03-104777PROJECT INFORMATION 0 w N C3 c 0 .0 0 0. E 0 0 0 0< 0 w IL w 0. z Jai n u. z v to IId] 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR — GENERAL CONTRACTOR (CONSTRUCTION) OWNER — AT&T WIRELESS SERVICES. 2. ALL SITE WORK SHALL BE COMPLETED AS INDICATED ON THE DRAWINGS AND PROJECT SPECIFICATIONS. 3. DRAWINGS PROVIDED HERE ARE NOT TO BE SCALED AND ARE INTENDED TO SHOW OUTLINE ONLY. 4. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. 5. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 6. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 7. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 8. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY THE CONTRACTOR. 9. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 10. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 11. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY ENGINEERS. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING & EXCAVATION. 12. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, AS DIRECTED BY THE RESPONSIBLE ENGINEER, AND SUBJECT TO THE APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES. 13. THE AREAS OF THE OWNER'S PROPERTY DISTURBED BY THE WORK ;\f,!D NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION. 14, CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. 15. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 16. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 17. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE BTS EQUIPMENT AND TOWER AREAS. 18. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY, I19. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE. i C20. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. FROM SEATAC AIRPORT Bear RIGHT (South) onto SR-99 [International Blvd] Turn LEFT (East) onto S 200th St Bear RIGHT (South —East) onto Ramp Merge onto 1--5 (South)At 1-5 Exit 142B, turn off onto Romp Merge onto SR-18 [S 348th St] (West) Turn LEFT (South) onto SR-161 [Enchanted Pky S] Bear LEFT (East) onto S 356th St Arrive 1741 S 356th St, Federal Way, WA 98003 0 SCOPE OF WORK: UNMANNED TELECOMMUNICATIONS FACILITY MODIFICATIONS SITE ADDRESS: 1741 S 356TH AVE FEDERAL WAY, WA 98003 LATITUDE: 47' 16' 56" N NAD 1983 LONGITUDE: 122' 18'40" W JURISDICTION: CITY OF FEDERAL WAY CURRENT USE: TELECOMMUNICATIONS FACILITY PROPOSED USE: TELECOMMUNICATIONS FACILITY ZONING: COMMUNITY BUSINESS (CB) AP NUMBER: 282104 9178 06 PROJECT AREA: 25 SQ FT OWNER: RUSSEL R. LLOYD PO BOX 4203 FEDERAL WAY, WA 98063 (253) 804-5709 CONTACT: PTS 425 PONTIUS AVE N SEATTLE, WA 98109 ALEX PERLMAN (206) 612-1563 489 24897-612-HOO-STTLWASS70-AO1 SITE PLAN 4a> i,• O—AO1.1 .. t ENLARGED 4897— - H O Ar 0—A01.2 ELEVATIONS ., r � 9 OO1 L � O ANTENNACONFIGURATION 24897-612-HOO-STTLWASS70-AO4 NOTES 24897-612-HOO-STTLWASS70-AOS DETAILS 24897-612-HOO-STTLWASS70-AO6 NOTES AND DETAILS 24897-612-HOO-STTLWASS70-EO3 POWER AND GROUNDING SCHEMATIC 1 nchanted Ak . A& 0ww&T A I AT&T WIRELESS SERVICES, INC. 2729 PROPECT PARK DRIVE RANCHO CORDOVA. CA 95670 98 Exit 142A ... I'll 30 Flb;1 .:< .. BUILDING CODE: WASHINGTON BUILDING CODE 1997 ALL WORK IS TO COMPLY WITH THE WASHINGTON STATE BUILDING CODE, AMENDMENTS AND STANDARDS, WAC 51-40 (EFFECTIVE JULY 1, 2003) INCLUDING THE FOLLOWING CODES IN ORDER OF PRECEDENCE PER WASHINGTON STATE BLDG. CODE ACT CHAPTER 19.27 RCW. THE 1997: UNIFORM BLDG CODE STANDARDS AND AMENDMENTS —WAC 51-40; UNIFORM MECHANICAL CODE STANDARDS AND AMENDMENTS—WAC 51--42; UNIFORM FIRE CODE STANDARDS AND AMENDMENTS—WAC 51 —44, 51-45; UNIFORM PLUMBING CODE, STANDARDS, AND AMENDMENTS —WAC 51-56, 51-57. WHERE THERE IS A CONFLICT BETWEEN CODES, AN EARLIER NAMED CODE TAKES PRECEDENCE OF A LATER NAMED CODE. IN THE CASE OF CONFLICT BETWEEN — WAC 51-40 CHAP. 12 ONLY AND WASHINGTON STATE VENTILATION AND INDOOR c!R QUALITY CODE— WAC 51-13 —WAC— 51-13 TAKES IN THE CASE OF CONFLICT BETWEEN WASHINGTON STATE ENERGY CODE—WAC 51-1 1 AND THE UNIFORM MECHANICAL CODE—WAC 51 —42, ONLY IN THE CASE OF DUCT INSULATION REQUIREMENTS THE WASHINGTON STATE ENERGY CODE SHALL APPLY. IN ANY SPECIFIC CASE ON CONFLICTS BETWEEN SECTIONS OF ANY CODE REGUARDING MATERIALS, METHODS OF CONSTRUCT101"l, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHA!-L GOVERN. CONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN. CONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING STANDARDS. AMERICAN CONCRETE INSTITUTE (ACI) 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, ASD, NINTH EDITION TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 222—F, STRUCTURAL STANDARD FOR STRUCTURAL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING EARTH RESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND SYSTEM IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OF ELECTRONIC EQUIPMENT IEEE C62.41, RECOMMENDED PRACTICES ON SURGE VOLTAGES IN LOW VOLTAGE AC POWER CIRCUITS (FOR LOCATION CATEGORY "(1-3" AND "HIGH SYSTEM EXPOSURE") TIA 607 COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS TELCORDIA GR-63 NETWORK EQUIPMENT —BUILDING SYSTEM (NEBS): PHYSICAL" PROTECTION TELCORDIA GR-347 CENTRAL OFFICE POWER WIRING TELCORDIA GR-1275 GENERAL INSTALLATION REQUIREMENTS TELCORDIA GR--1503 COAXIAL CABLE CONNECTIONS'=> FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING -MATERIAL;:, METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE REQUIREMENT SHALL. GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND "A SPCIF'I REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN. 6019 IST IZEi) AT&T WIRELESS T 0 10/01/03 ISSUED FOR CD REVIEW LCN JMG EjC TITLE SHEET A 09/26/03 ISSUED FOR CD REVIEW LCN JMG EJC A ' STA E SHI GTON NO. DATE REVISIONS BY CHK JAPRV JOB NWISER ORAMIC NUMKR KV TM E: AS SHOWN DESIGNED BY-. DRAWN By: 24897-612 lHoo—sTrLwAsS70—T01 0 3 2 1 N RECEIVED, OCT 2 0 2003 ,t CtTY0F FEDERAL WAY BUILDING DEPT. L LEGAL DESCRIPTION THE LAND REFERRED TO IN THIS COMMITMENT IS SITUTATED IN THE COUNTY OF KING, STATE OF WASHINGTON, AND DESCRIBED AS FOLLOWS: THAT PORTION OF THE SOUTHWEST OF THE NORTHWEST QUARTER