE OF THE BREAKER.
18. ALL FIRE RATED WALL AND FLOOR PENETRATIONS ARE TO BE CAULKED
AND SEALED WITH A FIRE RESISTANT CAULKING TO MAINTAIN THE INTEGRITY
OF THE FIRE SEPARATION.
19. UTILIZE SONNESORN TYPE NP-1 CAULKING FOR SEALING ALL EXTERIOR
WALL PENETRATIONS
20. SUBCONTRACTOR SHALL SUPPLY AND INSTALL A 200# RATED NYLON
PULL CORD FOR FULL LENGTH OF ALL EMPTY CONDUIT OR AS REQUIRED BY
LOCAL UTILITY COMPANY.
ELECTRICAL SPECIFICATIONS
22x34 SCALE. NTS 1 ix17 SCALE: NTS
TRANSITION FROM 2- RM
TO LIQUIDTIGHT FLEX
METAL CONDUIT (TYP)
2 TELCO/POWER ROUTING
22x34 SCALE: 314" = t'-0' . —_ 1 t xi 7 SCALE:
IIII ; I a
) I
.�
I
(E) 200 AMP
SERVICE PANEL
PROPOSED 100AMP
2P BREAKER PANEL
FOR UMTS
- 2" RMC WI (2)-#2THHN,
(1)," THHN AND
(1)#6 GROUND
PROPOSED NEMA 3R
TELCO ENCLOSURE
W/ RMC TO (E)
TELCO DEMARC BOX
2" RMC W/ 24 TWISTED
PAIRS OF 24 AWG
SHIELDED TELCO CABLES
1
Loll
C i 20 it
Y OF FEDERAI v
�44261 N� z "WI WaMEP F.
%■;QODINVILLE, WA SAM
PH: ,25AEITA732 FAX:425.487-1734
START DATE ��
DRAWN BY: �RF
ECHECIL! p BY: r�wo
REVISIONS I
SITE
SC1808 (WA109)
ENCHANTED PKWY
1741 S 3561h ST
FEDERAL WAY, WA 98003
SHEET =DETAILS
ELECTRICAL
SHEET NUMBER
E-1
IAY
COAXIAL CABLES (TYP
2 PER ANTENNA) .-.
SECTOR A SECTOR B SECTOR C
(3) ANTENNAS (3) ANTENNAS (3) ANTENNAS
PER SECTOR PER SECTOR PER SECTOR
1 'I
I
E ,
(E) GROUND BAR
@ ANTENNA
COAX GROUND I l
WIRE (TYP)
I . #2 AWG SHIELDED
GROUND WIRE ON
! -ELECTt31CAL.1S.QLATFJ�S_
� 1 I
(E) GROUND BAR
@ BASE OF POLE
FI
#2 SOLID BARE . ,4"I
TINNED COPPER,'
�
GROUND WIRE
El1 /
(E)MGB
TO GROUND RING
(SEE TOWER GROUNDING
SCHEMATIC) r
TO (E) GROUND RING -
ANTENNA GROUNDING DIAGFMP,l
22x34 SCALE NTS I i ix17 SCALE: NTS
#2 SOLID BARE
TINNED COPPER
GROUND WIRE
TYPE GR
M1! -
TYPE SS
x-
1%
TYPE GL LUG
TYPE PT _. - . ..
_ ro
TYPE GT TYPE VS
NOTE: CADWELD "ES' SHOWN ABOVE ARE EXAMPLES -
CONSULT WITH PROJECT MANAGER FOR SPECIFIC TYPES OF
CADWELDS TO BE USED FOR THIS PROJECT.
