23-101976-AD-Field Lighting Calculations-04-13-2023-v1PROJECT SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: D. Lohman · File #217688A · 10-Apr-22 Federal Way Stadium Federal Way,WA LighƟng System Pole / Fixture Summary Pole ID Pole Height Mtg Height Fixture Qty Luminaire Type Load Circuit F1-F4 100'100'10 TLC-LED-1500 14.30 kW A 16'2 TLC-BT-575 1.15 kW A 4 48 61.80 kW Circuit Summary Circuit Description Load Fixture Qty A Football 61.8 kW 48 Fixture Type Summary Type Source Wattage Lumens L90 L80 L70 Quantity TLC-LED-1500 LED 5700K - 75 CRI 1430W 160,000 >120,000 >120,000 >120,000 40 TLC-BT-575 LED 5700K - 75 CRI 575W 52,000 >120,000 >120,000 >120,000 8 Light Level Summary Calculation Grid Summary IlluminationGrid Name Calculation Metric Ave Min Max Max/Min Ave/Min Circuits Fixture Qty Football Horizontal Illuminance 50.7 42 55 1.31 1.21 A 48 Soccer Horizontal Illuminance 50.3 42 55 1.30 1.20 A 48 Spill Horizontal 0 0 0.01 0.00 A 48 Spill Max Candela (by Fixture)82.9 0 986 0.00 A 48 Spill Max Vertical Illuminance Metric 0 0 0.02 0.00 A 48 Track Horizontal Illuminance 26.9 3 46 13.61 8.98 A 48 100' Pole Height ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: D. Lohman · File #217688A · 10-Apr-22 53 48 43 42 46 53 54 54 52 51 53 52 51 51 50 49 49 47 55 51 49 48 50 52 54 52 50 50 51 52 53 53 52 51 52 51 53 53 52 51 52 51 54 52 50 50 51 52 55 51 49 48 50 52 51 51 50 49 49 47 54 54 52 51 53 52 53 48 43 42 46 53 1010 2020 3030 4040 5050 4040 3030 2020 1010 150'155'150'155'160'155'160'155' F2F1 F4 F3 SCALE IN FEET 1 : 80 0'80'160' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS4F1-F4 100'-15.5' 100' TLC-BT-575 TLC-LED-1500 2 10 2 10 0 0 4 TOTALS 48 48 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Federal Way Stadium Federal Way,WA GRID SUMMARY Name: Football Size: 360' x 160' Spacing: 30.0' x 30.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Guaranteed Average:50 Scan Average:50.72 Maximum:55 Minimum:42 Avg / Min:1.21 Guaranteed Max / Min:2 Max / Min:1.31 UG (adjacent pts):1.22 No. of Points:72 LUMINAIRE INFORMATION Applied Circuits: A No. of Luminaires: 48 Total Load: 61.8 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. 100' Pole Height ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: D. Lohman · File #217688A · 10-Apr-22 1010 2020 3030 4040 5050 4040 3030 2020 1010 50 51 45 42 44 50 52 50 55 53 52 52 53 49 48 51 50 50 49 49 44 55 53 49 49 49 52 52 53 53 51 50 50 52 50 50 54 52 51 51 52 48 50 54 52 51 51 52 48 53 53 51 50 50 52 50 55 53 49 49 49 52 52 48 51 50 50 49 49 44 50 55 53 52 52 53 49 50 51 45 42 44 50 52150'155'150'155'160'155'160'155' F2F1 F4 F3 SCALE IN FEET 1 : 80 0'80'160' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS4F1-F4 100'-15.5' 100' TLC-BT-575 TLC-LED-1500 2 10 2 10 0 0 4 TOTALS 48 48 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Federal Way Stadium Federal Way,WA GRID SUMMARY Name: Soccer Size: 348' x 195' Spacing: 30.0' x 30.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Guaranteed Average:50 Scan Average:50.32 Maximum:55 Minimum:42 Avg / Min:1.19 Guaranteed Max / Min:2 Max / Min:1.30 UG (adjacent pts):1.23 No. of Points:84 LUMINAIRE INFORMATION Applied Circuits: A No. of Luminaires: 48 Total Load: 61.8 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. 