07-103303 (2)CITY OF CITY HALL F I L 33325 8th Avenue South �. Mailing Address: Box 9718 Federal Way 98 Federal Way, WA 98063-9718 (253) 835-7000 www.cityoffederalway.com July 11, 2007 Matt Englesby Pacific Telecom Services 568 1" Avenue South, Suite 650 Seattle, WA 98104 RE: File #07-103303-00-UP; SPRINT/NEXTEL @ ENCHANTED PKWY 1741 South 356th Street, Federal Way Dear Mr. Englesby: The City has completed an administrative review of the proposal to install an emergency generator on an existing concrete slab inside the existing fenced, compound. The proposal includes the installation of a Sprint ATS, and a Sprint Conduit as well as the proposed diesel generator. The Process I application is hereby approved by the City's Department of Community Development Services. Due to the nature of the proposal, a building permit will not be required. However, an electrical permit will be required for the installation of the generator, issued by the City's Building Division prior to beginning any work. This Process I decision shall not waive compliance with future City of Federal Way codes, policies, and standards relating to this site. The effective date of this decision is July 14, 2007 (three days from issuance). Pursuant to Federal Way City Code (FWCC) Section 22-356, any person who received notice of the administrative decision may appeal this decision to the Federal Way Hearing Examiner by July 30, 2007 (14 days after issuance). No work on the proposal can commence until the end of the appeal period. However, in that you are the only party of record, you may waive your right to appeal this decision. If you wish to waive your right to appeal, you must do so in writing or by email, to the attention of Laura Kim, Associate Planner, laura.kim@cityoffederalway.com. Work may begin on the proposal once the City verifies that an appeal waiver has been received and a building permit has been issued by the City. If you have any questions regarding this letter, please contact Laura Kim at laura.kim@cityoffederalway.com or 253-835-2641. Sincerely, -]� 11� Kathy McClung Director of Community Development enc: Stamped Approved Plans Doc 1 D 41510 s Together with NEXTEL N)� ENCHANTED PARKWAY PROJECT INFORMATION PROJECT DESCRIPTION: SPRINT-NEXTEL PROPOSES TO AMEND AN EXISTING UNSTAFFED TELECOMMUNICATIONS FACILITY WITH THE ADDITION OF A 40KW DIESEL GENERATOR AND FUEL TANK MOUNTED ON EXISTING CONCRETE PAD SITE ADDRESS: 1741 S 356TH STREET FEDERAL WAY, WA 98003 PROPERTY OWNER: LLOYD RUSSELL 174 S 356TH ST FEDERAL WAY, WA 98003 APPLICANT: SPRINT/NEXTEL 10545 WILLOWS RD NE SUITE 100 REDMOND, WA 98052 PROJECT CONTACT: MATT ENGLESBY PHONE: (206) 310-2240 EMAIL- MENGLESI3Y@PTSWA.COM LATITUDE: 47' 16' 57.16" N LONGITUDE: 122' 18' 39.63" W LAT/LONG TYPE: NAD 83 ELEVATION: 0' AMSL PARCEL NUMBER: 282104-9178-06 CURRENT USE: TELECOMMUNICATIONS FACILITY PROPOSED USE: TELECOMMUNICATIONS FACILITY POWER: PSE PHONE: 1-888-225-5773 TELCO: QWEST PHONE: JURISDICTION: CITY OF FEDERAL WAY ZONING: CB APPLICABLE CODE: 2003 IBC CONSTRUCTION TYPE: II-B OCCUPANCY TYPE: UNOCCUPIED PROJECT AREA: APPROX. 40 S.F. VALUATION: $10,000 VICINTY MAP WA0456 _ FedeYaflAlay -fl s 350th_ St T61 g 351st st = . f $ 351ni�5t 1 sAt 1a2A SITE 4Lp ro N to 99 4 : a �t DRIVING DIRECTION s 3Lkt st Enchamad aide s S-351-M SF ts am pr U3 a oa m - UL- N - DEPART: 10545 WILLOWS RD NE, REDMOND, WA 98052 TURN RIGHT ONTO SR-908 TURN OFF ONTO RAMP TOWARDS 1-405 / RENTON CONTINUE ON SR-518 TURN OFF ONTO RAMP TOWARDS 1-5 / PORTLAND AT 1-5 EXIT 142E TURN OFF ONTO RAMP TOWARDS WA-161 S / PUYALLUP MERGE ONTO SR-18 TURN LEFT ONTO SR-161 (ENCHANTED PKWY S) TURN LEFT ONTO S 356TH ST ARRIVE: 1741 S 356TH ST, FEDERAL WAY, WA 98003 DRAWING INDEX CURRENT WtM CONSTRUCTION DRAWINGS AITIMA S. DATE: SPRINT/NEXTEL: LANDLORD: CONST: S/A: I R.F.: ZONING: A&E: T-1 TITLE SHEET AND GENERAL INFORMATION G-1 GENERAL NOTES A-1 SITE PLAN A-2 ENLARGED SITE PLAN A-3 GENERATOR AND ATS DETAILS E-1 GROUNDING PLAN AND ELECTRICAL NOTES E-2 MO POWER DIESEL GENERATOR AND ALARM E-3 ATS CABLE SCHEDULE AND ATS ALARM iNN E-4 ATS ALARM WIRING-CDMA ROVE D E-5 ELECTRICAL DETAILS PLANNING City :of. Faders! Way Dept. of Community Dewelc Penft 0-+—[l /+7�0 3 - OF PROJECT TEAM DESIGN TEAM THOMAS R. HOLLAND. ALA PACIFIC TELECOM SERVICES, LLC 568 FIRST AVE S. SUITE 650 SEATTLE, WA 98104-2804 CONTACT: STEVE ISHIHARA PHONE: (206) 342-9000 EXT. 412 FAX: (206) 