13-102624ESW 1/4, SEC 16, TWP 21, R4E W.M. Y CU 1 PRIVATE DRIVE 20+54.0 16.5' LT 30' 8'PRIVATE/ A 100 HPS HPS M-C-111 FIXED SEE CITY OF FEDERAL WAY DWG. NO.'S 3-38, 3-39 & 3-40 2 PRIVATE DRIVE 21 +63.5 16.5' LT 30' 8' PRIVATE/100 A HPS HPS M-C-111 FIXED SEE CITY OF FEDERAL WAY DWG. NO.'S 3-38, 3-39 & 3-40 3 PRIVATE DRIVE 22+43.5 16.5' LT 30' 8' RIVATE/ A 100 HPS HPS M-C-111 FIXED SEE CITY OF FEDERAL WAY DWG. NO.'S 3-38, 3-39 & 3-40 4 S 333RD ST EX. EX. 30' 12' PSE 100 HPS M HCSIII FIXED T O B DE HOU� S DE SHIELD NOTE: PRIVATE ILLUMINATION POLES (NOS. 1, 2, AND 3) TO BE LOCATED OUTSIDE OF RIGHT-OF-WAY ALONG THE PRIVATE DRIVEWAY. GENERAL NOTES 1. ALL WORK SHALL BE IN PERFORMED IN ACCORDANCE WITH CITY OF FEDERAL WAY DESIGN AND CONSTRUCTION STANDARDS. 2. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY. 3. THE CONTRACTOR SHALL SUBMIT A REQUEST FOR MATERIALS APPROVAL TO THE CITY AT THE EARLIEST POSSIBLE DATE. 4. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY IMMEDIATELY UPON DAMAGE. 6. ILLUMINATION CONDUIT TO SHARE TRENCH/CROSSING WITH OTHER UTILITIES WHERE POSSIBLE, TYP. COORDINATE TRENCH SHARING WITH THE GENERAL CONTRACTOR. CONDUIT CROSSING LOCATIONS TO BE VERIFIED BY THE CONTRACTOR. 7. APPLICANT SHALL COORDINATE LANDSCAPE PLAN AND PLANTING OF STREET TREES WITH THESE PLANS. STREET TREES SHALL NOT INTERFERE WITH PROJECT LIGHTING CAPABILITIES. 8. ALL CONDUIT SHALL BE INSTALLED WITH MIN. 24" COVER. 9. SEE CITY OF FEDERAL WAY STANDARD PLANS 3-39 & 3-40 FOR POLE, JUNCTION BOX AND CONDUIT LAYOUT DETAILS. SEE STANDARD PLAN 3-41 & 3-45 FOR SERVICE CABINET/CONNECTION DETAILS. CONSTRUCTION NOTES O1 PSE/INTOLIGHT TO INSTALL NEW LUMINAIRE ON EXISTING POWER POLE. CONTRACTOR SHALL COORDINATE WITH PSE/INTOLIGHT TO ENSURE INSTALLATION, INCLUDING PAYMENT OF ALL FEES AND COMPLETING ALL APPLICATIONS. SEE ILLUMINATION POLE SCHEDULE FOR MOUNTING HEIGHT, WATTAGE, AND ARM LENGTH. OINSTALL PRIVATELY OWNED LUMINAIRE, POLE AND FOUNDATION PER CITY OF FEDERAL WAY STANDARD PLANS 3-38, 3-39 & 3-40 AND PER ILLUMINATION POLE SCHEDULE, THIS SHEET. OINSTALL PRIVATELY OWNED METERED ELECTRICAL SERVICE CABINET AT THE LOCATION SHOWN, PER CITY OF FEDERAL WAY STANDARD PLANS 3-41 & 3-45. OINSTALL PHOTOCELL ON LUMINAIRE. OCONTRACTOR SHALL INSTALL CONDUIT AND CONDUCTORS TO POWER SOURCE AND COORDINATE CONNECTION WITH PUGET SOUND ENERGY (PSE). PSE TO PROVIDE 1201240V SINGLE PHASE POWER SOURCE. THE LOCATION OF THE POWER SOURCE WAS NOT KNOW AT THE TIME OF PLAN PREPARATION. THE CONTRACTOR SHALL COORDINATE WITH PSE TO DETERMINE THE LOCATION OF THE POWER SOURCE, INCLUDING PAYMENT OF ALL FEES AND COMPLETING ALL APPLICATIONS. 4TH Av E S STREET LIGHTING NOTES 1. The Contractor shall acquire an .electrical Permit from. the City's building Department. The .electrical Permit shall be kept in the upper bay of the service cabinet. 