100' Pole Height ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: D. Lohman · File #217688A · 10-Apr-22 1010 2020 3030 4040 5050 4040 3030 2020 1010 34 32 36 46 42 37 38 44 44 33 34 31 23 19 18 18 17 17 15 15 17 2829273541373436413628292818 15 15 17 17 17 18 19 22 31 8 3150'155'150'155'160'155'160'155' F2F1 F4 F3 SCALE IN FEET 1 : 80 0'80'160' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS4F1-F4 100'-15.5' 100' TLC-BT-575 TLC-LED-1500 2 10 2 10 0 0 4 TOTALS 48 48 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Federal Way Stadium Federal Way,WA GRID SUMMARY Name: Track Size: Irregular Spacing: 30.0' x 30.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Scan Average:26.93 Maximum:46 Minimum:3 Avg / Min:7.99 Max / Min:13.61 UG (adjacent pts):0.00 No. of Points:46 LUMINAIRE INFORMATION Applied Circuits: A No. of Luminaires: 48 Total Load: 61.8 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. 100' Pole Height ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: D. Lohman · File #217688A · 10-Apr-22 MATCHLINEPROPERTY LINE FROM SURVEYALIGN WITH SOUTHWEST PROPERTY CORNER IN SURVEY1010 2020 3030 4040 5050 4040 3030 2020 1010 F2F1 F4 F3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 SCALE IN FEET 1 : 150 0'150'300' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS4F1-F4 100'-15.5' 100' TLC-BT-575 TLC-LED-1500 2 10 2 10 0 0 4 TOTALS 48 48 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Federal Way Stadium Federal Way,WA GRID SUMMARY Name: 100ft Poles Spill Spacing: 30.0' Height: 3.0' above grade ILLUMINATION SUMMARY HORIZONTAL FOOTCANDLES EnƟre Grid Scan Average:0.0005 Maximum:0.01 Minimum:0.00 No. of Points:107 LUMINAIRE INFORMATION Applied Circuits: A No. of Luminaires: 48 Total Load: 61.8 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. 100' Pole Height ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: D. Lohman · File #217688A · 10-Apr-22 MATCHLINEPROPERTY LINE FROM SURVEYALIGN WITH SOUTHWEST PROPERTY CORNER IN SURVEY1010 2020 3030 4040 5050 4040 3030 2020 1010 F2F1 F4 F3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 SCALE IN FEET 1 : 150 0'150'300' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS4F1-F4 100'-15.5' 100' TLC-BT-575 TLC-LED-1500 2 10 2 10 0 0 4 TOTALS 48 48 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Federal Way Stadium Federal Way,WA GRID SUMMARY Height: 3.0' above grade ILLUMINATION SUMMARY MAX VERTICAL FOOTCANDLES EnƟre Grid Scan Average:0.0015 Maximum:0.02 Minimum:0.00 No. of Points:107 LUMINAIRE INFORMATION Applied Circuits: A No. of Luminaires: 48 Total Load: 61.8 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. Name: 100ft Poles Spill Spacing: 30.0' 100' Pole Height ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: D. Lohman · File #217688A · 10-Apr-22 MATCHLINEPROPERTY LINE FROM SURVEYALIGN WITH SOUTHWEST PROPERTY CORNER IN SURVEY1010 2020 3030 4040 5050 4040 3030 2020 1010 F2F1 F4 F3 12 3 15 0 2 11 22 9 0 21 16 2 0 10 3 0 1 0 3 15 0 2 11 0 10 3 1 0 24 22 20 16 11 3 2 2 1 1 1 1 2 4 4 4 8 19 35 80 158 299 440 630 898 973 956 986 929 716 482 347 204 86 43 25 6 4 4 4 5 1 1 1 1 1 4 16 1 0 7 1 0 8 14 2 0 7 15 25 31 26 14 6 6 0 7 13 8 1 1 2 4 6 5 7 SCALE IN FEET 1 : 150 0'150'300' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS4F1-F4 100'-15.5' 100' TLC-BT-575 TLC-LED-1500 2 10 2 10 0 0 4 TOTALS 48 48 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Federal Way Stadium Federal Way,WA GRID SUMMARY Height: 3.0' above grade ILLUMINATION SUMMARY CANDELA (PER FIXTURE) EnƟre Grid Scan Average: 82.8650 Maximum:986.22 Minimum:0.00 No. of Points:107 LUMINAIRE INFORMATION Applied Circuits: A No. of Luminaires: 48 Total Load: 61.8 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. Name: 100ft Poles Spill Spacing: 30.0' 100' Pole Height EQUIPMENT LAYOUT Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: D. Lohman · File #217688A · 10-Apr-22 MATCHLINEPROPERTY LINE FROM SURVEYALIGN WITH SOUTHWEST PROPERTY CORNER IN SURVEYFootball 360' x 160' 1010 2020 3030 4040 5050 4040 3030 2020 1010 F2F1 F4 F3 Soccer 348' x 195' Track SCALE IN FEET 1 : 100 0'100'200' Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Federal Way Stadium Federal Way,WA EQUIPMENT LAYOUT INCLUDES: · Football · Soccer · Track Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE 4 F1-F4 100'-15.5' 100' TLC-BT-575 TLC-LED-1500 2 10 4 TOTALS 48 SINGLE LUMINAIRE AMPERAGE DRAW CHART Ballast SpeciĮcaƟons (.90 min power factor) Line Amperage Per Luminaire (max draw) Single Phase Voltage 208 (60) 220 (60) 240 (60) 277 (60) 347 (60) 380 (60) 480 (60) TLC-LED-1500 8.5 8.1 7.4 6.4 5.1 4.7 3.7 TLC-BT-575 3.4 3.2 2.9 2.5 2.0 1.8 1.5 100' Pole Height G. PRODUCT INFORMATION Federal Way Stadium,217688 Datasheet: Light-Structure System™ 1 www.musco.com · lighting@musco.com TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States. ©2015, 2019 Musco Sports Lighting, LLC · U.S. and foreign patent(s) issued and pending. · M-2214-en04-3 2 1 3 4 5 Precast Concrete Base Galvanized Steel Pole Electrical Components Enclosure Poletop Luminaire Assembly Wire Harness 5 Easy Pieces™ Complete System from Foundation to Poletop Factory wired, aimed, and tested Fast, trouble-free installation Comprehensive corrosion package Integrated lightning ground TLC for LED® Datasheet: Light-Structure System™ www.musco.com · lighting@musco.com TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States. ©2012, 2019 Musco Sports Lighting, LLC · U.S. patents issued. · M-2215-en04-3 1 DRAFT 01_11-04-2016_JVS TLC for LED® – Precast Concrete Base Overview The precast concrete base is set directly into the ground and backfilled with concrete. The base includes an integrated lightning ground system. Features Base •Set pole on base in 24 hours •Tapered upper section for slip-fit steel pole •Access holes for wire entry •Epoxy-coated ends prevent water intrusion •Lifting hole accepts load-rated steel rod provided by Musco Integrated Lightning Ground System •Complies with NFPA 780, UL 96A, and EN 62305 standards when installed per Musco installation instructions •UL Listed, Class II Lightning Protection, file number E337467 •Tested up to 100 kA by independent laboratory •Steel pole interfaces with integrated grounding system by means of the pole grounding connector •2/0 AWG (crossectional area of 67.4 mm2) grounding electrode conductor •Concrete-encased grounding electrode, 20 feet (6.1 m) total length, 1/2 inch (12.7 mm) diameter Technical Specifications Base dimensions vary. For measurements refer to project-specific Foundation and Pole Assembly drawing. Construction •Spun concrete construction •Prestressed steel vertical strands and coil spiral for strength throughout base •Minimum design strength is 9500 lb/in² (65.5 MPa) at 28 days •Meets ASTM C1804 design requirements Quality Assurance Tests •28-day compressive strength •Bending moment capacity •Grounding system continuity 5 Easy Pieces™ 54321 www.musco.com · lighting@musco.com TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States. ©2005, 2019 Musco Sports Lighting, LLC · M-2216-en04-3 Datasheet: Light-Structure System™ 1 TLC for LED® – Galvanized Steel Pole Overview The galvanized steel pole is designed to slip-fit together with the precast concrete base and the poletop luminaire assembly. Features •Slip-fit connection allows pole assembly with come-alongs •Built-in hardware for attaching electrical components enclosure •Wire access from inside the pole (no exposed wiring or