Loading...
23-101976-AD-Plan Set-04-13-2023-v1F E D E R A L W A Y M E M O R I A L F I E L D F E D E R A L W A Y P U B L I C S C H O O L S F e d e r a l W a y , W a s h i n g t o n L A N D U S E ORIGINAL SHEET IS 30" x 42" c o p y r i g h t 2 0 2 2 a l l r i g h t s r e s e r v e d s h e e t_ c h e c k e d_ d r a w n_ Project No.m c g - A R C a r c h i t e c t_ MCGRANAHAN ARCHITECTS l o c a t i o n_ c l i e n t_ p r o j e c t_ i s s u e d_ G0.00 COVER SHEET - - 2202.000 s t r u c t u r a l e n g i n e e r _ m e c h a n i c a l e n g i n e e r _ e l e c t r i c a l e n g i n e e r _ l a n d s c a p e a r c h i t e c t _ c i v i l e n g i n e e r _ ETHOS CIVIL AHBL PCS STRUCTURAL SOLUTIONS BCE ENGINEERS BCE ENGINEERS FEDERAL WAY MEMORIAL FIELD FEDERAL WAY PUBLIC SCHOOLS FEDERAL WAY, WA STATE OF WASHINGTON REGISTERED ARCHITECT 8979 KRISTOPHER J. STAMON . r e v i s i o n_ STATE OF WASHINGTON REGISTERED ARCHITECT 8979 KRISTOPHER J. STAMON 67$7(2):$6+,1*721 5(*,67(5(' $5&+,7(&7  .5,6723+(5-67$021 APRIL 13, 2023 - FIELD LIGHTING 13 APR 23LAND USE AMENDMENT 1G0002304005402030 G13200405004020301G10G TTTCCCCCCCCCCCCCCCCCSTAFF PARKINGSTAFF PARKINGSTAFF PARKINGSTAFF PARKINGSTAFF PARKINGSTAFF PARKINGCNO PARKINGVANBUSES ONLYBUSES ONLYBUSES ONLYBUSES ONLYSOUTH 308TH STREETREDEVELOPEDATHLETICFIELD ANDTRACKEXISTING CENTRAL KITCHEN ANDLOCKER ROOMS (BLDG 1)GROSS SF: 32,182 (5,677 ALTERATIONS)CONST TYPE: ASSUMED V-BOCC CLASS: BREDEVELOPED GRAVELPARKING LOTTICKET BOOTH (BLDG 8)GROSS SF: 53CONST TYPE: V-BOCC CLASS: BSTORAGECONTAINERRESTROOMS AND CONCESSIONS (BLDG 2)GROSS SF: 1,751CONST TYPE: V-BOCC CLASS: B & S-214TH AVENUE SOUTH EXISTING TENNIS COURTSEXISTING BASEBALL FIELDSTORMWATERBIORETENTIONFACILITYEASTER LAKE (NOT SURVEYED)LOCATED 160'± SOUTH OFPROJECT PARCEL LINEEXISTINGDETENTIONPOND(EXPANDED)RESTROOMS ANDCONCESSIONS (BLDG 7)GROSS SF: 2,368CONST TYPE: V-BOCC CLASS: B & S-2HOME GRANDSTANDS (BLDG 5)GROSS SF: 11,727CONST TYPE: II-BOCC CLASS: A-5SEATING CAPACITY: 2,000SEATING CAPACITY CHANGE: +680VISITOR GRANDSTANDS (BLDG 6)GROSS SF: 11,719CONST TYPE: II-BOCC CLASS: A-5SEATING CAPACITY: 2,000SEATING CAPACITY CHANGE: +80EXISTING SOFTBALL FIELDEXISTINGTENNISCOURTSEXISTINGMULTI-PURPOSEATHLETIC FIELDEXISTING SHOTPUT FACILITYEXISTING FEDERAL WAYHIGH SCHOOLGROSS SF: 195,139SOUTH 304TH STREETPACIFIC H I G H W A Y S 16TH AVENUE SOUTH14037EXISTING PARKING LOTEXISTINGPARKING LOTPEDESTRIAN PLAZA - HOME (BLDG 3)2,000 SFPEDESTRIAN PLAZA - VISITOR2,000 SF18EXISTING BUS LOOPAND PARKING LOT47326C C C C C C C C C C C C C C C C C C C C C289.0' (EXISTING)95'±95'± TO EXISTING DRIVEWAY ONSOUTH SIDE OF S 308TH STREETFOR LIFE CARE CENTER OFFEDERAL WAY DEVELOPMENT(NOT SURVEYED)EXISTING DRIVEWAYENTRANCE TO REMAINEXISTING DRIVEWAYENTRANCE TO REMAINAPPROX LOCATION OF EXISTINGDRIVEWAY ON SOUTH SIDE OF S308TH STREET FOR CONDOMINIUMDEVELOPMENT (NOT SURVEYED)15' EXISTING LANDSCAPEBUFFER. SEE LANDSCAPEFOR IMPROVEMENTSNEW ACCESSIBLEPATH TO FIELDEV ACCESS ROUTERESTROOMS AND TICKET BOOTH (BLDG 4)GROSS SF: 1,220CONST TYPE: V-BOCC CLASS: B & S-2209'NEARESTSTRUCTUREEXCEEDING 35 FTFIRETRUCKCENTER LINE/LANE LINECCCCCCCCCCCCCCCCCSTAFF PARKINGSTAFF PARKINGSTAFF PARKINGSTAFF PARKINGSTAFF PARKINGSTAFF PARKINGCNO PARKINGVANBUSES ONLYBUSES ONLYBUSES ONLYBUSES ONLYREDEVELOPED GRAVELPARKING LOT289.0' (EXISTING)EXISTING DRIVEWAYENTRANCE TO REMAINCENTER LINE/LANE LINEBUS-45 - Inter City BusBUS-45 - Inter City BusBUS-45 - Inter City BusBUS-45 - Inter City Bus LDJWATORIGINAL SHEET IS 30" x 42"c o p y r i g h t 2 0 2 2a l l r i g h t s r e s e r v e ds h e e t_c h e c k e d_d r a w n_Project No.m c g - A R C a r c h i t e c t_MCGRANAHAN ARCHITECTSl o c a t i o n_c l i e n t_p r o j e c t_i s s u e d_3/22/2022 9:00:12 AM 2202.000s t r u c t u r a l e n g i n e e r _m e c h a n i c a l e n g i n e e r _e l e c t r i c a l e n g i n e e r _l a n d s c a p e a r c h i t e c t _c i v i l e n g i n e e r _ETHOS CIVILAHBLPCS STRUCTURAL SOLUTIONSBCE ENGINEERSBCE ENGINEERSFEDERAL WAY MEMORIAL FIELDFEDERAL WAY PUBLIC SHOOLS1300 S 308th StFEDERAL WAY, WA 98003. r e v i s i o n_Know what'sbelow.before you dig.CallRPERMIT NO UPDATEAPPROVALNOTE: THIS APPROVAL IS VOID 1 (ONE) YEAR AFTER APPROVAL DATE. THECITY WILL NOT BE RESPONSIBLE FOR ERRORS AND/OR OMISSIONS ONTHESE PLANS. FIELD CONDITIONS MAY DICTATE CHANGES TO THESE PLANSAS DETERMINED BY THE CITY ENGINEER.49037NSCALE IN FEET6030060120USE PROCESS III SITEPLANC0.11300 S 308TH STREETFEDERAL WAY, WA 98003SITE ADDRESS OWNER/APPLICANT CIVIL ENGINEER ETHOS CIVIL748 MARKET STREETTACOMA, WA 98402PHONE: 253.365.4973CONTACT: LUCAS JOHNSON, PE LEED APEMAIL: lucas@ethoscivil.comSURVEYOR FEDERAL WAY PUBLIC SCHOOLS33330 8TH AVENUE SFEDERAL WAY, WA 98003PHONE: 206.462.9144CONTACT: TIM AUSINKEMAIL: tausink@fwps.orgLANDSCAPE ARCHITECT AHBL2215 N 30TH STREET - SUITE 300TACOMA, WA 