903-8513 EMAIL: SISHIHARA®PTSWA.COM ZONING CONTACT PACIFIC TELECOM SERVICES, LLC 568 FIRST AVE S, SUITE 650 SEATTLE, WA 98104-2804 CONTACT: MATT ENGLESBY PHONE: (206) 342-6391 E-MAIL: MENGLESBY®PTSWA.COM PRIME CONTACT SPRINT/NEXTEL 10545 WILLOWS RD NE SUITE 100 REDMOND, WA 98052 CONTACT: BRYAN ADAMS OFFICE: (425) 278-2109 PROJECT MANAGER RECEIVE[ PACIFIC TELECOM SERVICES, LLC 568 FIRST AVE S, SUITE 650 SEATTLE, WA 98104-2804 JUN 8 �OQ7 CONTACT: LORI CHASE PHONE: (206) 342pj�-�63yy85 EMAIL: LCHASE f It�I ]F FEDERAL BUILDING DEPT. *rint- )00 Together with NEXTEL PACIFIC TELECOM SERVICES, LLC Swft* WA. 66104 R—: (2N) 349i Fm (206) 909-6516 4072 THOMAS R. HOLLAND STATE OF WASHINGTON ' 1 � Q FI ~ U N Vl O N m L-2 Z V) O U O IY V U. O 0 p w � � is S o Ty-1 TITLE SHEET AND GENERAL INFORMATION JOB # DRAWING # WA04.96 T-1 REVISION 1 0 STRUCTURAL STEEL NOTES 1. ALL STEEL WORK SHALL BE PAINTED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS AND IN ACCORDANCE WITH ASTM A36 UNLESS OTHERWISE NOTED. 2. ALL WELDING SHALL BE PERFORMED USING E70XX ELECTRODES AND WELDING SHALL CONFORM TO AISC AND AWS D1.1. WHERE FILLET WELD SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM SIZE PER TABLE J2.4 IN THE AISC "MANUAL OF STEEL CONSTRUCTION". PAINTED SURFACES SHALL BE TOUCHED UP. 3. BOLTED CONNECTIONS SHALL BE ASTM A325 BEARING TYPE (3/4"0) CONNECTIONS AND SHALL HAVE MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. 4. NON-STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA. ASTM A 307 BOLTS UNLESS NOTED OTHERWISE. 5. INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR, SHALL BE PER MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURE. THE ANCHOR BOLT, DOWEL OR ROD SHALL CONFORM TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. NO REBAR SHALL BE CUT WITHOUT PRIOR ENGINEERING APPROVAL WHEN DRILLING HOLES IN CONCRETE. SPECIAL INSPECTIONS, REQUIRED BY GOVERNING CODES, SHALL BE PERFORMED IN ORDER TO MAINTAIN MANUFACTURER'S MAXIMUM ALLOWABLE LOADS. 6. INSTALLATIONS WHERE THE GENSET IS LOCATED NEAR EXISTING CABLE TRAY SHALL HAVE A NOTE ON THE DRAWINGS CALLING FOR GRIP STRUT INSTALLATION OVER THE TRAY FOR TO PROVIDE FOR A WALKWAY FOR TECHS AND SERVICE PERSONNEL 7. EXISTING PLATFORM INSTALLATIONS SHALL INCLUDE THE INSTALLATION OF AN ANGLE UNDER THE STRUCTURAL MEMBER OF THE PLATFORM TO SECURE THE GENSET TO THE PLATFORM IN LIEU OF THE GATING. 8. SURFACE MOUNTING OF CONDUITS SHALL BE AVOIDED AT ALL POSSIBLE LOCATIONS WHERE PEDESTRIAN TRAFFIC CAN OCCUR. WHERE THIS IS UNAVOIDABLE, GRIP STRUT BRIDGING SHALL BE CALLED OUT FOR INSTALLATION TO PROTECT THE CONDUITS AND POTENTIAL FOR PERSONNEL TRIPPING HAZARDS. ELECTRICAL NOTt�: 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. 2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED BUS BARS. FOLLOW ANTENNA AND BTS MANUFACTURERS PRACTICES FOR GROUNDING REQUIREMENTS. GROUND COAX SHIELD AT BOTH ENDS AND EXIT FROM TOWER OR POLE USING MFR'S PRACTICES. 3. ALL GROUND CONNECTIONS SHALL BE CADWELD. ALL WIRES SHALL BE COPPER THHN/THWN. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND. 4. REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL PROVISION AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING STANDARDS. 5. RIGID CONDUIT SHALL BE USED WHERE DAMAGE CAN OCCUR FROM VEHICULAR TRAFFIC OR EQUIPMENT DELIVERY EXERCISES. 6. ATS AND GENSET LABELS ARE TO BE PROVIDED AND INSTALLED WITH SERIAL AND CASCADE NUMBERS FOR THE ATS AND GENSETS. LABELS SHALL BE ATTACHED VIA ALUMINUM OR SS SCREWS - CONSTRUCTION MANAGER TO PROVIDE TO SUBS FOR INSTALL AT SITE, DUE TO POSSIBLE ASSET TRANSFER ACTIVITY, UPON RECEIPT OF LABEL SPECIFICATION FROM SPRINT/NEXTEL. 7. NEW INSTALLATION SHALL BE PVC CONDUIT, USE SCH BO ABOVE GROUND AND SCH 40 BELOW GROUND. ALSO REFER TO CONSTRUCTION MANAGER DIRECTION FOR ANY CONDUIT EXPOSED TO TRAFFIC (VEHICLE OR FOOT). B. CONTRACTOR TO PROVIDE A NEW 66 BLOCK IF REQUIRED, WITH FURTHER ROUTING TO THE RBS EQUIPMENT CABINET AND LEFT WITH A 2' COIL OF WIRE. ALARM CABLING IN THE TELCO CABINET SHALL BE INSTALLED IN A NEAT FASHION WITH A 6" SERVICE COIL. CONTRACTOR SHALL NOT MAKE PUNCH DOWNS ON THE TELCO BOARD 66 BLOCK GENERAL NOTES: THE SPRINT/NEXTEL METHOD OF PROCEDURE (MOP) MOPS 2061108 INSTALLATION OF PAD MOUNTED GENERATOR SETS IS THE BASIS FOR ALL TECHNICAL INSTALLATION SPECIFICATIONS; AND IN THE EVENT THERE IS A CONFLICT BETWEEN THESE CONSTRUCTION DOCUMENTS OR THE INSTALLATION CHECKLIST AND THE GENSET MOP, THE CONTRACTOR SHALL FOLLOW THE DIRECTIVE DESCRIBED WITHIN THE MOP AND CONTACT CONSTRUCTION MANAGER TO APPRISE. EXCEPT NO PORTABLE GENERATOR S/0 CORD STILL BE REMOVED 2. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED IN THE DRAWINGS AND OWNER'S PROJECT MANUAL. 3. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE. 4. THE PROPOSED FACILITY IS UNMANNED AND IS NOT FOR HUMAN HABITAT. (NO HANDICAP ACCESS IS REQUIRED). 5. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND DRAWINGS PROVIDED BY THE SITE OWNER. DRAWINGS WERE PREPARED FROM SITE SPECIFIC DETAILS AND STANDARDIZED DETAILS DEVELOPED BY PACIFIC TELECOM SERVICES, LLC. STANDARDIZED DETAILS ARE TO BE CONFIRMED AND CORRELATED AT THE SITE BY THE CONTRACTOR. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. MODIFICATIONS DUE TO FIELD CONDITIONS MUST BE SUBMITTED TO, AND APPROVED BY, SPRINT/NEXTEL PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY THE CONSTRUCTION OPERATION. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED FOR CONSTRUCTION. 8. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. ALL INSTALLATIONS SHALL BE 100% CLEAN OF ALL DEPRIS AND METAL FILINGS SHALL BE REMOVED FROM ENCLOSURES, SITE AREA, FIXTURES, PLATFORMS, ETC. 9. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. 10. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 11. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. GENERA NOTES (CONT.): 12. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/VENDOR'S Together with NEXTEL SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE 0"' E . NA"ee2 nm"e assysaWff LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 13. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. PACIFIC TELECOM SERVICES, CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH LLC ALL LAWS, ORDINANCES, RULES, REGULATIONS AND ,,,,„ nM _, w = e.Z wti LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL - (2 AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 14. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED A072 GISTEREP BY THIS CONSTRUCTION PROJECT UNLESS NOTED A CT OTHERWISE. 15. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED THOMAS R. HOLLAND MATERIALS IF APPLICABLE TO THIS FACILITY AND OR STATE OF WASHINGTON 1 PROJECT SITE. � 16. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A1OBC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. 17. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. 18. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS. OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S PROPOSAL IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. 19. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS. 20. CONTRACTOR SHALL CALL WASHINGTON UTILITY COORDINATING COUNCIL SERVICE FOR UNDERGROUND UTILITY MARKOUT PRIOR TO CONSTRUCTION 1-800-424-5555. 21. IN CASE OF CONFLICT BETWEEN THE AFORE REFERENCED SPRINT/NEXTEL STANDARDS AND INSPECTION CHECK LIST, THE GENERAL CONTRACTOR SHALL CONTACT CONSTRUCTION MANAGERS' PROJECT MANAGER TO RESOLVE, IN WRITING, ANY DEVIATIONS. RECEIVED JUN 1 8 2007 CITY OF FEDERAL WAY BUILDING DEPT. F- Q F- m 0 0 O N m - CD 0 O O Z Z�� r 0U Z O > W U � LLO � O w W o G-1 GENERAL NOTES JOB # DRAWING # WA0456 G-1 REVISION 1 0 /EXISTING BUILDING EXISTING NEXTEL 5'-0' X 9'-0" EQUIPMENT CONCRETE PAD EXISTING WAVEGUIDE EXISTING SPRINT PPC PROPOSED SPRINT ATS 4 A-3 PROPOSED SPRINT CONDUIT (APPROX 35' RUN) EXISTING SPRINT EQUIPMENT ON CONCRETE PAD PROPOSED NDM 40kw DIESEL GENERATOR AND FUEL TANK ON EXISTING CONCRETE PAD xI X —X—X— X—XJ x—x—x--x—x—x7%—X—L x EXISTING (2) 6'-0" ACCESS EXISTING TELCO RISER EXISTING BOLLARD (TYP) EXISTING 150'-0" LATTICE TC ARRAYS NOT SHOWN FOR CL EXISTING CINGULAR EQUIPMEI EXISTING T—MOBILE EQUIPMEI CONCRETE PAD x — x — x — x — x — x — x — x x—x--x—x P 2 , 4 —3 A-3 A-4 A-4 U x is x uj N 4 PROPOSED NEXTEL ATS I I i 1 I i A-3 EXISTING ELECTRICAL VAULT —' —J x X—X X—X—%— x I —X—X—X—%—X—X—X—X—X—X—X—X—X—%—X—X—X—X—X—X—X—X— —%—X—X—X—X N X—X—X—X— —X—X—X—X—X—X—X—%—X— PROPOSED NDM CONDUIT 4'-6" 12'-7" (APPROX 65' RUN) EXISTING 6'-0" CHAIN LINK FENCE WITU3� STRANDS RA.RELY[R�,. — 131'-0"t FENCED AREA LEXISTING BUILDING SCALE. (24' X 367 3/16's1'-0' SCALE (11- X 177 3/32'-1'-0' 6 5 4 3 2 1' 0 5' RECEIVED CITY OF FEDERAL WAY BUILD ENLARGED SITE PLAN I I 111� e Together with NEXTEL +mz wam.i 1n x w+rc +m hn+u, .3y31br+m PACIFIC TELECOM SERVICES, LLC e ., W& —0. p'— C..) 3a-9M Pm: ("S) W3-"13 4072 -_ , I THOMAS R. HOLLAND STATE OF WASHINGTON , 1 � � r � V 0 0 o ry m p O 3z O ZL� 0 Z c- U O > Lu Q�v rvOw0 00 w w L �Q Qp ±LLL A-2 ENLARGED SITE PLAN JOB # DRAWING # WA0456 A-2 REVISION I 0 ASCO 7000 SERIES AUTOMATIC TRANSFER SWITCH (30-230 AMPS) (4) .43 DIA, GENERAL NOTES MOUNTING HOLES-y 1. TYPE 3R/4/4X/12 WALL MOUNTED ENCLOSURE. L 2. FINISH TYPE 3R/4/12: ANSI 61 GREY. TYPE 4X CONSTRUCTED OF 12 GAUGE 304 STAINLESS STEEL. 