conduit) •Shipped in sections for easier handling •Labeled with pole identification for location on field Technical Specifications Pole dimensions vary. For measurements refer to project specific pole configuration drawing. Construction •Pole designs comply with all major building codes •High strength, low alloy, tapered, round steel pole •Hot-dip galvanizing inside and outside after fabrication meets ASTM-A123 and EN 1461 standards •Conforms to AASHTO stress standards and BS EN 40-3-1 •Grounding lug—rated for aluminum (AL) or copper (CU) wiring •Pole shipped in sections •Stainless steel fasteners passivated and coated •Material certifications are available Quality Assurance Tests •Bending stress •Minimum galvanizing thickness •Straightness measurement 5 Easy Pieces™ 54312 Datasheet: Light-Structure System™ www.musco.com · lighting@musco.com TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States. ©2015, 2019 Musco Sports Lighting, LLC · ECE 9 · M-2217-en04-3 1 TLC for LED® – Electrical Components Enclosure 5 Easy Pieces™ 54213 Overview The electrical components enclosure contains all necessary equipment to operate luminaires. Built-in mounting hardware allows for easy attachment to the galvanized steel pole. Quick connect plugs fasten to the wire harness. Features •Factory-built and tested as a unit •Quick connect plug for easy field wiring •Mounted 10 ft (3 m) above grade for servicing with ladder •Labeled with pole identification and electrical information •Drivers individually fused and spare fuses supplied •Wire access from inside the pole (no exposed wiring or conduit) •Disconnect per circuit Technical Specifications For amperage draws and circuitry refer to project specific document. Construction •0.08 inch (2 mm) thick, powder-coated aluminum •Enclosure ratings: NEMA 3R, IP54 •Designed to operate in up to 50˚ C (122˚ F) ambient temperature •Full length stainless steel hinge •All stainless steel fasteners passivated and coated •Meets touchsafe standards •Up to four drivers per enclosure •Approximate weight 65 lb (29 kg) •Lower enclosure size 14.25 in (362 mm) wide x 8 in (203 mm) deep x 52.5 in (1334 mm) high •Upper enclosure size 14.25 in (362 mm) wide x 8 in (203 mm) deep x 40.5 in (1029 mm) high Quality Assurance Tests •Grounding continuity •High potential dielectric withstand •Full functionality test F1 Datasheet: Light-Structure System™ www.musco.com · lighting@musco.com TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States. ©2005, 2019 Musco Sports Lighting, LLC · M-2218-en04-3 TLC for LED® – Wire Harness 5 Easy Pieces™ 51324 2 Top quick connector Wire tie Top cable support grip Spiral wound cable consisting of 14 AWG (cross-sectional area of 2.08 mm2) copper wire Mid-point cable support grip for poles 80 ft (24.5 m) and taller Flexible protective sleeve Bottom quick connector Wire harness bottom quick connector Cable support grip and snap hook Cable support grip and snap hook (if required) Wire harness top quick connector Enclosure harness quick connector Bar harness quick connector www.musco.com · lighting@musco.com TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States. ©2015, 2019 Musco Sports Lighting, LLC · U.S. and foreign patent(s) issued and pending. · M-2219-en04-3 Datasheet: Light-Structure System™ 1 TLC for LED® – Poletop Luminaire Assembly, Weld On Overview The factory-aimed poletop luminaire assembly is the upper section of the pole and slip-fits together with the galvanized steel pole. Features •Each luminaire is factory-built, tested, and ships as a unit •Luminaires are factory-aimed to