OF SECTION 28, TOWNSHIP 21 NORTH, RANGE 4 EAST, IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: BEGINNING AT THE NORTHWEST CORNER OF SAID SUBDIVISION; THENCE NORTH 89'36'00" EAST ALONG THE NORTH LINE THEREOF 181.58 FEET TO A POINT OF THE EASTERLY MARGIN OF STATE HIGHWAY NO. 5-D AN THE TRUE POINT OF BEGINNING OF THIS DESCRIPTION; THENCE NORTH 89'36'00" EAST 275 FEET TO A POINT HEREAFTER REFERRED TO AS POINT "A"; THENCE NORTH 89'36'00" EAST 201.31 FEET; THENCE SOUTH 0'09'00" WEST 255 FEET; THENCE SOUTH 89'36'00" WEST 201 FEET, MORE OR LESS, TO A POINT WHICH BEARS SOUTH 924'00" EAST FROM POINT "A"; THENCE NORTH 0'24'00" WEST 225 FEET, MORE OR LESS, TO THE SOUTH LINE OF THE NORTH 30 FEET OF SAID SUBDIVISION; THENCE SOUTH 89' 36'00" WEST TO THE EASTERLY MARGIN OF SAID STATE HIGHWAY NO. 5-0; THENCE NORTHERLY ALONG SAID EASTERLY MARGIN TO THE TRUE POINT OF BEGINNING. LOCATION OF [E] LOCATION OF [E]UTILITY POLE UTILITY POLE W/ AND TELCO TRANSFORMER PEDISTAL E E—E—E—E E -•--•-- E —• E — E — E — £ — E — £ — E ^-^ E -^- E • -- E — E ••---�--• E £ — E — E --•—^ E — E — E ^— E — E — E — £ — E— E — E — E — E — E — E — £ ^^-^— E •-•— E --- E — £ — E'�•-- £ ^^-- E •-- £ --�---•- E --- E -- E — E — E — E — E -^ E — E -- E — E — E E E--E— E— £ — E -� I r m EXfSTlN -- ELECTRICAL ,, m HAND HOLD ] x x� m � it I r I x� I mm I x xl m ol e mm 1 r x ! mm C� x [E] N mm VQICESTREAM xj I EQUIPMENT I I r I PROPOSE[ [E] CINGULAR XENT — — PROJECT WIDE E o0ll AREA° 1 o01 SEE A01.1 I ° r y....... 1 1 :x 0 x� r � r ,x 1\\--,E] BUILDING i y I x [E] GRAVEL 4 � i 04 0 1 i � O I I ♦ / Z�/ L _ Q �COOoc�OocOC>C S L.: E SITE PLAN SCALE: 1 "=40'-O" ENCHANTED PARKWAY STTLW 1741 S 356TH AVE FEDERAL WAY, WA 98003 5 4 GRAPHIC SCALE ( IN FEET ) 1 inch = 40 ft. mom A% AT&T AT&T WIRELESS SERVICES, INC. 2729 PROPECT PARK DRIVE RANCHO CORDOVA, CA 95670 N, 10 156'46* ZONING NOTES 1. NO PARKING STALLS ARE AFFECTED BY THIS INSTALLATION. . 2. EROSION CONTROL TO BE MAINTAINED THROUGHOUT CONSTRUCTION PHASE. 3. EQUIPMENT CABINETS ARE LOCKED, SELFCONTAINED AND ACCESSIBLE TO AUTHORIZED AT&T PERSONNEL ONLY. 4. PROVIDE SIGNAGE AT EQUIPMENT READING AS FOLLOWS: "RADIO -FREQUENCY EQUIPMENT IN USE AT SITE. IN CASE OF EMERGENCY, PLEASE CALL 1-800-387-7647. 1. THIS PROPOSAL IS FOR AN UNMANNED TELECOMMUNICATIONS FACILITY CONSISTING OF ANTENNAS AND SUPPORTING EQUIPMENT CABINETS. i 2. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE. 3, THE PROPOSED FACILITY IS UNMANNED AND IS NOT FOR HUMAN HABITAT. (NO HANDICAP ACCESS IS REQUIRED). 4, OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2 TIMES PER MONTH, BY AT&T TECHNICIANS. 5, NO NOISE, SMOKE, DUST OR ODOR WILL RESULT FROM THIS PROPOSAL. s, OUTDOOR STORAGE AND SOLID WASTE CONTAINERS ARE NOT PROPOSED. 7. ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE APPLICABLE SECTIONS OF SPECIFICATION NUMBER 24897-01 1--3PS-AOOZ--G0001."TECHINCAL SPECIFICATION FOR CONSTRUCTION OF GSM/GPRS WIRELESS SITES," AND 24897-011--3PS--EGOO--G0001, "TECHNICAL SPECIFICATION FOR FACILITY GROUNDING". IN CASE OF A CONFLICT BETWEEN THC CONSTRUCTION SPECIFICATION AND THE DRAWINGS THE DRAWINGS SHALL GOVERN. 8, CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY THE CONSTRUCTION OPERATION. 99. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTION REQUIRED FOR CONSTRUCTION. 10. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. 11. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND DRAWINGS PROVIDED BY THE SITE OWNER. SUBCONTRACTOR SHALL NOTIFY AT&T OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 12. NO WHITE STROBIC LIGHTS ARE PERMITTED, LIGHTING, IF REQUIRED, WILL MEET FAA STANDARDS AND REQUIREMENTS. 13. CONTRACTOR SHALL CALL MISS UTILITY FOR UNDERGROUND UTILITY MARKOUT PRIOR TO CONSTRUCTION. 1-800-PER DIG NOTE. 4. ALL SIGNS SHALL BE FURNISHED AND INSTALLED AT ALL AT&T WIRELESS SERVICES (AWS) SITES IN ACCORDANCE WITH SPECIFICATION 24897-01 1-3PS-AOOOZ-00006. NST RED AT&T WIRELESS 0 10/01/03 ISSUED FOR CD REVIEW LCN JMG EJC T SITE PLAN A 09/26/03 ISSUED 14. DATE FOR CD REVIEW REVISIONS LCN JMG EJC BY GHK APRY 0 F. I STfi E t• Stile GTON JOB NUMBER DRAWMG NUMBER REV CAE: AS SHM IDESIGNED BY: ®RAWN BY: 24897-612 IHOO—STTLWASS70—AO1 0 2 � RECEIVED L�J 101 9 ■r u OCT 2 0 2003 CITY OF FEDERAL WAY BUILDING DEPT. EQUIPMENT LEGEND U1 FIRE EXTINGUISHER O FIRE SUPRESSION/HALON O FIRE SUPRESSION/FM 200 U4 EMERGENCY LIGHTS O FIRST AID KIT �6 EMERGENCY EYE AND SKIN WASH STATION O7 BATTERIES/GEL CELL AMP/HR O8 BATTERY DISCONNECT AMP O9 24VDC POWER BOARD AMP 10 48VDC POWER BOARD AMP 11 DC TO DC CONVERTER 12 INVERTER 1 AMP 13 INVERTER 2 AMP 14 COMMERCIAL AC METER 15 ELECTRICAL SERVICE ENTRANCE PANEL 200 AMP 16 COMMERCIAL AC SERVICE DISCONNECT 17 AC TRANSFORMER KVA 18 COMMERCIAL AC LOAD CENTER AMP 19 AC MAIN BREAKER PANEL POSITION 20 AC SURGE SUPRESSOR PRI SEC 21 TRANSFER SWITCH/MANUAL �2 TRANSFER SWITCH/AUTOMATIC 2� PORTABLE GENERATOR PLUG �4 STANDBY GENERATOR KW 2�5 AC LEG BOOSTER (S) 26 EXTERNAL SECURITY LIGHTING TOWER OBSTRUCTION LIGHTING CONTROL BOX �8 GFCI OUTLET �9 HVAC UNIT 30 THERMOSTAT/HVAC CONTROLS 31 HUMIDIFIER 3� DE HUMIDIFIER (ROOM) 33 DE HUMIDIFIER. (COAX/WAVEGUIDE) 34 SUMP PUMP 35 CABLE ENTRANCE PANEL (CEILING) 36 QUARTER WAVE STUB (QWS) 3� TELCO BOARD: X 38 TELCO GROUND BAR: X 39 MASTER GROUND BAR (MGB): X 40 POWER PLANT RETURN BAR: X 41 NIU (S) 4� CSU (S) 43 PHONE (POTS) 44 66 BLOCK 45 DSX PANEL POS, 46 MDF 4�7 ALARM DEMARCATION 48 NEW NORTEL UMTS iBTS EQUIPMENT O x w �1 x ol W ox x O 1 O{xI W 1 0- EXISTING BOLLARDS r x (TYP.) E x AY x- x i x-- x- xl r x l I W NEW TRANS UP " TO ICEBRIDE 001 x s AOa x � O 1 EXISTING 10'-6"x6'-0" T EQUIPMENT SLAB x ` � EXISTING 6'-0" HIGH CHAIN LINK xj B FENCE O ) (TYP) NEW AT&T UMTS I OUTDOOR 4$ EXISTING UTILITY CABINET x EQUIPMENT RACK NEW CABLE TRAY 2 x SCALE: 1 /2"= V-0" Q01 x AO6 -- x- x- x x T x-� 6" s xp 4 Q 32$ NEW AT&T U.G. O 6 -0 ., I . I x � AO3 POWER/TELCO i ROUTE TO RACK j E] BUILDING GENERAL NOTES FOR EXISTING AWS BASE STATION SITES 1. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CONTRACTOR. 2. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS MUST BE VERIFIED. CONTRACTOR SHALL NOTIFY THE CONTRACTOR OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 3. THE EXISTING CELL SITE IS IN FULL COMMERCIAL OPERATION. ANY CONSTRUCTION WORK BY CONTRACTOR SHALL NOT DISRUPT THE EXISTING NORMAL OPERATION. ANY WORK ON EXISTING EQUIPMENT MUST BE COORDINATED WITH CONTRACTOR. ALSO, WORK SHOULD BE SCHEDULED FOR AN APPROPRIATE MAINTENANCE WINDOW USUALLY IN LOW TRAFFIC PERIODS AFTER MIDNIGHT. 4. SINCE THE CELL SITE IS ACTIVE, ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN WORKING AROUND HIGH LEVELS OF ELECTROMAGNETIC RADIATION. EQUIPMENT SHOULD BE SHUTDOWN PRIOR TO PERFORMING ANY WORK THAT COULD EXPOSE THE WORKERS TO DANGER. PERSONAL RF EXPOSURE MONITORS ARE ADVISED TO BE WORN TO ALERT OF ANY DANGEROUS EXPOSURE LEVELS. 5. CONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWING. CONTRACTOR SHALL UTILIZE EXISTING TRAYS AND/OR SHALL ADD NEW TRAYS AS NECESSARY. CONTRACTOR SHALL CONFIRM THE ACTUAL ROUTING WITH THE CONTRACTOR. 6, CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. DETAIL 300A NTS 5 ENCHANTED PARKWAY STTLWASS7 1741 S 356TH AVE FEDERAL WAY, WA 98003 0 EXISTING AT&T UTILITY RACK EXISTING AT&T EQUIPMENT EXISTING ICEBRIDGE x NEW UMTS AT&T ANTENNA NEW AT&T TWR FRAME L- x -x r , 1 ENLARGED SITE PLAN EXIST. EQUIP. PROPOSED EQUIP. � FUTURE EQUIP. ............ EXIST. CABLE TRAY CONDUCTORS AND RACEWAY TO BE FURNISHED & INSTALLED BY CONTRACTOR 0 10/01/03 ISSUED FOR CD REVIEW A 09/26/03 ISSUED FOR CD REVIEW 10. DATE REVIS*NS SCALE: AS SHEriYN DESIGNED BY: m Eo r 00 W) x 4 AOFP1 LCN JRAG EJCLCN JMG EJC STA BY I CHdt ARRV DRAWN Bar. 2 GRAPHIC SCALE Q 2 4 6 16 ( IN FEET ) 1 inch = 4 ft. EXISTING CINGULAR EQUIPMENT CABINETS EXISTING LANDSCAPE EXISTING ICE BRIDGE •-- EXISTING AT&T ANTENNA TO BE RELOCATED TO NEW TWR FRAME (TYP OF 2) ANTENNA NOTE: -] EXISTING ANTENNAS NOT SHOWN FOR CLARITY NEW AT&T TWR FRAME A06 NEW AT&T UMTS fl04 ANTENNA AO6 EXISTING NEXTEL EQUIPMENT CABINETS EXISTING LANDSCAPING TO REMAIN EXISTING SPRINT EQUIPMENT CABINETS Q1 NORTEL UMTS iBTS OUTDOOR CABINET CABLE COVER EQUIPMENT DETAIL NTS AT&T WIRELESS ENLARGED SITE PLAN AND NOTES As NUMBER NG NUMBER 24897-61 FHOO--STTLWASS70--AO1.1 o 1 101 14 6 U RECEIVED OCT 2 0 2003 CITY OF FEDERAL WAY BUILDING DEPT. N 4 `I I I 4630 200TH STREET SW, SUITE K LYNNWOOD, WA 96036 PHONE: (425) 670-6651 FAX: 712-0646 (425) Architects - Engineers, P.C. 6 (D_EAST ELEVATION SCALE: 1/8" = 1'—a" L ENCHANTED PARKWAY STTL 1741 S 358TH AVE FEDERAL WAY, WA 98003 M AT&T WIRELESS SERVICES, INC. 2729 PROPECT PARK DRNE RANCHO CORDOVA. CA 95670 3 1 SOUTH ELEVATION SCALE: 1/8" = 1'-0" 0 10/01 /03 ISSUED FOR CD REVIEW LCN JMG EJC A 09/26/03 ISSUED FOR CD REVIEW LCN JMG EJC N0. DATE REVISIONS BY 041C APRV GALE: AS S140WN DESIGNED BY: DRAWN BY: 2 roof AT&T WIFELESS ELEVATIONS Jm IARI WR DRAONG t#JM R REV 24897-812 ---][H00--STTLINASS70--AOt.2 0 1 I N 9 0 RECEIVED OCT 2 0 2003 CITYOF FEDERAL WAY BUILDING DEFT, RF NOTES: 1. QUANTITIES SHOWN IN ( ) ARE TOTAL QUANTITY. NOTE: 1. LEAN CONCRETE w/ RED TINTED TOP MAY BE USED IN PLACE OF COMPACTED SAND. 2. ACTUAL LENGTHS SHALL BE DETERMINED PER SITE CONDITION BY CONTRACTOR. 3. THE DESIGN IS BASED ON RF DATA SHEETS, SIGNED AND APPROVED. 4. RADIO SIGNAL CABLE AND RACEWAY SHALL COMPLY WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NEC, NFPA 70), CHAPTER 8. 5. ALL SPECIFIED MATERIAL FOR EACH LOCATION (E.G., OUTDOORS, INDOORS -OCCUPIED, INDOORS -UNOCCUPIED, PLENUMS, RISER SHAFTS, ETC.) SHALL BE APPROVED, LISTED, OR LABELED AS REQUIRED BY THE NEC. 6. RADIO SIGNAL CABLE SHALL BE SUPPORTED AT MINIMUM OF EVERY THREE (3) FEET EXCEPT INSIDE MONOPOLES OR LATTICE TOWERS WHERE CABLE AND CONNECTOR MANUFACTURERS SUPPORT RECOMMENDATIONS SHALL BE FOLLOWED. MANUFACTURER RECOMMENDED CABLE SUPPORT ACCESSORIES SHALL BE USED. 7. THE OUTDOOR CABLE SUPPORT SYSTEM SHALL BE PROVIDED WITH AN ICE SHIELD TO SUPPORT AND PROTECT ANTENNA CABLE RUNS. SEE DETAIL NUMBER 576. 8. DRIP LOOPS SHALL BE REQUIRED ON ALL OUTSIDE CABLES. CABLES SHALL BE SLOPED AWAY FROM THE BUILDING OR OUTDOOR BTS CABINETS TO PREVENT WATER FROM ENTERING THROUGH THE COAXIAL CABLE PORT. 9. ALL FEEDER LINE AND JUMPER CONNECTORS FOR GSM SHALL BE AWS APPROVED 7--16 DIN CABLE CONNECTORS THAT MEET IP68 STANDARDS. 10. WHEN MODIFYING EXISTING TDMA COAXIAL CABLES FOR GSM USE, REMOVE ALL EXISTING N TYPE CONNECTORS WHERE FEASIBLE AND REPLACE WITH NEW 7-16 DIN CONNECTORS. 11. MINIMUM CABLE BENDING RADIUS SHALL BE ADHERED TO IN ACCORDANCE WITH SECTION 6.0 OF DESIGN CRITERIA (DOCUMENT NO. 24623-033-3DR-GET-00001). 12. ALL 7-16 DIN CONNECTORS SHALL BE IP68 RATED. ALL OUTDOOR CONNECTORS AND ALL COAXIAL CABLE SHIELDING GROUND POINTS SHALL BE WEATHERPROOFED IN ACCORDANCE WITH THE FOLLOWING PROCEDURE: START WITH ANDREW WEATHERPROOFING KIT TYPE 221213. START TAPE APPROXIMATELY 5 INCHES FROM THE CONNECTOR AND WRAP 2 INCHES TOWARD THE CONNECTOR, THEN REVERSE THE TAPE SO THAT THE STICKY SIDE IS UP. TAPE OVER THE CONNECTOR OR SURGE ARRESTOR UNTIL THREE (3) TO FOUR (4) INCHES BEYOND THE CONNECTOR AND REVERSE AGAIN WITH THE STICKY SIDE DOWN FOR ANOTHER INCH OR TWO. ADD THE BUTYL RUBBER AND FINISH WITH A FINAL LAYER OF ANDREWS TAPE. 13, MHA's/TMA's SHALL NOT BE PAINTED. 14, ANTENNAS SHALL BE PAINTED, WHEN REQUIRED, TO MATCH EXISTING ANTENNAS IN ACCORDANCE WITH ANTENNA MANUFACTURERS' SURFACE PREPARATION AND PAINTING REQUIREMENTS. ALLGON ANTENNAS SHALL USE ALLGON SYSTEM AB; ALLGON DOCUMENT NUMBER 990323/LI_. KATHREIN TECHNICAL BULLETIN # 1 19 OCT. 99. 15. CABLE SHIELDS, AND TOWER CONDUITS SHALL BE GROUNDED AT THE TOP OF THE TOWER, WITHIN 10 FEET OF THEIR CONNECTORS, AND AT THE BOTTOM OF THE TOWER ABOUT 6 INCHES BEFORE THEY TURN TOWARD THE FACILITY. THEY SHALL BE GROUNDED AT THE MIDPOINT OF TOWERS THAT ARE BETWEEN 150 FEET AND 300 FEET HIGH, AND AT INTERVALS OF 150 FEET OR LESS ON TOWERS THAT ARE HIGHER THAN 300 FEET. THEY SHALL BE ALSO GROUNDED AT THE WAVEGUIDE ENTRANCE TO THE FACILITY. 