98403PHONE: 253.284.0281CONTACT: DAVID FOLLANSBEE, PLSEMAIL: dfollansbee@ahbl.comBC - COMMUNITY BUSINESSZONING ARCHITECT McGRANAHAN ARCHITECTS2111 PACIFIC AVENUE - SUITE 100TACOMA, WA 98402PHONE: 253.973.6610CONTACT: KRIS STAMON, AIA, DBIAEMAIL: kris.stamon@mcgranahan.comCONTRACTOR BNBUILDERS2601 4TH AVENUE - SUITE 350SEATTLE, WA 98121PHONE: 206.473.2798CONTACT: GERI URBASEMAIL: geri.urbas@bnbuilders.comAHBL2215 N 30TH STREET - SUITE 300TACOMA, WA 98403PHONE: 206.658.2663CONTACT: CRAIG SKIPTON, PLA, LEED APEMAIL: cskipton@ahbl.com38.32± ACRESPARCEL SIZE VICINITY MAP NOT TO SCALENPROJECT SITE0821049001PARCEL NUMBER TREE STANDSTHE PROJECT PARCEL CONTAINS NO STANDS OF TREES ASDEFINED BY FWRC 19.05.200.PHASING AND TIMELINENO PHASING IS PROPOSED. FULL COMPLETION OF PROJECT ISANTICIPATED IN FALL 2023.PARKING SUMMARYPARKING AREASTALLS PROVIDEDSOUTHWEST OF MEM STADIUM140WEST OF FWHS / EAST OF 14TH AVE S (EXIST)37NORTHEAST OF MEM STADIUM (EXIST)18NORTH OF FWHS (EXIST)326BUS LOOP NORTHEAST OF FWHS (EXIST)47*TOTAL568*SURFACE SUMMARYPARCELCONDITIONPERVIOUS AREA(AC)IMPERVIOUS AREA(AC)TOTAL(AC)EXISTING21.8616.6038.46PROPOSED22.0216.4438.46THE EARTHWORK QUANTITIES SHOWN BELOW ARE ESTIMATESONLY. DO NOT USE THEM FOR BIDDING PURPOSES. THEQUANTITIES DO NOT ACCOUNT FOR STRIPPING, COMPACTION,CUT OR FILL ADJUSTMENT FACTORS, PAVEMENT SECTIONS,UTILITY TRENCHING, OR OTHER FACTORS THAT AFFECTEARTHWORK QUANTITIES.CUT:10,000 CYFILL:5,000 CYNET:5,000 CY (CUT)EARTHWORK QUANTITIES NOTE: TABLE ASSUMES SYNTHETIC TURF SURFACES WITH UNDERDRAINSARE PERVIOUS. THIS ASSUMPTION IS NOT APPLIED IN STORMWATERCALCULATIONS.NOTE: BUS LOOP PARKING BACKGROUND DOESNOT MATCH ACTUAL BUILT CONDITIONS. LOTCONTAINS 24 COMPACT AND 23 STANDARDSTALLS (NO ADA)NOTE: THIS AREA IS SUBJECT TO THE CITY OFFEDERAL WAY/FWPS AGREEMENT AND POTENTIALREQUIRED MODIFICATIONS.*16 EXISTING STALLS TO BE IMPACTED BY CURRENT NON-MOTORIZEDVEHICLE PROJECT.EXISTING DRIVEWAYENTRANCE TO REMAINSCHOOL BUS TURNING MOVEMENT NSCALE: 1"=20'NOTE: BUSES WILL NOT EXIT SITE AND TRAVELWEST ON 308TH, NOR WILL THEY APPROACH THESITE ON 308TH FROM THE WEST.SCHOOL BUS INFORMATION FIRETRUCK INFORMATION 12.21.2022FIELD LIGHT POLE F4FIELD LIGHT POLE F2FIELD LIGHT POLE F1FIELD LIGHT POLE F313 APR 23LAND USE AMENDMENT FIELD LIGHTING FIXTURE SCHEDULE DESCRIPTION LAMPS MOUNTING & REMARKS F1 100'-0" POLE HEIGHT. COORDINATE EXACT LIGHT FIXTURE HEADS MOUNTING WITH POLE