13-102624ESW 1/4, SEC 16, TWP 21, R4E W.M.
Y
CU
1
PRIVATE DRIVE
20+54.0
16.5' LT
30'
8'PRIVATE/
A
100 HPS
HPS
M-C-111
FIXED
SEE CITY OF FEDERAL WAY
DWG. NO.'S 3-38, 3-39 & 3-40
2
PRIVATE DRIVE
21 +63.5
16.5' LT
30'
8'
PRIVATE/100
A
HPS
HPS
M-C-111
FIXED
SEE CITY OF FEDERAL WAY
DWG. NO.'S 3-38, 3-39 & 3-40
3
PRIVATE DRIVE
22+43.5
16.5' LT
30'
8'
RIVATE/
A
100 HPS
HPS
M-C-111
FIXED
SEE CITY OF FEDERAL WAY
DWG. NO.'S 3-38, 3-39 & 3-40
4
S 333RD ST
EX.
EX.
30'
12'
PSE
100 HPS
M HCSIII
FIXED
T O B DE HOU� S DE SHIELD
NOTE: PRIVATE ILLUMINATION POLES (NOS. 1, 2, AND 3) TO BE LOCATED OUTSIDE OF RIGHT-OF-WAY ALONG THE PRIVATE DRIVEWAY.
GENERAL NOTES
1. ALL WORK SHALL BE IN PERFORMED IN ACCORDANCE WITH CITY OF FEDERAL WAY DESIGN AND CONSTRUCTION STANDARDS.
2. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY.
3. THE CONTRACTOR SHALL SUBMIT A REQUEST FOR MATERIALS APPROVAL TO THE CITY AT THE EARLIEST POSSIBLE DATE.
4. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY
AGENCIES 48 HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED
UTILITY COMPANY IMMEDIATELY UPON DAMAGE.
6. ILLUMINATION CONDUIT TO SHARE TRENCH/CROSSING WITH OTHER UTILITIES WHERE POSSIBLE, TYP. COORDINATE TRENCH SHARING WITH
THE GENERAL CONTRACTOR. CONDUIT CROSSING LOCATIONS TO BE VERIFIED BY THE CONTRACTOR.
7. APPLICANT SHALL COORDINATE LANDSCAPE PLAN AND PLANTING OF STREET TREES WITH THESE PLANS. STREET TREES SHALL NOT
INTERFERE WITH PROJECT LIGHTING CAPABILITIES.
8. ALL CONDUIT SHALL BE INSTALLED WITH MIN. 24" COVER.
9. SEE CITY OF FEDERAL WAY STANDARD PLANS 3-39 & 3-40 FOR POLE, JUNCTION BOX AND CONDUIT LAYOUT DETAILS. SEE STANDARD
PLAN 3-41 & 3-45 FOR SERVICE CABINET/CONNECTION DETAILS.
CONSTRUCTION NOTES
O1 PSE/INTOLIGHT TO INSTALL NEW LUMINAIRE ON EXISTING POWER POLE. CONTRACTOR SHALL COORDINATE WITH PSE/INTOLIGHT TO
ENSURE INSTALLATION, INCLUDING PAYMENT OF ALL FEES AND COMPLETING ALL APPLICATIONS. SEE ILLUMINATION POLE SCHEDULE FOR
MOUNTING HEIGHT, WATTAGE, AND ARM LENGTH.
OINSTALL PRIVATELY OWNED LUMINAIRE, POLE AND FOUNDATION PER CITY OF FEDERAL WAY STANDARD PLANS 3-38, 3-39 & 3-40 AND
PER ILLUMINATION POLE SCHEDULE, THIS SHEET.
OINSTALL PRIVATELY OWNED METERED ELECTRICAL SERVICE CABINET AT THE LOCATION SHOWN, PER CITY OF FEDERAL WAY STANDARD
PLANS 3-41 & 3-45.
OINSTALL PHOTOCELL ON LUMINAIRE.
OCONTRACTOR SHALL INSTALL CONDUIT AND CONDUCTORS TO POWER SOURCE AND COORDINATE CONNECTION WITH PUGET SOUND ENERGY
(PSE). PSE TO PROVIDE 1201240V SINGLE PHASE POWER SOURCE. THE LOCATION OF THE POWER SOURCE WAS NOT KNOW AT THE
TIME OF PLAN PREPARATION. THE CONTRACTOR SHALL COORDINATE WITH PSE TO DETERMINE THE LOCATION OF THE POWER SOURCE,
INCLUDING PAYMENT OF ALL FEES AND COMPLETING ALL APPLICATIONS.