3. PLATED DOOR CLAMPS AND PADLOCK HASP ON LEFT SIDE. 4. SINGLE DOOR HINGED ON RIGHT 5. TERMINALS - SCREW TYPE LUGS FOR EXTERNAL POWER CONNECTIONS. 6. THREE POLE SWITCH WITH SOLID NEUTRAL SHOWN FOR REFERENCE. 7. THREE POLE SWITCH WITH SOLID NEUTRAL SHOWN FOR REFERENCE. B. NEUTRAL CONFIGURATIONS: AN OPTIONAL FULL RATED NEUTRAL CONFIGURATION FOR EACH SOURCE AND THE LOAD MAY BE PROVIDED. WHEN EQUIPPED IT IS IN ONE OF THE FOLLOWING FORMATS AS SPECIFIED BY THE CATALOG NUMBER NO. NEUTRAL TYPE: (A) SOLID (COPPER BUS) NEUTRAL (B) SWITCHED NEUTRAL POLE (C) OVERLAPPING NEUTRAL POLE CAM-LOK CONNECTOR ENCLOSURE EXISTING CONCRETE FR 0 NT GENERATOR VENT FRONT VIEW WITHOUT DOOR 1�W 000 00 rIc D ® I I TRAL MAL FRONT VIEW WITH DOOR KNOCKOUTS: LEAVE INTACT FOR TYPE 12 REMOVE FOR TYPE 12 RIGHT SIDE N NOT AVAILABLE ON TYPE 4,4X 2„ SWITCH RATING RANGE OF WIRE BOTTOM VIEW (AMPS) 30-150 (1) #14 TO 4/0 AWG AL-CU WIRE 200-230 (1) #14 TO 4/0 AWG COPPER WIRE E) PROPOSED NEXTEL 40kw SINGLE SIDE SERVICE GEN£RATO PROPOSED NEXTEL 77 GALLON DIESEL FUEL TANK 8.-o. TOP ATS CABINET OUTDOO SCALE: (24"X36': NOT TO SCALE SCALE (11'Xi 7): NOT TO SCALE r 00 r UG STUDS 0 BACK SCALE: (24WB-): 1/2"=1'-0" SCALE: (11"X17): 1/4"=1'-O" 7" -- —� - 75-.50 COMBINATION n PILOT KNOCK -OUTS. TOP AND BOTTOM TOP VIEW TYP TOP AND BOTTOM --(4) .37-DIA. EXTERNAL ASCO 7000 SERIES AUTOMATIC TRANSFER SWITCH (30-230 AMPS) INTERIOR WALL -- DIMPLED MOUNTING HOLES q" �. 1'-1" OLID EUTRAL NORMAL 1. 1'-3" L 1'-6" FRONT VIEW FRONT VIEW WITHOUT DOOR WITH DOOR GENERAL NOTES 1. TYPE 1 WALL MOUNTED ENCLOSURE. 2. STANDARD FINISH - LIGHT GREY, ANSI 61. 3. KEY LOCKABLE HANDLE. 4. REMOVEABLE SINGLE DOOR. 5. TERMINALS - SCREW TYPE LUGS FOR EXTERNAL POWER CONNECTIONS. 6. ® CENTER OF GRAVITY. 7. THREE POLE SWITCH WITH SOLID NEUTRAL SHOWN FOR REFERENCE. ATS CABINET INDOOR SCALE: (24"X367:NOT TO SCALE SCALE (11"X177: NOT TO SCALE x V a m GROUND LUG MOUNTING STUDS 7�. SWITCH RATING RANGE OF WIRE (AMPS) 30-150 (1) #14 TO 4/0 AWG AL-CU WIRE 200-230 (1) #14 TO 4/0 AWG COPPER WIRE 3 A _q GENERATOR HOUSING !� TOP OF GENERATOR IT11FUEL TANK 3/4"0 EPDXY SET ANCHOR BOLTS, 4" MIN. EMBED (TYP) 1—TOTAL OF (4) BOLTS MIN. VIBRATION ISOLATION TO BE SUPPLIED BY GENERATOR n CONy2�T��VgrBY I . , I CITY OF FEDERAL WAY FOUNDATION SECTION BUILDING DEP _ . 2 SCALE: (24"X36-):1-1/2" SCALE: (11'X17'):3/4' = V-0" ■ Together with NEXTEL nor. w.r+4.,m PACIFIC TELECOM SERVICES, LLC ww Phph_(mq 3a2 M00 i— (m!) 903-8513 - `" r / I THOMAS R. HOLLAND STATE OF WASHINGTON 1 1 � O a� O 4 O 3o Z 0 0 U Z w0� Iv1LO O w w � � Q o A-3 GENERATOR AND EQUIPMENT DETAILS JOB il} DRAWING # WA0456 A-3 REVISION I D PROPOSED 4OKw DIESEL GENERATOR ON CONCRETE PAD i 2 x TDETAIL axx —x —x—x—x— NERATOR FRAME BOND SEE SAME SHEETNERATOR FENCE BOND SEE DETAIL SAME SHEET GENERATOR FRAME TWO HOLE BOLTED x— iLl x I x x—x—x—'L—=)L—�=J—� PROPOSED #2 AWG ATS CASE I BOND I 1 \SPROO INT ATS APPROX. LOCATION OF EXISTING SPRINT GROUND RING (CONTRACTOR TO FIELD VERIFY EXACT LOCATION) —x—x—x—x—x—x—x—x—x—x—x—x—x—x—x—x--x—x—x GROUND LUG, SS HDW 0 #2 AWG TINNED WIRE 0 NOTE: PREP SURFACE BEFORE GROUNDING - USE NO-OX BETWEEN LUG AND STEEL. USE SAME COLOR TOUCH UP PAINT TO PREVENT RUST. GENERATOR FRAME BOND NOT TO SCALE SCALE: (24' X 387 1/4'-1'-0' SCALE (11' X 177 1/B'-7' v NOTES: 1. POWER INTERRUPTION IS ALLOWED ONLY UNDER THE FOLLOWING CONDITIONS; OUTSIDE OF THE MORNING AND AFTERNOON DRfVE TIMES. CUT DURATION MUST BE GUARANTEED TO BE LESS THAN 2 HOURS MAX. IF THIS CAN NOT BE GUARANTEED STAND-8Y POWER MUST BE CONNECTED OR INTERRUPTION MUST BE PERFORMED DURING THE MAINTENANCE WINDOW. 2.EXISTING DUPLEX Gn ON THE GENERATORS SHALL BE CHANGED OUT TO A NON -GF1 OUTLET TO AVOID LOSS OF POWER TO THE BATTERY CHARGER AND BLOCK HEATERS. NON-Gn OUTLET SHALL BE SERVICED BY ONE 20AMP CIRCUIT IN FLEX CONDUIT. EXOTHERMIC WELD COLD GALVANIZED AFTER COOLING — 12" M GLN .aL GROL]NDING OTES: TO BURIED GROUND RING WITH 1. EXOTHERMIC WELD ALL CONNECTIONS PARRALLEL TAP WELDS, USE SHORT RODS WHERE STANDARD GROUND RODS ARE Tpgetherwith NEXTEL NOT USED, SEE CABLE TO CABLE DETAIL. 