SUPPLIER AND G.C. PRIOR TO INSTALLATION. F2 F3 F4 REQUIRED MINIMUM MAINTAINED LIGHTING LEVELS : FOOTBALL - AVERAGE F.C. : 50 MIN. MAXIMUM/MINIMUM : 1.31:1 MAX. SOCCER - AVERAGE F.C. : 50 MIN. MAXIMUM/MINIMUM : 1.30:1 MAX. TRACK - AVERAGE F.C. : 26.9 MIN. MAXIMUM/MINIMUM : 13.6:1 MAX. 1 1 1 1 VOLTS / WATTS SYMBOL & POLE DESIGNATION 1 2 100'-0" POLE HEIGHT. COORDINATE EXACT LIGHT FIXTURE HEADS MOUNTING WITH POLE SUPPLIER AND G.C. PRIOR TO INSTALLATION. 100'-0" POLE HEIGHT. COORDINATE EXACT LIGHT FIXTURE HEADS MOUNTING WITH POLE SUPPLIER AND G.C. PRIOR TO INSTALLATION. 100'-0" POLE HEIGHT. COORDINATE EXACT LIGHT FIXTURE HEADS MOUNTING WITH POLE SUPPLIER AND G.C. PRIOR TO INSTALLATION. LED : 1 PHASE, 480V / 14300W LED : 1 PHASE, 480V / 1150W FIELD LIGHTS: (10) LED : 1430W BALL TRACKER LIGHTS: (2) LED : 575W LED : 1 PHASE, 480V / 14300W LED : 1 PHASE, 480V / 1150W FIELD LIGHTS: (10) LED : 1430W BALL TRACKER LIGHTS: (2) LED : 575W LED : 1 PHASE, 480V / 14300W LED : 1 PHASE, 480V / 1150W FIELD LIGHTS: (10) LED : 1430W BALL TRACKER LIGHTS: (2) LED : 575W 2 2 2 2 PROPERTY LINE MAX HORIZONTAL FOOT-CANDLE AT 3'-0" ALONG ENTIRE PROPERTY LINE SHALL NOT EXCEED .01 FOOT-CANDLES. LED : 1 PHASE, 480V / 14300W LED : 1 PHASE, 480V / 1150W FIELD LIGHTS: (10) LED : 1430W BALL TRACKER LIGHTS: (2) LED : 575W FIELD LIGHTING FIXTURE AND POLE #1 FIXTURE AND POLE #2 FIXTURE AND POLE #3 FIXTURE AND POLE #4 3 3 ELECTRICAL CONTRACTOR SHALL COORDINATE ALL WORK WITH FIELD LIGHT FIXTURE SUPPLIER PRIOR TO INSTALLATION. SEE E5.01 FOR FIXTURE AND POLE INSTALLATION, FIXTURE MOUNTING HEIGHTS AND CONTROL DETAILS. PROVIDE QUANTITY OF FIXTURE HEADS AND DRIVERS AS REQUIRED TO PROVIDE MINIMUM MAINTAINED AVERAGE LIGHTING LEVELS OVER ENTIRE DESIGNATED SURFACE. FIELD LIGHTING INCLUDING LIGHT POLES, FIXTURES, AND BASES TO BE SUBMITTED UNDER A SEPARATE PERMIT. FIELD LIGHTING FIELD LIGHTING FIELD LIGHTING CONSTRUCTION NOTES ORIGINAL SHEET IS 30" x 42" c o p y r i g h t 2 0 2 2 a l l r i g h t s r e s e r v e d s h e e t_ c h e c k e d_ d r a w n_ Project No.m c g - A R C l o c a t i o n_ c l i e n t_ p r o j e c t_ i s s u e d_ a r c h i t e c t_ MCGRANAHAN ARCHITECTS E0.04 FIELD LIGHTING FIXTURE & MECHANICAL SCHEDULES BMM OA 2202.000 FEDERAL WAY MEMORIAL FIELD FEDERAL WAY PUBLIC SCHOOLS FEDERAL WAY, WA s t r u c t u r a l e n g i n e e r_ m e c h a n i c a l e n g i n e e r_ e l e c t r i c a l e n g i n e e r_ l a n d s c a p e a r c h i t e c t_ c i v i l e n g i n e e r_ p r e-e n g i n e e r e d s t r u c t u r e s_ ETHOS CIVIL AHBL PCS STRUCTURAL SOLUTIONS BCE ENGINEERS BCE ENGINEERS SOUTHERN BLEACHERS COMPANY . r e v i s i o n_01/17/202313 APR 23LAND USE AMENDMENT W RD WWWWWWWWW WWWWW ><CCCCCCCCCCCCCCCCCSTAFF PARKINGSTAFF PARKINGSTAFF PARKINGSTAFF PARKINGSTAFF PARKINGSTAFF PARKINGNO PARKINGVANC1G0002304005402030 G13200405004020301G10G F2F3AL2AL2HHF4F411E1.33F4F311E1.34J16AL2AL1AL1AAL1AL1AAL1BAL3AL32E1.242E1.34AL1AL1AL1AL1CPOLE MOUNT360°11E1.211E1.31F3F4111HHHHHHT5F3F411AL2B24HH3F3F4F1HHHH1F112111E1.221E1.32HH13G,W6HH24G,WHH1324G,WHHG,W613HHG,WAL2AL28814T65T18HHG,W1F248888888888IDFRACKIDF RACKG,W8815C360°1POLE MOUNTJT1188T7T7T78T7T108861T21T3AL2AL2AAL2AEXISTING UTILITY POLEPRIMARY METER POLEPOINT OF SERVICE78BLDG 1BLDG 7BLDG 6BLDG 2BLDG 4BLDG 3BLDG 5BLDG 8T24F311F413139HV-9HV-10GL-15GL2-7T26LH2-16LH2-16LH2-16888LV-32LV-32LV-32LV-3217171717T3VT17T16F2T19T14T185T4T918T8T8T12T13T9T11419T9T20T152013F12121212122232426r4, r525r3,r426r6,r727r6,r71E1.431E1.441E1.241E1.232E1.441E1.411E1.42C-01C-02POLE MOUNT360°1C-03C2828r4r8r8T22T2113CONSTRUCTION NOTESPROVIDE OLDCASTLE 233-LA HAND HOLE WITH H20 TRAFFIC RATED LID. PROVIDEWEATHER RESISTANT, GFCI TYPE DUPLEX RECEPTACLE TIGHT TO TOP OF HAND HOLEWALL. SEE SHEET 5.02 FOR HANDHOLE DETAILS.EXISTING PRIMARY OVERHEAD POWER.NEW PAD MOUNT TRANSFORMER 'T-FIELD'. SEE ONE LINE DIAGRAM FOR SIZE ANDADDITIONAL INFORMATION.EXISTING PRIMARY POWER HANDHOLE.(1) 1-1/4" CONDUITS FOR LYNX TIMING SYSTEM.INSTALL RECEPTACLE IN FLOORBOX IN HANDHOLE WITHIN TURF AREA. HANDHOLESPECIFIED BY LANDSCAPE, INSTALLED BY TURF OR FIELD SURFACE INSTALLER.COORDINATE EXACT LOCATION PRIOR TO ROUTING CONDUIT.EXISTING SCHOOL DISTRICT OWNED POWER POLE.PROVIDE 1" CONDUIT WITH (2) #10 CU. AND (1) #10 CU. GND.PROVIDE 3030-LA VAULT WITH TRAFFIC RATED LID. ROUTE POWER AND SYSTEMS INSEPARATE CONDUIT AND JUNCTION BOXES.FEEDERS FOR PANELS 'LH2' AND 'GL2' TO SUPPORT RM 402. SEE ONE LINE DIAGRAMON E6.02 FOR CONDUIT AND CONDUCTOR SIZING.FEEDERS FOR PANEL 'HV' TO VISITOR CONCESSION BLDG. SEE ONE LINE DIAGRAM ONE6.02 FOR CONDUIT AND CONDUCTOR SIZING.FEEDERS FOR MAIN DISTRIBUTION BOARD 'MDB' TO SUPPORT RM 202. SEE ONE LINEDIAGRAM ON E6.02 FOR CONDUIT AND CONDUCTOR SIZING.PROVIDE (1) 1" CONDUIT TO HANDHOLE ON FIELD.PROVIDE (2) 1" CONDUIT FOR SCORE BOARD BETWEEN BOOTH 3 AND HANDHOLE .FEEDERS