16. APPROVED GROUNDING KITS, WHICH INCLUDE GROUNDING STRAPS, SHALL BE USED TO GROUND THE COAXIAL CABLE SHIELDS, AND CONDUITS. THE GROUND CONDUCTORS FOR THE KITS AT THE TOP OF THE TOWER, AND IN THE MIDDLE SECTION OF THE TOWER, ARE BONDED DIRECTLY TO TOWER STEEL USING EXOTHERMIC, BOLTED, OR APPROVED CLAMP CONNECTIONS, 17, ALL RADIO SIGNAL CABLE SHALL BE LABELED WITH COLOR -CODED ELECTRICAL TAPE (3M SCOTCH 35, 7 MILS THICK, % INCH WIDE, VINYL ELECTRICAL TAPE, OR CONTRACTOR APPROVED EQUAL) AND BRASS OR STAINLESS STEEL IDENTIFICATION TAGS AS SPECIFIED IN DETAIL NUMBER 600, 600A. 18. THE CONTRACTOR SHALL FILL IN DETAIL 601 AND AFFIX IT TO A WEATHER -PROTECTED LOCATION (E.G., THE SHELTER INTERIOR WALL) NEAR THE CABLE PORT. 19, RECOMMENDED SURGE ARRESTORS THAT CAN BE USED WITH THE BTS EQUIPMENT: ANDREW: 7-16 DIN M/F WIDEBAND 1 /4 WAVE, GAS TUBE WITH DC BYPASS HUBER+SUHNER: 7-16 DIN M/F WIDEBAND 1 /4 WAVE, GAS TUBE WITH DC BYPASS 20. DUPLEXERS AND/OR DIPLEXERS AND MOUNTING HARDWARE (J CLAMPS) WHERE REQUIRED SHALL BE SUPPLIED BY CONTRACTOR AND INSTALLED BY THE CONTRACTOR. 21. MHA/TMA'S TO BE INSTALLED AT TOWER TOP, SHALL BE SUPPLIED BY CONTRACTOR (WHERE REQUIRED) AND INSTALLED BY THE CONTRACTOR. 22. ANTENNA FEED LINE SYSTEM SWEEP TESTING SHALL BE PERFORMED AND REPORTED IN ACCORDANCE WITH THE REQUIREMENTS OF AWS DOCUMENT NO. WNS-0284 (LATEST REVISION). CONTRACTOR WILL NOT ACCEPT A RADIO SIGNAL CABLE INSTALLATION WITH UNSATISFACTORY SWEEP TEST RESULTS. DETAIL r520 0 ENCHANTED PARKWAY STTLWASS7 1741 S 356TH AVE FEDERAL WAY, WA 98003 AT&T WIRELESS SERVICES, INC. 2729 PROPECT PARK DRIVE RANCHO CORDOVA, CA 95670 FINISHED GRADE OR GROUND COVER, MATCH SLOPE AND THICKNESS OF EXISTING UNDISTURBED SOIL 1 36" CONDUITS FOR -` TELEPHONE, ELECTRICAL, & ANTENNA SHARING WHERE APPLICABLE * TRENCH CAUTIONARY .4 � `TAPE =+ - COMPACTED BACKFILL If{-.jI��II IIII IIII� W/ SATISFACTORY NATIVE OR IMPORTED -TI=1I SOIL III-Ii COMPACTED SAND i=l�I (SEE NOTE 1) IYI III I II MIT IITpE COMPACTED SAND BED III III Illlfkl� f�f_Il�lfl I (SEE NOTE 1) 3"" MIN (TYP)_ 6" (MIN) * CONDUIT SIZE, TYPE, QUANTITY AND SEPARATION DIMENSION TO BE VERIFIED WITH LOCAL UTILITY COMPANY REQUIREMENTS U.G. POWER AND TELCO COUNDUITS (328 CONCRETE AND REINFORCING STEEL NOTES: 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI 336, ASTM A184, ASTM A185 AND THE DESIGN AND CONSTRUCTION SPECIFICATION FOR CAST -IN -PLACE CONCRETE. 2. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI AT 28 DAYS, UNLESS NOTED OTHERWISE. 3. REINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE 60, DEFORMED UNLESS NOTED OTHERWISE. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185 WELDED STEEL WIRE FABRIC UNLESS NOTED OTHERWISE. SPLICES SHALL BE CLASS "B" AND ALL HOOKS SHALL BE STANDARD, UNO. 4. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: CONCRETE CAST AGAINST EARTH ........ 3 IN. CONCRETE EXPOSED TO EARTH OR WEATHER: #6 AND LARGER ...................2 IN. 5 AND SMALLER & WWF ........1 1 /2 IN. CONCRETE NOT EXPOSED TO EARTH OR WEATHER OR NOT CAST AGAINST THE GROUND: SLAB AND WALL ........................3/4 IN. BEAMS AND COLUMNS...............1 1 /2 IN. 5. A CHAMFER 3/4" SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNO, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. 6. INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR, SHALL BE PER MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURE. THE ANCHOR BOLT, DOWEL OR ROD SHALL CONFORM TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. NO REBAR SHALL BE CUT WITHOUT PRIOR ENGINEERING APPROVAL WHEN DRILLING HOLES IN CONCRETE. EXPANSION BOLTS SHALL BE PROVIDED BY RAMSET/REDHEAD OR APPROVED EQUAL, UNLESS NOTED OTHERWISE. SPECIAL INSPECTIONS, WHEN REQUIRED BY GOVERNING CODES, SHALL BE PERFORMED IN ORDER TO MAINTAIN MANUFACTURER'S MAXIMUM ALLOWABLE LOADS. CONCRETE AND REINFORCING STEEL NOTES 302 © 10/01 /03 ISSUED FOR CD REVIEW LCN JMG EJC A 09/26/03 ISSUED FOR CD REVIEW LCN JMG EJC NO. I DATE REVISIONS BY CHK APRV GALE: AS SHOWN DESIGNED BY: IDRAWNBY: 60 A IL STITERWASHl&NGTO AT&T WIRELESS RF NOTES AND DETAILS im IMUMKR o vow. Nu R 24897-612 HOO-STTLWASS70-AO3 109 0 `t l OCT 2 0 2003 CITY OF FEDERAL WAY BUILDING DEPT. Q1 1. WIRING, RACEWAY, AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC AND TELCORDIA. 2. CONTRACTOR SHALL MODIFY EXISTING CABLE TRAY SYSTEM AS REQUIRED TO SUPPORT RF AND TRANSPORT CABLING TO THE NEW BTS EQUIPMENT. 3, ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MAXIMUM CABLE SEPARATION AS REQUIRED BY THE NEC AND TELCORDIA. 4. CABLES SHALL NOT BE ROUTED THROUGH LADDER -STYLE CABLE TRAY RUNGS. 5. EACH END OF EVERY POWER, GROUNDING, AND T1 CONDUCTOR AND CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1 /2 INCH PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC & OSHA, AND MATCH EXISTING INSTALLATION REQUIREMENTS. 6. POWER PHASE CONDUCTORS (I.E. HOTS) SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, % INCH PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). PHASE CONDUCTOR COLOR CODES SHALL CONFORM WITH THE NEC & OSHA AND MATCH EXISTING INSTALLATION REQUIREMENTS. 7. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. ALL EQUIPMENT SHALL BE LABELED WITH THEIR VOLTAGE RATING, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING, AND BRANCH CIRCUIT ID NUMBERS (I.E., PANELBOARD AND CIRCUIT ID'S). 8. PANELBOARDS (ID NUMBERS) AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS) SHALL BE CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. 9. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. GROUNDING NOTES 23. CABINETS, BOXES, AND WIREWAYS SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN 1, THE CONTRACTOR SHALL REVIEW AND INSPECT THE EXISTING FACILITY GROUNDING SYSTEM AND LIGHTNING ACCORDANCE WITH NEMA, UL, ANSI/IEEE, AND NEC. PROTECTION SYSTEM (AS DESIGNED AND INSTALLED) FOR STRICT COMPLIANCE WITH THE NEC (AS ADOPTED BY THE AHJ), THE SITE -SPECIFIC (UL, LPI, OR NFPA) LIGHTING PROTECTION CODE, AND GENERAL COMPLIANCE 24, CABINETS, BOXES, AND WIREWAYS TO MATCH THE EXISTING INSTALLATION WHERE POSSIBLE. WITH TELCORDIA AND TIA GROUNDING STANDARDS. THE CONTRACTOR SHALL REPORT ANY VIOLATIONS OR 25. WIREWAYS SHALL BE EPDXY -COATED (GRAY) AND INCLUDE A HINGED COVER, DESIGNED TO SWING ADVERSE FINDINGS TO THE CONTRACTOR FOR RESOLUTION. OPEN DOWNWARD; SHALL BE PANDUIT TYPE E (OR EQUAL); AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA 3R (OR BETTER) OUTDOORS. 2. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION, AND AC POWER GES'S) SHALL BE BONDED TOGETHER, AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING 26. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES, AND PULL BOXES SHALL BE GALVANIZED CONDUCTORS IN ACCORDANCE WITH THE NEC. OR EPDXY -COATED SHEET STEEL, SHALL MEET OR EXCEED UL 50, AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA 3R (OR BETTER) OUTDOORS 3. THE CONTRACTOR SHALL PERFORM IEEE FALL -OF -POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 27. METAL RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED, OR NON- AND 81) FOR NEW GROUND ELECTRODE SYSTEMS. THE CONTRACTOR SHALL FURNISH AND INSTALL CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1; AND RATED NEMA 1 (OR BETTER) SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. 4. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED 28, NONMETALLIC RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; AND COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED RATED NEMA 1 (OR BETTER) INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 10. POWER, CONTROL, AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR (#14 AWG AND LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90° WC (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED. 11. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE CONDUCTOR (#6 AWG AND LARGER), 600 V, OIL RESISTANT THHN OR THWN-2 GREEN INSULATION, CLASS B STRANDED COPPER CABLE RATED FOR 90° WC (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED. 12. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED OUTDOORS, OR BELOW GRADE, SHALL BE SINGLE CONDUCTOR #2 AWG SOLID TINNED COPPER CABLE. 13. POWER AND CONTROL WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI -CONDUCTOR, TYPE TC CABLE (# 14 AWG AND LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90° WC (WET AND DRY) OPERATION; WITH OUTER JACKET; LISTED OR LABELED FOR THE LOCATION USED. 14. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND IRENUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRENUTS SHALL BE RATED FOR OPERATION AT NO LESS THAN 75' WC (90' WC IF AVAILABLE). 15. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE, AND NEC. 16. NEW RACEWAY OR CABLE TRAY WILL MATCH THE EXISTING INSTALLATION WHERE POSSIBLE. 17. ELECTRICAL METALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40, OR RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO PHYSICAL DAMAGE) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 18. ELECTRICAL METALLIC TUBING (EMT), ELECTRICAL NONMETALLIC TUBING (ENT), OR RIGID NONMETALLIC CONDUIT (RIGID PVC, SCHEDULE 40) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 19. GALVANIZED STEEL INTERMEDIATE METALLIC CONDUIT (IMC) SHALL BE USED FOR OUTDOOR LOCATIONS ABOVE GRADE. 20. RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40 OR RIGID PVC SCHEDULE 80) SHALL BE USED UNDERGROUND; DIRECT BURIED, IN AREAS OF OCCASIONAL LIGHT VEHICLE TRAFFIC OR ENCASED IN REINFORCED CONCRETE IN AREAS OF HEAVY VEHICLE TRAFFIC. 21. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID -TITS FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 22. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SETSCREW FITTINGS ARE NOT ACCEPTABLE. DETAIL 512 29. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CONTRACTOR 5. EACH INDOOR BTS CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 AWG OR LARGER. 30. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD 6. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. AGAINST LIFE AND PROPERTY. 31. ALL OUTDOOR HARDWARE SHALL BE HOT DIP GALVANIZED OR STAINLESS STEEL, SUCH AS CHANNEL STRUT, CLAMPS, SCREWS, BOLTS, ANCHORS, STRAPS. NO ZINC PLATED MATERIALS. TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) 1. TVSS DEVICES FOR AC POWER SHALL BE INSTALLED IN ALL EXISTING FACILITIES THAT ARE MISSING TVSS DEVICES OR HAVE UNSUITABLE TVSS DEVICES. 2. SURGE SUPPRESSION AND PROTECTION DEVICES SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NEC) ART 250, 280, AND CHAPTER 8, AS APPLICABLE. 3. EACH EXISTING AC POWER SERVICE DISCONNECT SHALL HAVE AN INTEGRATED COMMON MODE TVSS MODULE. THE TVSS MODULE SHALL BE EITHER CUTLER -HAMMER, CLIPPER POWER SYSTEM, MODEL CPS-SX, 120 KA (WITH THE BASIC DIAGNOSTIC PACKAGE AND FORM-C ALARM CONTACTS) OR (FOR AWS SITES WITHOUT THE INTEGRATED CUTLER -HAMMER PANELBOARD) INNOVATIVE TECHNOLOGIES MODEL PTX-160-1 S101 FOR SINGLE PHASE OR PTX160-3Y101 FOR 3-PHASE (OR OWNER APPROVED EQUAL). 4. THE AC POWER COMMON MODE SURGE SUPPRESSOR SHALL BE CONNECTED TO THE COMMERCIAL POWER INPUT SIDE OF THE MANUAL TRANSFER SWITCH, 5. IN MARKETS WITH LIGHTNING ZONE > OR = TO 4, RF TVSS DEVICE SHALL BE INSTALLED AT THE ENTRANCE TO THE SHELTER OR AS CLOSE AS POSSIBLE TO THE BTS CABINET FOR OUTDOOR SITES TO PROTECT AGAINST LIGHTNING AND TRANSIT VOLTAGES. THE RF TVSS DEVICES SHALL BE D.C. PASSING, 1 /4 WAVE GAS TUBE WITH 7-16 DIN CONNECTORS. 6. SEE DETAILS 520 AND 527 FOR ADDITIONAL RF COAXIAL TVSS REQUIREMENTS. 7. A T1 TRANSPORT TVSS DEVICE SHALL BE INSTALLED AT ALL SITES BETWEEN THE NIU AND THE BTS. THE T1 TVSS SHALL BE ATLANTIC SCIENTIFIC MODEL NO. 90700 WITH 5" DIN RAIL #21605 FOR UP TO 4 TVSS MODULES. ENCHANTED PARKWAY STTLWAS '70 1741 S 356TH AVE FEDERAL WAY, WA 98003 N DETAIL (506 AT&T WIRELESS SERVICES, INC. 2729 PROPECT PARK DRNE RANCHO CORDOVA, CA 95670 7• APPROVED ANTIOXIDANT COATINGS (I.E., CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 8• ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 9 SURFACES TO BE CONNECTED TO GROUND CONDUCTORS SHALL BE CLEANED TO A BRIGHT SURFACE AT ALL CONNECTIONS. 