CADWELD DETAILS
22x34 SCALE: NTS 111x17 SCALE: NTS
ANTENNA - ---
WEATHER SE
3' JUMPER
DIN MALES
GROUNDING
(E) #2 SOLIC
COPPER GF. .._... _
LEADS (TYPICAL)
NOTE: COAT ALL MECHANICAL CONNECTIONS
WITH'NOOX` OR APPROVED EQUAL
NEW COAXIAL GROUND KITS W1 LONG
BARREL COMPRESSION DOUBLE LUGS,
ATTACH TO GROUND BAR & INSTALL BY
% ANTENNA CONTRACTOR (CADWELD
TYPE-GL)
(E) 4"x 24"x 114" THK COPPER GROUND
BAR. INSTALLED BY GENERAL
CONTRACTOR
01
1-
c00c
0 0 0 3 0 0
0 0 0000--_.•:
l 0
00000
000000000000
U
O C 0 0 0 0
O O 0C
�._ J
--
-
- 24w•- .... _. _.......
.. ... - ._.__
FIELD VERIFY
�-
#2 SOLID BARE TINNED COPPER
WIRE CADWELD (TYPE-GL)
---
4 GROUND BAR CONNECTION DETAIL
2aM5CALE:NTS 11x17SCAUE-- i5
COPPER GROUND RING.
TOWER GROUNDING SCHEMATIC
22x34 SCALE: NTS I11x17SCALENTS
0
1
0
fA
O z
O
v
L
V
r
L �
- w
J
Ill
s
V
CEIVE
r.
,a2�n`11TY %A lIAY
wow PH:42&,W7.1732 F&vz4Z.4W.1734
START DATE:
BRAWN BY JRF
CHECKED BY. —w
**ALA
�. ExP9i6s____ RL7910G'
SITE
SC1808 (WA109)
ENCHANTED PKWY
1741 S 35M ST
FEDERAL WAY, WA 9MM
SHEET TITLE
GROUNDING DETAILS
SHEET NUMBER
E "2
Io
0
EXISTING 200 AMP PANEL
CIRCUIT DESCRIPTION A B CIRCUIT OESCRIPTION
SURGE SUPPRESOR 60A� 1 7 20A J LIGHTING
2 S 2QA GFI RECEPTACLE
LUCENT UMTS CABINET 100A 3 9 30A BTS
I 4 10
SUB -PANEL (SEE BELOW) 100A 5 11 30A BTS
6 12 -
:f 'J,
PROPOSED 100 AMP SUB -PANEL
CIRCUIT DESCRIPTION A
B
CIRCUIT DESCRIPTION
ARGUS TE20 PWR CABINET 30A 1 �
2 30A ARGUS TE20 PWR CABINET
ARGUS TE20 PWR CABINET 30A 3 +
B
4 ARGUS TE20 PWR CABINET
ARGUS TE20 PWR CABINET 30A 7
�9
I 10
12
30A ARGUS TE20PWRCABINET
f
♦_
_. ..
ARGUS TE20 PWR CABINET 30A 11
14
16
30A ARGUS TE20 PWR CABINET
--- - -
ARGUS TE20 PWR CABINET 30A 15
18
ARGUS TE20 PWR CABINET
_.
17
I
20
T30A
ARGUS TE20 PWR CABINET 3('° 19
22
30A ARGUS TE20 PWR CABINET
ARGUS TE20 PWR CABINET 30A 23
26
30A ARGUS TE20 PWR CABINET
2.5
28
27 l
0 o
30
ci o- - -
29
O o ..
32
t -
C O - - -
31
34
33
36
37
38
( 40
41
1 42
CIRCUIT PANEL SCHEDULE
2204 SCALE: NTS 111x17 SCALE: NTS
EXISTING PRIMARY
CONDUCTORS
FROM POWER SOURCE -
EXISTING 200A METER BASE
EXISTING MIAN DISCONNECT
PANEL
f I EXISTING CONDUCTORS
/ EX STING GENERATOR
MECHANICAL INTERLOCK • - RECEPTACLE
e
r — EXISTING 200 AMP 120/240V IPH
3W PANELBOARD
11/4" RMCW/(2)-#2THHN, i.._.. i
(1) - #6 THHN AND (1) -#6 GROUND
•� e 1 1DG�2P
700A.2P � I
—u
30 AMP 2P CIRCUIT BREAKER
(TYP OF 12)
2" RMC W/ (2) - #2 THHN,
(1) - #6 THHN AND (1) - #6'QROUND
TRANSITION FROM 2" RMC TO
LIQUIDTIGHT FLEXIBLE METAL
CONDUIT AFG, SEE NOTE 2. - -
ARGUS TE20
SITE SUPPORT
CABINET
2 ELECTRICAL ONE -LINE DIAGRAM
22x3d SCALE: NTS l lx17 SCALE: NTS
100AMP 120/240V 1PH. 3W,42
CCT PANELBOARD WITH NEMA 3R
LOCKABLE ENCLOSURE
EXISTING (1) - #4 AWG GROUND .r
TO GROUNDING SYSTEM --- --- -
2' RMC W/ (2) - #2 THHN,
(1) - #6 THHN AND (1) - #6 GROUND
r TRANSITION FROM 2"RMC TO
f LIQUIDTIGHT FLEXIBLE' METAL-'
CONDUIT AFG, SEE NOTE 2.