two-tenths degree of accuracy •Luminaire mounts and connects in a single step •Slip-fit connection allows assembly with come-alongs •All luminaires are factory-wired to a quick connect harness for easy installation •Labels identify pole and luminaire location •No exposed wiring or conduit •Factory-set pole alignment beam allows easy field alignment Technical Specifications Construction •Crossarms and pole shaft hot-dip galvanizing inside and outside after fabrication meets ASTM-A123 and EN 1461 standards •All aluminum components are powder-coated or anodized to mil-A-8625F and BS 5599 •Luminaire and knuckle are powder-coated die-cast aluminum •All stainless steel fasteners are passivated and coated •Crossarms are constructed of rectangular steel tubing •Polecap is attached with stainless steel lanyard and securing bolt Quality Assurance Tests •Galvanizing thickness •High potential dielectric withstand •Electrical continuity 5 Easy Pieces™ 4132 5 Luminaire and Driver – TLC-BT-575 All components from foundation to poletop are designed to work together in Light-Structure System™ to ensure reliable, trouble-free operation. Luminaire Data Weight (luminaire) 34 lb (15 kg) UL listing number E338094 UL listed for USA/Canada UL1598 CSA-C22.2 No.250.0 CE Declaration LVD, EMC, RoHS Ingress protection (luminaire)IP65 Impact rating IK07 Material and finish Aluminum, powder-coat painted Wind speed rating (aiming only)150 mi/h (67 m/s) UL, IEC ambient temperature rating (luminaire)50°C (122°F) Photometric Characteristics Projected lumen maintenance per IES TM-21-11 L90 (20k)>120,000 h L80 (20k)>120,000 h L70 (20k)>120,000 h Lumens1 52,000 CIE correlated color temperature 5700 K Color rendering index (CRI)75 typ, 70 min LED binning tolerance 7-step MacAdam Ellipse Footnotes: 1) Incorporates appropriate dirt depreciation factor for life of luminaire. U.S. and foreign patent(s) issued and pending • 2022 Musco Sports Lighting, LLC • TLC-BT-575 5700K 75 CRI • M-2477-en04-6 Datasheet: Light-Structure System™ www.musco.com · lighting@musco.com 1 TLC-BT-575 5700K 75 CRI Standard System View Datasheet Global M-2477-en04-6 + - Fuse FuseL1 L2* Surge† protection Disconnect Driver Controller(if present) * If L2 is neutral then not switched or fused. † Not present if indoor installation. Luminaire Luminaire and Driver – TLC-BT-575 Typical WiringDriver Data Electrical Data Rated wattage1 Per driver 575 W Per luminaire 575 W Number of luminaires per driver 1 Starting (inrush) current <40 A, 256 µs Fuse rating 15 A UL, IEC ambient temperature rating, electrical components enclosure 50°C (122°F) Ingress protection, electrical components enclosure IP54 Efficiency 95% Total harmonic distortion (THD) at full output <20% 200 Vac 208 Vac 220 Vac 230 Vac 240 Vac 277 Vac 347 Vac 380 Vac 400 Vac 415 Vac 480 Vac 50/60 Hz 60 Hz 50/60 Hz 50 Hz 50/60 Hz 60 Hz 60 Hz 50/60 Hz 50 Hz 50 Hz 60 Hz Max operating current per luminaire2 3.48 A 3.35 A 3.16 A 3.03 A 2.90 A 2.51 A 2.01 A 1.83 A 1.74 A 1.68 A 1.45 A Footnotes: 1) Rated wattage is the power consumption, including driver efficiency losses, at stabilized operation in 25°C ambient temperature environment. 2) Operating current includes allowance for 0.90 minimum power factor, operating temperature, and LED light source manufacturing tolerances. Notes 1. Use thermal magnetic HID-rated or D-curve circuit breakers. 2. See Musco Control System Summary for circuit information. 