10. EXPOSED GROUNDING CONNECTIONS SHALL BE MADE WITH COMPRESSION CONNECTORS WHICH ARE THEN BOLTED TO EQUIPMENT USING STAINLESS STEEL HARDWARE. INSTALLATION TORQUE SHALL BE PER MANUFACTURE'S REQUIREMENT. 11. ALL OUTDOOR METAL SUPPORT POSTS FOR ICE BRIDGE AND TRAY SHALL BE BONDED TO THE EXISTING BURIEI GROUND ELECTRODE SYSTEM WITH A SINGLE CONDUCTOR #2 AWG SOLID TINNED COPPER WIRE. DETAIL 511 SYMBOLS ABBREVIATIONS AGL ABOVE GRADE LEVEL S/G SOLID GROUND BUS BAR AWG AMERICAN WIRE GAUGE BCW BARE COPPER WIRE S/N SOLID NEUTRAL BUS BAR BTS BASE TRANSCEIVER SCE ER STATION 00 2-POLE THERMAL -MAGNETIC (E) EXISTING CIRCUIT BREAKER 0 0 EG EQUIPMENT GROUND SINGLE -POLE THERMAL -MAGNETIC EGR EXTERNAL GROUND RING CIRCUIT BREAKER EMT ELECTRICAL METALLIC TUBING ® GROUND ROD WITH ACCESS GEN GENERATOR ® CHEMICAL GROUND ROD IGR INTERNAL GROUND RING (HALO) GROUND ROD IMC INTERMEDIATE METALLIC CONDUIT [� DISCONNECT SWITCH MGB MASTER GROUND BAR Rl METER MIN MINIMUM CIRCUIT BREAKER NTS NOT TO SCALE PVC RIGID (SCH. 40) POLYVINYL CHLORIDE CONDUIT ® CADWELD TYPE CONNECTION REF REFERENCE COMPRESSION TYPE CONNECTION REQ REQUIRED GROUNDING WIRE RF RADIO FREQUENCY REPRESENTS DETAIL NUMBER RGS RIGID GALVANIZED STEEL XXX -4•---REFERENCE SHEET NUMBER RWY RACEWAY TBD TO BE DETERMINED TBR TO BE RESOLVED TYP TYPICAL ELECTRICAL ABBREVIATIONS & SYMBOLS (500_� 6019 AT&T WIRELESS ERED 0 10/01 /03 ISSUED FOR CD REVIEW LCN JMG EJC NOTES A 09/26/03 ISSUED FOR CD REVIEW LCN JMG EJC 'STATA tiFW�slllr�Nra�t� 10. DATE REMSOIS BY CHK APRgi JOB NUMBER ORA"NG NUMBER CALE: AS SHOWN DESIGNED BY: DRAMPN BY: 24897-612 H00-STTLWASS70-A04 RECEIVED [7 111 14 0 OCT 2 0 2003 CITY OF FEDERAL WAY BUILDING DEPT. NOTE: 1. DRAWING SCHEMATIC ONLY TYPICAL OF EACH ANTENNA, VERIFY WITH FINAL RF DATA SHEET. cs a 0 0) 0 0 c� L_ e 0 04 O c 0 w c E 0 a a� w 2. CONTRACTOR TO VERIFY NEED FOR DUPLEXER/DIPLEXER AND VERIFY WITH FINAL RF DATA SHEET PRIOR TO INSTALL (SHOWN ON SCHEMATIC FOR INFORMATION ONLY). 3. CONTRACTOR TO VERIFY NEED FOR TMAS AND VERIFY WITH FINAL RF DATA SHEET PRIOR TO INSTALL (SHOWN ON SCHEMATIC FOR INFORMATION ONLY). SECTOR ANTENNA (TYP) u MAIN COAX (TYP BULKHEAD LQUME DIPLEXER OR DUPLEXER OR RF COUPLERS (AS NEEDED VERIFY W/ RF) TMA (AS NEEDED VERIFY WITH RF) 2 JUMPER CABLE (TYP) MALE (TYP) k--o_81 FEMALE (TYP) BTS EQUIPMENT TYPICAL ANTENNA CABLE MARKING TAGS ALL RF CABLE SHALL BE MARKED AS PER CABLE MARKING LOCATIONS TABLE BELOW: CABLE MARKING LOCATIONS N0. TAPE TAG LOCATIONS 1. X X BEFORE ANTENNA 2. X AFTER TMA (AS NEEDED) 3. X BEFORE TMA (AS NEEDED) 4. X X END OF MAIN COAX 5, X X INSIDE OF BULKHEAD 6. X AFTER DUPLEXER (AS NEEDED) 7. X X BEFORE DUPLEXER (AS NEEDED) 8. LX X S AT BTS DETAIL 600A SECTOR C GAMMA 18 1-6 5 1 2 3 4 6 SECTOR B BETA 13-18 12 11 SECTOR C ALPHA 7-12 NOTE: VERIFY FINAL SITE CONFIGURATION WITH RF DATA SHEET/ ENGINEER. ANTENNA SECTOR AND CABLE DEFINITION CABLE MARKING COLOR CONVENTION TABLE CABLE CABLE CABLE CABLE CABLE CABLE SECTOR Al A2 A3 A4 A5 A6 ONE TWO THREE FOUR FIVE SIX ALPHA, A, X RED RED RED RED RED RED CABLE CABLE CABLE CABLE CABLE CABLE SECTOR B B1 B2 B3 B4 B5 B6 BETA, B, Y ONE TWO THREE FOUR FIVE Six BLUE BLUE BLUE BLUE BLUE BLUE CABLE CABLE CABLE CABLE CABLE CABLE SECTOR C1 C2 C3 C4 C5 C6 ONE TWO THREE FOUR FIVE Six GAMMA, C, Z GREEN GREEN GREEN GREEN GREEN GREEN CABLE CABLE CABLE CABLE CABLE CABLE SECTOR D1 D2 D3 D4 D5 D6 ONE ;; TWO THREE FOUR FIVE SIX DELTA, D, W YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW NOTE: 1. USING COLOR BANDS ON THE CABLES, MARK ALL RF CABLE BY SECTOR AND CABLE NUMBER AS SHOWN ON "CABLE MARKING COLOR CONVENTION TABLE" (EXAMPLE SECTOR ALPHA, CABLE A3 WOULD BE THREE RED BANDS). 2. THE STANDARD CABLE MARKING TAPE IS BASED ON THE "4 NEMA" COLORED TAPES — RED, BLUE, GREEN AND YELLOW. 3. ON EXISTING SITE THE COLOR CODING SHALL FOLLOW THE EXISTING MARKET COLOR CODING. 4. IN THE ABSENCE OF AN EXISTING COLOR CODING AND TAGGING SCHEME, OR WHEN INSTALLING NEW COAXIAL CABLES, THIS GUIDELINE IS TO BE IMPLEMENTED AT THE SITE REGARDLESS OF TECHNOLOGY. NOTE: IF THERE IS NO EXISTING COLOR CODING REFER TO WNS-217 Sector Cable UMTS 1 LINE BRASS TAG ENCHANTED PARKWAY STTLWASS70 1741 S 356TH AVE FEDERAL WAY, WA 98003 0 U MTS —. EQUIP. CABINET CONC. SLAB AT&T WIRELESS SERVICES, INC. 2729 PROPECT PARK DRIVE RANCHO CORDOVA. CA 95670 4 X 4 (6'-0" MAX. SPACING) PROVIDE (2) #2 BTCW TO GROUND RING 1'-0" (MAX) FROM END OF MAIN COAX JUMPER CABLE ENTERS AT SIDE OF EQUIPMENT GRIP STRUT 11 3/4"W x 1-1 /2"D 5 DIAMOND PLANK, TYP. OF (2) COAX LADDER FROM CABLE TRAY TO ICEBRIDGE LADDER TYPE CABLE TRAY W/ COVER FIN. GRADE 41 * 6" MIN. BELOW FROST LINE COAX CABLE TRAY TO ICEBRIDGE DETAIL 001 0 10/01 /03 ISSUED FOR CD REVIEW LCN JMG EJC A 09/26/03 ISSUED FOR CD REVIEW LCN JMG EJC N0. DATE REVISIONS BY CHK APRV SCALE: AS SHOWN DESIGNED BY: JORAWNBY: 0019 T IL L A td STATE OF IBASHINGTGN 2 3/8" 0 O.D. G.I. PIPE 5/8" 0 U— BOLT COAXIAL CABLE PER PLAN EXISTING ICEBRIDGE 9" 0 CONCRETE PIER AT&T WIRELESS DETAILS JOB NUMBER DRAWING NUMBER IREVI 24897- 612 H00--STTLWASS70-A05 0 RECEIVED O C T 2 0 2003 bify.01= FEDERAL WA,*f E U]LDiNG DEPT. 0 I. NOTE: COAX LADDER TOWER LEG 721 CABLE TRAY COVERS SHALL BE INSTALLED IN ACCORDANCE WITH MAIN COAX CABLE ALMODEL: — MANUFACTURER'S INSTALLATION PROCEDURES AND INSTRUCTIONS FOR (BENDING RADIUS AS PER (UXM-1710710-2170-65181—A) 'HIGH WIND CONDITIONS'. THIS INCLUDES CONNECTOR TYPE AND MANUFACTURER'S STANDARDS) SPACINGS. HEIGHT 1309 MM (51.5") 4 X 4 (6'-0" WIDTH 167 MM (6.6") [BECHTEL PN CC30001 — 12" WIDE MAX. SPACING) COAX GROUND KIT89.5 _ SEE DETAIL 575/E01 DEPTHW M OR CC30002 6 WIDE] CABLE TRAY ANTENNA WEIGHT 65 KG(114.3 LBS ) COVER (SEE NOTE) 8 ATTACHED WEIGHT W/ TILT 10.1 KG (22.2 LBS) [BECHTEL PN CT20002 --- 12" WIDE PROVIDE (2) #2 BTCW T W L11 /41 GA V. BOLTS OR CT20001 - 6" WIDE] CABLE TRAY, GROUND RING GALV. STEEL, 12" RUNGS, 4" LOADING DEPTH, 5" SIDE RAIL HEIGHT, WIDTH LADDER TYPE CABLE TOWER AS SHOWN IN PLAN 1'-O" (MAX) FROM