LUCENT UMTS
MODULAR CELL
CABINET
NOTES.
1. SUBCONTRACTOR SHALL SUPPLY 36" OF WATERTIGHT FLEX
CONDUIT WITH ALL CONDUIT FITTING (NUTS, REDUCING
BUSHINGS, ELBOWS, COUPLINGS, ETC.) NECESSARY FOR
CONNECTION TO THE EQUIPMENT CABINET.
2. SUBCONTRACTOR SHALL CUT, COIL AND TAPE A 10-FOOT
PIGTAIL FROM END OF FLEX CONDUIT FOR TERMINATION BY
EQUIPMENT INSTALLATION VENDOR
3. SUBCONTRACTOR SHALL SUPPLY AND INSTALLA2004 RATED
NYLON PULL CORD FOR FULL LENGTH OF ALL EMPTY CONDUIT
OR AS REQUIRED BY THE LOCAL UTILITY COMPANY.
1
K'61
J
_1 -.
i 1�
PH:424 �II 421i�$7.1739
START DATE 091
DRAWN BY.,
CHECKED BY:ro
,yx'W o
a 32 ¢
ExiNRES —_ tIQ175p'8 I
SITE
SC1806 (WA109)
ENCHANTED PKWY
1741 S 3561h ST
FEDERAL WAY, WA 98W3
SHEET TITLE
ELECTRICAL DETAILS
SHEET NUMBER
E-3
P(�e- Y-A(?,p �A/l
1 3 - C Ill Z-Y
(ZO) S357- Z7-70
2a-3 835- �u
CIO
w
Cn
w
O
cn
0
C
2
TI
m
0
m
D
r
i<
D I"
CTI
'o w
W v
00,
O O>
w
of A
N O
O
0 O
CITY OF
A Federal
November 2, 2005
Mr. Paul Wozniak
Odelia Pacific
208 Westlake Avenue North
Seattle, WA 98109
CITY HALL
33325 8th Avenue South • PO Box 9718
y Federal Way, WA 98063-9718
(253) 835-7000
www. cityoftederaiwa y. com
Re: PREAPPLICATION CONFERENCE MEETING — Files 05-105502-00-PC (South 288`h Street
PWSF); 05-105503-00-PC (Enchanted Parkway PWSF); 05-105504-00-PC (Steel Lake
PWSF); 05-105505-00-PC (Northeast Tacoma PWSF); & 05-105506 (Lakota PWSF)
Mr. Wozniak:
I have been assigned project planner for the preapplication conferences referenced above. You are
listed as the applicant and project contact for these projects. In order to keep the review process as
efficient as possible, I have scheduled all five projects for one, hour-long conference. Your
preapplication conference with the City's Development Review Committee (DRC) has been
scheduled for:
November 17, 2005 — 9:00 a.m. — Hylebos Conference Room
Federal Way City Hall
33325 8t1i Avenue South
PO Box 9718
Federal Way, WA 98063
Please confirm your attendance at ieff..iohnson@cityoffederalway.com, or 253-835-2626, and let
me know how many people will attend the meeting with you. Please check in with the receptionist
in the Permit Center when you arrive for the conference. We look forward to meeting with you,
and in the meantime, if you have any questions, feel free to call or e-mail.