4TH
Av E S
STREET LIGHTING NOTES
1. The Contractor shall acquire an .electrical Permit from. the City's building Department. The .electrical Permit shall
be kept in the upper bay of the service cabinet.
2. Upon. completion of underground installation of power from power vault or pole to service cabinet, contractor shall
notify the building Department. Upon Final Electrical Permit approval, the electrical inspector will place an
approval tag next to the meter base so that electrical service can be authorized.
3. The Contractor shall coordinate power source and service location with the utility company.
4. The Contractor shall contact the Utilities Underground Location Center (1-800-424-5555) at least 3 days before
digging..
5. Field adjust pole bases to be level with sidewalk surface (see City Standard Drawings 3-39A and 3-43).
6. Locate light poles so that the pole is a minimum of sic (6) feet behind the face of curb, and the luminaire extends
two (2) feet, beyond the face of curb. Light poles shall not be located within the sidewalk. Pole bases may be located.
within the sidewalk only with City approval.
7. Junction boxes shall be located behind the sidewalk, and within five (5) feet of the pole.
8. Conduit shall be Schedule 80 PVC under all streett and driveway crossings. Schedule 40 PVC conduit is acceptable
under landscaped areas.
9. Immediately following final inspection of the street light system by King County, all street light system J-boxes
shall be spot welded shut using a 1" weld on opposite corners.
JUNCTION BOX CIRCUIT A
(n'P')� F-2-J48 PRIVATE SERVICE
WIRING DIAGRAM
NOT TO SCALE
LUMINAIRE
(rn'•)
ILLUMINATION LEGEND
EXIST. BE�,l
DESCR/PT10N
® ®
JUNCTION BOX TYPE 1, 2
®
ELECTRICAL SERVICE CABINET
ALUMINAIRE
POLE
LUMINAIRE ON WOOD POLE
WOOD POLE
CONDUIT/CONDUCTOR
OCONSTRUCTION
NOTE
OPOLE
NUMBER
AWIRE
NOTE
Q
JUNCTION BOX ID
BREAKER SCHEDULE (PRIVATE SERVICE)
SERVICE &
CIRCUITS
MAIN
BREAKER
BRANCH
BREAKER
CONTACTOR
AMPS
COMMENTS
AMPS
AMPS
SERVICE
100
ILLUM A
20
30
ILLUM B (SPARE
20
30
ILLUM C (SPARE
20
30
ILLUMINATION
WIRING SCHEDULE
RACEWAY
IZE U1T
SVC.
POWER
ILLUM.
0
PHOTO
114
EQQUIP.
GRND.
COMMENT
NO.
1
2" SCH40 PVC
2
1-08
2
2" SCH40 PVC
2 1
3
1 1-0
3
2" SCH40 PVC
3
4
2" SCH80 PVC
2 1
1
1-08
JUNCTION BOX SCHEDULE
-BOXREFERENCE
ID
ROADWAY
STATION
OFFSET
J-BOX
TYPE
COMMENT
A
PRIVATE DRIVE
20+58.0
17.0' LT
1
DWG. N0. INSTALL PER 3-40. CITY OF FEDERAL WAY
B
PRIVATE DRIVE
21 +59.5
17.0' LT
1
INSTALL PER CITY OF FEDERAL WAY
DWG. NO. 3-40.
C
PRIVATE DRIVE
22+39.5
17.0' LT
2
INSTALL PER CITY OF FEDERAL WAY
DWG. NO. 3-40.
i
10 40
6�� - 0 109
0 20 60
SCALE IN FEET
CALL 48 HOURS
BEFORE YOU DIG
1-800-424-5555
m
APPROVED RY
DATE
z
0
a
110
0
W
z
0
O
z
`_'
Z
Q
z
z
3:
Q
O
-j
>-
z
Q
O
J
Q
Q
nro
_Z
Q
ZD
z
W
U.
J
U
0
z
��
Y
CLIENT
DREAM BUILDERS NW
MR. SCOTT ROBERTS
110 STEWART AVE. EAST
PUYALLUP, WA 98371
PHONE: (253) 677-2800
� w
_ Q CL
PN��
N mo-a� Ug g:Ro,
LO
7'
W jU�N
> C.6 U '
W Q} dU+_CV
ip Z
o O 0
t Z t
o a�tM o 0
(2c§ U .E
o~tea } CL
C U
2 ~ °0 )
PROJECT NO.
3284 a i Z013
DRAWING I L� �F FEDERAL JAY• CDS
SHEET IL1 OF 2