0!4 MUIM 0 xc sum im WA 99D52 2. MAKE ALL GROUNDING CONNECTIONS AS SHORT AS POSSIBLE, MINIMUM =m D. FlIDNC 4T5$7!.]ADO BENDING RADIUS IS B". 3. CLEAN ALL SURFACES AND BRUSH WITH BRONZE BRUSH PRIOR TO MAKING GROUND CONNECTIONS, PAINT ALL EXOTHERMIC WELDS TO GALVANIZED OBJECTS WITH GALVANIZE PAINT, USE NO-OX COMPOUND WITH METAL TO METAL PACIFIC TELECOM SERVICES, CONNECTIONS. LLC 4. INSTALL 5/8" X 10' COPPER CLAD GROUND RODS IN LOCATIONS SHOWN, W. nm Awn.. S. SuN. M S.�, WA. NIM �Mns (M) 3.2 Nc Fs (M) 9W] 15 DISTANCE 10'-0" MINIMUM TO 15'-0" MAXIMUM BETWEEN RODS. 5. GROUND SYSTEM MUST BE INSPECTED BY CONSTRUCTION MANAGER PRIOR TO C) BACKFILL, PROVIDE 24 HOURS NOTICE. 6. ALL BONDS SHALL BE #2 AWG BARE, THINNED, SOLID COPPER UNLESS OTHERWISE NOTED. THE GENSET SHALL BE GROUNDED TWICE IN DIAGONAL CORNERS. ONEGROUND TO THE TANK FRAME AND THE SECON❑ TO THE GENERATOR ENCLOSURE x — x — x — x — X—x—FRAME. IT IS ACCEPTABLE TO GROUND THE TANK AT BOTH LOCATIONS WITH A rA-0721s7. JUMPER FROM THE TANK TO THE GENSET ENCLOSURE. THESE GROUNDS SHALL BE ON THE OUTSIDE OF TH£ UNIT TO BE VISIBLE BY ALL. ' PROPOSED NEXT \ ATS PROPOSED #2 AWG ATS CASE BOND I I APPROX. LOCATION OF EXISTING NEXTEL GROUND RING (CONTRACTOR TO FIELD VERIFY EXACT LOCATION) X —X — FENCE POST FINISHED GRADE FENCE BONDING CONCRETE FOOTING CONDUCTOR FENCE BONDING DETAIL NOT TO SCALE GROUNDING PLAN 12 GRCUNDING PLAN NOTES - CDPROVIDE AND INSTALL #2 AWG BARE, TINNED SOLID COPPER CONDUCTOR FROM THE GENERATOR FRAME TO THE GENERATOR GROUND ROD. �2 PROVIDE AND INSTALL A 5/8" X 10'-0" COPPER CLAD STEEL GROUND ROD APPROXIMATLEY 24" FROM GENERATOR PAD, FOR CASE BOND. O3 PROVIDE AND INSTALL A #2 AWG BARE, TINNED SOLID COPPER CONDUCTOR FROM THE GROUND ROD TO THE NEAREST POINT ON THE EXISTING GROUND RING. O4 PROVIDE AND INSTALL 02 AWG BARE, TINNED SOLID COPPER CONDUCTOR FROM THE FUEL TANK FRAME TO THE FUEL TANK GROUND ROD. ATS NOTES: IF THE ATS IS INSIDE THE CELL SITE ENCLOSURE, THE ATS CASE SHALL BE BONDED TO THE HALO GROUND RING INSIDE THE ENCLOSURE WITH A #& AWG COPPER WIRE. IF THE ATS IS OUTSIDE THE ENCLOSURE, IT SHALL BE BONDED TO THE EXTERNAL DROUND RING WITH A #2 AWG SOLID TINNED COPPER WIRE. THE SURGE ARRESTORS DESCRIBED IN THIS MOP ARE TO BE MOUNTED ON THE MOUNTING PLATE SOLD BY THE MANUFACTURER. THEY MAY BE GROUNDED IN ONE OF THREE WAYS: 1. IF THE ARRESTOR MOUNTING PLATE IS MOUNTED ON THE TELCO BOARD AND IF THE TELCO GROUND BAR IS BONDED TO THE EXTERNAL GROUND RING, THE PLATE MAY BE BONDED TO THE TELCO GROUND BAR WFTH A #2 AWG INSULATED STRANDED COPPER WIRE AND SUITABLE COMPRESSIONOTYPE 2-HOLE LUGS. 2. IF THE ARRESTOR PLATE IS NOT MOUNTED ON THE TELCO BOARD, BOND IT DIRECTLY TO THE EXTERNAL GROUND RING WITH A #2 AWG SOLID TINNED COPPER WIRE. USE A PVC CONDUIT THROUGH THE SHELTER WALL AT A 45 DEGREE ANGLE TO ALLOW THE GROUND LEAD TO EXIT THE SHELTER FOR BONDING TO THE EXTERNAL GROUND RING. 3. IF AN EXISTING #2 AWG GROUND CONDUCTOR EXISTS THE SHELTER (TO THE EXTERNAL GROUND RING) WITHIN 2FT OF THE MOUNTING PLATE LOCATION, THE PLATE MAY BE BONDED USING A #2 AWG INSULATED STRANDED CONDUCTOR WITH A COMPRESSION TYPE "C" TAP AND A SUITABLE COMPRESSION TYPE 2 HOLE LUG. MAKE ALL CONNECTIONS TO THE ATS CASE, THE GENERATIOR FRAME, THE EXTERNAL FUEL TANK (IF PRESENT AND IF SUPPORTED BY THE MANUFACTURER) AND THE SURGE ARRESTOR MOUNTING PLATE WITH SUTABLE 2-HOLE COPRESSION-TYPE LUG RAND STAINLESS -STEEL SCREWS, STAR -TYPE LOCK WASHERS AND LUG CONTACTS THE MAiINGVE PAINT AT THE METAL SURFACE 1NOINT OUES710NET0 EE S�REQG" FI METAL -TO -METAL CONTACT. APPLY ANTIOXIDANT TO THE MATING SURFACES. ENSURE THAT ALL UNDERGROUND OR OUTDOOR CONNECTIONS TOAjffOjND8IG200� SYSTEM ARE EXOTHERMICALLY WELDED (CAD -WELDED). PERFORM ALL GROUNDING WORK IN ACCORDANCE WITH STDIbffV&,FEDERALV CONSTRUCTION STANDARDS RI III ntNG DEPT ELECTRICAL NOTES Q G MF- 0 0 0 O z�� 0 Z EL O > x U ,wL.LLO U p w w 0 Q O E-1 GROUNDING PLAN AND F ELECTRICAL NOTES JOB # I DRAWING ! WAO45fi I E-1 REVISION o MQ POWER DIESEL PADMOUNT GENERATOR SET CONTROL PANEL REMOTE START ALARM EXPANSION BOARD ' WEAK BATTERY 9 NC BLK K5 10 C l �I + LOW BATT VOLTAGE 11 INC K6 12 C HIGH BATT VOLTAGE 13 NC K7 14 C LOW ENGIN TEMP 15 NC K8 I+ 16 I C hrWHT— 21 NC BRN— FAULT #1 22 � C j-I-BLU— LEAK