2. Upon. completion of underground installation of power from power vault or pole to service cabinet, contractor shall notify the building Department. Upon Final Electrical Permit approval, the electrical inspector will place an approval tag next to the meter base so that electrical service can be authorized. 3. The Contractor shall coordinate power source and service location with the utility company. 4. The Contractor shall contact the Utilities Underground Location Center (1-800-424-5555) at least 3 days before digging.. 5. Field adjust pole bases to be level with sidewalk surface (see City Standard Drawings 3-39A and 3-43). 6. Locate light poles so that the pole is a minimum of sic (6) feet behind the face of curb, and the luminaire extends two (2) feet, beyond the face of curb. Light poles shall not be located within the sidewalk. Pole bases may be located. within the sidewalk only with City approval. 7. Junction boxes shall be located behind the sidewalk, and within five (5) feet of the pole. 8. Conduit shall be Schedule 80 PVC under all streett and driveway crossings. Schedule 40 PVC conduit is acceptable under landscaped areas. 9. Immediately following final inspection of the street light system by King County, all street light system J-boxes shall be spot welded shut using a 1" weld on opposite corners. JUNCTION BOX CIRCUIT A (n'P')� F-2-J48 PRIVATE SERVICE WIRING DIAGRAM NOT TO SCALE LUMINAIRE (rn'•) ILLUMINATION LEGEND EXIST. BE�,l DESCR/PT10N ® ® JUNCTION BOX TYPE 1, 2 ® ELECTRICAL SERVICE CABINET ALUMINAIRE POLE LUMINAIRE ON WOOD POLE WOOD POLE CONDUIT/CONDUCTOR OCONSTRUCTION NOTE OPOLE NUMBER AWIRE NOTE Q JUNCTION BOX ID BREAKER SCHEDULE (PRIVATE SERVICE) SERVICE & CIRCUITS MAIN BREAKER BRANCH BREAKER CONTACTOR AMPS COMMENTS AMPS AMPS SERVICE 100 ILLUM A 20 30 ILLUM B (SPARE 20 30 ILLUM C (SPARE 20 30 ILLUMINATION WIRING SCHEDULE RACEWAY IZE U1T SVC. POWER ILLUM. 0 PHOTO 114 EQQUIP. GRND. COMMENT NO. 1 2" SCH40 PVC 2 1-08 2 2" SCH40 PVC 2 1 3 1 1-0 3 2" SCH40 PVC 3 4 2" SCH80 PVC 2 1 1 1-08 JUNCTION BOX SCHEDULE -BOXREFERENCE ID ROADWAY STATION OFFSET J-BOX TYPE COMMENT A PRIVATE DRIVE 20+58.0 17.0' LT 1 DWG. N0. INSTALL PER 3-40. CITY OF FEDERAL WAY B PRIVATE DRIVE 21 +59.5 17.0' LT 1 INSTALL PER CITY OF FEDERAL WAY DWG. NO. 3-40. C PRIVATE DRIVE 22+39.5 17.0' LT 2 INSTALL PER CITY OF FEDERAL WAY DWG. NO. 3-40. i 10 40 6�� - 0 109 0 20 60 SCALE IN FEET CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 m APPROVED RY DATE z 0 a 110 0 W z 0 O z `_' Z Q z z 3: Q O -j >- z Q O J Q Q nro _Z Q ZD z W U. J U 0 z �� Y CLIENT DREAM BUILDERS NW MR. SCOTT ROBERTS 110 STEWART AVE. EAST PUYALLUP, WA 98371 PHONE: (253) 677-2800 � w _ Q CL PN�� N mo-a� Ug g:Ro, LO 7' W jU�N > C.6 U ' W Q} dU+_CV ip Z o O 0 t Z t o a�tM o 0 (2c§ U .E o~tea } CL C U 2 ~ °0 ) PROJECT NO. 3284 a i Z013 DRAWING I L� �F FEDERAL JAY• CDS SHEET IL1 OF 2