Best ar
Jeff O. Johnson
Associate Planner
c: Phillip Kitzes, PK Enterprises, 23035 SE 263�d Street, Maple Valley, WA 98038
Doc. 1 D. 33887
A��
C'!f4' OF
Federal
MASTER LAND USE APPLICATION
DE " nMMMTYDEVELOPMENT SERVICES
, �' - 33325 Wh Avenue South
PO Box 9718
OCT 2 6 2005 Federal Way WA 98063-9718
253-835-2607; Fax 253-835-2609
CRY OF FEDEfIAL www.ci offederalwa .com
BUILDING DEFT. �!Y
'IliAPPLICATION NO(S) �9 �_ 5 Vy Date . 0 ,A 05
Project Name CL. [� �(� j �- W 4 10 1
Property Address/LocationSt
Parcel Number(s)
Project Description y 0
rKM 1
Type of Permit Required
Annexation
Binding Site Plan
Boundary Line Adjustment
Comp Plan/Rezone
Land Surface Modification
Lot Line Elimination
Preapplication Conference
Process I (Director-s Approval)
Process 11(Site Plan Review)
Process III (Project Approval)
_ Process IV (Hearing Examiner's Decision)
_ Process V (Quasi -Judicial Rezone)
Process VI
SEPA w/Project
SEPA Only
Shoreline: Variance/Conditional Use
Short Subdivision
_ Subdivision
Variance: Commercial/Residential
Required Information
Zoning Designation
komprehensive Plan Designation
>06)Valne of Existing irnproveuients
i! Value of Proposed Improvements
International Building Code (IBC):
Occupancy Type
Construction Type
Applicant
e,
- 0c-e-v ck �� ht����ec� �C���Lrl�(J�
Name: � 1
Address: 10 _--3 5 of UU
City/State: p,,,)�A0y\d
Zip: Q q U
Phone: �,
Fax: C�
Email: 5WtAo�orra�ftg
Signature:
Agent (if different than A� pplicant) ((°°
Name: PG 01 W o � h ► � �'� - erk l CU Pax- i `_ 1 C,
Address: �O c6 (J e S-f-1 � K e, AVZ, AJ
City/State: s cep+he, &04
Zip: Phone: q IO2
Fax: ?\0 6 _ 4- 47 3 ` 3 �!
Email: ';. o6 -A ct G _ 3$ ����
Signature: pwoe edK � .� r r z
Owner
Name: R L, Tro cz, Y\ N 7
Address: 711
City/State:
Zip:
Phone: �( 46 00 f3
Fax:
Email: f
Signature: ao
Bulletin #003 - August 18, 2004 Page 1 of 1 k \Handouts\Ivlaster Land Use Application
�jFCENED
O C T 2 9 209K ENTERPRISES
CITY OF WAY
BUILDNG DEPT.
October 28, 2005
Mr. Greg Fewins, Deputy Director
City of Federal Way
Community Development Department
33325 8t" Avenue South
Federal Way, WA 98063
b6 - I OS'D-
RE: Ciingular Project -Maintenance and Upgrades to Existing Wireless
Facilities within the City of Federal Way. 9��3'ZZC-A-A - 611
Dear Greg.
I spoke with Jim Harris this morning and he suggest 1 get in touch with you with
regard to a wireless project I am currently assisting on for Cingular. There are 4
existing sites within the city that require upgrading of both antennas and ground
equipment and need some assistance as to the submittal requirements. The
modifications include removal and replacement of antennas (similar in size) and
additional ground equipment (also area for future cabinets) within the existing
leased compound. At this point, there will be no modifications in the lease area;
thus, the existing screening will remain in tact.
Thank you for your consideration and we look forward to your response. I amavailableeel
to meet with you and/or your staff on this issue. If there are any questions, pleas
free to contact me at (206) 227-7445.
Sincerely,
PK ENTERPRISES
41
PHILLIP KITZES
23035 SE 263 d STREET • MAPLE VALLEY, WA • 98038