DETECT 23 NC ` RED — FAULT #2 l 241 C I GRNLLIT — ENGINE RUNNING 25 INC FAULT #3 26 1 35% LOW FUEL 27 NC } FAULT #4 i 28 F}-' ' 29 FNC ` FAULT #5 30 ❑C ` l GENERATOR FAILURE 31 NC BILK, FAULT OUT #5 I j 32 C � �-f-WHT L—_------�_�J STRANDED WIRE 2 ASCO 7000 ATS STRANDED WIRE STRANDED WIRE NOTES: O G:D'V-) a GND O O +/_ o +/--0 GND v) ii GND 0 O GND V)) GND 0 O O 0 GND v�i ii GND 0 GND ii GND O O 1 GND w a GND fo O GND a GND O O O +/_ 0 o +/- GNO V) Of GND 0 O O O +/- CWD o Of- GND V GND 0 O O GND u0) a GND O O O +/_ o +/- GND ' �a GND 0 O O oc GND V) ii GND O O O O +/_ : +/- GND o) a GND 0 O O GND vV) d GND O O +/_ Lo' o +/- ct GND V) a GND 0 O O O +/_ wo o +/- GND V) a GND 0 O O O O +/_ ' o +/- GND N a GND 0 O O +/_ 5 o +/D�0 GND N a GN O 1. SEE DETAIL 1, SHEET E-3 FOR ATS CABLE SCHEDULE 2. CONTRACTOR TO PROVIOE A NEW 66 BLOCK IF REQUIRED, Wn-H FURTHER ROUTING TO THE RBS EQUIPMENT CABINET AND LEFT WITH A 2' COIL OF WIRE. ALARM CABLING IN THE TELCO CABINET SHALL BE INSTALLED tN A HEAT FASHION WITH A 6" SERVICE COIL CONTRACTOR SHALL NOT MAKE PUNCH DOWNS ON THE TELCO BOARD 66 BLOCK WHT/BLU (UTILITY POWER) BLU/WHT WHT/ORG (GENERATOR POWER) ORG/WHT WHT/GRN (TRANSFER SW POSTION) GRN/WHT IHT/BLU NERATOR -AILURE) LU/WHT IHT/ORG (ENGINE UNNING) )RG/WHT VHT/GRN 35% FUEL EMAINING) ;RN/WHT 9 SOLID WIRE 7 SOLID WIRE WHT/BLU ------- 1� B ;ENERATOR SOLID MINOR) WIRE BLU/WHT WHT (LEAK )ETECTED) ORG/WHT SYSTEM BLOCK 11 0 0 0 0 11 WHT/BLU 37 0 0 0 37 BLU/WHT 12 0 0 0 12 38 o a o 0 38 WHT/BLU BLU/WHT WHT/ORG ORG/WHT WHT/GRN GRN/WHT WHT/ORG ORG/WHT WHT/GRN GRN/WHT WHT/ORG ORG/WHT WHT/BLU BLU/WHT 17 0 0 0 —17' 43 0 0 0 43 ,a o 0 016 44 0 0 0 44 19 o 0 019 45 0 0 0 0 45 20 0 0 0 0 20 46 r o 0 0 46 21 o 0 0 21 477 o 0 0 47 22aoo-22 � o 0 0 4B 23� o 0 0 23 49 0 0 0 0 49 24 0 0 0 0 24 50 0 0 0 0 50 25 0 0 0 0 25 USER BLOCK 36 0 0 0 0 36 11 0 0 0 0 11 37 0 0 0 0 37 12 0 0 0 0 12 3B o 0 0 0 38 13 0 0 0 0 13 39 0 0 0 39 14 0 0 0 14 40 0 0 0 40 15 0 0 0 15 41 0 0 0 0 41 16 0 0 0 0 16 RECEIVE JUN 18 2007 CITY OF DEPT. MQ POWER ALARM WIRING - IDEN SCALE (24-X36': NOT TO SCALE ( SCALE (11'X17': NOT TO SCALE *rint. Together with NEXTEL ,m.s resa.s n ,c nm ,00 s[oweo, ■. noss M.o,.r azxsrs�rm PACIFIC TELECOM SERVICES, LLC see r,nn W. s, swi. eso rbT (zae) arz-soon rea (me) eoe-es,a 4072 - J i THOMAS R. HOLLAND STATE OF WASHINGTON i -, - :-_3 rY. z W mc, �z w 0Ua U �)L0 c4 w 1v V o E-2 MO POWER DIESEL GENERATOR ALARM WIRING — IDEN JOB # DRAWING WA0456 E-2 REVISION 0 ASCO 7000 SERIES TRANSFER SWITCH g BLK UTILITY POWER Ei WHT [OPTION 18G] (CLOSED WHEN POWER ON) 7 BLK 4 WHT 3 GRN GENERATOR POWER 9 RED [OPTION 18B] (OPEN WHEN POWER ON) 1 GRN 7 RED 31 BLU 32 BRN TRANSFER SWITCH POSITION (CLOSED FOR UTILITY) 12 BLU — 13 BRN aAE IX-6^4 r BLK WHT RED GRN BRN 5 BLU STRANDED WIRE BLK WHT RED GRN BRN 6 BLU STRANDED WIRE aD GND N Q O mGD ND O o 1n D_ O O t w t 0 GND MD it GND O O O V) D_ O t w t GND � w GND O O O V) D_ 0 t w t E aE GND Q 0 GND V) D_ O O t w t GND z) . GND O O Q 1n o NOTES: 1. SECOND POLYPHASER IS PROVIDED FOR ENVIRONMENTAL CONTROL SYSTEM (TO BE CONNECTED BY OTHERS). 2 POLYPHASERSALL SUFFIC ENT ROOM TO DO TH S THE CABINET. THE EXISTING TELCO RE POLYPHASER(S) SHOULD BE MOUNTED IS NOT W/IN A NEW 18"X18"X32" NEMA RATED ENLCOSURE MOUNTED ON THE EXISTING H-FRAME. 3. POLYPHASERS HAVE SPECIFIC WIRE IN/WIRE OUT ROUTING. THIS MUST BE FOLLOWED BY INSTALLATION PERSONNEL. 4_ POLYPHASER QUANTITY REQUIREMENTS. -COMA SITES RECEIVE 2, ONE MOUNTING PLANE FOR GENERATOR ALARMS ONLY. NO POLYPHASERS BETWEEN ATS AND BTS. -IDEN SITES RECEIVE 4, ONE MOUNTING PLANES, TWO FOR GENERATOR ALARMS, ONE FOR ATS ALARMS. -CO-HAB (IDEN AND COMA) RECEIVE 4, ONE MOUNTING PLANE, ALL GENERATOR ALARMS 00 TO THE IDEN SHELTER/CABINET, AND THE ATS ALARMS (FOR COMA ONLY) DO NOT REQUIRE POLYPHASERS - STRAIGHT THROUGH TO BTS (RADIO CABINET). -- IN CO-HAB INSTANCES 2 ATS WILL BE USED. THE IDEN ATS USES POLYPHASERS BETWEEN IT AND FINAL PUNCHDOWN. 