TRAY W/ COVER FRAMING END OF MAIN COAX STAKE 4x4 WITH 12" GALVANIZED UMTS SPIKE OR #4 EPDXY COATED REBAR. EQUIP. ANTENNA DETAIL 004 I CABINET INSTALL FLUSH WITH TOP OF 4x4 um FIN. GRADE [BECHTEL PN CT2 0013] 4x4 /\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\ \\\\ \ PRESSURE TREATED LUMBER �� ��\/\/ /\/\�\///\//\/�\�\�\//\//\// /�/\//\//\// ///\�\//\//\//\�\/ \//\//�//\//\//\//\///\ \//` �\ ,\\ \\ \\/\\/\\/\\/\\/\\/\\/\\/\\\\/\\/\\�\\/ j\\j\\j\\j\\j\\j\\j\\j / / / //\\/\\/ \\// /\//\///\//\//\//\//\//\//\//\//\//\ HOLD DOWN CLAMP /\/\/ /\/\/\/\/\/\/\/\/\/\/\/\/\ \/ FASTENED TO 4 X 4 /\\//\\//\\\\\\\\\\\\\\\\\\\\\\/\\ JUMPER CABLE ENTERS WITH 1 j4" x 1 1 /4" AT SIDE OF EQUIPMENT LONG LAG SCREWS (TYP.) CONC. SLAB MAX SPACING 6'-0" BETWEEN SUPPORTS COAX CABLE TRAY OUTDOOR CABINETS DETAIL 600'1� NTS — NORTEL UMTS OUTDOOR DIMENSIONS CABINET HEIGHT x WIDTH x DEPTH OUTDOOR 51.18"x53.15"x27.56"x27.56"/37.4" (1300mm x 1350mm x 700/950mm*) * DEPTH -- WITH CABLE COVER 5 4 5 4 0." OPTIONAL DOWNTILT ° BRACKET ., 3 ANTENNA MOUTING PIPE (TYP.) as as PANEL ANTENNA PREFERRED STABILIZING AVROD ATTACHMENT (TYF') `-- 1 PIPE MOUNT (TYP) VALMONT MICROFLECT PART #131001 OR APPROVED EQUAL 0 4 1 /2" OD PIPE & E ANGLE CLAMP KIT PARTS: 0 EXISTING ANGLE 0 ALTCRNATE LEG TOWER NOTES ANTENNA STABLIZING ) 1 INSERT SCISSOR BRACKETS BETWEEN THE UPPER ANTENNA ITEM QTY DESCRIPTION ROD ATTACHMENT MOUNTING BRACKET AND THE UPPER POLE ADAPTER BRACKET. 1 1 ADAPTER, POLE, LOWER SECURE USING 1 /2 INCH HARDWARE PROVIDED. 1 BRACKET, DOWNTILT, POLE 2). TO SET THE DEGREE OF DOWNTILT, ALIGN THE DESIRED HOLES 30 1 BRACKET, DOWNTILT, ANTENNA ON THE SCISSOR BRACKETS AND SECURE USING 5/16 INCH HARDWARE PROVIDED. ® 4 1/2 X 1 HEX HEAD BOLT NORTEL UMTS OUTDOOR WEIGHT & SLAB LOADING CABINET APPROX. MAX. WEIGHT MAX. SLAB LOADING OUTDOOR UMTS BTS (WORST CASE) 1,050 LBS (477 KG) 1,229 LBS/FT 2 (600 KG/M 2) NORTEL OUTDOOR MINIMUM CLEARANCES DIRECTION MINIMUM CLEARANCE CABINET REAR 7.87" AND WALL (200 mm) CABINET RIGHT/LEFT SIDE 11.81 " AND WALL (300mm) ABOVE THE 1 1.81 " CABINET (300mm) IN FRONT OF THE 51.18" CABINET 1300mm Q 3). THE NUMBER OF CONNECTORS WILL VARY BASED ON 4 1/2 SPUIT WASHER ANTENNA TYPE. © 2 5/16 X 1 HEX HEAD BOLT CL rx TOWER I= RAMS DETAIL 002 C� 2 5/16 SPLIT WASHER � DETAIL 1251 ANTENNA MOUNTING DETAIL 003 NTs a A z W v ® ,sIzI�ls AT&T WIRELESS ENCHANTED PARKWAYT i.CN JMG EJC I 4630 200TH STREET SVIt, SUITE K ' NOTES AND DETAILS � LYNNWoo®, WA 98036 STTL1it/A �7 0 10/0�/©3 Issue=0 FOR ca R�nEvu PHONE: (425) 670-8651 1741 S 356TH AVE A 09/26/03 ISSUED FOR CD REVIEW LCN .)MG Edc STt? E ' " m AT&T WIRELESS SERVICES, INC. AT'�`A$ I�GTOId MENI I FAX: (425) 712-0846 FEDERAL WAY, WA 98003 2729 PROPECT PARK DRIVE NO• DATE REVISIONS ByCHK APRY JOB NtWIER DRAB as Ias RANCHO CORDOVA, CA 95670 E: AS SHOWN Arch6tects - Eng9neers, R.C. DESIGNED BY: IDRAWN BY.. 24897— f 12 H00--STTLWASS70--AO6 0 6 5 4 3 2 1 RECEIVED OCT 2 0 2003 01TY OF FEDERAL. WAY BUILDING DEPT. 5 4 2 4 6 2„ 3/a o ° 0J 0 0 0 p� a 00 0 0 a� a T a a 0 0 ' 3 0 0 0 1 SEE DETAIL 508A 0 a 1 LEGEND 1-- COPPER GROUND BAR, %a x 4"x 20", NEWTON INSTRUMENT CO. CAT. NO. B-6142 OR EQUAL. HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION. (ACTUAL GROUND BAR SIZE WILL VARY BASED ON NUMBER OF GROUND CONNECTIONS) 2— INSULATORS, NEWTON INSTRUMENT CAT. NO. 3061-4 OR EQUAL 3— 5/8" LOCK WASHERS, NEWTON INSTRUMENT CO. CAT. NO. 3015-8 OR EQUAL 4— WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. CAT NO. A-6056 OR EQUAL 5— 5/8-1 1 X 1" HHCS BOLTS, NEWTON INSTRUMENT CO. CAT NO. 3012-1 OR EQUAL 6— INSULATORS SHALL BE ELIMINATED WHEN BONDING DIRECTLY TO TOWER/MONOPOLE STRUCTURE. CONNECTION TO TOWER/MONOPOLE STRUCTURE SHALL BE PER MANUFACTURERS RECOMMENDATIONS. GROUND BAR DETAIL DETAIL (509 NTS TO LOW NOISE AMPLIFIER TO TRANSMIT UNITS (LNA) (WHEN ANTENNA REQUIRED) AND RECEIVE ANTENNA 1_TX RX1/RX2 RX1/RX2 ANTENNA GROUND TO ANTENNA BAR W/O INSULATORS BONDED DIRECTLY TO GROUND KIT (TYP) THE TOP OF TOWER. WEATHERPROOFING KIT SEE NOTE 1 & DETAIL 508A (TYP.} #6 AWG (PROVIDED CABLE TO ANTENNA WITH GROUNDING _ STANDARD GROUND KIT KIT TYP) (TYP.) (SEE NOTE) S 4 STRANDED CU WIRE WITH GREEN, COAX CABLE 600V, THHN/THWN INSULATION. ANTENNA GROUND BAR (TYP FOR ALL) SIZE AS SPECIFIED W/O INSULATORS, BONDED DIRECTLY TO THE BOTTOM OF TOWER SEE NOTE 1. SEE DETAIL 508A GROUND KIT (TYP.) ANTENNA CABLE CONNECTOR TO BTS (TYP.) r EXOTHERMIC WELD WEATHERPROOFING KIT (TYP.) L GROUND BAR ON #2 AWG BCW TO BTS EQUIPMENT WALL, FLOOR SOLID TINNED VIA TRAY OR FROM LNA OR ON ANTENNA GRADE ICEBRIDGE (WHEN REQUIRED) TOWER #6 AWG STRANDED CU WIRE FURNISHED W/KIT. MARK WITH GROUND RING GROUND WIRE #6 AWG 2—HOLE LUG GREEN TAPE (TYP). IA NOTE: go CIGBE (GROUND BAR), SIMILAR C TO DETAIL 509 MOUNTED f� O (� O 1. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA LOCATIONS AND NEAR/BELOW ANTENNA O CONNECTION ORIENTATION. PROVIDE AS REQUIRED. #2 AWG 2—HOLE LUG .5 o• o 0 0 0 0 0 0 o c � ® NOTE: a E DO NOT INSTALL CABLE GROUND #2 AWG CU STRANDED TWO --HOLE LUG, BOLTED TO GROUND CABLE GROUNDING KIT AT A BEND AND ALWAYS DIRECT WIRE WITH GREEN, 600V, T�*TWO-HOLE AR USING 3/8"-16 x 1 1 /4"STAINLESS GROUND WIRE DOWN TO CIGBE THWN INSULATION BONDED TO TOWER STEEL OR STEEL HEX HEAD BOLTS AND HARDWARE. AT TOWER MONOPOLE LUG, TO BE USED WITH IA � #2 AWG SOLID TINNED BARE CU * GROUND BARS AT BOTTOM WIRE OR STRANDED CU WIRE WITH DETAIL(575 CONNECTION OF GROUND WIRE TO OF TOWERS OR MONOPOLES GREEN 600V THHN/THWN NTS _ SHALL USE EXOTHERMIC OR INSULATION TO ANTENNA GROUNDING BAR (CIGBE) HIGH COMPRESSION CONNECTION. STRUCTURE, BUILDING, RING TOWER/MONOPOLE GROUND OR MGB INSTALLATION OF GROUND WIRE DETAIL (508A�NTS _ DETAIL 522A a TO GROUND BAR NTS _ >I� a Li- may mr w v ® so,s f GI T s Q AT&T WIRELESS ENCHANTED A AT&T � %� IT CT J 4630 200TH STREET SHIN, SUITE K ��"j'L�,� a 10/01/03 ISSUED FOR CD REVIEW LCN .