FOR PANEL 'VT' TO BLDG. 8. SEE ONE LINE DIAGRAM ON E6.02 FOR CONDUITAND CONDUCTOR SIZING.FOOD TRUCK POWER CONNECTION. SEE SEE 1.34PROVIDE 1" CONDUIT WITH (2) #6 Cu. AND (1) #10 Cu. GND.PROVIDE (1) 1-1/4" CONDUIT BETWEEN BOOTH 5 AND SUPPORT ROOM 402.PROVIDE CONDUITS BETWEEN BOOTH 3 AND SUPPORT ROOM 402:(1) 1-1/4" (PANEL FEEDER), (2) 1" (GRANDSTAND/FIELD LIGHTING CONTROL), AND(1) 1-/4" (SPARE).PROVIDE (1) 1-1/4" CONDUIT BETWEEN BOOTH 1 AND SUPPORT ROOM 402.MUSCO FIELD LIGHTING AND POLE LOCATION.UNDER BASE BID CONNECT TO EXISTING SCOREBOARD. UNDER ALTERNATE BID #6CONNECT TO NEW SCOREBOARD. COORDINATE WITH GENERAL CONTRACTOR ANDARCHITECT FOR EXACT LOCATION.SEE FLOOR PLAN FOR IRRIGATION CONTROLLER LOCATION. COORDINATE WITHLANDSCAPE AND CIVIL FOR CONDUIT ROUTING.HANDHOLE SUPPLIED BY FIELD TURF/TRACK INSTALLER. EC TO PROVIDE, INSTALL ANDCONNECT DEVICES AND CONDUIT IN HANDHOLE.ROUTE CIRCUITS THROUGH LIGHTING CONTROL PANEL IN BUILDING #2 TO DESIGNATEDCONTROL ZONES AS INDICATED. SEE SHEET E1.32 FOR PANEL GL LOCATION. PROVIDEADDITIONAL CONDUCTORS AS REQUIRED FOR TWO ZONES OF CONTROL TO EACHAL2A AND AL2B FIXTURE.ROUTE CIRCUITS THROUGH LIGHTING CONTROL PANEL IN BUILDING #7 TO DESIGNATEDCONTROL ZONES AS INDICATED. SEE SHEET E1.34 FOR PANEL HV LOCATION. PROVIDEADDITIONAL CONDUCTORS AS REQUIRED FOR TWO ZONES OF CONTROL TO EACH AL1,AL1A, AL1B, AND AL2 FIXTURE.ROUTE CIRCUITS THROUGH LIGHTING CONTROL PANEL IN BUILDING #4 TO DESIGNATEDCONTROL ZONES AS INDICATED. SEE SHEET E1.32 FOR PANEL GL2 LOCATION. PROVIDEADDITIONAL CONDUCTORS AS REQUIRED FOR TWO ZONES OF CONTROL TO EACH AL2FIXTURE.FOR AL3 ONLY PROVIDE ONE ZONE OF CONTROL AND PROVIDE AND EXTEND (2) #14 Cu.,600V CONDUCTORS FOR 0-10V (PURPLE/GREY) DIMMING BETWEENRELAY/CONTROLLER AND EACH FIXTURE DRIVER.1GENERAL NOTES1.SEE ADDITIONAL GENERAL NOTES ON E0.02.2.SEE SHEET E1.34 FOR PANEL 'LV' LOCATION.3.SEE SHEET E1.32 FOR PANEL 'LH2' LOCATION.4.SEE SHEET E5.01 FOR LIGHT POLE BASE DETAILS.2345678910111213141516FIELD LIGHTING CONSTRUCTION NOTESPROVIDE WITH (1) 2"C. WITH·(4) #10 Cu. FOR FIELD LIGHTING FIXTURES 'F1'·(1) #10 Cu. GROUNDING CONDUCTORPROVIDE (2) 1" C.O. SPARES WITH PULL STRINGSPROVIDE WITH (1) 2"C. WITH·(4) #10 Cu. FOR FIELD LIGHTING FIXTURES 'F2'·(1) #10 Cu. GROUNDING CONDUCTORPROVIDE (2) 1" C.O. SPARES WITH PULL STRINGSPROVIDE WITH (1) 2"C. WITH·(4) #6 Cu. FOR FIELD LIGHTING FIXTURES 'F3'·(1) #6 Cu. GROUNDING CONDUCTORPROVIDE (2) 1" C.O. SPARES WITH PULL STRINGSPROVIDE WITH (1) 2"C. WITH·(4) #4 Cu. FOR FIELD LIGHTING FIXTURES 'F4'·(1) #4 Cu. GROUNDING CONDUCTORPROVIDE (2) 1" C.O. SPARES WITH PULL STRINGSF11718192021F2F3F4222324252627TELECOM CONSTRUCTION NOTESPROVIDE (2) CAT6 OSP / WET-RATED CABLES BETWEEN PRESSBOX 501 AND THEHAND HOLE SHOWN NEXT TO THE FINISH LINE. TERMINATE ON BOTH ENDS, TESTAND LABEL AS LYNX-1 AND LYNX-2. USE THE PROVIDED DATA ROUGH-INLOCATIONS PROVIDED IN THE PRE-MANUFACTURED BOOTH ON THE NORTHWALL. PROVIDE WEATHERPROOF WHILE-IN-USE HANDHOLE.PROVIDE (2) 1" CONDUITS BETWEEN HAND HOLE AND A JUNCTION BOX IN THENORTH EAST CEILING SPACE OF STORAGE 102A IN BUILDING 1 (SCOREBOARD &SPARE/DATA).(4) 1-1/4" CONDUITS TO VISITOR CONCESSION BLDG. (DATA, SECURITY, FIREALARM, AND SPARE). IDF EAST TO IDF WEST. PROVIDE 3-CELL MAXCELLINNERDUCT IN DATA 1-1/4" CONDUIT. PROVIDE (1) 6-STRAND OM3 MMINDOOR/OUTDOOR FIBER AND (1) CAT6 OSP BACKBONE.(2) 1" CONDUITS TO HANDHOLE ON FIELD (DATA & SCOREBOARD).PROVIDE LOW-VOLTAGE HAND HOLE. PROVIDE OLDCASTLE 233-LA HAND HOLEWITH H20 TRAFFIC RATED LID.(1) 1-1/4" CONDUITS TO SCORE BOARD (DATA & SCOREBOARD).(1) 1-1/4" CONDUIT TO PARKING LOT POLE MOUNT CAMERA FROM WEST IDF.UTILIZE SUPERIOR ESSEX POWERWISE CAT6 (WET RATED) OR EQUAL FOR RUNSOVER 90 METERS THAT ARE WARRANTIED BY LEVITON CABLE SYSTEM.(2) 2" CONDUITS FROM AV RACK TO VISITORS GRANDSTAND VIA SOUTHHANDHOLE AND GUEST CONCESSIONS (BLDG 7).(3) 1" CONDUITS BETWEEN GUEST CONCESSIONS (BLDG 7) SUPPORT ROOM ANDACCESSIBLE CEILING OF GUEST TICKET BOOTH (BLDG 8).(1) 2" CONDUIT FROM GUEST CONCESSIONS (BLDG 7) SUPPORT ROOM/IDF TOFIELD LIGHT POLE. COORDINATE WITH OWNER'S VENDOR (DISTRICT RADIO) FORINSTALLATION OF CABLE AND ANTENNA HEIGHT ON POLE.PROVIDE LOW VOLTAGE JUNCTION/PULL BOX - SIZE AS REQUIRED ANDCOORDINATE EXACT LOCATION. SEE SHEET E1.43 FOR CONTINUATION TODEVICES MOUNTED ON STAND.(3) 2" CONDUIT FROM SUPPORT ROOM/IDF TO GUEST BLEACHER JUNCTION BOX.PROVIDE CONDUITS BETWEEN ACCESSIBLE CEILINGS OF BOOTH 5 AND BOOTH 1:(1) 1-1/4" (DATA), (1) 1" (SECURITY), (1) 1" (FIRE ALARM), AND (1) 1-1/4" (SPARE).PROVIDE CONDUITS BETWEEN ACCESSIBLE CEILINGS AR BOOTH 5 AND BOOTH 3:(2) 2" (DATA), (1) 1" (SECURITY), (1) 1" (FIRE ALARM) AND (1) 1-1/4" SPARE.PROVIDE CONDUITS BETWEEN ACCESSIBLE CEILING OF BOOTH 5 AND BLDG 2SUPPORT ROOM 202:(1) 2" DATA, (1) 1-1/4" (SECURITY), (1) 1" (FIRE ALARM), AND (2) 1" SPARE.PROVIDE