5. ALL ALARMS GO TO THE IDEN SIDE ON COHAB SITES. ATS ALARMS ALSO GO TO THE COMA SIDE. NO POLYPHASERS ARE REQUIRED FOR HE ATS ALARMS FOR COMA. ATS ALARM WIRING - IDEN SCALE (24'X36'): NOT TO SCALE 2 SCALE: (11'X17': NOT TO SCALE WHT/BLU (UTILITY POWER) BLU/WHT WHT/ORG (GENERATOR POWER) ORG/WHT WHT/GRN GRN/WHT (TRANSFER SWITCH POSITION) 9 WHT/BLU SOLID BLU/WHT WIRE WHT/ORG ORG/WHT WHT/GRN GRN/WHT SYSTEM BLOCK 11 o O O o 11 37 0 0 0 37 12 o a o 12 38 0 0 0 0 38 21 0 0 0 0 21 47 o 0 0 47 22 2�=m 0 0 022 48 o 0 048 233 23 49 0 0 0 0 49 24 o I== 0 0 24 50 0 0 0 0 50 25 0 0 0 0 25 CABLE FROM TO MANUFACTURER PART NUMBER CONDUCTOR COUNT AND GAUGE USE NUMBER 2 (UNSHIELDED) ATS GENERATOR START GENERATOR 1 ATS BELDEN 8442 22 AWG SIGNAL TO GENERATOR TERMINAL STRIP GENERATOR SURGE 8 (UNSHIELDED) GENERATOR ALARMS TO SYSTEM 2 TERMINAL STRIP ARRESTORS BELDEN g421 22 AWG BLOCK SURGE ARRESTOR GENERATOR SURGE BELDEN 8442 2 (UNSHIELDED) FUSED 12 VDC TO SYSTEM BLOCK SURGE ARRESTOR 3 TERMINAL STRIP ARRESTORS 22 AWG GENERATOR SURGE 8 (UN2SHAIWGDED) ENERA O TO SYSTEM GENERATOR 4 TERMINAL STRIP ARRESTORS BELDEN 9421 SURGELARMS BLOCK ARRESTOR SURGE 8 (UNSHIELDED) ATS ALARMS TO SYSTEM BLOCK 5 ATS ARRESTORS BELDEN 9421 22 AWG SURGE ARRESTOR SURGE TELCO SUPERIOR 12-204-37 8 (SOLID CONDUCTOR) GENERATOR ALARM OUTPUTS FROM SYSTEM BLOCK SURGE ARRESTOR TO SYSTEM BLOCK 7 ARRESTORS BOARD / ESSEX 22 AWG TELCO S (SOLID GENERBLOCKATOR ALARM TS UTO IVGM E 8 ARSURGE RESTORS BOARD / ESSIOR EX 12-204-37 22CAWGUCTOR) SURGE ARRESTOR SURGE TELCO SUPERIOR 12-204-37 8 (SOLID CONDUCTOR) ATS ALARM OUTPUTS FROM SYSTEM BLOCK TO SYSTEM BLb-N O 9 ARRESTORS BOARD / ESSEX 22 AWG SURGE ARRESTOR {j ATS CABLE SCHED SCALE: (247(36'): NOT TO SCALE SCALE (I I'X17': NOT TO SCALE I CITY OF FEDERAL WA BUILDING PSP:�.Y Together with NEX[TEL neoxo +zs-2��.r.00 PACIFIC TELECOM SERVICES, LLC 3N FIM ev.w. 5., s,ul. e5o S . WA. W104 P,_ (2M) 342-9000 Fez (205) 903-5513 4072 THOMAS R. HOLLAND STATE OF WASHINGTON ' W 4 r Va a O N O C] z ZaD O 0 V a � Ll Q 70 wUJ W 0 Q o E-3 ATS CABLE SCHEDULE AND ATS ALARM WIRING — IDEN JOB # DRAWING 1 WA0456 E-3 REVISION 1 0 NOTES: 1. 2. 3. 4. 5. POLYPHASER SURGE PROTECTORS SHALL BE MOUNTED NEAR THE ATS AND CONNECTED TO NEAREST GROUND WIRE EXITING THE SHELTER WITH A #6 WIRE WITH A TWO HOLE LUG CONNECTION. ALL POLYPHASERS SHALL BE MOUNTED W/IN THE EXISTING TELCO CABINET. IF THERE IS NOT SUFFICIENT ROOM TO DO THIS, THE POLYPHASER(S) SHOULD BE MOUNTED W/IN A NEW 18"X1B"X12' NEMA RATED ENLCOSURE MOUNTED ON THE EXISTING H-FRAME POLYPHASERS HAVE SPECIFIC WIRE IN/WIRE OUT ROUTING. THIS MUST BE FOLLOWED BY INSTALLATION PERSONNEL POLYPHASER QUANTITY REQUIREMENTS; -CDMA SITES RECEIVE 2, ONE MOUNTING PLANE FOR GENERATOR ALARMS ONLY. NO POLYPHASERS BETWEEN ATS AND BTS. -IDEN SITES RECEIVE 4. ONE MOUNTING PLANES. TWO FOR GENERATOR ALARMS, ONE FOR ATS ALARMS. -CO-HAB ($DEN AND COMA) RECEIVE 4. ONE MOUNTING PLANE, ALL GENERATOR ALARMS GO TO THE IDEN SHELTER/CABINET, AND THE ATS ALARMS (FOR COMA ONLY) DO NOT REQUIRE POLYPHASERS -- STRAIGHT THROUGH TO BTS (RADIO CABINET). -- IN CO-HAB INSTANCES 2 ATS WILL BE USED. THE IDEN ATS USES POLYPHASERS BETWEEN IT AND FINAL PUNCHDOWN. ALL ALARMS GO TO THE IDEN SIDE ON COHAS SITES. ATS ALARMS ALSO GO TO THE COMA SIDE. NO POLYPHASERS ARE REQUIRED FOR THE ATS ALARMS FOR UTILITY CO. DISCONNECT L1 /L2 ✓GENERATOR ELECTRICAL GROUND II ✓EXOTHERMIC BOND TO EXTERIOR GROUND RING ! SHELTER DISCONNECT I I 1 F_71 N N I I I "CHASSISD H-FRAME) BOND CHASSIS BOND i ✓UTILITY ELECTRICAL GROUND ROD* ✓3 INCHES ABOVE SURFACE FOR INSPECTION ✓EXOTHERIC BOND TO EXTERIOR GROUND RING N ATS/MTS NORMAL CHASSIS BOND TO HALO (INTERIOR OR EXTERIOR (EXTERIOR) ✓SHELTER ELECTRICAL GROUND ROD* ✓3 INCHES ABOVE SURFACE FOR INSPECTION ✓EXOTHERMIC BOND TO EXTERIOR GROUND RING *IF UTILITY DISCONNECT 15FT OR LESS FROM SHELTER, COMMON ROD PERMITTED, OTHERWISE, TWO DISTINCT RODS. **BOND UTTUTTY DISCONNECT NEUTRAL/GROUND TO SHELTER GROUND IF UTILITY DISCONNECT IS WITHIN SHELTER PERIMETER, OTHERWISE, NOT BOND. NEUTRAL GROUND BOND SCALE (24"X36':NOT TO SCALE SCALE (11'X17-):NOT TO SCALE UTI LITY DISCONNECT EMERGENCY POWER INPUT FROM PADMOUNT GENERATOR I , I I I I I I I I GENERATOR CHARGE CONNECTION l E I ALARM /CONTROL CONNECTION I I I I I I I I I I I I GENERATOR APPLETON------_----- CONNECTOR ATS LOAD CENTER TO SITE LOADS I ' I I I I POWER I SURGE I .' ROTECTOR I k I I I TO FACILITY I ALARM ALARM BLOCK SURGE (PROVIDED PROTECTORS WITH SHELTER) I I� I I I I I I I I r----� NOTES: I ! I 1.IF PORTABLE IS REQUIRED IN ADDITION TO -�- I PADMOUNT GENERATOR, ADD PLANNING AS I I REQUIRED TO ADD MANUAL TRANSFER SWITCH I I AND APPLETON CONNECTOR IN EMERGENCY 1 # I BUS FROM ATS (SHOWN IN DOTTED LINES). I i L----J GENSE SINGLE -LINE DIAGRAM SCALE: (24"X36"): NOT TO SCALE 2 SCALE: (11"X17"): NOT TO SCALE ALL GENSET CONNECTIONS VIA STUB -UP AREA LOAD CENTER 