�� EdC ELECTRICAL DETAILS LYNNWOOD, WA 98036 PHONE: (425) 670-8651 1741 S 356TH AVE A 09/26/03 ISSUED FOR CD REVIEW LCN JMG EJC uL . AN +- FAX: (425) 712-0846 FEDERAL WAY, WA 98003 AT&T 1SERVICES, INC. NO. DATE REVISIONS BY CHK AFRV $ A II GTo� 2729 JOB �R DRAWING Wj R PROPEC ROT PARK DRNE Go RANCHO CORDOVA, CA 95670 E; , SHOWN TDESIGNED BY: DRAWN ®Y: 24897—fi12 HOO—STTLWASS70---EOt Do � Architects - Engineers, F.C. � 5 4 3 2 1 DECEIVED O C T 2 0 2003 CITY OF FEDERAL WAY BUILDING DEPT. RF CABLE MINIMUM BEND RADIUS ANDREW HELIAX CABLE MODEL NUMBER COAXIAL CABLE NOMINAL SIZE COAXIAL CABLE MINIMUM BEND RADIUS FSJ1-50A 1 /4" (0.25") 1 " (25 mm) EFX2-50 3/8" (0.375") 1.75" (45 mm) FSJ2-50 3/8" (0.375") 1 " (25 mm) FSJ4-5013 & FSJ4RN-50B 1 /2" (0.5") 1.25" (32 mm) LDF4-50A & LDF4RN-50A 1 /2" (0.5") 5" (127 mm) LDF5-50A & LDF5RN-50A 7/8" (0.875") 10" (254 mm) VXL5-50 7/8" (0.875") 5" (127 mm) LDF6-50 & LDF6RN-50 1 1 /4" (1.25") 15" (381 mm) LDF7-50A & LDF7RN-50A 1 5/8" (1.625") 20" (508 mm) VXL7-50 1 5/8" (1.625") 15" (381 mm) LDF12-50 2 1 /4" (2.25") 24" (610 mm) COMMSCOPE CABLE MODEL NUMBER COAXIAL CABLE NOMINAL SIZE COAXIAL CABLE MINIMUM BEND RADIUS FXL 540 1/2" (0.5") 2" (51 mm) SFX 500 1 /2" (0.5") 1.25" (32 mm) CR 50 540 1 /2" (0.5") 4" (102 mm) CR 50 1070 7/8" (0.875") 8" (203 mm) CR 50 1873 1 5/8" (1.625") 15" (381 mm) RFS CABLE MODEL NUMBER COAXIAL CABLE NOMINAL SIZE COAXIAL CABLE MINIMUM. BEND RADIUS 81 1028-001 81 1028—F01 811028-003 811028—FO3 1 /4" (0.25") 1 " (25 mm) 810917-001 810917—FOl 810917-003 810917—F03 3/8" (0.375") 2" (51 mm) 810918-001 810918—F01 810918-003 810918—FO3 810918-083 810918—F83 1 /2" (0.5") 3" (76 mm) 81 1026-001 81 1026—F01 81 1026-003 811026—F03 811026-083 811026—F83 1 /2" (0 �,"} 1.3" (33 mm) 810921-001 810921—F01 810921-003 810921—FO3 810921-083 810921—F83 7/8" (0.875") 5" (127 mm) 810916-001 810916—F01 810916-003 810916—F03 810916-083 810916—F83 1 1 /4" (1.25") 8" (203 mm) 810920-001 810920—F01 810920-003 810920—F03 810920--083 810920—F83 1 5/8" (1 625") 8" (203 mm) 81 1046-001 81 1046—F01 811046-003 811046—FO3 811046-083 811046—F83 2 1 /4" (2.25") 9.5" (241 mm) MANUFACTURERS RECOMMENDED TORQUE VENDOR CONNECTOR (DIN) CONNECTOR (N) CONNECTOR (SMA) ANDREW 220--265 IN —LB 15-20 IN —LB 8 IN —LB HUBER+SUHNER 220-265 IN —LB 6-10 IN —LB 7.1-9.7 IN —LB COMMSCOPE 220 IN —LB 15 IN —LB NA (TYPICALLY) 12' TO 24" 120" MAX Q ANTENNA CABLE WEATHERPROOFING KIT (SEE NOTE 3) Q CABLE GROUND KIT #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) N (SEE NOTE 1 & 2) ANTENNA CABLE CONNECTOR cv CONNECTION OF CABLE GROUND KIT TO ANTENNA CABLE NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 3. WEATHER PROOFING SHALL BE TWO—PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. DETAIL (51 3A NTS TO RADIO CABINET (NOKIA/ERICSSON) T1—SURGE SUPPRESSOR ATLANTIC SCIENTIFIC NO. 90700 PORT MARKED "PROTECTED" DIN RAIL RJ48 (TYP) ATLANTIC SCIENTIFIC 21607 PLASTIC (SEE NOTE 1) NOTCH RING TONGUE COMPRESSION TERMINAL (SEE NOTE 2) LABEL PORT MARKED #6 AWG STRANDED CU,- "UNPROTECTED" THHN GREEN INSULATED RJ48 (TYP) GROUND WIRE BONDED TO MGB OR GROUNDED ENCLOSURE NOTES: TO TELCO NIU 1. MOUNT SURGE ARRESTOR ON EXISTING DIN RAIL IF AVAILABLE, OTHERWISE PROVIDE ATLANTIC SCIENTIFIC MODEL NO. 21605, 5—INCH 4—UNIT DIN RAIL, OR EQUAL, AND SECURELY MOUNT TO TELCO BOARD FURNISHED BY BECHTEL. 2. ATTACH GROUND WIRE TO THE DIN RAIL, SEPARATELY FROM THE RAIL R F CABLE MINIMUM BEND RADIUS AND MANUFACTURERS MOUNTING HARDWARE, USING STAINLESS STEEL BOLT, LOCKING WASHER RECOMMENDED CONNECTOR TORQUE TABLES AND NUT OR SELF —TAPPING MACHINE SCREW THAT FIRMLY GRIPS THE DIN RAIL BY ELECTRICIAN. D ETAI L 309 3. TVSS MAY BE ORIENTED TO SUIT SITE REQUIREMENTS. T1 SURGE SUPPRESSOR DETAIL (015 d NTS _ w A n Z mm sm>� AT&T WIRELESS ENCHANTED PARKWAY AT&T RI✓�I,r��TT1 mmm I I4630 200TH STREET SW, SUITE K STTL ASS Ir Cr "u LYNNWOOD, WA 98036 Q 10/09/03 ISSUED FOR CD REVIEW l.crl JMc EaC ELECTRICAL DETAILS PHONE: ij425) 670-8651 1741 S 356TH AVE A tDA /03 ISSUED FOR CD REVIEW LCN JMG EdC p �- � � a�a Ell I 1 1F�1lC: 4425) 712-084fi AT&T WIRELESS SERVICES, INC. s r � .a . Idcro� FEDERAL WAY, WA 98003 2729 PROPECT PARK DRIVE No. REWStoNS BY CHK APRV Jab Nt�dtBBR o tA"NG N mmR I REV E.. Architects -Engineers, P.C. RANCHO CORDOVA, CA 95670 �E: AS SHOWN DESIG14ED BY: DRAWN BY: 24897-612THOO—SlTLWASS70—EO2 0 Q 6 5 4 3 2 1 RECEIVE OCT 2 0 2003 CITY OF FEDERAL NAY BUILDING DEPT. W a Lo �r- I I I I I I I I I I I I I I I I I I f I I I I I I I I I I I I I I TO UTILI7 2. FOR UNDERGROUND INSTALLATION FURNISH AND INSTALL ONE 1" RMC FOR POWER TO UMTS CABINET SLAB. TRANSITION FROM RMC CONDUIT TO 1" LIQUIDTIGHT (LFMC) CONDUIT FOR ENTRY TO NORTEL CABINET. FOR ABOVE GROUND INSTALLATION USE 1" IMC CONDUIT, 3. CONTRACTOR SHALL COIL AND TAPE AN ADDITIONAL 5'-0" OF WIRING FOR CONNECTIONS BY NORTEL AFTER INSTALLATION OF NORTEL EQUIPMENT. 4. FURNISH AND INSTALL 1 /0 AWG EQUIPMENT GROUND CONDUCTOR FROM GROUND RING TO REACH CABINET GROUND STUD IN MIDDLE OF INSTALLATION FRAME. CUT, COIL, AND TAPE TEN FOOT PIGTAIL FOR CONNECTION BY NORTEL. 5. FURNISH AND INSTALL ONE 1" CONDUIT FOR T1 PCM CABLE. TRANSITION DS1 CONDUIT TO LIQUIDTIGHT (LFNC-B) CONDUIT AT SLAB TO THE CONNECTION POINT ON THE UMTS CABINET. NORTEL TO FURNISH AND INSTALL ALARM AND T-1 CABLE AS REQUIRED. 6. FURNISH AND INSTALL DS1 TVSS. SEE DETAIL 1015, CONNECT GROUND WIRE TO MGB OR GROUND ENCLOSURE. 7. FOR CABINET MOUNTING ON A FRAME SEE DETAIL 1265. g. IF ADDITIONAL DIN RAIL REQUIRED FOR DS1, GROUND AS SHOWN. AC POWER, DS1 CABLE AND GROUNDING INTERFACE TO NORTEL UMTS iBTS ENCHANTED PARKWAY STTLWAS 7 1741 S 356TH AVE FEDERAL WAY, WA 98003 0 D ETAI L (1'2-71 NTS — AT&T WIRELESS SERVICES, INC. 2729 PROPECT PARK DRIVE RANCHO CORDOVA. CA 95670 L^1JI IIV%7 1 I.1L OUTDOOR OVERLAY / GROWTH 0 10/01 /03 ISSUED FOR CD REVIEW LCN JMG EJC A 09/26/03 ISSUED FOR CD REVIEW LCN JMG EJC NO. I DATE I REVISIONS SY CHK JAPRV SCALE: AS SHOWN DESIGNED BY: DRAWN DY: 2 6019 -RED STATE Of WASHMIGTON AT&T WIRELESS 0 0J' n POWER AND GROUNDING SCHEMATIC JOB NUMBER ORaiA W NUMBER REVf 24897-612 THOO-STTLWASS70-03 0 1 RECEIVED OCT 2 0 2003 CITY OF FEDERAL WAY BUILDING DEPT.