CONDUITS BETWEEN ACCESSIBLE CEILING OF BOOTH 5 AND BLDG 4SUPPORT ROOM 402:(1) 2" (DATA), (1) 1-1/4" (SECURITY), (1) 1-1/4" (FIRE ALARM), (2) 1" (SPARE).PROVIDE (1) 2" CONDUIT FROM ACCESSIBLE CEILING OF BOOTH 1 TO TRACKTIMING HANDHOLE VIA VAULT.PROVIDE CONDUITS FROM AV RACK IN BOOTH 3 TO THE ACCESSIBLE CEILING OFBOOTH 1:(1) 1-1/4" AND (1) 3/4" (AUDIO/VIDEO).PROVIDE CONDUITS FROM AV RACK IN BOOTH 3 TO THE ACCESSIBLE CEILING OFBOOTH 5:(1) 1-1/4" AND (2) 3/4 " (AUDIO/VIDEO).PROVIDE (1) 1" CONDUIT BETWEEN HAND HOLES FOR LOW VOLTAGE CABLING BYOTHERS FOR PORTABLE PLAY CLOCK TIMERS.PROVIDE (1) 1" CONDUIT BETWEEN HAND HOLE AND SUPPORT ROOM/IDF FORLOW VOLTAGE CABLING BY OTHERS FOR PORTABLE PLAY CLOCK TIMERS.T1T2T3T4T5T6T7T8T9T10T11T12T13T14T15T16T17T18T19T2028T21T22ORIGINAL SHEET IS 30" x 42"c o p y r i g h t 2 0 2 2a l l r i g h t s r e s e r v e d40'20'040'80'SCALE: 1"=40'-0"PROJECTNORTH 1" = 40'-0"ELECTRICAL SITE PLANs h e e t_c h e c k e d_d r a w n_Project No.m c g - A R C a r c h i t e c t_MCGRANAHAN ARCHITECTSl o c a t i o n_c l i e n t_p r o j e c t_i s s u e d_2202.000s t r u c t u r a l e n g i n e e r_m e c h a n i c a l e n g i n e e r_e l e c t r i c a l e n g i n e e r_l a n d s c a p e a r c h i t e c t_c i v i l e n g i n e e r_p r e-e n g i n e e r e d s t r u c t u r e s_ETHOS CIVILAHBLPCS STRUCTURAL SOLUTIONSBCE ENGINEERSBCE ENGINEERSSOUTHERN BLEACHERS COMPANYFEDERAL WAY MEMORIAL FIELDFEDERAL WAY PUBLIC SCHOOLSFEDERAL WAY, WAPERMIT REVISION15 NOV 22. r e v i s i o n_E1.01ELECTRICAL SITEPLANBMMOAs h e e t_c h e c k e d_d r a w n_Project No.m c g - A R C l o c a t i o n_c l i e n t_p r o j e c t_i s s u e d_a r c h i t e c t_MCGRANAHAN ARCHITECTSE1.01ELECTRICAL SITEPLANCheckerAuthor2202.000FEDERAL WAY MEMORIAL FIELDFEDERAL WAY PUBLIC SCHOOLSFEDERAL WAY, WAPERMIT REVISION 12 JAN 23s t r u c t u r a l e n g i n e e r_m e c h a n i c a l e n g i n e e r_e l e c t r i c a l e n g i n e e r_l a n d s c a p e a r c h i t e c t_c i v i l e n g i n e e r_p r e-e n g i n e e r e d s t r u c t u r e s_ETHOS CIVILAHBLPCS STRUCTURAL SOLUTIONSBCE ENGINEERSBCE ENGINEERSSOUTHERN BLEACHERS COMPANY. r e v i s i o n_01/17/2023CONSTRUCTION SET13 APR 23LAND USE AMENDMENT PARKING LOT CALCULATIONS PLAN E1.02 12/10/ 2 0 21 4/7/2 0 2 2 4/21/ 2 0 2 2 12/10/ 2 0 21 4/6/2 0 2 2 4/7/2 0 2 2 4/21/ 2 2 4/26/ 2 2 /10/20 2 /6/202 2 4/7/2 0 2 2 4/26/ 2 2 5/10/2022 AL1 13 APR 23LAND USE AMENDMENT