1% �CHARGER HEATERS POWER L1 /L2 N I I I GENERATOR I GENSE-r POWER OUT CHASSIS BOND ALARM/STATUS/CONTROL TO HALO 3 TO C RING GENSET/TANK GROUND ROD SURGE SUPPRESSOR SITE LOAD CENTER SITE POWER UTILITY POWER IN ATS* I� UTILITY MAINS � ` DISCONNECT TO IMU MULTI -PAIR ALARM CABLE ALARM 66 BLOCK t CEIVE CONDUIT SINGLE -LINE SCALE: (24"X36"):NOT TO SCALE SCALE (11"X17': NOT TO SCALE JUN 18 2007 OF FFDEFtAL 1 *rint. )00 Together with NECra- lose WNOWS W NE SUITE IN IIEDWND. WA MOM PNONL' .'x+W IN PACIFIC TELECOM SERVICES, LLC screw WA. sell flimNr. (Doe) 312-sNN rs (DOS) sorest] THOMAS R. HOLLAND STATE OF WASHINGTON 1 1 � z Q 1 C✓ � :e �o 0 �O N o� 3z 0 0 Z > � O cv L O C] Cl w w Q o E-5 ELECTRICAL DETAILS JOB 4 DRAWING jl WA0456 E-5 REVISION 0 o. Federal Way 41k �pjG MASTER LAND USE APPLICATION 'Sly 1 DEPARTiVTENT QF CQMMiFNi7'S` DEVELOPMENT SERVICES - 33325 8s' Avenue South 2�07 PO Box 9718 3ut4 I S Federal Way WA 98063-9718 1�Y OF 253-835-2607;Fax 253-835-2609 c.F a1=1�AL WAS www.cityoffederalway.com BUlLD1NG p�,P APPLICATION No(s) G Date 6 l 1--0% Project Name Property Address/Location 174 Parcel Number(s) 2,92-16q'-979.-66 ` Project Description �Pr:,_ I to -s-Or c�-r �%m -ry e i/ �i t -h r �� r Wn J PLEASE PRINT Type of Permit Required Annexation Binding Site Plan Boundary Line Adjustment Comp Plan/Rezone Land Surface Modification Lot Line Elimination Preapplication Conference Process I (Director-s Approval) Process II (Site Plan Review) Process III (Project Approval) Process IV (Hearing Examiner's Decision) Process V (Quasi -Judicial Rezone) Process VI SEPA w/Project SEPA Only Shoreline: Variance/Conditional Use Short Subdivision Subdivision Variance: Commercial/Residential Required Information 9C_ Zoning Designation Comprehensive Plan Designation _Value of Existing Improvements Value of Proposed Improvements International Building Code (IBC): Js� C1 C_ vP `L c` Occupancy Type 1 Construction Type -14A Applicant }} 4 Name: M, Address: 56 9 f S ` A,., City/State: Su- l c lr✓Q zip: "f91& 1 , Phone: 2 o G- 31 ❑ _Z 21 z; Fax: 24,6 �o"j_ ,SS 13 t.✓o� . G cJ l�r-1 Email: r)-1 er-3 i z-5 L / Signature: �� Agent (if different than Appli Name: Address: City/State: Zip: Phone: Fax: Email: Signature: Owner Name: l l t>i d I- E, 5!, 11 4- Address: l L4 ( S. 'zl5G _, City/State: F,�cr.t � �an 7 zip: 1&ba3 Phone: oG Ve- Z 2 Fax: Email: Signature: Bulletin #003 -August 18, 2004 Page 1 of 1 k:\Handouts\Ivlaster Land Use Application CITY OF FEDERAL WAY DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES DEVELOPMENT REVIEW COMMITTEE TRANSMITTAL DATE: June 22, 2007 TO: Will Appleton, Development Services Manager Scott Sproul, Assistant Building Official Brian Asbury, Lakehaven Utility District Chris Ingham, Federal Way Fire Department FROM: Laura Kim FOR DRC MTG. ON: FILE NUMBER(S): 07-103303-00-UP RELATED FILE NOS.: None PROJECT NAME: SPRINT/NEXTEL @ ENCHANTED PKWY PROJECT ADDRESS: 1741 S 356TH ST ZONING DISTRICT: BC PROJECT DESCRIPTION: Sprint to install an emergency generator on an existing concrete slab inside an existing fenced compound LAND USE PERMITS: Use Process I PROJECT CONTACT: PACIFIC TELECOM SERVICES MATT ENGLESBY 568 1ST AVE S Suite 650 2067191639 (Work) MATERIALS SUBMITTED: Plan Sheets T-1 thru E-5 Project Description Master Land Use Application Pacific Telecom Services, LLC June 18, 2007 Department of Community Development 33325 8th Ave S. Federal Way, WA 98063-9718 SUBJECT: City of Federal Way Land Use Process I permit of the installation of an emergency generator Dear Planning Department, This letter is to describe the Sprint Nextel emergency generator proposal. Sprint Nextel proposes to install an emergency generator inside of an existing fenced wireless communication compound. The site address is 1741 S. 356b St, Federal Way, WA 98003, parcel # 282104-9178-06. The project consists of placing a 40kw desiel powered generator on an existing concrete slab inside of an existing fenced area. The property is owned by Lloyd Russell and the current use is a wireless communication facility. If you have any questions or need additional information please contact me. Sincerely, Matt Englesby Pacific Telecom Services 568 lst Ave S. #650 Seattle, WA 98104 menglesby a&tswa.com 206-310-2290 RECEIVE JUN 1 8 2007 CITY AY LOING DEPT. 568 V Avenue, S, #650, Seattle, Washington 9804 • (Phone) 206.251.6384 • [Fax] 206.903.8513 0 www.ptswa.com