21.00 in (533 mm) 26.00 in (660 mm) 19.00 in (483 mm) 16.00 in (406 mm) U.S. and foreign patent(s) issued and pending • 2022 Musco Sports Lighting, LLC • TLC-BT-575 5700K 75 CRI • M-2477-en04-6 Datasheet: Light-Structure System™ www.musco.com · lighting@musco.com 2 Luminaire and Driver – TLC-LED-1500 Luminaire Data Weight (luminaire) 67 lb (30 kg) UL listing number E338094 (pending) UL listed for USA/Canada UL1598 CSA-C22.2 No.250.0 (pending) CE Declaration LVD, EMC, RoHS Ingress protection (luminaire)IP65 Impact rating IK07 Material and finish Aluminum, powder-coat painted Wind speed rating (aiming only)150 mi/h (67 m/s) UL, IEC ambient temperature rating (luminaire)50°C (122°F) (pending) Photometric Characteristics Projected lumen maintenance per IES TM-21-11 L90 (20k)>120,000 h L80 (20k)>120,000 h L70 (20k)>120,000 h Lumens1 181,000 CIE correlated color temperature 5700 K Color rendering index (CRI)75 typ, 70 min LED binning tolerance 5-step MacAdam Ellipse Footnotes: 1) Incorporates appropriate dirt depreciation factor for life of luminaire. All components from foundation to poletop are designed to work together in Light-Structure System™ to ensure reliable, trouble-free operation. U.S. and foreign patent(s) issued and pending • ©2023 Musco Sports Lighting, LLC • TLC-LED-1500 5700K 75 CRI Typ • M-2979-en04-5_2023 Datasheet: Light-Structure System™ www.musco.com · lighting@musco.com 1 TLC-LED-1500 5700K 75 CRI Typ System View Datasheet Global M-2979-en04-5_2023 Luminaire and Driver – TLC-LED-1500 Driver Data Electrical Data Rated wattage1 Per driver 1410 W Per luminaire 1410 W Number of luminaires per driver 1 Starting (inrush) current <40 A, 256 µs Fuse rating 15 A UL, IEC ambient temperature rating (electrical components enclosure) 50°C (122°F) (pending) Ingress protection (electrical components enclosure) IP54 Efficiency 95% Dimming mode optional Range, energy consumption 10 – 100% Range, light output 15 – 100% Flicker <2% Total harmonic distortion (THD) at full output <20% (pending) 200 Vac 208 Vac 220 Vac 230 Vac 240 Vac 277 Vac 347 Vac 380 Vac 400 Vac 415 Vac 480 Vac 50/60 Hz 60 Hz 50/60 Hz 50 Hz 50/60 Hz 60 Hz 60 Hz 50/60 Hz 50 Hz 50 Hz 60 Hz Max operating current per luminaire2 8.71 A 8.37 A 7.92 A 7.57 A 7.26 A 6.29 A 5.02 A 4.59 A 4.36 A 4.20 A 3.63 A Footnotes: 1) Rated wattage is the power consumption, including driver efficiency losses, at stabilized operation in 25°C ambient temperature environment. 2) Operating current includes allowance for 0.90 minimum power factor, operating temperature, and LED light source manufacturing tolerances. Notes 1. Use thermal magnetic HID-rated or D-curve circuit breakers. 2. See Musco Control System Summary for circuit information. 22.00 in (559 mm)27.00 in (686 mm) 23.00 in (584 mm) 26.00 in (660 mm) Typical Wiring + - Fuse FuseL1 L2* Surge protection† Disconnect Driver Controller (if present) * If L2 is neutral then not switched or fused.† Not present if indoor installation. Luminaire U.S. and foreign patent(s) issued and pending • ©2023 Musco Sports Lighting, LLC • TLC-LED-1500 5700K 75 CRI Typ • M-2979-en04-5_2023 Datasheet: Light-Structure System™ www.musco.com · lighting@musco.com 2 Datasheet: Smart Lamp® Operating System www.musco.com · lighting@musco.com ©2012, 2022 Musco Sports Lighting, LLC · Smart Lamp® is a registered trademark of Musco Corporation in the United States and Canada. Patents issued and pending. · M-1405-enUS-6 1 Z-Lamp™ Lamp and Ballast — 1000 Watt, 60 Hertz MKT-3064_A Z-Lamp Illustration RWS 26 July 2012 6.25 in (159 mm) 15.38 in (391 mm) Lamp Data Physical Characteristics Lamp type . . . . . . . . . . . . . . . . . .Z-Lamp™ HID quartz metal halide (MH 1000/MZ) Lamp designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .M47 Bulb designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BT-56 Bulb finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Clear Operating position . . . . . . . . . . . . . . . . . . . . . . . .Arc tube horizontal Base . . . . . . . . . . . . . . . . . . . . . . . . . . .Mogul screw position oriented Smart Lamp® Operating System Characteristics¹ Constant lumens² . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88,000 lm Useful lamp life³ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12,000 h CIE correlated color temperature (approximate) . . . . . . . . 4200 K Color rendering index (CRI) . . . . . . . . . . . . . . . . . . . . . . . .Ra = 65 – 70 Warm-up time (80% output) . . . . . . . . . . . . . . . . . . . . . . . . .3 – 5 min CIE chromaticity coordinates (X, Y) . . . . . . . . . . . . . . .(0 .370, 0 .390) Average lamp wattage² . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1040 W Lamp efficacy (100 hrs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112 lm/W Restrike time for hot lamp . . . . . . . . . . . . . . . . . . . . . . . . .10 – 15 min Maximum operating lamp current . . . . . . . . . . . . . . . . . . . . . . .4 .0 A Minimum ambient starting temperature . . . . . . . . .-20 ˚F (-30 ˚C) Footnotes: 1) Photometric and life testing conducted by an ISO 17025 accredited lab (Musco Sports-Lighting Photometry Lab, NVLAP Lab Code 200702-0) . Operating characteristics are per the Musco Smart Lamp® operating system on a commercial ballast with arc tube horizontal . Lamp lumen measurements in accordance with IES LM-51-00 . Lamp color data in accordance with IES LM-58-94 . Lamp operating cycle of five to ten hours per start to reflect expected field use in the sports lighting industry . 2) Lamp starts out at a reduced wattage and increases over life to offset lumen loss as lamp ages . Power dissipated by auxiliary equipment such as ballast, is not included in the lamp wattage shown . 3) Beyond 12,000 hours is the time when constant lumens are no longer maintained by the Smart Lamp operating system . Average rated lamp life before failure is substantially greater than 12,000 hours as tested and defined per IES LM-47-01 with five to ten hours per start . MKT-3064_A Z-Lamp Illustration RWS 26 July 2012 6.25 in (159 mm) 15.38 in (391 mm) Datasheet: Smart Lamp® Operating System 2 www.musco.com · lighting@musco.com ©2012, 2022 Musco Sports Lighting, LLC · Smart Lamp® is a registered trademark of Musco Corporation in the United States and Canada. Patents issued and pending. · M-1405-enUS-6 Z-Lamp™ Lamp and Ballast — 1000 Watt, 60 Hertz Typical Wiring Input voltage/frequency 208 V/60 Hz 240 V/60 Hz 277 V/60 Hz 480 V/60 Hz Maximum operating line current 6 .5 A 5 .8 A 4 .9 A 2 .9 A Starting line current 5 .8 A 5 .3 A 4 .2 A 2 .4 A Fuse rating 20 A 20 A 15 A 15 A Warning These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured . Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used . Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available . This lamp complies with FDA radiation performance standard USA:21CFR 1040 .30 Canada:SOR/DORS/80-381 . Caution Arc tubes of metal halide lamps are designed to operate under high pressure and at temperatures up to 1832 ˚F (1000 ˚C) . If the arc tube ruptures for any reason, pieces of extremely hot glass might be discharged into the surrounding environment, with an associated risk of personal injury, property damage, burns, and fire . To reduce the possibility of arc tube rupture, turn lamps off at least once per week for at least 15 minutes, in systems which are otherwise operating on a continuous basis (24 hours/day, 7 days/week) . Clean exterior luminaire lens when replacing lamp . Hg - LAMP CONTAINS MERCURY Manage in Accord with Disposal Laws See www .lamprecycle .org or call 1-800-825-6020 or +1-641-673-0411 . Ballast Data Physical Characteristics Ballast type . . . . . . . . .Constant Wattage Autotransformer (CWA) Ballast designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .M48 Ballast approvals . . . . . . . . . . . . . . . . . .UL Recognized Component, CSA Certified Electrical Data Power factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97% Line volts regulation* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .± 10% Lamp watts regulation* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .± 10% Nominal input power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1121 W UL insulation class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .N (200 ˚C) UL coil temperature code 1029 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A *Musco requires line voltage within ± 3% to maintain light levels . MKT-2856_A Wiring Schematic For Smart Lamp RWS 27 July 2012 Com Line volts Com Lamp Capacitor Line volts Line volts Line volts Smart Lamp® control Safety: UL Product Certification www.musco.com · lighting@musco.com ©2011, 2017 Musco Sports Lighting, LLC · M-1684-en04-10 UL Product Certification for: Musco Sports Lighting, LLC 100 1st Ave W PO Box 808 Oskaloosa, IA 52577 USA UL Category Covers UL Number High-Intensity Discharge Surface-Mounted Luminaires • Green Generation™ luminaires and remote ballast assemblies • SportsCluster® and SportsCluster-2® luminaires and remote ballast assemblies • Light-Structure 2™ and Light-Structure System™ luminaires and remote ballast assemblies • 1000 W Light-Pak™ and Light-Pak indoor luminaires with Multi-Watt™ control system • 1000 W Show-Light™ and Show-Light Green™ luminaires with hooded light actuator system and remote ballast assemblies • 2000 W Mirtran™ luminaire • Stadium 2K Fixture™ 2000 W luminaire and Hot Restrike Green™ 2000 W hot restrike luminaire E33316 Management Equipment, Energy Lighting control systems for: • Control-Link® control and monitoring system • Control-Link retrofit control system E139944 Industrial Control Panels Control panels and enclosures for: • Control-Link® control and monitoring system • Control-Link retrofit control system • Lighting contactor cabinets • Multi-Watt™ control systems E204954 Emergency Lighting and Power Equipment • Auxiliary Lighting Interface Cabinet (ALIC) E311491 Luminaire Fittings Galvanized steel poles 12 ft (3.7 m) or less for: • Poles for Mirtran™ luminaire mounting • Rooftop poles • Special applications E132445 Luminaire Pole in Excess of 12 ft (3.7 m) Galvanized steel poles greater than 12 ft (3.7 m) for: • Light-Structure System™ luminaire mounting • Sportspole™ structure or mounting system and special applications E325078 Safety: UL Product Certification www.musco.com · lighting@musco.com ©2011, 2017 Musco Sports Lighting, LLC · M-1684-en04-10 UL Category Covers UL Number Devices, Scaffolding Service platforms for: • Light-Structure System™ luminaires and remote ballast assemblies • SportsCluster® System luminaires and remote ballast assemblies SA7004 Lightning Conductors, Air Terminals, and Fittings • Light-Structure System™ pole structure concrete base E337467 Light-Emitting-Diode Surface-Mounted Luminaires • LED luminaires and driver assemblies • LED auxiliary luminaires E338094 A copy of the UL Certificate of Compliance is available upon your request.